automated tuner system power distribution hubs

automated tuner system power distribution hubs
Series
MT1020A & B
MAURY MICROWAVE
C O R P O R A T I O N
07 July 2006
AUTOMATED TUNER SYSTEM
POWER DISTRIBUTION HUBS
Models MT1020A and MT1020B
MT1020A
Features
• Integrated Solid State and
Electro-Mechanical Tuner Control Hubs
• Enhanced Speed
• Integrated Tuner DLL
• Super Stable Mechanical Design
MT1020B
• Ideal for On-Wafer Load Pull and Noise
Parameter Measurements
• Compatible with ATN NP and LP Systems
Description
both 2.0 and 1.1 USB standards. The MT102B
automated tuner system power distribution hub will
not operate Maury or ATN solid state tuners.
The Maury model MT1020A SmartHub is designed to
provide a USB 1.1 interface to Maury MT97xU and
MT98xU series USB controlled mechanical, and
Maury or ATN NP5 and LP series solid state tuners. It
supplies all of the power requirements, including
motor drive current for up to nine tuners, or other
USB compatible devices. The LED readout and mode
selection keys on the front panel of the SmartHub are
used to display information about the tuners or other
devices connected to each port.
Accessories Supplied
The MT1020B ATS Power Distribution Hub is
designed to provide an economical, convenient
connection and fast interface for use with Maury ATS
USB controlled automated mechanical tuners. It
contains a switching power supply and a four-port
USB 2.0 hub. It connects to the host computer via a
standard USB 2.0 interface and is compatible with
(GMC-3A, Time Lag)
2900 Inland Empire Blvd. • Ontario, California 91764-4804
Tel: 909-987-4715 • Fax: 909-987-1112 • http://www.maurymw.com
Copyright 2006 Maury Microwave Inc., all rights reserved.
The MT1020A automated tuners are provided with:
• MT1020S5 USB tuner cable assembly which
connects the tuner to the MT1020A SmartHub
The MT1020B automated tuners are provided with:
• MT1020S1 operating manual
• Spare fuse, Maury P/N 499-F-107
• Power cord: For 115VAC,
P/N 499-C-082 (U.S.A.) or for 230 VAC,
P/N 499-C-469 (Europe, CE certified) or
P/N 499-C-718 (Chinese, CCC certified)
• USB cable assembly, P/N 499-C-722
technical
data
4T-068
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 1 of 3
07 July 2006
Specifications for the MT1020A
Specifications for the MT1020B
Automated
USB Tuners .................... Maximum of 9 USB controlled
microwave tuners
Automated
USB Tuners .................... Maximum of 4 USB controlled
microwave tuners
USB Interface ......................................... 1.1 compatible
USB Interface ............................ 1.1 and 2.0 compatible
Power Requirements .............................. 85 to 264 VAC
47 to 500 Hz, 10 Amps maximum
Maintains supply voltage
fluctuations not exceeding
± 10% of the nominal
voltage. Transient overvoltages
according to overvoltage category II
Power Requirements ........................... 100 to 264 VAC,
47 to 63 Hz, 3A
Maintains supply voltage
fluctuations not exceeding
± 10% of the nominal
voltage. Transient overvoltages
according to overvoltage category II
Output Power ................................. +5 Vdc at 20 Amps
+12 Vdc at 4.2 Amps
+15 Vdc at 6.7 Amps
+24 Vdc at 20.8 Amps
+48 Vdc at 1 Amp
Output Power ............................ +5 Vdc at 5 Amps and
+24 Vdc at 3.4 Amps
USB Power ......................... +5 Vdc at 500mA per port.
(With MT1020A connected to an
AC power source and with the
MT1020A power switch set to
the ON position.)
Environment ..................................... Relative humidity,
90% non-condensing.
Indoor use only.
Altitude up to 2000M
Pollution degree 2
4T-068
technical
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 2 of 3
data
USB Power ......................... +5 Vdc at 500mA per port.
(With MT1020B connected to an
AC power source and with the
MT1020B power switch set to
the ON position.)
Environment ..................................... Relative humidity,
90% non-condensing.
Indoor use only.
Altitude up to 2000M
Pollution degree 2
2900 Inland Empire Blvd. • Ontario, California 91764-4804
Tel: 909-987-4715 • Fax: 909-987-1112 • http://www.maurymw.com
07 July 2006
MAURY MICROWAVE
C O R P O R A T I O N
Dimensions for the MT1020A – Inches (mm)
Top View
Model MT1020A
SmartHub
Dimensions are shown
in inches and [mm]
17.56 [446.0]
14.74 [374.5]
19.02 [483.0]
3.72 [94.4]
I
O
Front View
Side View
Rear View
Dimensions for the MT1020B – Inches (mm)
Top View
Model MT1020B
ATS Power Distribution Hub
Dimensions are shown
in inches and [mm]
10.13 [257.2]
I
12.35 [313.6]
4.28 [108.6]
O
LINE
Front View
Side View
2900 Inland Empire Blvd. • Ontario, California 91764-4804
Tel: 909-987-4715 • Fax: 909-987-1112 • http://www.maurymw.com
Copyright 2006 Maury Microwave Inc., all rights reserved.
technical
Rear View
data
4T-068
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page 3 of 3
Was this manual useful for you? yes no