DTS DC - ProtoConvert
™
DTS DC
DC Energy Sub-meter with Remote Communications
FEATURES
• DC power / energy sub-meter provides Voltage, Current, Power
and Energy measurements
• Bi-directional for renewable systems (NET metering)
• Interfaces with shunt or external Hall Effect current sensors
• Up to 800Vdc Voltage input
• Embedded Ethernet connectivity - Modbus/TCP, BACNet/IP,
SNMP or DNP 3.00
• RS-485 connectivity - Modbus RTU or BACnet MS/TP
• Communications setting via DIP switches for Modbus RTU
• LonWorks FT-10 communications
• 2 digital status/counter inputs OR digital outputs - optional
• Compact DIN rail design
• User configurable using DTS Config software
• User-definable Modbus register area
• SunSpec Alliance certified
• Designed and Manufactured in the USA. Complies with the
Buy American Provisions of ARRA Section 1605
RLOGI
SU
C
M
A
DE
A
INC
MEA
asy
and E
e
l
i
t
Versa onfigure!
to C
IN U
S
A
S
MA
Available
D E embedded
with
IN U
Ethernet
APPLICATIONS
*
Wind
generators
Solar / PV
INPUTS
Battery chargers
and systems
DC
DC INPUT
MEASUREMENT PARAMETERS*
COMMS & I/O
REMOTE
DIGITAL I/O
IN/OUT IN/OUT
TCP
Digital Digital Digital
In/Out 1 In/Out 2 Output
DIGITAL I/O
REMOTE
BAUD / ADDRESS
OFF
8-way DIP
Switch
RS-485 or FT-10
IN/OUT IN/OUT
ON
Digital Digital Digital
In/Out 1 In/Out 2 Output
Data centers
MEASUREMENT PARAMETERS *
Measurements
DC Volts (Instantaneous, Max and Min)
DC Current (Instantaneous, Max and Min)
Power
DC Power - kW (consumed/generated)
Bi-directional for renewable systems
Energy
DC Energy - kWh (consumed/generated)
Setpoints, Alarms, Control
Pulse / Status Outputs
Counter / Status Inputs
Communications
Modbus RTU
Modbus TCP
BACnet MS/TP
BACnet / IP
SNMP
DNP 3.00 over IP
LonWorks FT-10
DTS DC
✓
✓
✓
✓
✓
1–3
2
✓
✓
✓
✓
✓
✓
✓
* Model dependent
Call Toll Free: 1-877-PQ-SOLNS (1-877-777-6567) or 303-805-5252 email: info@measurlogic.com
Burden:
Isolation:
Operating temp:
Storage temp:
Humidity:
SPECIFICATIONS*
Mechanical:
Connection:
Measuring Circuits:
Voltage range:
0 - 50, 150, 400 or 800Vdc
Permanent overload:
1.2 x (1.05x for 800Vdc range)
Self powered:
120-400 Vdc, 420 Vdc Max
Input Impedance:
1MΩ for 400Vdc range & 2MΩ for
800Vdc range
Current Input Options: 0 - 5A (direct input)
>5A (external current shunt or Hall
effect sensor)
Permanent overload:
1.25 x In
Shunt:
50 - 100mV (configurable)
Hall Effect sensors:
0-4Vdc or 0-5Vdc
0-20mA or 4-20mA
Accuracy:
Voltage:
0.5% (10-110%)
Current:
0.5% (10-120%)
Power:
0.5% (10-120%)
Energy:
0.5% (10-120%)
Weight:
DTS DC -
Weight:
1lb (0.45 kg)
ab
Communication: (Serial)
Connection:
3 way pluggable, screw terminal
Protocols:
Modbus RTU or BACnet MS/TP
Communications: (LonWorks)
Current
& Voltage
Inputs
Connection:
2 way
pluggable, screw terminal
Protocols:
LonWorks FT-10
1lb (0.45 kg)
Communication: (Serial)
Connection:
3 way pluggable, screw terminal
Protocols:
Modbus RTU or BACnet MS/TP
Counter / Status
Type:
Min Pulse Width:
Max Current/Voltage:
Connection:
Communications: (LonWorks)
Connection:
2 way pluggable, screw terminal
Protocols:
LonWorks FT-10
Pulse / Status Outputs: - Optional
Type:
Potential Free, N.O. Solid State Relay
Pulse Width:
100 mS default
Min 50 mS, User configurable up to 10 Seconds
Max 10 Pulses per Second
Pulse Rate:
1 Pulse / 1 kWh default, User configurable
Max On-Resistance:
30 ohm
Max switching voltage: 240Vac
Max switching current: 120mA (350mA for 10mS)
Connection:
Isolated Pin-Pair (Output 3, Outputs 1 and/or 2)
-
cd
Counter / Status
Type:
Min Pulse Width:
Max Current/Voltage:
Connection:
-
e
Inputs: - Optional
Dry Contact
50mS, Max 10 Pulses per Second
15mA / 6V
2 Pin-Pairs (Inputs 1 and/or 2)
-
Standards & Safety:
ETL listing:
Pending
Communications
I/O
Options**
Designed to:
UL Std
61010.1
CSA Std C22.2 # 61010.1
e :
c: S = EMC:
Serial
a: S = 50-100 mV shunt
E = Ethernet
Communication:
I = external hall(Ethernet)
effect (20 mA)
Connection:
10/100Base-T
N = None
V
= external hall RJ45,
effect
(5 Vdc)
Protocols:
Modbus TCP or BACNet/IP or SNMP
D= 0-5A direct or DNP 3.00 over IP
d: M= Modbus
Limits:
Not available for 800Vdc range
B = FCC:
BACnet
b: 1
= 50 Vdc
L = Other:
LonWorks
2
= 150
Vdc Outputs: - Optional
Pulse
/ Status
S = SNMP
Type:
Potential Free, N.O. Solid State Relay
4
= 400 Vdc
Pulse
100 mS default
D = DNP 3.0
8
= Width:
800 Vdc
Min 50 mS, User configurable up to 10 Seconds
N = None
Max 10 Pulses per Second
Pulse Rate:
Max On-Resistance:
1 Pulse / 1 kWh default, User configurable
30 ohm
Max switching current:
Connection:
120mA (350mA for 10mS)
Isolated Pin-Pair (Output 3, Outputs 1 and/or 2)
N = Not fitted
IEC 61000-6-3 Emissions,
PImmunity,
= 1 x Digital
output IEC 61000-6-2
IEC 61000-4-2,
IEC(PhotoMos
relay)
IEC 61000-4-3,
61000-4-4,
IEC 61000-4-5,
IEC261000-4-6,
A=
x Digital Inputs IEC 61000-4-8,
61000-4-11 free) &
IEC(Potential
1 x ADigital
CISPR
22/FCC 15 class
Output (PhotoMos relay)
IEC60688
III –3280Vac
= 3 /x485Vac
Digital output
Category
(PhotoMos relay)
** Other configurations
available
CONNECTIONS
(SHUNT OR DIRECT)
Max switching voltage: 240Vac
Current Measurement
Counter
/ Status Inputs: - Leg
Optional
in NEGATIVE
Type:
Dry Contact
(recommended)
Min Pulse Width:
50mS, Max 10 Pulses per Second
Max Current/Voltage:
15mA / 6V
Connection:
2 Pin-Pairs (Inputs 1 and/or 2)
Pending
UL Std 61010.1
CSA Std C22.2 # 61010.1
EMC:
IEC 61000-6-3 Emissions,
Readings:
IEC 61000-6-2 Immunity, IEC 61000-4-2,
IEC 61000-4-3, Volts
IEC 61000-4-4,
IEC 61000-4-5, Amps
IEC 61000-4-6,
IEC 61000-4-8, IEC 61000-4-11
FCC:
Other:
14R3
DC INPUT
+
+
Power +
CISPR 22/FCC 15 class A
Energy +
IEC60688
DTS DCCategory III – 280Vac / 485Vac
FCC:
CISPR 22/FCC 15 class A
Other:
IEC60688
Category III – 280Vac / 485Vac
f
-
g
Aux Supply
Current Range
f:1=12 Vdc
g: Amperage of (120-400 Vdc)
Blank: if no external sensor supplied
3=24 Vdc
5=48 Vdc
N= self-powered sensor
1.38”
DIMENSIONS
4.73”
STATUS
PULSE
LOAD
4.73”
+
DC
ETL listing:
Designed to:
IEC 61000-6-3 Emissions,
IEC 61000-6-2 Immunity, IEC 61000-4-2,
IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6,
IEC 61000-4-8, IEC 61000-4-11
SHUNT
+
LOAD
SHUNT
Standards &
Safety:
EMC:
1.38”
Current Measurement
in POSITIVE Leg
Inputs: - Optional
Dry Contact
50mS, Max 10 Pulses per Second
15mA / 6V
2 Pin-Pairs (Inputs 1 and/or 2)
Standards & Safety:
ETL listing:
Pending
Designed to:
UL Std 61010.1
CSA Std C22.2 # 61010.1
Communication: (Ethernet)
Connection:
RJ45, 10/100Base-T
Protocols:
Modbus TCP or BACNet/IP or SNMP
or DNP 3.00 over IP
Limits:
Not available for 800Vdc range
Case Material:
MODEL
NUMBER BUILDER*
Protection:
Dimensions:
Pulse / Status Outputs: - Optional
Type:
Potential Free, N.O. Solid State Relay
Pulse Width:
100 mS default
Min 50 mS, User configurable up to 10 Seconds
Max 10 Pulses per Second
Pulse Rate:
1 Pulse / 1 kWh default, User configurable
Max On-Resistance:
30 ohm
Max switching voltage: 240Vac
Max switching current: 120mA (350mA for 10mS)
Connection:
Isolated Pin-Pair (Output 3, Outputs 1 and/or 2)
3.98”
4.25”
Pluggable screw terminals suitable for
12AWG stranded wire (2.5mm2)
Self-extinguishable, V0 plastic
Nema 1 (IP40)
4.73”(120mm) H x 4.25”(108mm) D x
1.38”(35mm) W
Communication: (Ethernet)
Connection:
RJ45, 10/100Base-T
Protocols:
Modbus TCP or BACNet/IP or SNMP
or DNP 3.00 over IP
Limits:
Not available for 800Vdc range
Pluggable screw terminals suitable for
12AWG stranded wire (2.5mm2)
Self-extinguishable, V0 plastic
Nema 1 (IP40)
4.73”(120mm) H x 4.25”(108mm) D x
1.38”(35mm) W
Case Material:
Protection:
Dimensions:
Aux Supply: (Not required for self-powered)
Voltage options:
12Vdc, 24Vdc or 48Vdc
Tolerance:
-25%, + 50%
Burden:
<3VA
Isolation:
1500Vdc
Operating temp:
-4º to 131ºF (-20º to 55ºC)
Storage temp:
-40º to 185ºF (-40º to 85ºC)
Humidity:
5 to 95% R.H. non-condensing
Mechanical:
Connection:
<3VA
1500Vdc
-4º to 131ºF (-20º to 55ºC)
-40º to 185ºF (-40º to 85ºC)
5 to 95% R.H. non-condensing
REMOTE
DC
DC
DC INPUT
DTS DC
Readings:
Volts –
Amps –
Power +
Energy +
Call Toll Free: 877-PQ-SOLNS (877-777-6567)
Fax (425) 799-4780
email: info@measurlogic.com
Distributor:
* Model dependent
Technical details subject to change
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising