LECTUS fpadmin - Bosch Security Systems

LECTUS fpadmin - Bosch Security Systems
LECTUS FP admin SW
en
Installation manual
LECTUS FP admin SW
Table of Contents | en
3
Table of contents
1
System overview
4
1.1
Important Information
4
1.2
Important planning notes for contactless readers
5
2
Installation
6
2.1
Server and Client Installation
6
2.2
Start LECTUS_fpa Server Config
9
2.3
LECTUS FP admin 1.0
12
3
Configuration
14
3.1
Add a new Device
15
3.1.1
Check the operation mode
19
3.1.2
Reader Settings
20
3.2
LECTUS enrollment
21
3.2.1
Add a new user
21
3.2.2
Delete a Card
26
3.2.3
Data Transfer
27
3.3
Monitoring
29
3.4
Add Devices to the BIS System
30
3.5
Add Devices to the Access PE System
32
3.6
Add users to the BOSCH system via User ID
34
3.6.1
BIS-Access Engine
34
3.6.2
Access Professional Edition
36
3.7
Define Input Signals
38
3.7.1
Connecting Diagram
38
3.8
How to use the BOSCH code
39
3.8.1
Device Operation Mode
39
3.8.2
Wiegand Device
40
3.8.3
User Card
41
3.8.4
Transfer all users to Device
42
3.8.5
APE Wiegand Card Definition
43
3.8.6
APE Personnel Management
44
4
Bosch Migration Tool
45
Bosch Access Systems GmbH
2016-04 | 1.1 |
4
en | System overview
1
LECTUS FP admin SW
System overview
This instruction manual for authorized service providers
contains instructions on the installation and commissioning of
the Bosch fingerprint readers BioEntry Plus and BioLite Net..
The information in this instruction manual is, to the best of our
knowledge, valid at the time of publication.
As part of our commitment to customer service we nevertheless
welcome suggestions for improvements
1.1
Important Information
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
www.boschsecurity.com
© Bosch Sicherheitssysteme GmbH, 2016
Tel.: +49 (0)89 6290-0
Fax: +49 (0)89 6290 1020
Purpose of Equipment
This hardware comprises fingerprint readers for access control
and time attendance, which are suitable for mullion mount.
Country of Origin and Production Date
The label applied under the bottom of the reader housing gives
the essential information about country of origin and the
production date.
The Country of Origin is Korea.
The week and year of production can be read on the left side of
the label next to the word MANUFACTURED:. Read it according
to the code WW-YYYY, i.e. for example 32-2015 for week 32 in
2015.
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
1.2
System overview | en
5
Important planning notes for contactless
readers
Influences on reading distance
–
Metal in the "active" effective HF field.
–
Interference with other readers in immediate vicinity
(distance < 30 cm)
–
Interference with high-enery sources
–
Switch mode power supplies
–
Cable quality, shielding, and cross-section dimension
(remaining input voltage at reader, EMC)
Bosch Access Systems GmbH
2016-04 | 1.1 |
6
en | Installation
2
LECTUS FP admin SW
Installation
The LECTUS_fpadmin_Setup software is delivered on a CD with
the product.
This software is the LECTUS_fpadmin_ExpressSetup.exe.
2.1
Server and Client Installation
Notice!
If you update the first time from BioStar 1.6 or other versions to
LECTUS, uninstall the BioStar (Server, Client or Express) first
Stop the BioStar Server Service. Then uninstall the BioStar SW
(Server, Client or Express).
If you want to migrate readers of an existing system to be used
with LECTUS FP admin Software including all new
functionalities, use the migration tool as described in chapter 4
(Bosch Migration Tool).
Install the LECTUS server and client as follows:
–
Export LECTUS_fpadmin_ExpresSetup.exe from the CD to
the computer.
–
Click on the LECTUS_fpadmin_ExpressSetup.exe and run as
administrator.
If you encounter the following error message, ignore it.
–
Follow the installation guide.
After a successful installation these icons are displayed on your
desktop:
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
Installation | en
7
and
Notice!
For Windows 7 or higher you have to run the LECTUS fpadmin
SW as Administrator
Consequences
–
Right-click on the above icons and select Start as Admin, or
–
Set the option fix with a Right-Click on the icon.
–
Then select Properties > Advance and select Run as
administrator.
Set Run as Administrator for both icons:
Bosch Access Systems GmbH
2016-04 | 1.1 |
8
en | Installation
2016-04 | 1.1 |
LECTUS FP admin SW
Bosch Access Systems GmbH
LECTUS FP admin SW
2.2
Installation | en
9
Start LECTUS_fpa Server Config
Click the following icon to start the LECTUS_fpa Server:
On starting the LECTUS_fpa Server following message is
displayed:
Bosch Access Systems GmbH
2016-04 | 1.1 |
10
en | Installation
–
2016-04 | 1.1 |
LECTUS FP admin SW
Click OK to continue.
Bosch Access Systems GmbH
LECTUS FP admin SW
–
Installation | en
11
Click Start to continue.
Bosch Access Systems GmbH
2016-04 | 1.1 |
12
en | Installation
2.3
LECTUS FP admin SW
LECTUS FP admin 1.0
–
Click
–
Enter user ID and password and select Server Settings to
to start
continue:
–
Enter the Server IP address an Server Port No.:
–
Click the Test button. If the server is connected select Save
to close the window.
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
Installation | en
13
On first starting the system, define the administrator name
(AdminID) and Password in the window below:
–
Now login using the Admin ID and Password as defined
above:
Click Login to start the LECTUS fpadmin 1.0
Bosch Access Systems GmbH
2016-04 | 1.1 |
14
en | Configuration
3
LECTUS FP admin SW
Configuration
After the Suprema software has been installed, the following
features are described:
–
Device configuration
–
Adding a new user and its data
–
Defining a new device
–
Access Monitoring
Precondition
–
To be able to scan a reader check whether:
–
The fingerprint readers are connected with the
network,
–
Server and reader are in the same sub-network.
If the network settings of the reader are unknown, the user can
initialize a network reset (described in the reader manual).
The default network address after reset is 192.168.0.1.
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
3.1
Configuration | en
15
Add a new Device
Start the LECTUS_fpadmin V1.00 client.
Enter user name and password.
1.
Open the Device menu.
2.
Click the Add device task function.
Bosch Access Systems GmbH
2016-04 | 1.1 |
16
en | Configuration
2016-04 | 1.1 |
3.
Select the LAN option.
4.
Click the Next button.
5.
Activate the UDP control.
6.
Click the Next button.
LECTUS FP admin SW
Bosch Access Systems GmbH
LECTUS FP admin SW
7.
Configuration | en
17
Select the device to be added.
8.
Choose the Not Use option for DHCP.
9.
If necessary, fill in the fields IP address and Subnet.
10. Click the Modify button.
11. Finally click the Next button.
Bosch Access Systems GmbH
2016-04 | 1.1 |
18
en | Configuration
LECTUS FP admin SW
12. Select the found device
13. Click the Add button
14. Click the Finish button.
The new device is shown in the Device tree of the Server
Window.
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
3.1.1
Configuration | en
19
Check the operation mode
–
Check if the mode is on Card + Fingerprint
–
Set Card Reading Mode
–
Set format type to normal
–
Click Apply
–
Select the device
–
Set Get Host PC Time
–
Check if the Operation Mode Card + Fingerprint is set
to Always
–
Check if The Card ID Format Type is set to Normal
–
Click Apply.
Bosch Access Systems GmbH
2016-04 | 1.1 |
20
en | Configuration
3.1.2
LECTUS FP admin SW
Reader Settings
After adding the new device change the following settings:
2016-04 | 1.1 |
–
Open the Wiegand tab.
–
Set Wiegand Output to Wiegand (Card).
–
Click Apply.
Bosch Access Systems GmbH
LECTUS FP admin SW
3.2
3.2.1
Configuration | en
21
LECTUS enrollment
Add a new user
To add a new user follow the steps in the screenshots below:
1.
Open the User menu.
2.
Select the Add New User function from the Task menu in
the left frame.
Bosch Access Systems GmbH
2016-04 | 1.1 |
22
en | Configuration
LECTUS FP admin SW
3.
Enter the Name of the user.
4.
If a pin code is required enter a number of maximum six
digits in the Password field.
5.
2016-04 | 1.1 |
Additional user data can be added on the Details tab.
Bosch Access Systems GmbH
LECTUS FP admin SW
6.
Configuration | en
23
Open the Fingerprints tab and select a reader as
enrollment device.
7.
Click the Add button to add a fingerprint to the user.
8.
Place the index finger on the reader and click the Scan
button.
9.
Follow the instructions on the screen and, if the test is
positive, click the Apply button to confirm the changes.
Notice!
There is no warning for unsaved data.
If you leave the dialog without clicking the Apply button, all
data will be lost
Notice!
The selected enrollment reader will remain set for all
enrollment actions.
Bosch Access Systems GmbH
2016-04 | 1.1 |
24
en | Configuration
LECTUS FP admin SW
10. Open the Card tab and select the card type
11. Click the Card Management button.
–
2016-04 | 1.1 |
Select the Device ID of the enrollment reader.
Bosch Access Systems GmbH
LECTUS FP admin SW
Configuration | en
25
12. Click the Read Card Button and present a card to the
reader.
13. Click the OK button to close the dialog.
14. Click the Apply button to confirm the changes.
The new added card is displayed in the list control - see the red
frame.
Bosch Access Systems GmbH
2016-04 | 1.1 |
26
en | Configuration
3.2.2
LECTUS FP admin SW
Delete a Card
To delete a card proceed as follows:
1.
Select Card Type
2.
Click Management
3.
Check if Card ID is set to Zero
4.
Click OK to confirm
5.
Click Apply
The result can be found in the Card issue history.
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
3.2.3
Configuration | en
27
Data Transfer
To transfer the data to the fingerprint reader follow the steps
below:
1.
Select the Transfer All Users to Device function from the
Task menu
The following screen opens:
Bosch Access Systems GmbH
2016-04 | 1.1 |
28
en | Configuration
LECTUS FP admin SW
1.
Select the corresponded device.
2.
Activate the Overwrite users with different information
control.
2016-04 | 1.1 |
3.
Select the desired user.
4.
Click the Transfer to Device button.
Bosch Access Systems GmbH
LECTUS FP admin SW
3.3
Configuration | en
29
Monitoring
To check the configuration of the device have a look on the
events coming from the device.
1.
Open the Monitoring menu.
2.
Select the Realtime Monitoring tab.
Generate messages creating actions at the door.
1.
Verify that the done actions are shown on this page.
Bosch Access Systems GmbH
2016-04 | 1.1 |
30
en | Configuration
3.4
LECTUS FP admin SW
Add Devices to the BIS System
The using of the FPL readers in association with the
AccessEngine will be shown using a door model 1c.
Precondition
–
The AMC2 4W is successfully defined in the BIS
Configruation Browser and the connection is working fine.
–
The fingerprint reader is connected with the AMC over
Wiegand
Proceeding
The BIS software sets the reader address and the signals on the
corresponding places automatically. See the below attached
screen capture.
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
Bosch Access Systems GmbH
Configuration | en
31
2016-04 | 1.1 |
32
en | Configuration
3.5
LECTUS FP admin SW
Add Devices to the Access PE System
The using of the FPL readers in association with the Access
Professional Edition will be shown by using a door model 1c.
Precondition
–
The AMC2 4W is successfully defined and the connection is
–
The fingerprint reader is connected with the AMC over
working fine.
Wiegand.
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
Configuration | en
33
Proceeding:
1. Add a door model 1c.
2. Add a reader with the address 1.
3. Define the input signal Door sensor on connection place 1.
4. Define the output signal Door opener on connection place 1.
Bosch Access Systems GmbH
2016-04 | 1.1 |
34
en | Configuration
3.6
LECTUS FP admin SW
Add users to the BOSCH system via User
ID
The scope of this chapter is to show how the user Identification
Number (ID) of the Suprema data record is used in the Access
PE and in the BIS Access Engine as a card number.
Necessary settings in the LECTUS fpadmin
3.6.1
–
Select a device
–
Go to the Wiegand folder
–
Set Wiegand Output to Wiegand (user)
BIS-Access Engine
To assign the ID from the LECTUS_FP admin software, proceed
as follows:
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
1.
Configuration | en
35
Define a new person in the Access Engine dialog Persons or
select an existing one.
2.
Open the dialog Cards.
3.
Click the Record card button.
4.
In the Recording badge ID dialog enter the ID into the Card
5.
Click the OK button to confirm.
no. field. In this example the Suprema user ID is 5.
The Tester 22 has the ID 5 which has been assigned to the
samecard holder in the dialog manager of the BIS client.
Assign an authorization to the card holder and you will see
thathe will have an access granted.
This is also to be seen in the DMS and LAC consoles
Bosch Access Systems GmbH
2016-04 | 1.1 |
36
en | Configuration
3.6.2
LECTUS FP admin SW
Access Professional Edition
To assign the user ID from the Suprema software, proceed as
follows:
1.
Define a new person in the Access PE or select an existing
one.
2016-04 | 1.1 |
2.
Click the Assign card 1 button.
3.
Enter the User ID into the Card code field.
4.
Click the Assign card button to confirm the changes.
Bosch Access Systems GmbH
LECTUS FP admin SW
Configuration | en
37
Test the card
–
Present the card at the entry reader. The LogViewer will
show: not authorized
–
Assign the authorization to the card holder and he will get
access granted.
Bosch Access Systems GmbH
2016-04 | 1.1 |
38
en | Configuration
3.7
LECTUS FP admin SW
Define Input Signals
The following setting are required to control the LED of the
reader with the AMC. Define input signals for Access Denied (0)
and Access Granted (1):
3.7.1
2016-04 | 1.1 |
–
Select the device
–
Select Folder "Input"
–
if it is the first time click on Add
–
Input 0: Function, select: Access Denied Input
–
Input 1: Function, select: Access Granted Input
–
Click OK to continue.
Connecting Diagram
Bosch Access Systems GmbH
LECTUS FP admin SW
3.8
Configuration | en
39
How to use the BOSCH code
Use a Mifare Entry Plus or Bionet Lite reader as enrollment
device.
3.8.1
Device Operation Mode
1.
Select a reader device.
2.
Click the tab Operation Mode
3.
Set Operation Mode Card + Fingerprint to Always.
4.
Set Card Reading Mode to the Mifare basic setting Mifare
CSN only. The further settings for the Bosch Code are
described in chapter 3.8.3.
Bosch Access Systems GmbH
2016-04 | 1.1 |
40
en | Configuration
3.8.2
LECTUS FP admin SW
Wiegand Device
1.
Click the tab Wiegand
2.
Set Wiegand Output to Wiegand Card
A change of format is not necessary.
2016-04 | 1.1 |
Bosch Access Systems GmbH
LECTUS FP admin SW
3.8.3
Configuration | en
41
User Card
1.
Click the tab Card
2.
Set Card Type to Mifare Secure
3.
Press button Card Management
4.
Select Device Id
5.
Press button Read Card -> Card values are filled in
6.
Click Ok
7.
Click Apply
If the card ID is not unique the message “Same card exists”
appears.
Bosch Access Systems GmbH
2016-04 | 1.1 |
42
en | Configuration
3.8.4
2016-04 | 1.1 |
LECTUS FP admin SW
Transfer all users to Device
1.
Select Device
2.
Set flag Overwrite users with different information
3.
Click Transfer to Device
Bosch Access Systems GmbH
LECTUS FP admin SW
3.8.5
Configuration | en
43
APE Wiegand Card Definition
1.
Select APE Configurator > Wiegand Card Definition
2.
Set the 63 bit card type active.
Bosch Access Systems GmbH
2016-04 | 1.1 |
44
en | Configuration
3.8.6
2016-04 | 1.1 |
LECTUS FP admin SW
APE Personnel Management
1.
Select APE Personnel Management
2.
Assign the correct Bosch coded card
Bosch Access Systems GmbH
LECTUS FP admin SW
4
Bosch Migration Tool | en
45
Bosch Migration Tool
Migration
Go to folder C:\Program Files (x86)\LECTUS_fpa\Server\ and
start the application RemodelBoschDevice_v1.0.exe.
1.
Click Search to search for a connected device.
2.
Select a device to migrate
3.
Click Write to write the Bosch ID into the device.
4.
Click FwFile to select a firmware file to upgrade
Make sure to select the proper upgrade file.
5.
Click FwUpdate to upgrafe the selected device.
A “success” pop-up window appears if the firmware has
been successfully upgraded.
Bosch Access Systems GmbH
2016-04 | 1.1 |
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
www.boschsecurity.com
© Bosch Sicherheitssysteme GmbH,
2016
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising