Fuji PHL Paperless Recorder ECNO1013

Fuji PHL Paperless Recorder ECNO1013
Type: PHL
Long Term Record Data Saving
1.5years in Compact Flash
(In case of using 256MB Compact Flash)
Saved Data playback
Saved data in Memorry card can be easily called out and played
back on display
Math and totalization
These functions are available as standard.
Communication
RS485, MODBUS RTU protocol is available.
Screen saver
Period of non-operation exceeds the setting value of parameter,
recorder turns off the backlight of LCD.
PC support softwares (Data Viewer/Parameter Loader)
Supplied in a CD-ROM as a part of standard accessory
Compact size
160 (W) X 144 (H) X 185 (D) mm (Panel mount)1.5 kg compact size
9-point recording and 18-point max. recording
12 types of thermocouples, 5 types of resistance bulbs and voltage/current input are available
ECNO:1013
Provides, flexibility and variety in the handing of record data.
Status Display
Allows you to display screen name, calendar, alarm information, recording status, writing status of measured data in
Compact Flash, and fitting status of the card into the
recorder slot.
Time display
Indicates the time and time scale of recorded data.
Trend Display
Allows you to view measured result in waveforms.
Digital Display
Allows you to view measured values in a digital form.
Key panel
Allows you to perform the recording start/stop, selection of
display, setting, data display/change.
Power indicator
During power on, LED turns on.
While screen saver is working, it flickers.
orth
s' w rded
r
a
e
.5 y be reco
ut 1
Abo ata can Flash
of d ompact
in C 6 MB).
(25
Mathematics function (programming formula) as standard
You can program formula using below operand.
Addition, Subtraction, Multiplication, Division Absolute value, X to the power of Y, Logarithm, Natural
logarithm, Exponential function, Humidity, Average value, Maximum value, Minimum value.
Communication
RS485, MODBUS RTU protocol is available. Communication rate is 9600 or 19200 bps and multi-drop/up
to 32 recorders connectable including master station. Total extension is 500m or less.
Calculation function offered as standard
Subtraction
Difference between the values of each channel can be calculated.
F value calculation
Extinction rate of bacteria by heat sterilization can be calculated per channel according to the measured
temperature.
Totalization
Measured value of each channel can be totalized.
Reference time can be selected from day, hour, minute and second.
Square root extraction
Square root extraction of the input value of each channel can be performed.
2
Wide variety of display mode
Trend recording (horizontal)
Trend recording (vertical)
Measured result is horizontally displayed in real time.
Measured result is vertically displayed in real time.
Bar graph
Analog meter
Measured values are displayed in bar graph.
Measured values are displayed in analog meters.
Digital display
Totalized data display
Channel No., Tag No. engineering unit, and alarm
information are displayed in digital form, in addition to
measured values.
Totalized data of each channel is digitally displayed.
(If power failure occurs while in totalizing operation and the
power is restored later, the data being totalized is cleared.)
Historical trend display
Event summary display
Past data saved to Compact Flash can be viewed.
Scroll function is usable.
Alarm status and external control input status for each
channel are displayed.
3
Specifications
General specifications
Storage capacity
•About 1.5 years at display refresh cycle of 30 seconds
Mounting method
Panel flush mounted
(ASCII)
Material
Molding resin (case, bezel)
•About 6 years (Binary)
External dimensions
<Panel mount>
and mass
160 x 144 x 185 mm, about 1.5 kg (9-point input)
Power supply voltage
100V to 240V AC, 50/60 Hz
Power consumption
About 42VA (at 200VAC)
External terminals
Screw terminals (M3 thread)
Input unit
(9-channel recording, 256MB compact flash used)
Amount of memory used The display unit displays how much the memory card
has been used via bar graphs. The recording will stop
if the amount of recorded data exceeds the capacity.
Alarm function
No. of settings
Up to 4 alarms are settable for each channel.
No. of inputs
9 or 18 points
Type of alarm
High/Low limits
Measuring cycles
100ms/9, 18 points
Indication
Alarm status is displayed on digital display unit when
Input signal
Thermocouple: 12 types
an alarm occurs. Histories are displayed in the alarm
summary.
(B, R, S, K, E, J, T, N, W, L, U, PN)
Resistance bulb: 5 types
Output
DC voltage:
Reference performance
(0 to 50mV, 0 to 500mV, 0 to 5V or 1 to 5V)
Indication accuracy
±(0.15%+1 digit) of input range
Accuracy of the next range is ±(0.3%+1 digit).
DC current:
Input types
10 points as relay output (option)
18 points as open-collector transister output (option)
(Pt100, JPt100, Ni100, Pt50, Cu50)
(connecting optional shunt resistor to input terminal)
Thermocouple B: 400°C to 600°C, thermocouples R
Selected from the key panel
and S: 0°C to 300°C, thermocouples K, E, J, T, L,
(the same type should be set for every 2 channels)
and U: -200°C to -100°C
Burn-out function
Equipped with thermocouple and resistance bulb inputs Indication resolution
Reference junction
as standard.
0.1°C
Calculation function
Primary delay filter, scaling, calculation of difference
Compensation accuracy Thermocouples R, S, B and W: ±1.0°C
between channels, F value calculation, totalization,
Input resistance
and square root extraction
Others
±0.5°C
About 1M
Mathematics function
Clock
With calendar function
Formula
Memory backup
Parameter settings are saved to the internal non-
It can be set 1 main formula and 3 temporary one.
Addition, Subtraction, Multiplication, Division
volatile memory. The clock is backed up by a built-in
Absolute value, X to the power of Y, Logarithm,
lithium battery. Trend data is back up only 400
samplings.
Natural logarithm, Exponential function, Humidity,
Average value, Maximum value, Minimum value.
Input signal
Memory full alarm
alarm output.
(ch1 to ch30), Constant (No.1 to No.20),
When the battery for backup of clock and SRAM
Communication input (No.1 to No.12)
Low battery alarm
5.7" TFT color LCD (320 X 240 dots) (The LCD may
Optional specifications
have some pixels that do not stay on or off.
Alarm (relay) output/DI
10 relay outputs and 5 DI are added.
Due to the characteristics of liquid crystal, the
(Cannot be mounted
Alarm output: SPST Output for each channel or
brightness may not be uniform, which is not a failure.)
to 18-point input type.)
common channel is possible.
Display unit
Display
When the amount of recorded data exceeds the
capacity of memory card, recorder can energize the
DI (DI1 to DI10), Totalize (ch1 to ch30), Analog input
becomes low, recorder can energize the alarm output.
Life of backlight
50,000 hours
DI input: 5 no-voltage contact input points, Recording
Display contents
•Trend display
start/stop, message setting, F value caliculation
(in vertical and horizontal direction) selected in the
resetting, Totalizing start/stop, Totalizing reset or LCD
turning on functions can be performed.
refreshment cycles of 1 sec to 12 hours.
Scale display/non-display selectable
Alarm (open-collector)
18 open-collector outputs and 5 DI are added as option.
•Bar graph or analog meter display
output/DI
Alarm output: Open-collector transister output for each
(refresh cycle: 1 second)
channel or common channel is possible.
•Digital display (in refreshment cycle of 1 sec)
DI input: 5 no-voltage contact input points, Recording
•Event summary display
start/stop, message setting, F value caliculation
(alarm and message summary)
resetting, Totalizing start/stop, Totalizing reset or LCD
turning on functions can be performed.
•Historical trend display (Compact Flash memory data.)
•Totalized data display
Communication
Bourate/parity: 9600, 19200bps/none, odd or even
•Group setting (4 groups at the maximum)
(RS485, MODBUS)
Length/Unit: 500m (total) /32units max (include master)
Compact Flash card (Format as FAT16 or FAT, or
PC support software (standard-supplied CD-ROM)
Recording function
Recording medium
Recommanded converter: K3SC-10/Omron Corp.
recorder can’t read and write.)
O/S
Windows 98/XP/2000
Memory capacity
256MB, max.
PC/AT-compatible
Operation on PC98-series machines by NEC is not
Recording method
Writing starts in fixed cycles by turning ON the REC
machine
guaranteed.
Operation on self-made or shop-brand PCs is not
key on the front panel.
guaranteed.
Data is recorded in a new file every time the
recording starts.
Required memory capacity 64 MB or more
Data save cycles
Links to refreshment cycle of the trend display
Contents
Data format
•ASCII About 166 bytes per sampling
Trend data
The following types are included as standard.
1) Data viewer software
(at 9 channel inputs)
It allows you to view the past trend recorded data
•Binary (Data cannot be read directly into Excel, etc.)
from the data saved to the Compact Flash on PC.
About 40 bytes per 1 sampling (9-channel input)
Historical trend and event display functions are
Maximum value and minimum value are saved from
the data that are sampled in measuring cycles.
provided.
2) Parameter loader software
Event data
Alarm data and message data are saved.
It allows you to perform setting/change of various
Totalized data
Stores data totalized during specified period of time.
parameters on PC.
4
A convenient PC support software package is included as standard
Past data saved to Compact Flash can be
viewed on personal computer.
Parameters for the recorder can be easily set
and changed from personal computer.
Historical trend data screen
Before use, install PC support software supplied as standard.
• O/S: Windows 98/XP/2000
• Required storage capacity: 64 MB
• Provide PC card adapter separately.
Recomended type: SDCF-31-03 (SanDisk Co.)
PC/AT-compatible machine
• Operation on PC98-series machines by NEC is not guaranteed.
• Operation on self-made or shop-brand PCs is not guaranteed.
Parameter setting screen
Before use, install PC support software supplied as standard.
• O/S: Windows 98/XP/2000
• Required capacity of memory: 64 MB
• A communication cable between recorder and pc is optional.
Type: PHZP0201
PC/AT-compatible machine
• Operation on PC98-series machines by NEC is not guaranteed.
• Operation on self-made or shop-brand PCs is not guaranteed.
Scope of supply
Code Symbols
Quantity
Panel mount
Item
Main unit
1
Panel mounting bracket
1
CD-ROM PC software
1
PHL
Digit
Specifications
4 <Number of input points>
9
Instruction manual
Compact flash (16MB)
1
Watertight panel packing for the front panel
1
18
11
4 5 6 7 8 9 10 11 12 13
1 B 1 1 - E 1
V
Note
1
Note 1 2
<Alarm (relay) output/DI input>
Noise filter for power cable
1
Without
0
AC power cord (2m)
–
With
1
12
Option
Item
Type
Specifications
Shunt resistor for DC current input
PC loader communication cable
PHZP0101
PHZP0201
PHZP0601
10±0.1%
With connector, Length: 3m
CD-ROM with instruction
manuals and softwares
Terminating resister (100ohm)
D-sublight 25pins connector
with male terminal
Transmission cable (PHL to PC)
Transmission cable (PHL to PHL)
For compact flash
256MB
192MB
128MB
96MB
64MB
32MB
PHZP0701
PHZP0801
PC card adapter (SanDisk)
Compact flash (SanDisk)
PHZP0901
PHZP1001
SDCF-31-03
SDCFB-256-801
SDCFB-192-801
SDCFB-128-801
SDCFB-96-801
SDCFB-64-801
SDCFB-32-801
<Communication, Alarm (open-collector)
output/DI input>
Without
Y
With
R
Note 1: Cannot be selected if 1 is selected for the 11th digit.
Note 2: Input signals are classified into the following 4 groups. Make the
setting so that the consecutive 2 channels (1ch and 2ch for example) are
assigned the input signal categorized in the same group.
Group 1: Thermocouple (12 kinds), 50mV
Group 2: Pt100. JPt100, Ni100, Cu50, Pt50
Group 3: 500mV
Group 4: 1-5V, 0-5V
Input signals can be arbitrarily selected for channels 9 and 18.
Note 3: Windows and Excel are registered trademarks of Microsoft
Corporation.
Note 4: SanDisk compact flash is a trademark of SanDisk.
Note 5: PC98 series are registered trademarks of NEC Corp.
Note 6: MODBUS R is the registered trademark of Gould Modicon.
5
Outline Diagram and Panel Cut (Unit: mm)
Panel mount type
9 input points
Digital input & alarm output (Option)
Panel
2T26
T
Mounting brackets
Input terminal
DIOSHLD A6 DO11 COM 24VDC
IN
DIO-ON
TRX1 TRX2
R-MODULE
Rcj
Fuji Electric
144
136.5
161
N
100 240VAC
Source
terminal
L
160
140
136.5
185
21.6
Communication, digital input and
alarm output terminal.
24.6 when watertight packing is mounted.
In the case of 9-point input
Note: When another instrument or a floor surface is under the bottom of this unit, allow a space of 100mm or larger between them and the bottom of this unit.
18 input points
Input terminal (ch10 to ch18)
Mounting brackets
Panel 2T26
T
Input terminal (ch1 to ch9)
DIOSHLD A6 DO11 COM 24VDC
IN
TRX1 TRX2
R-MODULE
Rcj
Fuji Electric
DIO-ON
R-MODULE
Rcj
Fuji Electric
144
136.5
161
N
100 240VAC
Source
terminal
L
140
160
21.6
136.5
185
24.6 when watertight packing is mounted.
Communication, digital input
and alarm output terminal.
In the case of 18-point input
Note: When another instrument or a floor surface is under the bottom of this unit, allow a space of 100mm or larger between them and the bottom of this unit.
Panel cutout
For mounting
one unit
For mounting
multiple unit
(160Xn–22) +20
6
137 +1.5
0
137 +1.5
0
137 +1.5
0
External connection diagram
9-point input
Input terminal
Thermo- Resistance
Voltage couple
bulb
231
211 DI1
232
212 DI2
233
213 DI3
234
214 DI4
235
215 DI5
236
216 DO1
237
217 DO2
+
CH6
CH7
–
+
–
–
+
CH8
221 DO6
241
63
71
72
–
+
–
82
222 DO7
242
83
223 DO8
243
+
224 DO9
244
CH9
–
+
91
–
92
225 DO10
245
11
12
13
21
22
23
31
33
81
93
Power terminal
Resistance ThermoVoltage
bulb
couple
32
RCJ
220 DO5
240
62
73
219 DO4
239
61
–
+
218 DO3
238
+
Communication, digital input
and alarm output terminal.
41
42
43
51
52
+
+
–
–
+
+
–
–
+
+
–
–
+
+
–
–
+
+
–
–
CH1
CH2
CH3
CH4
CH5
PCD
53
1
14
13
25
6
7
8
9
10
11
12
15
16
17
18
19
20
21
22
23
24
2
3
4
5
AC100 to 240V
50/60Hz
VPD
PCD
VPD
DO12
DO13
DO14
DO15
DO16
DO17
DO18
DO19
DO20
DO21
DO22
DO23
DO24
DO25
DO26
DO27
DO28
DI7
DI8
DI9
DI10
VPD
24VDCIN
DIO-COM
PCD
DO11
DI6
PCD
SHLD
TRX2
–
TRX1
+
(shield)
(–)
(+)
24Vdc
MODBUS
communication
Alarm output/
DI input terminal
PCD
18-point input
Input terminal
+
CH15
CH16
Thermo- Resistance
couple
bulb
+
–
–
+
+
–
–
161
162
163
171
172
173
CH17
CH18
+
–
–
+
+
–
–
112
121
122
123
131
133
181
182
183
191
192
193
+
+
–
–
Voltage
CH10
+
CH6
Thermo- Resistance
couple
bulb
+
–
–
+
+
–
–
113
132
RCJ
+
Resistance ThermoVoltage
bulb
couple
111
141
142
143
151
152
153
+
+
–
–
+
+
–
–
CH11
CH7
61
62
63
71
72
73
CH12
+
–
+
–
+
+
–
–
CH13
+
CH8
+
–
–
+
+
CH9
–
–
12
13
21
22
23
31
33
81
82
83
CH14
Resistance ThermoVoltage
bulb
couple
11
32
RCJ
91
92
93
Power terminal
41
42
43
51
52
53
+
+
–
–
+
+
–
–
+
+
–
–
+
CH1
CH2
CH3
+
–
–
+
+
–
–
CH4
CH5
PCD
1
14
13
25
6
7
8
9
10
11
12
15
16
17
18
19
20
21
22
23
24
2
3
4
5
AC100 to 240V
50/60Hz
VPD
PCD
DO12
DO13
DO14
DO15
DO16
DO17
DO18
DO19
DO20
DO21
DO22
DO23
DO24
DO25
DO26
DO27
DO28
DI7
DI8
DI9
DI10
VPD
VPD
24VDCIN
PCD
DIO-COM
DO11
PCD
DI6
SHLD
TRX2
–
TRX1
+
(shield)
(–)
(+)
24Vdc
MODBUS
communication
Voltage
Communication, digital input
and alarm output terminal.
PCD
Note: In the case of current input, connect the optional
shunt resistor to the voltage input terminal.
7
Fuji Electric
Your distributor:
Coulton Instrumentation Ltd
17 Somerford Business Park, Christchurch, BH23 3RU, UK
Tel: +44 1202 480 303
E-mail: sales@coulton.com
Web: www.coulton.com
Information in this catalog is subject to change without notice.
Printed in Japan 2004-5/30FIS
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising