pilot t one detection module vx-200sp-2 impedance

pilot t one detection module vx-200sp-2 impedance
INSTALLATION MANUAL
VX-2000 series
PILOT
T ONE
DETECTION
MODULE
PILOT TONE
DETECTION
MODULE
WITH ANC VX-200SP-2
VX-200SPANC
IMPEDANCE DETECTION MODULE VX-200SZ-2
Thank you for purchasing TOA's VX-2000 series plug-in modules.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
TABLE OF CONTENTS
1. GENERAL DESCRIPTION
.......................................................................3
2. HANDLING PRECAUTIONS
...................................................................3
3. MAXIMUM SYSTEMEXAMPLE
3.1. Block Diagram
.............................................................................................4
.......................................................5
3.2. Maximum System Configuration Table
4. NOMENCLATURE AND FUNCTIONS
Pilot Tone Detection Module with ANC VX-200SPANC
.....................................6
5. SETTINGS
5.1. Gain ratio setting .............................................................................................8
5.2. Response time setting ....................................................................................9
5.3. Sensor sensitivity setting ..............................................................................10
5.3.1. Setting with ANC volume ....................................................................10
5.3.2. ANC Sensor sensitivity adjustment switch [SW500] ...........................11
5.3.3. Check output signal form EXT.IN or VX-2000SF ................................11
5.4. software setting ............................................................................................12
6. SPEAKER LINE FAILURE DETECTION METHODS
Pilot Tone Detection Method
...............................................................................13
7. INSTALLING MODULES (VX-200SPANC)
IN THE VX-200SF FRAME .......................................................................14
8. CONNECTIONS
8.1. VX-200SPANC Connection to Power Amplifier and Speakers ...................15
8.2. VX-200SPANC Connection to External Attenuator .....................................16
8.2.1. 3-wire system connection ....................................................................16
8.2.2. 4-wire system connection ....................................................................16
8.3. VX-200SPANC Connection
to ceiling mount microphone[AN-9001] (option) ...........................................16
8.4. VX-200SPANC Connection to External equipment ......................................16
9. LIST OF CONNECTION CABLES
.........................................................17
10. CABLE CONNECTIONS TO RJ45 CONNECTORS ......................18
11. BLOCK DIAGRAM
11.1. Pilot Tone Detection Module With VX-200SPANC .....................................19
11.2. ANC card ...................................................................................................21
12. SPECIFICATIONS
.....................................................................................21
2
1.GENERAL DESCRIPTION
[VX-200SPANC]
• The VX-200SPANC is an audio signal output module of the VX-2000 system with speaker line pilot tone
detection. This module is to be mounted in the VX-2000SF Surveillance Frame and detects speaker line short
circuits, open circuits by monitoring for the presence of a pilot signal, and ground fault.
• The ANC Function automatically adjusts the amplifiers output volume in response to the change in ambient noise
level. The output volume changes as the ambient noise level goes above the set reference level.
2. HANDLING PRECAUTIONS
• Do not install the unit in locations exposed to the direct sunlight or heaters, as the unit could be deformed or
discolored.
• Avoid installing or storing the unit in dusty or humid locations, as doing otherwise could cause the unit's
failure.
• Keep the unit as far away as possible from a fluorescent lamp, digital equipment, PC or other equipment
which generate high frequency noise.
• Because each unit is not "hot-pluggable," the system needs to be shut down when it is installed or removed.
For turning the system power off, refer to the VX-2000 series Instruction manual, p. 3-11.
3
3. MAXIMUM SYSTEM EXAMPLE
3.1. Block Diagram
The following block diagram shows the maximum sized system that can be assembled with the VX-2000
Series.
VX-2000
VX-2000SF No.1
RM-200XF + RM-210 x 10
VP-2421
VP-200VX
SF-1
Standby Amplifier
VP-2064
VX-200XR
RM-200X + RM-210 x 9
VX-200XR
VX-200SZ
VP-200VX
VX-200SZ
VP-200VX
VX-200SZ
VP-200VX
VX-200SZ
VP-200VX
VX-200SZ
VP-200VX
VX-200SP or
VX-200SPANC
VP-200VX
VX-200SP or
VX-200SPANC
VP-200VX
VX-200SP or
VX-200SPANC
VP-200VX
VX-200SP or
VX-200SPANC
VP-200VX
ZONE 1
ZONE 2
ZONE 3
ZONE 4
VP-2122
RM-200XF + RM-210
RM-200X + RM-210
VX-200XR
ZONE 5
ZONE 6
VP-2241
RM-200XF + RM-210
RM-200X
ZONE 7
VP-2122
VX-200XR
ZONE 8
ZONE 9
RM-200X + RM-210
RM-200XF
VX-200XR
VP-2421
VX-200SP or
VX-200SPANC
ZONE 10
VP-200VX
VX-2000SF No.2
PM-660U
VX-200XI
VX-2000SF No.3
VX-2000SF No.4
Cassette Player
U-01R
CD Player
U-01R
SF-5
Standby Amplifier
VX-2000SF No.5
VP-2241
VP-200VX
VP-2241
EV-200 No.1
VX-200SZ-2
EV-200 No.2
Chime
Internal Timer
x 16
x 16
ZONE 41
VP-200VX
VP-2064
VX-200SZ-2
VP-200VX
VX-200SZ-2
VP-200VX
VX-200SZ-2
VP-200VX
VX-200SZ-2
VP-200VX
ZONE 42
ZONE 43
ZONE 44
Control Input x 16
Control Output x 16
ZONE 45
EOL
VP-2122
VX-200SP-2
VP-200VX
VX-200SP-2
VP-200VX
ZONE 46
EOL
ZONE 47
EOL
VP-2241
VX-200SP-2
ZONE 48
VP-200VX
VX-200SI
x 16
VX-200SO
x 16
4
3.2. Maximum System Configuration Table
Component
Maximum No. of Units
Input Source Equipment
RM-200XF
RM-200X
4 units
4 units in total of 8 units in total 18 units in total of
4 units ("Emergency" type) Emergency-set models of both models all Input Source
Equipment
8 units ("General" type)
Paging Microphone and Music
Sources (Cassette, CD, etc.)
8 units
EV-200
2 units
Chime (internal)
1 unit
RM-200XF's and RM-200X's Function Key Extension
RM-210
10 units (115 function keys) per RM-200XF
315 function keys per system
9 units (115 function keys) per RM-200X
VX-2000
VX-2000
1 unit
Input Module (to be installed in VX-2000)
VX-200XR
VX-200XI
900 module
8 units in total of all Input Modules
Usable 900 modules: M-01F, M-01M, M-01P, M-01S, M-01T, M-03P, M-51F,
M-51S, M-51T, M-61F, M-61S, M-61T, U-01F, U-01P,
U-01R, U-01S, U-01T, U-03R, U-03S, U-61S, and U-61T
VX-2000SF
VX-2000SF
5 units
SF Module (to be installed in VX-2000SF)
VX-200SP
50units
VX-200SP
50 units
VX-200SP-2
50units
VX-200SP-2
50 units
VX-200SPANC
50units
VX-200SZ
50 units
VX-200SZ
50units
VX-200SZ-2
50 units
VX-200SZ-2
50units
VX-200SI
7 units
units
VX-200SI
7
VX-200SO
7 units
50 units in total of all SF Modules
(10 units per VX-2000SF)
Optional Equalizer Card (to be installed in VX-200SP, VX-200SP-2, VX-200SZ and VX-200SZ-2)
VX-200SE
50 units
Control Input
VX-2000
16 inputs
(as standard equipment)
VX-200SI
112 inputs (7 units)
128 inputs in total
Control Output
VX-2000
16 outputs
(as standard equipment)
VX-200SO
112 outputs (7 units)
Power Amplifier
128 outputs in total
Note: The number and type of power amplifiers should be determined
depending on the required speaker output for each zone.
VP-2064 (4 ch)
VP-2122 (2 ch)
VP-2241 (1 ch)
VP-2421 (1 ch)
50 channels (50 zones)
Standby Amplifier
5 channels (1 channel per VX-2000SF)
Power Amplifier Input Module
VP-200VX
Power Supply
5
55 units in total of modules installed in Power and Standby Amplifiers
Note: Necessary power capacity should be calculated based on total system
specifications.
VX-2000DS
10 units
2 units per VX-2000SF
VX-200PS
30 units
3 units per VX-2000DS
Battery
40 units
2 or 4 units per VX-2000DS
4. NOMENCLATURE AND FUNCTIONS
lnstall this module in the VX-2000SF Surveillance Frame to detect speaker line short circuits, open circuits by
monitoring for the presence of a pilot signal, and ground fault.
Please equate this module as the VX-200SP when setting it on the PC software.
[Side]
[Front]
9
8
VX-200SPANC
ANC
MAX.
PA LINK
MIN.
1
5
SW100
H
C
4
N2
EXT. IN
C
ATT CTRL
N1
C
SP OUT
H
2
SW500
H
C
SW501
PA
IN
STANDBY
PA BUS
6
7
3
1. Power amplifier link connector [PA LINK]
This RJ45 connector connects to the PA LINK
connector of the VP-200VX Power Amplifier input
module
Both LEDs on this connector are not used.
2. VX-200SPANC plug-in screw connector
Signal lines to be connected are shown below:
• Line monitor input [LINE MONITOR]
Monitors connected speaker lines.
Connect by wiring from the speaker line end.
• External attenuator control[ATT CTRL]
Permits connection of a 3- or 4-wire system
attenuator.
For the attenuator connection, refer to P. 16
• Speaker output [SP OUT]
Connects to the speaker.
• Power amplifier input [PA IN]
Connects to the power amplifier’s speaker
output terminal.
3. Standby amplifier bus connector
[STANDBY PA BUS]
Connects to all outputs of a single VX-2000SF unit
to be switched over to the standby amplifier when
the power amplifier fails. For details, refer to p.9-7
Standby Amplifier Connection.
4. Sensor/EXP input connector
Plug-in screw connector:8pins
Signal&control lines to be connected are shown below:
• Sensor input [SENSOR]
Connects to ceiling mount microphone 'AN-9001' (option).
Electronically balanced(H:hot,C:cold,E:earth)
Sensitivity :-38,-32,-26,-20,-14,-8,-2,-38 to-10dB*(selectable/
DIP switch)
→For details, refer to p.10
The phantom power of +17V DC is supplied.
Adapted model:Ceiling mount microphone : AN-9001 (Option)
• EXT.input [EXT.IN]
Electronically balanced (H:hot,C:cold,E:earth)
Sensitivity:-20dB/-10dB
10kΩ
Note: When CTRL terminal is open, this input is invalid.
*0dB=1V
• EXT.control [CTRL]
When this terminal (+,-) is short-circuit, EXT input is in operation
and mute the signal from VX-2000SF AUDIO LINK IN.
While the terminal is short-circuit, ANC function is not activated.
While the terminal is open-circuit, ANC function is activated
and EXT input is not in operation.
No-voltage make contact input(+,-)
Open voltage:DC5V or less, Short-circuits :5mA or less
6
5. ANC Sensor sensitivity adjustment volume&Indicator
Adjusts the input sensitivity of SENSOR input.
For details, refer to p.10
6. ANC Sensor sensitivity adjustment switch [SW500]
Adjusts the input sensitivity of SENSOR input.
For details, refer to p.11
7. Response time setting switch [SW501]
Adjusts the response time of ANC function
Attack time = 2sec.,10sec.,1min.
Release time 30sec.,1min.,5min.
For details, refer to p.9
8. Gain ratio setting switch [SW100]
Adjusts the gain ratio of ANC function.
Ambient noise vs. Output signal level
Select the ratio of ambient noise vs. output signal level with this slide switch to (3:3) or (3:6).
9.EXT.input sensitivity setting [CN1]
header “ON” :-20dBV (factory setting)
header “OFF” :-10dBV
7
5.SETTINGS
5.1.Gain ratio setting
Adjust the ratio of ambient noise level variation to output level variation.
Adjustable range= 3:3 or 3:6
Slide switch 'SW100'
SW100
3:6
3:3
SW100
EXT. IN
SW500
SW501
For example, if the ratio between N (ambient noise) and S (output signal level) is set to 3:3,
the output volume level goes up by 3dB when the ambient noise level increases by 3dB.
Gain step is shown in the following tables.
Note 1. Default (presetting) N:S=3:3
Note 2. Maximum gain : +21dB (Fixed)
Note 3. Minimum gain : 0dB (Fixed)
8
5.2.Response time setting
Set the average time required to detect the ambient noise levels with the sensor microphone.
Adjustable range is as follows.
Attack time 2sec.,10sec.,1min.
Release time 30sec.,1min.,5min.
NO
1 2 3 4 5 6 7 8
NO
1 2 3 4 5 6 7 8
ECE
ECE
SW100
EXT. IN
SW500
SW501
Dip switch 'SW501'
Note . Default (factory setting)
Attack time 2sec(SW501 NO.1:ON)
Release time 30sec(SW501 NO.3:ON)
9
5.3.Sensor sensitivity setting
5.3.1.Setting with ANC volume
Adjust the input sensitivity for SENSOR input with ANC volume on front panel.
ANC
VX-200SPANC
ANC
MAX.
MAX.
PA LINK
MIN.
MIN.
ANC volume
(Please use 0.5mm~0.7mm ( - )screw driver)
H
C
C
N2
ATT CTRL
N1
C
SP OUT
H
H
C
PA
IN
STANDBY
PA BUS
Note.
Adjustment procedure is as below.
Initial condition : EXT terminals : Open, no audio signal from VX-200SF
When the audio signal is fed from VX-2000SF AUDIO LINK IN, or the CTRL terminal is short-circuit, the
noise input from SENSOR is terminated. In this condition, correct adjustment is not available.
Adjust the sensor input level through monitoring ANC indicator. When the Sensor input level over
the threshold level, ANC indicator turns on.
dB
dB
dB
Noise range = 21dB(Fixed)
Noise level that you want to
start to control
Ambient noise level
SENSOR level
Output level(gain ratio=3:6)
Output level(gain ratio=3:3)
10
5.3.2. ANC Sensor sensitivity adjustment switch[SW500]
NO
1 2 3 4 5 6 7 8
NO
1 2 3 4 5 6 7 8
ECE
ECE
SW100
EXT. IN
SW500
SW501
SENSOR input sensitivity
Position
5.3.3.Check output signal from EXT.IN or VX-2000SF
When the audio signal is fed from VX-2000SF, or the CTRL terminal is short-circuit, the noise input from
SENSOR is terminated. At this configuration, the function of ANC indicator is changed to output indicator
from sense indicator.
NOTE : It takes about 5 seconds for the change of the function from output indicator to sense indicator.
[Function of ANC indicator]
Condition
Operation
Indicator for Adjustment
Indicator for Output gain
CTRL(+,-):open circuits AND
No audio Signal from VX-2000SF AUDIO LINK IN
CTRL(+,-):short circuits OR Available
audio signal from VX-2000SF AUDIO LINK IN
Under threshold level : OFF
Over threshold level : Light on
gain=0dB : OFF
+3dB-Under maximum gain : Light on
Maximum gain : Flashing
Confirm the output audio signal in the case of the maximum ambient noise and minimum ambient noise
through monitoring the output indicator.
・Adjust the input signal level not distorted and not make foldback in the case of
maximum ambient noise level. If output indicator is flashing, the gain of this unit is +21 dB.
・Confirm the output audio signal is appropriate level at minimum ambient noise condition.
If output indicator is off, the gain of this unit is 0 dB.
11
5.4.Software setting
For the setting instructions, refer to P.7-15 3)"Pilot tone module"(PC software offline settings).
Tick the EQ checkbox.
3) Pilot Tone Module
Refers to the VX-200SP Pilot Tone Detection module.
Tick this checkbox
• EQ:
When using the VX-200SE Equalizer Card, tick this checkbox.
When using the VX-200SPANC, tick this checkbox.
Note: Set this unit to EQ
12
6. SPEAKER LINE FAILURE DETECTION METHODS
Note
The failure detection functions described here are designed to perform on a 100-volt line of speaker. For the
methods using a 70- or 50-volt line, please consult your TOA dealer.
The VX-200SPANC Pilot Tone Detection module detects speaker line failures by using a pilot tone. A 20kHz failure
detection pilot signal is superimposed on the signal line. To detect speaker line failures, the VX-200SPANC checks
the signal return from the speaker line end to the LINE MONITOR terminal.
[VX-200SPANC Failure detection]
VX-2000SF
Short/open circuit
detection
20 kHz
Pilot Tone
PA LINK
VX-200SPANC
PA IN
Ground fault
detection
SP OUT
LINE MONITOR
End of line
13
7. Installing Module (VX-200SPANC) in the VX-2000SF Frame
Notes
• The slot number and module type to be installed must be identical to those designated by the PC software.
• Equate the VX-200SPANC as VX-200SP when setting them on the PC
software.
• Cover idle slots with the supplied blank panels to prevent dust from getting into the equipment.
Step 1. Align the module with the rails inside the VX-2000SF Frame, then push the module in to plug its
connector strip securely into the VX-2000SF's internal connector.
Step 2. Tighten both the top and bottom screws.
Blank panel
(supplied with the VX-2000SF)
Connect the connector
cable (8P) before insert
the module to the frame.
Machine screw M3 x 6
(supplied with the VX-2000SF)
14
8. CONNECTIONS
8.1. VX-200SPANC Connection to Power Amplifier and Speakers
VP-200VX
[VP-2122 Rear]
DC P OWE R IN
28 V
4.8 A
C H2
C
H
From VX-2000DS'
DC POWER OUT
C H1
P A OUT (S P LINK )
C H1
C
H
P A LINK
C H2
P A LINK
VP-200VX
VX-200SPANC
VX-200SPANC
Cat. 5 STP
PA LINK
LINE MONITOR
SP OUT
PA IN
H
C
H
C
H
C
1
n
Note
After bundling all the speaker shield cables from the individual VX-200SP-2 modules into
one cable at a terminal board, connect the cable to the VX-2000SF's chassis ground.
15
8.2. VX-200SPANC Connection to External Attenuator
8.2.1. wire system connection
VX-200SPANC
LINE MONITOR
ATT CTRL
N1 (NO)
C
N2 (NC )
SP OUT
Attenuator Control (ATT CTRL) relay contact capacity
Withstand voltage: 30 V DC, 250 V AC
Contact current: 7A (DC) or less, 7A (AC) or less
End of line
H
C
H
C
R
N
SP
AT-603 etc.
8.2.2. wire system connection
VX-200SPANC
DC Power
Supply
(+)
(–)
LINE MONITOR
ATT CTRL
SP OUT
N1 (NO)
C
N2 (NC)
End of line
H
C
H
C
Attenuator Control (ATT CTRL) relay contact capacity
Withstand voltage: 30 V DC, 250 V AC
Contact current: 7A (DC) or less, 7A (AC) or less
(–)
(+)
N
SP
Relay
Control
8.3. VX-200SPANC Connection to ceiling mount microphone [AN-9001] (option)
[AN-9001]
H
shielded cable
C
E
NOTE.
Connect the connector
cable (8P) before insert
the module to the frame.
shielded cable
8.4. VX-200SPANC Connection to External Equipment
NOTE.
Connect the connector
cable (8P) before insert
the module to the frame.
shielded cable
[External equipment]
H
shielded cable
Open Voltage: +5V DC
Short-Circuit: 5mA or less
C
E
LINE LEVEL
OUTPUT
switch
16
9. LIST OF CONNECTION CABLES
[VX-200SPANC]
Terminal to Connect
Terminal
Name
Cable Type
Equipment to be Connected to
Equipment
Receptacle
Plug
PA LINK
RJ45 (female)
RJ45 (male)
LINE
MONITOR
Plug-in screw
connector
Unprocessed cable
16 – 24AWG
end
ATT CTRL
Plug-in screw
connector
3-wire: 16 – 24AWG
Unprocessed cable
Unprocessed cable
External attenuator
4-wire: Twisted pair
end
end
cable
SP OUT
Plug-in screw
connector
Unprocessed cable Shielded pair cable
end
16 – 24AWG
Unprocessed cable
Speaker
end
PA IN
Plug-in screw
connector
Unprocessed cable
16 – 24AWG
end
Round or Y terminal
STANDBY
PA BUS
2P VH connector
Round or Y terminal 18AWG
Standby amplifier
Round or Y terminal VP-2064/-2122/
-2241/-2421
STANDBY
PA BUS
2P VH connector
Sensor input
connector
Plug-in terminal
block
17
–
Cable Type
Cat. 5 STP
PCB Cable
18-26AWG
Unprocessed cable Shielded cable
(for sensor input
end
and EXT input)
Plug
RJ45 (male)
Equipment
VP-200VX
Unprocessed cable
VX-200SP-2
end
–
VP-2064/-2122/
-2241/-2421
VX-200SP
VX-200SZ
Unprocessed cable AN-9001
External equipment
end
Terminal
Name
Equipment
Receptacle
PA LINK
RJ45 (female)
SP OUT
Plug-in screw
connector
–
–
Speaker
terminal
Push-in terminal
block
PA OUT
(SP LINE)
2P screw terminal
PA OUT
(SP LINE)
2P screw terminal
STANDBY
PA BUS
–
–
–
10. CABLE CONNECTIONS TO RJ45 CONNECTORS
Connect a RJ45 connector to both ends of the Cat. 5 STP cable and make the following connections:
[ Source to Connect ]
Component
VX-2000
VX-2000
VX-2000SF
VX-2000SF
[ Source to be Connected to ]
Component
Connector Name
Connector Name
DATA LINK
AUDIO LINK OUT
AUDIO LINK OUT
DATA LINK
STANDBY PA LINK
DS-SF LINK 1, 2
PA LINK
VX-2000SF
VX-2000SF
Next VX-2000SF
Next VX-2000SF
VP-200VX
VX-2000DS
VP-200VX
DATA LINK
AUDIO LINK IN
AUDIO LINK IN
DATA LINK
PA LINK
DS-SF LINK
PA LINK
VX-200SP-2
PA LINK
PA LINK
VP-200VX
VP-200VX
PA LINK
PA LINK
VX-200SZ-2
PA LINK
VP-200VX
PA LINK
VX-2000SF
VX-2000SF
VX-200SP
VX-200SZ
[ RJ45 connector pin assignment ]
RJ45 Pin No.
Colour*
1
Orange / white
2
Orange
3
Green / white
4
Blue
5
Blue / white
6
Green
7
Brown / white
8
Brown
Shield
Shield
Pair
*Differs from cable makers. In
wiring, refer to the cable
specifications for Colour
RJ45 connector
Pin No.
RJ45 connector
1
2
3
4
5
6
7
8
Shield
RJ45 connector
Cat. 5 STP cable
18
19
SA2
Ground Fault Detection
H
Standby
Amplifier Bus
Audio Monitor Bus
Pilot Tone Monitor
Bus 2 (40 kHz)
Pilot Tone Monitor
Bus 1 (20 kHz)
Pilot Tone Bus 3
40 Hz
Detection*
C
H
C
H
C
H
N2
C
N1
ANC Card
Pilot Tone Bus 2
20 kHz
BA
LA
C
SA1
ON
RM-200XF's CPU SW
OFF
Pilot Tone Bus 1
40 kHz
Audio Bus 1
Audio Bus 2
Audio Bus 3
Audio Bus 4
MAIN PCB
C
H
Standby amplifier
Bus Connector
[STANDBY PA BUS]
Power Amplifier Input [PA IN]
Speaker Output [SP OUT]
External Attenuator Control
[ATT CTRL]
Line Monitor Input
[LINE MONITOR]
Overheat
Status Input
DC Fuse Blowout
Detection Input
Standby
Control Output
Audio Monitor
Output (balanced)
Audio Signal
Output (balanced)
Power Amplifier
Link Connector [PA LINK]
11. BLOCK DIAGRAM
11.1. Pilot Tone Detection Module With VX-200SPANC
11.2. ANC card
CTRL
(+,-)
---SETTING--[EXT. IN GAIN]
-20dB/-10dB
CN1
(OPEN CIRCUIT 'CTRL'
→EXT.IN IS MUTED.)
EXT.IN
(H,C,E)
-20dBV,
10kΩ
-20dBV
SW100
MUTE
(SHORT CIRCUIT 'CTRL'
→SWITCH TO
HIGH PASS FILTER)
------SWITCHER-----0dBV HIGH PASS FILTER(40kHz)
⇔
THROUGH
SIG_IN
(H,E)
0dBV
FROM
MAIN PCB
0dBV
---SETTING--[GAIN RATIO]
3:3 or 3:6
VCA
SIG_OUT
TO MAIN PCB
LEVEL
DETECTOR
PHANTOM
POWER
+17DC
JP11
SENSOR
(H,C,E)
A-FILTER
SW500
VR300
FROM
VX-200SP
RECOGNITION
OF ANC CARD
RESPONSE TIME
CONTROL
RECTIFIER
------SETTING-----[SENSOR SENSITIVITY]
NO.1 ON:-38dB
NO.2 ON -32dB
NO.3 ON:-26dB
NO.4 ON:-20dB
NO.5 ON:-14dB
NO.6 ON: -8dB
NO.7 ON: -2dB
NO.8 ON:-38dB TO -10dB
(ADJ.FRONT
VOLUME:VR300)
LED CONTROL
SW501
------SETTING----[ATTACK TIME]
NO.1 ON: 2SEC
* Off broadcast : ANC Indicator
NO.2 ON:10SEC
(Gain) Under Thresh : OFF
NO.2&3 OFF:1MIN
Above Thresh To max : ON
[RELEASE]
* On broadcast : Output Indicator
NO.4 ON:30SEC
(Gain) 0dB : OFF
NO.5 ON: 1MIN
(Gain) +3dB to below +21dB : ON
NO.4&5 OFF:5MIN
(Gain) +21dB : Flashing
ANC CARD
20
12. SPECIFICATIONS
Power Source
Current Consumption
Power Amplifier Link
Line Monitor
External Attenuator
Control output
Speaker Output
Power Amplifier Input
EXT.input
EXT.input control[CTRL]
Sensor input
ANC
CARD
Ambient Noise
Control Function
Supplied from VX-2000SF
Under 130mA
RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241, or
VP-2421 Power Amplifier
Twisted-pair straight cable (TIA/EIA-568A standard)
Plug-in screw connector
Applicable cable diameter: AWG 16 – AWG 24
Plug-in screw connector, relay, no-voltage make contact output,
transfer type, withstand voltage: 30 V DC, 250 V AC,
contact current: Under 7 A (DC), under 7 A (AC)
Applicable cable diameter: AWG 16 – AWG 24
Plug-in screw connector
Applicable cable diameter: AWG 16 – AWG 24
Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241, or
VP-2421 Power Amplifier
Applicable cable diameter: AWG 16 – AWG 24
Removable terminal block (8 pins)
Electronically balanced(H,C,E)
Sensitivity:-20dB*/-10dB*
10kΩ
Applicable cable diameter : AWG 18 - AWG 26
Removable terminal block (8 pins)
No-voltage make contact input(+,-)
Open voltage: +5V DC,Short-circuit :5mA OR less
Applicable cable diameter : AWG 18 - AWG 26
Removable terminal block (8 pins)
Electronically balanced(H,C,E)
Sensitivity:-38,-32,-26,-20,-14,-8,-2,-38dB to-10dB*(selectable/DIP switch)
Phantom power (+17V DC)
Applicable cable diameter : AWG 18 - AWG 26
Output signal level control :
0 to +21dB
Step=3dB(When gain ratio=3:3),6dB(When gain ratio=3:6)
Response time(selectable/DIP switch) :
Attack time=2sec.,10sec.,1min.
Release time=30sec.,1min.,5min.
Gain ratio setting(Ambient noise: Output signal level) :
3:3,3:6(selectable/slide switch)
ANC’s thresh
level adjustment
Volume(Front Panel)
ANC’s indicator
LED indicator(green)
Fault Detection System
Finish
Dimensions
Weight
Applicable Model
*0dB=1V
Short circuit, open circuit (pilot tone detection method), ground fault
Panel: Surface-treated steel plate
30.5 (w) x 132.6 (h) x 290.3 (d) mm
520 g
VX-2000SF
Note: The design and specifications are subject to change without notice for improvement
• Accessory Plug-in screw terminal ( 9P ).............1
( 8P ).............1
• Option Ceiling mount microphone:AN-9001
21
D33-12-026-2A
Was this manual useful for you? yes no
Thank you for your participation!