Residential Power Vent Gas Water Heater

Residential Power Vent Gas Water Heater
Residential Power Vent
Gas Water Heater
Photo is of
RG2PV50H6N
FEATURING:
The TTW ® Models Feature:
■ ENERGY STAR® Qualified—Some models qualify for the September 1, 2010
minimum ENERGY STAR® EF requirement, as well as most utility rebate programs.
■ Bradford White ICON System™—Intelligent gas control with spark to pilot ignition
system eliminates the constant burning pilot. This results in savings of pilot gas during
standby periods (120 V.A.C.).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Delivery
ratings and tighter temperature differentials.
-- Advanced Temperature Control System—Microprocessor constantly monitors and
controls burner operation to maintain consistent and accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during
start-up and provides ten different diagnostic codes to assist in troubleshooting.
■ Power Vented Water Heater—Designed for installations where atmospheric units
cannot be used. Exhaust gases are vented under positive pressure directly out of the
building through the roof or the wall.
■ Powerful Blower Motor—Our significantly quiet design has greater resistance to
outside winds and the power to vent in many difficult venting situations.
-- Ten Foot Power Cord—Included (120 VAC).
■ Horizontal and Vertical Venting—PVC, ABS or CPVC (Maximum equivalent vent
length on reverse side).
■ Advanced ScreenLok® Technology Flame Arrestor Design—Flame arrestor is
designed to prevent ignition of flammable vapor outside of the water heater (excluding
RG1PV55H6N & RG2PV75H6N).
■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if flammable
vapors are detected. The sensor will also prevent operation if there is ongoing
flammable vapor burn inside the combustion chamber (excluding RG1PV55H6N &
RG2PV75H6N).
■ Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is
required under normal conditions (excluding RG1PV55H6N & RG2PV75H6N).
■ Sight Window—Offers a view into the combustion chamber to observe the operation
of the pilot and burner.
■ Factory-Installed Hydrojet® Total Performance System—Sediment reducing device
that also increases first hour delivery of hot water while minimizing temperature buildup in tank.
■ Vitraglas® Lining—An exclusively engineered enamel formula that provides superior
tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®)
is fused to the steel surface by firing at a temperature of over 1600°F (871°C).
■ Insulation System—Non-CFC foam covers the sides and top of the tank, reducing
heat loss. This results in less energy consumption, improved efficiencies, and jacket
rigidity.
■ Water Connections—3⁄4" (19mm) NPT factory-installed true dielectric fittings extend
water heater life and simplify water line connections.
■ 3/4" (19mm) NPT Side Connections—(RG2PV50H6N, RG1PV55H6N, and
RG2PV75H6N only).
■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat
loss in piping and eliminates the potential for noise generation.
■ Protective Magnesium Rod—(RG1PV55H6N has 2).
■ T&P Relief Valve—Installed.
■ Thermostatic Mixing Valve (ASSE Approved)—Included (RG1PV55H6N only).
■ Low Restriction Brass Drain Valve—Durable tamper-proof design.
6 or 10-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526;
6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984;
8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS:
2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System®, ScreenLok®, TTW®, Vitraglas® and Hydrojet® are registered
trademarks of Bradford White® Corporation.
1261-B-1216
Residential Power Vent Gas Water Heater
Power Vent Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
RG1PV40S6N
RG1PV50S6N
★ RG2PV40S6N
★ RG2PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
Capacity
Recovery at
90°F Rise*
Nat.
LP
Nat. Nat. LP LP
1st Hour
U.S. Imp. BTU/Hr. BTU/Hr. Rating Energy U.S. Imp. U.S. Imp.
Gal. Gal. Input
Input
(Gal.) Factor GPH GPH GPH GPH
40
50
40
50
40
50
48
55
75
33
42
33
42
33
42
42
46
62
40,000
40,000
40,000
40,000
40,000
40,000
65,000
78,000
76,000
72
86
72
84
72
86
112
N/A
N/A
38,000
38,000
38,000
38,000
40,000
40,000
58,000
78,000
75,500
Model
Number
A
Floor to
Vent
Conn.
in.
B
Jacket
Dia.
in.
RG1PV40S6N
RG1PV50S6N
★ RG2PV40S6N
★ RG2PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
57 5/16
58 1/4
57 5/16
58 1/4
66 7/8
66 7/8
66 1/8
64 3/16
69 7/16
20
22
22
24
20
22
22
22
26
Model
Number
A
Floor to
Vent
Conn.
mm.
B
Jacket
Dia.
mm.
RG1PV40S6N
RG1PV50S6N
★ RG2PV40S6N
★ RG2PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
1456
1480
1456
1480
1699
1699
1680
1630
1764
508
559
559
610
508
559
559
559
660
0.66
0.65
0.67
0.67
0.70
0.70
0.70
N/A
N/A
43
43
43
43
43
43
70
84
82
36
36
36
36
36
36
58
70
68
41
41
41
41
43
43
62
84
81
34
34
34
34
36
36
52
70
67
RG1PV40S6N
RG1PV50S6N
★ RG2PV40S6N
★ RG2PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
Liters
Nat.
kW
Input
LP
kW
Input
151
189
151
189
151
189
182
208
284
11.7
11.7
11.7
11.7
11.7
11.7
19.1
22.9
22.3
11.1
11.1
11.1
11.1
11.7
11.7
17.0
22.9
22.1
163
163
163
163
163
163
265
318
310
155
155
155
155
163
163
235
317
307
in.
N/A
N/A
N/A
N/A
N/A
N/A
13 1/2
13 3/8
13 3/8
N/A
N/A
N/A
N/A
N/A
N/A
50 1/8
47 15/16
511/2
140
166
142
168
146
173
187
219
260
J
Floor to
Water
Conn.
mm.
K
Depth
L
Floor to
Space Heating
Inlet
mm.
M
Floor to
Space Heating
Outlet
mm.
Approx.
Shipping
Weight
1245
1283
1245
1283
1473
1473
1467
1422
1543
629
679
679
730
629
679
679
679
781
2 or 3
2 or 3
2 or 3
2 or 3
2 or 3
2 or 3
3 or 4
3 or 4
3 or 4
40
40 5/8
40
40 5/8
50
50
50 1/8
47 15/16
51 1/2
11 3/4
11 3/4
11 3/4
11 3/4
113/4
113/4
11 3/4
111/2
13 1/2
47 1/2
48 1/4
47 1/2
48 1/4
56 3/4
56 3/4
56 3/8
54 5/8
59 1/2
8
8
8
8
8
8
11
8
11
49
50 1/2
49
50 1/2
58
58
57 3/4
56
60 3/4
C
Vent
Size
mm.
D
Floor to
T&P
Conn.
mm.
E
Floor to
Gas
Conn.
mm.
F
Floor to
Top of
Heater
mm.
H
C/L
of Water
Conn.
mm.
51or76
51or76
51or76
51or76
51or76
51or76
76 or 102
76 or 102
76 or 102
1016
1032
1016
1032
1270
1270
1273
1218
1308
298
298
298
298
298
298
298
279
343
1207
1226
1207
1226
1441
1441
1432
1388
1511
203
203
203
203
203
203
279
203
279
Max. Equivalent Length
Min. Equivalent Length
Number
1
of
2
90° Elbows
3
0.66
0.65
0.67
0.67
0.70
0.70
0.70
N/A
N/A
24 3/4
26 3/4
26 3/4
28 3/4
24 3/4
26 3/4
26 3/4
26 3/4
30 3/4
J
Floor to
Water
Conn.
in.
K
Depth
in.
H
C/L
of Water
Conn.
in.
†120 ft.
15 ft.
115 ft.
110 ft.
105 ft.
273
326
273
326
273
326
424
N/A
N/A
Approx.
Shipping
Weight
F
Floor to
Top of
Heater
in.
RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
1st Hour
Rating Energy
(Liters) Factor
M
Floor to
Space Heating
Outlet
in.
E
Floor to
Gas
Conn.
in.
3"
Vent Pipe
Recovery at
50°C Rise*
Nat.
LP
Liters/
Liters/
Hour
Hour
L
Floor to
Space Heating
Inlet
in.
D
Floor to
T&P
Conn.
in.
C
Vent
Size
Propane models feature a Titanium Stainless Steel propane burner. For Propane
(LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6”
to “10” (Not available on RG1PV55H6N). *Based on manufacturer’s rated recovery
efficiency. 120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes.
Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
H = ENERGY STAR® Qualified.
RG2PV40S6N RG1PV50S6N
2"
RG2PV50S6N RG2PV40T6N
RG1PV40S6N RG2PV50T6N Vent Pipe
†50 ft.
Max. Equivalent Length
Min. Equivalent Length
7 ft.
Number
1
45 ft.
of
2
40 ft.
90° Elbows
3
35 ft.
Capacity
Model
Number
mm.
N/A
N/A
N/A
N/A
N/A
N/A
343K
340
340
N/A
N/A
N/A
N/A
N/A
N/A
1273
1218
H
1308
lbs.
kg.
64
75
64
76
66
78
B 85
99
118
C
B
K
H
3"
Vent Pipe
†50 ft.
7 ft.
45 ft.
40 ft.
35 ft.
4"
Vent Pipe
†180 ft.
15 ft.
175 ft.
170 ft.
165 ft.
C
J
A
F
D&M
Subtract 5ft. for each additional 90° elbow
†For high altitude installations, consult the installation instructions.
General: All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working
J
pressure. All water connections are 3⁄4" NPT (19mm), all gas connections are 1⁄2" (13mm).
All models designcertified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and/or 10.3 and peak performance rated.
L
E
A
F
Dimensions and specifications subject to change without notice in accordance with our policy of continuousD&M
product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this
system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Ambler, PA
Sales 800-523-2931 l Fax 215-641-1670 / Technical Support 800-334-3393
E l Fax 269-795-1089 l LWarranty 800-531-2111 l Fax 269-795-1089
International: Telephone 215-641-9400 l Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 l Fax 905-238-0105 / www.bradfordwhite.com
1261-B-1216
©2016, Bradford White Corporation. All rights reserved.
Printed in U.S.A.