HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
Heading
Product Name
A Higher Level of Performance
Data Sheet
HAWK Magnetostrictive Level Transmitter
(CSA/FM, ATEX)
For more information, please visit >
www.hawkmeasure.com
>
HAWK Magnetostrictive Level Transmitter
(CSA/FM, ATEX)
Overview
Model HLT Transmitter with Analog Output and HART
(CSA/FM, ATEX)
Product overview
The Model HLT liquid level transmitter satisfies the demand for an analog communication interface for
sightglass (bypass chamber) applications. The Model HLT transmitter provides a 4-20 mA output for most
magnetic level gauge manufacturers and allows for mounting external to the chamber without interrupting
the process.
Model HLT transmitters are modular in design offering a selection of mounting options and pipe styles.
The modularity also offers simple field replacement. Subject to local electrical codes, the sensing element
and electronics can be removed from the transmitter pipe without disturbing the operation of the process
saving both time and money.
The model HLT transmitter uses HART communication for setup, calibration, and diagnostics. HART
can be utilized via a hand-held communicator or with the HAWK setup software via a PC and HART
to serial converter. The optional on-board display and keypad is also provided for local indication and
programming.
Features
Applications
Markets
• 4 to 20 mA Analog Output with HART®
• Inventory Control
• Petroleum and Petrochemical
• No Scheduled Maintenance or Recalibration
• Process Vessel
• Power Generation
• High Accuracy and Repeatability
• Bypass Chamber
• Specialty Chemical
• AMS Aware
• Explosion-proof and/or Intrinsically Safe
All specifications are subject to change. Contact HAWK for specifications and engineering drawings that are critical to
your application. Drawings contained in this document are for reference only.
•
2
>
<
HAWK Magnetostrictive Level Transmitter
(CSA/FM, ATEX)
Overview
Level Plus ® Model MRA3/4 ProductSpecifications
PRODUCT DATA SHEET
Product specifications
Product specifications
Parameters
Parameters
Specifications
Specifications
ENVIRONMENTAL
LEVEL OUTPUT
Measured
variable:
Total Level or Interface Level
Product level
Output signal /
Protocol:
4 to 20 mA with HART®
Order length:
Rigid pipe: 508 mm (20 in.) to
Enclosure rating:
NEMA Type 4X
Humidity:
0 to 100% relative humidity,
non-condensing
Operating
temperatures:
Electronics:
-40 °C (-40 °F) to 71 °C (160 ºF)
Sensing element:
-40 °C (-40 °F) to 125
150 °C (257 °F) ◊
3658 mm (144 in.) § ∆
∆ Contact factory for longer lengths.
§ Order length equals the measurement range plus
the inactive zone.
Higher temperatures are available using a small insulation pad.
◊. Contact factory for specific temperature ranges.
FIELD INSTALLATION
Housing
dimensions:
Non-linearity:
0.02% F.S. or 0.794 mm (1/32 in.) *
MOUNTING
* Whichever is greater
Repeatability:
Rigid pipe:
0.01% F.S. or 0.381 mm (0.015 in.) *
(any direction)
Connections:
>
2-wire shielded cable twisted pair,
<
ELECTRICAL CONNECTIONS
COMPATIBILI TY
HAWK
K-Tek
Jerguson
Kenco
Wika
Klinger
Quest-Tec
Dual
Compartment
Housings:
3/4 in.opening,
conduit opening,
ATEX Version
Single
Cavity:
¾ in. conduit
M20M20
for for
ATEX
Single Cavity: 3/4 in. conduit
opening, M20 for ATEX Version
version
Vize
Penberthy
Others
DISPLAY
ELECTRONICS
Input voltage:
10.5 to 36.1 Vdc, 28 Vdc
maximum for I.S. ATEX approval
Fail safe:
High (21.4 mA), or Low (3.8 mA)
Reverse polarity
protection:
Series diode
Lightning/
Transient
protection:
Hose clamp to chamber
WIRING
† Contact factory for alternative materials.
MRA3/4 chamber
compatibility:
Single cavity:
127 mm (5 in.) by 123 mm (4.85 in.)
121 mm (4.75 in.) O.D.
Measured
variables:
Product level
Size:
13 mm (0.5 in.)
Number of digits:
16
Stage 1:
Line-to-ground surge suppression;
IEC 61000-4-5
Stage 2:
Line-to-line and line-to-ground transient
suppressors; IEC 61000-4-4
CALIBRATION
Zero adjust
range:
Anywhere within the active length
Span adjust
range:
Full scale to 152 mm (6 in.) from zero
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog Output
Product Data Sheet, Part No.: 551252, Revision A 01-11
3
2
MTS Sensors
HAWK Magnetostrictive Level Transmitter
(CSA/FM, ATEX)
Overview
PrODuCt Data sHeet
Level Plus® Model Mra3/4 agency approvals
setup software and Programming
Agency Approvals
agency approvals
explosion proof
FM 3615
C22.2 No. 30
Intrinsically safe
Class I, Division 1, Groups B, C and D ••∆
Class II, Division 1, Groups E, F and G ••
Division 1, NEMA Type 4X
FM 3610
C22.2 No. 157
Class I, Division 1, Groups A, B, C and D
Class II, Division 1, Groups E, F and G
Class III, T4
Division 1, NEMA Type 4X
•• Explosion-proof housing required
∆ 90° electronic mount is only for Groups C and D
eN 50020
PTB 00 ATEX 2069X
II 1/2 G bzw. II 2 G
EEx ia IIB T4 bzw. EEx ia IIA T4
Mts analog setup software
HART ART® handheld communicator programming
Hart® handheld communicator programming
MTS has developed the MTS Setup Software to help customers
Theprogram
Model and
HLTcustomize
transmitter
programming
can
also
be
performed
by
using handheld HART communicator device such as the
their Level Plus Model MRA3/4 transmitter.
The Level Plus Model MRA3/4 transmitter programming can also be
Rosemount® 375 or 475.
The Model MRA3/4 transmitter is programmed through the HART
performed by using handheld HART communicator device such as
interface.
This
interface
is
easily
connected
to
a
PC
by
using
the
the Rosemount® 375 or 475.
Setpoint programming using the display
HART-to-Serial converter. The MTS Analog Setup Software allow
display
user to
adjust
both ‘Zero’
(4 is
mA)
and ‘Span’with
(20 mA)
setpoints,
Anythe
Model
HLT
transmitter
that
purchased
a display
has thesetpoint
ability toprogramming
adjust the 4using
and the
20 mA
setpoints by pressing the
adjust HART parameters, and customize the optional built-in display.
Any Level Plus Model MRA3/4 transmitter that is purchased with a
appropriate button located at the bottom of the display.
MTS setup software is shipped with each transmitter order. However,
display has the ability to adjust the 4 and 20 mA setpoints by pressing
if you require an additional copy or an upgrade to your previously
the appropriate button located at the bottom of the display.
installed setup software, software is available for download. Refer to
the MTS Level Products page at http://www.mtssensors.com
MTS Sensors
4
3
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog Output
Product Data Sheet, Part No.: 551252, Revision A 01-11
HAWK Magnetostrictive Level Transmitter
(CSA/FM, ATEX)
Overview
Product dimensions and mounting
HAWK offers the Model HLT transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see ‘Figure 1’). The
Model HLT can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144
in.). Stainless steel hose clamps are typically used to secure the Model HLT to the MLG.
The Model HLT transmitter ‘Measuring Range’ is equal to the ‘Order Length’ minus the ‘Inactive Zone’. The ‘Measuring Range’ should
equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model HLT on the
MLG.
132 mm
(5.19 in.)
Current Pulse
Start pulse
>
Magnetic
203.2 mm
(8 in.)
Float Assembly
Sensor
Wire
Inactive Zone
95.3 mm (3.75 in.)
Measuring
Range
Order
length
Inactive Zone
76.2 mm (3 in.)
Figure 1
5
<
HAWK Magnetostrictive Level Transmitter
(CSA/FM, ATEX)
Overview
Product dimensions and mounting
HAWK offers the Model HLT transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see ‘Figure 2’). The
Model HLT can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144
in.). Stainless steel hose clamps are typically used to secure the Model HLT to the MLG.
PrODuCt Data sHeet
Level
The Model HLT offers an optional 90 degree fitting for an MLG with both top and bottom flanges. The 90 degree fitting allows the typical Insta
electronic head of the Model HLT to be Product
positioneddimensions
to the side of the
allowing for simpler mounting.
andpipe
mounting
MTS offers
the Level
Plus
ModelLength’
MRA3/4minus
transmitter
configured
for external
mounting toRange’
most Magnetic
The Model HLT transmitter ‘Measuring Range’
is equal
to the
‘Order
the ‘Inactive
Zone’.
The ‘Measuring
shouldLevel Gaug
The Model MRA3/4 can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm
equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model HLT on the
(144 in.). Stainless steel hose clamps are typically used to secure the Model MRA3/4 to the MLG.
MLG.
The Model MRA3/4 offers an optional 90 degree fitting for an MLG with both top and bottom flanges. The 90 degree
electronic head of the Model MRA3/4 to be positioned to the side of the pipe allowing for simpler mounting.
The Model MRA3/4 transmitter ‘Measuring Range’ is equal to the ‘Order Length’ minus the ‘Inactive Zone’. The ‘Mea
equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the M
MLG.
>
<
2
ft.
9
6
3
1
ft
9
6
3
0
Figure 2. Model MRA3/4
mounting,
top and bottom flange
Figure
2
6
HAWK Magnetostrictive Level Transmitter
(CSA/FM, ATEX)
Overview
Model Mra3/4 Liquid-Level transmitter
Ordering information - FM and Csa approvals
PrODuCt Data sHeet
Ordering information for FM-CSA approvals
Ordering information for FM-Csa approvals
traNsMItter MODeL
M
=
=
=
=
=
4-20 mA Single loop with Display , with HART
4 =
=
Single cavity (explosion-proof and intrinsically safe)
a
3
=
=
5
= 90° fitting, housing bottom left
6
= 90° fitting, housing bottom right
3
=
90° fitting, housing top left
=
90° fitting, housing top right
traNsMItter PIPe
=
=
D
cavity
withwith
display
(explosion-proof
and intrinsically
safe)
D ==Single
Single
cavity
display
(explosion-proof
and intrinsically
E = Dualsafe)
cavity with display (explosion-proof and intrinsically safe)
Integral electronics
4
B
2
Industrial pipe, 5/8 in. OD
=
r =
4
4-20 mA Single loop no display , with HART
eLeCtrONICs MOuNtING
1
r
=
HOusING tyPe
B
=
24 Vdc, 2-wire loop
OutPut
3
1
Analog output liquid-level transmitter
INPut POWer
a
M
Magnetostrictive transmitter
tyPe
r
=
5
6
7
>
8
<
Industrial pipe, ½ in. OD
MaterIaLs OF CONstruCtION (WetteD Parts)
=
Note: contact factory for other materials
1
=
316L stainless steel
PrOCess CONNeCtION tyPe
X
=
X
=
0
=
M
=
=
PrOCess CONNeCtION sIZe
=
10
Sightglass
teMPerature
=
11
None
uNIt OF MeasureMeNt
Metric (millimeters) Encode length in millimeters if using metric
(XXXXX mm)
=
u =
LeNGtH
=
9
Sightglass
12
US Customary (inches) Encode length in inches if
ordering in US Customary (XXX.XX in.)
=
13-17
Order length based on unit of measurement
Rigid/Sanitary transmitter: 508 mm (20 in.) to 3658 mm (144 in.)
sPeCIaL
s
=
Standard product
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog Output
Product Data Sheet, Part No.: 551252, Revision A 01-11
7
=
e =
6
18
Engineering special
(not affecting agency controlled parts or features)
MTS Sensors
HAWK Magnetostrictive Level Transmitter
(CSA/FM, ATEX)
Overview
PrODuCt Data sHeet
Model Mra3/4 Liquid-Level transmitter
Ordering information - ateX approval
Ordering information for ATEX approval
Ordering information for ateX approval
traNsMItter MODeL
M
=
tyPe
r
=
a
=
4-20 mA Single loop with display , with HART
=
G
=
SIngle cavity (ATEX IIA)
J
=
Single cavity with display (ATEX IIA)
1
=
4
HOusING tyPe
=
=
=
=
MTS Sensors
8
5
6
7
>
8
<
9
10
Sightglass
=
11
None
=
u =
Metric (millimeters) Encode length in millimeters if using metric
(XXXXX mm)
12
US Customary (inches) Encode length in inches if ordering
in US Customary (XXX.XX in.)
=
13-17
Rigid or Sanitary transmitter: 508 mm (20 in.) to 3658 mm (144 in.)
sPeCIaL
s
4
Sightglass
LeNGtH (Order length based on unit of measurement)
=
=
=
uNIt OF MeasureMeNt
M
=
=
teMPerature
0
3
Stainless steel, 1.4404
PrOCess CONNeCtION sIZe
=
a
r = Industrial pipe, ½ in. OD
Industrial pipe /8 in. OD
PrOCess CONNeCtION tyPe
X
=
=
5
MaterIaLs OF CONstruCtION (WetteD Parts) (Note: contact factory for other materials)
=
2
Integral electronics
traNsMItter PIPe/HOse
X
r
= 4-20 mA singlel loop no display , with HART
R = Single cavity (ATEX IIB)
r = SIngle cavity (ATEX IIB)
T = Single cavity with display (ATEX IIB)
t = Single cavity with display (ATEX IIB)
E = Dual
cavity with display (explosion-proof and intrinsically safe)
eLeCtrONICs MOuNtING
=
=
=
3
1
1
24 Vdc
OutPut
=
M
Analog output level transmitter
INPut POWer
B
=
Magnetostrictive transmitter
Standard product
=
e
=
18
Engineering special (not affecting agency controlled parts or features)
7
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog Output
Product Data Sheet, Part No.: 551252, Revision A 01-11
HAWK Magnetostrictive Level Transmitter
(CSA/FM,
ProgrammingATEX)
and hardware accessories
Level Plus® Model Mra3/4 accessories
Programming and Hardware
Overview
PrOGraMMING aCCessOrIes
Part NuMBer
M-series Model Mra3/4
PC setup software on CD
Includes HART adapter, part no. 380068
252273-1
M-series Model Mra3/4
PC setup software on CD
252273-2
Programming and hardware accessories
HARDWARE
HarDWare
PART
PartNUMBER
NuMBer
Hart to rs-232 adapter
(SMAR H1-311)
380068
>
<
FM
APPROVED
Part Number: 551252 revision a 01-11
MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation.
All other trademarks are the property of their respective owners.
All Temposonics sensors are covered by US patent number 5,545,984. Additional patents are pending.
Printed in USA. Copyright © 2011 MTS Systems Corporation. All Rights Reserved in all media.
®
seNsOrs
Mts systems Corporation
sensors Division
Mts sensor technologie
GmbH & Co. KG
Mts sensors technology
Corporation
3001 Sheldon Drive
Cary, North Carolina
27513, USA
Tel.: +1-800-633-7609
Fax: +1-919-677-2343
+1-800-498-4442
e-mail: sensorsinfo@mts.com
http://www.mtssensors.com
Auf dem Schüffel 9
D - 58513 Lüdenscheid, Germany
Tel.: +49-2351-9587-0
Fax: +49-2351-56491
e-mail: info@mtssensor.de
http://www.mtssensor.de
737 Aihara-cho, Machida-shi
Tokyo 194-0211, Japan
Tel.: +81-42-775-3838
Fax: +81-42-775-5516
e-mail: info@mtssensor.co.jp
http://www.mtssensor.co.jp
FM
APPROVED
Part Number: 550677 Revision J 01-11, 02-11
MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their
respective owners. Printed in USA. Copyright © 2011 MTS Systems Corporation. All Rights Reserved in all media.
9
All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings
contained in this document are for reference only. Go to http://www.mtssensors.com for the latest support documentation and related media.
HAWK, Since 1988
Hawk Measurement Systems Pty Ltd (HAWK) was established
in 1988. It's founding members saw the universal requirement
of various industries requiring improved process control and
efficiency in their operations.
We Can Help
HAWK understands the difficulties customers face when seeking
accurate level measurement. Every application is different,
involving a multitude of environmental factors. This is where
HAWK excels. Our aim is to ensure that customers not only feel
comfortable with our technology, but that we also to ensure a
consistent and reliable solution is in place for the long term. We
believe that a combination of application and product expertise,
as well as forward thinking and proactive support policies are the
foundation of successful customer-supplier relationships.
10
>
<
Overview
Progressive Technical Support
HAWK believes that the future of the Level Measurement Industry
revolves around the quality of pre and post sales - support. Our
aim is for all sales & support staff to be product experts, and
more importantly application experts making our customers
applications as efficient and consistent as possible.
Remote Innovation
HAWK understands the need for immediate technical assistance.
The HAWKLink 3G communication device allows any computer
with internet access and our free GosHawK diagnostic &
calibration software; to dial in, calibrate, test, and check the
performance of HAWK products. This innovative system allows
our Global Support Team to assist with commissioning and after
sales service of HAWK equipment worldwide. Measurement
problems are addressed as they happen; not days or weeks later.
Knowledge Sharing
HAWK believes that knowledge sharing is key to creating long
term relationships. Empowering our customers and our worldwide
distribution network, whilst being available at all times to lend a
helping hand, is the perfect recipe for long term solutions and
relationships. HAWK openly extends an invitation to share our 25
years of level measurement experience, and ensure that your day
to day processes are efficient, understood, and always working.
11
>
<
<
A Higher Level of Performance
Hawk Measurement Systems
Hawk Measurement
(Head Office)
7 River Street
Middleton, MA 01949, USA
15 - 17 Maurice Court
Nunawading VIC 3131, AUSTRALIA
Phone: +61 3 9873 4750
Fax: +61 3 9873 4538
info@hawk.com.au
Phone: +1 888 HAWKLEVEL (1-888-429-5538)
Phone: +1 978 304 3000
Fax: +1 978 304 1462
info@hawkmeasure.com
For more information and global representatives: www.hawkmeasure.com
Additional product warranty and application guarantees upon request.
Technical data subject to change without notice.
Represented by:
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising