gsi audera™ aep/caep - Grason

gsi audera™ aep/caep - Grason
GSI AUDERA AEP/CAEP
™
Auditory Evoked Potentials
Product
Specifications
•Test Types: AEP, ECochG, Cortical AEP, AMLR,
EABR
a)Main unit includes isolation transformer/
power supply which provides isolated mains power only for supported notebook computer and inkjet printer models.
•Transducers: Insert earphones, TDH Headphones,
Bone vibrator, Loudspeaker
•Protocols: Default and customer specified
•Marker Sets: Default and customer specified
•Reports: Color, Black/White or PDF
Stimulus Specifications:
•Stimulus Types: Click, tone burst, tone pip
CE-Chirp® and CE-Chirp Octave Bands
•Stimulus Polarity: Condensation, Rarefaction
and Alternating
•Masking Types: Absolute or stimulus relative
•GSI Audera Service Manual
•Dimensions: 12.99”(W) x 10.62”(D) x 1.67”(H)
•GSI Audera Desktop Computer
•Weight: 7.05lb
Environmental Limits:
•GSI Audera Laptop Power Kit (cables to power
through base unit)
•Operating Temp: 50° F to 104° F
Relative Humidity: 30 to 75%, non-condensing
•GSI Audera Isolation Transformer (for customer
desktop systems)
•Storage Temp: -40° F to 158° F
Relative Humidity: 10 to 100%, non-condensing
•GSI Audera EABR cable
•Intensity: 0 to 130 dB SPL
CPU Recommendation
•Repetition rates: 0.2 – 100 depending on modality
•Operating System: Windows 7 Professional
(32 bit & 64 bit), Windows XP Pro (SP3),
Vista Business (SP2)
•High Pass Filtering: RC or Digital Butterworth
•Low Pass Filtering: Butterworth or Digital linear
phase
•Processor: 1.6 GHz
GSI Audera Amplifier:
•Minimum RAM: 2 GB
•Dimensions: 3.93”(W) x 7.48”(D) x 1.57”(H)
•Storage: 11 GB Hard Drive
•Weight: .94 lb
•Additional Storage: CD R/W drive
•Interface To Main Unit: Proprietary high-speed,
serial digital
•USB Ports: 2
•Number of Channels: 2 Isolated (type BF) for
patient safety
•Graphics: 1024 x 768 pixels (1280 x 1024 for China,
Japan, Korea)
•Electrode inputs: Differential
Supplied Accessories
•Electrode connectors: 5 DIN 42802 safety
connectors
•GSI Audera Main Unit
•Input Impedance: >1000 MW
•GSI Audera 2-Channel Amplifier with 9’ cable
•Frequency Response: 0.2-10,000 Hz
•GSI Audera AEP/CAEP Software Application or
Licensing key to activate
GSI Audera Main Unit
Optional Accessories
b) Main unit provides isolated power to Amplifier/Digitizer or ProbeUnit.
•GSI Audera Reference Manual
•GSI Audera AEP/CAEP User’s Manual
•GSI Audera Laptop Computer
Related Part Numbers
•GSI Audera AEP/ASSR System . . . . . . 2001-9700
•GSI Audera AEP/DPOAE System . . . . 2001-9705
•GSI Audera ASSR/DPOAE System . . . 2001-9710
•GSI Audera AEP/ASSR/DPOAE
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2001-9715
•GSI Audera AEP only System . . . . . . . 2001-9720
•GSI Audera ASSR only System . . . . . . 2001-9725
•GSI Audera DPOAE only System . . . . 2001-9730
•GSI Audera ASSR Upgrade
with Amplifier . . . . . . . . . . . . . . . . . . . . . . 2001-9661
•GSI Audera ASSR Upgrade
without Amplifier . . . . . . . . . . . . . . . . . . . 2001-9662
•GSI Audera AEP Upgrade
with Amplifier . . . . . . . . . . . . . . . . . . . . . . 2001-9663
•GSI Audera AEP Upgrade
without Amplifier . . . . . . . . . . . . . . . . . . . 2001-9664
•GSI Audera DPOAE Upgrade . . . . . . . . 2001-9665
Quality System
•Computer Interface: USB - Type I
•Insert Earphones with 9’ cable
•Trigger Controls Input/Output: Standard TTL
logic level
•GSI Audera Loop-back cable
•Mains Power Supply: 115V, 110V, or 230V;
50-60 Hz
•Electrodes, 10mm cup, 12 pk
Compliance/Regulatory Standards
•Electrode Linker
Designed, tested and manufactured to meet
the following domestic (USA), Canadian,
European and International Standards:
•Power Consumption: 115W, excluding printer
•Electrodes, 6mm cup, 12 pk
•Disposable side snap electrodes, 25 pk
•Electrode Leads, Snap, 5 pk
•NuPrep Gel, 4 oz. tube
•Ten 20 Paste, 4 oz. tube
•UL 60601-1 American Standards for Medical
Electrical Equipment
•Infant eartips, 3.5mm, 20 pk
•IEC 60601-1, EN 60601-1 International
Standards for Medical Electrical Equipment
•Infant eartips, 4.0mm, 20pk
•CSA C22.2 # 601-1-M90
•3A foam eartips, 10mm, 100pk
•Medical Device Directive (MDD) to comply with
“EC Directive” 93/42/EEC
•3A foam eartips, 13mm, 100pk
Setting The Clinical Standard
•Manufactured, designed, developed and
marketed under ISO 13485 certified quality
system.
www.grason-stadler.com
Grason-Stadler, 7625 Golden Triangle Drive, Suite F, Eden Prairie MN 55344
800-700-2282 • 952-278-4402 • fax 952-278-4401 • e-mail info@grason-stadler.com
P/N #2001-0321 Rev. B
Isolated Power:
©GSI Grason-Stadler, 2013
General Specifications
GSI AUDERA ASSR
™
Auditory Steady State Response
Product
Specifications
•Transducers: Insert earphones, TDH
Headphones, Bone vibrator, Loudspeaker
a)Main unit includes isolation transformer/
power supply which provides isolated mains power only for supported notebook computer and inkjet printer models.
•Protocols: Default Asleep and Awake protocols
or customer specified -- Estimated Audiogram
relies on default protocols
b)
Main unit provides isolated power to Amplifier/Digitizer or ProbeUnit.
Optional Accessories
•Dimensions: 12.99”(W) x 10.62”(D) x 1.67”(H)
•GSI Audera Laptop Computer
•Reports: Color, Black/White or PDF
•Weight: 7.05lb
•GSI Audera Desktop Computer
Stimulus Specifications:
Environmental Limits:
•Stimulus Types: AM/FM
•Operating Temp: 50° F to 104° F
Relative Humidity: 30 to 75%, non-condensing
•GSI Audera Laptop Power Kit (cables to power
through base unit)
•Display: ASSR Thresholds, Estimated
Audiogram, Results Summary, Trials Done
•Masking Types: Absolute or stimulus relative
•Intensity: -10 to 130 dB HL
•Carrier Frequency: 250 – 8000 Hz
•Modulation Frequency: 20 – 200 Hz depending
on carrier frequency
•Storage Temp: -40° F to 158° F
Relative Humidity: 10 to 100%, non-condensing
CPU Recommendation
•FM Modulation: 0 – 15%
•Operating System: Windows 7 Professional
(32 bit & 64 bit), Windows XP Pro (SP3),
Vista Business (SP2)
•Relative Angle: 0 – 359 degrees
•Processor: 1.6 GHz
GSI Audera Amplifier:
•Minimum RAM: 2 GB
•Dimensions: 3.93”(W) x 7.48”(D) x 1.57”(H)
•Storage: 11 GB Hard Drive
•Weight: .94 lb
•Additional Storage: CD R/W drive
•Interface To Main Unit: Proprietary high-speed,
serial digital
•USB Ports: 2
•AM Modulation: 0 – 100%
•Number of Channels: 2 Isolated (type BF) for
patient safety
•Graphics: 1024 x 768 pixels (1280 x 1024 for China,
Japan, Korea)
•GSI Audera Service Manual
•GSI Audera Isolation Transformer (for customer
desktop systems)
Related Part Numbers
•GSI Audera AEP/ASSR System . . . . . . 2001-9700
•GSI Audera AEP/DPOAE System . . . . 2001-9705
•GSI Audera ASSR/DPOAE System . . . 2001-9710
•GSI Audera AEP/ASSR/DPOAE
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2001-9715
•GSI Audera AEP only System . . . . . . . 2001-9720
•GSI Audera ASSR only System . . . . . . 2001-9725
•GSI Audera DPOAE only System . . . . 2001-9730
•GSI Audera ASSR Upgrade
with Amplifier . . . . . . . . . . . . . . . . . . . . . . 2001-9661
•GSI Audera ASSR Upgrade
without Amplifier . . . . . . . . . . . . . . . . . . . 2001-9662
•Electrode inputs: Differential
Supplied Accessories
•Electrode connectors: 5 DIN 42802 safety
connectors
•GSI Audera Main Unit
•Input Impedance: >1000 MW
•GSI Audera 2-Channel Amplifier with 9’ cable
•Frequency Response: 0.2 – 10,000 Hz
•GSI Audera ASSR Software Application or
Licensing key to activate
•GSI Audera DPOAE Upgrade . . . . . . . . 2001-9665
GSI Audera Main Unit
•GSI Audera Reference Manual
•GSI Audera AEP Upgrade
with Amplifier . . . . . . . . . . . . . . . . . . . . . . 2001-9663
•GSI Audera AEP Upgrade
without Amplifier . . . . . . . . . . . . . . . . . . . 2001-9664
•GSI Audera ASSR User’s Manual
Quality System
•Computer Interface: USB - Type I
•Insert Earphones with 9’ cable
•Trigger Controls Input/Output: Standard TTL
logic level
•GSI Audera Loop-back cable
•Manufactured, designed, developed and
marketed under ISO 13485 certified quality
system.
•Mains Power Supply: 115V, 110V, or 230V;
50-60 Hz
•Electrodes, 10mm cup, 12 pk
Compliance/Regulatory Standards
•Electrode Linker
Designed, tested and manufactured to meet
the following domestic (USA), Canadian,
European and International Standards:
•Power Consumption: 115W, excluding printer
•Electrodes, 6mm cup, 12 pk
•Disposable side snap electrodes, 25 pk
•Electrode Leads, Snap, 5 pk
•NuPrep Gel, 4 oz. tube
•Ten 20 Paste, 4 oz. tube
•Infant eartips, 3.5mm, 20 pk
•IEC 60601-1, EN 60601-1 International
Standards for Medical Electrical Equipment
•Infant eartips, 4.0mm, 20pk
•CSA C22.2 # 601-1-M90
•3A foam eartips, 10mm, 100pk
•Medical Device Directive (MDD) to comply
with “EC Directive” 93/42/EEC
•3A foam eartips, 13mm, 100pk
Setting The Clinical Standard
•UL 60601-1 American Standards for Medical
Electrical Equipment
www.grason-stadler.com
Grason-Stadler, 7625 Golden Triangle Drive, Suite F, Eden Prairie MN 55344
800-700-2282 • 952-278-4402 • fax 952-278-4401 • e-mail info@grason-stadler.com
P/N #2001-0323 Rev. B
Isolated Power:
©GSI Grason-Stadler, 2013
General Specifications
GSI AUDERA DPOAE
™
Distortion Product Otoacoustic Emissions
Product
Specifications
General Specifications
GSI Audera Main Unit
•Test Types: Distortion Product Otoacoustic
Emissions, Spontaneous OAE, Input/Output
DPOAE
•Computer Interface: USB - Type I
•Protocols: Default Diagnostic and Screening,
Customer Configurable
•Mains Power Supply: 115V, 110V, or 230V;
50-60 Hz
•Display: DPgram, FFT plot, I/Ogram, Signal/
Noise Ratio of selected point, Compare Test
(sequential test comparisons, multiple test,
multiple days)
•Power Consumption: 115W, excluding printer
•GSI Audera Laptop Computer
Isolated Power:
•GSI Audera Desktop Computer
a)Main unit includes isolation transformer/
power supply which provides isolated mains power only for supported notebook computer and inkjet printer models.
•GSI Audera Laptop Power Kit (cables to power
through base unit)
•Frequency: 500 – 12, 000 Hz
•GSI Audera Service Manual
•GSI Audera Isolation Transformer (for customer
desktop systems)
•Level: 20 – 80 dB SPL, in 5 dB steps
b)
Main unit provides isolated power to Amplifier/Digitizer or ProbeUnit.
•Accuracy: ± 3 dB
•Dimensions: 12.99”(W) x 10.62”(D) x 1.67”(H)
•GSI Audera AEP/ASSR System . . . . . . 2001-9700
_ 1.8% at 80 dB SPL, IEC
•Harmonic Distortion: <
711 coupler, 500 – 12,000 Hz
•Weight: 7.05lb
•GSI Audera AEP/DPOAE System . . . . 2001-9705
Environmental Limits:
•GSI Audera ASSR/DPOAE System . . . 2001-9710
•Dynamic Range: 85 dB SPL, IEC 711 coupler,
500-12,000 Hz, F1 & F2 = 65 dBSPL
•Operating Temp: 50° F to 104° F
Relative Humidity: 30 to 75%, non-condensing
•GSI Audera AEP/ASSR/DPOAE
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2001-9715
•Octave Ranges: 500-1000, 1000-2000, 2000-4000,
4000-8000, 8000-12000 Hz
•Storage Temp: -40° F to 158° F
Relative Humidity: 10 to 100%, non-condensing
•GSI Audera AEP only System . . . . . . . 2001-9720
•Points per Octave: 1 – 12 points
Related Part Numbers
•GSI Audera ASSR only System . . . . . . 2001-9725
•GSI Audera DPOAE only System . . . . 2001-9730
•F2/F1 Ratio: 1.1 – 1.8
CPU Recommendation
•Test Time: Varies, depending on test parameters,
environment, and scoring options
Status Indicators:
•Operating System: Windows 7 Professional
(32 bit & 64 bit), Windows XP Pro (SP3),
Vista Business (SP2)
•Probe LED:
•Processor: 1.6 GHz
-Green solid – test in progress
•Minimum RAM: 2 GB
-Yellow solid – seal check in progress
•Storage: 11 GB Hard Drive
-Yellow flashing – test stopped, probe problem/
seal check failed
•Additional Storage: CD R/W drive
•GSI Audera AEP Upgrade
without Amplifier . . . . . . . . . . . . . . . . . . . 2001-9664
•USB Ports: 2
•GSI Audera DPOAE Upgrade . . . . . . . . 2001-9665
OAE Pod/Probe:
•Dimensions: 1.69”(W) x 1.18”(D) x 4.17”(H)
•Graphics: 1024 x 768 pixels (1280 x 1024 for China,
Japan, Korea)
Quality System
•Weight: .44 lb
Supplied Accessories
•Interface to GSI Audera Base: 25 pin D-SUB
connector
•GSI Audera Main Unit
•GSI Audera ASSR Upgrade
without Amplifier . . . . . . . . . . . . . . . . . . . 2001-9662
•GSI Audera AEP Upgrade
with Amplifier . . . . . . . . . . . . . . . . . . . . . . 2001-9663
•Manufactured, designed, developed and
marketed under ISO 13485 certified quality
system.
•GSI Audera Reference Manual
•GSI Audera OAE Probe/Pod with Test Cavity
Compliance/Regulatory Standards
•GSI Audera OAE Calibration CD
Designed, tested and manufactured to meet
the following domestic (USA), Canadian,
European and International Standards:
•GSI Audera DPOAE Software Application or
Licensing key to activate
•GSI Audera DPOAE User’s Manual
•GSI Audera Shoulder Mount Kit
•UL 60601-1 American Standards for Medical
Electrical Equipment
•Eartip Kit, Infant
•IEC 60601-1, EN 60601-1 International
Standards for Medical Electrical Equipment
•Eartip Kit, Child/Adult
•CSA C22.2 # 601-1-M90
•Eartip Kit, Adult
•Medical Device Directive (MDD) to comply with
“EC Directive” 93/42/EEC
•Probe Cleaning Floss & Instructions
Setting The Clinical Standard
•GSI Audera ASSR Upgrade
with Amplifier . . . . . . . . . . . . . . . . . . . . . . 2001-9661
www.grason-stadler.com
Grason-Stadler, 7625 Golden Triangle Drive, Suite F, Eden Prairie MN 55344
800-700-2282 • 952-278-4402 • fax 952-278-4401 • e-mail info@grason-stadler.com
P/N #2001-0322 Rev. B
•DPOAE Stimulus Tones:
Optional Accessories
©GSI Grason-Stadler, 2013
•Reports: Color, Black/White or PDF
•Trigger Controls Input/Output: Standard TTL
logic level
Was this manual useful for you? yes no