ADP15 Process Input Digital Indicator / Display (Panel Mount)

ADP15 Process Input Digital Indicator / Display (Panel Mount)
ADP15
Versatile Indicator/Controller
Features
Input Types for all Industry Standard Sensors
High Resolution
Very High Reliability
Small Panel Space
Easy Access to Electronics via front of panel
Measurement in Any Engineering Units
Full calibration & programming via keypad or comms import
Peak hold
Isolated inputs & outputs
PID control
Analogue outputs to all industry standards
Relays – High current
Printer Drive
Pre calibrated inputs
10 year data protection
3 year guarantee
DC power options
Communications – RS232, RS485/422
Specifications
Inputs
Input type
DC Voltage
DC Current
AC Voltage
AC Current
Temperature
Strain Gauge
Potentiometer
LVDT
Pulse
Angle
Dual DC
Input ranges available
+/-20mV, +/-200mV, +/-2V,+/-20V, +/-200V
+/-2mA, 4-20mA, +/-20mA, +/-200mA
0-200mV, 0-2V, 0-20V, 0-200V
0-1A
Platinum Pt100, Thermocouples K, J, R, S, T, B, N, E
Resistive bridge settable +/-0.5 to +/-200mV/V, Excitation 10Vdc
Any value in the range 100R to 10K
AC excitation with signal selectable 20mV to 10V full range
Speed, rate or total, 30 to 200,000rpm, 0.3u Secs to 200 Secs.
Quadrature shaft encoder
2 inputs of 4-20mA or 0-10V allowing AxB, A-B, A+B, A/B, B=set point
DC Analogue Outputs
Order Code
V1
V2
V3
V4
V6
Max Current out 50mA
Range
0 to 1V
0 to 5V
1 to 5V
0 to 10V
-10 to +10V
Accuracy, typical ± 0.08% of output, ± 0.08%FSD
Resolution, as display resolution, max 15 bits
Calibration, by 15-turn pre sets for gain and offset
Inversion, By keypad value
Order Code
A1
A2
A3
A4
A5
Max Voltage out 20V
Range
0 to 1mA
0 to 20mA
4 to 20mA
10 to 50mA
0 to 5mA
Isolation, ±130V RMS or DC max to analogue input or to any other port
Ranging, Fully keypad scalable over desired display range
PID, Power level, when selected = 12 bit resolution output
Communication Port CP Operation
All ADP15 display data can be accessed via the communications port along with relay, PID power and EEPROM status.
All ADP15 user configurable data can be changed including EEPROM enable/disable and relay reset (ADP15 address code cannot be changed).
Communications Port
Order Code
Type
Details
COM1
RS232
For printer or direct connection to 1 device, 3 wire
COM1
RS485/422
For up to 32 instruments on 1 bus, 4 wire
S1
20mA
For up to 25 instruments per interface, 4 wire
Baud rates, 300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only)
Electrical isolation, ±130V RMS or DC max to analogue input or any other port
Formats, MODBUS RTU, MANTRABUS and printer output formats
ADP15 Product Sheet
Issue 1.9 13.04.06
Specifications
Alarm/Control Outputs
Type
Function
Order Code
SPCO
1 relay on SP1
R1
DPCO
1 relay on SP1
R2
R3
SPCO
2 relays on SP1& 2
R4
SPCO
1 relay on SP2
R5
DPCO
1 relay on SP2
Relays, 230V at 5A AC resistive
Isolation, ±130V RMS
Keypad Programmable options: Hysteresis, Latching, Output Inversion, Delay Times, PID values and Time Proportioning.
16 relay option can be supplied on external DIN rail modules (10A SPCO). Available for DC, AC, Temperature, Strain Gauge & Potentiometer inputs, ask for ADP15-SP16
Power Supplies
Order Code
240
110
12/24
Type
220V-230V AC 50-60Hz 10W
110V-120V AC 50-60Hz 10W
9-32V DC 10W isolated
Base ADP15
Input Filter
Displays
Update Rate
Programmable to average up to 64 display updates.
7 segment LED 4.5 digit 10mm.3 x 3mm LED's 2 for relay status, 1 for program and hold indication.
Up to 10 updates per second
Controls
4 membrane panel keys with tactile feedback. 1 scroll key to view/update parameter. 1 digit select key. 1 digit increment key. 1 reset key. Keypad disable by internal
links behind front panel. Hold function by digit select key when in input mode.
Data Retention/Protection
Retention:
Protection of data
and function(s):
10 years for set up values, minimum of 100,000 write cycles.
Watchdog timer giving repeat auto resets. Impending power detection and hold off. Keypad security
and time out.
CE & Environmental
Storage temperature
Operating temperature
Relative humidity
Safety/Low Voltage Directive
EMC Directive
-20 to +70ºC
-10 to 50ºC
95% maximum non condensing
73/23/EEC amended by 93/68/EEC
BS EN 61010-1:2001, IEC 1010-1-1990
89/336/EEC
Basic Standard BS EN 61326:1998
EMC Emissions
BS EN 55011:1998
EMC Immunity
BS EN 61000-4-2:1995
BS EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:2004
Other Options & Accessories
Panel Mounting or Din Rail Mounting
One pass calibration
20mA PC Communications Interface (IF25)
VisualLink PC SCADA Software
Analogue Totaliser (Integrator)
Physical
Case Dimensions
Case Material
Weight
Terminals
Accessibility
DIN 72 x 72 x 163mm (excluding mounting terminal)
Grey Noryl, flame retardant
750 grams
2.5mm, saddle field terminals
All electronics removable through front panel leaving field wiring and case in situ.
Panel Cut Out
All dimensions are in millimetres
C
In the interest of continued product development, Mantracourt Electronics Limited reserves the right to alter product specifications without prior notice.
ADP15 Product Sheet
Issue 1.9 13.04.06