Fiber Optic Outside Plant Cables (4

Fiber Optic Outside Plant Cables (4
Fiber Optic Outside Plant Cables (4 - 144 Fibers)
4- to 12-Fiber,
Armored
Strength Members
Armor
Water Blocking
Tapes
Armor
Water Blocking
Strength Members
Jacket
Jacket
Filled Buffer
Tubes With
Fibers
Filler
Fibers
Central
Strength
Member
Filled Buffer Tube
24- to 144-Fiber,
Armored
4- to 12-Fiber,
Dielectric
Filler
24- to 144-Fiber,
Dielectric
Description:
AMP NETCONNECT outdoor cables are designed for campus-type environments or for long runs between buildings in aerial, duct or direct buried
installations.
Standards Compliance:
AMP NETCONNECT cables are designed and tested to conform to the fiber and cable performance requirements of the TIA 568, ISO 11801, and
ICEA-640 Standards. Accordingly, the cables meet or exceed all of the performance requirements for current and proposed applications such as
IEEE 802.3 Ethernet (including 10 Gigabit Ethernet), ATM, Fibre Channel, FDDI and others. The cables are available in armored single tube,
dielectric stranded tube and armored stranded tube constructions and with singlemode, 50/125µm, XG (850nm laser-optimized 50/125µm) or
62.5/125µm fiber.
Specification (Text in brackets […] requires a choice):
The optical fiber cable shall consist of [four, six, eight, twelve, twenty-four, thirty-six, forty-eight, seventy-two, ninety-six or 144]
[singlemode, 50/125µm, 850nm laser-optimized 50/125µm, 62.5/125µm] strain-free fibers. [Four, Six, Eight or Twelve] colored fibers shall be
encased in a colored buffer tube filled with a water-barrier filling compound. Single tube constructions shall have a single buffer tube, waterblocking strength members, corrugated steel tape armor and a medium-density polyethylene (MDPE) outer jacket. Dielectric stranded tube
constructions shall have multiple buffer tubes and fillers (if necessary), water-blocking tapes and/or yarns, strength members and a medium-density
polyethylene (MDPE) outer jacket. Armored stranded tube constructions shall have multiple buffer tubes and fillers (if necessary), water-blocking
tapes and/or yarns, strength members, corrugated steel tape armor and a medium-density polyethylene (MDPE) outer jacket. The nominal cable
dimensions shall be [insert table or values from the Mechanical Specifications table below]. The cable jacket shall be black. The cable shall
comply with the performance requirements listed in the Performance Characteristics table [insert table or values from the Performance
Characteristics table]. The cable shall be AMP NETCONNECT part number [insert tables or part numbers from the Part Numbers tables
below]. The temperature ratings for storage, shipping, installation and operation shall comply with the Temperature Ratings table [include
Temperature Ratings table below]. Hybrid cables shall be constructed in order of core size from smallest to largest. (i.e. single-mode fibers
taking the first positions, followed by 50/125µm then 62.5/125µm).
Cable Print:
Cables will be marked with “AMP NETCONNECT F O CABLE [cable description] [fiber count]X[fiber type] [yy/ww] [xxxxx]" or “AMP
NETCONNECT XG F O CABLE [cable description] [fiber count]X[fiber type] [yy/ww] [xxxxx]”, where cable description defines the cable design
[OSP for dielectric, OSPA for armored] fiber count defines total number of fibers in the cable, fiber type defines the fiber type [9/125 for singlemode, 62.5/125, 50/125, 850nm LOF 50/125 for XG], yy is year of manufacture, ww is week of manufacture (calendar week) and xxxxx is length
marking in feet.
Shipping and Packaging:
The cable will be shipped on a wooden reel. The cable length billing and shipping tolerances are -0%/+10%.
Materials:
Optical fibers are silica glass surrounded by acrylate coating. The filling compound is a hygroscopic gel. The buffer tubes are thermoplastic and
the central members are glass-reinforced plastic (GRP). The strength members are aramid and/or fiberglass yarns. Water blocking materials are
impregnated with super absorbent polymers. Cable jacket is black polyethylene. Armor is plastic-coated steel tape.
Fiber Optic Outside Plant Cables (4 - 144 Fibers)
Part Numbers:
OSP Dielectric Single Loose Tube Cable (4 to 12 Fibers, Single Tube)
Description
XG Fiber
50/125µm Multimode
62.5/125µm Multimode
Singlemode
Part Number
4-Fiber
6-Fiber
8-Fiber
12-Fiber
8-1664212-5
2-1664212-5
1-1664213-5
0-1664211-5
8-1664215-5
2-1664215-5
1-1664216-5
0-1664214-5
8-1664218-5
2-1664218-5
1-1664219-5
0-1664217-5
8-1664221-5
2-1664221-5
1-1664222-5
0-1664220-5
OSP Dielectric Stranded Loose Tube Cable (48 to 144 Fibers, 12 Fibers Per Tube)
Description
XG Fiber
50/125µm Multimode
62.5/125µm Multimode
Singlemode
24-Fiber
8-1664191-5
2-1664191-5
1-1664192-5
0-1664190-5
36-Fiber
8-1664194-5
2-1664194-5
1-1664195-5
0-1664193-5
Part Number
48-Fiber
72-Fiber
8-1664197-5
8-1664200-5
2-1664197-5
2-1664200-5
1-1664198-5
1-1664201-5
0-1664196-5
0-1664199-5
96-Fiber
8-1664203-5
2-1664203-5
1-1664204-5
0-1664202-5
144-Fiber
8-1664206-5
2-1664206-5
1-1664207-5
0-1664205-5
OSP Armored Single Loose Tube Cable (4 to 12 Fibers, Single Tube)
Description
XG Fiber
50/125µm Multimode
62.5/125µm Multimode
Singlemode
Part Number
4-Fiber
6-Fiber
8-Fiber
12-Fiber
8-1664161-5
2-1664161-5
1-1664162-5
0-1664160-5
8-1664164-5
2-1664164-5
1-1664165-5
0-1664163-5
8-1664167-5
2-1664167-5
1-1664168-5
0-1664166-5
8-1664170-5
2-1664170-5
1-1664171-5
0-1664169-5
OSP Armored Stranded Loose Tube Cable (24 to 144 Fibers, 12 Fibers per Tube)
Description
XG Fiber
50/125µm Multimode
62.5/125µm Multimode
Singlemode
Part Number
24-fiber
36-Fiber
48-fiber
72-Fiber
96-fiber
144-Fiber
8-1664173-5
2-1664173-5
1-1664174-5
0-1664172-5
8-1664176-5
2-1664176-5
1-1664177-5
0-1664175-5
8-1664179-5
2-1664179-5
1-1664180-5
0-1664178-5
8-1664182-5
2-1664182-5
1-1664183-5
0-1664181-5
8-1664185-5
2-1664185-5
1-1664186-5
0-1664184-5
8-1664188-5
2-1664188-5
1-1664189-5
0-1664187-5
Hybrid (Single-mode and 62.5/125µm Multimode Fiber) Dielectric Outdoor Cables
Description
# of Singlemode
Fibers
# of 62.5/125µm
Fibers
Part Number
24-Fiber Hybrid
12
12
4-1664208-5
36-Fiber Hybrid
12
24
4-1664209-5
72-Fiber Hybrid
24
48
4-1664210-5
Note: Hybrid cables shall be constructed in order of core size from smallest to largest. (i.e. single-mode fibers taking the first
positions, followed by 50/125µm then 62.5/125µm).
Fiber Optic Outside Plant Cables (4 - 144 Fibers)
Performance Specifications:
AMP NETCONNECT outside plant cables are designed and tested in accordance with TIA 568, ISO 11801, ICEA 640, Telcordia
(Bellcore) and GR-20-CORE. Performance specifications are measured in accordance with the Fiber Optic Test Procedures (EIA/TIA-455
documents) and the test procedures of IEC 60793 and IEC 60794.
Mechanical Specifications
Nominal O.D.
mm (in)
Nominal Weight
kg/km (lbs/1000ft)
Armored
4-Fiber
6-Fiber
8-Fiber
12-Fiber
24-Fiber
36-Fiber
48-Fiber
72-Fiber
96-Fiber
144-Fiber
10.7 (0.42)
10.7 (0.42)
10.7 (0.42)
10.7 (0.42)
13.4 (0.53)
13.4 (0.53)
13.4 (0.53)
14.2 (0.56)
16 (0.63)
20 (0.78)
Dielectric
4-Fiber
6-Fiber
8-Fiber
12-Fiber
24-Fiber
36-Fiber
48-Fiber
72-Fiber
96-Fiber
144-Fiber
6.0 (0.24)
6.0 (0.24)
6.0 (0.24)
6.0 (0.24)
11.6 (0.46)
11.6 (0.46)
11.6 (0.46)
12.6 (0.5)
14.4 (0.57)
18 (0.7)
Cable Type
Fiber Count
Rated Tensile Load
Minimum Bend Radius
Install
N (lbf)
Long Term
N (lbf)
Install
mm (in)
Long Term
mm (in)
120 (78)
120 (78)
120 (78)
120 (78)
170 (120)
160 (110)
160 (110)
200 (140)
230 (160)
350 (240)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
214 (8.4)
214 (8.4)
214 (8.4)
214 (8.4)
268 (10.6)
268 (10.6)
268 (10.6)
284 (11.2)
320 (12.6)
392 (15.4)
107 (4.2)
107 (4.2)
107 (4.2)
107 (4.2)
134 (5.3)
134 (5.3)
134 (5.3)
142 (5.6)
160 (6.3)
196 (7.7)
32 (22)
32 (22)
32 (22)
32 (22)
100 (68)
93 (63)
93 (63)
130 (88)
160 (110)
250 (170)
1000 (220)
1000 (220)
1000 (220)
1000 (220)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
2700 (600)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
890 (200)
100 (3.9)
100 (3.9)
100 (3.9)
100 (3.9)
232 (9.2)
232 (9.2)
232 (9.2)
252 (10.0)
288 (11.4)
360 (14.2)
60 (2.4)
60 (2.4)
60 (2.4)
60 (2.4)
116 (4.6)
116 (4.6)
116 (4.6)
126 (5.0)
144 (5.7)
180 (7.1)
Performance Characteristics
XG Fiber
(850nm/1300nm)
Multimode 50/125 m
(850nm/1300nm)
Multimode 62.5/125 m
(850nm/1300nm)
Single-mode
(1310nm/1550nm)
3.5/1.5 dB/km
1500/500 MHz km
3.5/1.5 dB/km
500/500 MHz km
3.5/1.0 dB/km
200/500 MHz km
Not Applicable
850nm Laser Bandwidth
2000 MHz km
Not Applicable
Not Applicable
Not Applicable
1000BASE-SX Distance
1000BASE-LX Distance
10GBASE-SR Distance
10GBASE-LX4 Distance
2-900m
2-550m
2-300m
2-300m
2-600m
2-600m
2-82m
2-300m
2-300m
2-550m
2-33m
2-300m
2-5000m
2-5000m
NST
2-10000m
Maximum Attenuation
OFL Bandwidth
Temperature Ratings
Operation
-40°C to +70°C
(-40°F to +160°F)
Installation
-20°C to +60°C
(-22°F to +140°F)
Storage/Shipping
-40°C to +70°C
(-40°F to +160°F)
Specifications subject to change without notice. All stated mechanical specifications are
considered nominal and are subject to normal manufacturing tolerances.
In the U.S.A
1-800-553-0938
Canada
905-475-6222
Mexico
525-729-0400
South and Central Americas
54-11-4733-2200
web: http://www.ampnetconnect.com/
e-mail: networking.help@tycoelectronis.com
Revision G – 8/18/2005
© Copyright 2005 Tyco Electronics Corporation. All rights reserved.
AMP, NETCONNECT, AMP NETCONNECT, Tyco and Tyco Electronics are trademarks.
0.5/0.5dB/km