Interchassis Redundancy Using Virtual Chassis

Interchassis Redundancy Using Virtual Chassis
Junos® OS
Interchassis Redundancy Using Virtual Chassis
Feature Guide for MX Series Routers
Modified: 2017-05-15
Copyright © 2017, Juniper Networks, Inc.
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000
www.juniper.net
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United
States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All other
trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify,
transfer, or otherwise revise this publication without notice.
®
Junos OS Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Copyright © 2017, Juniper Networks, Inc.
All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the
year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks
software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at
http://www.juniper.net/support/eula.html. By downloading, installing or using such software, you agree to the terms and conditions of
that EULA.
ii
Copyright © 2017, Juniper Networks, Inc.
Table of Contents
About the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Documentation and Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Supported Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Using the Examples in This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Merging a Full Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Merging a Snippet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Documentation Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
Requesting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
Opening a Case with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii
Chapter 1
Understanding How Virtual Chassis Provides Interchassis
Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Interchassis Redundancy and Virtual Chassis Overview . . . . . . . . . . . . . . . . . . . . . 19
Interchassis Redundancy Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Virtual Chassis Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Benefits of Configuring a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Supported Routing Platforms for MX Series Virtual Chassis . . . . . . . . . . . . . . 21
Supported Member Router Combinations . . . . . . . . . . . . . . . . . . . . . . . . 21
Routing Engine Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Chapter 2
Understanding How a Virtual Chassis Works . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Virtual Chassis Components Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Virtual Chassis Master Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Virtual Chassis Backup Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Virtual Chassis Line-Card Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Virtual Chassis Port Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Slot Numbering in the Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Configuration of Chassis Properties for MPCs in the Virtual Chassis . . . . . . . 28
Virtual Chassis Control Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Member IDs, Roles, and Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Global Roles and Local Roles in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . 30
Role Name Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Global Role and Local Role Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Mastership Election in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Switchover Behavior in an MX Series Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . 34
Virtual Chassis Role Transitions During a Global Switchover . . . . . . . . . . . . . 34
Virtual Chassis Role Transitions During a Local Switchover . . . . . . . . . . . . . . 35
Virtual Chassis Role Transitions During Virtual Chassis Formation . . . . . . . . 36
Copyright © 2017, Juniper Networks, Inc.
iii
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
GRES Readiness in a Virtual Chassis Configuration . . . . . . . . . . . . . . . . . . . . . 37
Split Detection Behavior in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
How Split Detection Works in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . 38
Effect of Split Detection on Virtual Chassis Failure Scenarios . . . . . . . . . . . . 38
Virtual Chassis Heartbeat Connection Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Benefits of Configuring a Virtual Chassis Heartbeat Connection . . . . . . . . . . 41
Configuration Requirements for the Heartbeat Connection . . . . . . . . . . . . . . 42
How the Heartbeat Connection Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Heartbeat Connection and Virtual Chassis Failure Conditions . . . . . . . . . . . . 45
Heartbeat Connection Compared to Split Detection . . . . . . . . . . . . . . . . . . . 45
Command Forwarding in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Chapter 3
Configuring a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Preparing for a Virtual Chassis Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Installing Junos OS Licenses on Virtual Chassis Member Routers . . . . . . . . . . . . . 62
Creating and Applying Configuration Groups for a Virtual Chassis . . . . . . . . . . . . 64
Configuring Preprovisioned Member Information for a Virtual Chassis . . . . . . . . . 66
Configuring Enhanced IP Network Services for a Virtual Chassis . . . . . . . . . . . . . 69
Enabling Graceful Routing Engine Switchover and Nonstop Active Routing for
a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Configuring Member IDs for a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Configuring an MX2020 Member Router in an Existing MX Series Virtual
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Switching the Global Master and Backup Roles in a Virtual Chassis
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Deleting Member IDs in a Virtual Chassis Configuration . . . . . . . . . . . . . . . . . . . . . 97
Disabling Split Detection in a Virtual Chassis Configuration . . . . . . . . . . . . . . . . . 98
Example: Replacing a Routing Engine in a Virtual Chassis Configuration for MX
Series 3D Universal Edge Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Example: Deleting a Virtual Chassis Configuration for MX Series 3D Universal
Edge Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Upgrading an MX Virtual Chassis SCB or SCBE to SCBE2 . . . . . . . . . . . . . . . . . . . 123
Preparing for the SCBE2 Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Powering Off the MX Series Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Removing an MX Series Routing Engine from an SCB or SCBE . . . . . . . . . . . 125
Replacing the SCB or SCBE with SCBE2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Installing the MX Series Routing Engine into an SCBE2 . . . . . . . . . . . . . . . . . 126
Powering On the MX Series Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Configuring Member IDs for the Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . 127
Configuring Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Completing the SCBE2 Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
iv
Copyright © 2017, Juniper Networks, Inc.
Table of Contents
Chapter 4
Configuring Virtual Chassis Ports to Interconnect Member Devices . . . . . 133
Guidelines for Configuring Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Configuring Virtual Chassis Ports to Interconnect Member Routers or
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Deleting Virtual Chassis Ports in a Virtual Chassis Configuration . . . . . . . . . . . . . 138
Chapter 5
Configuring Locality Bias to Conserve Bandwidth on Virtual Chassis
Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Locality Bias in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
How Locality Bias Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Locality Bias Percentages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Guidelines for Configuring Locality Bias in a Virtual Chassis . . . . . . . . . . . . . . . . . 143
Configuring Locality Bias for a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Chapter 6
Configuring Class of Service for Virtual Chassis Ports . . . . . . . . . . . . . . . . . 145
Class of Service Overview for Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . . 145
Default CoS Configuration for Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . 145
Supported Platforms and Maximums for CoS Configuration of Virtual Chassis
Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Default Classifiers for Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Default Rewrite Rules for Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . . 147
Default Scheduler Map for Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . 148
Customized CoS Configuration for Virtual Chassis Ports . . . . . . . . . . . . . . . 149
Output Traffic-Control Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Classifiers and Rewrite Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Per-Priority Shaping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Guidelines for Configuring Class of Service for Virtual Chassis Ports . . . . . . . . . . 150
Example: Configuring Class of Service for Virtual Chassis Ports on MX Series 3D
Universal Edge Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Chapter 7
Configuring Redundancy Mechanisms on Aggregated Ethernet Interfaces
in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Link Redundancy in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Module Redundancy in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Chassis Redundancy in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Configuring Module Redundancy for a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . 159
Configuring Chassis Redundancy for a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . 161
Multichassis Link Aggregation in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . 162
Targeted Traffic Distribution on Aggregated Ethernet Interfaces in a Virtual
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Targeted Distribution in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Benefits of Targeted Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Chapter 8
Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D
Universal Edge Routers by Rebooting the Routing Engines . . . . . . . . . . . . 165
Example: Upgrading Junos OS in a Virtual Chassis Configuration for MX Series
3D Universal Edge Routers by Rebooting the Routing Engines . . . . . . . . . . . 165
Copyright © 2017, Juniper Networks, Inc.
v
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Chapter 9
Upgrading Junos OS in an MX Series Virtual Chassis by Performing a
Unified In-Service Software Upgrade (ISSU) . . . . . . . . . . . . . . . . . . . . . . . . . 171
Unified ISSU in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Benefits of Performing a Unified ISSU in an Virtual Chassis . . . . . . . . . . . . . . 171
Prerequisites for Performing a Unified ISSU in a Virtual Chassis . . . . . . . . . . 172
How Unified ISSU Works in a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . 172
Virtual Chassis Role Transitions After a Unified ISSU . . . . . . . . . . . . . . . . . . . 173
Preparing for a Unified ISSU in an MX Series Virtual Chassis . . . . . . . . . . . . . . . . 175
Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified
ISSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Chapter 10
Monitoring an MX Series Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Accessing the Virtual Chassis Through the Management Interface . . . . . . . . . . . 182
Verifying the Status of Virtual Chassis Member Routers or Switches . . . . . . . . . 183
Verifying the Operation of Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Verifying Neighbor Reachability for Member Routers or Switches in a Virtual
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Verifying Neighbor Reachability for Hardware Devices in a Virtual Chassis . . . . . 184
Determining GRES Readiness in a Virtual Chassis Configuration . . . . . . . . . . . . . 185
Viewing Information in the Virtual Chassis Control Protocol Adjacency
Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Viewing Information in the Virtual Chassis Control Protocol Link-State
Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Viewing Information About Virtual Chassis Port Interfaces in the Virtual Chassis
Control Protocol Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Viewing Virtual Chassis Control Protocol Routing Tables . . . . . . . . . . . . . . . . . . . 188
Viewing Virtual Chassis Control Protocol Statistics for Member Devices and
Virtual Chassis Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Verifying and Managing the Virtual Chassis Heartbeat Connection . . . . . . . . . . . 190
Inline Flow Monitoring for Virtual Chassis Overview . . . . . . . . . . . . . . . . . . . . . . . 191
Split Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Syntax of the sampling-instance Statement . . . . . . . . . . . . . . . . . . . . . . . . . 192
FPC Slot Numbers for the Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Managing Files on Virtual Chassis Member Routers or Switches . . . . . . . . . . . . . 193
Virtual Chassis SNMP Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Virtual Chassis Slot Number Mapping for Use with SNMP . . . . . . . . . . . . . . . . . . 194
Example: Determining Member Health Using an MX Series Virtual Chassis
Heartbeat Connection with Member Routers in the Same Subnet . . . . . . . . 196
Example: Determining Member Health Using an MX Series Virtual Chassis
Heartbeat Connection with Member Routers in Different Subnets . . . . . . . 207
Chapter 11
Tracing Virtual Chassis Operations for Troubleshooting Purposes . . . . . . 223
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers . . . 224
Configuring the Name of the Virtual Chassis Trace Log File . . . . . . . . . . . . . . . . . 225
Configuring Characteristics of the Virtual Chassis Trace Log File . . . . . . . . . . . . . 225
Configuring Access to the Virtual Chassis Trace Log File . . . . . . . . . . . . . . . . . . . 226
Using Regular Expressions to Refine the Output of the Virtual Chassis Trace Log
File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
Configuring the Virtual Chassis Operations to Trace . . . . . . . . . . . . . . . . . . . . . . 228
vi
Copyright © 2017, Juniper Networks, Inc.
Table of Contents
Chapter 12
Configuration Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
aggregated-ether-options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
heartbeat-address (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . 234
heartbeat-timeout (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . 235
heartbeat-tos (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
locality-bias (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
logical-interface-chassis-redundancy (MX Series Virtual Chassis) . . . . . . . . . . 238
logical-interface-fpc-redundancy (Aggregated Ethernet Subscriber
Interfaces) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
member (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
network-services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
no-split-detection (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
preprovisioned (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
role (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
sampling-instance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
serial-number (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
targeted-distribution (Static Interfaces over Aggregated Ethernet) . . . . . . . . . . 246
traceoptions (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
virtual-chassis (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
Chapter 13
Operational Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
clear virtual-chassis heartbeat (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . 252
request system software in-service-upgrade (MX Series 3D Universal Edge
Routers and EX9200 Switches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
request virtual-chassis member-id delete (MX Series Virtual Chassis) . . . . . . . . 271
request virtual-chassis member-id set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
request virtual-chassis routing-engine master switch . . . . . . . . . . . . . . . . . . . . . 274
request virtual-chassis vc-port delete (MX Series Virtual Chassis) . . . . . . . . . . . 276
request virtual-chassis vc-port set (MX Series Virtual Chassis) . . . . . . . . . . . . . 278
show chassis network-services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
show interfaces vcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
show services accounting status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
show virtual-chassis active-topology (MX Series Virtual Chassis) . . . . . . . . . . . 303
show virtual-chassis device-topology (MX Series Virtual Chassis) . . . . . . . . . . 305
show virtual-chassis heartbeat (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . 308
show virtual-chassis protocol adjacency (MX Series Virtual Chassis) . . . . . . . . . 311
show virtual-chassis protocol database (MX Series Virtual Chassis) . . . . . . . . . 315
show virtual-chassis protocol interface (MX Series Virtual Chassis) . . . . . . . . . . 321
show virtual-chassis protocol route (MX Series Virtual Chassis) . . . . . . . . . . . . 324
show virtual-chassis protocol statistics (MX Series Virtual Chassis) . . . . . . . . . 327
show virtual-chassis status (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . . 330
show virtual-chassis vc-port (MX Series Virtual Chassis) . . . . . . . . . . . . . . . . . . 332
Copyright © 2017, Juniper Networks, Inc.
vii
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
viii
Copyright © 2017, Juniper Networks, Inc.
List of Figures
Chapter 2
Understanding How a Virtual Chassis Works . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 1: Sample Topology for MX Series Virtual Chassis . . . . . . . . . . . . . . . . . . . . 24
Chapter 3
Configuring a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 2: Sample Topology for a Virtual Chassis with Two MX Series Routers . . . 76
Figure 3: Sample Topology for a Virtual Chassis with Two MX Series Routers . . . 101
Figure 4: Sample Topology for a Virtual Chassis with Two MX Series Routers . . . 113
Chapter 8
Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D
Universal Edge Routers by Rebooting the Routing Engines . . . . . . . . . . . . 165
Figure 5: Sample Topology for a Virtual Chassis with Two MX Series Routers . . 166
Copyright © 2017, Juniper Networks, Inc.
ix
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
x
Copyright © 2017, Juniper Networks, Inc.
List of Tables
About the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Table 1: Notice Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Table 2: Text and Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
Chapter 1
Understanding How Virtual Chassis Provides Interchassis
Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 3: MX Series Virtual Chassis Supported Member Router Combinations . . . . 21
Chapter 2
Understanding How a Virtual Chassis Works . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 4: Slot Count and Slot Numbering for MX Series Virtual Chassis Supported
Member Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 5: Global Roles and Local Roles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 6: Virtual Chassis Role Transitions During Global Switchover . . . . . . . . . . . 35
Table 7: Virtual Chassis Role Transitions During Local Switchover Performed
from VC-Mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 8: Virtual Chassis Role Transitions During Local Switchover Performed
from VC-Bm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 9: Effect of Split Detection on Common Virtual Chassis Failure
Scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 10: Comparison of Heartbeat Connection Configuration Tasks for Member
Routers in Same Subnet and Member Routers in Different Subnets . . . . . . . 44
Table 11: Effect of Heartbeat Connection on Common Virtual Chassis Failure
Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 12: Comparison of Heartbeat Connection and Split Detection for Virtual
Chassis Failure Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Chapter 3
Configuring a Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 14: Components of the Sample MX Series Virtual Chassis . . . . . . . . . . . . . . 77
Table 15: Virtual Chassis Global Role Transitions Before and After Mastership
Switchover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Table 16: Components of the Sample MX Series Virtual Chassis . . . . . . . . . . . . . 101
Table 17: Virtual Chassis Role Transitions Before and After Local Routing Engine
Switchover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Table 18: Components of the Sample MX Series Virtual Chassis . . . . . . . . . . . . . 113
Chapter 6
Configuring Class of Service for Virtual Chassis Ports . . . . . . . . . . . . . . . . . 145
Table 19: Sample CoS Scheduler Hierarchy for Virtual Chassis Ports . . . . . . . . . . 151
Chapter 8
Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D
Universal Edge Routers by Rebooting the Routing Engines . . . . . . . . . . . . 165
Copyright © 2017, Juniper Networks, Inc.
xi
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 20: Components of the Sample MX Series Virtual Chassis . . . . . . . . . . . . 167
Chapter 9
Upgrading Junos OS in an MX Series Virtual Chassis by Performing a
Unified In-Service Software Upgrade (ISSU) . . . . . . . . . . . . . . . . . . . . . . . . . 171
Table 21: Virtual Chassis Role Transitions After Unified ISSU . . . . . . . . . . . . . . . . 173
Chapter 10
Monitoring an MX Series Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Table 22: jnxFruSlot Numbers and Corresponding Slot Numbers in an MX Series
or EX9200 Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Table 23: Components of the Sample MX Series Virtual Chassis with Member
Routers in Same Subnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Table 24: Heartbeat Cross-Connections for Member Routers in Different
Subnets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Table 25: Components of the Sample MX Series Virtual Chassis with Member
Routers in Different Subnets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Chapter 11
Tracing Virtual Chassis Operations for Troubleshooting Purposes . . . . . . 223
Table 26: Tracing Flags for Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Chapter 13
Operational Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Table 27: clear virtual-chassis heartbeat Output Fields . . . . . . . . . . . . . . . . . . . . 253
Table 28: show chassis network services Output Fields . . . . . . . . . . . . . . . . . . . 280
Table 29: show interfaces vcp Output Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Table 30: show services accounting status Output Fields . . . . . . . . . . . . . . . . . . 300
Table 31: show virtual-chassis active-topology Output Fields . . . . . . . . . . . . . . . 303
Table 32: show virtual-chassis device-topology Output Fields . . . . . . . . . . . . . . 305
Table 33: show virtual-chassis heartbeat Output Fields . . . . . . . . . . . . . . . . . . . 309
Table 34: show virtual-chassis protocol adjacency Output Fields . . . . . . . . . . . . 312
Table 35: show virtual-chassis protocol database Output Fields . . . . . . . . . . . . . 316
Table 36: show virtual-chassis protocol interface Output Fields . . . . . . . . . . . . . 322
Table 37: show virtual-chassis protocol route Output Fields . . . . . . . . . . . . . . . . 324
Table 38: show virtual-chassis protocol statistics Output Fields . . . . . . . . . . . . . 327
Table 39: show virtual-chassis status Output Fields . . . . . . . . . . . . . . . . . . . . . . 330
Table 40: show virtual-chassis vc-port Output Fields . . . . . . . . . . . . . . . . . . . . . 332
xii
Copyright © 2017, Juniper Networks, Inc.
About the Documentation
•
Documentation and Release Notes on page xiii
•
Supported Platforms on page xiii
•
Using the Examples in This Manual on page xiii
•
Documentation Conventions on page xv
•
Documentation Feedback on page xvii
•
Requesting Technical Support on page xvii
Documentation and Release Notes
®
To obtain the most current version of all Juniper Networks technical documentation,
see the product documentation page on the Juniper Networks website at
http://www.juniper.net/techpubs/.
If the information in the latest release notes differs from the information in the
documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject
matter experts. These books go beyond the technical documentation to explore the
nuances of network architecture, deployment, and administration. The current list can
be viewed at http://www.juniper.net/books.
Supported Platforms
For the features described in this document, the following platforms are supported:
•
MX Series
Using the Examples in This Manual
If you want to use the examples in this manual, you can use the load merge or the load
merge relative command. These commands cause the software to merge the incoming
configuration into the current candidate configuration. The example does not become
active until you commit the candidate configuration.
If the example configuration contains the top level of the hierarchy (or multiple
hierarchies), the example is a full example. In this case, use the load merge command.
Copyright © 2017, Juniper Networks, Inc.
xiii
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
If the example configuration does not start at the top level of the hierarchy, the example
is a snippet. In this case, use the load merge relative command. These procedures are
described in the following sections.
Merging a Full Example
To merge a full example, follow these steps:
1.
From the HTML or PDF version of the manual, copy a configuration example into a
text file, save the file with a name, and copy the file to a directory on your routing
platform.
For example, copy the following configuration to a file and name the file ex-script.conf.
Copy the ex-script.conf file to the /var/tmp directory on your routing platform.
system {
scripts {
commit {
file ex-script.xsl;
}
}
}
interfaces {
fxp0 {
disable;
unit 0 {
family inet {
address 10.0.0.1/24;
}
}
}
}
2. Merge the contents of the file into your routing platform configuration by issuing the
load merge configuration mode command:
[edit]
user@host# load merge /var/tmp/ex-script.conf
load complete
Merging a Snippet
To merge a snippet, follow these steps:
1.
From the HTML or PDF version of the manual, copy a configuration snippet into a text
file, save the file with a name, and copy the file to a directory on your routing platform.
For example, copy the following snippet to a file and name the file
ex-script-snippet.conf. Copy the ex-script-snippet.conf file to the /var/tmp directory
on your routing platform.
commit {
file ex-script-snippet.xsl; }
xiv
Copyright © 2017, Juniper Networks, Inc.
About the Documentation
2. Move to the hierarchy level that is relevant for this snippet by issuing the following
configuration mode command:
[edit]
user@host# edit system scripts
[edit system scripts]
3. Merge the contents of the file into your routing platform configuration by issuing the
load merge relative configuration mode command:
[edit system scripts]
user@host# load merge relative /var/tmp/ex-script-snippet.conf
load complete
For more information about the load command, see CLI Explorer.
Documentation Conventions
Table 1 on page xv defines notice icons used in this guide.
Table 1: Notice Icons
Icon
Meaning
Description
Informational note
Indicates important features or instructions.
Caution
Indicates a situation that might result in loss of data or hardware damage.
Warning
Alerts you to the risk of personal injury or death.
Laser warning
Alerts you to the risk of personal injury from a laser.
Tip
Indicates helpful information.
Best practice
Alerts you to a recommended use or implementation.
Table 2 on page xvi defines the text and syntax conventions used in this guide.
Copyright © 2017, Juniper Networks, Inc.
xv
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 2: Text and Syntax Conventions
Convention
Description
Examples
Bold text like this
Represents text that you type.
To enter configuration mode, type the
configure command:
user@host> configure
Fixed-width text like this
Italic text like this
Italic text like this
Represents output that appears on the
terminal screen.
user@host> show chassis alarms
•
Introduces or emphasizes important
new terms.
•
•
Identifies guide names.
A policy term is a named structure
that defines match conditions and
actions.
•
Identifies RFC and Internet draft titles.
•
Junos OS CLI User Guide
•
RFC 1997, BGP Communities Attribute
No alarms currently active
Represents variables (options for which
you substitute a value) in commands or
configuration statements.
Configure the machine’s domain name:
Represents names of configuration
statements, commands, files, and
directories; configuration hierarchy levels;
or labels on routing platform
components.
•
To configure a stub area, include the
stub statement at the [edit protocols
ospf area area-id] hierarchy level.
•
The console port is labeled CONSOLE.
< > (angle brackets)
Encloses optional keywords or variables.
stub <default-metric metric>;
| (pipe symbol)
Indicates a choice between the mutually
exclusive keywords or variables on either
side of the symbol. The set of choices is
often enclosed in parentheses for clarity.
broadcast | multicast
# (pound sign)
Indicates a comment specified on the
same line as the configuration statement
to which it applies.
rsvp { # Required for dynamic MPLS only
[ ] (square brackets)
Encloses a variable for which you can
substitute one or more values.
community name members [
community-ids ]
Indention and braces ( { } )
Identifies a level in the configuration
hierarchy.
; (semicolon)
Identifies a leaf statement at a
configuration hierarchy level.
Text like this
[edit]
root@# set system domain-name
domain-name
(string1 | string2 | string3)
[edit]
routing-options {
static {
route default {
nexthop address;
retain;
}
}
}
GUI Conventions
xvi
Copyright © 2017, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions (continued)
Convention
Description
Examples
Bold text like this
Represents graphical user interface (GUI)
items you click or select.
•
In the Logical Interfaces box, select
All Interfaces.
•
To cancel the configuration, click
Cancel.
> (bold right angle bracket)
Separates levels in a hierarchy of menu
selections.
In the configuration editor hierarchy,
select Protocols>Ospf.
Documentation Feedback
We encourage you to provide feedback, comments, and suggestions so that we can
improve the documentation. You can provide feedback by using either of the following
methods:
•
Online feedback rating system—On any page of the Juniper Networks TechLibrary site
at http://www.juniper.net/techpubs/index.html, simply click the stars to rate the content,
and use the pop-up form to provide us with information about your experience.
Alternately, you can use the online feedback form at
http://www.juniper.net/techpubs/feedback/.
•
E-mail—Send your comments to techpubs-comments@juniper.net. Include the document
or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or Partner Support Service
support contract, or are covered under warranty, and need post-sales technical support,
you can access our tools and resources online or open a case with JTAC.
•
JTAC policies—For a complete understanding of our JTAC procedures and policies,
review the JTAC User Guide located at
http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf.
•
Product warranties—For product warranty information, visit
http://www.juniper.net/support/warranty/.
•
JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online
self-service portal called the Customer Support Center (CSC) that provides you with the
following features:
Copyright © 2017, Juniper Networks, Inc.
xvii
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
Find CSC offerings: http://www.juniper.net/customers/support/
•
Search for known bugs: http://www2.juniper.net/kb/
•
Find product documentation: http://www.juniper.net/techpubs/
•
Find solutions and answer questions using our Knowledge Base: http://kb.juniper.net/
•
Download the latest versions of software and review release notes:
http://www.juniper.net/customers/csc/software/
•
Search technical bulletins for relevant hardware and software notifications:
http://kb.juniper.net/InfoCenter/
•
Join and participate in the Juniper Networks Community Forum:
http://www.juniper.net/company/communities/
•
Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/
Opening a Case with JTAC
You can open a case with JTAC on the Web or by telephone.
•
Use the Case Management tool in the CSC at http://www.juniper.net/cm/.
•
Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
For international or direct-dial options in countries without toll-free numbers, see
http://www.juniper.net/support/requesting-support.html.
xviii
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 1
Understanding How Virtual Chassis
Provides Interchassis Redundancy
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
Interchassis Redundancy and Virtual Chassis Overview
As more high-priority voice and video traffic is carried on the network, interchassis
redundancy has become a baseline requirement for providing stateful redundancy on
broadband subscriber management equipment such as broadband services routers,
broadband network gateways, and broadband remote access servers. To provide a
stateful interchassis redundancy solution for MX Series 3D Universal Edge Routers, you
can configure a Virtual Chassis.
This topic provides an overview of interchassis redundancy and the Virtual Chassis, and
explains the benefits of configuring a Virtual Chassis on supported MX Series routers.
•
Interchassis Redundancy Overview on page 19
•
Virtual Chassis Overview on page 20
•
Benefits of Configuring a Virtual Chassis on page 20
•
Supported Routing Platforms for MX Series Virtual Chassis on page 21
Interchassis Redundancy Overview
Traditionally, redundancy in broadband edge equipment has used an intrachassis
approach, which focuses on providing redundancy within a single system. However, a
single-system redundancy mechanism no longer provides the degree of high availability
required by service providers who must carry mission-critical voice and video traffic on
their network. Consequently, service providers are requiring interchassis redundancy
solutions that can span multiple systems that are colocated or geographically dispersed.
Interchassis redundancy is a high availability feature that prevents network outages and
protects routers against access link failures, uplink failures, and wholesale chassis failures
without visibly disrupting the attached subscribers or increasing the network management
burden for service providers. Network outages can cause service providers to lose revenues
and require them to register formal reports with government agencies. A robust
interchassis redundancy implementation enables service providers to fulfill strict
Copyright © 2017, Juniper Networks, Inc.
19
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
service-level agreements (SLAs) and avoid unplanned network outages to better meet
the needs of their customers.
Virtual Chassis Overview
One approach to providing interchassis redundancy is the Virtual Chassis model. In general
terms, a Virtual Chassis configuration enables a collection of member routers to function
as a single virtual router, and extends the features available on a single router to the
member routers in the Virtual Chassis. The interconnected member routers in a Virtual
Chassis are managed as a single network element that appears to the network
administrator as a single chassis with additional line card slots, and to the access network
as a single system.
To provide a stateful interchassis redundancy solution for MX Series 3D Universal Edge
Routers, you can configure a Virtual Chassis. An MX Series Virtual Chassis interconnects
two MX Series routers into a logical system that you can manage as a single network
element. The member routers in a Virtual Chassis are designated as the Virtual Chassis
master router (also known as the protocol master) and the Virtual Chassis backup router
(also known as the protocol backup). The member routers are interconnected by means
of dedicated Virtual Chassis ports that you configure on Modular Port
Concentrator/Modular Interface Card (MPC/MIC) interfaces.
An MX Series Virtual Chassis is managed by the Virtual Chassis Control Protocol (VCCP),
which is a dedicated control protocol based on IS-IS. VCCP runs on the Virtual Chassis
port interfaces and is responsible for building the Virtual Chassis topology, electing the
Virtual Chassis master router, and establishing the interchassis routing table to route
traffic within the Virtual Chassis.
NOTE: MX Series Virtual Chassis does not support Ethernet OAM, distributed
inline connectivity fault management, Ethernet frame delay measurement,
loss measurement, synthetic loss measurement, and Ethernet alarm indication
signal (ETH-AIS).
Benefits of Configuring a Virtual Chassis
Configuring a Virtual Chassis for MX Series routers provides the following benefits:
20
•
Simplifies network management of two routers that are either colocated or
geographically dispersed across a Layer 2 point-to-point network.
•
Provides resiliency against network outages and protects member routers against
access link failures, uplink failures, and chassis failures without visibly disrupting
attached subscribers or increasing the network management burden for service
providers.
•
Extends the high availability capabilities of applications such as graceful Routing Engine
switchover (GRES) and nonstop active routing (NSR) beyond a single MX Series router
to both member routers in the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
Chapter 1: Understanding How Virtual Chassis Provides Interchassis Redundancy
•
Enables service providers to fulfill strict service level agreements (SLAs) and avoid
unplanned network outages to better meet their customers’ needs.
•
Provides the ability to scale bandwidth and service capacity as more high-priority voice
and video traffic is carried on the network.
Supported Routing Platforms for MX Series Virtual Chassis
You can configure a Virtual Chassis on the following MX Series 3D Universal Edge Routers
with MPC/MIC interfaces:
•
MX240 3D Universal Edge Router
•
MX480 3D Universal Edge Router
•
MX960 3D Universal Edge Router
•
MX2010 3D Universal Edge Router
•
MX2020 3D Universal Edge Router
NOTE: Platform support depends on the Junos OS release in your installation.
Graceful Routing Engine switchover (GRES) and nonstop active routing (NSR) must be
enabled on both member routers in the Virtual Chassis.
Supported Member Router Combinations
A two-member MX Series Virtual Chassis supports the member router combinations
marked as Yes in Table 3 on page 21.
Table 3: MX Series Virtual Chassis Supported Member Router
Combinations
Member Router
Type
MX240
MX480
MX960
MX2010
MX2020
MX240
Yes
Yes
Yes
No
No
MX480
Yes
Yes
Yes
No
No
MX960
Yes
Yes
Yes
Yes
Yes
MX2010
No
No
Yes
Yes
Yes
MX2020
No
No
Yes
Yes
Yes
Routing Engine Requirements
Each member router in the Virtual Chassis must have dual Routing Engines installed, and
all four Routing Engines in the Virtual Chassis must be the same model. For example,
you cannot configure a Virtual Chassis if one member router has two RE-S-2000 Routing
Copyright © 2017, Juniper Networks, Inc.
21
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Engines installed and the other member router has two RE-S-1800 Routing Engines
installed.
NOTE: For an MX Series Virtual Chassis configuration that includes an
MX2020 router, all four Routing Engines in the Virtual Chassis must have at
least 16 gigabytes of memory.
Related
Documentation
22
•
Virtual Chassis Components Overview on page 24
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 2
Understanding How a Virtual Chassis
Works
•
Virtual Chassis Components Overview on page 24
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Mastership Election in a Virtual Chassis on page 32
•
Switchover Behavior in an MX Series Virtual Chassis on page 34
•
Split Detection Behavior in a Virtual Chassis on page 38
•
Virtual Chassis Heartbeat Connection Overview on page 41
•
Command Forwarding in a Virtual Chassis on page 47
Copyright © 2017, Juniper Networks, Inc.
23
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Virtual Chassis Components Overview
A Virtual Chassis configuration for MX Series 3D Universal Edge Routers interconnects
two MX Series routers into a logical system that you can manage as a single network
element.Figure 1 on page 24 illustrates a typical topology for a two-member MX Series
Virtual Chassis.
Figure 1: Sample Topology for MX Series Virtual Chassis
This overview describes the basic hardware and software components of the Virtual
Chassis configuration illustrated in Figure 1 on page 24, and covers the following topics:
•
Virtual Chassis Master Router on page 24
•
Virtual Chassis Backup Router on page 25
•
Virtual Chassis Line-Card Router on page 25
•
Virtual Chassis Ports on page 26
•
Virtual Chassis Port Trunks on page 27
•
Slot Numbering in the Virtual Chassis on page 27
•
Configuration of Chassis Properties for MPCs in the Virtual Chassis on page 28
•
Virtual Chassis Control Protocol on page 29
•
Member IDs, Roles, and Serial Numbers on page 29
Virtual Chassis Master Router
One of the two member routers in the Virtual Chassis becomes the master router, also
known as the protocol master. The Virtual Chassis master router maintains the global
configuration and state information for both member routers, and runs the chassis
management processes. The master Routing Engine that resides in the Virtual Chassis
master router becomes the global master for the Virtual Chassis.
24
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
Specifically, the master Routing Engine that resides in the Virtual Chassis master router
performs the following functions in a Virtual Chassis:
•
Manages both the master and backup member routers
•
Runs the chassis management processes and control protocols
•
Receives and processes all incoming and exception path traffic destined for the Virtual
Chassis
•
Propagates the Virtual Chassis configuration (including member IDs, roles, and
configuration group definitions and applications) to the members of the Virtual Chassis
The first member of the Virtual Chassis becomes the initial master router by default.
After the Virtual Chassis is formed with both member routers, the Virtual Chassis Control
Protocol (VCCP) software runs a mastership election algorithm to elect the master router
for the Virtual Chassis configuration.
NOTE: You cannot configure mastership election for an MX Series Virtual
Chassis in the current release.
Virtual Chassis Backup Router
The member router in the Virtual Chassis that is not designated as the master router
becomes the backup router, also known as the protocol backup. The Virtual Chassis
backup router takes over mastership of the Virtual Chassis if the master router is
unavailable, and synchronizes routing and state information with the master router. The
master Routing Engine that resides in the Virtual Chassis backup router becomes the
global backup for the Virtual Chassis.
Specifically, the master Routing Engine that resides in the Virtual Chassis backup router
performs the following functions in a Virtual Chassis:
•
If the master router fails or is unavailable, takes over mastership of the Virtual Chassis
in order to preserve routing information and maintain network connectivity without
disruption
•
Synchronizes routing and application state, including routing tables and subscriber
state information, with the master Routing Engine that resides in the Virtual Chassis
master router
•
Relays chassis control information, such as line card presence and alarms, to the master
router
Virtual Chassis Line-Card Router
NOTE: The line-card role is not supported in the preprovisioned configuration
for a two-member MX Series Virtual Chassis. In this release, the line-card role
applies only in the context of split detection behavior.
Copyright © 2017, Juniper Networks, Inc.
25
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
A member router functioning in the line-card role runs only a minimal set of chassis
management processes required to relay chassis control information, such as line card
presence and alarms, to the Virtual Chassis master router.
You cannot explicitly configure a member router with the line-card role in the current
release. However, if the backup router fails in a two-member Virtual Chassis configuration
and split detection is enabled (the default behavior), the master router takes a line-card
role, and line cards (FPCs) that do not host Virtual Chassis ports go offline. This state
effectively isolates the master router and removes it from the Virtual Chassis until
connectivity is restored. As a result, routing is halted and the Virtual Chassis configuration
is disabled.
Virtual Chassis Ports
Virtual Chassis ports are special Ethernet interfaces that form a point-to-point connection
between the member routers in a Virtual Chassis. When you create a Virtual Chassis, you
must configure the Virtual Chassis ports on Modular Port Concentrator/Modular Interface
Card (MPC/MIC) interfaces. After you configure a Virtual Chassis port, it is renamed
vcp-slot/pic/port (for example, vcp-2/2/0), and the line card associated with that port
comes online. For example, the sample Virtual Chassis topology shown in
Figure 1 on page 24 has a total of four Virtual Chassis ports (represented by the blue
dots), two on each of the two member routers.
After a Virtual Chassis port is configured, it is dedicated to the task of interconnecting
member routers, and is no longer available for configuration as a standard network port.
To restore this port to the global configuration and make it available to function as a
standard network port, you must delete the Virtual Chassis port from the Virtual Chassis
configuration.
NOTE: The Junos OS software enables you to preconfigure ports that are
currently unavailable for use. Although a Virtual Chassis port is unavailable
for use as a standard network port, you can configure this port as a standard
network port even after you configure it as a Virtual Chassis port. However,
the router does not apply the configuration until you delete the Virtual Chassis
port from the Virtual Chassis configuration.
You can configure a Virtual Chassis port on either a 1-Gigabit Ethernet (ge) interface, a
10-Gigabit Ethernet (xe) interface, a 40-Gigabit Ethernet (et) interface, or a 100-Gigabit
Ethernet (et) interface. 40-Gigabit and 100-Gigabit Virtual Chassis ports can only be
configured on MPC3, MPC4, or later line cards. (Interface support depends on the Junos
OS release in your installation.) You cannot configure a combination of 1-Gigabit Ethernet
Virtual Chassis ports and 10-Gigabit Ethernet Virtual Chassis ports in the same Virtual
Chassis. We recommend that you configure Virtual Chassis ports only on 10-Gigabit
Ethernet interfaces. In addition, to minimize network disruption in the event of a router
or link failure, configure redundant Virtual Chassis ports that reside on different line cards
in each member router.
Virtual Chassis port interfaces carry both VCCP packets and internal control and data
traffic. Because the internal control traffic is neither encrypted nor authenticated, make
26
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
sure the Virtual Chassis port interfaces are properly secured to prevent malicious
third-party attacks on the data.
Virtual Chassis ports use a default class of service (CoS) configuration that applies
equally to all Virtual Chassis port interfaces configured in a Virtual Chassis. Optionally,
you can create a customized CoS traffic-control profile and apply it to all Virtual Chassis
port interfaces. For example, you might want to create a nondefault traffic-control profile
that allocates more than the default 5 percent of the Virtual Chassis port bandwidth to
control traffic, or that assigns different priorities and excess rates to different forwarding
classes.
Virtual Chassis Port Trunks
If two or more Virtual Chassis ports of the same type and speed are configured between
the same two member routers in an MX Series Virtual Chassis, the Virtual Chassis Control
Protocol (VCCP) bundles these Virtual Chassis port interfaces into a trunk, reduces the
routing cost accordingly, and performs traffic load balancing across all of the Virtual
Chassis port interfaces (also referred to as Virtual Chassis port links) in the trunk.
A Virtual Chassis port trunk must include only Virtual Chassis ports of the same type and
speed. For example, a Virtual Chassis port trunk can include either all 10-Gigabit Ethernet
(xe media type) Virtual Chassis ports or all 1-Gigabit Ethernet (ge media type) Virtual
Chassis ports. An MX Series Virtual Chassis does not support a combination of 1-Gigabit
Ethernet Virtual Chassis ports and 10-Gigabit Ethernet Virtual Chassis ports in the same
Virtual Chassis port trunk.
The router uses the following formula to determine the cost metric of a Virtual Chassis
port link in a Virtual Chassis port trunk:
Cost = (300 * 1,000,000,000) / port-speed
where port-speed is the aggegate speed, in bits per second, of the Virtual Chassis port.
For example, a 10-Gigabit Ethernet Virtual Chassis port link has a cost metric of 30 (300
* 1,000,000,000 / 10,000,000,000). A 1-Gigabit Ethernet Virtual Chassis port link has
a cost metric of 300 (300 * 1,000,000,000 / 1,000,000,000). Virtual Chassis port links
with a lower cost metric are preferred over those with a higher cost metric.
An MX Series Virtual Chassis supports up to 16 Virtual Chassis ports per trunk.
Slot Numbering in the Virtual Chassis
After you configure the member ID and, optionally, slot count for each router that you
want to add to an MX Series Virtual Chassis, the Routing Engines in that chassis reboot
and the slots for line cards (FPCs) are renumbered. The FPC slot numbering used for
each member router is based on the slot count and offsets used in the Virtual Chassis
instead of the physical slot numbers where the line card is actually installed.
Table 4 on page 28 shows the valid slot count values for each supported member router
type, and the slot numbering used for member 0 and member 1 when the specified slot
count value is configured, either explicitly or by default.
Copyright © 2017, Juniper Networks, Inc.
27
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 4: Slot Count and Slot Numbering for MX Series Virtual Chassis Supported Member
Routers
Member Router Type
Slot Count
FPC Slot Numbers on member 0
FPC Slot Numbers on member 1
MX240
N/A
0 through 11 (no offset)
12 through 23 (offset=12)
MX480
N/A
0 through 11 (no offset)
12 through 23 (offset=12)
MX960
12 (default)
0 through 11 (no offset)
12 through 23 (offset=12)
MX960
20
0 through 19 (no offset)
20 through 39 (offset=20)
MX2010
12 (default)
0 through 11 (no offset)
12 through 23 (offset=12)
MX2010
20
0 through 19 (no offset)
20 through 39 (offset=20)
MX2020
20 (default)
0 through 19 (no offset)
20 through 39 (offset=20)
For example, assume that in your Virtual Chassis configuration, member 0 is an MX960
router and member 1 is an MX2010 router, with the default slot count (12) in effect on
both routers. In this topology, a 10-Gigabit Ethernet interface that appears as xe-14/2/2
(FPC slot 14, PIC slot 2, port 2) in the show interfaces command output is actually physical
interface xe-2/2/2 (FPC slot 2, PIC slot 2, port 2) on member 1 after deducting the offset
of 12 for member 1.
Building on this example, assume that you replace member 1 with an MX2020 member
router, resulting in a Virtual Chassis with an MX960 router configured as member 0 and
an MX2020 router configured as member 1. To ensure that a Virtual Chassis consisting
of an MX2020 router and either an MX960 router or MX2010 router forms properly, you
must explicitly set the slot count for the MX960 router or MX2010 router to 20 to match
the slot count of the MX2020 router. When the FPC slots are renumbered in this topology,
physical interface xe-2/2/2 on member 1 becomes xe-22/2/2 on member 1 after adding
the offset of 20 for member 1. Similarly, the show interfaces command displays xe-22/2/2
as the interface name.
NOTE: Slot renumbering does not affect the names of Virtual Chassis ports.
The Virtual Chassis port name, in the format vcp-slot/pic/port, is derived from
the physical slot number where the port is configured. For example, vcp-3/2/0
is configured on FPC physical slot 3, PIC slot 2, port 0.
Configuration of Chassis Properties for MPCs in the Virtual Chassis
When you configure chassis properties for MPCs installed in a member router in an
MX Series Virtual Chassis, keep the following points in mind:
•
28
Statements included at the [edit chassis member member-id fpc slot slot-number]
hierarchy level apply to the MPC (FPC) in the specified slot number only on the specified
member router in the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
For example, if you issue the set chassis member 0 fpc slot 1 power off statement, only
the MPC installed in slot 1 of member ID 0 in the Virtual Chassis is powered off.
•
Statements included at the [edit chassis fpc slot slot-number] hierarchy level should
be relocated to the [edit chassis member member-id fpc slot slot-number] hierarchy
level to avoid errors.
BEST PRACTICE: To ensure that the statement you use to configure MPC
chassis properties in a Virtual Chassis applies to the intended member router
and MPC, always include the member member-ID option before the fpc
keyword, where member-id is 0 or 1 for a two-member MX Series Virtual
Chassis.
Virtual Chassis Control Protocol
An MX Series Virtual Chassis is managed by the Virtual Chassis Control Protocol (VCCP),
which is a dedicated control protocol based on IS-IS. VCCP runs on the Virtual Chassis
port interfaces and performs the following functions in the Virtual Chassis:
•
Discovers and builds the Virtual Chassis topology
•
Runs the mastership election algorithm to determine the Virtual Chassis master router
•
Establishes the interchassis routing table to route traffic within the Virtual Chassis
Like IS-IS, VCCP exchanges link-state PDUs for each member router to construct a
shortest path first (SPF) topology and to determine each member router’s role (master
or backup) in the Virtual Chassis. Because VCCP supports only point-to-point connections,
no more than two member routers can be connected on any given Virtual Chassis port
interface.
Member IDs, Roles, and Serial Numbers
To configure an MX Series Virtual Chassis, you must create a preprovisioned configuration
that provides the following required information for each member router:
•
Member ID—A numeric value (0 or 1) that identifies the member router in a Virtual
Chassis configuration.
•
Role—The role to be performed by each member router in the Virtual Chassis. In a
two-member MX Series Virtual Chassis, you must assign both member routers the
routing-engine role, which enables either router to function as the master router or
backup router of the Virtual Chassis.
•
Serial number—The chassis serial number of each member router in the Virtual Chassis.
To obtain the router’s serial number, find the label affixed to the side of the MX Series
chassis, or issue the show chassis hardware command on the router to display the serial
number in the command output.
The preprovisioned configuration permanently associates the member ID and role with
the member router’s chassis serial number. When a new member router joins the Virtual
Copyright © 2017, Juniper Networks, Inc.
29
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Chassis, the VCCP software compares the router’s serial number against the values
specified in the preprovisioned configuration. If the serial number of a joining router does
not match any of the configured serial numbers, the VCCP software prevents that router
from becoming a member of the Virtual Chassis.
Related
Documentation
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Guidelines for Configuring Virtual Chassis Ports on page 134
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Split Detection Behavior in a Virtual Chassis on page 38
•
Virtual Chassis Slot Number Mapping for Use with SNMP on page 194
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Global Roles and Local Roles in a Virtual Chassis
In a Virtual Chassis configuration for MX Series 3D Universal Edge Routers or EX9200
switches, each of the two member devices and each of the two Routing Engines in each
member device has a distinct role. A global role defines the function of each member
device in the Virtual Chassis, and applies globally across the entire Virtual Chassis. A local
role defines the function of each Routing Engine in the member device, and applies locally
only to that member device.
Global roles change when you switch the Virtual Chassis mastership, and both global
roles and local roles change when you switch the Routing Engine mastership in one of
the member devices. In addition, the line-card global role, though not supported in a
preprovisioned configuration for a two-member MX Series or EX9200 Virtual Chassis,
applies in the context of split detection behavior.
This topic describes the global roles and local roles in a MX Series or EX9200 Virtual
Chassis so you can better understand how the Virtual Chassis behaves during a global
mastership switch, a local Routing Engine switchover, or when split detection is enabled.
•
Role Name Format on page 30
•
Global Role and Local Role Descriptions on page 31
Role Name Format
The global and local role names in an MX Series or EX9200 Virtual Chassis use the
following format:
VC-GlobalRole<LocalRole>
where:
•
GlobalRole applies to the global function of the member device for the entire Virtual
Chassis, and can be one of the following:
•
30
M—Virtual Chassis master device, also referred to as the protocol master.
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
•
B—Virtual Chassis backup device, also referred to as the protocol backup.
•
L—Virtual Chassis line-card device. The line-card role is not supported in the
preprovisioned configuration for a two-member Virtual Chassis. The line-card role
applies only in the context of split detection behavior.
•
LocalRole (optional) applies to the function of the Routing Engine in the local member
device, and can be one of the following:
•
m—Master Routing Engine
•
s—Standby Routing Engine
Global Role and Local Role Descriptions
Table 5 on page 31 describes the global roles and local roles in an MX Series or EX9200
Virtual Chassis.
Table 5: Global Roles and Local Roles
Virtual Chassis Role
Type of Role
Description
VC-M
Global
Master device for the Virtual Chassis
VC-B
Global
Backup device for the Virtual Chassis
VC-L
Global
Line-card device for the Virtual Chassis
NOTE: The line-card role is not supported in the
preprovisioned configuration for a two-member
MX Series or EX9200 Virtual Chassis. The
line-card role applies only in the context of split
detection behavior.
VC-Mm
Local
Master Routing Engine in the Virtual Chassis
master device
VC-Ms
Local
Standby Routing Engine in the Virtual Chassis
master device
VC-Bm
Local
Master Routing Engine in the Virtual Chassis
backup device
VC-Bs
Local
Standby Routing Engine in the Virtual Chassis
backup device
VC-Lm
Local
Master Routing Engine in the Virtual Chassis
line-card device
NOTE: The line-card role is not supported in the
preprovisioned configuration for a two-member
MX Series or EX9200 Virtual Chassis. The
line-card role applies only in the context of split
detection behavior.
Copyright © 2017, Juniper Networks, Inc.
31
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 5: Global Roles and Local Roles (continued)
Virtual Chassis Role
Type of Role
Description
VC-Ls
Local
Standby Routing Engine in the Virtual Chassis
line-card device
NOTE: The line-card role is not supported in the
preprovisioned configuration for a two-member
MX Series or EX9200 Virtual Chassis. The
line-card role applies only in the context of split
detection behavior.
Related
Documentation
•
Virtual Chassis Components Overview on page 24
•
Understanding EX9200 Virtual Chassis
•
Mastership Election in a Virtual Chassis on page 32
•
Switching the Global Master and Backup Roles in a Virtual Chassis Configuration on
page 95
•
Disabling Split Detection in a Virtual Chassis Configuration on page 98
Mastership Election in a Virtual Chassis
In a two-member MX Series or EX9200 Virtual Chassis, either member device can be
elected as the master device (also known as the protocol master, or VC-M) of the Virtual
Chassis. The first member device to join the Virtual Chassis becomes the initial master
device by default. After the Virtual Chassis is formed with both member devices, the
Virtual Chassis Control Protocol (VCCP) software runs a mastership election algorithm
to elect the master device for the Virtual Chassis configuration.
If the master device in a Virtual Chassis fails, the backup device (also known as the
protocol backup, or VC-B) takes over mastership of the Virtual Chassis. You can also
switch the global roles of the master device and backup device in a Virtual Chassis by
issuing the request virtual-chassis routing-engine master switch command.
NOTE: You cannot configure mastership election for an MX Series or EX9200
Virtual Chassis in the current release.
The VCCP software uses the following algorithm to elect the master device for an EX9200
or MX Series Virtual Chassis:
1.
Choose the member device that has the highest value for the internal mastership
election flag.
The mastership election algorithm uses an internal flag that keeps track of the member
state for the purpose of electing the Virtual Chassis master device. In most cases,
VCCP elects the member device with the higher flag value over the member device
with the lower flag value as the protocol master.
32
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
To display the mastership election flag value, issue the show virtual-chassis protocol
database extensive command. The flag value used for mastership election appears
in the TLVs field of the command output, as shown in the following example:
{master:member1-re0}
user@host> show virtual-chassis protocol database member 0 extensive
...
TLVs:
Node Info: Member ID: 1, VC ID: 5a6a.e747.8511, Flags: 3, Priority: 129
System ID: 001d.b510.0800, Device ID: 1
...
2. Choose the member device with the highest mastership priority value.
The mastership priority value is assigned to the member device by the VCCP software,
and is not configurable in the current release. The mastership priority value can be
one of the following:
•
129—The routing-engine role is assigned to the member device.
•
128—No role is assigned to the member device.
•
0—The line-card role is assigned to the member device (not supported in the current
release).
To display the mastership priority value for the member devices in the Virtual Chassis,
issue the show virtual-chassis status command.
3. Choose the member device that is active in the Virtual Chassis.
4. Choose the member device that belongs to the Virtual Chassis with the largest number
of members.
NOTE: This criterion is not used in the current release because all EX9200
and MX Series Virtual Chassis configurations have two member devices.
5. Choose the member device that is the accepted (elected) protocol master of the
Virtual Chassis.
6. Choose the member device that is the current protocol master (VC-M) of the same
Virtual Chassis.
7. Choose the member device that is the current protocol backup (VC-B) of the same
Virtual Chassis.
8. Choose the member device that has been part of the Virtual Chassis configuration
for the longest period of time.
9. Choose the member device that was the previous protocol master of the same Virtual
Chassis.
10. Choose the member device with the lowest media access control (MAC) address.
Copyright © 2017, Juniper Networks, Inc.
33
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Related
Documentation
•
Virtual Chassis Components Overview on page 24
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Switching the Global Master and Backup Roles in a Virtual Chassis Configuration on
page 95
Switchover Behavior in an MX Series Virtual Chassis
When an active or primary hardware or software component fails or is temporarily shut
down, you can manually initiate a switchover to a backup component that takes over the
functions of the unavailable primary component. You can initiate two types of switchovers
in a Virtual Chassis configuration for MX Series 3D Universal Edge Routers:
•
Global switchover—Changes the mastership in an MX Series Virtual Chassis by switching
the global roles of the master router and backup router in the Virtual Chassis
configuration.
•
Local switchover—Toggles the local mastership of the dual Routing Engines in a
member router of the Virtual Chassis.
During a switchover, the roles assigned to the member routers and Routing Engines in a
Virtual Chassis configuration change. This topic describes the role transitions that occur
so you can better understand how an MX Series Virtual Chassis behaves during a global
or local switchover. The topic also describes how you can determine whether the member
routers are ready for a global graceful Routing Engine switchover (GRES) operation from
a database synchronization perspective.
•
Virtual Chassis Role Transitions During a Global Switchover on page 34
•
Virtual Chassis Role Transitions During a Local Switchover on page 35
•
Virtual Chassis Role Transitions During Virtual Chassis Formation on page 36
•
GRES Readiness in a Virtual Chassis Configuration on page 37
Virtual Chassis Role Transitions During a Global Switchover
To change the mastership in an MX Series Virtual Chassis and cause a global switchover,
you issue the request virtual-chassis routing-engine master switch command from the
master Routing Engine in the Virtual Chassis master router (VC-Mm).
After you issue the request virtual-chassis routing-engine master switch command, the
current Virtual Chassis master router (VC-M) and the current Virtual Chassis backup
router (VC-B) switch roles. The former VC-M becomes the new VC-B, and the former
VC-B becomes the new VC-M. After the VC-M and VC-B switch roles, the master Routing
Engine on the new VC-B (VC-Bm) reboots, causing the role transitions listed in
Table 6 on page 35.
34
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
Table 6: Virtual Chassis Role Transitions During Global Switchover
Virtual Chassis Role Before Global
Switchover
Virtual Chassis Role After Global Switchover
Virtual Chassis master router (VC-M)
Virtual Chassis backup router (VC-B)
Virtual Chassis backup router (VC-B)
Virtual Chassis master router (VC-M)
Master Routing Engine in the Virtual Chassis
master router (VC-Mm)
Standby Routing Engine in the Virtual Chassis
backup router (VC-Bs)
Standby Routing Engine in the Virtual Chassis
master router (VC-Ms)
Master Routing Engine in the Virtual Chassis
backup router (VC-Bm)
Master Routing Engine in the Virtual Chassis
backup router (VC-Bm)
Master Routing Engine in the Virtual Chassis
master router (VC-Mm)
Standby Routing Engine in the Virtual Chassis
backup router (VC-Bs)
Standby Routing Engine in the Virtual Chassis
master router (VC-Ms)
The local roles (master and standby, or m and s) of the Routing Engines in the Virtual
Chassis master router change after a global switchover, but the local roles of the Routing
Engines in the Virtual Chassis backup router do not change. For example, as shown in
Table 6 on page 35, the master Routing Engine in the Virtual Chassis master router
(VC-Mm) becomes the standby Routing Engine in the Virtual Chassis backup router
(VC-Bs) after the global switchover. By contrast, the master Routing Engine in the Virtual
Chassis backup router (VC-Bm) remains the master Routing Engine in the Virtual Chassis
master router (VC-Mm) after the global switchover.
Virtual Chassis Role Transitions During a Local Switchover
To ensure redundancy in a two-member Virtual Chassis configuration, each of the two
member routers must be configured with dual Routing Engines. To toggle local mastership
between the master Routing Engine and the standby Routing Engine in the member
router, you issue the request chassis routing-engine master switch command from either
the master Routing Engine in the Virtual Chassis master router (VC-Mm) or from the
master Routing Engine in the Virtual Chassis backup router (VC-Bm).
Table 7 on page 35 shows the role transitions caused by a local switchover when you
issue the request chassis routing-engine master switch command from the VC-Mm.
Table 7: Virtual Chassis Role Transitions During Local Switchover
Performed from VC-Mm
Virtual Chassis Role Before Local
Switchover
Virtual Chassis Role After Local Switchover
Master Routing Engine in the Virtual Chassis
master router (VC-Mm)
Standby Routing Engine in the Virtual Chassis
backup router (VC-Bs)
Standby Routing Engine in the Virtual Chassis
master router (VC-Ms)
Master Routing Engine in the Virtual Chassis
backup router (VC-Bm)
Copyright © 2017, Juniper Networks, Inc.
35
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 7: Virtual Chassis Role Transitions During Local Switchover
Performed from VC-Mm (continued)
Virtual Chassis Role Before Local
Switchover
Virtual Chassis Role After Local Switchover
Master Routing Engine in the Virtual Chassis
backup router (VC-Bm)
Master Routing Engine in the Virtual Chassis
master router (VC-Mm)
Standby Routing Engine in the Virtual Chassis
backup router (VC-Bs)
Standby Routing Engine in the Virtual Chassis
master router (VC-Ms)
Table 8 on page 36 shows the role transitions caused by a local switchover when you
issue the request chassis routing-engine master switch command from the VC-Bm.
Table 8: Virtual Chassis Role Transitions During Local Switchover
Performed from VC-Bm
Virtual Chassis Role Before Local
Switchover
Virtual Chassis Role After Local Switchover
Master Routing Engine in the Virtual Chassis
backup router (VC-Bm)
Standby Routing Engine in the Virtual Chassis
backup router (VC-Bs)
Standby Routing Engine in the Virtual Chassis
backup router (VC-Bs)
Master Routing Engine in the Virtual Chassis
backup router (VC-Bm)
Master Routing Engine in the Virtual Chassis
master router (VC-Mm)
Master Routing Engine in the Virtual Chassis
master router (VC-Mm)
Standby Routing Engine in the Virtual Chassis
master router (VC-Ms)
Standby Routing Engine in the Virtual Chassis
master router (VC-Ms)
When you perform a local switchover, the master (m) and standby (s) local roles of the
Routing Engines in each member router change only in the member router from which
you issue the request chassis routing-engine master switch command. For example, when
you issue a local switchover from the VC-Mm, as shown in Table 7 on page 35, the local
roles change on the VC-M but remain the same on the VC-B. Conversely, when you issue
a local switchover from the VC-Bm, as shown in Table 8 on page 36, the local roles
change on the VC-B but remain the same on the VC-M.
A local switchover performed from the VC-Mm also changes the global roles of the
member routers, as shown in Table 7 on page 35. By contrast, a local switchover performed
from the VC-Bm changes only the local roles of the Routing Engines, as shown in
Table 8 on page 36.
Virtual Chassis Role Transitions During Virtual Chassis Formation
In the rare case when the virtual chassis has "split" (that is, lost connectivity), each
member may take the Virtual Chassis master router (VC-M) role, resulting in two VC-M
chassis. When Virtual Chassis connectivity is restored, an election process assigns the
Virtual Chassis master (VC-M) role to one member and the Virtual Chassis backup (VC-B)
36
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
role to the other member. As of Junos OS Release 15.1, in the same manner as the global
GRES behavior, the newly elected VC-B member causes its local master Routing Engine
to reboot after passing local mastership to its local standby Routing Engine. This is an
intentional action which allows the VC-B chassis to become GRES-ready more quickly.
NOTE: Rebooting both Routing Engines in the VC-M chassis may not result
in a graceful switchover to the VC-B chassis, and is not recommended.
GRES Readiness in a Virtual Chassis Configuration
Depending on the configuration, a variable amount of time is required before a router is
ready to perform a graceful Routing Engine switchover (GRES). Attempting a GRES
operation before the router is ready can cause system errors and unexpected behavior.
To determine whether the member routers in an MX Series Virtual Chassis configuration
are ready for a GRES operation from a database synchronization perspective, you can
issue the request virtual-chassis routing-engine master switch check command from the
Virtual Chassis master router (VC-Mm) before you initiate the GRES operation.
The request virtual-chassis routing-engine master switch check command checks various
system and database components on the member routers to determine whether they
are ready for GRES, but does not initiate the global GRES operation itself. The readiness
check includes ensuring that a system timer, which expires after 300 seconds, completes
before the global GRES operation begins.
Using the request virtual-chassis routing-engine master switch check command before
you initiate the GRES operation ensures that the subscriber management and kernel
databases on both member routers in an MX Series or Virtual Chassis are synchronized
and ready for the GRES operation.
Related
Documentation
•
Switching the Global Master and Backup Roles in a Virtual Chassis Configuration on
page 95
•
Determining GRES Readiness in a Virtual Chassis Configuration on page 185
•
Virtual Chassis Components Overview on page 24
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Mastership Election in a Virtual Chassis on page 32
•
Understanding Graceful Routing Engine Switchover
Copyright © 2017, Juniper Networks, Inc.
37
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Split Detection Behavior in a Virtual Chassis
If there is a disruption to a Virtual Chassis configuration for MX Series 3D Universal Edge
Routers or EX9200 Switches due to the failure of a member router or switch or one or
more Virtual Chassis port interfaces, the resulting connectivity loss can cause a split in
the Virtual Chassis configuration. Split detection identifies the split and can minimize
further network disruption.
This topic covers:
•
How Split Detection Works in a Virtual Chassis on page 38
•
Effect of Split Detection on Virtual Chassis Failure Scenarios on page 38
How Split Detection Works in a Virtual Chassis
Split detection is enabled by default in an EX9200 or MX Series Virtual Chassis. Optionally,
you can disable split detection by including the no-split-detection statement at the [edit
virtual-chassis] hierarchy level. Disabling split detection can be useful in certain Virtual
Chassis configurations.
For example, if the backup router or switch fails in a two-member Virtual Chassis
configuration and split detection is enabled (the default behavior), the master router or
switch takes a line-card role, and the line cards (FPCs) that do not host Virtual Chassis
ports go offline. This state effectively halts routing and disables the Virtual Chassis
configuration. By contrast, if the backup router or switch fails in a two-member Virtual
Chassis configuration and split detection is disabled, the master router or switch retains
mastership and maintains all of the Virtual Chassis ports, effectively resulting in a
single-member Virtual Chassis consisting of only the master router or switch.
BEST PRACTICE: We recommend that you disable split detection for a
two-member Virtual Chassis configuration if you think the backup router or
switch is more likely to fail than the Virtual Chassis port interfaces to the
backup router or switch. Configuring redundant Virtual Chassis ports on
different line cards in each member router or switch reduces the likelihood
that all Virtual Chassis port interfaces to the backup router or switch can fail.
Effect of Split Detection on Virtual Chassis Failure Scenarios
The behavior of a Virtual Chassis during certain failure scenarios depends on whether
split detection is enabled or disabled. Table 9 on page 39 describes the effect of the split
detection setting on common failure scenarios in a two-member MX Series Virtual Chassis.
38
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
Table 9: Effect of Split Detection on Common Virtual Chassis Failure
Scenarios
Type of Failure
Virtual Chassis port
interfaces go down
Split Detection
Setting
Results
Enabled
•
VC-B takes VC-M role.
•
Previous VC-M takes line-card (VC-L)
role. The line-card role isolates the
router or switch and removes it from
the Virtual Chassis until connectivity is
restored.
•
Result is a single-member Virtual
Chassis consisting of only a single
VC-M. The VC-M continues to maintain
subscriber state information and route
traffic.
When Virtual Chassis port interfaces are
reconnected:
Virtual Chassis port
interfaces go down
Disabled
•
VC-M retains VC-M role.
•
VC-L takes VC-B role.
•
Subscribers are not affected.
When Virtual Chassis port interfaces are
disconnected:
•
VC-M retains VC-M role, and VC-B also
takes VC-M role. The result is a Virtual
Chassis with two VC-M routers or
switches, each of which maintains
subscriber state information.
•
Initially, both VC-M routers or switches
have a complete list of subscribers.
Because the two routers or switches
have the same configuration, the effect
on subscribers, traffic patterns, behavior
of external applications, and subscriber
login and logout operations is
unpredictable while the Virtual Chassis
port interfaces are disconnected.
When Virtual Chassis port interfaces are
reconnected:
Copyright © 2017, Juniper Networks, Inc.
•
Original VC-M before the disconnection
resumes VC-M role, and original VC-B
before the disconnection resumes VC-B
role.
•
Subscribers on the VC-M are preserved.
•
Subscribers on the VC-B are purged.
•
The subscribers preserved on the VC-M
are unaffected, and all remaining
subscribers are able to log back in to
the router or switch.
39
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 9: Effect of Split Detection on Common Virtual Chassis Failure
Scenarios (continued)
Type of Failure
Virtual Chassis backup
router or switch (VC-B)
goes down
Split Detection
Setting
Results
Enabled
•
VC-M takes line-card (VC-L) role, which
causes all line cards (FPCs) that do not
host Virtual Chassis ports to go offline.
•
Previous VC-B is out of service.
•
The line-card role isolates the master
router or switch and removes it from
the Virtual Chassis until connectivity is
restored. As a result, the Virtual Chassis
is left without a master router or switch,
which halts interchassis routing and
effectively disables the Virtual Chassis
configuration.
When the failed router or switch is brought
back into service:
Virtual Chassis backup
router or switch (VC-B)
goes down
Virtual Chassis master
router or switch (VC-M)
goes down
Disabled
Split detection setting
has no effect on
behavior
•
The mastership election algorithm is
run to determine whether the router or
switch takes a VC-M or VC-B role. The
Virtual Chassis then becomes
operational.
•
All subscribers can log back in to the
router or switch.
•
Previous subscriber state information
is not preserved.
•
VC-M retains VC-M role and maintains
all Virtual Chassis ports.
•
Previous VC-B is out of service.
•
Result is a single-member Virtual
Chassis consisting of only a single
VC-M. The VC-M continues to maintain
subscriber state information and route
traffic.
•
VC-B takes over VC-M role regardless
of whether split detection is enabled or
disabled.
•
Previous VC-M is out of service.
•
Result is a single-member Virtual
Chassis consisting of only a single
VC-M. The new VC-M continues to
maintain subscriber state information
and route traffic.
When the original VC-M is brought back
into service, or when the original VC-M is
replaced with a new router or switch:
40
•
Original VC-M or its replacement takes
VC-B role.
•
Subscribers are not affected.
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
Table 9: Effect of Split Detection on Common Virtual Chassis Failure
Scenarios (continued)
Type of Failure
Active access link between
the VC-M and the access
node, such as a digital
subscriber line access
multiplexer (DSLAM), goes
down
Related
Documentation
Split Detection
Setting
Split detection setting
has no effect on
behavior
Results
•
Previous standby access link becomes
the active access link between the VC-B
and the access node.
•
Traffic is routed through the new active
access link.
•
The VC-M continues to maintain
subscriber state information and route
traffic.
•
Virtual Chassis Components Overview on page 24
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Mastership Election in a Virtual Chassis on page 32
•
Switchover Behavior in an MX Series Virtual Chassis on page 34
•
Disabling Split Detection in a Virtual Chassis Configuration on page 98
Virtual Chassis Heartbeat Connection Overview
Starting in Junos OS Release 14.1, you can configure an IP-based, bidirectional “heartbeat”
packet connection between the master router and backup router in an MX Series Virtual
Chassis. You can use this heartbeat connection to determine the health and availability
of member routers in the Virtual Chassis. The member routers forming this heartbeat
connection exchange heartbeat packets that provide critical information about the
availability and health of each member router. During a disruption or split in the Virtual
Chassis configuration, the heartbeat connection prevents the member routers from
changing mastership roles unnecessarily. Without the heartbeat connection, a change
in mastership roles in such a situation can produce undesirable results, such as having
two Virtual Chassis master routers or no Virtual Chassis master router.
•
Benefits of Configuring a Virtual Chassis Heartbeat Connection on page 41
•
Configuration Requirements for the Heartbeat Connection on page 42
•
How the Heartbeat Connection Works on page 44
•
Heartbeat Connection and Virtual Chassis Failure Conditions on page 45
•
Heartbeat Connection Compared to Split Detection on page 45
Benefits of Configuring a Virtual Chassis Heartbeat Connection
Configuring a Virtual Chassis heartbeat connection provides the following benefits for
an MX Series Virtual Chassis:
•
Improved resiliency during failure scenarios
Copyright © 2017, Juniper Networks, Inc.
41
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Configuring the heartbeat connection improves resiliency of the Virtual Chassis in the
event of an adjacency disruption or split caused by a failure of the Virtual Chassis port
interfaces, or when one of the member routers goes out of service. If the heartbeat
connection detects that the Virtual Chassis master router (VC-M) is still operating and
able to respond during a split, the software maintains mastership on the existing VC-M,
isolates the Virtual Chassis backup router (VC-B) until the Virtual Chassis recovers,
and resumes the backup role on the VC-B when the Virtual Chassis forms again. As a
result, the heartbeat connection prevents the member routers from unnecessarily
changing mastership roles, which consumes system resources and causes unexpected
and undesirable results.
When the VC-B is isolated during a disruption, the software immediately restarts all
line cards and powers off all network ports until the disruption is resolved and the
Virtual Chassis forms again. This behavior supports network applications with external
equipment that requires a physical link-down condition to switch the traffic paths to
other connections.
•
Enhanced mastership election process
The Virtual Chassis Control Protocol (VCCP) controls mastership election in a Virtual
Chassis. When you configure the heartbeat connection in an MX Series Virtual Chassis,
the VCCP software assesses the health information collected from the heartbeat
connection to help determine which member router should become the global master
(VC-M) in the event of an adjacency disruption or split. When the heartbeat connection
detects that the peer member router is responsive, the VCCP software suppresses
unnecessary changes in mastership roles.
By contrast, when the heartbeat connection is not configured, the VCCP software does
not have this additional health information when determining the appropriate
mastership roles after a disruption or split.
•
Ability to easily view and clear statistics related to the heartbeat connection
Operational commands for the Virtual Chassis enable you to display the status of the
heartbeat connection, review detailed statistics and latency measurements related
to the heartbeat connection, and clear heartbeat-related statistics counters and
timestamp fields for one or both member routers.
Configuration Requirements for the Heartbeat Connection
To establish a heartbeat connection for an MX Series Virtual Chassis, you must configure
a secure and reliable route between the master router and backup router for the exchange
of TCP/IP heartbeat packets. Specifically, you must ensure that the master Routing
Engine in the Virtual Chassis backup router (VC-Bm) can make a TCP/IP connection to
the master-only IP address of the master Routing Engine in the Virtual Chassis master
router (VC-Mm).
42
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
The following additional requirements apply when you configure the heartbeat connection:
•
Configure the heartbeat connection only between Virtual Chassis member routers
eligible to become the Virtual Chassis master router, also known as the protocol master
or global master.
In a two-member MX Series Virtual Chassis configuration, you assign the routing-engine
role to each router as part of the preprovisioned configuration. The routing-engine role
enables the router to function either as the master router or backup router of the Virtual
Chassis as needed. As a result, you can configure the heartbeat connection between
both member routers in a two-member MX Series Virtual Chassis configuration.
•
Use the router’s Ethernet management interface (fxp0) as the heartbeat path.
The management interface is generally available earlier than the line card interfaces,
and is typically connected to a more secure network than the other interfaces.
•
Configure a master-only IP address for the fxp0 management interface to ensure
consistent access to the VC-Mm, regardless of which Routing Engine is currently active.
The master-only address is active only on the management interface for the VC-Mm.
During a switchover, the master-only address moves to the new Routing Engine currently
functioning as the VC-Mm.
•
Ensure TCP connectivity between the VC-Mm and VC-Bm member routers
The Virtual Chassis heartbeat connection opens a proprietary TCP port numbered
33087 on the VC-Mm to listen for heartbeat messages. If your network design includes
firewalls or filters, make sure the network allows traffic between TCP port 33087 on
the VC-Mm and the dynamically allocated TCP port on the VC-Bm.
•
When using a heartbeat connection, do not configure the no-split-detection statement
as part of the preprovisioned Virtual Chassis configuration.
The no-split-detection statement suppresses any action when a split is detected in the
Virtual Chassis. Using the no-split-detection statement is prohibited when you configure
a heartbeat connection, and the software prevents you from configuring both the
no-split-detection and heartbeat-address statements at the same time. If you attempt
to do so, the software displays an error message and causes the commit operation to
fail.
In a two-member MX Series Virtual Chassis, you can configure a heartbeat connection
with both member routers in the same subnet, or with each member router in a different
subnet. Table 10 on page 44 summarizes the important differences between the
configuration procedures for member routers in the same subnet and member routers
in different subnets.
Copyright © 2017, Juniper Networks, Inc.
43
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 10: Comparison of Heartbeat Connection Configuration Tasks for Member Routers in
Same Subnet and Member Routers in Different Subnets
Heartbeat Connection for Member Routers
in Same Subnet
Heartbeat Connection for Member Routers
in Different Subnets
Configure the master-only
IP address for fxp0
management interface.
Configure the same fxp0 master-only IP address
for all four member Routing Engines.
Configure two different master-only IP
addresses for the fxp0 management interface:
one address for the subnet in which the Virtual
Chassis master router resides, and one for the
subnet in which the backup router resides.
Configure a network path
for the heartbeat
connection.
Provide a path for the member routers to reach
each other by means of a TCP/IP connection.
Provide a path for the member routers to reach
each other by means of a TCP/IP connection.
In a Virtual Chassis with member routers in
different subnets, you must ensure that both
member routers can reach each other’s
network.
Task
For example, in a Virtual Chassis with member
routers in the same subnet, you can use the
router’s default gateway. Alternatively, you can
create a global static route as described in
“Example: Determining Member Health Using
an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same
Subnet” on page 196.
Configure the heartbeat
address to establish the
heartbeat connection.
Configure a single (global) master-only IP
address for the fxp0 management interface as
the heartbeat address to establish the
connection.
For example, you can create static routes to
both subnets on each member Routing Engine,
as described in “Example: Determining Member
Health Using an MX Series Virtual Chassis
Heartbeat Connection with Member Routers in
Different Subnets” on page 207.
Configure a heartbeat address for each member
Routing Engine to cross-connect to the
master-only IP address for the corresponding
Routing Engine in the other subnet.
For example, assume that member0-re0 and
member0-re1 reside in subnet 10.4.0.0, and
member1-re0 and member1-re1 reside in subnet
10.5.0.0. In this configuration, you would set the
heartbeat address for member0-re0 to the
master-only IP address for member1-re0 to
cross-connect member0-re0 and member1-re0.
You would cross-connect member0-re1 and
member1-re1 in a similar manner.
How the Heartbeat Connection Works
When the Virtual Chassis is operating properly, the heartbeat connection periodically
sends heartbeat packets over the TCP/IP path between the master Routing Engine in
the Virtual Chassis master router and the master Routing Engine in the Virtual Chassis
backup router.
When an adjacency disruption or split is detected in the Virtual Chassis, each member
router sends a final heartbeat message to determine whether the other member is able
to respond, and stops sending additional periodic messages until the Virtual Chassis
forms again. The other member must respond to the heartbeat message within the
default heartbeat timeout period (2 seconds), or within a configured heartbeat timeout
period in the range 1 through 60 seconds. To determine the time period that elapses in
your network between transmission of a heartbeat request message and receipt of a
heartbeat response message, you can issue the show virtual-chassis heartbeat detail
44
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
command to view the number of seconds reported in the Maximum latency and Minimum
latency fields.
BEST PRACTICE: If your network is congested or has a round-trip latency
that exceeds 2 seconds, we recommend that you increase the value of the
heartbeat timeout period to account for this delay during a Virtual Chassis
adjacency disruption or split.
Heartbeat Connection and Virtual Chassis Failure Conditions
Configuring the heartbeat connection prevents unnecessary mastership role changes
between the Virtual Chassis member routers when an adjacency disruption or split occurs.
Table 11 on page 45 describes the effects on mastership for common failure conditions
when you enable the heartbeat connection in a two-member MX Series Virtual Chassis.
Table 11: Effect of Heartbeat Connection on Common Virtual Chassis Failure Conditions
Result on Virtual Chassis Master Router
(VC-M)
Result on Virtual Chassis Backup Router
(VC-B)
Virtual Chassis port interfaces go
down.
Retains VC-M role.
If the VC-M is in service but the Virtual
Chassis port interfaces are down, the VC-B
goes offline after the heartbeat timeout
period expires because the Routing Engine
state is invalid.
VC-M chassis fails.
Goes out of service.
Becomes VC-M.
VC-B chassis fails.
Retains VC-M role.
Goes out of service.
Heartbeat connection fails.
Retains VC-M role.
Retains VC-B role.
Failure Condition
In all cases except when the VC-M chassis fails, mastership of the Virtual Chassis is
maintained on the existing VC-Mm if the heartbeat connection detects that the VC-M is
still operating and able to respond during a split. Preventing an unnecessary role change
minimizes the system load caused by a protocol mastership switch, and reduces the
liklihood of unpredictable results.
Heartbeat Connection Compared to Split Detection
In certain Virtual Chassis failure conditions, the split detection setting (enabled by default,
or explicitly disabled) can cause unpredictable and undesirable results such as a Virtual
Chassis with two master routers, or a Virtual Chassis with no master router.
Table 12 on page 46 compares the effects of split detection and the heartbeat connection
for two common failure conditions: failure of the Virtual Chassis port interfaces and
failure of the VC-B chassis.
Copyright © 2017, Juniper Networks, Inc.
45
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 12: Comparison of Heartbeat Connection and Split Detection for Virtual Chassis Failure
Conditions
Failure Condition
Results with Heartbeat Connection
Results with Split Detection
Virtual Chassis port interfaces go
down.
•
VC-M chassis retains VC-M role.
When split detection is disabled:
•
If the VC-M chassis is in service but the
Virtual Chassis port interfaces are down,
the VC-B chassis goes offline after the
heartbeat timeout period expires because
the Routing Engine state is invalid.
VC-B chassis fails.
•
VC-M chassis retains VC-M role.
•
VC-B chassis is out of service.
•
VC-M chassis retains VC-M role.
•
VC-B chassis also takes VC-M role.
•
Virtual Chassis has two master routers,
each of which maintains subscriber state
information. The effect on subscribers,
traffic patterns, behavior of external
applications, and subscriber login and
logout operations is unpredictable while
the Virtual Chassis port interfaces are
disconnected.
When split detection is enabled:
•
VC-M chassis takes line-card (VC-L) role,
which isolates and removes it from the
Virtual Chassis until connectivity is
restored.
•
VC-B chassis is out of service.
•
Virtual Chassis does not have a master
router. This state halts interchassis routing
and effectively disables the Virtual Chassis
configuration.
BEST PRACTICE: We recommend that you use the heartbeat connection
instead of the split detection feature in an MX Series Virtual Chassis to avoid
unnecessary mastership role changes during an adjacency disruption or split,
and to provide additional member health information for the mastership
election process.
Release History Table
Related
Documentation
46
Release
Description
14.1
Starting in Junos OS Release 14.1, you can configure an IP-based, bidirectional
“heartbeat” packet connection between the master router and backup router
in an MX Series Virtual Chassis.
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Split Detection Behavior in a Virtual Chassis on page 38
•
Configuring a Consistent Management IP Address
Command Forwarding in a Virtual Chassis
You can run some CLI commands on all member routers, on the local member router, or
on a specific member router in an MX Series Virtual Chassis configuration. This feature
is referred to as command forwarding. With command forwarding, the router sends the
command to the specified member router or routers, and displays the results as if the
command were processed on the local router.
For example, to collect information about your system prior to contacting Juniper Networks
Technical Assistance Center (JTAC), use the command request support information
all-members to gather data for all the member routers. If you want to gather this data
only for a particular member router, use the command request support information member
member-id.
Table 13 on page 47 describes the commands that you can run on all (both) member
routers (with the all-members option), on the local member router (with the local option),
or on a specific member router (with the member member-id option) in an MX Series
Virtual Chassis configuration, where member-id is 0 or 1.
Table 13: Commands Available for Command Forwarding in an MX Series Virtual Chassis
Command
Purpose
all-members
local
member member-id
request chassis fpc
Control the operation
of the Flexible PIC
Concentrator (FPC).
Change FPC status of
all members of the
Virtual Chassis
configuration.
(Default) Change FPC
status of the local
member of the Virtual
Chassis.
Change FPC status of
the specified member
of the Virtual Chassis.
request chassis fpm
resync
Resynchronize the
craft interface status.
Resynchronize the craft
interface status on all
members of the Virtual
Chassis configuration.
(Default)
Resynchronize the craft
interface status on the
local member of the
Virtual Chassis.
Resynchronize the craft
interface status on the
specified member of
the Virtual Chassis.
request chassis pic
Change the PIC status
of the specified
member router.
—
—
Change the PIC status
on the specified
member of the Virtual
Chassis.
request chassis
routing-engine master
Control which Routing
Engine is the master
for a router with dual
Routing Engines.
Control Routing Engine
mastership on the
Routing Engines in all
member routers of the
Virtual Chassis
configuration.
(Default) Control
Routing Engine
mastership on the
Routing Engines in the
local Virtual Chassis
configuration.
Control Routing Engine
mastership on the
Routing Engines of the
specified member in the
Virtual Chassis
configuration.
Copyright © 2017, Juniper Networks, Inc.
47
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
request chassis sfb
(MX2010 and MX2020
routers only) Control
the operation of the
Switch Fabric Board
(SFB).
Control the operation
of the SFB in all
members of the Virtual
Chassis configuration.
(Default) Control the
operation of the SFB in
the local member of
the Virtual Chassis.
Control the operation of
the SFB in the specified
member of the Virtual
Chassis.
request chassis spmb
restart
(MX2010 and MX2020
routers only) Restart
the specified Switch
Processor Mezzanine
Board (SPMB) on the
Control Board (CB).
Restart the SPMB on
the CB in all members
of the Virtual Chassis
configuration.
(Default) Restart the
SPMB on the CB in the
local member of the
Virtual Chassis.
Restart the SPMB on
the CB in the specified
member of the Virtual
Chassis.
request routing-engine
login
Specify a tty
connection for login for
a router with two
Routing Engines.
Log in to all members
of the Virtual Chassis
configuration.
(Default) Log in to the
local member of the
Virtual Chassis.
Log in to the specified
member of the Virtual
Chassis.
request support
information
Display information
about the system.
(Default) Display
system information for
all members of the
Virtual Chassis
configuration.
Display system
information for the
local member of the
Virtual Chassis.
Display system
information for the
specified member of
the Virtual Chassis.
request system halt
Stop the router.
(Default) Halt all
members of the Virtual
Chassis configuration.
Halt the local member
of the Virtual Chassis.
Halt the specified
member of the Virtual
Chassis.
request system
partition abort
Terminate a previously
scheduled storage
media partition
operation.
(Default) Abort a
previously scheduled
storage media partition
operation for all
members of the Virtual
Chassis configuration.
Abort a previously
scheduled storage
media partition
operation for the local
member of the Virtual
Chassis.
Abort a previously
scheduled storage
media partition
operation for the
specified member of
the Virtual Chassis
member.
request system
partition hard-disk
Set up the hard disk for
partitioning.
(Default) Schedule a
partition of the hard
disk for all members of
the Virtual Chassis
configuration.
Schedule a partition of
the hard disk for the
local member of the
Virtual Chassis.
Schedule a partition of
the hard disk for the
specified member of
the Virtual Chassis.
request system
power-off
Power off the
software.
(Default) Power off all
members of the Virtual
Chassis configuration.
Power off the local
member of the Virtual
Chassis.
Power off the specified
member of the Virtual
Chassis.
request system reboot
Reboot the software.
(Default) Reboot the
software on all
members of the Virtual
Chassis configuration.
Reboot the software
on the local member of
the Virtual Chassis.
Reboot the software on
the specified member
of the Virtual Chassis.
48
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
request system
snapshot
Back up the currently
running and active file
system partitions on
the router to standby
partitions that are not
running.
(Default) Archive data
and executable areas
for all members of the
Virtual Chassis
configuration.
Archive data and
executable areas for
the local member of
the Virtual Chassis.
Archive data and
executable areas for the
specified member of
the Virtual Chassis.
request system
software add
Install a software
package or bundle on
the router.
(Default if no options
specified) Install a
software package on
all members of the
Virtual Chassis
configuration.
—
Install a software
package on the
specified member of
the Virtual Chassis.
request system
software rollback
Revert to the software
that was loaded at the
last successful request
(Default) Attempt to
roll back to the
previous set of
packages on all
members of the Virtual
Chassis configuration.
Attempt to roll back to
the previous set of
packages on the local
member of the Virtual
Chassis.
Attempt to roll back to
the previous set of
packages on the
specified member of
the Virtual Chassis.
system software add
command.
request system
software validate
Validate candidate
software against the
current configuration
of the router.
—
(Default if no options
specified) Validate the
software package on
the local member of
the Virtual Chassis.
Validate the software
bundle or package on
the specified member
of the Virtual Chassis.
request system storage
cleanup
Free storage space on
the router or switch by
rotating log files and
proposing a list of files
for deletion.
(Default) Delete files
on all members of the
Virtual Chassis
configuration.
Delete files on the local
member of the Virtual
Chassis.
Delete files on the
specified member of
the Virtual Chassis.
restart
Restart a Junos OS
process.
Restart the software
process for all
members of the Virtual
Chassis configuration.
(Default) Restart the
software process for
the local member of
the Virtual Chassis.
Restart the software
process for a specified
member of the Virtual
Chassis.
show chassis adc
(MX2010 and MX2020
routers only) Display
information about the
adapter cards (ADCs).
(Default) Display
information about the
ADCs in all members of
the Virtual Chassis
configuration.
Display information
about the ADCs in the
local member of the
Virtual Chassis.
Display information
about the ADCs in the
specified member of
the Virtual Chassis.
show chassis alarms
Display information
about the conditions
that have been
configured to trigger
alarms.
(Default) Display
information about
alarm conditions for all
the member routers of
the Virtual Chassis
configuration.
Display information
about alarm conditions
for the local member
of the Virtual Chassis.
Display information
about alarm conditions
for the specified
member of the Virtual
Chassis.
Copyright © 2017, Juniper Networks, Inc.
49
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
show chassis
craft-interface
View messages
currently displayed on
the craft interface.
(Default) Display
information currently
on the craft interface
for all members of the
Virtual Chassis
configuration.
Display information
currently on the craft
interface for the local
member of the Virtual
Chassis.
Display information
currently on the craft
interface for the
specified member of
the Virtual Chassis.
show chassis
environment
Display environmental
information about the
router or switch
chassis, including the
temperature and
information about the
fans, power supplies,
and Routing Engine.
(Default) Display
chassis environmental
information for all the
members of the Virtual
Chassis configuration.
Display chassis
environmental
information for the
local member of the
Virtual Chassis.
Display chassis
environmental
information for the
specified member of
the Virtual Chassis.
show chassis
environment adc
(MX2010 and MX2020
routers only) Display
chassis environmental
information about the
adapter cards (ADCs).
(Default) Display
chassis environmental
information about the
ADCs in all members of
the Virtual Chassis
configuration.
Display chassis
environmental
information about the
ADCs in the local
member of the Virtual
Chassis.
Display chassis
environmental
information about the
ADCs in the specified
member of the Virtual
Chassis.
show chassis
environment cb
Display environmental
information about the
Control Boards (CBs).
(Default) Display
environmental
information about the
CBs on all the
members of the Virtual
Chassis configuration.
Display environmental
information about the
CBs on the local
member of the Virtual
Chassis.
Display environmental
information about the
CBs on the specified
member of the Virtual
Chassis.
show chassis
environment fan
(MX2010 and MX2020
routers only) Display
environmental
information about the
fans and fan trays.
(Default) Display
environmental
information about the
fans and fan trays in all
members of the Virtual
Chassis configuration.
Display environmental
information about the
fans and fan trays in
the local member of
the Virtual Chassis.
Display environmental
information about the
fans and fan trays in the
specified member of
the Virtual Chassis.
show chassis
environment fpc
Display environmental
information about
Flexible PIC
Concentrators (FPCs).
(Default) Display
environmental
information for the
FPCs in all the
members of the Virtual
Chassis configuration.
Display environmental
information for the
FPCs in the local
member of the Virtual
Chassis.
Display environmental
information for the
FPCs in the specified
member of the Virtual
Chassis.
show chassis
environment monitored
(MX2010 and MX2020
routers only) Display
status information for
monitored
temperatures.
(Default) Display
status information for
monitored
temperatures in all
members of the Virtual
Chassis configuration.
Display status
information for
monitored
temperatures in the
local member of the
Virtual Chassis.
Display status
information for
monitored
temperatures in the
specified member of
the Virtual Chassis.
50
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
show chassis
environment pem
Display Power Entry
Module (PEM)
environmental status
information.
(Default) Display
environmental
information about the
PEMs in all the
member routers of the
Virtual Chassis
configuration.
Display environmental
information about the
PEMs in the local
member of the Virtual
Chassis.
Display environmental
information about the
PEMs in the specified
member of the Virtual
Chassis.
show chassis
environment psm
(MX2010 and MX2020
routers only) Display
chassis environmental
information about the
power supply modules
(PSMs).
(Default) Display
chassis environmental
information about the
PSMs in all member
routers of the Virtual
Chassis configuration.
Display chassis
environmental
information about the
PSMs in the local
member of the Virtual
Chassis.
Display chassis
environmental
information about the
PSMs in the specified
member of the Virtual
Chassis.
show chassis
environment
routing-engine
Display Routing Engine
environmental status
information.
(Default) Display
environmental
information about the
Routing Engines in all
member routers in the
Virtual Chassis
configuration.
Display environmental
information about the
Routing Engines in the
local member of the
Virtual Chassis.
Display environmental
information about the
Routing Engines in the
specified member of
the Virtual Chassis.
show chassis
environment sfb
(MX2010 and MX2020
routers only) Display
chassis environmental
information about the
Switch Fabric Boards
(SFBs).
(Default) Display
chassis environmental
information about the
SFBs in all member
routers in the Virtual
Chassis configuration.
Display chassis
environmental
information about the
SFBs in the local
member of the Virtual
Chassis.
Display chassis
environmental
information about the
SFBs in the specified
member of the Virtual
Chassis.
show chassis
ethernet-switch
Display information
about the ports on the
Control Board (CB)
Ethernet switch.
(Default) Display
information about the
ports on the CB
Ethernet switch on all
the members of the
Virtual Chassis
configuration.
Display information
about the ports on the
CB Ethernet switch on
the local member of
the Virtual Chassis.
Display information
about the ports on the
CB Ethernet switch on
the specified member
of the Virtual Chassis.
show chassis fabric
fpcs
Display the state of the
electrical and optical
switch fabric links
between the Flexible
PIC Concentrators
(FPCs) and the Switch
Interface Boards
(SIBs).
(Default) Display the
switching fabric link
states for the FPCs in
all members of the
Virtual Chassis
configuration.
Display the switching
fabric link states for the
FPCs in the local
member of the Virtual
Chassis.
Display the switching
fabric link states for the
FPCs in the specified
member of the Virtual
Chassis.
show chassis fabric
map
Display the switching
fabric map state.
(Default) Display the
switching fabric map
state for all the
members of the Virtual
Chassis configuration.
Display the switching
fabric map state for
the local member of
the Virtual Chassis.
Display the switching
fabric map state for the
specified member of
the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
51
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
show chassis fabric
plane
Display the state of all
fabric plane
connections.
(Default) Display the
state of all fabric plane
connections on all
members of the Virtual
Chassis configuration.
Display the state of all
fabric plane
connections on the
local member of the
Virtual Chassis.
Display the state of all
fabric plane
connections on the
specified member of
the Virtual Chassis.
show chassis fabric
plane-location
Display the Control
Board (CB) location of
each plane on both the
master and backup
Routing Engine.
(Default) Display the
CB location of each
fabric plane on the
Routing Engines in all
member routers in the
Virtual Chassis
configuration.
Display the CB location
of each fabric plane on
the Routing Engines in
the local member of
the Virtual Chassis.
Display the CB location
of each fabric plane on
the Routing Engines in
the specified member in
the Virtual Chassis
configuration.
show chassis fan
Display information
about the fan tray and
fans.
(Default) Display
information about the
fan tray and fans for all
members of the Virtual
Chassis configuration.
Display information
about the fan tray and
fans for the local
member of the Virtual
Chassis.
Display information
about the fan tray and
fans for the specified
member of the Virtual
Chassis.
show chassis firmware
Display the version
levels of the firmware
running on the System
Control Board (SCB),
Switching and
Forwarding Module
(SFM), System and
Switch Board (SSB),
Forwarding Engine
Board (FEB), Flexible
PIC Concentrators
(FPCs), and Routing
Engines.
(Default) Display the
version levels of the
firmware running for all
members of the Virtual
Chassis configuration.
Display the version
levels of the firmware
running for the local
member of the Virtual
Chassis.
Display the version
levels of the firmware
running for the specified
member of the Virtual
Chassis.
show chassis fpc
Display status
information about the
installed Flexible PIC
Concentrators (FPCs)
and PICs.
(Default) Display
status information for
all FPCs on all
members of the Virtual
Chassis configuration.
Display status
information for all
FPCs on the local
member of the Virtual
Chassis.
Display status
information for all FPCs
on the specified
member of the Virtual
Chassis.
show chassis hardware
Display a list of all
Flexible PIC
Concentrators (FPCs)
and PICs installed in
the router or switch
chassis, including the
hardware version level
and serial number.
(Default) Display
hardware-specific
information for all the
members of the Virtual
Chassis configuration.
Display
hardware-specific
information for the
local member of the
Virtual Chassis.
Display
hardware-specific
information for the
specified member of
the Virtual Chassis.
52
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
show chassis location
Display the physical
location of the chassis.
(Default) Display the
physical location of the
chassis for all the
member routers in the
Virtual Chassis
configuration.
Display the physical
location of the chassis
for the local member
of the Virtual Chassis.
Display the physical
location of the chassis
for the specified
member of the Virtual
Chassis.
show chassis
mac-addresses
Display the media
access control (MAC)
addresses for the
router, switch chassis,
or switch.
(Default) Display the
MAC addresses for all
the member routers of
the Virtual Chassis
configuration.
Display the MAC
addresses for the local
member of the Virtual
Chassis.
Display the MAC
addresses for the
specified member of
the Virtual Chassis.
show chassis pic
Display status
information about the
PIC installed in the
specified Flexible PIC
Concentrator (FPC)
and PIC slot.
(Default) Display PIC
information for all
member routers in the
Virtual Chassis
configuration.
Display PIC information
for the local member
of the Virtual Chassis.
Display PIC information
for the specified
member of the Virtual
Chassis.
show chassis power
Display power limits
and usage information
for the AC or DC power
sources.
(Default) Display
power usage
information for all
members of the Virtual
Chassis configuration.
Display power usage
information for the
local member of the
Virtual Chassis.
Display power usage
information for the
specified member of
the Virtual Chassis.
show chassis
routing-engine
Display the status of
the Routing Engine.
(Default) Display
Routing Engine
information for all
members of the Virtual
Chassis configuration.
Display Routing Engine
information for the
local member of the
Virtual Chassis.
Display Routing Engine
information for the
specified member of
the Virtual Chassis.
show chassis sfb
(MX2010 and MX2020
routers only) Display
chassis information
about the Switch
Fabric Boards (SFBs).
(Default) Display
chassis information
about the SFBs in all
members of the Virtual
Chassis configuration.
Display chassis
information about the
SFBs in the local
member of the Virtual
Chassis.
Display chassis
information about the
SFBs in the specified
member of the Virtual
Chassis.
show chassis spmb
(MX2010 and MX2020
routers only) Display
status information for
the Switch Processor
Mezzanine Boards
(SPMBs).
(Default) Display
status information for
the SPMBs in all
members of the Virtual
Chassis configuration.
Display status
information for the
SPMBs in the local
member of the Virtual
Chassis.
Display status
information for the
SPMBs in the specified
member of the Virtual
Chassis.
show chassis
temperature-thresholds
Display chassis
temperature threshold
settings, in degrees
Celsius.
(Default) Display the
chassis temperature
threshold settings of all
member routers in the
Virtual Chassis
configuration.
Display the chassis
temperature threshold
settings of the local
member of the Virtual
Chassis.
Display the chassis
temperature threshold
settings of the specified
member of the Virtual
Chassis.
Copyright © 2017, Juniper Networks, Inc.
53
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
show chassis zones
(MX2010 and MX2020
routers only) Display
the status of the
cooling system zones
of the chassis.
(Default) Display the
status of the cooling
system zones in all
members of the Virtual
Chassis configuration.
Display the status of
the cooling system
zones in the local
member of the Virtual
Chassis.
Display the status of the
cooling system zones in
the specified member
of the Virtual Chassis.
show pfe fpc
Display Packet
Forwarding Engine
statistics for the
specified Flexible PIC
Concentrator (FPC).
(Default) Display
Packet Forwarding
Engine statistics for the
specified FPC in all
members of the Virtual
Chassis configuration.
Display Packet
Forwarding Engine
statistics for the
specified FPC in the
local member of the
Virtual Chassis.
Display Packet
Forwarding Engine
statistics for the
specified FPC in the
specified member of
the Virtual Chassis.
show pfe terse
Display Packet
Forwarding Engine
status information.
(Default) Display
Packet Forwarding
Engine status
information for all
members in the Virtual
Chassis configuration.
Display Packet
Forwarding Engine
status information for
the local member of
the Virtual Chassis.
Display Packet
Forwarding Engine
status information for
the specified member
of the Virtual Chassis.
show system audit
Display the state and
checksum values for
file systems.
(Default) Display file
system MD5 hash and
permissions
information on all
members of the Virtual
Chassis configuration.
Display file system
MD5 hash and
permissions
information on the
local member of the
Virtual Chassis.
Display file system MD5
hash and permissions
information on the
specified member of
the Virtual Chassis.
show system
boot-messages
Display initial
messages generated
by the system kernel
upon startup.
(Default) Display boot
time messages on all
members of the Virtual
Chassis configuration.
Display boot time
messages on the local
member of the Virtual
Chassis.
Display boot time
messages on the
specified member of
the Virtual Chassis.
show system buffers
Display information
about the buffer pool
that the Routing
Engine uses for local
traffic.
(Default) Show buffer
statistics for all
members of the Virtual
Chassis configuration.
Show buffer statistics
for the local member
of the Virtual Chassis.
Show buffer statistics
for the specified
member of the Virtual
Chassis.
show system
connections
Display information
about the active IP
sockets on the Routing
Engine.
(Default) Display
system connection
activity for all members
of the Virtual Chassis
configuration.
Display system
connection activity for
the local member of
the Virtual Chassis.
Display system
connection activity for
the specified member
of the Virtual Chassis.
show system
directory-usage
Display directory usage
information.
Display directory
information for all
members of the Virtual
Chassis configuration.
(Default) Display
directory information
for the local member
of the Virtual Chassis.
Display directory
information for the
specified member of
the Virtual Chassis.
54
Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Understanding How a Virtual Chassis Works
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
show system processes
Display information
about software
processes that are
running on the router
and that have
controlling terminals.
(Default) Display
standard system
process information for
all members of the
Virtual Chassis
configuration.
Display standard
system process
information for the
local member of the
Virtual Chassis.
Display standard
system process
information for the
specified member of
the Virtual Chassis.
show system queues
Display queue
statistics.
(Default) Display
system queue
statistics for all
members of the Virtual
Chassis configuration.
Display system queue
statistics for the local
member of the Virtual
Chassis.
Display system queue
statistics for the
specified member of
the Virtual Chassis.
show system reboot
Display pending
system reboots or
halts.
(Default) Display halt
or reboot request
information for all
members of the Virtual
Chassis configuration.
Display halt or reboot
request information for
the local member of
the Virtual Chassis.
Display halt or reboot
request information for
the specified member
of the Virtual Chassis.
show system statistics
Display system-wide
protocol-related
statistics.
(Default) Display
system statistics for a
protocol for all
members of the Virtual
Chassis configuration.
Display system
statistics for a protocol
for the local member
of the Virtual Chassis.
Display system
statistics for a protocol
for the specified
member of the Virtual
Chassis.
show system storage
Display statistics
about the amount of
free disk space in the
router's file systems.
(Default) Display
system storage
statistics for all
members of the Virtual
Chassis configuration.
Display system storage
statistics for the local
member of the Virtual
Chassis.
Display system storage
statistics for the
specified member of
the Virtual Chassis.
show system
switchover
Display whether
graceful Routing
Engine switchover is
configured, the state
of the kernel
replication (ready or
synchronizing), any
replication errors, and
whether the primary
and standby Routing
Engines are using
compatible versions of
the kernel database.
(Default) Display
graceful Routing
Engine switchover
information for all
Routing Engines on all
members of the Virtual
Chassis configuration.
Display graceful
Routing Engines
switchover information
for all Routing Engines
on the local member of
the Virtual Chassis.
Display graceful Routing
Engine switchover
information for all
Routing Engines on the
specified member of
the Virtual Chassis.
show system uptime
Display the current
time and information
about how long the
router or switch, router
or switch software,
and routing protocols
have been running.
(Default) Show time
since the system
rebooted and
processes started on
all members of the
Virtual Chassis
configuration.
Show time since the
system rebooted and
processes started on
the local member of
the Virtual Chassis.
Show time since the
system rebooted and
processes started on
the specified member
of the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
55
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 13: Commands Available for Command Forwarding in an MX Series Virtual
Chassis (continued)
Command
Purpose
all-members
local
member member-id
show system users
List information about
the users who are
currently logged in to
the router.
(Default) Display users
currently logged in to
all members of the
Virtual Chassis
configuration.
Display users currently
logged in to the local
member of the Virtual
Chassis.
Display users currently
logged in to the
specified member of
the Virtual Chassis.
show system
virtual-memory
Display the usage of
Junos OS kernel
memory listed first by
size of allocation and
then by type of usage.
(Default) Display
kernel dynamic
memory usage
information for all
members of the Virtual
Chassis configuration.
Display kernel dynamic
memory usage
information for the
local member of the
Virtual Chassis.
Display kernel dynamic
memory usage
information for the
specified member of
the Virtual Chassis.
show version
Display the hostname
and version
information about the
software running on
the router.
(Default) Display
standard information
about the hostname
and version of the
software running on all
members of the Virtual
Chassis configuration.
Display standard
information about the
hostname and version
of the software running
on the local member of
the Virtual Chassis.
Display standard
information about the
hostname and version
of the software running
on the specified
member of the Virtual
Chassis.
show version invoke-on
Display the hostname
and version
information about the
software running on a
router with two
Routing Engines.
(Default) Display the
hostname and version
information about the
software running on all
master and backup
Routing Engines on all
members of the Virtual
Chassis configuration.
Display the hostname
and version
information about the
software running on all
master and backup
Routing Engines on the
local member of the
Virtual Chassis.
Display the hostname
and version information
about the software
running on all master
and backup Routing
Engines on the specified
member of the Virtual
Chassis.
Related
Documentation
56
•
Virtual Chassis Components Overview on page 24
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
CLI Explorer
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 3
Configuring a Virtual Chassis
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Preparing for a Virtual Chassis Configuration on page 60
•
Installing Junos OS Licenses on Virtual Chassis Member Routers on page 62
•
Creating and Applying Configuration Groups for a Virtual Chassis on page 64
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Configuring Enhanced IP Network Services for a Virtual Chassis on page 69
•
Enabling Graceful Routing Engine Switchover and Nonstop Active Routing for a Virtual
Chassis on page 70
•
Configuring Member IDs for a Virtual Chassis on page 72
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Configuring an MX2020 Member Router in an Existing MX Series Virtual
Chassis on page 92
•
Switching the Global Master and Backup Roles in a Virtual Chassis
Configuration on page 95
•
Deleting Member IDs in a Virtual Chassis Configuration on page 97
•
Disabling Split Detection in a Virtual Chassis Configuration on page 98
•
Example: Replacing a Routing Engine in a Virtual Chassis Configuration for MX Series
3D Universal Edge Routers on page 99
•
Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers on page 110
•
Example: Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers on page 111
•
Upgrading an MX Virtual Chassis SCB or SCBE to SCBE2 on page 123
Copyright © 2017, Juniper Networks, Inc.
57
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis
To provide a stateful interchassis redundancy solution for MX Series routers, you can
configure a Virtual Chassis. A Virtual Chassis interconnects two MX Series routers into a
logical system that you can manage as a single network element.
NOTE: For recommended settings on MX Virtual Chassis devices, please
consult Maximizing Scaling and Performance for MX Series Virtual Chassis on
the Juniper Networks Knowledge Base.
To configure a Virtual Chassis for MX Series routers:
1.
Prepare your site for the Virtual Chassis configuration.
See “Preparing for a Virtual Chassis Configuration” on page 60.
2. Install Junos OS licenses on the routers to be configured as members of the Virtual
Chassis.
See “Installing Junos OS Licenses on Virtual Chassis Member Routers” on page 62.
3. Define configuration groups for the Virtual Chassis.
See “Creating and Applying Configuration Groups for a Virtual Chassis” on page 64.
4. Create the preprovisioned member configuration on the master router in the Virtual
Chassis.
See “Configuring Preprovisioned Member Information for a Virtual Chassis” on page 66.
5. Configure enhanced IP network services on both member routers.
See “Configuring Enhanced IP Network Services for a Virtual Chassis” on page 69.
6. Enable graceful Routing Engine switchover (GRES) and nonstop active routing (NSR)
on both member routers.
See “Enabling Graceful Routing Engine Switchover and Nonstop Active Routing for a
Virtual Chassis” on page 70.
7. Set the preprovisioned member IDs and reboot the routers in Virtual Chassis mode.
See “Configuring Member IDs for a Virtual Chassis” on page 72.
8. Create the Virtual Chassis ports to interconnect the member routers, and commit the
Virtual Chassis configuration on the master router.
58
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
See “Configuring Virtual Chassis Ports to Interconnect Member Routers or Switches”
on page 136.
9. (Optional) Verify the configuration and operation of the Virtual Chassis.
See the following topics:
Related
Documentation
•
Verifying the Status of Virtual Chassis Member Routers or Switches on page 183
•
Verifying the Operation of Virtual Chassis Ports on page 183
•
Verifying Neighbor Reachability for Member Routers or Switches in a Virtual Chassis
on page 184
•
Verifying Neighbor Reachability for Hardware Devices in a Virtual Chassis on page 184
•
Viewing Information in the Virtual Chassis Control Protocol Adjacency Database
on page 186
•
Viewing Information in the Virtual Chassis Control Protocol Link-State Database
on page 187
•
Viewing Information About Virtual Chassis Port Interfaces in the Virtual Chassis
Control Protocol Database on page 188
•
Viewing Virtual Chassis Control Protocol Routing Tables on page 188
•
Viewing Virtual Chassis Control Protocol Statistics for Member Devices and Virtual
Chassis Ports on page 189
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Virtual Chassis Components Overview on page 24
•
Guidelines for Configuring Virtual Chassis Ports on page 134
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
59
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Preparing for a Virtual Chassis Configuration
Before you configure and use an MX Series Virtual Chassis, we recommend that you
prepare the hardware and software in your network for the configuration.
To prepare for configuring an MX Series Virtual Chassis:
1.
Make a list of the serial numbers of each router that you want to configure as part of
the Virtual Chassis.
The chassis serial number is located on a label affixed to the side of the of the MX
Series chassis. Alternatively, you can obtain the chassis serial number by issuing the
show chassis hardware command, which is especially useful if you are accessing the
router from a remote location. For example:
user@gladius> show chassis hardware
Hardware inventory:
Item
Version Part number
Chassis
.
.
.
Serial number
JN10C7135AFC
Description
MX240
2. Note the desired function of each router in the Virtual Chassis.
In a two-router Virtual Chassis configuration, you must designate each router with
the routing-engine role, which enables either router to function as the master or backup
of the Virtual Chassis.
NOTE: When configuring multiple Routing Engines in a Virtual Chassis,
all must have the same amount of physical memory allocated.
•
The master router maintains the global configuration and state information for all
members of the Virtual Chassis, and runs the chassis management processes.
•
The backup router synchronizes with the master router and relays chassis control
information (such as line-card presence and alarms) to the master router. If the
master router is unavailable, the backup router takes mastership of the Virtual
Chassis to preserve routing information and maintain network connectivity without
disruption.
3. Note the member ID (0 or 1) to be assigned to each router in the Virtual Chassis.
4. Ensure that both MX Series routers in the Virtual Chassis have dual Routing Engines
installed, and that all four Routing Engines in the Virtual Chassis are the same model.
For example, you cannot configure a Virtual Chassis if one member router has
RE-S-2000 Routing Engines installed and the other member router has RE-S-1800
Routing Engines installed.
For the list of supported Routing Engines on MX series routers, see Supported Routing
Engines by Router.
60
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
5. Ensure that the necessary Modular Port Concentrator/Modular Interface Card
(MPC/MIC) interfaces on which to configure the Virtual Chassis ports are installed
and operational in each router to be configured as a member of the Virtual Chassis.
NOTE: An MX Series Virtual Chassis does not support a combination of
1-Gigabit Ethernet (ge media type) Virtual Chassis ports and 10-Gigabit
Ethernet (xe media type) Virtual Chassis ports within the same Virtual
Chassis. You must configure either all 10-Gigabit Ethernet Virtual Chassis
ports or all 1-Gigabit Ethernet Virtual Chassis ports in the same Virtual
Chassis. We recommend that you configure Virtual Chassis ports on
10-Gigabit Ethernet interfaces. This restriction has no effect on access
ports or uplink ports in an MX Series Virtual Chassis configuration.
6. If MX Series Enhanced Queuing IP Services DPCs (DPCE-R-Q model numbers) or MX
Series Enhanced Queuing Ethernet Services DPCs (DPCE-X-Q model numbers) are
installed in a router to be configured as a member of the Virtual Chassis, make sure
these DPCs are offline before you configure the Virtual Chassis. Otherwise, the MX
Series Virtual Chassis configuration will not function.
NOTE: MX Series Enhanced Queuing IP Services DPCs (DPCE-R-Q model
numbers) and MX Series Enhanced Queuing Ethernet Services DPCs
(DPCE-X-Q model numbers) do not interoperate with features of the MX
Series Virtual Chassis.
7. Determine the desired location of the dedicated Virtual Chassis ports on both member
routers, and use the Virtual Chassis ports to physically interconnect the member
routers in a point-to-point topology.
8. Ensure that both MX Series routers to be configured as a member of the Virtual Chassis
are running the same Junos OS release, and have basic network connectivity.
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Guidelines for Configuring Virtual Chassis Ports on page 134
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
61
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Installing Junos OS Licenses on Virtual Chassis Member Routers
To enable some Junos OS features or router scaling levels, you might have to purchase,
install, and manage separate software license packs. The presence on the router of the
appropriate software license keys (passwords) determines whether you can configure
and use certain features or configure a feature to a predetermined scale.
Before you configure an MX Series Virtual Chassis, install the following Junos OS software
licenses on each MX Series router to be configured as a member of the Virtual Chassis:
•
MX Virtual Chassis Redundancy Feature Pack—You must purchase and install a unique
MX Virtual Chassis Redundancy Feature Pack for each member router in the Virtual
Chassis. If you issue the request virtual-chassis member-id set, request virtual-chassis
member-id delete, request virtual-chassis vc-port set, or request virtual-chassis vc-port
delete command to set or delete member IDs or Virtual Chassis ports without first
installing an MX Virtual Chassis Redundancy Feature Pack on both member routers,
the software displays a warning message that you are operating without a valid Virtual
Chassis software license.
•
Junos OS feature licenses—Purchase and install the appropriate Junos OS feature
licenses to enable use of a particular software feature or scaling level in your network.
You must install the required feature licenses on each member router in the Virtual
Chassis.
Before you begin:
•
Prepare your site for the Virtual Chassis configuration.
See “Preparing for a Virtual Chassis Configuration” on page 60.
•
Familiarize yourself with the procedures for installing and managing Junos OS licenses.
See Installation and Upgrade Guide.
To install Junos OS licenses on each member router in the Virtual Chassis:
1.
Install the required licenses on the MX Series router to be designated as the protocol
master for the Virtual Chassis.
a. Install the MX Virtual Chassis Redundancy Feature Pack.
b. Install the Junos OS feature licenses required for your software feature or scaling
level.
2. Install the required licenses on the MX Series router to be designated as the protocol
backup for the Virtual Chassis.
a. Install the MX Virtual Chassis Redundancy Feature Pack.
b. Install the Junos OS feature licenses required for your software feature or scaling
level.
3. (Optional) Verify the license installation on each member router.
62
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
For example:
user@host> show system license
License usage:
Feature name
subscriber-accounting
subscriber-authentication
subscriber-address-assignment
subscriber-vlan
subscriber-ip
scale-subscriber
scale-l2tp
scale-mobile-ip
virtual-chassis
Related
Documentation
Licenses
used
0
0
0
0
0
0
0
0
0
Licenses
installed
1
1
1
1
1
256000
1000
1000
1
Licenses
needed
0
0
0
0
0
0
0
0
0
Expiry
permanent
permanent
permanent
permanent
permanent
permanent
permanent
permanent
permanent
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Software Features That Require Licenses on MX Series Routers Only
•
Installation and Upgrade Guide
Copyright © 2017, Juniper Networks, Inc.
63
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Creating and Applying Configuration Groups for a Virtual Chassis
For a Virtual Chassis configuration consisting of two MX Series routers or two EX9200
switches, each of which supports dual Routing Engines, you must create and apply on
the master device of the Virtual Chassis the following configuration groups, instead of
using the standard re0 and re1 configuration groups:
•
member0-re0
•
member0-re1
•
member1-re0
•
member1-re1
NOTE: The membern-ren naming format for configuration groups is reserved
for exclusive use by member routers or switches in EX9200 or MX Series
Virtual Chassis configurations.
Using configuration group names of the form membern-ren in an existing
non-Virtual Chassis configuration or configuration script could interfere with
Virtual Chassis operation. This misconfiguration could cause the router or
switch to assign no IP address or an incorrect IP address to the fxp0
management Ethernet interface, and could result in a display of the Amnesiac
prompt during login.
To create and apply configuration group information from the router or switch to be
configured as the master of the Virtual Chassis:
1.
In the console window on the master router or switch (member 0 in this procedure),
create and apply the member0-re0 configuration group.
[edit]
user@host# copy groups re0 to member0-re0
user@host# set apply-groups member0-re0
2. Delete the standard re0 configuration group from the global configuration on member
0.
[edit]
user@host# delete apply-groups re0
user@host# delete groups re0
3. Create and apply the member0-re1 configuration group.
[edit]
user@host# copy groups re1 to member0-re1
user@host# set apply-groups member0-re1
64
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
4. Delete the standard re1 configuration group from the global configuration on member
0.
[edit]
user@host# delete apply-groups re1
user@host# delete groups re1
5. Create and apply the member1-re0 configuration information.
[edit]
user@host# set groups member1-re0 system host-name host-name
user@host# set groups member1-re0 system backup-router address
user@host# set groups member1-re0 system backup-router destination
destination-address
user@host# set groups member1-re0 system backup-router destination
destination-address
...
user@host# set groups member1-re0 interfaces fxp0 unit unit-number family inet
address address
user@host# set apply-groups member1-re0
The commands in Steps 5 and 6 set the IP address for the fxp0 management interface
and add an IP route for it in the event that routing becomes inactive.
6. Create and apply the member1-re1 configuration information.
[edit]
user@host# set groups member1-re1 system host-name host-name
user@host# set groups member1-re1 system backup-router address
user@host# set groups member1-re1 system backup-router destination
destination-address
user@host# set groups member1-re1 system backup-router destination
destination-address
...
user@host# set groups member1-re1 interfaces fxp0 unit unit-number family inet
address address
user@host# set apply-groups member1-re1
7. Commit the configuration.
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis.
For an EX9200 or MX Series Virtual Chassis, the force option is the default
and only behavior when you issue the commit synchronize command.
Issuing the commit synchronize command for a Virtual Chassis configuration
has the same effect as issuing the commit synchronize force command.
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
Copyright © 2017, Juniper Networks, Inc.
65
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
For more information about creating and managing configuration groups, see the Junos
OS CLI User Guide
Configuring Preprovisioned Member Information for a Virtual Chassis
To configure a Virtual Chassis for MX Series routers, you must create a preprovisioned
configuration on the master router by including the virtual-chassis stanza at the [edit
virtual-chassis] hierarchy level. The preprovisioned configuration specifies the chassis
serial number, member ID, and role for both member routers in the Virtual Chassis.
When a new member router joins the Virtual Chassis, the software compares its serial
number against the values specified in the preprovisioned configuration. If the serial
number of a joining router does not match any of the configured serial numbers, the
software prevents that router from becoming a member of the Virtual Chassis.
To configure the preprovisioned member information for an MX Series Virtual Chassis:
1.
Specify that you want to create a preprovisioned Virtual Chassis configuration.
[edit virtual-chassis]
user@host# set preprovisioned
2. Configure the member ID (0 or 1), role (routing-engine), and chassis serial number for
each member router in the Virtual Chassis.
[edit virtual-chassis]
user@host# set member member-number role routing-engine serial-number
serial-number
user@host# set member member-number role routing-engine serial-number
serial-number
NOTE: In a two-member MX Series Virtual Chassis configuration, you
must assign the routing-engine role to each router. The routing-engine role
enables the router to function either as the master router or backup router
of the Virtual Chassis.
3. Disable detection of a split in the Virtual Chassis configuration. (By default, split
detection in an MX Series Virtual Chassis is enabled.)
[edit virtual-chassis]
user@host# set no-split-detection
BEST PRACTICE: We recommend that you disable split detection for a
two-member MX Series Virtual Chassis configuration if you think the
66
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
backup router is more likely to fail than the Virtual Chassis port links to
the backup router. Configuring redundant Virtual Chassis ports on different
line cards in each member router reduces the likelihood that all Virtual
Chassis port links to the backup router will fail.
4. (Optional) Enable locality bias in the Virtual Chassis configuration.
[edit virtual-chassis]
user@host# set locality-bias
BEST PRACTICE: Starting in Junos OS Release 14.1, you can enable locality
bias in the Virtual Chassis configuration. Locality bias can cause traffic
loss and oversubscription on egress interfaces if you configure it in a
network that is not designed to handle locality biasing. Make sure you
understand the utilization requirements, such as total and available
bandwidth, for the local links in your network before changing the locality
bias configuration.
5. (Optional) Enable tracing of Virtual Chassis operations.
For example:
[edit virtual-chassis]
user@gladius# set traceoptions file filename
user@gladius# set traceoptions file size maximum-file-size
user@gladius# set traceoptions flag flag
6. Commit the configuration.
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis.
For an MX Series Virtual Chassis, the force option is the default and only
behavior when you issue the commit synchronize command. Issuing the
commit synchronize command for an MX Series Virtual Chassis
configuration has the same effect as issuing the commit synchronize force
command.
The following example shows an MX Series Virtual Chassis preprovisioned configuration
for two member routers.
[edit virtual-chassis]
user@gladius# show
preprovisioned;
no-split-detection;
locality-bias;
Copyright © 2017, Juniper Networks, Inc.
67
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
traceoptions {
file vccp size 10m;
flag all;
}
member 0 {
role routing-engine;
serial-number JN115FDADAFB;
}
member 1 {
role routing-engine;
serial-number JN10C78D1AFC;
}
Release History Table
Related
Documentation
68
Release
Description
14.1
Starting in Junos OS Release 14.1, you can enable locality bias in the Virtual
Chassis configuration.
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Configuring Enhanced IP Network Services for a Virtual Chassis
For an existing MX Series Virtual Chassis to function properly, you must configure
enhanced IP network services on all member routers in the Virtual Chassis from the Virtual
Chassis master router.
Enhanced IP network services defines how the chassis recognizes and uses certain
modules. When you set each member router’s network services to enhanced-ip, only
MPC/MIC modules and MS-DPC modules are powered on in the chassis. Non-service
DPCs do not work with enhanced IP network services.
This procedure describes how to configure enhanced IP network services for an existing
MX Series Virtual Chassis. For information about configuring enhanced IP network services
when you first set up the Virtual Chassis, see Configuring Enhanced IP Network Services
in “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75.
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis.
For an MX Series Virtual Chassis, the force option is the default and only
behavior when you issue the commit synchronize command. Issuing the commit
synchronize command for an MX Series Virtual Chassis configuration has the
same effect as issuing the commit synchronize force command.
To configure enhanced IP network services for an existing Virtual Chassis:
1.
Log in to the console for the master Routing Engine in the Virtual Chassis master router
(member0-re0 in this procedure).
2. Access the chassis hierarchy.
{master:member0-re0}[edit]
user@hostA# edit chassis
3. Configure enhanced IP network services on member 0.
{master:member0-re0}[edit chassis]
user@hostA# set network-services enhanced-ip
4. Commit the configuration.
5. When prompted to do so, reboot all Routing Engines in the Virtual Chassis.
{master:member0-re0}
user@hostA> request system reboot
Copyright © 2017, Juniper Networks, Inc.
69
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
The request system reboot command reboots both Routing Engines in each member
router forming the Virtual Chassis.
6. (Optional) Verify that enhanced IP network services has been properly configured for
the Virtual Chassis.
a. Verify that enhanced IP network services is configured on the master Routing Engine
in the Virtual Chassis master router (member0-re0).
{master:member0-re0}
user@hostA> show chassis network-services
Network Services Mode: Enhanced-IP
b. Verify that enhanced IP network services is configured on the master Routing Engine
in the Virtual Chassis backup router (member1-re0).
{backup:member1-re0}
user@hostB> show chassis network-services
Network Services Mode: Enhanced-IP
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Enabling Graceful Routing Engine Switchover and Nonstop Active Routing for a Virtual
Chassis
Before you configure member IDs and Virtual Chassis ports, you must enable graceful
Routing Engine switchover (GRES) and nonstop active routing (NSR) on both member
routers in the Virtual Chassis.
To enable graceful Routing Engine switchover and nonstop active routing:
1.
Enable graceful Routing Engine switchover and nonstop active routing on member 0
(gladius):
a. Log in to the console on member 0.
b. Enable graceful switchover.
[edit chassis redundancy]
user@gladius# set graceful-switchover
c. Enable nonstop active routing.
[edit routing-options]
user@gladius# set nonstop-routing
d. Configure the commit command to automatically result in a commit synchronize
action between the dual Routing Engines in member 0.
70
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
[edit system]
user@gladius# set commit synchronize
e. Commit the configuration.
2. Enable graceful Routing Engine switchover and nonstop active routing on member 1
(trefoil):
a. Log in to the console on member 1.
b. Enable graceful switchover.
[edit chassis redundancy]
user@trefoil# set graceful-switchover
c. Enable nonstop active routing.
[edit routing-options]
user@trefoil# set nonstop-routing
d. Configure the commit command to automatically result in a commit synchronize
action between the dual Routing Engines in member 1.
[edit system]
user@trefoil# set commit synchronize
e. Commit the configuration.
NOTE: When you configure nonstop active routing, you must include the
commit synchronize statement at the [edit system] hierarchy level.
Otherwise, the commit operation fails.
For an MX Series Virtual Chassis, the force option is the default and only
behavior when you use the commit synchronize statement. Including the
commit synchronize statement for an MX Series Virtual Chassis
configuration has the same effect as including the commit synchronize
force statement.
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Configuring Graceful Routing Engine Switchover
•
Configuring Nonstop Active Routing
Copyright © 2017, Juniper Networks, Inc.
71
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Configuring Member IDs for a Virtual Chassis
After you commit the preprovisioned configuration on the master router, you must assign
the preprovisioned member IDs to both MX Series routers in the Virtual Chassis by using
the request virtual-chassis member-id set command. In an MX Series Virtual Chassis, you
can optionally include the slots-per-chassis slot-count option to identify the number of
chassis slots in the member router. Assigning the member ID and, optionally, slot-count
causes the router to reboot in preparation for forming the Virtual Chassis.
NOTE: If you issue the request virtual-chassis member-id set command without
first installing an MX Virtual Chassis Redundancy Feature Pack license on
both member routers, the software displays a warning message that you are
operating without a valid Virtual Chassis software license.
For information about the supported member router combinations in an
MX Series Virtual Chassis, see “Interchassis Redundancy and Virtual Chassis
Overview” on page 19. Platform support depends on the Junos OS release in
your installation.
To configure the member ID and, optionally, slot count for each member router in an
MX Series Virtual Chassis:
72
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
1.
Set the member ID on the router configured as member 0 in one of the following ways:
•
For a Virtual Chassis consisting of a combination of MX240 routers, MX480 routers,
and MX960 routers:
user@hostA> request virtual-chassis member-id set member 0
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
With this Virtual Chassis configuration, the default slot-count (12) is the same for
both member routers, so you do not need to configure it.
•
For a Virtual Chassis consisting of an MX2010 router and either an MX960 router
or MX2010 router:
user@hostA> request virtual-chassis member-id set member 0
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
With this Virtual Chassis configuration, the default slot-count (12) is the same for
an MX960 router and an MX2010 router, so you do not need to configure it.
•
For a Virtual Chassis consisting of an MX2020 router and either an MX960 router
or MX2010 router:
user@hostA> request virtual-chassis member-id set member 0 slots-per-chassis
slot-count
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
To ensure that this Virtual Chassis configuration forms properly, you must set the
slot-count value of the MX960 router or MX2010 router to 20 to match the slot-count
of the MX2020 router. For example:
user@hostA> request virtual-chassis member-id set member 0 slots-per-chassis
20
•
For a Virtual Chassis consisting of two MX2020 routers:
user@hostA> request virtual-chassis member-id set member 0
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
With this Virtual Chassis configuration, the default slot-count (20) is the same for
both MX2020 routers, so you do not need to configure it.
The router reboots in preparation for forming the Virtual Chassis. After the reboot, all
MPCs remain powered off until the Virtual Chassis port connection is configured.
2. Repeat Step 1 to set the member ID on the router configured as member 1.
user@hostB> request virtual-chassis member-id set member 1
Copyright © 2017, Juniper Networks, Inc.
73
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
or
user@hostB> request virtual-chassis member-id set member 1 slots-per-chassis
slot-count
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
For example:
user@hostA> request virtual-chassis member-id set member 0 slots-per-chassis 20
The router reboots in preparation for forming the Virtual Chassis. After the reboot, all
MPCs remain powered off until the Virtual Chassis port connection is configured.
3. (Optional) Verify the member ID configuration for member 0.
For example:
{master:member0-re0}
user@hostA> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 4f2b.1aa0.de08
Mastership
List
Member ID
Interface
0 (FPC
Status
0- 11) Prsnt
Serial No
Model
JN10C7135AFC mx240
priority
129
Neighbor
Role
ID
Master*
4. (Optional) Verify the member ID configuration for member 1.
For example:
Amnesiac (ttyd0)
login: user
Password:
...
{master:member1-re0}
user> show virtual-chassis status
Virtual Chassis ID: ef98.2c6c.f7f7
Mastership
List
Member ID
Interface
1 (FPC
74
Status
12- 23) Prsnt
Serial No
Model
JN115D117AFB mx480
priority
128
Neighbor
Role
ID
Master*
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
NOTE: At this point in the configuration procedure, all line cards are offline,
and the routers are each designated with the Master role because they
are not yet interconnected as a fully formed Virtual Chassis. In addition,
member 1 remains in Amnesiac state (has no defined configuration) until
the Virtual Chassis forms and the configuration is committed.
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis
To provide interchassis redundancy for MX Series 3D Universal Edge Routers, you can
configure a Virtual Chassis. A Virtual Chassis configuration interconnects two MX Series
routers into a logical system that you can manage as a single network element. The
member routers in a Virtual Chassis are interconnected by means of Virtual Chassis ports
that you configure on Modular Port Concentrator/Modular Interface Card (MPC/MIC)
interfaces (network ports) on each MX Series router.
This example describes how to set up and configure a Virtual Chassis consisting of two
MX Series routers:
•
Requirements on page 75
•
Overview and Topology on page 76
•
Configuration on page 78
•
Verification on page 89
Requirements
This example uses the following software and hardware components:
•
Junos OS Release 11.2 and later releases
•
One MX240 3D Universal Edge Router
•
One MX480 3D Universal Edge Router
NOTE: This configuration example has been tested using the software release
listed and is assumed to work on all later releases.
Copyright © 2017, Juniper Networks, Inc.
75
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
See Table 14 on page 77 for information about the hardware installed in each MX Series
router.
BEST PRACTICE: We recommend that you use the commit synchronize
command throughout this procedure to save any configuration changes to
the Virtual Chassis.
For an MX Series Virtual Chassis, the force option is the default and only
behavior when you issue the commit synchronize command. Issuing the commit
synchronize command for an MX Series Virtual Chassis configuration has the
same effect as issuing the commit synchronize force command.
Overview and Topology
To configure the Virtual Chassis shown in this example, you must create a preprovisioned
configuration at the [edit virtual-chassis] hierarchy level on the router to be designated
as the master of the Virtual Chassis. The preprovisioned configuration includes the serial
number, member ID, and role for each member router (also known as member chassis)
in the Virtual Chassis. When a new member router joins the Virtual Chassis, the software
compares its serial number against the values specified in the preprovisioned
configuration. If the serial number of a joining router does not match any of the configured
serial numbers, the software prevents that router from becoming a member of the Virtual
Chassis.
After you commit the preprovisioned configuration on the master router, you must assign
the preprovisioned member IDs by issuing the request virtual-chassis member-id set
administrative command on each router, which causes the router to reboot. When the
reboot is complete, you create one or more Virtual Chassis ports by issuing the request
virtual-chassis vc-port set administrative command on each router. The Virtual Chassis
forms when the line cards in both member routers are back online.
This example configures a Virtual Chassis that interconnects two MX Series routers, and
uses the basic topology shown in Figure 2 on page 76. For redundancy, two Virtual Chassis
ports are configured on each member router.
Figure 2: Sample Topology for a Virtual Chassis with Two MX Series
Routers
76
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Table 14 on page 77 shows the hardware and software configuration settings for each
MX Series router in the Virtual Chassis. You use some of these settings in the
preprovisioned configuration and when you assign the member IDs and create the Virtual
Chassis ports.
NOTE: MX Series Enhanced Queuing IP Services DPCs (DPCE-R-Q model
numbers) and MX Series Enhanced Queuing Ethernet Services DPCs
(DPCE-X-Q model numbers) do not interoperate with features of the MX
Series Virtual Chassis. If any MX Series Enhanced Queuing DPCs are installed
in a router to be configured as a member of a Virtual Chassis, you must ensure
that these DPCs are offline before you configure the Virtual Chassis.
Table 14: Components of the Sample MX Series Virtual Chassis
Router
Name
Hardware
Serial
Number
Member
ID
gladius
MX240 router with:
JN10C7135AFC
0
•
60-Gigabit Ethernet
Enhanced Queuing
MPC
•
20-port Gigabit
Ethernet MIC with SFP
•
4-port 10-Gigabit
Ethernet MIC with XFP
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member0-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member0-re1)
Copyright © 2017, Juniper Networks, Inc.
Role
Virtual Chassis
Ports
Network Port
Slot Numbering
routing-engine
(master)
vcp-2/2/0
vcp-2/3/0
FPC 0 – 11
77
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 14: Components of the Sample MX Series Virtual Chassis (continued)
Router
Name
Hardware
Serial
Number
Member
ID
trefoil
MX480 router with:
JN115D117AFB
1
•
Two 30-Gigabit
Ethernet Queuing
MPCs
•
Two 20-port Gigabit
Ethernet MICs with
SFP
•
Two 2-port 10-Gigabit
Ethernet MICs with
XFP
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member1-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member1-re1)
Role
Virtual Chassis
Ports
Network Port
Slot Numbering
routing-engine
(backup)
vcp-2/0/0
vcp-5/2/0
FPC 12 – 23
(offset = 12)
Configuration
To configure a Virtual Chassis consisting of two MX Series routers, perform these tasks:
78
•
Preparing for the Virtual Chassis Configuration on page 79
•
Creating and Applying Configuration Groups for the Virtual Chassis on page 81
•
Configuring Preprovisioned Member Information for the Virtual Chassis on page 83
•
Configuring Enhanced IP Network Services on page 84
•
Enabling Graceful Routing Engine Switchover and Nonstop Active Routing on page 85
•
Configuring Member IDs and Rebooting the Routers to Enable Virtual Chassis
Mode on page 86
•
Configuring Virtual Chassis Ports to Interconnect Member Routers on page 88
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Preparing for the Virtual Chassis Configuration
Step-by-Step
Procedure
To prepare for configuring an MX Series Virtual Chassis:
1.
Make a list of the serial numbers of both routers that you want to configure as part
of the Virtual Chassis.
The chassis serial number is located on a label affixed to the side of the of the MX
Series chassis. Alternatively, you can obtain the chassis serial number by issuing
the show chassis hardware command, which is especially useful if you are accessing
the router from a remote location. For example:
user@gladius> show chassis hardware
Hardware inventory:
Item
Version Part number
Chassis
.
.
.
Fan Tray 0
REV 01
710-021113
2.
Serial number
JN10C7135AFC
Description
MX240
JT0119
MX240 Fan Tray
Note the desired role (routing-engine) for each router in the Virtual Chassis.
In a two-router Virtual Chassis configuration, you must designate each router with
the routing-engine role, which enables either router to function as the master or
backup of the Virtual Chassis.
3.
•
The master router maintains the global configuration and state information for
all members of the Virtual Chassis, and runs the chassis management processes.
•
The backup router synchronizes with the master router and relays chassis control
information (such as line-card presence and alarms) to the master router. If the
master router is unavailable, the backup router takes mastership of the Virtual
Chassis to preserve routing information and maintain network connectivity without
disruption.
Note the member ID (0 or 1) to be assigned to each router in the Virtual Chassis.
In this example, the master router is assigned member ID 0, and the backup router
is assigned member ID 1.
4.
Ensure that both MX Series routers in the Virtual Chassis have dual Routing Engines
installed, and that all four Routing Engines in the Virtual Chassis are the same model.
For example, you cannot configure a Virtual Chassis if one member router has
RE-S-2000 Routing Engines installed and the other member router has RE-S-1800
Routing Engines installed.
5.
Ensure that the necessary Modular Port Concentrator/Modular Interface Card
(MPC/MIC) interfaces on which to configure the Virtual Chassis ports are installed
and operational in each router to be configured as a member of the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
79
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
NOTE: An MX Series Virtual Chassis does not support a combination
of 1-Gigabit Ethernet (ge media type) Virtual Chassis ports and
10-Gigabit Ethernet (xe media type) Virtual Chassis ports within the
same Virtual Chassis. You must configure either all 10-Gigabit Ethernet
Virtual Chassis ports or all 1-Gigabit Ethernet Virtual Chassis ports in
the same Virtual Chassis. We recommend that you configure Virtual
Chassis ports on 10-Gigabit Ethernet interfaces. This restriction has no
effect on access ports or uplink ports in an MX Series Virtual Chassis
configuration.
6.
If MX Series Enhanced Queuing IP Services DPCs (DPCE-R-Q model numbers) or
MX Series Enhanced Queuing Ethernet Services DPCs (DPCE-X-Q model numbers)
are installed in a router to be configured as a member of the Virtual Chassis, make
sure these DPCs are offline before you configure the Virtual Chassis. Otherwise, the
MX Series Virtual Chassis configuration will not function.
NOTE: MX Series Enhanced Queuing IP Services DPCs (DPCE-R-Q
model numbers) and MX Series Enhanced Queuing Ethernet Services
DPCs (DPCE-X-Q model numbers) do not interoperate with features
of the MX Series Virtual Chassis.
80
7.
Determine the desired location of the dedicated Virtual Chassis ports on both
member routers, and use the Virtual Chassis ports to physically interconnect the
member routers in a point-to-point topology.
8.
Ensure that both MX Series routers to be configured as members of the Virtual
Chassis are running the same Junos OS release, and have basic network connectivity.
9.
Install the MX Virtual Chassis Redundancy Feature Pack license on each router to
be configured as part of the Virtual Chassis.
10.
Install the necessary Junos OS feature licenses on each router to be configured as
part of the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Creating and Applying Configuration Groups for the Virtual Chassis
Step-by-Step
Procedure
For a Virtual Chassis configuration consisting of two MX Series routers, each of which
supports dual Routing Engines, you must create and apply the following configuration
groups on the router to be designated as the master of the Virtual Chassis instead of
using the standard re0 and re1 configuration groups:
•
member0-re0
•
member0-re1
•
member1-re0
•
member1-re1
NOTE: The membern-ren naming format for configuration groups is reserved
for exclusive use by member routers in MX Series Virtual Chassis
configurations.
To create and apply configuration group information for the Virtual Chassis:
1.
Log in to the console on member 0 (gladius).
2.
In the console window on member 0, create and apply the member0-re0
configuration group.
[edit]
user@gladius# copy groups re0 to member0-re0
user@gladius# set apply-groups member0-re0
3.
Delete the standard re0 configuration group from the global configuration on
member 0.
[edit]
user@gladius# delete apply-groups re0
user@gladius# delete groups re0
4.
Create and apply the member0-re1 configuration group on member 0.
[edit]
user@gladius# copy groups re1 to member0-re1
user@gladius# set apply-groups member0-re1
5.
Delete the standard re1 configuration group from the global configuration on member
0.
[edit]
user@gladius# delete apply-groups re1
user@gladius# delete groups re1
Copyright © 2017, Juniper Networks, Inc.
81
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
6.
Create and apply the member1-re0 configuration information on member 0.
[edit]
user@gladius# set groups member1-re0 system host-name trefoil
user@gladius# set groups member1-re0 system backup-router 10.9.0.1
user@gladius# set groups member1-re0 system backup-router destination
172.16.0.0/12
user@gladius# set groups member1-re0 system backup-router destination
10.9.0.0/16
...
user@gladius# set groups member1-re0 interfaces fxp0 unit 0 family inet address
10.9.3.97/21
user@gladius# set apply-groups member1-re0
The examples in Steps 5 and 6 set the IP address for the fxp0 management interface
and add an IP route for it in the event that routing becomes inactive.
7.
Create and apply the member1-re1 configuration information on member 0.
[edit]
user@gladius# set groups member1-re1 system host-name trefoil
user@gladius# set groups member1-re1 system backup-router 10.9.0.1
user@gladius# set groups member1-re1 system backup-router destination
172.16.0.0/12
user@gladius# set groups member1-re1 system backup-router destination 10.9.0.0/16
...
user@gladius# set groups member1-re1 interfaces fxp0 unit 0 family inet address
10.9.3.98/21
user@gladius# set apply-groups member1-re1
8.
Results
Commit the configuration on member 0.
Display the results of the configuration.
[edit]
user@gladius# show groups ?
Possible completions:
<[Enter]>
<group_name>
global
member0-re0
member0-re1
member1-re0
member1-re1
|
Execute this command
Group name
Group name
Group name
Group name
Group name
Group name
Pipe through a command
[edit]
user@gladius# show apply-groups
apply-groups [ global member0-re0 member0-re1 member1-re0 member1-re1 ];
82
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Configuring Preprovisioned Member Information for the Virtual Chassis
Step-by-Step
Procedure
To configure the preprovisioned member information on member 0 (gladius):
1.
Log in to the console on member 0.
2.
Specify that you want to create a preprovisioned Virtual Chassis configuration.
[edit virtual-chassis]
user@gladius# set preprovisioned
3.
Configure the member ID (0 or 1), role (routing-engine), and chassis serial number
for each member router in the Virtual Chassis.
[edit virtual-chassis]
user@gladius# set member 0 role routing-engine serial-number JN10C7135AFC
user@gladius# set member 1 role routing-engine serial-number JN115D117AFB
4.
Disable detection of a split in the Virtual Chassis configuration. (By default, split
detection in an MX Series Virtual Chassis is enabled.)
[edit virtual-chassis]
user@gladius# set no-split-detection
BEST PRACTICE: We recommend that you disable split detection for a
two-member MX Series Virtual Chassis configuration if you think the
backup router is more likely to fail than the Virtual Chassis port links to
the backup router. Configuring redundant Virtual Chassis ports on
different line cards in each member router reduces the likelihood that
all Virtual Chassis port links to the backup router will fail.
5.
(Optional) Enable tracing of Virtual Chassis operations.
[edit virtual-chassis]
user@gladius# set traceoptions file vccp
user@gladius# set traceoptions file size 100m
user@gladius# set traceoptions flag all
6.
Results
Commit the configuration.
Display the results of the configuration.
[edit virtual-chassis]
user@gladius# show
preprovisioned;
no-split-detection;
traceoptions {
Copyright © 2017, Juniper Networks, Inc.
83
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
file vccp size 100m;
flag all;
}
member 0 {
role routing-engine;
serial-number JN10C7135AFC;
}
member 1 {
role routing-engine;
serial-number JN115D117AFB;
}
Configuring Enhanced IP Network Services
Step-by-Step
Procedure
For an MX Series Virtual Chassis to function properly, you must configure enhanced IP
network services on both member routers (member 0 and member 1). Enhanced IP
network services defines how the chassis recognizes and uses certain modules. When
you set each member router’s network services to enhanced-ip, only MPC/MIC modules
and MS-DPC modules are powered on in the chassis. Non-service DPCs do not work with
enhanced IP network services.
This procedure describes how to configure enhanced IP network services when you first
set up the Virtual Chassis. For information about configuring enhanced IP network services
for an existing MX Series Virtual Chassis, see “Configuring Enhanced IP Network Services
for a Virtual Chassis” on page 69.
To configure enhanced IP network services for a Virtual Chassis:
1.
Configure enhanced IP network services on member 0 (gladius).
a. Log in to the console on member 0.
b. Access the chassis hierarchy.
[edit]
user@gladius# edit chassis
c. Configure enhanced IP network services for member 0.
[edit chassis]
user@gladius# set network-services enhanced-ip
d. Commit the configuration on member 0.
NOTE: Immediately after you commit the configuration, the software
prompts you to reboot the router. You can proceed without rebooting
the router at this point because a reboot occurs when you configure
the member IDs to enable Virtual Chassis mode, later in this
procedure.
2.
84
Configure enhanced IP network services on member 1 (trefoil).
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
a. Log in to the console on member 1.
b. Access the chassis hierarchy.
[edit]
user@trefoil# edit chassis
c. Configure enhanced IP network services for member 1.
[edit chassis]
user@trefoil# set network-services enhanced-ip
d. Commit the configuration on member 1.
NOTE: Immediately after you commit the configuration, the software
prompts you to reboot the router. You can proceed without rebooting
the router at this point because a reboot occurs when you configure
the member IDs to enable Virtual Chassis mode, later in this
procedure.
Enabling Graceful Routing Engine Switchover and Nonstop Active Routing
Step-by-Step
Procedure
Before you configure member IDs and Virtual Chassis ports, you must enable graceful
Routing Engine switchover (GRES) and nonstop active routing (NSR) on both member
routers in the Virtual Chassis.
To enable graceful Routing Engine switchover and nonstop active routing:
1.
Enable graceful Routing Engine switchover and nonstop active routing on member
0 (gladius):
a. Log in to the console on member 0.
b. Enable graceful switchover.
[edit chassis redundancy]
user@gladius# set graceful-switchover
c. Enable nonstop active routing.
[edit routing-options]
user@gladius# set nonstop-routing
d. Configure the commit command to automatically result in a commit synchronize
action between the dual Routing Engines in member 0.
[edit system]
user@gladius# set commit synchronize
e. Commit the configuration.
2.
Enable graceful Routing Engine switchover and nonstop active routing on member
1 (trefoil):
Copyright © 2017, Juniper Networks, Inc.
85
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
a. Log in to the console on member 1.
b. Enable graceful switchover.
[edit chassis redundancy]
user@trefoil# set graceful-switchover
c. Enable nonstop active routing.
[edit routing-options]
user@trefoil# set nonstop-routing
d. Configure the commit command to automatically result in a commit synchronize
action between the dual Routing Engines in member 1.
[edit system]
user@trefoil# set commit synchronize
e. Commit the configuration.
NOTE: When you configure nonstop active routing, you must include
the commit synchronize statement at the [edit system] hierarchy level.
Otherwise, the commit operation fails.
For an MX Series Virtual Chassis, the force option is the default and only
behavior when you use the commit synchronize statement. Including the
commit synchronize statement for an MX Series Virtual Chassis
configuration has the same effect as including the commit synchronize
force statement.
Configuring Member IDs and Rebooting the Routers to Enable Virtual Chassis
Mode
Step-by-Step
Procedure
To configure (set) the preprovisioned member ID for each MX Series router in the Virtual
Chassis, use the request virtual-chassis member-id set command. Assigning the member
ID causes the router to reboot in preparation for forming the Virtual Chassis.
NOTE: If you issue the request virtual-chassis member-id set command without
first installing an MX Virtual Chassis Redundancy Feature Pack license on
both member routers, the software displays a warning message that you are
operating without a valid Virtual Chassis software license.
To configure the member ID and reboot each router to enable Virtual Chassis mode:
86
1.
Log in to the console on member 0 (gladius).
2.
Set the member ID on member 0.
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
user@gladius> request virtual-chassis member-id set member 0
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
Issuing the request virtual-chassis member-id command causes the router to reboot
in preparation for membership in the Virtual Chassis.
After the reboot, all MPCs remain powered off until the Virtual Chassis port
connection is configured.
3.
Log in to the console on member 1 (trefoil).
4.
Set the member ID on member 1.
user@trefoil> request virtual-chassis member-id set member 1
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
After the reboot, all MPCs remain powered off until the Virtual Chassis port
connection is configured.
Results
Display the results of the configuration on each router. At this point in the procedure, all
line cards are offline, and the routers are each designated with the Master role because
they are not yet interconnected as a fully formed Virtual Chassis. In addition, member 1
(trefoil) remains in Amnesiac state (has no defined configuration) until the Virtual Chassis
forms and the configuration is committed.
For member 0 (gladius):
{master:member0-re0}
user@gladius> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 4f2b.1aa0.de08
Mastership
Member ID
0 (FPC
Status
0- 11) Prsnt
Serial No
Model
JN10C7135AFC mx240
priority
129
Neighbor List
Role
ID
Interface
Master*
For member 1 (trefoil):
Amnesiac (ttyd0)
login: user
Password:
...
{master:member1-re0}
user> show virtual-chassis status
Copyright © 2017, Juniper Networks, Inc.
87
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Virtual Chassis ID: eabf.4e50.91e6
Virtual Chassis Mode: Disabled
Mastership
Member ID
1 (FPC
Status
12- 23) Prsnt
Serial No
Model
JN115D117AFB mx480
priority
128
Neighbor List
Role
ID
Interface
Master*
Configuring Virtual Chassis Ports to Interconnect Member Routers
Step-by-Step
Procedure
To interconnect the member routers in an MX Series Virtual Chassis, use the request
virtual-chassis vc-port set command to configure (set) Virtual Chassis ports on Modular
Port Concentrator/Modular Interface Card (MPC/MIC) interfaces.
NOTE: If you issue the request virtual-chassis vc-port set command without
first installing an MX Virtual Chassis Redundancy Feature Pack license on
both member routers, the software displays a warning message that you are
operating without a valid Virtual Chassis software license.
To configure Virtual Chassis ports on MPC/MIC interfaces to connect the member routers
in the Virtual Chassis:
1.
Configure the Virtual Chassis ports on member 0 (gladius).
a. Log in to the console on member 0.
b. Configure the first Virtual Chassis port that connects to member 1 (trefoil).
{master:member0-re0}
user@gladius> request virtual-chassis vc-port set fpc-slot 2 pic-slot 2 port 0
vc-port successfully set
After the Virtual Chassis port is created, it is renamed vcp-slot/pic/port (for
example, vcp-2/2/0), and the line card associated with that port comes online.
The line cards in the other member router remain offline until the Virtual Chassis
forms. Each Virtual Chassis port is dedicated to the task of interconnecting
member routers in a Virtual Chassis, and is no longer available for configuration
as a standard network port.
c. When vcp-2/2/0 is up, configure the second Virtual Chassis port that connects
to member 1.
{master:member0-re0}
user@gladius> request virtual-chassis vc-port set fpc-slot 2 pic-slot 3 port 0
vc-port successfully set
2.
Configure the Virtual Chassis ports on member 1 (trefoil).
a. Log in to the console on member 1.
b. Configure the first Virtual Chassis port that connects to member 0 (gladius).
88
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
{master:member1-re0}
user@trefoil> request virtual-chassis vc-port set fpc-slot 2 pic-slot 0 port 0
vc-port successfully set
c. When vcp-2/0/0 is up, configure the second Virtual Chassis port that connects
to member 0.
{master:member1-re0}
user@trefoil> request virtual-chassis vc-port set fpc-slot 5 pic-slot 2 port 0
vc-port successfully set
When all of the line cards in all of the member routers are online, and the Virtual
Chassis has formed, you can issue Virtual Chassis commands from the terminal
window of the master router (gladius).
3.
Verify that the Virtual Chassis is properly configured and operational.
{master:member0-re0}
user@gladius> show virtual-chassis status
{master:member0-re0}
user@gladius> show virtual-chassis vc-port all-members
See the Verification section for information about interpreting the output of these
commands.
4.
Commit the configuration on the master router.
The commit step is required to ensure that the configuration groups and Virtual
Chassis configuration are propagated to both members of the Virtual Chassis.
Verification
To confirm that the Virtual Chassis configuration is working properly, perform these tasks:
•
Verifying the Member IDs and Roles of the Virtual Chassis Members on page 89
•
Verifying the Enhanced IP Network Services Configuration on page 90
•
Verifying the Operation of the Virtual Chassis Ports on page 91
•
Verifying Neighbor Reachability on page 91
Verifying the Member IDs and Roles of the Virtual Chassis Members
Purpose
Verify that the member IDs and roles of the routers belonging to the Virtual Chassis are
properly configured.
Copyright © 2017, Juniper Networks, Inc.
89
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Action
Display the status of the members of the Virtual Chassis configuration:
{master:member0-re0}
user@gladius> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: a5b6.be0c.9525
Member ID
Meaning
Status
Serial No
Model
Mastership
priority
Role
Neighbor List
ID Interface
0 (FPC
0- 11) Prsnt
JN10C7135AFC mx240
129
Master*
1
1
vcp-2/2/0
vcp-2/3/0
1 (FPC
12- 23) Prsnt
JN115D117AFB mx480
129
Backup
0
0
vcp-2/0/0
vcp-5/2/0
The value Prsnt in the Status column of the output confirms that the member routers
specified in the preprovisioned configuration are currently connected to the Virtual Chassis.
The display shows that member 0 (gladius) and member 1 (trefoil), which were both
configured with the routing-engine role, are functioning as the master router and backup
router of the Virtual Chassis, respectively. The Neighbor List displays the interconnections
between the member routers by means of the Virtual Chassis ports. For example, member
0 is connected to member 1 through vcp-2/2/0 and vcp-2/3/0. The asterisk (*) following
Master denotes the router on which the command was issued. The Mastership priority
value is assigned by the software and is not configurable in the current release.
Verifying the Enhanced IP Network Services Configuration
Purpose
Action
Verify that enhanced IP network services has been properly configured for the Virtual
Chassis.
Display the setting of the network services configuration for the master Routing Engine
in the Virtual Chassis master router (member0-re0), and for the master Routing Engine
in the Virtual Chassis backup router (member1-re0).
{master:member0-re0}
user@gladius> show chassis network-services
Network Services Mode: Enhanced-IP
{backup:member1-re0}
user@trefoil> show chassis network-services
Network Services Mode: Enhanced-IP
Meaning
90
The output of the show chassis network services command confirms that enhanced IP
network services is properly configured on both member routers in the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Verifying the Operation of the Virtual Chassis Ports
Purpose
Action
Verify that the Virtual Chassis ports are properly configured and operational.
Display the status of the Virtual Chassis ports for both members of the Virtual Chassis.
{master:member0-re0}
user@gladius> show virtual-chassis vc-port all-members
member0:
-------------------------------------------------------------------------Interface
Type
Trunk Status
Speed
Neighbor
or
ID
(mbps)
ID Interface
Slot/PIC/Port
2/2/0
Configured
3
Up
10000
1
vcp-2/0/0
2/3/0
Configured
3
Up
10000
1
vcp-5/2/0
member1:
-------------------------------------------------------------------------Interface
Type
Trunk Status
Speed
Neighbor
or
ID
(mbps)
ID Interface
Slot/PIC/Port
2/0/0
Configured
3
Up
10000
0
vcp-2/2/0
5/2/0
Configured
3
Up
10000
0
vcp-2/3/0
Meaning
The output confirms that the Virtual Chassis ports you configured are operational. For
each member router, the Interface or Slot/PIC/Port column shows the location of the
Virtual Chassis ports configured on that router. For example, the Virtual Chassis ports on
member0-re0 (gladius) are vcp-2/2/0 and vcp-2/3/0. In the Trunk ID column, the value
3 indicates that a trunk has formed; if a trunk is not present, this field displays the value
-1 . In the Status column, the value Up confirms that the interfaces associated with the
Virtual Chassis ports are operational. The Speed column displays the speed of the Virtual
Chassis port interface. The Neighbor ID/Interface column displays the member IDs and
Virtual Chassis port interfaces that connect to this router. For example, the connections
to member 0 (gladius) are through vcp-2/0/0 and vcp-5/2/0 on member 1 (trefoil).
Verifying Neighbor Reachability
Purpose
Verify that each member router in the Virtual Chassis can reach the neighbor routers to
which it is connected.
Copyright © 2017, Juniper Networks, Inc.
91
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Action
Display the neighbor reachability information for both member routers in the Virtual
Chassis.
{master:member0-re0}
user@gladius> show virtual-chassis active-topology all-members
member0:
-------------------------------------------------------------------------Destination ID
Next-hop
1
1(vcp-2/2/0.32768)
member1:
-------------------------------------------------------------------------Destination ID
Next-hop
0
Meaning
Related
Documentation
0(vcp-2/0/0.32768)
The output confirms that each member router in the Virtual Chassis has a path to reach
the neighbors to which it is connected. For each member router, the Destination ID specifies
the member ID of the destination (neighbor) router. The Next-hop column displays the
member ID and Virtual Chassis port interface of the next-hop to which packets for the
destination ID are forwarded. For example, the next-hop from member 0 (gladius) to
member 1 (trefoil) is through Virtual Chassis port interface vcp-2/2/0.32768.
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Virtual Chassis Components Overview on page 24
•
Guidelines for Configuring Virtual Chassis Ports on page 134
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
Configuring an MX2020 Member Router in an Existing MX Series Virtual Chassis
Starting in Junos OS Release 15.1, in an existing two-member MX Series Virtual Chassis
that includes an MX960 router or an MX2010 router, you can replace one or both of these
routers with an MX2020 router. If you replace either the MX960 router or MX2010 router
with an MX2020 router, you must follow this procedure to ensure that the new Virtual
Chassis forms properly and that any configurations you use reflect the correct Flexible
PIC Concentrator (FPC) slot numbering for interfaces configured on the MX2020 member
router.
Before you begin:
•
92
Ensure that the existing Virtual Chassis is properly configured and operational before
replacing one of the member routers with an MX2020 router.
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
See “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75.
•
Make sure you know the member router combinations supported with an MX2020
router.
See “Interchassis Redundancy and Virtual Chassis Overview” on page 19.
•
Make sure you understand the slot count values for MX960, MX2010, and MX2020
member routers, and how the FPC slots are numbered when you configure a Virtual
Chassis with an MX2020 router.
See “Virtual Chassis Components Overview” on page 24.
To configure an MX2020 member router in an existing MX Series Virtual Chassis with
either an MX960 router or an MX2010 router:
1.
Replace either the MX960 router or MX2010 router with an MX2020 router.
Install the interface modules in the same physical slots in the MX2020 router as they
were when installed in the MX960 or MX2010 router.
2. Upgrade all four Routing Engines in the Virtual Chassis (two Routing Engines in each
member router) to the current Junos OS software release.
NOTE: All four Routing Engines in the Virtual Chassis must be the same
model and running the same Junos OS software release. For a Virtual
Chassis that includes an MX2020 router, all four Routing Engines must
have at least 16 gigabytes of memory.
3. Set the member ID and slot count of the MX960 router or MX2010 router.
To ensure that a Virtual Chassis configuration with an MX2020 router and either an
MX960 router or MX2010 router forms properly, you must set the slot-count value of
the MX960 router or MX2010 router to 20 to match the slot-count of the MX2020
router.
user@hostA> request virtual-chassis member-id set member member-id
slots-per-chassis slot-count
For example, assume that the MX960 router or MX2010 router is member 1 in the
preprovisioned Virtual Chassis configuration. To set the member ID and slot count for
member 1:
user@hostA> request virtual-chassis member-id set member 1 slots-per-chassis 20
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
The router reboots in preparation for forming the Virtual Chassis. After the reboot, the
FPC slots are renumbered and all MPCs remain powered off until the Virtual Chassis
port connection is configured.
Copyright © 2017, Juniper Networks, Inc.
93
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
4. Edit your Junos OS configuration to rename any interfaces configured on member 1
to reflect how the FPC slots are renumbered when the Virtual Chassis includes an
MX2020 member router.
Before you add the MX2020 router to the Virtual Chassis, member 0 uses FPC slot
numbers 0 through 11 with no offset, and member 1 uses slot numbers 12 through 23
with an offset of 20. After you set the slot count of the MX960 or MX2010 router to
20 and reboot the MX2020 member router, member 0 uses slot numbers 0 through
19 with no offset, and member 1 uses slot numbers 20 through 39 with an offset of
20.
For example, in the following partial configuration, ge-0/0/0 is an aggregated Ethernet
link configured on FPC slot 0 in member 0, and ge-12/0/0 is an aggregated Ethernet
link configured on FPC slot 0 in member 1.
[edit]
interfaces {
ge-0/0/0 {
gigether-options {
802.3ad ae0;
}
}
ge-12/0/0 {
gigether-options {
802.3ad ae0;
}
}
ae0 {
...
...
}
}
If you replace member 1 with an MX2020 member router, FPC slot 0 in member 1 is
renumbered as FPC slot 20 on member 1. As a result, you must edit the configuration
to change ge-12/0/0 to ge-20/0/0, as follows:
[edit]
interfaces {
ge-0/0/0 {
gigether-options {
802.3ad ae0;
}
}
ge-20/0/0 {
gigether-options {
802.3ad ae0;
}
}
ae0 {
...
...
}
}
94
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Release History Table
Related
Documentation
Release
Description
15.1
Starting in Junos OS Release 15.1, in an existing two-member MX Series Virtual
Chassis that includes an MX960 router or an MX2010 router, you can replace
one or both of these routers with an MX2020 router.
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Configuring Member IDs for a Virtual Chassis on page 72
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Virtual Chassis Components Overview on page 24
Switching the Global Master and Backup Roles in a Virtual Chassis Configuration
You can change the mastership in an MX Series Virtual Chassis by switching the global
roles of the master router and backup router in the Virtual Chassis configuration. When
you change the mastership by issuing the request virtual-chassis routing-engine master
switch administrative command, the current master router in the Virtual Chassis (also
known as the Virtual Chassis protocol master, or VC-M) becomes the backup router, and
the current backup router (also known as the Virtual Chassis protocol backup, or VC-B)
becomes the master router.
Before you begin:
•
Make sure the system configuration is synchronized between the master router and
the backup router.
If the configuration between the member routers is not synchronized when you issue
the request virtual-chassis routing-engine master switch command, the router displays
the following error message and rejects the command.
Error: mastership switch request NOT honored, backup not ready
•
Make sure the Virtual Chassis is not in a transition state (for example, the backup router
is in the process of disconnecting from the Virtual Chassis) when you issue the request
virtual-chassis routing-engine master switch command.
If you attempt to issue the request virtual-chassis routing-engine master switch
command during a transition state, the router does not process the command.
To switch the global master and backup roles:
•
Issue the request virtual-chassis routing-engine master switch command from the Virtual
Chassis master Routing Engine in the Virtual Chassis master router (VC-Mm):
{master:member0-re0}
user@host> request virtual-chassis routing-engine master switch
Do you want to continue ? [yes,no] (no) yes
Copyright © 2017, Juniper Networks, Inc.
95
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
If you attempt to issue the request virtual-chassis routing-engine master switch
command from the backup router , the router displays the following error message
and rejects the command.
error: Virtual Chassis member is not the protocol master
Issuing the request virtual-chassis routing-engine master switch command from the
VC-Mm causes the global role transitions listed in Table 15 on page 96.
Table 15: Virtual Chassis Global Role Transitions Before and After
Mastership Switchover
Related
Documentation
96
Virtual Chassis Role Before Switching
Mastership
Virtual Chassis Role After Switching
Mastership
Master Routing Engine in Virtual Chassis
master router (VC-Mm)
Standby Routing Engine in Virtual Chassis backup
router (VC-Bs)
Standby Routing Engine in Virtual Chassis
master router (VC-Ms)
Master Routing Engine in Virtual Chassis backup
router (VC-Bm)
Master Routing Engine in Virtual Chassis
backup router (VC-Bm)
Master Routing Engine in Virtual Chassis master
router (VC-Mm)
Standby Routing Engine in Virtual Chassis
backup router (VC-Bs)
Standby Routing Engine in Virtual Chassis master
router (VC-Ms)
•
Switchover Behavior in an MX Series Virtual Chassis on page 34
•
Virtual Chassis Components Overview on page 24
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Mastership Election in a Virtual Chassis on page 32
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Deleting Member IDs in a Virtual Chassis Configuration
In most cases, you delete the member ID from a member router or switch as part of the
procedure for deleting a Virtual Chassis configuration. When you delete the member ID
by using the request virtual-chassis member-id delete command, the router or switch
reboots and the software disables Virtual Chassis mode on that device. After the reboot,
the router or switch is no longer part of the Virtual Chassis and functions as an independent
device.
NOTE: If you issue the request virtual-chassis member-id delete command
without first installing an MX Virtual Chassis Redundancy Feature Pack license
on both member routers, the software displays a warning message that you
are operating without a valid Virtual Chassis software license.
A software license is not needed to create an EX9200 Virtual Chassis.
To delete the Virtual Chassis member IDs from both member routers or switches and
disable Virtual Chassis mode:
1.
In the console window on the router or switch configured as member 0, delete member
ID 0.
{master:member0-re0}
user@host1> request virtual-chassis member-id delete
This command will disable virtual-chassis mode and reboot the system.
Continue? [yes,no] (no) yes
Updating VC configuration and rebooting system, please wait...
{master:member0-re0}
user@host1>
*** FINAL System shutdown message from root@host1 ***
System going down IMMEDIATELY
2. In the console window on the router or switch configured as member 1, delete member
ID 1.
{master:member1-re0}
user@host2> request virtual-chassis member-id delete
This command will disable virtual-chassis mode and reboot the system.
Continue? [yes,no] (no) yes
Updating VC configuration and rebooting system, please wait...
{master:member1-re0}
user@host2>
*** FINAL System shutdown message from root@host2 ***
System going down IMMEDIATELY
Copyright © 2017, Juniper Networks, Inc.
97
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
3. (Optional) Confirm that Virtual Chassis mode has been disabled on both member
routers or switches.
For example:
user@host1> show virtual-chassis status
error: the virtual-chassis-control subsystem is not running
Related
Documentation
•
Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge Routers on
page 110
•
Configuring an EX9200 Virtual Chassis
•
Example: Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers on page 111
Disabling Split Detection in a Virtual Chassis Configuration
If there is a disruption to a Virtual Chassis due to failure of a member device or one or
more Virtual Chassis port links, the resulting connectivity loss can cause a split in the
Virtual Chassis configuration. Split detection, which is enabled by default in an MX Series
and EX9200 Virtual Chassis, identifies the split and minimizes further network disruption.
You can disable split detection by including the no-split-detection statement at the [edit
virtual-chassis] hierarchy level. Disabling split detection can be useful in certain Virtual
Chassis configurations.
For example, if the backup device fails in a two-member Virtual Chassis configuration
and split detection is enabled (the default behavior), the master device takes a line-card
role, and the line cards (FPCs) that do not host Virtual Chassis ports go offline. This state
effectively isolates the master router or switch and removes it from the Virtual Chassis
until connectivity is restored. As a result, routing or switching is halted and the Virtual
Chassis configuration is disabled. By contrast, if the backup router or switch fails in a
two-member Virtual Chassis configuration and split detection is disabled, the master
router or switch retains mastership and maintains all of the Virtual Chassis ports,
effectively resulting in a single-member Virtual Chassis consisting of only the master
device.
BEST PRACTICE: We recommend that you disable split detection for a
two-member Virtual Chassis configuration if you think the backup router or
switch is more likely to fail than the Virtual Chassis port interfaces to the
backup router or switch. Configuring redundant Virtual Chassis ports on
different line cards in each member router or switch reduces the likelihood
that all Virtual Chassis port interfaces to the backup router or switch can fail.
To disable split detection:
1.
98
Specify that you want to disable the default detection of splits in the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
[edit virtual-chassis]
user@host# set no-split-detection
2. Commit the configuration.
Disabling split detection causes different results for different types of Virtual Chassis
failures. For information, see “Split Detection Behavior in a Virtual Chassis” on page 38.
Related
Documentation
•
Split Detection Behavior in a Virtual Chassis on page 38
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Switchover Behavior in an MX Series Virtual Chassis on page 34
•
Virtual Chassis Components Overview on page 24
Example: Replacing a Routing Engine in a Virtual Chassis Configuration for MX Series
3D Universal Edge Routers
If you remove a Routing Engine from a member router in an MX Series Virtual Chassis for
upgrade or repair, you must replace it with a new Routing Engine in the empty Routing
Engine slot, and install the same Junos OS release on the new Routing Engine that is
running on the other Routing Engines in the Virtual Chassis. The Virtual Chassis remains
operational during the replacement procedure.
All four Routing Engines (both Routing Engines in the master router and both Routing
Engines in the backup router) in the Virtual Chassis must run the same Junos OS release.
BEST PRACTICE: We recommend that you replace a Routing Engine in an
MX Series Virtual Chassis configuration during a maintenance window to
minimize the possibility of disruption to subscribers.
This example describes how to replace a Routing Engine in an MX Series Virtual Chassis
configuration consisting of two MX Series routers, each of which has dual Routing Engines
installed:
•
Requirements on page 99
•
Overview and Topology on page 100
•
Configuration on page 102
•
Verification on page 106
Requirements
This example uses the following software and hardware components:
•
Junos OS Release 11.4 and later releases
•
One MX240 3D Universal Edge Router with dual Routing Engines
Copyright © 2017, Juniper Networks, Inc.
99
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
One MX480 3D Universal Edge Router with dual Routing Engines
NOTE: This configuration example has been tested using the software release
listed and is assumed to work on all later releases.
See Table 16 on page 101 for information about the hardware installed in each MX Series
router.
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis.
For an MX Series Virtual Chassis, the force option is the default and only
behavior when you issue the commit synchronize command. Issuing the commit
synchronize command for an MX Series Virtual Chassis configuration has the
same effect as issuing the commit synchronize force command.
Overview and Topology
To replace a Routing Engine in an MX Series Virtual Chassis configuration, you must:
1.
Remove the Routing Engine that needs repair or upgrade.
2. Return the Routing Engine to Juniper Networks, Inc.
3. Install the new Routing Engine in the empty Routing Engine slot.
4. Modify the Routing Engine factory configuration to enable formation of the Virtual
Chassis.
5. Install the same Junos OS release on the new Routing Engine that is running on the
other Routing Engines in the Virtual Chassis.
6. Reboot the new Routing Engine to run the Junos OS software release.
Figure 3 on page 101 shows the topology of the MX Series Virtual Chassis configuration
used in this example. This example replaces the backup RE-S-2000 Routing Engine in
slot 1 of the Virtual Chassis backup router, which is an MX480 router named trefoil that
is assigned member ID 1. The backup Routing Engine in slot 1 of trefoil is represented in
the example as member1-re1.
For redundancy, each of the two member routers is configured with two Virtual Chassis
ports.
100
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Figure 3: Sample Topology for a Virtual Chassis with Two MX Series
Routers
Virtual Chassis
gladius
MX240
member 0
Active
Standby
Access Node
vcp-2/3/0
vcp-2/0/0
vcp-5/2/0
Active
Core
trefoil
MX480
member 1
Standby
Access Node
Service
Provider
Network
g017471
Subscribers
Core
vcp-2/2/0
Table 16 on page 101 shows the hardware and software configuration settings for each
MX Series router in the Virtual Chassis.
Table 16: Components of the Sample MX Series Virtual Chassis
Router
Name
Hardware
Serial
Number
Member
ID
gladius
MX240 router with:
JN10C7135AFC
0
•
60-Gigabit Ethernet
Enhanced Queuing
MPC
•
20-port Gigabit
Ethernet MIC with SFP
•
4-port 10-Gigabit
Ethernet MIC with XFP
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member0-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member0-re1)
Copyright © 2017, Juniper Networks, Inc.
Role
Virtual Chassis
Ports
Network Port
Slot Numbering
routing-engine
(master)
vcp-2/2/0
vcp-2/3/0
FPC 0 – 11
101
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 16: Components of the Sample MX Series Virtual Chassis (continued)
Router
Name
Hardware
Serial
Number
Member
ID
trefoil
MX480 router with:
JN115D117AFB
1
•
Two 30-Gigabit
Ethernet Queuing
MPCs
•
Two 20-port Gigabit
Ethernet MICs with
SFP
•
Two 2-port 10-Gigabit
Ethernet MICs with
XFP
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member1-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member1-re1)
Role
Virtual Chassis
Ports
Network Port
Slot Numbering
routing-engine
(backup)
vcp-2/0/0
vcp-5/2/0
FPC 12 – 23
(offset = 12)
Configuration
To replace a Routing Engine in a Virtual Chassis configuration consisting of two MX Series
routers, each with dual Routing Engines, perform these tasks:
102
•
Removing the Routing Engine on page 103
•
Returning the Routing Engine to Juniper Networks, Inc. on page 103
•
Installing the New Routing Engine on page 103
•
Modifying the Routing Engine Factory Configuration on page 103
•
Installing the Junos OS Release on the New Routing Engine on page 105
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Removing the Routing Engine
Step-by-Step
Procedure
To remove the Routing Engine that needs repair or upgrade:
•
Remove the Routing Engine according to the procedure for your MX Series router.
•
For an MX240 router, see Removing an MX240 Routing Engine in the MX240 3D
Universal Edge Router Hardware Guide.
•
For an MX480 router, see Removing an MX480 Routing Engine in the MX480 3D
Universal Edge Router Hardware Guide.
•
For an MX960 router, see Removing an MX960 Routing Engine in the MX960 3D
Universal Edge Router Hardware Guide.
Returning the Routing Engine to Juniper Networks, Inc.
Step-by-Step
Procedure
To return the Routing Engine to Juniper Networks, Inc:
•
Obtain a Return Materials Authorization (RMA) from the Juniper Networks Technical
Assistance Center (JTAC) and return the Routing Engine to Juniper Networks, Inc.
For instructions, see Returning a Hardware Component to Juniper Networks, Inc. in
the Hardware Guide for your MX Series router.
Installing the New Routing Engine
Step-by-Step
Procedure
To install the new Routing Engine in the Virtual Chassis member router:
•
Install the Routing Engine in the empty Routing Engine slot of the member router
according to the procedure for your MX Series router.
•
For an MX240 router, see Installing an MX240 Routing Engine in the MX240 3D
Universal Edge Router Hardware Guide.
•
For an MX480 router, see Installing an MX480 Routing Engine in the MX480 3D
Universal Edge Router Hardware Guide.
•
For an MX960 router, see Installing an MX960 Routing Engine in the MX960 3D
Universal Edge Router Hardware Guide.
Modifying the Routing Engine Factory Configuration
Step-by-Step
Procedure
Copyright © 2017, Juniper Networks, Inc.
103
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
A Routing Engine shipped from the factory is loaded with a default factory configuration
that includes the following stanza at the [edit] hierarchy level:
[edit]
system {
commit {
factory-settings {
reset-virtual-chassis-configuration;
}
}
}
When this configuration stanza is present, the Routing Engine can operate only in a
standalone chassis and not in a Virtual Chassis member router. As a result, if you install
this Routing Engine in the standby slot of a Virtual Chassis member router (member1-re1
in this procedure), the Routing Engine does not automatically synchronize with the master
Routing Engine and boot in Virtual Chassis mode.
To ensure that the standby factory Routing Engine successfully synchronizes with the
master Routing Engine, you must remove the standalone chassis configuration stanza
from the standby factory Routing Engine and verify that it reboots in Virtual Chassis mode
before you install the Junos OS release.
To modify the Routing Engine factory configuration to ensure proper operation of the
Virtual Chassis:
1.
Log in to the console of the new Routing Engine as the user root with no password.
2.
Configure a plain-text password for the root (superuser) login.
{local:member1-re1}[edit system]
root# set root-authentication plain-text-password
New password: type password here
Retype new password: retype password here
3.
Delete the standalone chassis configuration.
{local:member1-re1}[edit]
root# delete system commit factory-settings reset-virtual-chassis-configuration
4.
Commit the configuration.
The new Routing Engine synchronizes the Virtual Chassis member ID with the master
Routing Engine and boots in Virtual Chassis mode.
5.
Verify that the new Routing Engine is in Virtual Chassis mode.
During the boot process, the router displays the following output to indicate that it
has synchronized the Virtual Chassis member ID (1) with the master Routing Engine
and is in Virtual Chassis mode.
...
virtual chassis member-id = 1
104
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
virtual chassis mode
= 1
...
Installing the Junos OS Release on the New Routing Engine
Step-by-Step
Procedure
You must install the same Junos OS release on the new Routing Engine that is running
on the other Routing Engines in the MX Series Virtual Chassis. Installing the Junos OS
software prepares the Routing Engine to run the new Junos OS release after a reboot.
This action is also referred to as arming the Routing Engine.
To install the Junos OS release on the new Routing Engine (member1-re1) in the Virtual
Chassis:
1.
Use FTP or a Web browser to download the Junos OS software to the master Routing
Engine on the Virtual Chassis master router (member0-re0).
See Downloading Software in the Installation and Upgrade Guide.
NOTE: Make sure you download and install the same Junos OS release
that is running on all Routing Engines in the Virtual Chassis.
2.
If you have not already done so, log in to the console of the new Routing Engine as
the user root with no password.
3.
If you have not already done so, configure a plain-text password for the root
(superuser) login.
{local:member1-re1}[edit system]
root# set root-authentication plain-text-password
New password: type password here
Retype new password: retype password here
4.
Log in to the console of the Virtual Chassis master router (member0-re0) as the
user root.
5.
From the console of the Virtual Chassis master router, commit the configuration.
{master:member0-re0}[edit]
root# commit synchronize and-quit
...
member1-re0:
configuration check succeeds
member0-re0:
commit complete
member1-re0:
commit complete
member1-re1:
commit complete
Copyright © 2017, Juniper Networks, Inc.
105
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Exiting configuration mode
6.
Use Telnet or SSH to log in to the member router containing the new Routing Engine
(trefoil).
{local:member1-re1}
user@trefoil>
Notice that the router name (trefoil) now appears in the command prompt.
7.
Install the Junos OS release on the new Routing Engine (member1-re1) from the
Virtual Chassis master router (member0-re0).
{master:member0-re0}
user@trefoil> request system software add member member-id re1 no-validate reboot
package-name force
For example:
{master:member0-re0}
user@trefoil> request system software add member 1 re1 no-validate reboot
/var/tmp/jinstall-11.4R1-8-domestic-signed.tgz force
Pushing bundle to re1...
This command reboots member1-re1 after the software is added.
Results
After the reboot, the new Routing Engine becomes part of the Virtual Chassis, updates
its command prompt to display member1-re1, and copies the appropriate configuration
from the Virtual Chassis.
Verification
To verify that the MX Series Virtual Chassis is operating properly with the new Routing
Engine, perform these tasks:
•
Verifying the Junos OS Installation on the New Routing Engine on page 106
•
Verifying the Junos OS License Installation on the New Routing Engine on page 107
•
Switching the Local Mastership in the Member Router to the New Routing
Engine on page 108
Verifying the Junos OS Installation on the New Routing Engine
Purpose
106
Verify that you have installed the correct Junos OS release on the new Routing Engine
(member1-re1).
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Action
Display the hostname, model name, and version information of the Junos OS release
running on the new Routing Engine.
{local:member1-re1}
user@trefoil> show version local
Hostname: trefoil
Model: mx480
. . .
JUNOS Base OS boot [11.4R1-8]
JUNOS Base OS Software Suite [11.4R1-8]
. . .
Meaning
The relevant portion of the show version local command output confirms that Junos OS
Release 11.4R1-8 was installed as intended.
Verifying the Junos OS License Installation on the New Routing Engine
Purpose
Verify that the MX Virtual Chassis Redundancy Feature Pack and the required Junos OS
feature licenses are properly installed on the member router containing the new Routing
Engine.
For information about license installation, see:
Action
•
Installing Junos OS Licenses on Virtual Chassis Member Routers on page 62
•
Software Features That Require Licenses on MX Series Routers Only
Display the Junos OS licenses installed on the new Routing Engine.
{local:member1-re1}
user@trefoil> show system license
License usage:
Feature name
subscriber-accounting
subscriber-authentication
subscriber-address-assignment
subscriber-vlan
subscriber-ip
scale-subscriber
scale-l2tp
scale-mobile-ip
virtual-chassis
Meaning
Licenses
used
0
0
0
0
0
0
0
0
0
Licenses
installed
1
1
1
1
1
256000
1000
1000
1
Licenses
needed
0
0
0
0
0
0
0
0
0
Expiry
permanent
permanent
permanent
permanent
permanent
permanent
permanent
permanent
permanent
The show system license command output confirms that the MX Virtual Chassis
Redundancy Feature Pack has been installed on this member router. In addition, the
necessary Junos OS feature licenses have been installed to enable use of a particular
software feature or scaling level.
Copyright © 2017, Juniper Networks, Inc.
107
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Switching the Local Mastership in the Member Router to the New Routing Engine
Purpose
Action
Verify that the MX Series Virtual Chassis is operating properly with the new Routing Engine
by confirming that the new Routing Engine can take over local mastership from the
existing Routing Engine in the Virtual Chassis backup router, trefoil (member 1).
Switch the local mastership of the Routing Engines in trefoil from the Routing Engine in
slot 0 (member1-re0) to the newly installed Routing Engine in slot 1 (member1-re1).
{backup:member1-re0}
user@trefoil> request chassis routing-engine master switch
Wait approximately 1 minute to display the status and roles of the member routers in the
Virtual Chassis after the local switchover.
{backup:member1-re1}
user@trefoil> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: a5b6.be0c.9525
Member ID
Meaning
Status
Serial No
Model
Mastership
priority
Role
Neighbor List
ID Interface
0 (FPC
0- 11) Prsnt
JN10C7135AFC mx240
129
Master
1
1
vcp-2/2/0
vcp-2/3/0
1 (FPC
12- 23) Prsnt
JN115D117AFB mx480
129
Backup*
0
0
vcp-2/0/0
vcp-5/2/0
Issuing the request chassis routing-engine master switch command to initiate the local
switchover of the Routing Engines in the Virtual Chassis backup router (trefoil) affects
only the roles of the Routing Engines in that member router (member1-re0 and
member1-re1), but does not change the global mastership of the Virtual Chassis. The
output of the show virtual-chassis status command confirms that after the local
switchover, member 0 (gladius) is still the Virtual Chassis master router, and member 1
(trefoil) is still the Virtual Chassis backup router.
Before the local switchover, member1-re0 was the master Routing Engine in the Virtual
Chassis backup router (VC-Bm), and member1-re1 (the new Routing Engine) was the
standby Routing Engine in the Virtual Chassis backup router (VC-Bs).
After the local switchover, member1-re0 and member1-re1 switch roles. The new Routing
Engine, member1-re1, becomes the master Routing Engine in the Virtual Chassis backup
router (VC-Bm), and member1-re0 becomes the standby Routing Engine in the Virtual
Chassis backup router (VC-Bs).
Table 17 on page 109 lists the role transitions that occur for each member router and
Routing Engine before and after the local switchover of the Routing Engines in trefoil.
108
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
NOTE: The role transitions described in Table 17 on page 109 apply only when
you initiate the local switchover from the Virtual Chassis backup router
(VC-B). For information about the role transitions that occur when you initiate
the local switchover from the Virtual Chassis master router (VC-M), see
“Switchover Behavior in an MX Series Virtual Chassis” on page 34.
Table 17: Virtual Chassis Role Transitions Before and After Local Routing
Engine Switchover
Role Before Local
Switchover
Role After Local
Switchover
gladius (member 0)
Virtual Chassis master router
(VC-M)
Virtual Chassis master router
(VC-M)
trefoil (member 1)
Virtual Chassis backup router
(VC-B)
Virtual Chassis backup router
(VC-B)
member0-re0
Master Routing Engine in the
Virtual Chassis master router
(VC-Mm)
Master Routing Engine in the
Virtual Chassis master router
(VC-Mm)
member0-re1
Standby Routing Engine in the
Virtual Chassis master router
(VC-Ms)
Standby Routing Engine in
the Virtual Chassis master
router (VC-Ms)
member1-re0
Master Routing Engine in the
Virtual Chassis backup router
(VC-Bm)
Standby Routing Engine in
the Virtual Chassis backup
router (VC-Bs)
member1-re1 (new Routing
Standby Routing Engine in the
Virtual Chassis backup router
(VC-Bs)
Master Routing Engine in the
Virtual Chassis backup router
(VC-Bm)
Virtual Chassis Component
Engine)
BEST PRACTICE: After you switch the local mastership of the Routing Engines,
full synchronization of the Routing Engines takes approximately 30 minutes
to complete. To prevent possible loss of subscriber state information due to
incomplete synchronization, we recommend that you wait at least 30 minutes
before performing another local switchover, global switchover, or graceful
Routing Engine switchover in an MX Series Virtual Chassis configuration.
Related
Documentation
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Virtual Chassis Components Overview on page 24
•
Installing Junos OS Licenses on Virtual Chassis Member Routers on page 62
Copyright © 2017, Juniper Networks, Inc.
109
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
Switchover Behavior in an MX Series Virtual Chassis on page 34
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Installation and Upgrade Guide
Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge Routers
You can delete an MX Series Virtual Chassis configuration at any time. You might want
to do so if your network configuration changes, or if you want to replace one or both MX
Series member routers with different MX Series routers.
To delete a Virtual Chassis configuration for MX Series routers:
1.
Delete the Virtual Chassis ports from each member router.
See “Deleting Virtual Chassis Ports in a Virtual Chassis Configuration” on page 138.
2. Delete the definitions and applications for the following configuration groups on each
member router:
•
member0-re0
•
member0-re1
•
member1-re0
•
member1-re1
3. Delete the preprovisioned member information configured at the [edit virtual-chassis]
hierarchy level on the master router.
4. Delete any interfaces that were configured on the member routers when the Virtual
Chassis was created.
5. Delete the Virtual Chassis member IDs to reboot each router and disable Virtual
Chassis mode.
See “Deleting Member IDs in a Virtual Chassis Configuration” on page 97.
NOTE: You cannot override a Virtual Chassis configuration simply by using
the load override command to load a different configuration on the router
from an ASCII file or from terminal input, as you can with other configurations.
The member ID and Virtual Chassis port definitions are not stored in the
configuration file, and are still defined even after the new configuration file
is loaded.
110
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Related
Documentation
•
Example: Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers on page 111
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Virtual Chassis Components Overview on page 24
Example: Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers
You can delete an MX Series Virtual Chassis configuration at any time. You might want
to do so if your network configuration changes, or if you want to replace one or both MX
Series member routers in the Virtual Chassis with different MX Series routers. After you
delete the Virtual Chassis configuration, the routers that were formerly members of the
Virtual Chassis function as two independent routers.
This example describes how to delete a Virtual Chassis configuration consisting of two
MX Series routers:
•
Requirements on page 111
•
Overview and Topology on page 112
•
Configuration on page 114
•
Verification on page 121
Requirements
This example uses the following software and hardware components:
•
Junos OS Release 11.2 and later releases
•
One MX240 3D Universal Edge Router with dual Routing Engines
•
One MX480 3D Universal Edge Router with dual Routing Engines
NOTE: This configuration example has been tested using the software release
listed and is assumed to work on all later releases.
SeeTable 18 on page 113 for information about the hardware installed in each MX Series
router.
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis.
For an MX Series Virtual Chassis, the force option is the default and only
behavior when you issue the commit synchronize command. Issuing the commit
synchronize command for an MX Series Virtual Chassis configuration has the
same effect as issuing the commit synchronize force command.
Copyright © 2017, Juniper Networks, Inc.
111
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Overview and Topology
To delete an MX Series Virtual Chassis configuration, you must:
1.
Delete all Virtual Chassis ports.
2. Remove the definitions and applications of the Virtual Chassis configuration groups.
3. Delete the preprovisioned member information configured at the [edit virtual-chassis]
hierarchy level.
4. Delete any configured interfaces.
5. Remove the member IDs of each member router.
After you issue the request virtual-chassis member-id delete command on each router to
remove the member ID, the router reboots and the software disables Virtual Chassis
mode on that router.
Because the entire Virtual Chassis configuration is propagated from the master router
to the other member router when the Virtual Chassis forms, you must delete each
component of the Virtual Chassis configuration from both member routers, even though
the component was originally configured only on the master router. For example, even
though the preprovisioned member information was configured at the [edit virtual-chassis]
hierarchy level only on the master router, you must delete the virtual-chassis stanza from
the other member router in the Virtual Chassis.
NOTE: When deleting the Virtual Chassis, you must also delete all Virtual
Chassis-related configuration details from all stanzas, otherwise errors will
result upon commit.
NOTE: You cannot override a Virtual Chassis configuration simply by using
the load override command to load a different configuration on the router
from an ASCII file or from terminal input, as you can with other configurations.
The member ID and Virtual Chassis port definitions are not stored in the
configuration file, and are still defined even after the new configuration file
is loaded.
This example deletes the Virtual Chassis configuration that uses the basic topology
shown in Figure 4 on page 113. For redundancy, each member router is configured with
two Virtual Chassis ports, both of which must be removed as part of the deletion process.
112
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Figure 4: Sample Topology for a Virtual Chassis with Two MX Series
Routers
Virtual Chassis
gladius
MX240
member 0
Active
Standby
Access Node
vcp-2/3/0
vcp-2/0/0
vcp-5/2/0
Active
Core
trefoil
MX480
member 1
Standby
Access Node
Service
Provider
Network
g017471
Subscribers
Core
vcp-2/2/0
Table 18 on page 113 shows the hardware and software configuration settings for each
MX Series router in the Virtual Chassis.
Table 18: Components of the Sample MX Series Virtual Chassis
Router
Name
Hardware
Serial
Number
Member
ID
gladius
MX240 router with:
JN10C7135AFC
0
•
60-Gigabit Ethernet
Enhanced Queuing
MPC
•
20-port Gigabit
Ethernet MIC with SFP
•
4-port 10-Gigabit
Ethernet MIC with XFP
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member0-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member0-re1)
Copyright © 2017, Juniper Networks, Inc.
Role
Virtual Chassis
Ports
Network Port
Slot Numbering
routing-engine
(master)
vcp-2/2/0
vcp-2/3/0
FPC 0 – 11
113
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 18: Components of the Sample MX Series Virtual Chassis (continued)
Router
Name
Hardware
Serial
Number
Member
ID
trefoil
MX480 router with:
JN115D117AFB
1
•
Two 30-Gigabit
Ethernet Queuing
MPCs
•
Two 20-port Gigabit
Ethernet MICs with
SFP
•
Two 2-port 10-Gigabit
Ethernet MICs with
XFP
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member1-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member1-re1)
Role
Virtual Chassis
Ports
Network Port
Slot Numbering
routing-engine
(backup)
vcp-2/0/0
vcp-5/2/0
FPC 12 – 23
(offset = 12)
Configuration
To delete a Virtual Chassis configuration consisting of two MX Series routers, perform
these tasks:
114
•
Deleting Virtual Chassis Ports on page 115
•
Deleting Configuration Group Definitions and Applications on page 116
•
Deleting Preprovisioned Member Information on page 118
•
Deleting Configured Interfaces on page 119
•
Deleting Member IDs to Disable Virtual Chassis Mode on page 120
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Deleting Virtual Chassis Ports
Step-by-Step
Procedure
To delete a Virtual Chassis port from a member router, you must use the request
virtual-chassis vc-port delete command.
NOTE: If you issue the request virtual-chassis vc-port delete command without
first installing an MX Virtual Chassis Redundancy Feature Pack license on
both member routers, the software displays a warning message that you are
operating without a valid Virtual Chassis software license.
To remove the Virtual Chassis ports from each member router:
1.
In the console window on member 0 (gladius), remove both Virtual Chassis ports
(vcp-2/2/0 and vcp-2/3/0).
{master:member0-re0}
user@gladius> request virtual-chassis vc-port delete fpc-slot 2 pic-slot 2 port 0
vc-port successfully deleted
{master:member0-re0}
user@gladius> request virtual-chassis vc-port delete fpc-slot 2 pic-slot 3 port 0
vc-port successfully deleted
2.
In the console window on member 1 (trefoil), remove both Virtual Chassis ports
(vcp-2/0/0 and vcp-5/2/0).
{backup:member1-re0}
user@trefoil> request virtual-chassis vc-port delete fpc-slot 2 pic-slot 0 port 0
vc-port successfully deleted
{backup:member1-re0}
user@trefoil> request virtual-chassis vc-port delete fpc-slot 5 pic-slot 2 port 0
vc-port successfully deleted
Results
Display the results of the Virtual Chassis port deletion on each router. Confirm that no
Virtual Chassis ports are listed in the output of either the show virtual-chassis status
command or the show virtual-chassis vc-port command.
{master:member0-re0}
user@gladius> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 4d6f.54cd.d2c1
Mastership
Member ID
0 (FPC
Copyright © 2017, Juniper Networks, Inc.
Status
0- 11) Prsnt
Serial No
Model
JN10C7135AFC mx240
priority
129
Neighbor List
Role
ID
Interface
Master*
115
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
1 (FPC
12- 23) NotPrsnt JN115D117AFB mx480
{master:member0-re0}
user@gladius> show virtual-chassis vc-port
member0:
--------------------------------------------------------------------------
TIP: Deleting and then re-creating a Virtual Chassis port in an MX Series
Virtual Chassis configuration may cause the Virtual Chassis port to appear
as Absent in the Status column of the show virtual-chassis vc-port command
display. To resolve this issue, reboot the FPC that hosts the re-created Virtual
Chassis port.
Deleting Configuration Group Definitions and Applications
Step-by-Step
Procedure
As part of deleting a Virtual Chassis configuration for MX Series routers with dual Routing
Engines, you must delete the definitions and applications for the following configuration
groups on both member routers:
•
member0-re0
•
member0-re1
•
member1-re0
•
member1-re1
To retain the information in these configuration groups before you delete them, you must
copy them to the standard re0 and re1 configuration groups on the router, as described
in the following procedure. For example, copy configuration groups member0-re0 and
member1-re0 to re0, and copy member0-re1 and member1-re1 to re1.
NOTE: The membern-ren naming format for configuration groups is reserved
for exclusive use by member routers in MX Series Virtual Chassis
configurations.
To delete the configuration group definitions and applications for an MX Series Virtual
Chassis:
1.
116
In the console window on member 0 (gladius), delete the Virtual Chassis
configuration group definitions and applications.
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
a. Copy the Virtual Chassis configuration groups to the standard configuration
groups re0 and re1.
{master:member0-re0}[edit]
user@gladius# copy groups member0-re0 to re0
user@gladius# copy groups member0-re1 to re1
b. Apply the re0 and re1 configuration groups.
{master:member0-re0}[edit]
user@gladius# set apply-groups re0
user@gladius# set apply-groups re1
c. Delete the Virtual Chassis configuration group definitions.
{master:member0-re0}[edit]
user@gladius# delete groups member0-re0
user@gladius# delete groups member0-re1
user@gladius# delete groups member1-re0
user@gladius# delete groups member1-re1
d. Delete the Virtual Chassis configuration group applications.
{master:member0-re0}[edit]
user@gladius# delete apply-groups member0-re0
user@gladius# delete apply-groups member0-re1
user@gladius# delete apply-groups member1-re0
user@gladius# delete apply-groups member1-re1
2.
In the console window on member 1 (trefoil), delete the Virtual Chassis configuration
group definitions and applications.
a. Copy the Virtual Chassis configuration groups to the standard configuration
groups re0 and re1.
{backup:member1-re0}[edit]
user@trefoil# copy groups member1-re0 to re0
user@trefoil# copy groups member1-re1 to re1
b. Apply the re0 and re1 configuration groups.
{backup:member1-re0}[edit]
user@trefoil# set apply-groups re0
user@trefoil# set apply-groups re1
c. Delete the Virtual Chassis configuration group definitions.
{backup:member1-re0}[edit]
user@trefoil# delete groups member0-re0
user@trefoil# delete groups member0-re1
user@trefoil# delete groups member1-re0
user@trefoil# delete groups member1-re1
d. Delete the Virtual Chassis configuration group applications.
{backup:member1-re0}[edit]
user@trefoil# delete apply-groups member0-re0
user@trefoil# delete apply-groups member0-re1
user@trefoil# delete apply-groups member1-re0
user@trefoil# delete apply-groups member1-re1
Copyright © 2017, Juniper Networks, Inc.
117
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Results
Display the results of the configuration. Confirm that configuration groups member0-re0,
member 0-re1, member1-re0, and member1-re1 do not appear in the output of either the
show groups command or the show apply-groups command.
[edit]
user@gladius# show groups ?
Possible completions:
<[Enter]>
<group_name>
global
re0
re1
|
Execute this command
Group name
Group name
Group name
Group name
Pipe through a command
[edit]
user@gladius# show apply-groups
## Last changed: 2010-12-01 09:17:27 PST
apply-groups [ global re0 re1 ];
Deleting Preprovisioned Member Information
Step-by-Step
Procedure
You must delete the preprovisioned member information, which was configured at the
[edit virtual-chassis] hierararchy level on the master router and then propagated to the
backup router during the formation of the Virtual Chassis.
To delete the preprovisioned member information for the Virtual Chassis:
1.
Delete the virtual-chassis configuration stanza on member 0 (gladius).
{master:member0-re0}[edit]
user@gladius# delete virtual-chassis
2.
Delete the virtual-chassis configuration stanza on member 1 (trefoil).
{backup:member1-re0}[edit]
user@trefoil# delete virtual-chassis
Results
Display the results of the deletion. Confirm that the virtual-chassis stanza no longer exists
on either member router. For example, on gladius (member 0):
{master:member0-re0}[edit]
user@gladius# show virtual-chassis
<no output>
118
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Deleting Configured Interfaces
Step-by-Step
Procedure
As part of deleting the Virtual Chassis, we recommend that you delete any interfaces
that were configured when the Virtual Chassis was formed. This action ensures that
nonexistent interfaces or interfaces belonging to the other member router do not remain
on the router after Virtual Chassis mode is disabled.
To delete any interfaces that you configured when creating the Virtual Chassis:
1.
In the console window on member 0 (gladius), delete any configured interfaces
and commit the configuration.
a. Delete the configured interfaces.
{master:member0-re0}[edit]
user@gladius# delete interfaces
b. Commit the configuration on member 0.
{master:member0-re0}[edit system]
user@gladius# commit synchronize
member0-re0:
configuration check succeeds
member0-re1:
commit complete
member0-re0:
commit complete
2.
In the console window on member 1 (trefoil), delete any configured interfaces and
commit the configuration.
a. Delete the configured interfaces.
{backup:member1-re0}[edit]
user@trefoil# delete interfaces
b. Commit the configuration on member 1.
{backup:member1-re0}[edit system]
user@trefoil# commit synchronize
member1-re0:
configuration check succeeds
member1-re1:
commit complete
member1-re0:
commit complete
Copyright © 2017, Juniper Networks, Inc.
119
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Deleting Member IDs to Disable Virtual Chassis Mode
Step-by-Step
Procedure
To delete a member ID from a Virtual Chassis member router, you must use the request
virtual-chassis member-id delete command.
NOTE: If you issue the request virtual-chassis member-id delete command
without first installing an MX Virtual Chassis Redundancy Feature Pack license
on both member routers, the software displays a warning message that you
are operating without a valid Virtual Chassis software license.
To delete the Virtual Chassis member IDs and disable Virtual Chassis mode:
1.
In the console window on member 0 (gladius), delete the member ID and reboot
the router.
a. Exit configuration mode.
{master:member0-re0}[edit]
user@gladius# exit
Exiting configuration mode
b. Delete member ID 0.
{master:member0-re0}
user@gladius> request virtual-chassis member-id delete
This command will disable virtual-chassis mode and reboot the system.
Continue? [yes,no] (no) yes
Updating VC configuration and rebooting system, please wait...
{master:member0-re0}
user@gladius>
*** FINAL System shutdown message from root@gladius ***
System going down IMMEDIATELY
2.
In the console window on member 1 (trefoil), delete the member ID and reboot the
router.
a. Exit configuration mode.
{master:member1-re0}[edit]
user@trefoil# exit
Exiting configuration mode
b. Delete member ID 1.
{master:member1-re0}
user@trefoil> request virtual-chassis member-id delete
This command will disable virtual-chassis mode and reboot the system.
Continue? [yes,no] (no) yes
120
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Updating VC configuration and rebooting system, please wait...
{backup:member1-re0}
user@trefoil>
*** FINAL System shutdown message from root@trefoil ***
System going down IMMEDIATELY
Results
After you issue the request virtual-chassis member-id delete command to remove the
member ID, the router reboots and the software disables Virtual Chassis mode on that
router. The routers that were formerly members of the Virtual Chassis now function as
two independent routers.
Display the results of the configuration to confirm that the Virtual Chassis configuration
has been deleted on each router. For example, on gladius (formerly member 0):
user@gladius> show virtual-chassis status
error: the virtual-chassis-control subsystem is not running
user@gladius> show virtual-chassis vc-port
error: the virtual-chassis-control subsystem is not running
Verification
To confirm that the Virtual Chassis configuration has been properly deleted, perform
these tasks:
•
Verifying Deletion of the Virtual Chassis Ports on page 121
•
Verifying Deletion of the Virtual Chassis Configuration Groups on page 122
•
Verifying Deletion of the Virtual Chassis Member IDs on page 123
Verifying Deletion of the Virtual Chassis Ports
Purpose
Action
Verify that the Virtual Chassis ports on both member routers have been deleted from
the configuration.
Display the status of the Virtual Chassis configuration and Virtual Chassis ports.
{master:member0-re0}
user@gladius> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 4d6f.54cd.d2c1
Mastership
Member ID
0 (FPC
Copyright © 2017, Juniper Networks, Inc.
Status
0- 11) Prsnt
Serial No
Model
JN10C7135AFC mx240
priority
129
Neighbor List
Role
ID
Interface
Master*
121
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
1 (FPC
12- 23) NotPrsnt JN115D117AFB mx480
{master:member0-re0}
user@gladius> show virtual-chassis vc-port
member0:
--------------------------------------------------------------------------
Meaning
In the output of the show virtual-chassis status command, no Virtual Chassis ports
(vcp-slot/pic/port) are displayed in the Neighbor List. The asterisk (*) following Master
denotes the router on which the show virtual-chassis status command command was
issued.
In the output of the show virtual-chassis vc-port command, no Virtual Chassis ports are
displayed on the router on which the command was issued.
Verifying Deletion of the Virtual Chassis Configuration Groups
Purpose
Action
Verify that the definitions and applications of the following Virtual Chassis configuration
groups have been deleted from the global configuration:
•
member0-re0
•
member0-re1
•
member1-re0
•
member1-re1
Display the status of the Virtual Chassis configuration group definitions and applications.
[edit]
user@gladius# show groups ?
Possible completions:
<[Enter]>
<group_name>
global
re0
re1
|
Execute this command
Group name
Group name
Group name
Group name
Pipe through a command
[edit]
user@gladius# show apply-groups
apply-groups [ global re0 re1 ];
Meaning
122
The output confirms that the Virtual Chassis configuration group definitions and
applications have been deleted. In the output of both show groups and show apply-groups,
only the standard configuration groups (global, re0, and re1) are listed. The Virtual Chassis
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
configuration groups (member0-re0, member 0-re1, member1-re0, and member1-re1) do
not appear.
Verifying Deletion of the Virtual Chassis Member IDs
Purpose
Action
Verify that the member IDs for the Virtual Chassis have been deleted, and that the Virtual
Chassis is no longer configured on either MX Series router.
Display the results of the configuration on each router. For example, on trefoil (formerly
member 1):
user@trefoil> show virtual-chassis status
error: the virtual-chassis-control subsystem is not running
user@trefoil> show virtual-chassis vc-port
error: the virtual-chassis-control subsystem is not running
Meaning
Related
Documentation
When you attempt to issue either the show virtual-chassis status command or the show
virtual-chassis vc-port command after the Virtual Chassis has been deleted, the router
displays an error message indicating that the Virtual Chassis is no longer configured, and
rejects the command.
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Virtual Chassis Components Overview on page 24
•
Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge Routers on
page 110
Upgrading an MX Virtual Chassis SCB or SCBE to SCBE2
To upgrade an MX Virtual Chassis SCB or SCBE to SCBE2, perform the following steps:
NOTE: SCBE2 does not support smooth upgrade.
1.
Preparing for the SCBE2 Upgrade on page 124
2. Powering Off the MX Series Router on page 124
3. Removing an MX Series Routing Engine from an SCB or SCBE on page 125
4. Replacing the SCB or SCBE with SCBE2 on page 125
5. Installing the MX Series Routing Engine into an SCBE2 on page 126
6. Powering On the MX Series Router on page 126
7. Configuring Member IDs for the Virtual Chassis on page 127
Copyright © 2017, Juniper Networks, Inc.
123
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
8. Configuring Virtual Chassis Ports on page 129
9. Completing the SCBE2 Upgrade on page 130
Preparing for the SCBE2 Upgrade
To prepare for the SCBE2 upgrade:
1.
Verify that the system is runing Junos OS Release 13.3 or later by issuing the show
version command on the master router.
user@host> show version
Junos Base OS Software Suite [13.3-yyyymmdd];
...
NOTE: The SCBE2 is supported only on:
•
Junos OS Release 13.3 or later
•
Network Services Mode: Enhanced-IP
The latest software ensures a healthy system—that is, a system that comprises Routing
Engines, control boards, and FPCs—before the upgrade.
For information about how to verify and upgrade Junos OS on MX Virtual Chassis
configurations, see “Example: Upgrading Junos OS in a Virtual Chassis Configuration
for MX Series 3D Universal Edge Routers by Rebooting the Routing Engines” on page 165.
2. Record the local IP address of each RE in the Virtual Chassis configuration. This
information will be necessary to reconfigure the VC member IDs after the upgrade.
3. Apply a system halt before shutting down the system by issuing the request system
halt all-members command on the master router.
user@host> request system halt all-members
Powering Off the MX Series Router
NOTE: After turning off the power supply, wait at least 60 seconds before
turning it back on.
124
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
To power off the MX Series router:
1.
On the external management device connected to the Routing Engine, issue the
request system halt all-members operational mode command. The command shuts
down the Routing Engines cleanly, so that their state information is preserved.
user@host> request system halt all-members
2. Wait until a message appears on the console confirming that the operating system
has halted.
3. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect
the strap to one of the ESD points on the chassis.
4. Move the AC input switch on the chassis above the AC power supply or the DC circuit
breaker on each DC power supply faceplate to the off (O) position.
Removing an MX Series Routing Engine from an SCB or SCBE
To remove an MX Series Routing Engine from an SCB or SCBE:
Remove the Routing Engine according to the procedure for your MX Series router.
•
For an MX240 router, see Removing an MX240 Routing Engine in the MX240 3D Universal
Edge Router Hardware Guide.
•
For an MX480 router, see Removing an MX480 Routing Engine in the MX480 3D Universal
Edge Router Hardware Guide.
•
For an MX960 router, see Removing an MX960 Routing Engine in the MX960 3D Universal
Edge Router Hardware Guide.
Replacing the SCB or SCBE with SCBE2
To replace the existing SCB or SCBE with SCBE2:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect
the strap to one of the ESD points on the chassis.
2. Remove and replace the offline SCB or SCBE on the router with SCBE2.
Copyright © 2017, Juniper Networks, Inc.
125
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Installing the MX Series Routing Engine into an SCBE2
After removing the routing engine from the original SCB or SCBE, you can install it into
the new SCBE2. Follow these instructions to install a MX Series Routing Engine into an
SCBE2:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.
2. Ensure that the ejector handles are not in the locked position. If necessary, flip the
ejector handles outward.
3. Place one hand underneath the Routing Engine to support it.
4. Carefully align the sides of the Routing Engine with the guides inside the opening on
the SCBE2.
5. Slide the Routing Engine into the SCBE2 until you feel resistance and then press the
faceplate of the Routing Engine until it engages the connectors.
6. Press both of the ejector handles inward to seat the Routing Engine.
7. Tighten the captive screws on the top and bottom of the Routing Engine.
8. Connect the management device cables to the Routing Engine.
Powering On the MX Series Router
To power on the MX Series router:
1.
Verify that the power supplies are fully inserted in the chassis.
2. Verify that each AC power cord is securely inserted into its appliance inlet.
3. Verify that an external management device is connected to one of the Routing Engine
ports (AUX, CONSOLE, or ETHERNET).
4. Turn on the power to the external management device.
5. Switch on the dedicated customer-site circuit breakers. Follow the ESD and safety
instructions for your site.
6. Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
126
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
7. Move the AC input switch on the chassis above the AC power supply or the DC circuit
breaker on each DC power-supply faceplate to the off (—) position.
8. Check that the AC or the DC power supply is correctly installed and functioning
normally. Verify that the AC OK and DC OK LEDs light steadily, and the PS FAIL LED is
not lit.
NOTE: After a power supply is powered on, it can take up to 60 seconds
for status indicators—such as the status LEDs on the power supply and
the show chassis command display—to indicate that the power supply is
functioning normally. Ignore error indicators that appear during the first
60 seconds.
If any of the status LEDs indicates that the power supply is not functioning normally,
repeat the installation and cabling procedures.
9. On the external management device connected to the Routing Engine, monitor the
startup process to verify that the system has booted properly.
NOTE: If the system is completely powered off when you power on the
power supply, the Routing Engine boots as the power supply completes
its startup sequence. Normally, the router boots from the Junos OS on the
CompactFlash card.
After turning on a power supply, wait at least 60 seconds before turning
it off.
Configuring Member IDs for the Virtual Chassis
To re-enable the Virtual Chassis, you must configure the member ID on both devices in
the Virtual Chassis configuration.
1.
Set the member ID on the router configured as member 0:
user@hostA> request virtual-chassis member-id set member 0
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
2. Repeat Step 1 to set the member ID on the router configured as member 1.
user@hostB> request virtual-chassis member-id set member 1
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] yes
The router reboots in preparation for forming the Virtual Chassis. After the reboot, all
MPCs remain powered off until the Virtual Chassis port connection is configured.
Copyright © 2017, Juniper Networks, Inc.
127
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
3. (Optional) Verify the member ID configuration for member 0.
For example:
{master:member0-re0}
user@hostA> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 4f2b.1aa0.de08
Mastership
List
Member ID
Interface
0 (FPC
Status
0- 11) Prsnt
Serial No
Model
JN10C7135AFC mx240
priority
129
Neighbor
Role
ID
Master*
4. (Optional) Verify the member ID configuration for member 1.
For example:
Amnesiac (ttyd0)
login: user
Password:
...
{master:member1-re0}
user> show virtual-chassis status
Virtual Chassis ID: ef98.2c6c.f7f7
Mastership
List
Member ID
Interface
1 (FPC
Status
12- 23) Prsnt
Serial No
Model
JN115D117AFB mx480
priority
128
Neighbor
Role
ID
Master*
NOTE: At this point in the configuration procedure, all line cards are offline,
and the routers are each designated with the Master role because they
are not yet interconnected as a fully formed Virtual Chassis. In addition,
member 1 remains in Amnesiac state (has no defined configuration) until
the Virtual Chassis forms and the configuration is committed.
128
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
Configuring Virtual Chassis Ports
Wait until the system is fully booted back up after setting the VC member IDs. VCP ports
need to be defined in order for line cards to function properly in the VC configuration.
1.
Log into the console port on member 0 and configure the first Virtual Chassis port
that connects to member 1.
{master:member0-re0}
user@host> request virtual-chassis vc-port set fpc-slot number pic-slot number port number
vc-port successfully set
After the Virtual Chassis port is created, it is renamed vcp-slot/pic/port (for example,
vcp-2/2/0), and the line card associated with that port comes online. The line cards
in the other member router remain offline until the Virtual Chassis forms. Each Virtual
Chassis port is dedicated to the task of interconnecting member routers in a Virtual
Chassis, and is no longer available for configuration as a standard network port.
2. Log into the console port on member 1 and configure the first Virtual Chassis port that
connects to member 0.
{master:member1-re0}
user@host> request virtual-chassis vc-port set fpc-slot number pic-slot number port number
vc-port successfully set
3. After establishing the VCP link, wait for all line cards and REs to come online. Confirm
the availability of ports that will be used as VCP links by issuing the show interface
command.
user@host> show interface xe-0/0/1
Physical interface: xe-0/0/1, Enabled, Physical link is Up
Interface index: 49195, SNMP ifIndex: 591
Link-level type: Ethernet, MTU: 1514, Speed: 10Gbps, Duplex: Full-Duplex,
BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering:
Disabled,
Flow control: Disabled
Device flags
: Present Running
Interface flags: SNMP-Traps Internal: 0x0
Link flags
: None
CoS queues
: 12 supported, 12 maximum usable queues
Current address: 00:1d:b5:f7:4e:e1, Hardware address: 00:1d:b5:f7:4e:e1
Last flapped
: 2011-06-01 00:42:03 PDT (00:02:42 ago)
Input rate
: 0 bps (0 pps)
Output rate
: 0 bps (0 pps)
Active alarms : None
Active defects : None
Logical interface xe-0/0/1.0 (Index 73) (SNMP ifIndex 523)
Flags: SNMP-Traps 0x0 Encapsulation: ENET2
Input packets : 0
Output packets: 0
Copyright © 2017, Juniper Networks, Inc.
129
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Protocol eth-switch, MTU: 0
Flags: Trunk-Mode
4. Configure the remaining VCP ports 1 at a time. Wait 30 seconds after setting each
VCP port.
user@host> request virtual-chassis vc-port set fpc-slot number pic-slot number port number
vc-port successfully set
Completing the SCBE2 Upgrade
To complete the SCBE2 upgrade procedure:
1.
Verify that the installation is successful and the SCBE2 is online by issuing the show
chassis environment cb command:
user@host> show chassis environment cb 0
CB 0 status
State Online
Temperature 30 degrees C / 86 degrees F
...
user@host> show chassis environment cb 1
CB 1 status
State Online
Temperature 30 degrees C / 86 degrees F
...
Other details, such as, temperature, power, etc are also displayed along with the state.
2. Verify that the fabric planes come online correctly by issuing the show chassis fabric
summary command:
user@host> show chassis fabric summary
Plane
State
Uptime
0
Online
2 days, 19 hours, 10 minutes, 9 seconds
1
Online
2 days, 19 hours, 10 minutes, 9 seconds
...
3. Verify that the backup Routing Engine is back online by issuing the show chassis
routing-engine 1 command:
user@host> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Current State Backup
...
4. Verify the SCBE2s before you finish by issuing the show chassis hardware command:
user@host> show chassis hardware
Hardware inventory:
Item
Version Part number
CB 0
REV 08
750-048307
CB 1
REV 08
750-048307
...
130
Serial number
CABC9829
CABC9828
Description
Enhanced MX SCB 2
Enhanced MX SCB 2
Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Configuring a Virtual Chassis
You see that the router now has SCBE2s.
Related
Documentation
•
Example: Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D
Universal Edge Routers by Rebooting the Routing Engines on page 165
•
Configuring Member IDs for a Virtual Chassis on page 72
•
Example: Replacing a Routing Engine in a Virtual Chassis Configuration for MX Series
3D Universal Edge Routers on page 99
Copyright © 2017, Juniper Networks, Inc.
131
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
132
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 4
Configuring Virtual Chassis Ports to
Interconnect Member Devices
•
Guidelines for Configuring Virtual Chassis Ports on page 134
•
Configuring Virtual Chassis Ports to Interconnect Member Routers or
Switches on page 136
•
Deleting Virtual Chassis Ports in a Virtual Chassis Configuration on page 138
Copyright © 2017, Juniper Networks, Inc.
133
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Guidelines for Configuring Virtual Chassis Ports
To interconnect the member routers in a Virtual Chassis for MX Series 3D Universal Edge
Routers, you must configure Virtual Chassis ports on Modular Port Concentrator/Modular
Interface Card (MPC/MIC) interfaces. After it is configured, a Virtual Chassis port is
dedicated to the task of interconnecting member routers, and is no longer available for
configuration as a standard network port.
NOTE: Starting with Junos OS Release 14.1, you can preconfigure ports that
are currently unavailable for use. Although a Virtual Chassis port is unavailable
for use as a standard network port, you can configure this port as a standard
network port even after you configure it as a Virtual Chassis port. However,
the router does not apply the configuration until you delete the Virtual Chassis
port from the Virtual Chassis configuration.
Consider the following guidelines when you configure Virtual Chassis ports in an MX
Series Virtual Chassis:
•
An MX Series Virtual Chassis supports up to 16 Virtual Chassis ports per trunk.
If two or more Virtual Chassis ports of the same type and speed (that is, either all
10-Gigabit Ethernet Virtual Chassis ports or all 1-Gigabit Ethernet Virtual Chassis ports)
are configured between the same two member routers in an MX Series Virtual Chassis,
the Virtual Chassis Control Protocol (VCCP) bundles these Virtual Chassis port
interfaces into a trunk, reduces the routing cost accordingly, and performs traffic load
balancing across all of the Virtual Chassis port interfaces in the trunk.
•
An MX Series Virtual Chassis does not support a combination of 1-Gigabit Ethernet (ge
media type) Virtual Chassis ports and 10-Gigabit Ethernet (xe media type) Virtual
Chassis ports within the same Virtual Chassis.
You must configure either all 10-Gigabit Virtual Chassis ports or all 1-Gigabit Virtual
Chassis ports in the same Virtual Chassis. We recommend that you configure Virtual
Chassis ports on 10-Gigabit Ethernet (xe) interfaces.
This restriction has no effect on access ports or uplink ports in an MX Series Virtual
Chassis configuration.
•
Configure redundant Virtual Chassis ports that reside on different line cards in each
member router.
NOTE: Virtual Chassis ports should be spread over all power zones in each
chassis to make the best use of physical redundancy in the router.
Distributing VCP interfaces minimizes the risk of split-mastership if power
zones are de-energized by PEM or power feed loss. With distributed VCP
interfaces, survival of a single power zone prevents split-master and other
undesirable protocol mastership conditions from occurring until all zones
are de-energized.
134
Copyright © 2017, Juniper Networks, Inc.
Chapter 4: Configuring Virtual Chassis Ports to Interconnect Member Devices
For a two-member MX Series Virtual Chassis, we recommend that you configure a
minimum of two 10-Gigabit Ethernet Virtual Chassis ports on different line cards in
each member router, for a total minimum of four 10-Gigabit Ethernet Virtual Chassis
ports in the Virtual Chassis. In addition, make sure the Virtual Chassis port bandwidth
is equivalent to no less than 50 percent of the aggregate bandwidth required for user
data traffic. The following examples illustrate these recommendations:
•
•
If the bandwidth in your network is equivalent to two 10-Gigabit Ethernet interfaces
(20 Gbps) on the access-facing side of the Virtual Chassis and two 10-Gigabit
Ethernet interfaces (20 Gbps) on the core-facing side of the Virtual Chassis, we
recommend that you configure two 10-Gigabit Ethernet Virtual Chassis ports, which
is the recommended minimum in a Virtual Chassis for redundancy purposes.
•
If the aggregate bandwidth in your network is equivalent to ten 10-Gigabit Ethernet
interfaces (100 Gbps), we recommend that you configure a minimum of five
10-Gigabit Ethernet Virtual Chassis ports, which is 50 percent of the aggregate
bandwidth.
A user data packet traversing the Virtual Chassis port interfaces between member
routers is discarded at the Virtual Chassis egress port if the MTU size of the packet
exceeds 9150 bytes.
The maximum MTU size of a Gigabit Ethernet interface or 10-Gigabit Ethernet interface
on a single MX Series router is 9192 bytes. In an MX Series Virtual Chassis configuration,
user data packets that traverse Gigabit Ethernet or 10-Gigabit Ethernet Virtual Chassis
port interfaces have 42 extra bytes of Virtual Chassis-specific header data, which
reduces their maximum MTU (payload) size to 9150 bytes. The user data packet is
transmitted in its entirety across the Virtual Chassis port interface. However, because
packet fragmentation and reassembly is not supported on Virtual Chassis port
interfaces, user data packets that exceed 9150 bytes are discarded at the Virtual
Chassis egress port.
Release History Table
Related
Documentation
Release
Description
14.1
Starting with Junos OS Release 14.1, you can preconfigure ports that are
currently unavailable for use.
•
Virtual Chassis Components Overview on page 24
•
Configuring Virtual Chassis Ports to Interconnect Member Routers or Switches on
page 136
•
Class of Service Overview for Virtual Chassis Ports on page 145
•
Guidelines for Configuring Class of Service for Virtual Chassis Ports on page 150
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
135
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Configuring Virtual Chassis Ports to Interconnect Member Routers or Switches
To interconnect the member routers in an MX Series Virtual Chassis, you must use the
request virtual-chassis vc-port set command to configure network ports into Virtual
Chassis ports on Modular Port Concentrator/Modular Interface Card (MPC/MIC)
interfaces. To interconnect the member switches into an EX9200 Virtual Chassis, you
must use the request virtual-chassis vc-port set command to configure network ports
into Virtual Chassis ports on line card interfaces. After the request virtual-chassis vc-port
set is configured on both ends of the link, a Virtual Chassis port that is dedicated to the
task of interconnecting member devices is created and the link can no longer be used as
a standard network port.
NOTE: If you issue the request virtual-chassis vc-port set command without
first installing an MX Virtual Chassis Redundancy Feature Pack license on
both member routers in an MX Series Virtual Chassis, the software displays
a warning message that you are operating without a valid Virtual Chassis
software license.
A software license is not needed to create an EX9200 Virtual Chassis.
To configure Virtual Chassis ports:
1.
Configure the Virtual Chassis ports on the router or switch configured as member 0.
a. Configure the first Virtual Chassis port that connects to member 1.
{local:member0-re0}
user@hostA> request virtual-chassis vc-port set fpc-slot fpc-slot-number pic-slot
pic-slot-number port port-number
After the Virtual Chassis port is created, it is renamed vcp-slot/pic/port, and the
line card associated with that port comes online. The line cards in the other member
devices remain offline until the Virtual Chassis forms.
For example, the following command configures Virtual Chassis port vcp-2/2/0
on member 0:
{local:member0-re0}
user@hostA> request virtual-chassis vc-port set fpc-slot 2 pic-slot 2 port 0
vc-port successfully set
b. When the first Virtual Chassis port is up on member 0, repeat Step 1a to configure
the second Virtual Chassis port that connects to member 1.
{local:member0-re0}
user@hostA> request virtual-chassis vc-port set fpc-slot fpc-slot-number pic-slot
pic-slot-number port port-number
2. Configure the Virtual Chassis ports on the device configured as member 1.
136
Copyright © 2017, Juniper Networks, Inc.
Chapter 4: Configuring Virtual Chassis Ports to Interconnect Member Devices
a. Configure the first Virtual Chassis port that connects to member 0.
{master:member1-re0}
user@hostB> request virtual-chassis vc-port set fpc-slot fpc-slot-number pic-slot
pic-slot-number port port-number
b. When the first Virtual Chassis port is up on member 1, repeat Step 2a to configure
the second Virtual Chassis port that connects to member 0.
{master:member1-re0}
user@hostB> request virtual-chassis vc-port set fpc-slot fpc-slot-number pic-slot
pic-slot-number port port-number
When all of the line cards in all of the member routers or switches are online, and the
Virtual Chassis has formed, you can issue Virtual Chassis commands from the terminal
window of the master router or switch.
NOTE: When the Virtual Chassis forms, the FPC slots are renumbered to
reflect the slot numbering and offsets used in the Virtual Chassis instead
of the physical slot numbers where the FPC is actually installed. Member
0 in the Virtual Chassis uses FPC slot numbers 0 through 11 with no offset,
and member 1 uses FPC slot numbers 12 through 23, with an offset of 12.
For example, a 10-Gigabit Ethernet interface that appears as xe-14/2/2
(FPC slot 14, PIC slot 2, port 2) in the show interfaces command output is
actually interface xe-2/2/2 (FPC slot 2, PIC slot 2, port 2) on member 1
after deducting the FPC slot numbering offset of 12 for member 1.
3. (Optional) Verify the that the Virtual Chassis is properly configured and that the Virtual
Chassis ports are operational.
{master:member0-re0}
user@hostA> show virtual-chassis status
{master:member0-re0}
user@hostA> show virtual-chassis vc-port all-members
4. Commit the configuration on the master router or switch.
The commit step is required to ensure that the configuration groups and Virtual Chassis
configuration are propagated to both members of the Virtual Chassis.
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis.
For an MX Series or Virtual Chassis, the force option is the default and only
behavior when you issue the commit synchronize command. Issuing the
commit synchronize command for an MX Series Virtual Chassis
Copyright © 2017, Juniper Networks, Inc.
137
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
configuration has the same effect as issuing the commit synchronize force
command.
Related
Documentation
•
Guidelines for Configuring Virtual Chassis Ports on page 134
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Deleting Virtual Chassis Ports in a Virtual Chassis Configuration
You can delete a Virtual Chassis port (vcp-slot/pic/port) as part of the procedure for
deleting a Virtual Chassis configuration. You can also delete a Virtual Chassis port when
you want to replace it with a Virtual Chassis port configured on a different FPC slot, PIC
slot, or port number in the router or switch. After you delete a Virtual Chassis port by
using the request virtual-chassis vc-port delete command, the port becomes available
to the global configuration and can again function as a standard network port.
NOTE: If you issue the request virtual-chassis vc-port delete command without
first installing an MX Virtual Chassis Redundancy Feature Pack license on
both member routers, the software displays a warning message that you are
operating without a valid Virtual Chassis software license.
A software license is not needed to create an EX9200 Virtual Chassis.
To remove the Virtual Chassis ports from both member devices in a Virtual Chassis:
1.
In the console window on the router or switch configured as member 0, remove one
or more Virtual Chassis ports.
{master:member0-re0}
user@host1> request virtual-chassis vc-port delete fpc-slot fpc-slot-number pic-slot
pic-slot-number port port-number
For example, the following command deletes vcp-2/2/0 (the Virtual Chassis port on
FPC slot 2, PIC slot 2, and port 0) from member 0 in the Virtual Chassis.
{master:member0-re0}
user@host1> request virtual-chassis vc-port delete fpc-slot 2 pic-slot 2 port 0
vc-port successfully deleted
2. In the console window on the router or switch configured as member 1, remove one or
more Virtual Chassis ports.
138
Copyright © 2017, Juniper Networks, Inc.
Chapter 4: Configuring Virtual Chassis Ports to Interconnect Member Devices
{master:member1-re0}
user@host2> request virtual-chassis vc-port delete fpc-slot fpc-slot-number pic-slot
pic-slot-number port port-number
3. (Optional) Confirm that the Virtual Chassis ports have been deleted from each of the
two member routers or switches.
When you delete a Virtual Chassis port, its name (vcp-slot/pic/port) no longer appears
in the output of the show virtual-chassis vc-port command. For example, the following
output for the show virtual-chassis vc-port command on each member router or switch
confirms that all Virtual Chassis ports have been deleted from both member devices.
For member 0 (host1):
{master:member0-re0}
user@host1> show virtual-chassis vc-port all-members
member0:
--------------------------------------------------------------------------
For member 1 (host2):
{backup:member1-re0}
user@host2> show virtual-chassis vc-port all-members
member1:
--------------------------------------------------------------------------
TIP: Deleting and then re-creating a Virtual Chassis port configuration may
cause the Virtual Chassis port to appear as Absent in the Status column of
the show virtual-chassis vc-port command display. To resolve this issue, reboot
the FPC that hosts the re-created Virtual Chassis port.
Related
Documentation
•
Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge Routers on
page 110
•
Configuring an EX9200 Virtual Chassis
•
Example: Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers on page 111
•
Guidelines for Configuring Virtual Chassis Ports on page 134
Copyright © 2017, Juniper Networks, Inc.
139
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
140
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 5
Configuring Locality Bias to Conserve
Bandwidth on Virtual Chassis Ports
•
Locality Bias in a Virtual Chassis on page 141
•
Guidelines for Configuring Locality Bias in a Virtual Chassis on page 143
•
Configuring Locality Bias for a Virtual Chassis on page 144
Locality Bias in a Virtual Chassis
By default, member routers in an MX Series Virtual Chassis distribute egress traffic equally
across all egress port links. Starting with Junos OS Release 14.1, if you want to conserve
bandwidth across the internal Virtual Chassis ports, you can use locality bias to direct
unicast transit traffic to egress links on the same (local) member router.
•
How Locality Bias Works on page 141
•
Locality Bias Percentages on page 142
How Locality Bias Works
Locality bias conserves Virtual Chassis port bandwidth in a two-member MX Series Virtual
Chassis by directing unicast transit traffic for equal-cost multipath (ECMP) groups and
aggregated Ethernet bundles to egress links in the same (local) member router, provided
that the local member router has an equal or larger number of available egress links than
the remote member router. Because locality bias directs all of the traffic towards the
local member router, Virtual Chassis ports do not use bandwidth.
However, if the number of available remote member router egress links exceeds the
number of available local member router egress links, the system reduces the amount
of traffic in the local member router by using a ratio that is based on the number of remote
versus local links. The amount of traffic that the system does not direct toward egress
links on the local member router is then split evenly across the egress links in the remote
member router.
If either the local member router or remote member router do not have available egress
links, then the traffic forwarding state across the Virtual Chassis ports does not change.
Copyright © 2017, Juniper Networks, Inc.
141
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Locality Bias Percentages
The router uses the following algorithms to determine the percentage of traffic that is
directed toward the local member router egress links, where L is the number of egress
links on the local member router and R is the number of egress links on the remote
member router.
BEST PRACTICE: To avoid possible traffic loss and oversubscription on egress
interfaces, make sure you understand the utilization requirements, such as
total and available bandwidth, for the local links in your network before
changing the locality bias configuration.
•
If L >= R, then Locality Bias Percentage = 100 percent and the local member router
receives all egress traffic.
For example, if the local member router and remote member router each contain one
egress link, then the locality bias is 100 percent. The router directs all unicast transit
traffic that is destined for an ECMP group or aggregated Ethernet bundle to the local
member router.
•
If L < R, then Locality Bias Percentage = 200 * (L / ( R + L ))
For example, if the local member router (L) contains one link and the remote member
router (R) contains two links, the locality bias percentage calculation is
200 * ( 1 / ( 2 + 1)) = 66
This means that the system directs 66 percent of the unicast transit traffic destined
for an ECMP group or aggregated Ethernet bundle toward the local member router.
The system splits the remaining 34 percent of the unicast transit traffic equally between
the remote member router egress links. Each of the two remote egress links in the
example receives 17 percent of the traffic.
NOTE: The actual amount of traffic that the local member router receives
can vary slightly from the percentages in the algorithm calculations.
•
If L = 0 or R = 0, then locality bias does not change the forwarding state.
For both the L < R and L >= R algorithms, locality bias percentages are recalculated on
each line card whenever one of the aggregated Ethernet child links goes up or down, or
whenever a link is added to or removed from an ECMP bundle.
NOTE: If an ECMP bundle has one or more child links that are aggregated
Ethernet links, then those aggregated Ethernet child links are always
considered remote unless all of the aggregated Ethernet child links are local.
142
Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Configuring Locality Bias to Conserve Bandwidth on Virtual Chassis Ports
Release History Table
Related
Documentation
Release
Description
14.1
Starting with Junos OS Release 14.1, if you want to conserve bandwidth across
the internal Virtual Chassis ports, you can use locality bias to direct unicast
transit traffic to egress links on the same (local) member router.
•
Guidelines for Configuring Locality Bias in a Virtual Chassis on page 143
•
Configuring Locality Bias for a Virtual Chassis on page 144
Guidelines for Configuring Locality Bias in a Virtual Chassis
Starting in Junos OS 14.1, you can configure locality bias in an MX Series Virtual Chassis.
Consider the following guidelines when doing so:
•
Make sure you know the total and available amounts of bandwidth in your network.
Enabling locality bias when local egress links do not have enough bandwidth to support
additional traffic can result in immediate traffic loss. The system does not prevent
configurations that result in oversubscription.
•
Locality bias directs only user traffic toward the local member router. Locality bias
does not affect load balancing of control traffic within the Virtual Chassis.
•
You cannot configure adaptive aggregated Ethernet load balancing and locality bias
together.
•
You cannot configure weighted load balancing and locality bias together.
Release History Table
Related
Documentation
Release
Description
14.1
Starting in Junos OS 14.1, you can configure locality bias in an MX Series
Virtual Chassis.
•
Locality Bias in a Virtual Chassis on page 141
•
Understanding Aggregated Ethernet Load Balancing
•
Configuring Locality Bias for a Virtual Chassis on page 144
Copyright © 2017, Juniper Networks, Inc.
143
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Configuring Locality Bias for a Virtual Chassis
Starting in Junos OS Release 14.1, configuring locality bias enables you to conserve Virtual
Chassis port bandwidth, reduce infrastructure costs, and reduce network latency in a
two-member MX Series Virtual Chassis. Locality bias works by directing unicast traffic
for equal-cost multipath (ECMP) groups and aggregated Ethernet bundles to egress
links in the same (local) member router in the Virtual Chassis rather than to egress links
in the remote member router.
You can enable locality bias by including the locality-bias statement at the [edit
virtual-chassis] hierarchy level.
BEST PRACTICE: To avoid possible traffic loss and oversubscription on egress
interfaces, make sure you understand the utilization requirements for the
local links in your network before changing the locality bias configuration.
To configure locality bias for an MX Series Virtual Chassis:
1.
Specify that you want to enable locality bias in the Virtual Chassis.
[edit virtual-chassis]
user@host# set locality-bias
2. Commit the configuration.
Release History Table
Related
Documentation
144
Release
Description
14.1
Starting in Junos OS Release 14.1, configuring locality bias enables you to
conserve Virtual Chassis port bandwidth, reduce infrastructure costs, and reduce
network latency in a two-member MX Series Virtual Chassis.
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Locality Bias in a Virtual Chassis on page 141
•
Guidelines for Configuring Locality Bias in a Virtual Chassis on page 143
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 6
Configuring Class of Service for Virtual
Chassis Ports
•
Class of Service Overview for Virtual Chassis Ports on page 145
•
Guidelines for Configuring Class of Service for Virtual Chassis Ports on page 150
•
Example: Configuring Class of Service for Virtual Chassis Ports on MX Series 3D
Universal Edge Routers on page 150
Class of Service Overview for Virtual Chassis Ports
By default, all Virtual Chassis port interfaces in a Virtual Chassis for MX Series 3D Universal
Edge Routers use a default class of service (CoS) configuration specifically tailored for
Virtual Chassis ports. The default configuration, which applies to all Virtual Chassis ports
in the Virtual Chassis, includes classifiers, forwarding classes, rewrite rules, and schedulers.
In most cases, the default CoS configuration is adequate for your needs without requiring
any additional CoS configuration.
In some cases, however, you might want to customize the traffic-control profile
configuration on Virtual Chassis ports. To do so, you can configure an output traffic-control
profile and apply it to all Virtual Chassis ports interfaces in the Virtual Chassis.
This topic provides an overview of the default CoS configuration for Virtual Chassis ports
and helps you understand the components of the CoS configuration that you can
customize.
•
Default CoS Configuration for Virtual Chassis Ports on page 145
•
Supported Platforms and Maximums for CoS Configuration of Virtual Chassis
Ports on page 146
•
Default Classifiers for Virtual Chassis Ports on page 147
•
Default Rewrite Rules for Virtual Chassis Ports on page 147
•
Default Scheduler Map for Virtual Chassis Ports on page 148
•
Customized CoS Configuration for Virtual Chassis Ports on page 149
Default CoS Configuration for Virtual Chassis Ports
In an MX Series Virtual Chassis configuration, the Virtual Chassis ports behave like switch
fabric ports to transport packets between the member routers in a Virtual Chassis. More
Copyright © 2017, Juniper Networks, Inc.
145
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
specifically, the Virtual Chassis ports carry internal control traffic within the Virtual Chassis
and forward user traffic between line cards in the router.
Like traffic on standard network port interfaces, traffic on Virtual Chassis port interfaces
is mapped to one of four forwarding classes, as follows:
•
Internal Virtual Chassis Control Protocol (VCCP) traffic is mapped to the network
control forwarding class with the code point (IEEE 802.1p bit) value set to ’111’b. You
cannot change this configuration.
•
Control traffic is mapped to the network control forwarding class with the code point
(IEEE 802.1p bit) value set to ’110’b. You cannot change this configuration.
•
User traffic is mapped to the best effort, expedited forwarding, and assured forwarding
traffic classes.
The CoS configuration applies globally to all Virtual Chassis ports in the Virtual Chassis.
You cannot configure CoS for an individual Virtual Chassis port (such as vcp-2/2/0). If
you create a new Virtual Chassis port, the global CoS configuration is propagated to the
newly created Virtual Chassis port when the member router on which the new Virtual
Chassis port resides joins the Virtual Chassis. Alternatively, you can configure CoS for the
Virtual Chassis ports by configuring CoS for a standard network port, and then converting
the network port to a Virtual Chassis port by issuing the request virtual-chassis vc-port
set command.
You can convert a standard network port (for example, xe-2/2/1) to a Virtual Chassis
port by issuing the request virtual-chassis vc-port set command. If the standard network
port was configured with different CoS settings than the CoS configuration in effect for
all Virtual Chassis ports in the Virtual Chassis, the newly converted Virtual Chassis port
(vcp-2/2/1) uses the CoS configuration defined for all Virtual Chassis port interfaces
instead of the original CoS configuration associated with the network port.
The default CoS configuration for Virtual Chassis ports provides the following benefits
to keep the Virtual Chassis operating properly:
•
Gives preference to internal VCCP traffic that traverses the Virtual Chassis port
interfaces
•
Prioritizes control traffic over user traffic on the Virtual Chassis port interfaces
•
Preserves the CoS properties of each packet as it travels between member routers in
the Virtual Chassis
Supported Platforms and Maximums for CoS Configuration of Virtual Chassis Ports
You can configure Virtual Chassis ports only on Modular Port Concentrator/Modular
Interface Card (MPC/MIC) interfaces in the following MX Series 3D Universal Edge Routers
with dual Routing Engines:
146
•
MX240 3D Universal Edge Router
•
MX480 3D Universal Edge Router
•
MX960 3D Universal Edge Router
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Configuring Class of Service for Virtual Chassis Ports
MPC/MIC interfaces support the following maximums for forwarding classes and priority
scheduling levels:
•
Up to eight forwarding classes
•
Up to five priority scheduling levels
Default Classifiers for Virtual Chassis Ports
Classification takes place when a packet enters a Virtual Chassis member router from a
network port. For Virtual Chassis configurations that support more than two member
routers, the packet is reclassified for CoS treatment according to the default IEEE 802.1p
classifier rules that apply to the Virtual Chassis port as the packet travels through the
intermediate member routers in the Virtual Chassis. When the packet enters the last
member router in the Virtual Chassis, it is reclassified according to the original classifier
rules that applied when the packet entered the Virtual Chassis from a network port.
NOTE: This reclassification behavior does not apply to an MX Series Virtual
Chassis, which supports only two member routers in the current release.
Because there are no intermediate member routers between the two member routers in
an MX Series Virtual Chassis, the packet is not reclassified according to the default
classifier rules for the Virtual Chassis port. Instead, the original classifier rules that applied
when the packet entered the Virtual Chassis on a network port are retained.
The default IEEE 802.1p classifier rules map the code point (or .1p bit) value to the
forwarding class and loss priority. You can display the default IEEE 802.1p classifier rules
by issuing the show class-of-service classifier command:
{master:member0-re0}
user@host> show class-of-service classifier type ieee-802.1
Classifier: ieee8021p-default, Code point type: ieee-802.1, Index: 11
Code point
Forwarding class
Loss priority
000
best-effort
low
001
best-effort
high
010
expedited-forwarding
low
011
expedited-forwarding
high
100
assured-forwarding
low
101
assured-forwarding
high
110
network-control
low
111
network-control
high
Default Rewrite Rules for Virtual Chassis Ports
When a packet enters the Virtual Chassis from a network port, normal CoS classification
takes place. If the packet exits a member router through the Virtual Chassis port to the
other member router, the CoS software encapsulates the packet with a virtual LAN
(VLAN) tag that contains the code point information used for CoS treatment. The code
point value is assigned according to the default IEEE 802.1p rewrite rules, which map the
forwarding class and loss priority value to a code point value.
Copyright © 2017, Juniper Networks, Inc.
147
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
You can display the default IEEE 802.1p rewrite rules by issuing the show class-of-service
rewrite-rule command:
{master:member0-re0}
user@host> show class-of-service rewrite-rule type ieee-802.1
Rewrite rule: ieee8021p-default, Code point type: ieee-802.1, Index: 34
Forwarding class
Loss priority
Code point
best-effort
low
000
best-effort
high
001
expedited-forwarding
low
010
expedited-forwarding
high
011
assured-forwarding
low
100
assured-forwarding
high
101
network-control
low
110
network-control
high
111
Default Scheduler Map for Virtual Chassis Ports
When you create a Virtual Chassis port, it automatically functions as a hierarchical
scheduler. However, you cannot explicitly configure hierarchical scheduling on Virtual
Chassis ports.
Virtual Chassis ports use the same default scheduler used by standard network ports.
The network control and best effort forwarding classes are both assigned low priority,
and only 5 percent of the bandwidth is allocated to control traffic.
You can display the scheduler parameters and the mapping of schedulers to forwarding
classes by issuing the show class-of-service scheduler-map command. For brevity, the
following example shows only the portions of the output relevant to the default best
effort (default-be) and default network control (default-nc) schedulers.
{master:member0-re0}
user@host> show class-of-service scheduler-map
Scheduler map: <default>, Index: 2
Scheduler: <default-be>, Forwarding class: best-effort, Index: 21
Transmit rate: 95 percent, Rate Limit: none, Buffer size: 95 percent, Buffer
Limit: none, Priority: low
Excess Priority: low
Drop profiles:
Loss priority
Protocol
Index
Name
Low
any
1
<default-drop-profile>
Medium low
any
1
<default-drop-profile>
Medium high
any
1
<default-drop-profile>
High
any
1
<default-drop-profile>
Scheduler: <default-nc>, Forwarding class: network-control, Index: 23
Transmit rate: 5 percent, Rate Limit: none, Buffer size: 5 percent, Buffer
Limit: none, Priority: low
Excess Priority: low
Drop profiles:
Loss priority
Protocol
Index
Name
Low
any
1
<default-drop-profile>
Medium low
any
1
<default-drop-profile>
Medium high
any
1
<default-drop-profile>
148
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Configuring Class of Service for Virtual Chassis Ports
High
any
1
<default-drop-profile>
...
Customized CoS Configuration for Virtual Chassis Ports
Depending on your network topology, you might want to customize the CoS configuration
for Virtual Chassis ports. For example, you might want to allocate more than the default
5 percent of the Virtual Chassis port bandwidth to control traffic. Or, you might want to
assign different priorities and excess rates to different forwarding classes.
Output Traffic-Control Profiles
To create a customized (nondefault) CoS configuration and apply it to all Virtual Chassis
ports, you can configure an output traffic-control profile, which defines a set of traffic
scheduling resources and references a scheduler map. You then apply the profile to all
Virtual Chassis port interfaces. To apply the output traffic-control profile globally to all
Virtual Chassis port interfaces, you must use vcp-* as the interface name representing
all Virtual Chassis port interfaces. You cannot configure CoS for an individual Virtual
Chassis port (such as vcp-1/1/0).
For an example that shows how to configure an output traffic-control profile customized
for Virtual Chassis ports, see “Example: Configuring Class of Service for Virtual Chassis
Ports on MX Series 3D Universal Edge Routers” on page 150.
Classifiers and Rewrite Rules
Configuring nondefault IEEE 802.1p ingress classifiers and IEEE 802.1p egress rewrite
rules has no effect in a two-member MX Series Virtual Chassis.
Because there are no intermediate routers between the two member routers in an MX
Series Virtual Chassis, packets are not reclassified according to the default classifier rules
for Virtual Chassis ports. Instead, the original classifier rules that applied when the packet
entered the Virtual Chassis on a network port are retained, making configuration of
nondefault ingress classifiers and nondefault egress rewrite rules unnecessary in the
current release.
Per-Priority Shaping
MPC/MIC interfaces support per-priority shaping, which enables you to configure a
separate traffic shaping rate for each of the five priority scheduling levels. However,
configuring per-priority shaping for Virtual Chassis ports on MPC/MIC interfaces is
unnecessary for the following reasons:
Related
Documentation
•
The neighboring member router has exactly the same bandwidth.
•
The same type of Virtual Chassis port is present at both ends of the connection.
•
Guidelines for Configuring Class of Service for Virtual Chassis Ports on page 150
•
Example: Configuring Class of Service for Virtual Chassis Ports on MX Series 3D
Universal Edge Routers on page 150
•
Junos OS Class of Service Library for Routing Devices
Copyright © 2017, Juniper Networks, Inc.
149
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Guidelines for Configuring Class of Service for Virtual Chassis Ports
Consider the following guidelines when you configure class of service (CoS) for Virtual
Chassis ports in an MX Series Virtual Chassis:
Related
Documentation
•
Virtual Chassis ports on MPC/MIC interfaces support a maximum of eight forwarding
classes and five priority scheduling levels.
•
The same CoS configuration applies globally to all Virtual Chassis ports in the Virtual
Chassis. You cannot configure CoS for an individual Virtual Chassis port (such as
vcp-3/1/0).
•
The CoS configuration is propagated to a newly created Virtual Chassis port as soon
as the member router on which the new Virtual Chassis port resides joins the Virtual
Chassis.
•
Although Virtual Chassis ports function as hierarchical schedulers, you cannot explicitly
configure hierarchical scheduling on Virtual Chassis ports.
•
If you configure a nondefault output traffic-control profile to customize the CoS
configuration, you must apply the profile to all Virtual Chassis port interfaces at once
by using vcp-* as the interface name.
•
Configuring nondefault IEEE 802.1p ingress classifiers and IEEE 802.1p egress rewrite
rules has no effect in a two-member MX Series Virtual Chassis because the forwarding
class assigned to a packet is maintained across the Virtual Chassis until the packet
reaches the egress network port.
•
Configuring per-priority shaping for Virtual Chassis ports is unnecessary because the
neighboring member router has exactly the same bandwidth, and the same type of
Virtual Chassis port is present at both ends of the connection.
•
Class of Service Overview for Virtual Chassis Ports on page 145
•
Example: Configuring Class of Service for Virtual Chassis Ports on MX Series 3D
Universal Edge Routers on page 150
•
Junos OS Class of Service Library for Routing Devices
Example: Configuring Class of Service for Virtual Chassis Ports on MX Series 3D
Universal Edge Routers
This example illustrates a typical class of service (CoS) configuration that you might
want to use for the Virtual Chassis ports in an MX Series Virtual Chassis.
150
•
Requirements on page 151
•
Overview on page 151
•
Configuration on page 152
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Configuring Class of Service for Virtual Chassis Ports
Requirements
Before you begin:
•
Configure a Virtual Chassis consisting of two MX Series routers.
See “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75
Overview
By default, all Virtual Chassis ports in an MX Series Virtual Chassis use a default CoS
configuration specifically tailored for Virtual Chassis ports. The default configuration,
which applies to all Virtual Chassis ports in the Virtual Chassis, includes classifiers,
forwarding classes, rewrite rules, and schedulers. This default CoS configuration prioritizes
internal Virtual Chassis Control Protocol (VCCP) traffic that traverses the Virtual Chassis
port interfaces, and prioritizes control traffic over user traffic on the Virtual Chassis ports.
In most cases, the default CoS configuration is adequate for your needs without requiring
any additional CoS configuration.
In some cases, however, you might want to customize the traffic-control profile
configuration on Virtual Chassis ports. For example, you might want to assign different
priorities and excess rates to different forwarding classes. To create a nondefault CoS
configuration, you can create an output traffic-control profile that defines a set of traffic
scheduling resources and references a scheduler map. You then apply the output
traffic-control profile to all Virtual Chassis port interfaces at once by using vcp-* as the
interface name representing all Virtual Chassis ports. You cannot configure CoS for Virtual
Chassis ports on an individual basis.
Table 19 on page 151 shows the nondefault CoS scheduler hierarchy configured in this
example for the Virtual Chassis ports.
Table 19: Sample CoS Scheduler Hierarchy for Virtual Chassis Ports
Queue
Number
Priority
Transmit Rate/
Excess Rate
Network control (VCCP
traffic)
3
Medium
90%
Expedited forwarding (voice
traffic)
2
High
10%
Assured forwarding (video
traffic)
1
Excess Low
99%
Best effort (data traffic)
0
Excess Low
1%
Traffic Type
Copyright © 2017, Juniper Networks, Inc.
151
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
In this example, you create a nondefault CoS configuration for Virtual Chassis ports by
completing the following tasks on the Virtual Chassis master router:
•
Associate forwarding classes with queue 0 through queue 3, and configure a fabric
priority value for each queue.
•
Configure an output traffic control profile named tcp-vcp-ifd to define traffic scheduling
parameters, and associate a scheduler map named sm-vcp-ifd with the traffic control
profile.
•
Apply the output traffic-control profile to the vcp-* interface, which represents all
Virtual Chassis port interfaces in the Virtual Chassis.
•
Associate the sm-vcp-ifd scheduler map with the forwarding classes and scheduler
configuration.
•
Configure the parameters for schedulers s-medium-priority, s-high-priority, s-low-priority,
s-high-weight, and s-low-weight.
Configuration
CLI Quick
Configuration
To quickly create a nondefault CoS configuration for Virtual Chassis ports, copy the
following commands and paste them into the router terminal window:
[edit]
set class-of-service forwarding-classes queue 0 best-effort
set class-of-service forwarding-classes queue 0 priority low
set class-of-service forwarding-classes queue 1 assured-forwarding
set class-of-service forwarding-classes queue 1 priority low
set class-of-service forwarding-classes queue 2 expedited-forwarding
set class-of-service forwarding-classes queue 2 priority high
set class-of-service forwarding-classes queue 3 network-control
set class-of-service forwarding-classes queue 3 priority high
set class-of-service traffic-control-profiles tcp-vcp-ifd scheduler-map sm-vcp-ifd
set class-of-service interfaces vcp-* output-traffic-control-profile tcp-vcp-ifd
set class-of-service scheduler-maps sm-vcp-ifd forwarding-class network-control
scheduler s-medium-priority
set class-of-service scheduler-maps sm-vcp-ifd forwarding-class expedited-forwarding
scheduler s-high-priority
set class-of-service scheduler-maps sm-vcp-ifd forwarding-class assured-forwarding
scheduler s-high-weight
set class-of-service scheduler-maps sm-vcp-ifd forwarding-class best-effort scheduler
s-low-weight
set class-of-service schedulers s-medium-priority transmit-rate percent 90
set class-of-service schedulers s-medium-priority priority medium-high
set class-of-service schedulers s-medium-priority excess-priority high
set class-of-service schedulers s-high-priority transmit-rate percent 10
set class-of-service schedulers s-high-priority priority high
set class-of-service schedulers s-high-priority excess-priority high
set class-of-service schedulers s-low-priority priority low
set class-of-service schedulers s-high-weight excess-rate percent 99
set class-of-service schedulers s-low-weight excess-rate percent 1
152
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Configuring Class of Service for Virtual Chassis Ports
Step-by-Step
Procedure
To create a nondefault CoS configuration for Virtual Chassis ports in an MX Series Virtual
Chassis:
1.
Log in to the console on the master router of the Virtual Chassis.
2.
Specify that you want to configure CoS forwarding classes.
{master:member0-re0} [edit]
user@host# edit class-of-service forwarding-classes
3.
Associate a forwarding class with each queue name and number, and configure a
fabric priority value for each queue.
{master:member0-re0} [edit class-of-service forwarding-classes]
user@host# set queue 0 best-effort priority low
user@host# set queue 1 assured-forwarding priority low
user@host# set queue 2 expedited-forwarding priority high
user@host# set queue 3 network-control priority high
4.
Return to the [edit class-of-service] hierarchy level to configure an output
traffic-control profile.
{master:member0-re0} [edit class-of-service forwarding-classes]
user@host# up
5.
Configure an output traffic-control profile and associate it with a scheduler map.
{master:member0-re0} [edit class-of-service]
user@host# set traffic-control-profiles tcp-vcp-ifd scheduler-map sm-vcp-ifd
6.
Apply the output traffic-control profile to all Virtual Chassis port interfaces in the
Virtual Chassis.
{master:member0-re0} [edit class-of-service]
user@host# set interfaces vcp-* output-traffic-control-profile tcp-vcp-ifd
7.
Specify that you want to configure the scheduler map.
{master:member0-re0} [edit class-of-service]
user@host# edit scheduler-maps sm-vcp-ifd
8.
Associate the scheduler map with the scheduler configuration and forwarding
classes.
{master:member0-re0} [edit class-of-service scheduler-maps sm-vcp-ifd]
user@host# set forwarding-class network-control scheduler s-medium-priority
user@host# set forwarding-class expedited-forwarding scheduler s-high-priority
user@host# set forwarding-class assured-forwarding scheduler s-high-weight
user@host# set forwarding-class best-effort scheduler s-low-weight
9.
Return to the [edit class-of-service] hierarchy level to configure the schedulers.
{master:member0-re0} [edit class-of-service scheduler-maps sm-vcp-ifd]
Copyright © 2017, Juniper Networks, Inc.
153
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
user@host# up 2
10.
Configure parameters for the schedulers.
{master:member0-re0} [edit class-of-service]
user@host# set schedulers s-medium-priority priority medium-high excess-priority
high transmit-rate percent 90
user@host# set schedulers s-high-priority priority high excess-priority high
transmit-rate percent 10
user@host# set schedulers s-low-priority priority low
user@host# set schedulers s-high-weight excess-rate percent 99
user@host# set schedulers s-low-weight excess-rate percent 1
Results
From the [edit class-of-service] hierarchy level in configuration mode, confirm the results
of your configuration by issuing the show statement. If the output does not display the
intended configuration, repeat the configuration instructions in this example to correct
it.
{master:member0-re0} [edit class-of-service]
user@host# show
forwarding-classes {
queue 0 best-effort priority low;
queue 1 assured-forwarding priority low;
queue 2 expedited-forwarding priority high;
queue 3 network-control priority high;
}
traffic-control-profiles {
tcp-vcp-ifd {
scheduler-map sm-vcp-ifd;
}
}
interfaces {
vcp-* {
output-traffic-control-profile tcp-vcp-ifd;
}
}
scheduler-maps {
sm-vcp-ifd {
forwarding-class network-control scheduler s-medium-priority;
forwarding-class expedited-forwarding scheduler s-high-priority;
forwarding-class assured-forwarding scheduler s-high-weight;
forwarding-class best-effort scheduler s-low-weight;
}
}
schedulers {
s-medium-priority {
transmit-rate percent 90;
priority medium-high;
excess-priority high;
}
s-high-priority {
transmit-rate percent 10;
priority high;
154
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Configuring Class of Service for Virtual Chassis Ports
excess-priority high;
}
s-low-priority {
priority low;
}
s-high-weight {
excess-rate percent 99;
}
s-low-weight {
excess-rate percent 1;
}
}
If you are done configuring CoS on the master router, enter commit from configuration
mode.
Related
Documentation
•
Class of Service Overview for Virtual Chassis Ports on page 145
•
Guidelines for Configuring Class of Service for Virtual Chassis Ports on page 150
•
Junos OS Class of Service Library for Routing Devices
Copyright © 2017, Juniper Networks, Inc.
155
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
156
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 7
Configuring Redundancy Mechanisms on
Aggregated Ethernet Interfaces in a Virtual
Chassis
•
Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual
Chassis on page 157
•
Configuring Module Redundancy for a Virtual Chassis on page 159
•
Configuring Chassis Redundancy for a Virtual Chassis on page 161
•
Multichassis Link Aggregation in a Virtual Chassis on page 162
•
Targeted Traffic Distribution on Aggregated Ethernet Interfaces in a Virtual
Chassis on page 163
Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual Chassis
Starting in Junos OS Release 13.2, an MX Series Virtual Chassis configured with targeted
traffic distribution for IP demux or VLAN demux subscribers on aggregated Ethernet
interfaces supports three types of redundancy mechanisms: link redundancy, module
redundancy, and chassis redundancy.
•
Link Redundancy in a Virtual Chassis on page 157
•
Module Redundancy in a Virtual Chassis on page 158
•
Chassis Redundancy in a Virtual Chassis on page 158
Link Redundancy in a Virtual Chassis
By default, the router uses link redundancy, also known as port redundancy, as the default
redundancy mechanism for targeted distribution on aggregated Ethernet interfaces. With
link redundancy, the router assigns backup links for a subscriber based on the link with
the fewest number of subscribers.
In an MX Series Virtual Chassis configured with link redundancy, the primary link and
backup link can be assigned on the same Modular Port Concentrator/Modular Interface
Card (MPC/MIC) module, on different MPC/MIC modules in the same member router,
or on different MPC/MIC modules in different member routers. This feature provides
redundancy if a link in the MX Series Virtual Chassis configuration fails.
Copyright © 2017, Juniper Networks, Inc.
157
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Because link redundancy is the default redundancy mechanism, no special configuration
is required on the Virtual Chassis master router to enable it.
Module Redundancy in a Virtual Chassis
You can configure module redundancy, also known as Flexible PIC Concentrator (FPC)
redundancy, to provide redundancy if a module or a link fails. The router assigns backup
links for the subscriber interface on a different MPC/MIC module from the primary link,
based on the link with the fewest number of subscribers among the links on different
modules.
In an MX Series Virtual Chassis configured with link redundancy, the router assigns the
primary link and backup link to different MPC/MIC modules. For purposes of link selection,
the router gives all MPC/MIC modules in the Virtual Chassis equal weight, and disregards
the role (master or backup) of the member router in which the MPC/MIC module is
installed. The router uses an algorithm to assign the primary and backup links, and is as
likely to assign a primary link to an MPC/MIC module in the Virtual Chassis master router
as it is to assign the primary link to an MPC/MIC module in the Virtual Chassis backup
router.
Chassis Redundancy in a Virtual Chassis
Unlike link redundancy and module redundancy, which are supported on both standalone
routers and Virtual Chassis member routers, chassis redundancy is available only for
member routers in an MX Series Virtual Chassis configuration.
Chassis redundancy and module redundancy use the same algorithm for link assignment,
with the exception that in a Virtual Chassis with chassis redundancy configured, the router
assigns the backup link to an MPC/MIC module in a member router other than the router
on which the primary link resides. For example, in a two-member MX Series Virtual Chassis,
if the primary link for the aggregated Ethernet bundle is assigned to an MPC/MIC module
in the Virtual Chassis master router, the router assigns the backup link to an MPC/MIC
module in the Virtual Chassis backup router.
Chassis redundancy provides protection if the MPC/MIC module containing the primary
link fails. In this event, the subscriber connections fail over to the backup link on the
MPC/MIC module in the other member router.
BEST PRACTICE: We recommend that you do not configure both module
(FPC) redundancy and chassis redundancy for the same aggregated Ethernet
interface in an MX Series Virtual Chassis. If you do, module redundancy takes
precedence over chassis redundancy.
158
Copyright © 2017, Juniper Networks, Inc.
Chapter 7: Configuring Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual Chassis
Release History Table
Related
Documentation
Release
Description
13.2
Starting in Junos OS Release 13.2, an MX Series Virtual Chassis configured with
targeted traffic distribution for IP demux or VLAN demux subscribers on
aggregated Ethernet interfaces supports three types of redundancy mechanisms:
link redundancy, module redundancy, and chassis redundancy.
•
Targeted Traffic Distribution on Aggregated Ethernet Interfaces in a Virtual Chassis on
page 163
•
Configuring Module Redundancy for a Virtual Chassis on page 159
•
Configuring Chassis Redundancy for a Virtual Chassis on page 161
Configuring Module Redundancy for a Virtual Chassis
By default, a router or switch uses link redundancy for aggregated Ethernet interfaces
(bundles) configured with targeted traffic distribution. Starting in Junos OS Release 13.2,
as an alternative to using link redundancy, you can configure module redundancy, also
known as FPC redundancy, for a Virtual Chassis configured with targeted traffic distribution
for IP demux or VLAN demux subscribers on aggregated Ethernet interfaces.
In a Virtual Chassis, module redundancy assigns the primary link and backup link to
different MPC/MIC modules or line cards, regardless of the Virtual Chassis role (master
or backup) of the member device in which the module is installed. Module redundancy
provides redundancy protection if a module or a link in the Virtual Chassis fails.
Before you begin:
•
Configure a Virtual Chassis consisting of two MX Series routers or two EX9200 switches.
See “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75
•
Ensure that the aggregated Ethernet bundle is configured without link protection.
See Configuring Aggregated Ethernet Link Protection
To configure module redundancy:
1.
Log in to the console on the master device of the Virtual Chassis.
2. Specify that you want to configure the demux logical interface.
{master:member0-re0} [edit]
user@host# edit interfaces demux0 unit logical-unit-number
3. Enable targeted distribution for the interface.
{master:member0-re0} [edit intefaces demux0 unit logical-unit-number]
user@host# set targeted-distribution
Copyright © 2017, Juniper Networks, Inc.
159
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
4. Specify the aggregated Ethernet bundle for which you want to configure module
redundancy.
{master:member0-re0} [edit]
user@host# edit interfaces aenumber aggregated-ether-options
5. Enable module (FPC) redundancy for the specified aggregated Ethernet bundle.
{master:member0-re0} [edit interfaces aenumber aggregated-ether-options]
user@host# set logical-interface-fpc-redundancy
BEST PRACTICE: We recommend that you do not configure both module
(FPC) redundancy and chassis redundancy for the same aggregated Ethernet
interface in the Virtual Chassis. If you do, module redundancy takes
precedence over chassis redundancy.
Release History Table
Related
Documentation
160
Release
Description
13.2
Starting in Junos OS Release 13.2, as an alternative to using link redundancy, you
can configure module redundancy, also known as FPC redundancy, for a Virtual
Chassis configured with targeted traffic distribution for IP demux or VLAN demux
subscribers on aggregated Ethernet interfaces.
•
Targeted Traffic Distribution on Aggregated Ethernet Interfaces in a Virtual Chassis on
page 163
•
Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual Chassis on
page 157
•
Configuring Chassis Redundancy for a Virtual Chassis on page 161
Copyright © 2017, Juniper Networks, Inc.
Chapter 7: Configuring Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual Chassis
Configuring Chassis Redundancy for a Virtual Chassis
By default, the router uses link redundancy for aggregated Ethernet interfaces (bundles)
configured with targeted traffic distribution. Starting in Junos OS Release 13.2, as an
alternative to using link redundancy, you can configure chassis redundancy for an
MX Series Virtual Chassis configured with targeted traffic distribution for IP demux or
VLAN demux subscribers on aggregated Ethernet interfaces.
In an MX Series Virtual Chassis, chassis redundancy assigns the backup link to an MPC/MIC
module in a member router other than the member router on which the primary link
resides. For example, in a two-member MX Series Virtual Chassis where the primary link
for the aggregated Ethernet bundle is on an MPC/MIC module in the master router, chassis
redundancy assigns the backup link for the bundle to an MPC/MIC module in the backup
router. Chassis redundancy provides protection if the MPC/MIC module containing the
primary link fails. In this event, the subscriber connections fail over to the backup link on
the MPC/MIC module in the other member router.
Unlike link redundancy and module redundancy, each of which are supported for both
standalone routers and Virtual Chassis member routers, chassis redundancy is available
only for member routers in an MX Series Virtual Chassis.
Before you begin:
•
Configure a Virtual Chassis consisting of two MX Series routers.
See “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75
•
Ensure that the aggregated Ethernet bundle is configured without link protection.
See Configuring Aggregated Ethernet Link Protection
To configure chassis redundancy for an MX Series Virtual Chassis:
1.
Log in to the console on the master router of the Virtual Chassis.
2. Specify that you want to configure the demux logical interface.
{master:member0-re0} [edit]
user@host# edit interfaces demux0 unit logical-unit-number
3. Enable targeted distribution for the interface.
{master:member0-re0} [edit intefaces demux0 unit logical-unit-number]
user@host# set targeted-distribution
4. Specify the aggregated Ethernet bundle for which you want to configure chassis
redundancy.
{master:member0-re0} [edit]
user@host# edit interfaces aenumber aggregated-ether-options
Copyright © 2017, Juniper Networks, Inc.
161
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
5. Enable module (FPC) redundancy for the specified aggregated Ethernet bundle.
{master:member0-re0} [edit interfaces aenumber aggregated-ether-options]
user@host# set logical-interface-chassis-redundancy
BEST PRACTICE: We recommend that you do not configure both module
(FPC) redundancy and chassis redundancy for the same aggregated Ethernet
interface in an MX Series Virtual Chassis. If you do, module redundancy takes
precedence over chassis redundancy.
Release History Table
Related
Documentation
Release
Description
13.2
Starting in Junos OS Release 13.2, as an alternative to using link redundancy, you
can configure chassis redundancy for an MX Series Virtual Chassis configured
with targeted traffic distribution for IP demux or VLAN demux subscribers on
aggregated Ethernet interfaces.
•
Targeted Traffic Distribution on Aggregated Ethernet Interfaces in a Virtual Chassis on
page 163
•
Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual Chassis on
page 157
•
Configuring Module Redundancy for a Virtual Chassis on page 159
Multichassis Link Aggregation in a Virtual Chassis
Starting in Junos OS Release 13.3, you can configure multichassis link aggregation
(MC-LAG) in an MX Series Virtual Chassis.
MC-LAG enables a device to form a logical link aggregation group interface with two or
more other devices. The MC-LAG devices use the Inter-Chassis Communication Protocol
(ICCP) to exchange control information between two MC-LAG network devices.
When you configure MC-LAG with an MX Series Virtual Chassis, the link aggregation
group spans links to two Virtual Chassis configurations. Each Virtual Chassis consists of
two MX Series member routers that form a logical system managed as a single network
element. ICCP exchanges control information between the global master router (VC-M)
of the first Virtual Chassis and the VC-M of the second Virtual Chassis.
To configure MC-LAG on member routers in a Virtual Chassis, use the same procedure
that you would use to configure MC-LAG on a standalone MX Series router.
NOTE: Internet Group Management Protocol (IGMP) snooping is not
supported on MC-LAG interfaces in an MX Series Virtual Chassis.
162
Copyright © 2017, Juniper Networks, Inc.
Chapter 7: Configuring Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual Chassis
Release History Table
Related
Documentation
Release
Description
13.3
Starting in Junos OS Release 13.3, you can configure multichassis link
aggregation (MC-LAG) in an MX Series Virtual Chassis.
•
Configuring Multichassis Link Aggregation on MX Series Routers
•
Global Roles and Local Roles in a Virtual Chassis on page 30
Targeted Traffic Distribution on Aggregated Ethernet Interfaces in a Virtual Chassis
By default, member routers or switches in an EX9200 or MX Series Virtual Chassis use
hash-based traffic distribution for subscriber interfaces in aggregated Ethernet bundles
configured without link protection. The hash-based model distributes subscriber interface
traffic over multiple links in the bundle, enabling you to load balance multiple traffic
flows through the logical subscriber interface.
Starting in Junos OS Release 13.2, as an alternative to using hash-based distribution in
an EX9200 or MX Series Virtual Chassis, you can configure targeted traffic distribution
for IP demultiplexing (demux) or VLAN demux subscriber interfaces in an aggregated
Ethernet bundle that is configured without link protection.
•
Targeted Distribution in a Virtual Chassis on page 163
•
Benefits of Targeted Distribution on page 163
Targeted Distribution in a Virtual Chassis
Targeted distribution enables you to configure the Virtual Chassis to send (target) all
egress data traffic for a logical subscriber interface across a single member link in an
aggregated Ethernet bundle, also referred to as an IEEE 802.3ad link aggregation group
(LAG) bundle. You configure targeted distribution for a demux subscriber interface on
the Virtual Chassis master router or switch.
With targeted distribution, the router or switch in a Virtual Chassis assigns the primary
member link and backup member link for the aggregated Ethernet bundle across all
Virtual Chassis port links that belong to the aggregated Ethernet bundle. To accomplish
load balancing, the router or switch evenly distributes the demux subscriber interfaces
over these member links.
Benefits of Targeted Distribution
Targeted distribution is especially useful in a Virtual Chassis configuration in which
subscriber traffic enters through a Virtual Chassis port on one member router or switch
and exits through a Virtual Chassis port on a different member router or switch. By
combining Virtual Chassis ports from different member router or switches as member
links of the aggregated Ethernet bundle, targeted distribution provides increased
redundancy in the event of a chassis or link failure.
Copyright © 2017, Juniper Networks, Inc.
163
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Release History Table
Related
Documentation
164
Release
Description
13.2
Starting in Junos OS Release 13.2, as an alternative to using hash-based distribution
in an EX9200 or MX Series Virtual Chassis, you can configure targeted traffic
distribution for IP demultiplexing (demux) or VLAN demux subscriber interfaces
in an aggregated Ethernet bundle that is configured without link protection.
•
Redundancy Mechanisms on Aggregated Ethernet Interfaces in a Virtual Chassis on
page 157
•
Configuring Module Redundancy for a Virtual Chassis on page 159
•
Configuring Chassis Redundancy for a Virtual Chassis on page 161
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 8
Upgrading Junos OS in a Virtual Chassis
Configuration for MX Series 3D Universal
Edge Routers by Rebooting the Routing
Engines
•
Example: Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D
Universal Edge Routers by Rebooting the Routing Engines on page 165
Example: Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D
Universal Edge Routers by Rebooting the Routing Engines
You can upgrade an MX Series Virtual Chassis configuration from Junos OS Release 11.2
to a later release by rebooting each of the Routing Engines. Both member routers in the
Virtual Chassis must have dual Routing Engines installed.
NOTE: Make sure all four Routing Engines in the Virtual Chassis (both Routing
Engines in the master router and both Routing Engines in the backup router)
are running the same Junos OS release.
This example describes how to upgrade Junos OS in a two-member MX Series Virtual
Chassis by rebooting the Routing Engines. For information about upgrading Junos OS in
an MX Series Virtual Chassis by performing a unified ISSU, see “Upgrading Junos OS in
an MX Series Virtual Chassis by Performing a Unified ISSU” on page 177.
•
Requirements on page 165
•
Overview and Topology on page 166
•
Configuration on page 167
Requirements
This example uses the following software and hardware and components:
•
Junos OS Release 12.3 and later releases
•
One MX240 3D Universal Edge Router with dual Routing Engines
Copyright © 2017, Juniper Networks, Inc.
165
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
One MX480 3D Universal Edge Router with dual Routing Engines
NOTE: This configuration example has been tested using the software release
listed and is assumed to work on all later releases.
See Table 20 on page 167 for information about the hardware installed in each MX Series
router.
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis.
For an MX Series Virtual Chassis, the force option is the default and only
behavior when you issue the commit synchronize command. Issuing the commit
synchronize command for an MX Series Virtual Chassis configuration has the
same effect as issuing the commit synchronize force command.
Overview and Topology
To upgrade Junos OS in an MX Series Virtual Chassis configuration by rebooting the
Routing Engines, you must:
1.
Prepare for the upgrade.
2. Install the Junos OS software package on each of the four Routing Engines.
3. Re-enable graceful Routing Engine switchover and nonstop active routing.
4. Reboot the Routing Engines to run the new Junos OS release.
This example upgrades Junos OS in an MX Series Virtual Chassis configuration that uses
the basic topology shown in Figure 5 on page 166. For redundancy, each member router
is configured with two Virtual Chassis ports.
Figure 5: Sample Topology for a Virtual Chassis with Two MX Series
Routers
Virtual Chassis
Active
Standby
Access Node
Active
Standby
Access Node
Core
vcp-2/2/0
vcp-2/3/0
vcp-2/0/0
vcp-5/2/0
trefoil
MX480
member 1
Service
Provider
Network
Core
g017471
Subscribers
gladius
MX240
member 0
Table 20 on page 167 shows the hardware and software configuration settings for each
MX Series router in the Virtual Chassis.
166
Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D Universal Edge Routers by Rebooting the Routing Engines
Table 20: Components of the Sample MX Series Virtual Chassis
Router
Name
Hardware
Serial
Number
Member
ID
gladius
MX240 router with:
JN10C7135AFC
JN115D117AFB
trefoil
•
60-Gigabit Ethernet
Enhanced Queuing
MPC
•
20-port Gigabit
Ethernet MIC with SFP
•
4-port 10-Gigabit
Ethernet MIC with XFP
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member0-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member0-re1)
MX480 router with:
•
Two 30-Gigabit
Ethernet Queuing
MPCs
•
Two 20-port Gigabit
Ethernet MICs with
SFP
•
Two 2-port 10-Gigabit
Ethernet MICs with
XFP
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member1-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member1-re1)
Role
Virtual Chassis
Ports
Network Port
Slot Numbering
0
routing-engine
(master)
vcp-2/2/0
vcp-2/3/0
FPC 0 – 11
1
routing-engine
(backup)
vcp-2/0/0
vcp-5/2/0
FPC 12 – 23
(offset = 12)
Configuration
To upgrade Junos OS in a two-member MX Series Virtual Chassis by rebooting the Routing
Engines, perform these tasks:
•
Preparing for the Upgrade on page 168
•
Installing the Junos OS Software Package on Each Routing Engine on page 169
Copyright © 2017, Juniper Networks, Inc.
167
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
Re-enabling Graceful Routing Engine Switchover and Nonstop Active
Routing on page 170
•
Rebooting the Routing Engines to Run the New Junos OS Release on page 170
Preparing for the Upgrade
Step-by-Step
Procedure
To prepare for the upgrade process:
1.
Use FTP or a Web browser to download the Junos OS software package to the
master Routing Engine on the Virtual Chassis master router (VC-M).
See Downloading Software.
2.
Disable nonstop active routing on the master router.
{master:member0-re0}[edit routing-options]
user@gladius# deactivate nonstop-routing
3.
Disable graceful Routing Engine switchover on the master router.
{master:member0-re0}[edit chassis redundancy]
user@gladius# deactivate graceful-switchover
4.
Commit the configuration on the master router.
5.
Exit CLI configuration mode.
{master:member0-re0}[edit]
user@gladius# exit
168
Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D Universal Edge Routers by Rebooting the Routing Engines
Installing the Junos OS Software Package on Each Routing Engine
Step-by-Step
Procedure
Installing the Junos OS software package on each Routing Engine in an MX Series Virtual
Chassis prepares the Routing Engines to run the new software release after a reboot.
This action is also referred to as arming the Routing Engines.
To install the Junos OS software package on all four Routing Engines from the master
router (member0-re0) in the Virtual Chassis:
•
Install the software package on VC-Mm.
{master:member0-re0}
user@gladius> request system software add package-name
On a properly formed Virtual Chassis, this command propagates the image to all
four Routing Engines.
Results
Display the results of the installation. Verify that the correct software package has been
installed on the local master Routing Engine in member 0 (member0-re0) and on the
local master Routing Engine in member 1 (member1-re0).
user@gladius> show version invoke-on all-routing-engines
member0-re0:
-------------------------------------------------------------------------Hostname: gladius
Model: mx240
. . .
JUNOS Installation Software [14.1R1.10]
member0-re1:
-------------------------------------------------------------------------Hostname:gladius1
Model: mx240
. . .
JUNOS Installation Software [14.1R1.10]
member1-re0:
-------------------------------------------------------------------------Hostname: trefoil
Model: mx240
. . .
JUNOS Installation Software [14.1R1.10]
member1-re1:
-------------------------------------------------------------------------Hostname: trefoil1
Model: mx240
. . .
JUNOS Installation Software [14.1R1.10]
Copyright © 2017, Juniper Networks, Inc.
169
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Re-enabling Graceful Routing Engine Switchover and Nonstop Active Routing
Step-by-Step
Procedure
After upgrading the Junos OS release, you need to re-enable graceful Routing Engine
switchover and nonstop active routing for the Virtual Chassis.
To re-enable graceful Routing Engine switchover and nonstop active routing from the
Virtual Chassis master router (member0-re0):
1.
In the console window on member 0 (gladius), enable graceful Routing Engine
switchover on the master router.
{master:member0-re0}[edit chassis redundancy]
user@gladius# activate graceful-switchover
2.
Re-enable nonstop active routing on the master router.
{master:member0-re0}[edit routing-options]
user@gladius# activate nonstop-routing
3.
Commit the configuration on the master router.
Rebooting the Routing Engines to Run the New Junos OS Release
Step-by-Step
Procedure
NOTE: Rebooting both Routing Engines in the VC-M chassis may not result
in a graceful switchover to the VC-B chassis, and is not recommended.
To reboot each of the four Routing Engines in an MX Series Virtual Chassis from the
Virtual Chassis master router (member0-re0):
•
Use the request system reboot command with no options.
{master:member0-re0}
user@gladius> request system reboot
This command reboots all line cards in member 0 (gladius) and member 1 (trefoil)
to use the new Junos OS release. A traffic disruption occurs until all line cards are
back online and the Virtual Chassis re-forms.
Related
Documentation
170
•
Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified ISSU on
page 177
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Virtual Chassis Components Overview on page 24
•
Switchover Behavior in an MX Series Virtual Chassis on page 34
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 9
Upgrading Junos OS in an MX Series
Virtual Chassis by Performing a Unified
In-Service Software Upgrade (ISSU)
•
Unified ISSU in a Virtual Chassis on page 171
•
Preparing for a Unified ISSU in an MX Series Virtual Chassis on page 175
•
Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified
ISSU on page 177
Unified ISSU in a Virtual Chassis
Starting in Junos OS Release 14.1, you can perform a unified in-service software upgrade
(unified ISSU) for an MX Series Virtual Chassis configuration. Unified ISSU enables you
to upgrade the Junos OS system software on the Virtual Chassis member routers with
minimal traffic disruption and no disruption on the control plane.
This topic assumes that you are familiar with the global roles and local roles in an MX
Series Virtual Chassis. For information, see “Global Roles and Local Roles in a Virtual
Chassis” on page 30.
•
Benefits of Performing a Unified ISSU in an Virtual Chassis on page 171
•
Prerequisites for Performing a Unified ISSU in a Virtual Chassis on page 172
•
How Unified ISSU Works in a Virtual Chassis on page 172
•
Virtual Chassis Role Transitions After a Unified ISSU on page 173
Benefits of Performing a Unified ISSU in an Virtual Chassis
Performing a unified ISSU in an MX Series Virtual Chassis provides the following benefits:
•
Upgrades the Junos OS software package while maintaining subscriber sessions.
•
Reduces risk associated with a software upgrade. After performing a unified ISSU, the
resulting system is exactly the same as if you had upgraded it with a system reboot.
•
Prevents software upgrades from negatively affecting the service provider’s ability to
fulfill strict service-level agreements (SLAs).
•
Eliminates network downtime during software image upgrades.
Copyright © 2017, Juniper Networks, Inc.
171
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
Enables faster implementation of new Junos OS features.
•
Provides feature parity with unified ISSU support on standalone MX Series routers.
Prerequisites for Performing a Unified ISSU in a Virtual Chassis
Before you start a unified ISSU in a two-member MX Series Virtual Chassis, make sure
you do all of the following:
•
Ensure that all four Routing Engines in the Virtual Chassis (both Routing Engines in the
master router and both Routing Engines in the backup router) are running the same
Junos OS software release.
•
Back up the existing router configuration so you can revert (roll back) to it if necessary.
•
Verify that both graceful Routing Engine switchover (GRES) and nonstop active routing
(NSR) are enabled.
How Unified ISSU Works in a Virtual Chassis
To perform a unified ISSU in an MX Series Virtual Chassis, you issue the request system
software in-service-upgrade package-name command from the console window for the
master Routing Engine in the Virtual Chassis master router (VC-Mm). Issuing this
command from the VC-Mm copies the software package to all other Routing Engines in
the Virtual Chassis.
The request system software in-service-upgrade package-name command functions the
same for upgrading member routers in a Virtual Chassis configuration as it does for
upgrading a standalone MX Series router with dual Routing Engines, with the following
exceptions:
•
The no-copy, no-old-master-upgrade, and unlink options for the request system software
in-service-upgrade command are not available for an MX Series Virtual Chassis.
•
The reboot option for the request system software in-service-upgrade command is
accepted but ignored for an MX Series Virtual Chassis. A unified ISSU always reboots
all Routing Engines in the Virtual Chassis member routers.
At a high level, the software performs the following actions after you issue the request
system software in-service-upgrade package-name command to upgrade to a new
Junos OS software release in a two-member Virtual Chassis configuration:
1.
Arms the new Junos OS software release on all Routing Engines in the Virtual Chassis.
The Routing Engines are still running the old Junos OS software release.
2. Upgrades both standby (backup) Routing Engines (VC-Ms and VC-Bs) in the Virtual
Chassis.
The Virtual Chassis is still actively forwarding traffic.
3. Performs a local switchover of the Routing Engines in the Virtual Chassis backup router
(VC-B).
172
Copyright © 2017, Juniper Networks, Inc.
Chapter 9: Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified In-Service Software Upgrade (ISSU)
The local switchover causes the VC-Bs upgraded in Step 2 to become the VC-Bm,
and the VC-Bm that was still running the old Junos OS software to become the VC-Bs.
The VC-Bm is now running the new Junos OS software release, and the VC-Bs is still
running the old Junos OS software release. The Virtual Chassis is still actively
forwarding traffic.
4. Upgrades the Packet Forwarding Engines to the new Junos OS software release.
The Packet Forwarding Engines are now using the upgraded VC-Bm as the Virtual
Chassis protocol master.
5. Performs a local switchover of the Routing Engines in the Virtual Chassis master router
(VC-M).
The local switchover of the VC-M also causes a global switchover in the Virtual Chassis,
which causes the VC-M to become the VC-B. As a result, the VC-Mm becomes the
VC-Bs, and the VC-Ms becomes the VC-Bm. The global switchover on the VC-B causes
the VC-Bm to become the VC-Mm, and the VC-Bs to become the VC-Ms.
The VC-Mm and VC-Bm are now running the new Junos OS software release. The
VC-Ms (originally the VC-Bm) and VC-Bs (originally the VC-Mm) are still running the
old Junos OS software release.
6. Upgrades the standby Routing Engines in the Virtual Chassis (VC-Ms and VC-Bs).
The Virtual Chassis is now fully upgraded to the new Junos OS software release.
Virtual Chassis Role Transitions After a Unified ISSU
A unified ISSU in an MX Series Virtual Chassis upgrades all Routing Engines in the Virtual
Chassis to the new Junos OS software release. In a two-member Virtual Chassis, this
includes four Routing Engines: the master and standby (backup) Routing Engines in the
Virtual Chassis master router, and the master and standby Routing Engines in the Virtual
Chassis backup router. As a result, the member routers and their associated Routing
Engines undergo both global and local role transitions after the unified ISSU completes.
A global role transition changes the mastership in the Virtual Chassis by switching the
global roles of the Virtual Chassis master router (VC-M) and Virtual Chassis backup
router (VC-B), and applies globally across the entire Virtual Chassis. A local role transition
toggles the local mastership roles (master and standby, or m and s) of each of the two
Routing Engines in a member router, and applies locally only to that member router.
A unified ISSU in an MX Series Virtual Chassis causes the global and local role transitions
listed in Table 21 on page 173.
Table 21: Virtual Chassis Role Transitions After Unified ISSU
Virtual Chassis Role Before Unified
ISSU
Virtual Chassis Role After Unified
ISSU
Type of Role
Change
Virtual Chassis master router (VC-M)
Virtual Chassis backup router (VC-B)
Global
Copyright © 2017, Juniper Networks, Inc.
173
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 21: Virtual Chassis Role Transitions After Unified ISSU (continued)
Release History Table
Related
Documentation
174
Virtual Chassis Role Before Unified
ISSU
Virtual Chassis Role After Unified
ISSU
Type of Role
Change
Virtual Chassis backup router (VC-B)
Virtual Chassis master router (VC-M)
Global
Master Routing Engine in the Virtual
Chassis master router (VC-Mm)
Standby Routing Engine in the Virtual
Chassis backup router (VC-Bs)
Local
Standby Routing Engine in the Virtual
Chassis master router (VC-Ms)
Master Routing Engine in the Virtual
Chassis backup router (VC-Bm)
Local
Master Routing Engine in the Virtual
Chassis backup router (VC-Bm)
Standby Routing Engine in the Virtual
Chassis master router (VC-Ms)
Local
Standby Routing Engine in the Virtual
Chassis backup router (VC-Bs)
Master Routing Engine in the Virtual
Chassis master router(VC-Mm)
Local
Release
Description
14.1
Starting in Junos OS Release 14.1, you can perform a unified in-service
software upgrade (unified ISSU) for an MX Series Virtual Chassis
configuration.
•
Preparing for a Unified ISSU in an MX Series Virtual Chassis on page 175
•
Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified ISSU on
page 177
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Unified ISSU System Requirements
Copyright © 2017, Juniper Networks, Inc.
Chapter 9: Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified In-Service Software Upgrade (ISSU)
Preparing for a Unified ISSU in an MX Series Virtual Chassis
Starting in Junos OS Release 14.1, you can perform a unified in-service software upgrade
(unified ISSU) in an MX Series Virtual Chassis. Before you begin such an upgrade, perform
the following tasks to help ensure its success.
NOTE: For recommended settings on MX Virtual Chassis devices, please
consult Maximizing Scaling and Performance for MX Series Virtual Chassis on
the Juniper Networks Knowledge Base.
To prepare for a unified ISSU in a two-member MX Series Virtual Chassis:
1.
Back up the existing system software to each member router’s hard disk so you can
roll back to it if necessary.
Isssue the request system snapshot all-members command to archive data and
executable areas for all members of the Virtual Chassis configuration.
2. Make sure enhanced IP network services is configured.
See “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75.
3. Verify that both graceful Routing Engine switchover (GRES) and nonstop active routing
(NSR) are enabled.
See “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75.
4. Make sure the router is configured to delay for 180 seconds (3 minutes) before
removing access routes and access-internal routes for DHCP and PPP subscriber
management after a graceful Routing Engine switchover takes place.
See Delaying Removal of Access Routes and Access-Internal Routes After Graceful
Routing Engine Switchover.
5. Ensure that the router is configured to use a hold-time value of 300 seconds when
negotiating a BGP connection with the peer.
See BGP Messages Overview.
6. Stop all CPU-intensive periodic operations running on the Virtual Chassis in order to
conserve system resources.
Examples of such CPU-intensive operations include, but are not limited to, periodic
SNMP Get and SNMP Walk requests, isssuing Junos OS operational mode commands
with detailed or extensive output, and runnning Stylesheet Language Alternative
Syntax (SLAX) operational scripts that monitor device status or network events.
Copyright © 2017, Juniper Networks, Inc.
175
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
7. (Aggregated Ethernet interfaces only) If you are using aggregated Ethernet interfaces,
make sure each interface is configured to use a slow interval (every 30 seconds) for
periodic transmission of Link Aggregation Control Protocol (LACP) packets.
See Configuring LACP for Aggregated Ethernet Interfaces.
8. (IS-IS interfaces only) If you are using IS-IS interfaces configured with the iso protocol
family, make sure the link-state PDU lifetime value (lsp-lifetime) is set to
65317 seconds.
See Example: Configuring the Transmission Frequency for Link-State PDUs on IS-IS
Interfaces.
BEST PRACTICE: For additional information about unified ISSU, consult our
Knowledge Base.
Release History Table
Related
Documentation
176
Release
Description
14.1
Starting in Junos OS Release 14.1, you can perform a unified in-service
software upgrade (unified ISSU) in an MX Series Virtual Chassis.
•
Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified ISSU on
page 177
•
Unified ISSU in a Virtual Chassis on page 171
Copyright © 2017, Juniper Networks, Inc.
Chapter 9: Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified In-Service Software Upgrade (ISSU)
Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified ISSU
Starting in Junos OS Release 14.1, you can upgrade the member routers in a two-member
MX Series Virtual Chassis to a later release by performing a unified in-service software
upgrade (unified ISSU). Unified ISSU enables you to upgrade to a new Junos OS software
release with minimal traffic disruption and no loss of subscriber sessions.
The unified ISSU procedure upgrades and changes the roles of all Routing Engines in the
Virtual Chassis to the new Junos OS software release. In a two-member Virtual Chassis,
this includes four Routing Engines: the master and standby Routing Engines in the Virtual
Chassis master router, and the master and standby Routing Engines in the Virtual Chassis
backup router.
This procedure describes how to upgrade Junos OS in an MX Series Virtual Chassis by
performing a unified ISSU. For information about upgrading Junos OS in an MX Series
Virtual Chassis by rebooting the Routing Engines, see “Example: Upgrading Junos OS in
a Virtual Chassis Configuration for MX Series 3D Universal Edge Routers by Rebooting
the Routing Engines” on page 165.
Before you begin a unified ISSU in a two-member MX Series Virtual Chassis, perform the
following tasks:
•
Prepare the member routers for the unified ISSU operation.
See “Preparing for a Unified ISSU in an MX Series Virtual Chassis” on page 175.
To perform a unified ISSU in a two-member MX Series Virtual Chassis:
1.
Use FTP or a Web browser to download the Junos OS software package from the
Juniper Networks Support Web site.
See Downloading Software.
2. Open four console windows to access the console ports on each of the four Routing
Engines in the Virtual Chassis:
•
Master Routing Engine in the Virtual Chassis master router (VC-Mm)
•
Standby Routing Engine in the Virtual Chassis master router (VC-Ms)
•
Master Routing Engine in the Virtual Chassis backup router (VC-Bm)
•
Standby Routing Engine in the Virtual Chassis backup router (VC-Bs)
Opening separate console windows enables you to monitor the progress of the unified
ISSU on each of the Routing Engines.
3. (Optional but recommended) Confirm that the member routers are ready for the
unified ISSU process.
Issue the following commands in each console window:
{master:member0-re0}
Copyright © 2017, Juniper Networks, Inc.
177
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
user@host> show virtual-chassis vc-port | match “Configured”
user@host> show system switchover local
user@host> show system uptime local
Issuing these commands provides the following information:
•
The show virtual-chassis vc-port | match “Configured” command output confirms
that all Virtual Chassis port interfaces are properly configured and operational.
•
The show system switchover local command output confirms that the configuration
database and kernel database are ready for a unified ISSU.
•
The show system uptime local command output displays the date and time when
this Routing Engine was last booted, and how long it has been running. It typically
takes from 5 minutes to 15 minutes since the last switchover or system reboot for
the Routing Engine to be ready for a unified ISSU.
4. Verify that all four Routing Engines in the Virtual Chassis are running the same Junos
OS software release.
Issue the show version invoke-on all-routing-engines command with the all-members
option to display the hostnames and version information about the software running
on all Routing Engines in the Virtual Chassis.
{master:member0-re0}
user@host> show version all-members invoke-on all-routing-engines
5. Initiate the unified ISSU process.
In the console window on the VC-Mm, issue the request system software
in-service-upgrade package-name command.
{master:member0-re0}
user@host> request system software in-service-upgrade package-name
NOTE: You do not need to specify the reboot option for the request system
software in-service-upgrade command because a unified ISSU in an MX
Series Virtual Chassis always reboots all Routing Engines in the member
routers.
For MX series routers with RE-S-X6-64G Routing Engine, upgrade the
guest Junos OS and the Linux VM host OS by issuing the request vmhost
software in-service-upgrade package-name command.
6. Check the console windows for each Routing Engine to monitor the unified ISSU
progress and determine when the upgrade is complete.
The unified ISSU can take between 30 minutes and 90 minutes to complete, depending
on the size of your configuration. When the unified ISSU completes, the login prompt
appears in the console windows.
178
Copyright © 2017, Juniper Networks, Inc.
Chapter 9: Upgrading Junos OS in an MX Series Virtual Chassis by Performing a Unified In-Service Software Upgrade (ISSU)
For an example of the output for a unified ISSU operation in an MX Series Virtual Chassis,
see request system software in-service-upgrade and request vmhost software
in-service-upgrade.
Release History Table
Related
Documentation
Release
Description
14.1
Starting in Junos OS Release 14.1, you can upgrade the member routers in a
two-member MX Series Virtual Chassis to a later release by performing a unified
in-service software upgrade (unified ISSU).
•
Preparing for a Unified ISSU in an MX Series Virtual Chassis on page 175
•
Unified ISSU in a Virtual Chassis on page 171
•
Example: Performing a Unified ISSU
•
Unified ISSU System Requirements
•
Example: Upgrading Junos OS in a Virtual Chassis Configuration for MX Series 3D
Universal Edge Routers by Rebooting the Routing Engines on page 165
Copyright © 2017, Juniper Networks, Inc.
179
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
180
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 10
Monitoring an MX Series Virtual Chassis
•
Accessing the Virtual Chassis Through the Management Interface on page 182
•
Verifying the Status of Virtual Chassis Member Routers or Switches on page 183
•
Verifying the Operation of Virtual Chassis Ports on page 183
•
Verifying Neighbor Reachability for Member Routers or Switches in a Virtual
Chassis on page 184
•
Verifying Neighbor Reachability for Hardware Devices in a Virtual Chassis on page 184
•
Determining GRES Readiness in a Virtual Chassis Configuration on page 185
•
Viewing Information in the Virtual Chassis Control Protocol Adjacency
Database on page 186
•
Viewing Information in the Virtual Chassis Control Protocol Link-State
Database on page 187
•
Viewing Information About Virtual Chassis Port Interfaces in the Virtual Chassis Control
Protocol Database on page 188
•
Viewing Virtual Chassis Control Protocol Routing Tables on page 188
•
Viewing Virtual Chassis Control Protocol Statistics for Member Devices and Virtual
Chassis Ports on page 189
•
Verifying and Managing the Virtual Chassis Heartbeat Connection on page 190
•
Inline Flow Monitoring for Virtual Chassis Overview on page 191
•
Managing Files on Virtual Chassis Member Routers or Switches on page 193
•
Virtual Chassis SNMP Traps on page 194
•
Virtual Chassis Slot Number Mapping for Use with SNMP on page 194
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
Copyright © 2017, Juniper Networks, Inc.
181
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Accessing the Virtual Chassis Through the Management Interface
The management Ethernet interface (fxp0) on an MX Series router or EX9200 switch is
an out-of-band management interface, also referred to as a management port, that
enables you to use Telnet or SSH to access and manage the device remotely. You typically
configure the management interface with an IP address and prefix length when you first
install Junos OS.
You can configure a management Ethernet interface in one of two ways to access a
Virtual Chassis:
•
To access the Virtual Chassis as a whole, configure a consistent IP address for the
management interface using the master-only option. You can use this management
IP address to consistently access the master (primary) Routing Engine in the master
router or switch (protocol master) for the Virtual Chassis.
•
To access a specific Routing Engine in an individual member router or switch of the
Virtual Chassis, configure an IP address for one of the following configuration groups:
•
member0-re0
•
member0-re1
•
member1-re0
•
member1-re1
BEST PRACTICE: For most management tasks, we recommend that you
access the Virtual Chassis as a whole through a consistent management IP
address. For troubleshooting purposes, however, accessing a specific Routing
Engine in an individual member router or switch may be useful.
To access a Virtual Chassis through the management Ethernet interface, do one of the
following:
•
Configure a consistent management IP address that accesses the entire Virtual Chassis
through the master Routing Engine in the Virtual Chassis master router or switch.
{master:member0-re0}[edit]
user@host# set interfaces fxp0 unit 0 family inet address ip-address/prefix-length
master-only
For example, to access the entire Virtual Chassis via management IP address
10.4.5.33/16:
{master:member0-re0}[edit]
user@host# set interfaces fxp0 unit 0 family inet address 10.4.5.33/16 master-only
•
Configure a management IP address that accesses a specified Routing Engine in an
individual member router or switch in the Virtual Chassis.
{master:member0-re0}[edit groups]
182
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
user@host# set membern-ren interfaces fxp0 unit 0 family inet address
ip-address/prefix-length
For example, to access the Routing Engine installed in slot 1 of member router 1
(member1-re1) in the Virtual Chassis:
{master:member0-re0}[edit groups]
user@host# set member1-re1 interfaces fxp0 unit 0 family inet address 10.4.3.145/32
Related
Documentation
•
Configuring a Consistent Management IP Address
Verifying the Status of Virtual Chassis Member Routers or Switches
Purpose
Action
Verify that the member routers or switches in an MX Series or EX9200 Virtual Chassis
are properly configured.
Display the status of the members of the Virtual Chassis configuration:
user@host> show virtual-chassis status
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Verifying the Operation of Virtual Chassis Ports
Purpose
Action
Verify that the Virtual Chassis ports in an MX Series or EX9200 Virtual Chassis are properly
configured and operational.
•
To display the status of the Virtual Chassis ports for both member routers or switches
in the Virtual Chassis:
user@host> show virtual-chassis vc-port all-members
•
To display the status of the Virtual Chassis ports for a specified member router or
switch in the Virtual Chassis:
user@host> show virtual-chassis vc-port member member-id
•
To display the status of the Virtual Chassis ports for the member router or switch on
which you are issuing the command:
user@host> show virtual-chassis vc-port local
Copyright © 2017, Juniper Networks, Inc.
183
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Verifying Neighbor Reachability for Member Routers or Switches in a Virtual Chassis
Purpose
Action
Verify that each member router or switch in an MX Series or EX9200 Virtual Chassis has
a path to reach the neighbor devices to which it is connected.
•
To display neighbor reachability information for both member devices in the Virtual
Chassis:
user@host> show virtual-chassis active-topology all-members
•
To display neighbor reachability information for a specified member device in the Virtual
Chassis:
user@host> show virtual-chassis active-topology member member-id
•
To display neighbor reachability information for the member device on which you are
issuing the command:
user@host> show virtual-chassis active-topology local
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Verifying Neighbor Reachability for Hardware Devices in a Virtual Chassis
Purpose
Action
Verify that each hardware device in an MX Series Virtual Chassis or an EX9200 Virtual
Chassis can reach the neighbor routers and devices to which it is connected. On the MX
Series routing platform, there is only one active device for each member router.
•
To display neighbor reachability information for the devices in both member routers
in the Virtual Chassis:
user@host> show virtual-chassis device-topology all-members
•
184
To display neighbor reachability information for the device in a specified member router
in the Virtual Chassis:
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
user@host> show virtual-chassis device-topology member member-id
•
To display neighbor reachability information for the device in the member router on
which you are issuing the command:
user@host> show virtual-chassis device-topology local
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Determining GRES Readiness in a Virtual Chassis Configuration
Depending on the configuration, a variable amount of time is required before a router or
switch is ready to perform a graceful Routing Engine switchover (GRES). Attempting a
GRES operation before the device is ready can cause system errors and unexpected
behavior.
To determine whether the member routers or switches in a Virtual Chassis configuration
are ready for a GRES operation from a database synchronization perspective, you can
issue the request virtual-chassis routing-engine master switch check command from the
Virtual Chassis master router or switch (VC-Mm) before you initiate the GRES operation.
Using the request virtual-chassis routing-engine master switch check command before
you initiate the GRES operation ensures that the subscriber management and kernel
databases on both member routers or switches are synchronized and ready for the GRES
operation.
To determine whether the member routers or switches are ready for GRES from a
database synchronization perspective:
1.
Issue the request virtual-chassis routing-engine master switch check command from
the Virtual Chassis master router or switch (VC-Mm).
{master:member0-re0}
user@host> request virtual-chassis routing-engine master switch check
The request virtual-chassis routing-engine master switch check command checks
various system and database components on the member routers or switches to
determine whether they are ready for GRES, but does not initiate the global GRES
operation itself. The readiness check includes ensuring that a system timer, which
expires after 300 seconds, completes before the global GRES operation begins.
Copyright © 2017, Juniper Networks, Inc.
185
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
2. Review the results of the request virtual-chassis routing-engine master switch check
command to determine whether the member routers or switches are ready for a GRES
operation from a database synchronization perspective.
•
If the member routers or switches are ready for GRES, the request virtual-chassis
routing-engine master switch check command displays a message confirming GRES
readiness. For example:
{master:member0-re0}
user@host> request virtual-chassis routing-engine master switch check
Switchover Ready
•
If the member routers or switches are not ready for GRES, the request virtual-chassis
routing-engine master switch check command displays information about the
readiness of the system. For example:
{master:member0-re0}
user@host> request virtual-chassis routing-engine master switch check
error: chassisd Not ready for mastership switch, try after 217 secs.
mastership switch request NOT honored, backup not ready
The specific command output differs depending on the GRES readiness state of
the member routers or switches.
Related
Documentation
•
Switchover Behavior in an MX Series Virtual Chassis on page 34
•
Virtual Chassis Components Overview on page 24
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Understanding Graceful Routing Engine Switchover
Viewing Information in the Virtual Chassis Control Protocol Adjacency Database
Purpose
Action
View information about neighbors in the Virtual Chassis Control Protocol (VCCP)
adjacency database for a Virtual Chassis configuration.
•
To display VCCP neighbor adjacency information for both member devices in the Virtual
Chassis:
user@host> show virtual-chassis protocol adjacency all-members
•
To display VCCP neighbor adjacency information for a specified member device in the
Virtual Chassis:
user@host> show virtual-chassis protocol adjacency member member-id
•
To display VCCP neighbor adjacency information for the device with a specified system
ID:
user@host> show virtual-chassis protocol adjacency system-id
186
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
•
To display VCCP neighbor adjacency information for the device with a specified system
ID on the specified member router or switch:
user@host> show virtual-chassis protocol adjacency member member-id system-id
•
To display VCCP neighbor adjacency information for the member device on which you
are issuing the command:
user@host> show virtual-chassis protocol adjacency local
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Viewing Information in the Virtual Chassis Control Protocol Link-State Database
Purpose
Action
View information about protocol data unit (PDU) packets in the Virtual Chassis Control
Protocol (VCCP) link-state database for a Virtual Chassis configuration.
•
To display VCCP PDU information for both member routers or switches in the Virtual
Chassis:
user@host> show virtual-chassis protocol database all-members
•
To display VCCP PDU information for a specified member router or switch in the Virtual
Chassis:
user@host> show virtual-chassis protocol database member member-id
•
To display VCCP PDU information for the device with a specified system ID:
user@host> show virtual-chassis protocol database system-id
•
To display VCCP PDU information for the device with a specified system ID on the
specified member router or switch:
user@host> show virtual-chassis protocol database member member-id system-id
•
To display VCCP PDU information for the member router or switch on which you are
issuing the command:
user@host> show virtual-chassis protocol database local
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
Copyright © 2017, Juniper Networks, Inc.
187
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Viewing Information About Virtual Chassis Port Interfaces in the Virtual Chassis Control
Protocol Database
Purpose
Action
View information in the Virtual Chassis Control Protocol (VCCP) database about Virtual
Chassis port interfaces in the Virtual Chassis.
•
To display VCCP information about Virtual Chassis port interfaces for both member
routers or switches:
user@host> show virtual-chassis protocol interface all-members
•
To display VCCP information about Virtual Chassis port interfaces for a specified
member router or switch:
user@host> show virtual-chassis protocol interface member member-id
•
To display VCCP information about a specified Virtual Chassis port interface:
user@host> show virtual-chassis protocol interface vcp-slot/pic/port.logical-unit-number
•
To display VCCP information about Virtual Chassis port interfaces for the member
router or switch on which you are issuing the command:
user@host> show virtual-chassis protocol interface local
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Viewing Virtual Chassis Control Protocol Routing Tables
Purpose
Action
View Virtual Chassis Control Protocol (VCCP) unicast and multicast routing tables for
an MX Series Virtual Chassis configuration.
•
To display the VCCP unicast and multicast routing tables for both member routers in
the Virtual Chassis:
user@host> show virtual-chassis protocol route all-members
188
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
•
To display the VCCP unicast and multicast routing tables for a specified member router
in the Virtual Chassis:
user@host> show virtual-chassis protocol route member member-id
•
To display the VCCP unicast and multicast routing tables to the destination with the
specified system ID:
user@host> show virtual-chassis protocol route destination-id
•
To display the VCCP unicast and multicast routing tables to the destination with the
specified system ID on the specified member router:
user@host> show virtual-chassis protocol route member member-id destination-id
•
To display the VCCP unicast and multicast routing tables for the member router on
which you are issuing the command:
user@host> show virtual-chassis protocol route local
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Viewing Virtual Chassis Control Protocol Statistics for Member Devices and Virtual
Chassis Ports
Purpose
Action
View Virtual Chassis Control Protocol (VCCP) statistics for one or both member routers
or switches, or for a specified Virtual Chassis port interface, in a Virtual Chassis
configuration.
•
To display VCCP statistics for both member routers or switches in the Virtual Chassis:
user@host> show virtual-chassis protocol statistics all-members
•
To display VCCP statistics for a specified member router or switch in the Virtual Chassis:
user@host> show virtual-chassis protocol statistics member member-id
•
To display VCCP statistics for a specified Virtual Chassis port interface:
user@host> show virtual-chassis protocol statistics vcp-slot/pic/port.logical-unit-number
•
To display VCCP statistics for the member router or switch on which you are issuing
the command:
user@host> show virtual-chassis protocol statistics local
Copyright © 2017, Juniper Networks, Inc.
189
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Related
Documentation
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Verifying and Managing the Virtual Chassis Heartbeat Connection
Purpose
Verify the configuration and operation of a heartbeat connection for an MX Series Virtual
Chassis.
NOTE: Starting in Junos OS Release 14.1, you can configure a heartbeat
connection for an MX Series Virtual Chassis.
Action
•
To clear heartbeat connection statistics counters and timestamp fields for all (both)
member routers, the specified member router, or the member router on which you are
issuing the command:
user@host> clear virtual-chassis heartbeat <all-members>
user@host> clear virtual-chassis heartbeat member member-id
user@host> clear virtual-chassis heartbeat local
•
To view the heartbeat connection state for all (both) member routers, the specified
member router, or the member router on which you are issuing the command:
user@host> show virtual-chassis heartbeat <all-members>
user@host> show virtual-chassis heartbeat member member-id
user@host> show virtual-chassis heartbeat local
•
To display and review the statistics collected by the heartbeat connection for all (both)
member routers, the specified member router, or the member router on which you are
issuing the command:
user@host> show virtual-chassis heartbeat detail <all-members>
user@host> show virtual-chassis heartbeat detail member member-id
user@host> show virtual-chassis heartbeat detail local
•
To verify use (status) of the heartbeat connection when an adjacency disruption or
split is detected in the Virtual Chassis:
user@host> show virtual-chassis status
190
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
Release History Table
Related
Documentation
Release
Description
14.1
Starting in Junos OS Release 14.1, you can configure a heartbeat connection
for an MX Series Virtual Chassis.
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
•
Virtual Chassis Heartbeat Connection Overview on page 41
Inline Flow Monitoring for Virtual Chassis Overview
Inline flow monitoring enables you to monitor the flow of traffic by means of a router or
switch participating in a network.
Inline flow monitoring for an MX Series Virtual Chassis or an EX9200 Virtual Chassis
supports the following features:
•
Active sampling and exporting of both IPv4 and IPv6 traffic flows. Active (inline)
sampling occurs on an inline data path without the need for a services DPC.
•
Sampling traffic flows in both the ingress and egress directions.
•
Configuring flow collection on either IPv4 or IPv6 devices.
•
Using the IPFIX flow collection template for traffic sampling. The IPFIX template
supports both IPv4 and IPv6 export records.
•
Sampling and exporting of VPLS flows
•
Exporting of data in Version-IPFIX and Version 9 formats
Consider the following guidelines when you configure Virtual Chassis for inline flow
monitoring.
•
Split Detection on page 191
•
Syntax of the sampling-instance Statement on page 192
•
FPC Slot Numbers for the Virtual Chassis on page 192
Split Detection
In a two-member MX Series Virtual Chassis or an EX9200 Virtual Chassis , you must
disable split detection to configure and use inline flow monitoring. To do so, include the
no-split-detection statement at the [edit virtual-chassis] hierarchy level when you set
up the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
191
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Syntax of the sampling-instance Statement
To associate a sampling instance with an FPC in the Virtual Chassis master router
(member ID 0), use the sampling-instance instance-name statement at the [edit chassis
member member-number fpc slot slot-number] hierarchy level, where member-number is
0 (zero) and slot-number is a number in the range 0 through 11. For example, the following
statement associates a sampling instance named sample1 to the FPC in slot 1 of a Virtual
Chassis master router:
[edit chassis member 0 fpc slot 1]
user@host# set sampling-instance sample1
To associate a sampling instance with an FPC in the Virtual Chassis backup router
(member ID 1), use the sampling-instance instance-name statement at the [edit chassis
member member-number fpc slot slot-number] hierarchy level, where member-number is
1 and slot-number is a number in the range 0 through 11. For example, the following
statement associates a sampling instance named sample2 to the FPC in slot 2 of Virtual
Chassis backup router:
[edit chassis member 1 fpc slot 2]
user@host# set sampling-instance sample2
FPC Slot Numbers for the Virtual Chassis
After you configure the member ID and, optionally, slot count for each router that you
want to add to the Virtual Chassis, the Routing Engines in that chassis reboot and the
slots for line cards (FPCs) are renumbered. The FPC slot numbering used for each member
router is based on the slot count and offsets used in the Virtual Chassis instead of the
physical slot numbers where the line card is actually installed.
For example, assume that in your Virtual Chassis configuration, member 0 is an MX960
router and member 1 is an MX2010 router, with the default slot count (12) in effect on
both routers. In this topology, a 10-Gigabit Ethernet interface that appears as xe-14/2/2
(FPC slot 14, PIC slot 2, port 2) in the show services accounting status inline-jflow command
output or the show interfaces command output is actually physical interface xe-2/2/2
(FPC slot 2, PIC slot 2, port 2) on member 1 after deducting the offset of 12 for member 1.
NOTE: Platform support and associated slots depend on the Junos OS release
in your installation.
For more information about how slot count and slot numbering work in an MX Series
Virtual Chassis, see “Virtual Chassis Components Overview” on page 24.
Related
Documentation
192
•
Configuring Inline Active Flow Monitoring
•
Sampling Instance Configuration
•
no-split-detection on page 241
•
Disabling Split Detection in a Virtual Chassis Configuration on page 98
•
Split Detection Behavior in a Virtual Chassis on page 38
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
Managing Files on Virtual Chassis Member Routers or Switches
In a Virtual Chassis configuration for MX Series 3D Universal Edge Routers or EX9200
switches, you can manage files on local and remote member routers or switches by
including a member specification in the following file operational commands:
file archive
file copy
file checksum md5
file delete
file checksum sha1
file list
file checksum sha-256
file rename
file compare
file show
The member specification identifies the specific Virtual Chassis member router or switch
and Routing Engine on which you want to manage files, and includes both of the following
elements:
•
The Virtual Chassis member ID (0 or 1)
•
The Routing Engine slot number (re0 or re1)
To manage files on a specific member router or switch and a specific Routing Engine:
•
From operational mode, issue the file command and Virtual Chassis member
specification:
{master:member0-re0}
user@host> file option member(0 | 1)-re(0 | 1):command-option
For example, the following file list command uses the member1-re0 specification to
display a list of the files in the /config directory on the Routing Engine in slot 0 (re0) in
Virtual Chassis member 1. The router or switch forwards the command from member
0, where it is issued, to member 1, and displays the results as if the command were
processed on the local device.
{master:member0-re0}
user@host> file list member1-re0:/config
member1-re0:
-------------------------------------------------------------------------/config:
.snap/
juniper.conf.1.gz
juniper.conf.2.gz
juniper.conf.3.gz
juniper.conf.gz
juniper.conf.md5
license/
license.old/
Copyright © 2017, Juniper Networks, Inc.
193
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
usage.db
vchassis/
Related
Documentation
•
Interchassis Redundancy and Virtual Chassis Overview on page 19
•
Virtual Chassis Components Overview on page 24
•
Format for Specifying Filenames and URLs in Junos OS CLI Commands
Virtual Chassis SNMP Traps
Junos OS supports the use of SNMP traps to monitor the routers, switches, and other
devices in your network.
MX Virtual Chassis supports the following enterprise-specific traps:
•
jnxVccpPortUp
•
jnxVccpPortDown
An unexpected SNMP trap of jnxVccpPortDown with a jnxVirtualChassisPortOperStatus
value of 2 (down) should be treated as a critical notification, as it indicates one or more
of the VCP-interfaces has undergone a failure, and may result in degraded performance
or decreased resiliency to further errors until the status is cleared by a jnxVccpPortUp
with jnxVirtualChassisPortOperStatus value equal to 1 (up).
A detailed description may be found in the MIB, located
http://www.juniper.net/techpubs/en_US/junos15.1/topics/reference/mibs/mib-jnx-virtualchassis.txt.
Related
Documentation
•
Virtual Chassis Slot Number Mapping for Use with SNMP on page 194
•
Virtual Chassis Components Overview on page 24
•
SNMP MIB Explorer
Virtual Chassis Slot Number Mapping for Use with SNMP
Junos OS supports the use of SNMP to monitor the routers, switches, and other devices
in your network. For example, the Juniper Networks jnxBoxAnatomy enterprise-specific
Chassis MIB contains the jnxFruTable object, which shows the status of field-replaceable
units (FRUs) in the chassis. Within the jnxFruTable object, the jnxFruSlot object displays
the slot number where the FRU is installed.
If you are using the jnxFruSlot object in jnxFruTable to display the slot numbers of line
cards installed in a member router of an MX Series Virtual Chassis or a member switch
of an EX9200 Virtual Chassis, keep in mind that the offset used for slot numbering in the
Virtual Chassis affects the value that appears for the jnxFruSlot object.
Table 22 on page 195 lists the jnxFruSlot number that appears in the jnxFruTable of the
jnxBoxAnatomy MIB, and the corresponding line card physical slot number in each member
router of a two-member EX9200 or MX Series Virtual Chassis. For example, a jnxFruSlot
194
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
value of 15 corresponds to physical slot 3 in member 0 of the Virtual Chassis. A jnxFruSlot
value of 30 corresponds to physical slot 6 in member 1 of the Virtual Chassis.
Table 22: jnxFruSlot Numbers and Corresponding Slot Numbers in an MX
Series or EX9200 Virtual Chassis
jnxFruSlot Number
Line Card Slot Number
MX Series or EX9200 Virtual Chassis
Member ID
Line Cards in MX Series Virtual Chassis Member ID 0 (offset = 12):
12
0
0
13
1
0
14
2
0
15
3
0
16
4
0
17
5
0
18
6
0
19
7
0
20
8
0
21
9
0
22
10
0
23
11
0
Line Cards in MX Series Virtual Chassis Member ID 1 (offset = 24)
24
0
1
25
1
1
26
2
1
27
3
1
28
4
1
29
5
1
30
6
1
Copyright © 2017, Juniper Networks, Inc.
195
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 22: jnxFruSlot Numbers and Corresponding Slot Numbers in an MX
Series or EX9200 Virtual Chassis (continued)
Related
Documentation
jnxFruSlot Number
Line Card Slot Number
MX Series or EX9200 Virtual Chassis
Member ID
31
7
1
32
8
1
33
9
1
34
10
1
35
11
1
•
Virtual Chassis Components Overview on page 24
•
SNMP MIB Explorer
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet
A heartbeat connection is an IP-based, bidirectional packet connection in an MX Series
Virtual Chassis between the Virtual Chassis master and backup routers. The heartbeat
packets exchanged over this connection provide critical information about the availability
and health of each member router. Starting in Junos OS Release 14.1, you can configure
a heartbeat connection in an MX Series Virtual Chassis.
This example describes how to configure a heartbeat connection in an MX Series Virtual
Chassis when both member routers reside in the same subnet. For information about
configuring a heartbeat connection when the Virtual Chassis member routers reside in
different subnets, see “Example: Determining Member Health Using an MX Series Virtual
Chassis Heartbeat Connection with Member Routers in Different Subnets” on page 207.
•
Requirements on page 196
•
Overview on page 197
•
Configuration on page 199
•
Verification on page 204
Requirements
This example uses the following software and hardware components:
•
Junos OS Release 14.1 and later releases
•
Two MX240 3D Universal Edge Routers, each with dual Routing Engines
This configuration example has been tested using the software release listed and is
assumed to work on all later releases.
196
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis. For an
MX Series Virtual Chassis, the force option is the default and only behavior
when you issue the commit synchronize command. Issuing the commit
synchronize command for an MX Series Virtual Chassis configuration has the
same effect as issuing the commit synchronize force command.
Before you configure a heartbeat connection for a Virtual Chassis:
•
Configure a Virtual Chassis consisting of two MX Series routers.
See “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75
As part of the preprovisioned Virtual Chassis configuration shown in the configuration
example, you must create and apply the member0-re0, member0-re1, member1-re0,
and member1-re1 configuration groups for each member Routing Engine. Each
configuration group includes a unique IP address for the management Ethernet interface
(fxp0) on each Routing Engine.
NOTE: When you create the preprovisioned Virtual Chassis configuration
at the [edit virtual-chassis] hierarchy level, make sure you do not configure
the no-split-detection statement to disable detection of a split in the Virtual
Chassis. Using the no-split-detection statement is prohibited when you
configure a Virtual Chassis heartbeat connection, and doing so causes the
commit operation to fail.
•
Ensure TCP connectivity between the master Routing Engine in the Virtual Chassis
master router (VC-Mm) and the master Routing Engine in the Virtual Chassis backup
router (VC-Bm).
The Virtual Chassis heartbeat connection opens a proprietary TCP port numbered
33087 on the VC-Mm to listen for heartbeat messages. If your network design includes
firewalls or filters, make sure the network allows traffic between TCP port 33087 on
the VC-Mm and the dynamically allocated TCP port on the VC-Bm.
Overview
A heartbeat connection is an IP-based, bidirectional packet connection between the
master router and backup router in an MX Series Virtual Chassis. The member routers
forming the heartbeat connection exchange heartbeat packets that provide critical
information about the availability and health of each member router. During a disruption
or split in the Virtual Chassis configuration, the heartbeat connection prevents the member
routers from changing mastership roles unnecessarily, which can cause undesirable
results.
This example configures a heartbeat connection for an MX Series Virtual Chassis in which
both MX240 member routers reside in the 10.4.0.0 subnet. Member router caelum is the
Copyright © 2017, Juniper Networks, Inc.
197
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
global master router for the Virtual Chassis (VC-M), and member router elnath is the
global backup router (VC-B). Both member routers have dual Routing Engines installed,
and the heartbeat connection is configured between the master Routing Engine in caelum
(represented by VC-Mm or member0-re0) and the master Routing Engine in elnath
(represented by VC-Bm or member1-re0).
Configuring a heartbeat connection for an MX Series Virtual Chassis when both member
routers reside in the same subnet consists of the following tasks:
1.
Configure the global master-only IP address for the fxp0 management interface on
the same subnet as the four Routing Engines in the Virtual Chassis.
2. Configure a network path for the heartbeat connection.
This example uses a global static route to provide a path for member routers in the
same subnet to reach each other via a TCP/IP connection.
3. Configure the global master-only IP address for the fxp0 management interface as
the heartbeat address to establish the Virtual Chassis heartbeat connection.
4. (Optional) Configure a nondefault value for the Virtual Chassis heartbeat timeout
interval.
Topology
This example configures a heartbeat connection for an MX Series Virtual Chassis with
both member routers in the same subnet. For redundancy, each member router is
configured with two Virtual Chassis ports.
Table 23 on page 198 shows the hardware and software configuration settings for each
MX Series router in the Virtual Chassis.
Table 23: Components of the Sample MX Series Virtual Chassis with Member Routers in Same
Subnet
Router
Name
Hardware
Serial
Number
Member
ID
caelum
MX240 router with:
JN11026AFAFC
0
198
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member0-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member0-re1)
Role
Virtual Chassis
Ports
routing-engine
(master)
vcp-1/0/0
vcp-1/1/0
Subnet
10.4.0.0/16
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
Table 23: Components of the Sample MX Series Virtual Chassis with Member Routers in Same
Subnet (continued)
Router
Name
Hardware
Serial
Number
Member
ID
elnath
MX240 router with:
JN112C2FCAFC
1
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member1-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member1-re1)
Role
Virtual Chassis
Ports
routing-engine
(backup)
vcp-2/0/0
vcp-2/1/0
Subnet
10.4.0.0/16
Configuration
To configure a heartbeat connection in an MX Series Virtual Chassis with both member
routers in the same subnet, perform these tasks:
CLI Quick
Configuration
•
Configuring a Consistent Management IP Address for Each Routing Engine on page 200
•
Configuring a Static Route Between the Master and Backup Member Routers on page 202
•
Configuring the Heartbeat Address and Heartbeat Timeout on page 203
To quickly configure a heartbeat connection for a Virtual Chassis with both member
routers in the same subnet, copy the following commands and paste them into the router
terminal window:
[edit]
set groups member0-re0 interfaces fxp0 unit 0 family inet address 10.4.2.210/16
master-only
set groups member0-re1 interfaces fxp0 unit 0 family inet address 10.4.2.210/16
master-only
set groups member1-re0 interfaces fxp0 unit 0 family inet address 10.4.2.210/16
master-only
set groups member1-re1 interfaces fxp0 unit 0 family inet address 10.4.2.210/16
master-only
set groups global routing-options static route 10.4.0.0/16 next-hop 10.4.0.1
set groups global routing-options static route 10.4.0.0/16 retain
set groups global routing-options static route 10.4.0.0/16 no-readvertise
set virtual-chassis heartbeat-address 10.4.2.210
set virtual-chassis heartbeat-timeout 20
Copyright © 2017, Juniper Networks, Inc.
199
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Configuring a Consistent Management IP Address for Each Routing Engine
Step-by-Step
Procedure
In addition to configuring a unique IP address for the fxp0 management interface on each
Routing Engine when you first set up the Virtual Chassis, you must configure an additional
management IP address, known as the master-only address, to ensure consistent access
to the fxp0 management interface on the master Routing Engine in the Virtual Chassis
master router (VC-Mm, represented by member0-re0 in this example). You then use the
master-only address as the heartbeat address to establish the Virtual Chassis heartbeat
connection.
Because the Virtual Chassis member routers in this example both reside in the same
subnet (10.4.0.0), you can configure the same master-only address for each Routing
Engine. The master-only address is active only on the management interface for the
VC-Mm. During a switchover, the master-only address moves to the new Routing Engine
currently functioning as the VC-Mm.
To configure the master-only fxp0 IP address for each Routing Engine:
•
From the console on member 0, configure the same IP address for the fxp0
management interface on each Routing Engine.
{master:member0-re0}[edit]
user@caelum# set groups member0-re0 interfaces fxp0 unit 0 family inet address
10.4.2.210/16 master-only
user@caelum# set groups member0-re1 interfaces fxp0 unit 0 family inet address
10.4.2.210/16 master-only
user@caelum# set groups member1-re0 interfaces fxp0 unit 0 family inet address
10.4.2.210/16 master-only
user@caelum# set groups member1-re1 interfaces fxp0 unit 0 family inet address
10.4.2.210/16 master-only
Results
From the console on the Virtual Chassis master router, display the results of the
configuration for each configuration group. For brevity, portions of the configuration
unrelated to this procedure are replaced by an ellipsis (...).
For member0-re0:
{master:member0-re0}[edit]
user@caelum# show groups member0-re0
system {
host-name caelum;
backup-router 10.4.0.1 destination [ 172.16.0.0/12 ... 10.204.0.0/16 ];
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 10.4.2.100/16;
address 10.4.2.210/16 {
master-only;
}
}
200
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
}
}
}
For member0-re1:
{master:member0-re0}[edit]
user@caelum# show groups member0-re1
system {
host-name caelum1;
backup-router 10.4.0.1 destination [ 172.16.0.0/12 ... 10.204.0.0/16 ];
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 10.4.2.101/16;
address 10.4.2.210/16 {
master-only;
}
}
}
}
}
For member1-re0:
{master:member0-re0}[edit]
user@caelum# show groups member1-re0
system {
host-name elnath;
backup-router 10.4.0.1 destination [ 172.16.0.0/12 ... 10.204.0.0/16 ];
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 10.4.3.101/16;
address 10.4.2.210/16 {
master-only;
}
}
}
}
}
For member1-re1:
{master:member0-re0}[edit]
user@caelum# show groups member1-re1
system {
host-name elnath1;
backup-router 10.4.0.1 destination [ 172.16.0.0/12 ... 10.204.0.0/16 ];
}
interfaces {
fxp0 {
unit 0 {
Copyright © 2017, Juniper Networks, Inc.
201
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
family inet {
address 10.4.3.102/16;
address 10.4.2.210/16 {
master-only;
}
}
}
}
}
If you are done configuring the device, enter commit from configuration mode.
Configuring a Static Route Between the Master and Backup Member Routers
Step-by-Step
Procedure
You must configure a secure and reliable path between the master router and backup
router for the exchange of TCP/IP heartbeat packets. The heartbeat packets provide
critical information about the availability and health of each member router.
The route you create for the heartbeat connection must be independent of the Virtual
Chassis port links. Specifically, you must ensure that the master Routing Engine in the
Virtual Chassis backup router (VC-Bm) can make a TCP/IP connection to the master-only
IP address of the master Routing Engine in the Virtual Chassis master router (VC-Mm).
This examples creates a global static route between the member routers to configure
the heartbeat path. However, you can choose the method that best meets your needs
to configure the heartbeat path for member routers in the same subnet. For example,
you might use the member router’s default gateway for this purpose.
BEST PRACTICE: We recommend that you use the router management
interface (fxp0) as the heartbeat path. The management interface is generally
available earlier than the line card interfaces, and is typically connected to
a more secure network than the other interfaces.
To create a static route between the master and backup member routers:
•
From the console on member 0, configure a static route between the member
routers in subnet 10.4.0.0.
{master:member0-re0}[edit]
user@caelum# set groups global routing-options static route 10.4.0.0/16 next-hop
10.4.0.1
user@caelum# set groups global routing-options static route 10.4.0.0/16 retain
user@caelum# set groups global routing-options static route 10.4.0.0/16
no-readvertise
Results
Display the results of the configuration. For brevity, portions of the configuration unrelated
to this procedure are replaced by an ellipsis (...).
{master:member0-re0}[edit]
202
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
user@caelum# show groups global routing-options static
route 10.4.0.0/16 {
next-hop 10.4.0.1;
retain;
no-readvertise;
}
...
If you are done configuring the device, enter commit from configuration mode.
Configuring the Heartbeat Address and Heartbeat Timeout
Step-by-Step
Procedure
To establish the heartbeat connection in a two-member MX Series Virtual Chassis, you
must configure the IP address for the connection between the master and backup member
routers. To ensure consistent access to the master Routing Engine in the Virtual Chassis
master router (VC-Mm) regardless of which Routing Engine is currently active, you set
the heartbeat address to the previously configured global master-only IP address for the
fxp0 management interface.
Optionally, you can also configure a nondefault value for the heartbeat timeout interval.
The heartbeat timeout is the maximum time within which a Virtual Chassis member
router must respond to a heartbeat packet sent by the other member router. If you do
not explicitly configure the heartbeat timeout interval, the default value (2 seconds)
applies.
To configure the heartbeat address and heartbeat timeout:
1.
From the console on member 0, specify that you want to edit the Virtual Chassis
preprovisioned configuration.
{master:member0-re0}[edit]
user@caelum# edit virtual-chassis
2.
Configure the common master-only IP address for the fxp0 management interface
as the heartbeat address.
{master:member0-re0}[edit virtual-chassis]
user@caelum# set heartbeat-address 10.4.2.210
3.
(Optional) Configure a nondefault value for the heartbeat timeout interval.
{master:member0-re0}[edit virtual-chassis]
user@caelum# set heartbeat-timeout 20
Results
Display the results of the configuration.
{master:member0-re0}[edit]
user@caelum# show virtual-chassis
preprovisioned;
traceoptions {
file VCCP size 100m;
flag all;
Copyright © 2017, Juniper Networks, Inc.
203
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
}
heartbeat-address 10.4.2.210;
heartbeat-timeout 20;
member 0 {
role routing-engine;
serial-number JN11026AFAFC;
}
member 1 {
role routing-engine;
serial-number JN112C2FCAFC;
}
If you are done configuring the device, enter commit from configuration mode.
Verification
To confirm that the Virtual Chassis heartbeat connection is working properly, perform
these tasks:
•
Verifying the Virtual Chassis Heartbeat Connection on page 204
•
Verifying Use of the Heartbeat Connection During an Adjacency Split or
Disruption on page 205
•
Verifying Virtual Chassis Member Health from Heartbeat Statistics on page 205
Verifying the Virtual Chassis Heartbeat Connection
Purpose
Action
Verify that the heartbeat connection between the Virtual Chassis member routers is
properly configured and operational.
Display the state of one or both member routers when a heartbeat connection is
configured.
{master:member0-re0}
user@caelum> show virtual-chassis heartbeat
member0:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.2.210
10.4.3.101
Alive
2014-02-18 11:18:14 PST
member1:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.3.101
10.4.2.210
Alive
2014-02-18 11:18:15 PST
Meaning
204
For each member router, the command output displays the IP addresses of the local and
remote member routers that form the heartbeat connection. The value Alive in the State
field confirms that the master Routing Engine in the specified member router is connected
and has received a heartbeat response message. The Time field specifies the date and
time of the last connection state change.
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
Verifying Use of the Heartbeat Connection During an Adjacency Split or Disruption
Purpose
Action
Verify use of the heartbeat connection when an adjacency disruption or split is detected
in the Virtual Chassis.
Display the status of the member routers in the Virtual Chassis:
{master:member0-re0}
user@caelum> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 4806.94d6.2362
Member ID
0 (FPC
1 (FPC
Meaning
Status
0- 11) Heartbt
12- 23) Prsnt
Serial No
Model
Mastership
priority
Role
Neighbor List
ID Interface
JN11026AFAFC mx240
129
Master*
1
1
vcp-1/0/0
vcp-1/1/0
JN112C2FCAFC mx240
129
Backup
0
0
vcp-2/0/0
vcp-2/1/0
The Status field for member ID 0 displays Heartbt, which indicates that this member
router has used the heartbeat packet connection to maintain mastership roles during an
adjacency disruption or split in the Virtual Chassis configuration. The Status field for
member ID 1 displays Prsnt, which indicates that this member router is connected to the
Virtual Chassis.
If a router is not currently connected to the Virtual Chassis, the Status field displays
NotPrsnt.
Verifying Virtual Chassis Member Health from Heartbeat Statistics
Purpose
Use statistics collected by the heartbeat connection to verify the availability and health
of each Virtual Chassis member router. You can also use the show virtual-chassis heartbeat
detail command to determine the maximum latency and minimum latency in your network.
Copyright © 2017, Juniper Networks, Inc.
205
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Action
Display and review the statistics collected by the heartbeat connection.
{master:member0-re0}
user@caelum> show virtual-chassis heartbeat detail
member0:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.2.210
10.4.3.101
Alive
2014-02-18 11:18:14 PST
Heartbeat statistics
Heartbeats sent: 10079
Heartbeats received: 10079
Heartbeats lost/missed: 0
Last time sent: 2014-02-18 20:03:10 PST (00:00:00 ago)
Last time received: 2014-02-18 20:03:10 PST (00:00:00 ago)
Maximum latency (secs): 0
Minimum latency (secs): 0
member1:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.3.101
10.4.2.210
Alive
2014-02-18 11:18:15 PST
Heartbeat statistics
Heartbeats sent: 10083
Heartbeats received: 10083
Heartbeats lost/missed: 0
Last time sent: 2014-02-18 20:03:09 PST (00:00:01 ago)
Last time received: 2014-02-18 20:03:09 PST (00:00:01 ago)
Maximum latency (secs): 0
Minimum latency (secs): 0
Meaning
In this example, the number of heartbeat request messages sent (Heartbeats sent) equals
the number of heartbeat response messages received (Heartbeats received), with no
heartbeat messages lost (Heartbeats lost/missed). This indicates that both member
routers forming the heartbeat connection were available and operational. Any difference
between Heartbeats sent and Heartbeats received appears in the Heartbeats lost/missed
field.
The Maximum latency and Minimum latency fields measure the maximum and minimum
number of seconds that elapse on the local router between trasnmission of a heartbeat
request message and receipt of a heartbeat response message. In this example, the value
0 in the Maximum latency and Minimum latency fields indicates that there is no measurable
network delay caused by this operation. You can use the Maximum latency value to
determine whether you need to increase the heartbeat-timeout to a value higher than
the default (2 seconds). If the maximum latency in your network is too high to
accommodate a 2-second heartbeat-timeout value, increasing the heartbeat-timeout
interval enables you to account for network delay when a Virtual Chassis adjacency
disruption or split occurs.
206
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
Release History Table
Related
Documentation
Release
Description
14.1
Starting in Junos OS Release 14.1, you can configure a heartbeat connection
in an MX Series Virtual Chassis.
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Virtual Chassis Heartbeat Connection Overview on page 41
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Configuring a Consistent Management IP Address
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets
A heartbeat connection is an IP-based, bidirectional packet connection in an MX Series
Virtual Chassis between the Virtual Chassis master and backup routers. The heartbeat
packets exchanged over this connection provide critical information about the availability
and health of each member router. Starting in Junos OS Release 14.1, you can configure
a heartbeat connection in an MX Series Virtual Chassis.
This example describes how to configure a heartbeat connection in an MX Series Virtual
Chassis when the member routers reside in different subnets. For information about
configuring a heartbeat connection when the Virtual Chassis member routers reside in
the same subnet, see “Example: Determining Member Health Using an MX Series Virtual
Chassis Heartbeat Connection with Member Routers in the Same Subnet” on page 196.
•
Requirements on page 207
•
Overview on page 208
•
Configuration on page 210
•
Verification on page 219
Requirements
This example uses the following software and hardware components:
•
Junos OS Release 14.1 and later releases
•
One MX240 3D Universal Edge Router
•
One MX480 3D Universal Edge Router
This configuration example has been tested using the software release listed and is
assumed to work on all later releases.
Copyright © 2017, Juniper Networks, Inc.
207
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
BEST PRACTICE: We recommend that you use the commit synchronize
command to save any configuration changes to the Virtual Chassis. For an
MX Series Virtual Chassis, the force option is the default and only behavior
when you issue the commit synchronize command. Issuing the commit
synchronize command for an MX Series Virtual Chassis configuration has the
same effect as issuing the commit synchronize force command.
Before you configure a heartbeat connection for a Virtual Chassis:
•
Configure a Virtual Chassis consisting of two MX Series routers.
See “Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge
Routers Using a Virtual Chassis” on page 75
As part of the preprovisioned Virtual Chassis configuration shown in the configuration
example, you must create and apply the member0-re0, member0-re1, member1-re0,
and member1-re1 configuration groups for each member Routing Engine. Each
configuration group includes a unique IP address for the management Ethernet interface
(fxp0) on each Routing Engine.
NOTE: When you create the preprovisioned Virtual Chassis configuration
at the [edit virtual-chassis] hierarchy level, make sure you do not configure
the no-split-detection statement to disable detection of a split in the Virtual
Chassis. Using the no-split-detection statement is prohibited when you
configure a Virtual Chassis heartbeat connection, and doing so causes the
commit operation to fail.
•
Ensure TCP connectivity between the master Routing Engine in the Virtual Chassis
master router (VC-Mm) and the master Routing Engine in the Virtual Chassis backup
router (VC-Bm).
The Virtual Chassis heartbeat connection opens a proprietary TCP port numbered
33087 on the VC-Mm to listen for heartbeat messages. If your network design includes
firewalls or filters, make sure the network allows traffic between TCP port 33087 on
the VC-Mm and the dynamically allocated TCP port on the VC-Bm.
Overview
A heartbeat connection is an IP-based, bidirectional packet connection between the
master router and backup router in an MX Series Virtual Chassis. The member routers
forming the heartbeat connection exchange heartbeat packets that provide critical
information about the availability and health of each member router. During a disruption
or split in the Virtual Chassis configuration, the heartbeat connection prevents the member
routers from changing mastership roles unnecessarily, which can cause undesirable
results.
This example configures a heartbeat connection for an MX Series Virtual Chassis in which
the two member routers, each with dual Routing Engines installed, reside in different
208
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
subnets. Member router gladius resides in subnet 10.4.0.0/16 and is the global master
router for the Virtual Chassis (VC-M). Member router trefoil resides in subnet 10.5.0.0/16
and is the global backup router (VC-B) for the Virtual Chassis. The heartbeat connection
is configured between the master Routing Engine in gladius (represented by VC-Mm or
member0-re0) and the master Routing Engine in trefoil (represented by VC-Bm or
member1-re0).
Configuring a heartbeat connection for an MX Series Virtual Chassis when the member
routers reside in different subnets consists of the following tasks:
1.
Configure two master-only IP addresses for the fxp0 management interface: one for
the member routers in subnet 10.4.0.0, and a diffferent address for the member routers
in subnet 10.5.0.0.
2. Configure a network path for the heartbeat connection to ensure that both member
routers can reach each other’s networks.
This example creates static routes to both subnet 10.4.0.0 and subnet 10.5.0.0 on
each member router.
3. Configure the Virtual Chassis heartbeat address for each member Routing Engine to
cross-connect to the master-only IP address for the corresponding member Routing
Engine in the other subnet.
4. (Optional) Configure a nondefault value for the Virtual Chassis heartbeat timeout
interval.
To establish the heartbeat connection in a two-member MX Series Virtual Chassis, you
must configure the heartbeat address to establish the connection between the master
and backup member routers. To ensure consistent access to the master Routing Engine
in the Virtual Chassis master router (VC-Mm) regardless of which Routing Engine is
currently active, you set the heartbeat address to the previously configured master-only
IP address for the fxp0 management interface.
Because the Virtual Chassis member routers in this example are in different subnets, you
must configure a heartbeat address for each Routing Engine to enable a cross-connection
to the master-only IP address for the corresponding Routing Engine in the other subnet,
as shown in Table 24 on page 209:
Table 24: Heartbeat Cross-Connections for Member Routers in Different Subnets
Routing Engine
Subnet
Cross-connected Routing
Engine
Heartbeat Address
member0-re0
10.4.0.0/16
member1-re0
10.5.2.210
member0-re1
10.4.0.0/16
member1-re1
10.5.2.210
member1-re0
10.5.0.0/16
member0-re0
10.4.2.210
member1-re1
10.5.0.0/16
member0-re1
10.4.2.210
Copyright © 2017, Juniper Networks, Inc.
209
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Topology
This example configures a heartbeat connection for an MX Series Virtual Chassis with
member routers residing in different subnets. For redundancy, each member router is
configured with two Virtual Chassis ports.
Table 25 on page 210 shows the hardware and software configuration settings for each
MX Series router in the Virtual Chassis.
Table 25: Components of the Sample MX Series Virtual Chassis with Member Routers in Different
Subnets
Router
Name
Hardware
Serial
Number
Member
ID
gladius
MX240 router with:
JN10C7135AFC
JN115D117AFB
trefoil
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member0-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member0-re1)
MX480 router with:
•
Master RE-S-2000
Routing Engine in slot
0 (represented in
example as
member1-re0)
•
Backup RE-S-2000
Routing Engine in slot
1 (represented in
example as
member1-re1)
Role
Virtual Chassis
Ports
0
routing-engine
(master)
vcp-2/2/0
vcp-2/3/0
10.4.0.0/16
1
routing-engine
(backup)
vcp-2/0/0
vcp-5/2/0
10.5.0.0/16
Subnet
Configuration
To configure a heartbeat connection in an MX Series Virtual Chassis with member routers
in different subnets, perform these tasks:
CLI Quick
Configuration
210
•
Configuring a Consistent Management IP Address for Each Routing Engine on page 212
•
Configuring Static Routes for Both Subnets on Each Routing Engine on page 214
•
Configuring the Heartbeat Address and Heartbeat Timeout on page 217
To quickly configure a heartbeat connection for a Virtual Chassis with with member
routers in different subnets, copy the following commands and paste them into the router
terminal window:
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
[edit]
set groups member0-re0 interfaces fxp0 unit 0 family inet address 10.4.2.210/16
master-only
set groups member0-re1 interfaces fxp0 unit 0 family inet address 10.4.2.210/16
master-only
set groups member1-re0 interfaces fxp0 unit 0 family inet address 10.5.2.210/16
master-only
set groups member1-re1 interfaces fxp0 unit 0 family inet address 10.5.2.210/16
master-only
set groups member0-re0 routing-options static route 10.4.0.0/16 next-hop 10.4.0.1
set groups member0-re0 routing-options static route 10.4.0.0/16 retain
set groups member0-re0 routing-options static route 10.4.0.0/16 no-readvertise
set groups member0-re0 routing-options static route 10.5.0.0/16 next-hop 10.4.0.1
set groups member0-re0 routing-options static route 10.5.0.0/16 retain
set groups member0-re0 routing-options static route 10.5.0.0/16 no-readvertise
set groups member0-re1 routing-options static route 10.4.0.0/16 next-hop 10.4.0.1
set groups member0-re1 routing-options static route 10.4.0.0/16 retain
set groups member0-re1 routing-options static route 10.4.0.0/16 no-readvertise
set groups member0-re1 routing-options static route 10.5.0.0/16 next-hop 10.4.0.1
set groups member0-re1 routing-options static route 10.5.0.0/16 retain
set groups member0-re1 routing-options static route 10.5.0.0/16 no-readvertise
set groups member1-re0 routing-options static route 10.5.0.0/16 next-hop 10.5.0.1
set groups member1-re0 routing-options static route 10.5.0.0/16 retain
set groups member1-re0 routing-options static route 10.5.0.0/16 no-readvertise
set groups member1-re0 routing-options static route 10.4.0.0/16 next-hop 10.5.0.1
set groups member1-re0 routing-options static route 10.4.0.0/16 retain
set groups member1-re0 routing-options static route 10.4.0.0/16 no-readvertise
set groups member1-re1 routing-options static route 10.5.0.0/16 next-hop 10.5.0.1
set groups member1-re1 routing-options static route 10.5.0.0/16 retain
set groups member1-re1 routing-options static route 10.5.0.0/16 no-readvertise
set groups member1-re1 routing-options static route 10.4.0.0/16 next-hop 10.5.0.1
set groups member1-re1 routing-options static route 10.4.0.0/16 retain
set groups member1-re1 routing-options static route 10.4.0.0/16 no-readvertise
set groups member0-re0 virtual-chassis heartbeat-address 10.5.2.210
set groups member0-re1 virtual-chassis heartbeat-address 10.5.2.210
set groups member1-re0 virtual-chassis heartbeat-address 10.4.2.210
set groups member1-re1 virtual-chassis heartbeat-address 10.4.2.210
set virtual-chassis heartbeat-timeout 10
Copyright © 2017, Juniper Networks, Inc.
211
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Configuring a Consistent Management IP Address for Each Routing Engine
Step-by-Step
Procedure
In addition to configuring a unique IP address for the fxp0 management interface on each
Routing Engine when you first set up the Virtual Chassis, you must configure additional
management IP addresses, known as the master-only address, to ensure consistent
access to the fxp0 management interface on the master Routing Engine in the Virtual
Chassis master router (VC-Mm). The master-only address is active only on the
management interface for the VC-Mm. During a switchover, the master-only address
moves to the new Routing Engine currently functioning as the VC-Mm.
Because the Virtual Chassis master router and backup router in this example reside in
different subnets, you must configure two different master-only IP addresses: one for
the Routing Engines in subnet 10.4.0.0/16 (member0-re0 and member0-re1), and one for
the Routing Engines in subnet 10.5.0.0/16 (member1-re0 and member1-re1). You then
configure these master-only addresses as the subnet-specific heartbeat addresses to
establish the heartbeat connection. For more information about the cross-connections
in this example, see Table 24 on page 209.
To configure the master-only fxp0 IP address for each Routing Engine:
1.
From the console on member 0, configure the IP address for the fxp0 management
interface for the Routing Engines in subnet 10.4.0.0/16.
{master:member0-re0}[edit]
user@gladius# set groups member0-re0 interfaces fxp0 unit 0 family inet address
10.4.2.210/16 master-only
user@gladius# set groups member0-re1 interfaces fxp0 unit 0 family inet address
10.4.2.210/16 master-only
2.
From the console on member 0, configure the IP address for the fxp0 management
interface for the Routing Engines in subnet 10.5.0.0/16.
{master:member0-re0}[edit]
user@gladius# set groups member1-re0 interfaces fxp0 unit 0 family inet address
10.5.2.210/16 master-only
user@gladius# set groups member1-re1 interfaces fxp0 unit 0 family inet address
10.5.2.210/16 master-only
Results
From the console on the Virtual Chassis master router, display the results of the
configuration. For brevity, portions of the configuration unrelated to this procedure are
replaced by an ellipsis (...).
For member0-re0:
{master:member0-re0}[edit]
user@gladius# show groups member0-re0
system {
host-name gladius;
backup-router 10.4.0.1 destination [ 172.16.0.0/12 ... 10.204.0.0/16 ];
}
interfaces {
212
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
fxp0 {
unit 0 {
family inet {
address 10.4.2.100/16;
address 10.4.2.210/16 {
master-only;
}
}
}
}
}
For member0-re1:
{master:member0-re0}[edit]
user@gladius# show groups member0-re1
system {
host-name gladius1;
backup-router 10.4.0.1 destination [ 172.16.0.0/12 ... 10.204.0.0/16 ];
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 10.4.2.101/16;
address 10.4.2.210/16 {
master-only;
}
}
}
}
}
For member1-re0:
{master:member0-re0}[edit]
user@gladius# show groups member1-re0
system {
host-name trefoil;
backup-router 10.5.0.1 destination [ 172.16.0.0/12 ... 10.204.0.0/16 ];
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 10.5.3.101/16;
address 10.5.2.210/16 {
master-only;
}
}
}
}
}
For member1-re1:
{master:member0-re0}[edit]
Copyright © 2017, Juniper Networks, Inc.
213
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
user@gladius# show groups member1-re1
system {
host-name trefoil1;
backup-router 10.5.0.1 destination [ 172.16.0.0/12 ... 10.204.0.0/16 ];
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 10.5.3.102/16;
address 10.5.2.210/16 {
master-only;
}
}
}
}
}
If you are done configuring the device, enter commit from configuration mode.
Configuring Static Routes for Both Subnets on Each Routing Engine
Step-by-Step
Procedure
You must configure secure and reliable routes for subnets 10.4.0.0/16 and 10.5.0.0/16
on each Routing Engine for the exchange of TCP/IP heartbeat packets. The heartbeat
packets provide critical information about the availability and health of each member
router.
The routes you configure for the heartbeat connection must be independent of the Virtual
Chassis port links. Specifically, you must ensure that the master Routing Engine in the
Virtual Chassis backup router (VC-Bm) can make a TCP/IP connection to the master-only
IP address of the master Routing Engine in the Virtual Chassis master router (VC-Mm).
This examples creates static routes to both subnets on each member Routing Engine to
configure the heartbeat path. However, you can choose the method that best meets your
needs to configure the heartbeat path for member routers in different subnets.
BEST PRACTICE: We recommend that you use the router management
interface (fxp0) as the heartbeat path. The management interface is generally
available earlier than the line card interfaces, and is typically connected to
a more secure network than the other interfaces.
To create static routes for subnets 10.4.0.0/16 and 10.5.0.0/16 on each Routing Engine:
1.
Log in to the console on member 0 (Virtual Chassis master router).
2.
Configure the static routes for member0-re0.
{master:member0-re0}[edit]
user@gladius# set groups member0-re0 routing-options static route 10.4.0.0/16
next-hop 10.4.0.1
214
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
user@gladius# set groups member0-re0 routing-options static route 10.4.0.0/16
retain
user@gladius# set groups member0-re0 routing-options static route 10.4.0.0/16
no-readvertise
user@gladius# set groups member0-re0 routing-options static route 10.5.0.0/16
next-hop 10.4.0.1
user@gladius# set groups member0-re0 routing-options static route 10.5.0.0/16
retain
user@gladius# set groups member0-re0 routing-options static route 10.5.0.0/16
no-readvertise
3.
Configure the static routes for member0-re1.
{master:member0-re0}[edit]
user@gladius# set groups member0-re1 routing-options static route 10.4.0.0/16
next-hop 10.4.0.1
user@gladius# set groups member0-re1 routing-options static route 10.4.0.0/16
retain
user@gladius# set groups member0-re1 routing-options static route 10.4.0.0/16
no-readvertise
user@gladius# set groups member0-re1 routing-options static route 10.5.0.0/16
next-hop 10.4.0.1
user@gladius# set groups member0-re1 routing-options static route 10.5.0.0/16
retain
user@gladius# set groups member0-re1 routing-options static route 10.5.0.0/16
no-readvertise
4.
Configure the static routes for member1-re0.
{master:member0-re0}[edit]
user@gladius# set groups member1-re0 routing-options static route 10.5.0.0/16
next-hop 10.5.0.1
user@gladius# set groups member1-re0 routing-options static route 10.5.0.0/16
retain
user@gladius# set groups member1-re0 routing-options static route 10.5.0.0/16
no-readvertise
user@gladius# set groups member1-re0 routing-options static route 10.4.0.0/16
next-hop 10.5.0.1
user@gladius# set groups member1-re0 routing-options static route 10.4.0.0/16
retain
user@gladius# set groups member1-re0 routing-options static route 10.4.0.0/16
no-readvertise
5.
Configure the static routes for member1-re1.
{master:member0-re0}[edit]
user@gladius# set groups member1-re1 routing-options static route 10.5.0.0/16
next-hop 10.5.0.1
user@gladius# set groups member1-re1 routing-options static route 10.5.0.0/16
retain
user@gladius# set groups member1-re1 routing-options static route 10.5.0.0/16
no-readvertise
user@gladius# set groups member1-re1 routing-options static route 10.4.0.0/16
next-hop 10.5.0.1
Copyright © 2017, Juniper Networks, Inc.
215
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
user@gladius# set groups member1-re1 routing-options static route 10.4.0.0/16
retain
user@gladius# set groups member1-re1 routing-options static route 10.4.0.0/16
no-readvertise
Results
Display the results of the configuration. For brevity, portions of the configuration unrelated
to this procedure are replaced by an ellipsis (...).
For member0-re0:
{master:member0-re0}[edit]
user@gladius# show groups member0-re0 routing-options static
route 10.4.0.0/16 {
next-hop 10.4.0.1;
retain;
no-readvertise;
}
route 10.5.0.0/16 {
next-hop 10.4.0.1;
retain;
no-readvertise;
}
...
For member0-re1:
{master:member0-re0}[edit]
user@gladius# show groups member0-re1 routing-options static
route 10.4.0.0/16 {
next-hop 10.4.0.1;
retain;
no-readvertise;
}
route 10.5.0.0/16 {
next-hop 10.4.0.1;
retain;
no-readvertise;
}
...
For member1-re0:
{master:member0-re0}[edit]
user@gladius# show groups member1-re0 routing-options static
route 10.5.0.0/16 {
next-hop 10.5.0.1;
retain;
no-readvertise;
}
route 10.4.0.0/16 {
next-hop 10.5.0.1;
retain;
no-readvertise;
}
...
216
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
For member1-re1:
{master:member0-re0}[edit]
user@gladius# show groups member1-re1 routing-options static
route 10.5.0.0/16 {
next-hop 10.5.0.1;
retain;
no-readvertise;
}
route 10.4.0.0/16 {
next-hop 10.5.0.1;
retain;
no-readvertise;
}
...
If you are done configuring the device, enter commit from configuration mode.
Configuring the Heartbeat Address and Heartbeat Timeout
Step-by-Step
Procedure
To enable cross-connection between Virtual Chassis member routers in different subnets,
you configure 10.5.2.210, which is the master-only IP address for the Routing Engines in
subnet 10.5.0.0/16, as the heartbeat address for the Routing Engines in subnet 10.4.0.0/16
(member0-re0 and member0-re1). Conversely, you configure 10.4.2.210, which is the
master-only IP address for the Routing Engines in subnet 10.4.0.0/16, as the heartbeat
address for the Routing Engines in subnet 10.5.0.0/16 (member1-re0 and member1-re1).
For more information about the cross-connections in this example, see
Table 24 on page 209.
Optionally, you can also configure a nondefault value for the heartbeat timeout interval.
The heartbeat timeout is the maximum time within which a Virtual Chassis member
router must respond to a heartbeat packet sent by the other member router. If you do
not explicitly configure the heartbeat timeout interval, the default value (2 seconds)
applies.
To configure the heartbeat address and heartbeat timeout:
1.
Log in to the console on member 0 (Virtual Chassis master router).
2.
Configure the heartbeat address for each Routing Engine.
{master:member0-re0}[edit]
user@gladius# set groups member0-re0 virtual-chassis heartbeat-address 10.5.2.210
user@gladius# set groups member0-re1 virtual-chassis heartbeat-address 10.5.2.210
user@gladius# set groups member1-re0 virtual-chassis heartbeat-address 10.4.2.210
user@gladius# set groups member1-re1 virtual-chassis heartbeat-address 10.4.2.210
3.
(Optional) Configure a nondefault value for the heartbeat timeout interval.
{master:member0-re0}[edit]
user@gladius# set virtual-chassis heartbeat-timeout 10
Copyright © 2017, Juniper Networks, Inc.
217
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Results
Display the results of the configuration.
For member0-re0:
{master:member0-re0}[edit]
user@gladius# show groups member0-re0 virtual-chassis
preprovisioned;
traceoptions {
file VCCP size 100m;
flag all;
}
heartbeat-address 10.5.2.210;
heartbeat-timeout 10;
member 0 {
role routing-engine;
serial-number JN10C7135AFC;
}
member 1 {
role routing-engine;
serial-number JN115D117AFB;
}
For member0-re1:
{master:member0-re0}[edit]
user@gladius# show groups member0-re1 virtual-chassis
preprovisioned;
traceoptions {
file VCCP size 100m;
flag all;
}
heartbeat-address 10.5.2.210;
heartbeat-timeout 10;
member 0 {
role routing-engine;
serial-number JN10C7135AFC;
}
member 1 {
role routing-engine;
serial-number JN115D117AFB;
}
For member1-re0:
{master:member0-re0}[edit]
user@gladius# show groups member1-re0 virtual-chassis
preprovisioned;
traceoptions {
file VCCP size 100m;
flag all;
}
heartbeat-address 10.4.2.210;
heartbeat-timeout 10;
member 0 {
role routing-engine;
serial-number JN10C7135AFC;
}
218
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
member 1 {
role routing-engine;
serial-number JN115D117AFB;
}
For member1-re1:
{master:member0-re0}[edit]
user@gladius# show groups member1-re1 virtual-chassis
preprovisioned;
traceoptions {
file VCCP size 100m;
flag all;
}
heartbeat-address 10.4.2.210;
heartbeat-timeout 10;
member 0 {
role routing-engine;
serial-number JN10C7135AFC;
}
member 1 {
role routing-engine;
serial-number JN115D117AFB;
}
If you are done configuring the device, enter commit from configuration mode.
Verification
To confirm that the Virtual Chassis heartbeat connection is working properly, perform
these tasks:
•
Verifying the Virtual Chassis Heartbeat Connection on page 219
•
Verifying Use of the Heartbeat Connection During an Adjacency Split or
Disruption on page 220
•
Verifying Virtual Chassis Member Health from Heartbeat Statistics on page 221
Verifying the Virtual Chassis Heartbeat Connection
Purpose
Verify that the heartbeat connection between the Virtual Chassis member routers is
properly configured and operational.
Copyright © 2017, Juniper Networks, Inc.
219
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Action
Display the state of one or both member routers when a heartbeat connection is
configured.
{master:member0-re0}
user@gladius> show virtual-chassis heartbeat
member0:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.2.210
10.5.3.101
Alive
2014-03-18 10:18:14 PST
member1:
-------------------------------------------------------------------------Local
Remote
State
Time
10.5.3.101
10.4.2.210
Alive
2014-03-18 10:18:15 PST
Meaning
For each member router, the command output displays the IP addresses of the local and
remote member routers that form the heartbeat connection. The value Alive in the State
field confirms that the master Routing Engine in the specified member router is connected
and has received a heartbeat response message. The Time field specifies the date and
time of the last connection state change.
Verifying Use of the Heartbeat Connection During an Adjacency Split or Disruption
Purpose
Action
Verify use of the heartbeat connection when an adjacency disruption or split is detected
in the Virtual Chassis.
Display the status of the member routers in the Virtual Chassis:
{master:member0-re0}
user@gladius> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: a5b6.be0c.9525
Member ID
0 (FPC
1 (FPC
Meaning
220
Status
0- 11) Heartbt
12- 23) Prsnt
Serial No
Model
Mastership
priority
Role
Neighbor List
ID Interface
JN10C7135AFC mx240
129
Master*
1
1
vcp-2/2/0
vcp-2/3/0
JN115D117AFB mx480
129
Backup
0
0
vcp-2/0/0
vcp-5/2/0
The Status field for member ID 0 displays Heartbt, which indicates that this member
router has used the heartbeat packet connection to maintain mastership roles during an
adjacency disruption or split in the Virtual Chassis configuration. The Status field for
member ID 1 displays Prsnt, which indicates that this member router is connected to the
Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Monitoring an MX Series Virtual Chassis
If a router is not currently connected to the Virtual Chassis, the Status field displays
NotPrsnt.
Verifying Virtual Chassis Member Health from Heartbeat Statistics
Purpose
Action
Use statistics collected by the heartbeat connection to verify the availability and health
of each Virtual Chassis member router. You can also use the show virtual-chassis heartbeat
detail command to determine the maximum latency and minimum latency in your network.
Display and review the statistics collected by the heartbeat connection.
{master:member0-re0}
user@gladius> show virtual-chassis heartbeat detail
member0:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.2.210
10.5.3.101
Alive
2014-03-18 10:18:14 PST
Heartbeat statistics
Heartbeats sent: 10079
Heartbeats received: 10079
Heartbeats lost/missed: 0
Last time sent: 2014-03-18 20:03:10 PST (00:00:00 ago)
Last time received: 2014-03-18 20:03:10 PST (00:00:00 ago)
Maximum latency (secs): 0
Minimum latency (secs): 0
member1:
-------------------------------------------------------------------------Local
Remote
State
Time
10.5.3.101
10.4.2.210
Alive
2014-03-18 10:18:15 PST
Heartbeat statistics
Heartbeats sent: 10083
Heartbeats received: 10083
Heartbeats lost/missed: 0
Last time sent: 2014-02-18 20:03:09 PST (00:00:01 ago)
Last time received: 2014-02-18 20:03:09 PST (00:00:01 ago)
Maximum latency (secs): 0
Minimum latency (secs): 0
Meaning
In this example, the number of heartbeat request messages sent (Heartbeats sent) equals
the number of heartbeat response messages received (Heartbeats received), with no
heartbeat messages lost (Heartbeats lost/missed). This indicates that both member
routers forming the heartbeat connection are available and operational. Any difference
between Heartbeats sent and Heartbeats received appears in the Heartbeats lost/missed
field.
The Maximum latency and Minimum latency fields measure the maximum and minimum
number of seconds that elapse on the local router between transmission of a heartbeat
request message and receipt of a heartbeat response message. In this example, the value
0 in the Maximum latency and Minimum latency fields indicates that there is no measurable
Copyright © 2017, Juniper Networks, Inc.
221
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
network delay caused by this operation. You can use the Maximum latency value to
determine whether you need to increase the heartbeat-timeout to a value higher than
the default (2 seconds). If the maximum latency in your network is too high to
accommodate a 2-second heartbeat-timeout value, increasing the heartbeat-timeout
interval enables you to account for network delay when a Virtual Chassis adjacency
disruption or split occurs.
Release History Table
Related
Documentation
222
Release
Description
14.1
Starting in Junos OS Release 14.1, you can configure a heartbeat connection
in an MX Series Virtual Chassis.
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Virtual Chassis Heartbeat Connection Overview on page 41
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Configuring a Consistent Management IP Address
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 11
Tracing Virtual Chassis Operations for
Troubleshooting Purposes
•
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers on page 224
•
Configuring the Name of the Virtual Chassis Trace Log File on page 225
•
Configuring Characteristics of the Virtual Chassis Trace Log File on page 225
•
Configuring Access to the Virtual Chassis Trace Log File on page 226
•
Using Regular Expressions to Refine the Output of the Virtual Chassis Trace Log
File on page 227
•
Configuring the Virtual Chassis Operations to Trace on page 228
Copyright © 2017, Juniper Networks, Inc.
223
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers
The Junos OS trace feature tracks Virtual Chassis operations and records events in a log
file. The error descriptions captured in the log file provide detailed information to help
you solve problems.
By default, tracing is disabled. When you enable the tracing operation on the router to
be configured as the master (also referred to as the protocol master) of an MX Series
Virtual Chassis, the default tracing behavior is as follows:
1.
Important events are logged in a file with the name you specify in the /var/log directory.
You cannot change the directory (/var/log) in which trace files are located.
2. When a trace file named trace-file reaches its maximum size, it is renamed trace-file.0,
then trace-file.1, and so on, until the maximum number of trace files is reached. Then
the oldest trace file is overwritten.
You can optionally specify the maximum number of trace files to be from 2 through
1000. You can also configure the maximum file size to be from 10 KB through 1 gigabyte
(GB). (For more information about how log files are created, see the System Log
Explorer.)
By default, only the user who configures the tracing operation can access log files.
You can optionally configure read-only access for all users.
To configure tracing of MX Series Virtual Chassis operations:
1.
Configure a filename for the trace log.
See “Configuring the Name of the Virtual Chassis Trace Log File” on page 225.
2. (Optional) Configure characteristics of the trace log file.
See “Configuring Characteristics of the Virtual Chassis Trace Log File” on page 225.
3. (Optional) Configure user access to the trace log file.
See “Configuring Access to the Virtual Chassis Trace Log File” on page 226.
4. (Optional) Refine the output of the trace log file.
See “Using Regular Expressions to Refine the Output of the Virtual Chassis Trace Log
File” on page 227.
5. Configure flags to specify the Virtual Chassis operations that you want to trace.
See “Configuring the Virtual Chassis Operations to Trace” on page 228.
Related
Documentation
224
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
Copyright © 2017, Juniper Networks, Inc.
Chapter 11: Tracing Virtual Chassis Operations for Troubleshooting Purposes
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Configuring the Name of the Virtual Chassis Trace Log File
To trace operations for a Virtual Chassis, you must configure the name of the trace log
file that the software saves in the /var/log directory.
To configure the filename for tracing Virtual Chassis operations:
•
On the device to be designated as the master of the Virtual Chassis, specify the name
of the trace log file.
[edit virtual-chassis]
user@host# set traceoptions file filename
Related
Documentation
•
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers on page 224
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Configuring Characteristics of the Virtual Chassis Trace Log File
You can optionally configure the following characteristics of the trace log file for a Virtual
Chassis:
•
Maximum number of trace files—When a trace file named trace-file reaches its
maximum size, it is renamed trace-file.0, then trace-file.1, and so on, until the maximum
number of trace files is reached. Then the oldest trace file is overwritten. You can
optionally specify the maximum number of trace files to be from 2 through 1000. If
you specify a maximum number of files with the files option, you must also specify a
maximum file size with the size option.
•
Maximum trace file size—You can configure the maximum trace file size to be from 10
KB through 1 gigabyte (GB) If you specify a maximum file size with the size option, you
must also specify a maximum number of files with the files option.
•
Timestamp—By default, timestamp information is placed at the beginning of each line
of trace output. You can optionally prevent placement of a timestamp on any trace
log file.
•
Appending or replacing the trace file—By default, the router or switch appends new
information to an existing trace file. You can optionally specify that the router or switch
replace an exisiting trace file instead of appending information to it.
To configure the maximum number and maximum size of trace files:
•
On the router or switch to be designated as the master of the Virtual Chassis, specify
the maximum number and maximum size of the trace file.
Copyright © 2017, Juniper Networks, Inc.
225
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
[edit virtual-chassis]
user@host# set traceoptions file filename files number size maximum-file-size
For example, to set the maximum number of files to 20 and the maximum file size to
2 MB for a trace file named vccp:
[edit virtual-chassis]
user@host# set traceoptions file vccp files 20 size 2097152
When the vccp trace file for this example reaches 2 MB, vccp is renamed vccp.0, and
a new file named vccp is created. When the new vccp file reaches 2 MB, vccp.0 is
renamed vccp.1 and vccp is renamed vccp.0. This process repeats until there are 20
trace files. Then the oldest file (vccp.19) is overwritten by the newest file (vccp.0).
To prevent the router or switch from the placing a timestamp on the trace log file:
•
On the router or switch to be designated as the master of the Virtual Chassis, specify
that a timestamp not appear on the trace log file:
[edit virtual-chassis]
user@host# set traceoptions file filename no-stamp
To replace an exisiting trace file instead of appending information to it:
•
On the router or switch to be designated as the master of the Virtual Chassis, specify
that the router or switch replaces an existing trace file:
[edit virtual-chassis]
user@host# set traceoptions file filename replace
Related
Documentation
•
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers on page 224
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Configuring Access to the Virtual Chassis Trace Log File
By default, only the user who configures the tracing operation can access the log files.
You can enable all users to read the log file, and you can explicitly set the default behavior
of the log file.
To configure access to the trace log file for all users:
•
On the router or switch to be designated as the master of the Virtual Chassis, specify
that all users can read the trace log file.
[edit virtual-chassis]
user@host# set traceoptions file filename world-readable
226
Copyright © 2017, Juniper Networks, Inc.
Chapter 11: Tracing Virtual Chassis Operations for Troubleshooting Purposes
To explicitly set the default behavior to enable access to the trace log file only for the
user who configured tracing:
•
On the router or switch to be designated as the master of the Virtual Chassis, specify
that only the user who configured tracing can read the trace log file.
[edit virtual-chassis]
user@host# set traceoptions file filename no-world-readable
Related
Documentation
•
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers on page 224
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Using Regular Expressions to Refine the Output of the Virtual Chassis Trace Log File
By default, the trace operation output includes all lines relevant to the logged events.
You can refine the output of the trace log file for a Virtual Chassis by including regular
expressions to be matched.
To refine the output of the trace log file:
•
On the router or switch to be designated as the master of the Virtual Chassis, configure
a regular expression to be matched.
[edit virtual-chassis]
user@host# set traceoptions file filename match regular-expression
Related
Documentation
•
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers on page 224
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
227
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Configuring the Virtual Chassis Operations to Trace
By default, the router or switch logs only important events. You can specify which
operations to trace for a Virtual Chassis by including specific tracing flags when you
configure tracing. Table 26 on page 228 describes the flags that you can include.
Table 26: Tracing Flags for Virtual Chassis
Flag
Description
all
Trace all operations.
auto-configuration
Trace Virtual Chassis ports that have been automatically
configured.
csn
Trace Virtual Chassis complete sequence number (CSN)
packets.
error
Trace Virtual Chassis errored packets.
graceful-restart
Trace Virtual Chassis graceful restart events.
hello
Trace Virtual Chassis hello packets.
krt
Trace Virtual Chassis kernel routing table (KRT) events.
lsp
Trace Virtual Chassis link-state packets.
lsp-generation
Trace Virtual Chassis link-state packet generation.
me
Trace Virtual Chassis mastership election (ME) events.
normal
Trace normal events.
packets
Trace Virtual Chassis packets.
parse
Trace reading of the configuration.
psn
Trace partial sequence number (PSN) packets.
route
Trace Virtual Chassis routing information.
spf
Trace Virtual Chassis shortest-path-first (SPF) events.
state
Trace Virtual Chassis state transitions.
task
Trace Virtual Chassis task operations.
To configure the flags for the Virtual Chassis operations to be logged:
228
Copyright © 2017, Juniper Networks, Inc.
Chapter 11: Tracing Virtual Chassis Operations for Troubleshooting Purposes
1.
Specify the tracing flag that represents the operation you want to trace.
[edit virtual-chassis]
user@host# set traceoptions flag flag
2. (Optional) Specify one or more of the following additional tracing options for the
specified flag:
•
To generate detailed trace output, use the detail option.
•
To disable a particular flag, use the disable option.
•
To trace received packets, use the receive option.
•
To trace transmitted packets, use the send option.
For example, to generate detailed trace output for Virtual Chassis mastership election
events in received packets:
[edit virtual-chassis]
user@host# set traceoptions flag me detail receive
Related
Documentation
•
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers on page 224
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
229
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
230
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 12
Configuration Statements
•
aggregated-ether-options on page 232
•
heartbeat-address (MX Series Virtual Chassis) on page 234
•
heartbeat-timeout (MX Series Virtual Chassis) on page 235
•
heartbeat-tos (MX Series Virtual Chassis) on page 236
•
locality-bias (MX Series Virtual Chassis) on page 237
•
logical-interface-chassis-redundancy (MX Series Virtual Chassis) on page 238
•
logical-interface-fpc-redundancy (Aggregated Ethernet Subscriber
Interfaces) on page 238
•
member (MX Series Virtual Chassis) on page 239
•
network-services on page 240
•
no-split-detection (MX Series Virtual Chassis) on page 241
•
preprovisioned (MX Series Virtual Chassis) on page 242
•
role (MX Series Virtual Chassis) on page 243
•
sampling-instance on page 244
•
serial-number (MX Series Virtual Chassis) on page 245
•
targeted-distribution (Static Interfaces over Aggregated Ethernet) on page 246
•
traceoptions (MX Series Virtual Chassis) on page 247
•
virtual-chassis (MX Series Virtual Chassis) on page 249
Copyright © 2017, Juniper Networks, Inc.
231
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
aggregated-ether-options
Syntax
232
aggregated-ether-options {
ethernet-switch-profile {
ethernet-policer-profile {
input-priority-map {
ieee802.1p premium [ values ];
}
output-priority-map {
classifier {
premium {
forwarding-class class-name {
loss-priority (high | low);
}
}
}
}
policer cos-policer-name {
aggregate {
bandwidth-limit bps;
burst-size-limit bytes;
}
premium {
bandwidth-limit bps;
burst-size-limit bytes;
}
}
}
(mac-learn-enable | no-mac-learn-enable);
}
(flow-control | no-flow-control);
lacp {
(active | passive);
link-protection {
disable;
(revertive | non-revertive);
periodic interval;
system-priority priority;
system-id system-id;
}
link-protection;
load-balance;
link-speed speed;
logical-interface-chassis-redundancy;
logical-interface-fpc-redundancy;
(loopback | no-loopback);
minimum-links number;
rebalance-periodic time hour:minute <interval hours>;
source-address-filter {
mac-address;
(source-filtering | no-source-filtering);
}
}
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
Hierarchy Level
Release Information
Description
[edit interfaces aex]
Statement introduced before Junos OS Release 7.4.
Configure aggregated Ethernet-specific interface properties.
The remaining statements are explained separately. See CLI Explorer.
Required Privilege
Level
Related
Documentation
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
•
Ethernet Interfaces Overview
Copyright © 2017, Juniper Networks, Inc.
233
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
heartbeat-address (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
heartbeat-address (ip-address | ipv6-address);
[edit virtual-chassis]
Statement introduced in Junos OS Release 14.1.
Configure an IPv4 address or IPv6 address used to create an IP-based packet connection,
known as a heartbeat connection, between the master router and backup router in an
MX Series Virtual Chassis. To ensure consistent access to the master Routing Engine in
the Virtual Chassis master router (VC-Mm) regardless of which Routing Engine is active,
you must configure the address for the management Ethernet interface (fxp0) with the
master-only statement at the [edit groups] hierarchy level.
NOTE: The heartbeat-address statement and the no-split-detection statement
at the [edit virtual-chassis] hierarchy level are mutually exclusive. As a result,
the software prevents you from configuring both heartbeat-address and
no-split-detection at the same time. If you attempt to do so, the software
displays an error message and causes the commit operation to fail.
Options
ip-address—IPv4 master-only address for the fxp0 management interface.
ipv6-address—IPv6 master-only address for the fxp0 management interface.
Required Privilege
Level
Related
Documentation
234
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
heartbeat-timeout (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
heartbeat-timeout seconds;
[edit virtual-chassis]
Statement introduced in Junos OS Release 14.1.
Configure the maximum time period within which a Virtual Chassis member router must
respond to a heartbeat packet sent by the other member router. When an adjacency
disruption or split is detected in the Virtual Chassis configuration, each member router
sends a single heartbeat packet to the other member router to determine whether that
router is still operating and able to respond. If the other member router responds to the
heartbeat packet within the configured or default timeout period, the heartbeat connection
helps prevent the member routers from changing mastership roles, which can cause
undesirable results.
NOTE: Both member routers forming the heartbeat connection must be
assigned the routing-engine role in the preprovisioned Virtual Chassis
configuration. The routing-engine role makes the router eligible to function
as either the master router or backup router of the Virtual Chassis.
Options
seconds—Number of seconds within which a Virtual Chassis member router must respond
to a heartbeat packet.
Range: 1 through 60 seconds
Default: 2 seconds
Required Privilege
Level
Related
Documentation
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
Copyright © 2017, Juniper Networks, Inc.
235
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
heartbeat-tos (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
heartbeat-tos value;
[edit virtual-chassis]
Statement introduced in Junos OS Release 15.1.
Configure a network-specific value for the header field that defines either the type of
service (ToS), traffic class (TC), or differential services (DS) octet that is transmitted in
the header of a heartbeat packet.. This field is a single octet that ensures preferential
delivery of heartbeat packets between Virtual Chassis member routers in a congested
network. You can set the IP precedence portion of the ToS header field or the
differentiated services code point (DSCP) in the DS header field in accordance with your
network. When you configure a heartbeat-tos value, the software uses this octet value
in the IP header for all generated Virtual Chassis heartbeat packets.
Configuring the heartbeat-tos Virtual Chassis heartbeat packets is particularly useful in
congested networks or in networks with high bandwidth demands. For example, setting
the appropriate heartbeat-tos value for your network design enables you to prioritize the
traffic flows that transmit Virtual Chassis heartbeat packets at a higher service level than
the traffic flows for traditional IP applications such as e-mail or Web browsing. During
periods of network congestion, configuring the appropriate value can ensure reliable
delivery of the heartbeat packets and decrease the likelihood of packet loss.
BEST PRACTICE: To properly prioritize the traffic flows for heartbeat packets
based on the network load, make sure you are using a value that is consistent
with the protocol standard that was implemented in your network.
Options
value—Network-specific value of the ToS, TC, or DS octet transmitted in Virtual Chassis
heartbeat packets. Depending on your network design and protocol family
implementation, the value you specify must conform to the following RFC standards:
236
•
IPv4 ToS as defined in RFC 791, INTERNET PROTOCOL - DARPA INTERNET PROGRAM
PROTOCOL SPECIFICATION
•
IPv6 traffic class (TC) as defined in RFC 2460, Internet Protocol, Version 6 (IPv6)
Specification
•
IPv4 and IPv6 Differentiated Services as defined in RFC 2474, Definition of the
Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers
•
Assured forwarding per-hop behavior (PHB) as defined in RFC 2597, Assured Forwarding
PHB Group
•
RFC 3260, New Terminology and Clarifications for Diffserv
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
Range: 0 through 255
Default: 0 (heartbeat-tos not set)
Required Privilege
Level
Related
Documentation
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
•
Virtual Chassis Heartbeat Connection Overview on page 41
locality-bias (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
Required Privilege
Level
Related
Documentation
locality-bias;
[edit virtual-chassis]
Statement introduced in Junos OS Release 14.1.
Configure unicast transit traffic for equal-cost multipath (ECMP) groups and aggregated
Ethernet bundles to egress links in the same (local) member router in an MX Series Virtual
Chassis rather than to egress links in the remote member router, provided that the local
member router has an equal or larger number of available egress links than the remote
member router.
system—To view this statement in the configuration.
system-control—To add this statement to the configuration.
•
Configuring Locality Bias for a Virtual Chassis on page 144
•
Locality Bias in a Virtual Chassis on page 141
•
Guidelines for Configuring Locality Bias in a Virtual Chassis on page 143
Copyright © 2017, Juniper Networks, Inc.
237
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
logical-interface-chassis-redundancy (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
Required Privilege
Level
Related
Documentation
logical-interface-chassis-redundancy;
[edit interfaces aenumber aggregated-ether-options]
Statement introduced in Junos OS Release 13.2.
For member routers in an MX Series Virtual Chassis, provide chassis redundancy for IP
demultiplexing (demux) and VLAN demux subscriber interfaces in aggregated Ethernet
bundles configured with targeted distribution. With chassis redundancy, the router assigns
the backup link in the aggregated Ethernet bundle to an MPC/MIC module in a member
router other than the router on which the primary link resides.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
•
Configuring Chassis Redundancy for a Virtual Chassis on page 161
logical-interface-fpc-redundancy (Aggregated Ethernet Subscriber Interfaces)
Syntax
Hierarchy Level
Release Information
Description
logical-interface-fpc-redundancy;
[edit interfaces aenumber aggregated-ether-options]
Statement introduced in Junos OS Release 11.2.
Statement introduced in Junos OS Release 13.2R2 for EX Series switches.
Provide module redundancy for demux subscribers on aggregated Ethernet bundles
configured with targeted distribution. Backup links for a subscriber are chosen on a
different EQ DPC or MPC from the primary link, based on the link with the fewest number
of subscribers among the links on different modules. If all links are on a single module
when this is configured, backup links are not provisioned.
By default, link redundancy is provided for the aggregated Ethernet bundle.
Required Privilege
Level
Related
Documentation
238
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
•
Configuring Link and Module Redundancy for Demux Subscribers in an Aggregated Ethernet
Interface
•
Configuring Module Redundancy for a Virtual Chassis on page 159
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
member (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
Options
member member-id {
role (routing-engine | line-card);
serial-number serial-number;
}
[edit virtual-chassis]
Statement introduced in Junos OS Release 11.2.
Configure an MX Series router as a member of a Virtual Chassis configuration. You can
configure a maximum of two member routers in an MX Series Virtual Chassis.
member-id—Numeric value that identifies a member router in a Virtual Chassis
configuration.
Values: 0 or 1
The remaining statements are explained separately. See CLI Explorer.
Required Privilege
Level
Related
Documentation
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
239
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
network-services
Syntax
Hierarchy Level
Release Information
Description
network-services (ethernet | enhanced-ethernet | ip | enhanced-ip | lan);
[edit chassis]
Statement introduced before Junos OS Release 8.5.
enhanced-ethernet and enhanced-ip options introduced in Junos OS Release 11.4.
limited-ifl-scaling option introduced in Junos OS Release 15.1R3 for MX Series routers.
Set the router’s network services to a specific mode of operation. On MX240, MX480,
and MX960 routers, MPC5E and MPC7E power on only if the network services mode
configured is enhanced-ip or enhanced-ethernet. All the other MPCs work with any of the
network services modes.
MX2010 and MX2020 support only enhanced-ip and enhanced-ethernet network services
modes.
Default
Options
•
MX80, MX104, MX2010, MX2020—enhanced-ip
•
MX240, MX480, MX960—ip
ethernet—Set the router’s network services to Ethernet and use standard, compiled
firewall filter format.
enhanced-ethernet—Set the router’s network services to enhanced Ethernet and use
enhanced mode capabilities. Only Trio MPCs and MS-DPCs are powered on in the
chassis.
ip—Set the router’s network services to Internet Protocol and use standard, compiled
firewall filter format.
enhanced-ip—Set the router’s network services to enhanced Internet Protocol and use
enhanced mode capabilities. Only Trio MPCs and MS-DPCs are powered on in the
chassis. Non-service DPCs do not work with enhanced network services mode options.
This feature is enabled by default on MX80, MX104, MX 2010, and 2020 3D Universal
Edge Routers.
lan—Set the router’s network services to LAN and use standard, compiled firewall filter
format. Reboot the system after setting the router’s network services to LAN.
Required Privilege
Level
Related
Documentation
240
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
•
Network Services Mode Overview
•
Firewall Filters and Enhanced Network Services Mode Overview in the Junos OS Broadband
Subscriber Management and Services Library
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
•
Configuring Junos OS to Run a Specific Network Services Mode in MX Series Routers
•
Configuring Enhanced IP Network Services for a Virtual Chassis on page 69
no-split-detection (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
no-split-detection;
[edit virtual-chassis]
Statement introduced in Junos OS Release 11.2.
As part of the preprovisioned configuration for an MX Series Virtual Chassis, disable
detection of a split in the Virtual Chassis configuration. By default, split detection in the
Virtual Chassis is enabled. To maintain the Virtual Chassis configuration in the event of
a failure of one of the two member routers, we recommend that you use the
no-split-detection statement to disable split detection in Virtual Chassis configurations
in which you think the backup router is more likely to fail than the link to the backup router.
BEST PRACTICE: We recommend that you use the no-split-detection
statement to disable split detection for a two-member MX Series Virtual
Chassis configuration if you think the backup router is more likely to fail than
the Virtual Chassis port links to the backup router. Configuring redundant
Virtual Chassis ports on different line cards in each member router reduces
the likelihood that all Virtual Chassis port interfaces to the backup router can
fail.
Required Privilege
Level
Related
Documentation
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Disabling Split Detection in a Virtual Chassis Configuration on page 98
•
Split Detection Behavior in a Virtual Chassis on page 38
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
241
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
preprovisioned (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
preprovisioned;
[edit virtual-chassis]
Statement introduced in Junos OS Release 11.2.
Enable creation of a Virtual Chassis by means of a preprovisioned configuration.
To configure a Virtual Chassis consisting of MX Series routers, you must create a
preprovisioned configuration on the master router in the Virtual Chassis by specifying the
serial number, member ID, and role for each router (member chassis) in the Virtual
Chassis. When a new member router joins the Virtual Chassis, its serial number is
compared against the values specified in the preprovisioned configuration. If the serial
number of a joining router does not match any of the configured serial numbers, the
software prevents that router from becoming a member of the Virtual Chassis.
Required Privilege
Level
Related
Documentation
242
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
role (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
Options
role (routing-engine | line-card);
[edit virtual-chassis member member-id]
Statement introduced in Junos OS Release 11.2.
As part of the preprovisioned configuration for an MX Series Virtual Chassis, assign the
role to be performed by each member router in the Virtual Chassis. The preprovisioned
configuration permanently associates the member ID and role with the member router’s
chassis serial number.
routing-engine—Enable the member router to function as the master router or backup
router of the Virtual Chassis configuration. The master router maintains the global
configuration and state information for both members of the Virtual Chassis, and
runs the chassis management processes. The backup router synchronizes with the
master router and relays chassis control information, such as line-card presence and
alarms, to the master router. If the master router is unavailable, the backup router
takes mastership of the Virtual Chassis to preserve routing information and maintain
network connectivity without disruption. You must assign the routing-engine role to
both members of the Virtual Chassis. When the Virtual Chassis is formed, the software
runs a mastership election algorithm to determine which of the two member routers
functions as the master router and which functions as the backup router of the Virtual
Chassis.
line-card—Explicitly configuring a member router with the line-card role is not supported
in the current release. However, when split detection is enabled (the default behavior
for a Virtual Chassis) and either the Virtual Chassis ports go down or the backup
router fails, the master router takes a line-card role. The line-card role effectively
removes the former master router from the Virtual Chassis configuration until
connectivity is restored.
Required Privilege
Level
Related
Documentation
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Virtual Chassis Components Overview on page 24
•
Global Roles and Local Roles in a Virtual Chassis on page 30
•
Split Detection Behavior in a Virtual Chassis on page 38
Copyright © 2017, Juniper Networks, Inc.
243
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
sampling-instance
Syntax
Hierarchy Level
sampling-instance instance-name;
[edit chassis fpc slot-number],
[edit chassis lcc number fpc slot-number] (Routing Matrix),
[edit chassis member member-number fpc slot slot-number]
Release Information
Statement introduced in Junos OS Release 9.6.
Support at the [edit chassis member member-number fpc slot slot-number] hierarchy level
introduced in Junos OS Release 14.1.
Statement introduced in Junos OS Release 14.1R3 for EX Series switches.
Description
Associate a defined sampling instance with a specific FPC, MPC, or DPC for active
sampling instances configured at the [edit forwarding-options sampling] hierarchy level.
For M120 routers with FEB, this statement must also be configured under [edit chassis
feb slot-number], in addition to the [edit forwarding-options sampling] hierarchy level.
In a two-member MX Series Virtual Chassis, the master router (member 0) uses FPC
slot numbers 0 through 11 with no offset; the backup router (member 1) uses FPC slot
numbers 12 through 23, with an offset of 12.
Required Privilege
Level
Related
Documentation
244
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
•
Associating Sampling Instances for Active Flow Monitoring with a Specific FPC, MPC, or
DPC
•
Inline Flow Monitoring for Virtual Chassis Overview on page 191
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
serial-number (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
Options
serial-number serial-number;
[edit virtual-chassis member member-id]
Statement introduced in Junos OS Release 11.2.
As part of the preprovisioned configuration for an MX Series Virtual Chassis, specify the
chassis serial number of each MX Series member router in the Virtual Chassis
configuration. If you do not correctly specify a router’s serial number in the preprovisioned
configuration, the software does not recognize that router as a member of the Virtual
Chassis.
serial-number—Alphanumeric string that represents the chassis serial number of each
member router in the Virtual Chassis configuration. The chassis serial number is
located on a label affixed to the side of the MX Series chassis. You can also obtain
the router’s chassis serial number by issuing the show chassis hardware command.
Required Privilege
Level
Related
Documentation
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
245
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
targeted-distribution (Static Interfaces over Aggregated Ethernet)
Syntax
Hierarchy Level
Release Information
Description
Required Privilege
Level
Related
Documentation
246
targeted-distribution;
[edit interfaces demux0 unit logical-unit-number],
[edit interfaces pp0 unit logical-unit-number]
Statement introduced in Junos OS Release 11.2.
Statement introduced in Junos OS Release 13.2R2 for EX Series switches.
Configure egress data for a logical interface to be sent across a single member link in an
aggregated Ethernet bundle. A backup link is provisioned with CoS scheduling resources
in the event that the primary assigned link goes down. The aggregated Ethernet interface
must be configured without link protection.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
•
CoS for PPPoE Subscriber Interfaces Overview
•
Configuring the Distribution Type for PPPoE Subscribers on Aggregated Ethernet Interfaces
•
Verifying the Distribution of PPPoE Subscribers in an Aggregated Ethernet Interface
•
Targeted Traffic Distribution on Aggregated Ethernet Interfaces in a Virtual Chassis on
page 163
•
Configuring Module Redundancy for a Virtual Chassis on page 159
•
Configuring Chassis Redundancy for a Virtual Chassis on page 161
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
traceoptions (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
Default
Options
traceoptions {
file filename <files number> <match regular-expression> <no-stamp> <replace> <size
maximum-file-size> <world-readable | no-world-readable>;
flag flag <detail> <disable> <receive> <send>;
}
[edit virtual-chassis]
Statement introduced in Junos OS Release 11.2.
Define tracing operations for the MX Series Virtual Chassis configuration.
Tracing operations are disabled.
detail—(Optional) Generate detailed trace information for a flag.
disable—(Optional) Disable a flag.
file filename—Name of the file to receive the output of the tracing operation. Enclose the
name within quotation marks. All files are placed in the directory /var/log.
files number—(Optional) Maximum number of trace files. When a trace file named
trace-file reaches its maximum size, it is renamed trace-file.0, then trace-file.1, and
so on, until the maximum number of trace files is reached. Then the oldest trace file
is overwritten. If you specify a maximum number of files, you also must specify a
maximum file size with the size option.
Range: 2 through 1000
Default: 3 files
flag flag—Tracing operation to perform. To specify more than one tracing operation,
include multiple flag statements. You can include the following flags:
•
all—All tracing operations.
•
auto-configuration—Trace Virtual Chassis ports that have been automatically
configured.
•
csn—Trace Virtual Chassis complete sequence number (CSN) packets.
•
error—Trace Virtual Chassis errored packets.
•
graceful-restart—Trace Virtual Chassis graceful restart events.
•
hello—Trace Virtual Chassis hello packets.
•
krt—Trace Virtual Chassis kernel routing table (KRT) events.
•
lsp—Trace Virtual Chassis link-state packets.
•
lsp-generation—Trace Virtual Chassis link-state packet generation.
Copyright © 2017, Juniper Networks, Inc.
247
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
•
me—Trace Virtual Chassis mastership election (ME) events.
•
normal—Trace normal events.
•
packets—Trace Virtual Chassis packets.
•
parse—Trace reading of the configuration.
•
psn—Trace partial sequence number (PSN) packets.
•
route—Trace Virtual Chassis routing information.
•
spf—Trace Virtual Chassis shortest-path-first (SPF) events.
•
state—Trace Virtual Chassis state transitions.
•
task—Trace Virtual Chassis task operations.
match regular-expression—(Optional) Refine the output to include lines that contain the
regular expression.
no-stamp—(Optional) Do not place a timestamp on any trace file.
no-world-readable—(Optional) Restrict file access to the user who created the file.
receive—(Optional) Trace received packets.
replace—(Optional) Replace a trace file instead of appending information to it.
send—(Optional) Trace transmitted packets.
size maximum-file-size—(Optional) Maximum size of each trace file. By default, the number
entered is treated as bytes. Alternatively, you can include a suffix to the number to
indicate kilobytes (KB), megabytes (MB), or gigabytes (GB). If you specify a maximum
file size, you also must specify a maximum number of trace files with the files option.
Syntax: sizek to specify KB, sizem to specify MB, or sizeg to specify GB
Range: 10240 through 1073741824
world-readable—(Optional) Enable unrestricted file access.
Required Privilege
Level
Related
Documentation
248
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Tracing Virtual Chassis Operations for MX Series 3D Universal Edge Routers on page 224
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Configuration Statements
virtual-chassis (MX Series Virtual Chassis)
Syntax
Hierarchy Level
Release Information
Description
virtual-chassis {
aliases {
serial-number serial-number;
}
graceful-restart {
disable;
}
heartbeat-address (ip-address | ipv6-address);
heartbeat-timeout seconds;
heartbeat-tos seconds;
heartbeat-tos value;
locality-bias;
member member-id {
role (routing-engine | line-card);
serial-number serial-number;
}
no-split-detection;
preprovisioned;
traceoptions {
file filename <files number> <match regular-expression> <no-stamp> <replace> <size
maximum-file-size> <world-readable | no-world-readable>;
flag flag <detail> <disable> <receive> <send>;
}
}
[edit]
Statement introduced in Junos OS Release 11.2.
Create a Virtual Chassis configuration for MX Series routers.
The remaining statements are explained separately. See CLI Explorer.
Required Privilege
Level
Related
Documentation
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
•
Configuring Preprovisioned Member Information for a Virtual Chassis on page 66
•
Configuring Locality Bias for a Virtual Chassis on page 144
Copyright © 2017, Juniper Networks, Inc.
249
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
250
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 13
Operational Commands
•
clear virtual-chassis heartbeat (MX Series Virtual Chassis)
•
request system software in-service-upgrade (MX Series 3D Universal Edge Routers
and EX9200 Switches)
•
request virtual-chassis member-id delete (MX Series Virtual Chassis)
•
request virtual-chassis member-id set
•
request virtual-chassis routing-engine master switch
•
request virtual-chassis vc-port delete (MX Series Virtual Chassis)
•
request virtual-chassis vc-port set (MX Series Virtual Chassis)
•
show chassis network-services
•
show interfaces vcp
•
show services accounting status
•
show virtual-chassis active-topology (MX Series Virtual Chassis)
•
show virtual-chassis device-topology (MX Series Virtual Chassis)
•
show virtual-chassis heartbeat (MX Series Virtual Chassis)
•
show virtual-chassis protocol adjacency (MX Series Virtual Chassis)
•
show virtual-chassis protocol database (MX Series Virtual Chassis)
•
show virtual-chassis protocol interface (MX Series Virtual Chassis)
•
show virtual-chassis protocol route (MX Series Virtual Chassis)
•
show virtual-chassis protocol statistics (MX Series Virtual Chassis)
•
show virtual-chassis status (MX Series Virtual Chassis)
•
show virtual-chassis vc-port (MX Series Virtual Chassis)
Copyright © 2017, Juniper Networks, Inc.
251
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
clear virtual-chassis heartbeat (MX Series Virtual Chassis)
Syntax
Release Information
Description
clear virtual-chassis heartbeat
<(all-members | local | member member-id)>
Command introduced in Junos OS Release 14.1.
Clear statistics counter and timestamp fields associated with a heartbeat packet
connection on both member routers in an MX Series Virtual Chassis. You can issue the
clear virtual-chassis heartbeat command from the console of either member router in
the Virtual Chassis.
NOTE: When you clear heartbeat statistics, the connection time is preserved
to retain a record of previous heartbeat connectivity.
Options
none—Clear heartbeat statistics for both member routers in an MX Series Virtual Chassis.
all-members—(Optional) Clear heartbeat statistics for both member routers in an MX
Series Virtual Chassis. This is the default behavior if no options are specified.
local—(Optional) Clear heartbeat statistics for the member router from which you are
issuing the command.
member member-id—(Optional) Clear heartbeat statistics for the specified member
router. Replace member-id with the value 0 or 1.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
252
clear
•
Verifying and Managing the Virtual Chassis Heartbeat Connection on page 190
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
clear virtual-chassis heartbeat on page 253
Table 27 on page 253 lists the output fields for the clear virtual-chassis heartbeat command.
Output fields are listed in the approximate order in which they appear.
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 27: clear virtual-chassis heartbeat Output Fields
Field Name
Field Description
membern
Member ID of the Virtual Chassis member router for which output is displayed.
heartbeat statistics
cleared
Confirmation that heartbeat statistics are cleared on the specified member
router.
Sample Output
clear virtual-chassis heartbeat
{master:member0-re0}
user@host> clear virtual-chassis heartbeat
member0:
-------------------------------------------------------------------------heartbeat statistics cleared
member1:
-------------------------------------------------------------------------heartbeat statistics cleared
Copyright © 2017, Juniper Networks, Inc.
253
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
request system software in-service-upgrade (MX Series 3D Universal Edge Routers
and EX9200 Switches)
Syntax
Release Information
Description
Options
request system software in-service-upgrade package-name
<no-copy>
<no-old-master-upgrade>
<reboot>
<unlink>
Command introduced in Junos OS Release 11.2.
Command introduced in Junos OS Release 14.1 for MX Series Virtual Chassis.
Command introduced in Junos OS Release 14.2 for EX Series switches.
Perform a unified in-service software upgrade (unified ISSU). Unified ISSU enables you
to upgrade from one Junos OS release to another with no disruption on the control plane
and with minimal disruption of traffic. Unified ISSU is supported only by dual Routing
Engine platforms. In addition, graceful Routing Engine switchover (GRES) and nonstop
active routing (NSR) must be enabled.
package-name—Location from which the software package or bundle is to be installed.
For example:
•
/var/tmp/package-name— For a software package or bundle that is being installed
from a local directory on the router.
•
protocol://hostname/pathname/package-name—For a software package or
bundle that is to be downloaded and installed from a remote location. Replace
protocol with one of the following:
•
ftp—File Transfer Protocol
•
http—Hypertext Transfer Protocol
•
scp—Secure copy (available only for Canada and U.S. version)
no-copy—(Optional) When the no-copy option is included, copies of package files are
not saved on the Packet Forwarding Engine.
The no-copy option is not available for an MX Series Virtual Chassis or an EX9200
Virtual Chassis.
no-old-master-upgrade—(Optional) When the no-old-master-upgrade option is included,
after the backup Routing Engine is rebooted with the new software package and a
switchover occurs to make it the new master Routing Engine, the former master
(new backup) Routing Engine is not upgraded to the new software. In this case, you
must manually upgrade the former master (new backup) Routing Engine. If you do
not include the no-old-master-upgrade option, the system automatically upgrades
the former master Routing Engine.
The no-old-master-upgrade option is not available for an MX Series Virtual Chassis
or an EX9200 Virtual Chassis.
254
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
reboot—(Optional) When the reboot option is included, the former master (new backup)
Routing Engine is automatically rebooted after being upgraded to the new software.
When the reboot option is not included, you must manually reboot the former master
(new backup) Routing Engine using the request system reboot command.
The reboot option is accepted but ignored for an MX Series Virtual Chassis or an
EX9200 Virtual Chassis. A unified ISSU in an MX Series Virtual Chassis or EX9200
Virtual Chassis always reboots all Routing Engines in the member routers or switches.
unlink—(Optional) When the unlink option is included, the package is removed from
/var/home whether the installation is successful or unsuccessful.
The unlink option is not available for an MX Series Virtual Chassis or an EX9200
Virtual Chassis.
Additional Information
The following conditions apply to unified ISSUs:
•
Unified ISSUs are supported on MX Series 3D Universal Edge Routers and EX9200
switches.
•
Unsupported PICs (on EX9200, PICs are known as “line cards”) are restarted during a
unified ISSU. For information about supported PICs, see the Junos OS High Availability
Library for Routing Devices. For information about supported EX9200 line cards, see
Unified ISSU System Requirements.
•
Unsupported protocols will experience packet loss during a unified ISSU. For information
about supported protocols, see the Junos OS High Availability Library for Routing Devices
or, for EX9200, see Unified ISSU System Requirements.
•
During a unified ISSU, you cannot bring any PICs online or offline.
For more information, see the Junos OS High Availability Library for Routing Devices or the
High Availability Feature Guide for EX9200 Switches.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
view
•
request system software abort
•
show chassis in-service-upgrade
request system software in-service-upgrade reboot on page 255
request system software in-service-upgrade (MX Series Virtual Chassis) on page 266
When you enter this command, you are provided feedback about the status of your
request.
Sample Output
request system software in-service-upgrade reboot
{master}
Copyright © 2017, Juniper Networks, Inc.
255
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
user@host> request system software in-service-upgrade
/var/tmp/jinstall-11.2B2.1-domestic-signed.tgz reboot
Chassis ISSU Check Done
ISSU: Validating Image
Checking compatibility with configuration
Initializing...
Using jbase-11.2B1.5
Verified manifest signed by PackageProduction_11_2_0
Verified jbase-11.2B1.5 signed by PackageProduction_11_2_0
Using /var/tmp/jinstall-11.2B2.1-domestic-signed.tgz
Verified jinstall-11.2B2.1-domestic.tgz signed by PackageProduction_11_2_0
Using jinstall-11.2B2.1-domestic.tgz
Using jbundle-11.2B2.1-domestic.tgz
Checking jbundle requirements on /
Using jbase-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jbase-11.2B2.1 signed by PackageProduction_11_2_0
Using /var/validate/chroot/tmp/jbundle/jboot-11.2B2.1.tgz
Using jcrypto-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jcrypto-11.2B2.1 signed by PackageProduction_11_2_0
Using jdocs-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jdocs-11.2B2.1 signed by PackageProduction_11_2_0
Using jkernel-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jkernel-11.2B2.1 signed by PackageProduction_11_2_0
Using jpfe-11.2B2.1.tgz
Using jroute-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jroute-11.2B2.1 signed by PackageProduction_11_2_0
Using jruntime-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jruntime-11.2B2.1 signed by PackageProduction_11_2_0
Using jservices-11.2B2.1.tgz
Auto-deleting old jservices-voice ...
Removing /opt/sdk/service-packages/jservices-voice ...
Removing jservices-voice-bsg-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-voice ...
Verified jservices-voice-bsg-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /var/sw/pkg ...
Creating /opt/sdk/service-packages/jservices-voice ...
Storing jservices-voice-bsg-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-voice/jservices-voice-bsg ->
/var/sw/pkg/jservices-voice-bsg-11.2B2.1.tgz...
Auto-deleting old jservices-bgf ...
Removing /opt/sdk/service-packages/jservices-bgf ...
Removing jservices-bgf-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-bgf ...
Verified jservices-bgf-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-bgf ...
Storing jservices-bgf-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-bgf/jservices-bgf-pic ->
/var/sw/pkg/jservices-bgf-pic-11.2B2.1.tgz...
Auto-deleting old jservices-aacl ...
Removing /opt/sdk/service-packages/jservices-aacl ...
Removing jservices-aacl-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-aacl ...
256
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Verified jservices-aacl-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-aacl ...
Storing jservices-aacl-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-aacl/jservices-aacl-pic ->
/var/sw/pkg/jservices-aacl-pic-11.2B2.1.tgz...
Auto-deleting old jservices-llpdf ...
Removing /opt/sdk/service-packages/jservices-llpdf ...
Removing jservices-llpdf-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-llpdf ...
Verified jservices-llpdf-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-llpdf ...
Storing jservices-llpdf-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-llpdf/jservices-llpdf-pic ->
/var/sw/pkg/jservices-llpdf-pic-11.2B2.1.tgz...
Auto-deleting old jservices-ptsp ...
Removing /opt/sdk/service-packages/jservices-ptsp ...
Removing jservices-ptsp-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-ptsp ...
Verified jservices-ptsp-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-ptsp ...
Storing jservices-ptsp-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-ptsp/jservices-ptsp-pic ->
/var/sw/pkg/jservices-ptsp-pic-11.2B2.1.tgz...
Auto-deleting old jservices-sfw ...
Removing /opt/sdk/service-packages/jservices-sfw ...
Removing jservices-sfw-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-sfw ...
Verified jservices-sfw-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-sfw ...
Storing jservices-sfw-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-sfw/jservices-sfw-pic ->
/var/sw/pkg/jservices-sfw-pic-11.2B2.1.tgz...
Auto-deleting old jservices-nat ...
Removing /opt/sdk/service-packages/jservices-nat ...
Removing jservices-nat-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-nat ...
Verified jservices-nat-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-nat ...
Storing jservices-nat-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-nat/jservices-nat-pic ->
/var/sw/pkg/jservices-nat-pic-11.2B2.1.tgz...
Auto-deleting old jservices-alg ...
Removing /opt/sdk/service-packages/jservices-alg ...
Removing jservices-alg-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-alg ...
Verified jservices-alg-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-alg ...
Storing jservices-alg-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-alg/jservices-alg-pic ->
/var/sw/pkg/jservices-alg-pic-11.2B2.1.tgz...
Auto-deleting old jservices-cpcd ...
Removing /opt/sdk/service-packages/jservices-cpcd ...
Removing jservices-cpcd-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-cpcd ...
Verified jservices-cpcd-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Copyright © 2017, Juniper Networks, Inc.
257
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Creating /opt/sdk/service-packages/jservices-cpcd ...
Storing jservices-cpcd-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-cpcd/jservices-cpcd-pic ->
/var/sw/pkg/jservices-cpcd-pic-11.2B2.1.tgz...
Auto-deleting old jservices-rpm ...
Removing /opt/sdk/service-packages/jservices-rpm ...
Removing jservices-rpm-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-rpm ...
Verified jservices-rpm-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-rpm ...
Storing jservices-rpm-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-rpm/jservices-rpm-pic ->
/var/sw/pkg/jservices-rpm-pic-11.2B2.1.tgz...
Auto-deleting old jservices-hcm ...
Removing /opt/sdk/service-packages/jservices-hcm ...
Removing jservices-hcm-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-hcm ...
Verified jservices-hcm-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-hcm ...
Storing jservices-hcm-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-hcm/jservices-hcm-pic ->
/var/sw/pkg/jservices-hcm-pic-11.2B2.1.tgz...
Auto-deleting old jservices-appid ...
Removing /opt/sdk/service-packages/jservices-appid ...
Removing jservices-appid-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-appid ...
Verified jservices-appid-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-appid ...
Storing jservices-appid-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-appid/jservices-appid-pic ->
/var/sw/pkg/jservices-appid-pic-11.2B2.1.tgz...
Auto-deleting old jservices-idp ...
Removing /opt/sdk/service-packages/jservices-idp ...
Removing jservices-idp-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-idp ...
Verified jservices-idp-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-idp ...
Storing jservices-idp-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-idp/jservices-idp-pic ->
/var/sw/pkg/jservices-idp-pic-11.2B2.1.tgz...
Using jservices-crypto-11.2B2.1.tgz
Auto-deleting old jservices-crypto-base ...
Removing /opt/sdk/service-packages/jservices-crypto-base ...
Removing jservices-crypto-base-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-crypto-base ...
Verified jservices-crypto-base-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-crypto-base ...
Storing jservices-crypto-base-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-crypto-base/jservices-crypto-base-pic
-> /var/sw/pkg/jservices-crypto-base-pic-11.2B2.1.tgz...
Auto-deleting old jservices-ssl ...
Removing /opt/sdk/service-packages/jservices-ssl ...
Removing jservices-ssl-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-ssl ...
Verified jservices-ssl-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
258
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Creating /opt/sdk/service-packages/jservices-ssl ...
Storing jservices-ssl-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-ssl/jservices-ssl-pic ->
/var/sw/pkg/jservices-ssl-pic-11.2B2.1.tgz...
Hardware Database regeneration succeeded
Validating against /config/juniper.conf.gz
mgd: commit complete
Validation succeeded
ISSU: Preparing Backup RE
Pushing bundle to re1
NOTICE: Validating configuration against jinstall-11.2B2.1-domestic-signed.tgz.
NOTICE: Use the 'no-validate' option to skip this if desired.
Checking compatibility with configuration
Initializing...
Using jbase-11.2B1.5
Verified manifest signed by PackageProduction_11_2_0
Verified jbase-11.2B1.5 signed by PackageProduction_11_2_0
Using /var/tmp/jinstall-11.2B2.1-domestic-signed.tgz
Verified jinstall-11.2B2.1-domestic.tgz signed by PackageProduction_11_2_0
Using jinstall-11.2B2.1-domestic.tgz
Using jbundle-11.2B2.1-domestic.tgz
Checking jbundle requirements on /
Using jbase-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jbase-11.2B2.1 signed by PackageProduction_11_2_0
Using /var/validate/chroot/tmp/jbundle/jboot-11.2B2.1.tgz
Using jcrypto-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jcrypto-11.2B2.1 signed by PackageProduction_11_2_0
Using jdocs-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jdocs-11.2B2.1 signed by PackageProduction_11_2_0
Using jkernel-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jkernel-11.2B2.1 signed by PackageProduction_11_2_0
Using jpfe-11.2B2.1.tgz
Using jroute-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jroute-11.2B2.1 signed by PackageProduction_11_2_0
Using jruntime-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jruntime-11.2B2.1 signed by PackageProduction_11_2_0
Using jservices-11.2B2.1.tgz
Auto-deleting old jservices-voice ...
Removing /opt/sdk/service-packages/jservices-voice ...
Removing jservices-voice-bsg-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-voice ...
Verified jservices-voice-bsg-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /var/sw/pkg ...
Creating /opt/sdk/service-packages/jservices-voice ...
Storing jservices-voice-bsg-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-voice/jservices-voice-bsg ->
/var/sw/pkg/jservices-voice-bsg-11.2B2.1.tgz...
Auto-deleting old jservices-bgf ...
Removing /opt/sdk/service-packages/jservices-bgf ...
Removing jservices-bgf-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-bgf ...
Verified jservices-bgf-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-bgf ...
Copyright © 2017, Juniper Networks, Inc.
259
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Storing jservices-bgf-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-bgf/jservices-bgf-pic ->
/var/sw/pkg/jservices-bgf-pic-11.2B2.1.tgz...
Auto-deleting old jservices-aacl ...
Removing /opt/sdk/service-packages/jservices-aacl ...
Removing jservices-aacl-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-aacl ...
Verified jservices-aacl-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-aacl ...
Storing jservices-aacl-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-aacl/jservices-aacl-pic ->
/var/sw/pkg/jservices-aacl-pic-11.2B2.1.tgz...
Auto-deleting old jservices-llpdf ...
Removing /opt/sdk/service-packages/jservices-llpdf ...
Removing jservices-llpdf-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-llpdf ...
Verified jservices-llpdf-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-llpdf ...
Storing jservices-llpdf-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-llpdf/jservices-llpdf-pic ->
/var/sw/pkg/jservices-llpdf-pic-11.2B2.1.tgz...
Auto-deleting old jservices-ptsp ...
Removing /opt/sdk/service-packages/jservices-ptsp ...
Removing jservices-ptsp-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-ptsp ...
Verified jservices-ptsp-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-ptsp ...
Storing jservices-ptsp-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-ptsp/jservices-ptsp-pic ->
/var/sw/pkg/jservices-ptsp-pic-11.2B2.1.tgz...
Auto-deleting old jservices-sfw ...
Removing /opt/sdk/service-packages/jservices-sfw ...
Removing jservices-sfw-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-sfw ...
Verified jservices-sfw-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-sfw ...
Storing jservices-sfw-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-sfw/jservices-sfw-pic ->
/var/sw/pkg/jservices-sfw-pic-11.2B2.1.tgz...
Auto-deleting old jservices-nat ...
Removing /opt/sdk/service-packages/jservices-nat ...
Removing jservices-nat-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-nat ...
Verified jservices-nat-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-nat ...
Storing jservices-nat-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-nat/jservices-nat-pic ->
/var/sw/pkg/jservices-nat-pic-11.2B2.1.tgz...
Auto-deleting old jservices-alg ...
Removing /opt/sdk/service-packages/jservices-alg ...
Removing jservices-alg-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-alg ...
Verified jservices-alg-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-alg ...
Storing jservices-alg-pic-11.2B2.1.tgz in /var/sw/pkg ...
260
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Link: /opt/sdk/service-packages/jservices-alg/jservices-alg-pic ->
/var/sw/pkg/jservices-alg-pic-11.2B2.1.tgz...
Auto-deleting old jservices-cpcd ...
Removing /opt/sdk/service-packages/jservices-cpcd ...
Removing jservices-cpcd-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-cpcd ...
Verified jservices-cpcd-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-cpcd ...
Storing jservices-cpcd-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-cpcd/jservices-cpcd-pic ->
/var/sw/pkg/jservices-cpcd-pic-11.2B2.1.tgz...
Auto-deleting old jservices-rpm ...
Removing /opt/sdk/service-packages/jservices-rpm ...
Removing jservices-rpm-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-rpm ...
Verified jservices-rpm-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-rpm ...
Storing jservices-rpm-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-rpm/jservices-rpm-pic ->
/var/sw/pkg/jservices-rpm-pic-11.2B2.1.tgz...
Auto-deleting old jservices-hcm ...
Removing /opt/sdk/service-packages/jservices-hcm ...
Removing jservices-hcm-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-hcm ...
Verified jservices-hcm-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-hcm ...
Storing jservices-hcm-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-hcm/jservices-hcm-pic ->
/var/sw/pkg/jservices-hcm-pic-11.2B2.1.tgz...
Auto-deleting old jservices-appid ...
Removing /opt/sdk/service-packages/jservices-appid ...
Removing jservices-appid-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-appid ...
Verified jservices-appid-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-appid ...
Storing jservices-appid-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-appid/jservices-appid-pic ->
/var/sw/pkg/jservices-appid-pic-11.2B2.1.tgz...
Auto-deleting old jservices-idp ...
Removing /opt/sdk/service-packages/jservices-idp ...
Removing jservices-idp-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-idp ...
Verified jservices-idp-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-idp ...
Storing jservices-idp-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-idp/jservices-idp-pic ->
/var/sw/pkg/jservices-idp-pic-11.2B2.1.tgz...
Using jservices-crypto-11.2B2.1.tgz
Auto-deleting old jservices-crypto-base ...
Removing /opt/sdk/service-packages/jservices-crypto-base ...
Removing jservices-crypto-base-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-crypto-base ...
Verified jservices-crypto-base-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-crypto-base ...
Storing jservices-crypto-base-pic-11.2B2.1.tgz in /var/sw/pkg ...
Copyright © 2017, Juniper Networks, Inc.
261
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Link: /opt/sdk/service-packages/jservices-crypto-base/jservices-crypto-base-pic
-> /var/sw/pkg/jservices-crypto-base-pic-11.2B2.1.tgz...
Auto-deleting old jservices-ssl ...
Removing /opt/sdk/service-packages/jservices-ssl ...
Removing jservices-ssl-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-ssl ...
Verified jservices-ssl-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-ssl ...
Storing jservices-ssl-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-ssl/jservices-ssl-pic ->
/var/sw/pkg/jservices-ssl-pic-11.2B2.1.tgz...
Hardware Database regeneration succeeded
Validating against /config/juniper.conf.gz
mgd: commit complete
Validation succeeded
Installing package '/var/tmp/jinstall-11.2B2.1-domestic-signed.tgz' ...
Verified jinstall-11.2B2.1-domestic.tgz signed by PackageProduction_11_2_0
Adding jinstall...
Verified manifest signed by PackageProduction_11_2_0
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
This package will load JUNOS 11.2B2.1 software.
It will save JUNOS configuration files, and SSH keys
(if configured), but erase all other files and information
stored on this machine. It will attempt to preserve dumps
and log files, but this can not be guaranteed. This is the
pre-installation stage and all the software is loaded when
you reboot the system.
Saving the config files ...
NOTICE: uncommitted changes have been saved in
/var/db/config/juniper.conf.pre-install
Installing the bootstrap installer ...
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
'request system reboot' command when software installation is
complete. To abort the installation, do not reboot your system,
instead use the 'request system software delete jinstall'
command as soon as this operation completes.
Saving package file in /var/sw/pkg/jinstall-11.2B2.1-domestic-signed.tgz ...
Saving state for rollback ...
Backup upgrade done
Rebooting Backup RE
Rebooting re1
ISSU: Backup RE Prepare Done
Waiting for Backup RE reboot
GRES operational
Initiating Chassis In-Service-Upgrade
Chassis ISSU Started
ISSU: Preparing Daemons
ISSU: Daemons Ready for ISSU
ISSU: Starting Upgrade for FRUs
ISSU: Preparing for Switchover
ISSU: Ready for Switchover
Checking In-Service-Upgrade status
Item
Status
FPC 1
Online (ISSU)
FPC 4
Online (ISSU)
FPC 8
Online (ISSU)
262
Reason
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
FPC 10
Online (ISSU)
Resolving mastership...
Complete. The other routing engine becomes the master.
ISSU: RE switchover Done
ISSU: Upgrading Old Master RE
NOTICE: Validating configuration against jinstall-11.2B2.1-domestic-signed.tgz.
NOTICE: Use the 'no-validate' option to skip this if desired.
Checking compatibility with configuration
Initializing...
Using jbase-11.2B1.5
Verified manifest signed by PackageProduction_11_2_0
Verified jbase-11.2B1.5 signed by PackageProduction_11_2_0
Using /var/tmp/jinstall-11.2B2.1-domestic-signed.tgz
Verified jinstall-11.2B2.1-domestic.tgz signed by PackageProduction_11_2_0
Using jinstall-11.2B2.1-domestic.tgz
Using jbundle-11.2B2.1-domestic.tgz
Checking jbundle requirements on /
Using jbase-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jbase-11.2B2.1 signed by PackageProduction_11_2_0
Using /var/validate/chroot/tmp/jbundle/jboot-11.2B2.1.tgz
Using jcrypto-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jcrypto-11.2B2.1 signed by PackageProduction_11_2_0
Using jdocs-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jdocs-11.2B2.1 signed by PackageProduction_11_2_0
Using jkernel-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jkernel-11.2B2.1 signed by PackageProduction_11_2_0
Using jpfe-11.2B2.1.tgz
Using jroute-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jroute-11.2B2.1 signed by PackageProduction_11_2_0
Using jruntime-11.2B2.1.tgz
Verified manifest signed by PackageProduction_11_2_0
Verified jruntime-11.2B2.1 signed by PackageProduction_11_2_0
Using jservices-11.2B2.1.tgz
Auto-deleting old jservices-voice ...
Removing /opt/sdk/service-packages/jservices-voice ...
Removing jservices-voice-bsg-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-voice ...
Verified jservices-voice-bsg-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /var/sw/pkg ...
Creating /opt/sdk/service-packages/jservices-voice ...
Storing jservices-voice-bsg-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-voice/jservices-voice-bsg ->
/var/sw/pkg/jservices-voice-bsg-11.2B2.1.tgz...
Auto-deleting old jservices-bgf ...
Removing /opt/sdk/service-packages/jservices-bgf ...
Removing jservices-bgf-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-bgf ...
Verified jservices-bgf-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-bgf ...
Storing jservices-bgf-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-bgf/jservices-bgf-pic ->
/var/sw/pkg/jservices-bgf-pic-11.2B2.1.tgz...
Auto-deleting old jservices-aacl ...
Removing /opt/sdk/service-packages/jservices-aacl ...
Copyright © 2017, Juniper Networks, Inc.
263
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Removing jservices-aacl-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-aacl ...
Verified jservices-aacl-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-aacl ...
Storing jservices-aacl-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-aacl/jservices-aacl-pic ->
/var/sw/pkg/jservices-aacl-pic-11.2B2.1.tgz...
Auto-deleting old jservices-llpdf ...
Removing /opt/sdk/service-packages/jservices-llpdf ...
Removing jservices-llpdf-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-llpdf ...
Verified jservices-llpdf-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-llpdf ...
Storing jservices-llpdf-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-llpdf/jservices-llpdf-pic ->
/var/sw/pkg/jservices-llpdf-pic-11.2B2.1.tgz...
Auto-deleting old jservices-ptsp ...
Removing /opt/sdk/service-packages/jservices-ptsp ...
Removing jservices-ptsp-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-ptsp ...
Verified jservices-ptsp-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-ptsp ...
Storing jservices-ptsp-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-ptsp/jservices-ptsp-pic ->
/var/sw/pkg/jservices-ptsp-pic-11.2B2.1.tgz...
Auto-deleting old jservices-sfw ...
Removing /opt/sdk/service-packages/jservices-sfw ...
Removing jservices-sfw-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-sfw ...
Verified jservices-sfw-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-sfw ...
Storing jservices-sfw-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-sfw/jservices-sfw-pic ->
/var/sw/pkg/jservices-sfw-pic-11.2B2.1.tgz...
Auto-deleting old jservices-nat ...
Removing /opt/sdk/service-packages/jservices-nat ...
Removing jservices-nat-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-nat ...
Verified jservices-nat-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-nat ...
Storing jservices-nat-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-nat/jservices-nat-pic ->
/var/sw/pkg/jservices-nat-pic-11.2B2.1.tgz...
Auto-deleting old jservices-alg ...
Removing /opt/sdk/service-packages/jservices-alg ...
Removing jservices-alg-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-alg ...
Verified jservices-alg-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-alg ...
Storing jservices-alg-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-alg/jservices-alg-pic ->
/var/sw/pkg/jservices-alg-pic-11.2B2.1.tgz...
Auto-deleting old jservices-cpcd ...
Removing /opt/sdk/service-packages/jservices-cpcd ...
Removing jservices-cpcd-pic-11.2B1.5.tgz from /var/sw/pkg ...
264
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Notifying mspd ...
Installing new jservices-cpcd ...
Verified jservices-cpcd-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-cpcd ...
Storing jservices-cpcd-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-cpcd/jservices-cpcd-pic ->
/var/sw/pkg/jservices-cpcd-pic-11.2B2.1.tgz...
Auto-deleting old jservices-rpm ...
Removing /opt/sdk/service-packages/jservices-rpm ...
Removing jservices-rpm-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-rpm ...
Verified jservices-rpm-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-rpm ...
Storing jservices-rpm-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-rpm/jservices-rpm-pic ->
/var/sw/pkg/jservices-rpm-pic-11.2B2.1.tgz...
Auto-deleting old jservices-hcm ...
Removing /opt/sdk/service-packages/jservices-hcm ...
Removing jservices-hcm-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-hcm ...
Verified jservices-hcm-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-hcm ...
Storing jservices-hcm-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-hcm/jservices-hcm-pic ->
/var/sw/pkg/jservices-hcm-pic-11.2B2.1.tgz...
Auto-deleting old jservices-appid ...
Removing /opt/sdk/service-packages/jservices-appid ...
Removing jservices-appid-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-appid ...
Verified jservices-appid-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-appid ...
Storing jservices-appid-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-appid/jservices-appid-pic ->
/var/sw/pkg/jservices-appid-pic-11.2B2.1.tgz...
Auto-deleting old jservices-idp ...
Removing /opt/sdk/service-packages/jservices-idp ...
Removing jservices-idp-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-idp ...
Verified jservices-idp-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-idp ...
Storing jservices-idp-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-idp/jservices-idp-pic ->
/var/sw/pkg/jservices-idp-pic-11.2B2.1.tgz...
Using jservices-crypto-11.2B2.1.tgz
Auto-deleting old jservices-crypto-base ...
Removing /opt/sdk/service-packages/jservices-crypto-base ...
Removing jservices-crypto-base-pic-11.2B1.5.tgz from /var/sw/pkg ...
Notifying mspd ...
Installing new jservices-crypto-base ...
Verified jservices-crypto-base-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-crypto-base ...
Storing jservices-crypto-base-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-crypto-base/jservices-crypto-base-pic
-> /var/sw/pkg/jservices-crypto-base-pic-11.2B2.1.tgz...
Auto-deleting old jservices-ssl ...
Removing /opt/sdk/service-packages/jservices-ssl ...
Removing jservices-ssl-pic-11.2B1.5.tgz from /var/sw/pkg ...
Copyright © 2017, Juniper Networks, Inc.
265
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Notifying mspd ...
Installing new jservices-ssl ...
Verified jservices-ssl-pic-11.2B2.1.tgz signed by PackageProduction_11_2_0
Creating /opt/sdk/service-packages/jservices-ssl ...
Storing jservices-ssl-pic-11.2B2.1.tgz in /var/sw/pkg ...
Link: /opt/sdk/service-packages/jservices-ssl/jservices-ssl-pic ->
/var/sw/pkg/jservices-ssl-pic-11.2B2.1.tgz...
Hardware Database regeneration succeeded
Validating against /config/juniper.conf.gz
mgd: commit complete
Validation succeeded
Installing package '/var/tmp/jinstall-11.2B2.1-domestic-signed.tgz' ...
Verified jinstall-11.2B2.1-domestic.tgz signed by PackageProduction_11_2_0
Adding jinstall...
Verified manifest signed by PackageProduction_11_2_0
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
This package will load JUNOS 11.2B2.1 software.
It will save JUNOS configuration files, and SSH keys
(if configured), but erase all other files and information
stored on this machine. It will attempt to preserve dumps
and log files, but this can not be guaranteed. This is the
pre-installation stage and all the software is loaded when
you reboot the system.
Saving the config files ...
NOTICE: uncommitted changes have been saved in
/var/db/config/juniper.conf.pre-install
Installing the bootstrap installer ...
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
'request system reboot' command when software installation is
complete. To abort the installation, do not reboot your system,
instead use the 'request system software delete jinstall'
command as soon as this operation completes.
Saving package file in /var/sw/pkg/jinstall-11.2B2.1-domestic-signed.tgz ...
Saving state for rollback ...
ISSU: Old Master Upgrade Done
ISSU: IDLE
Shutdown NOW!
Reboot consistency check bypassed - jinstall 11.2B2.1 will complete installation
upon reboot
[pid 66780]
*** FINAL System shutdown message from user@host> ***
System going down IMMEDIATELY
request system software in-service-upgrade (MX Series Virtual Chassis)
{master:member0-re0}
user@host> request system software in-service-upgrade
jinstall-14.1-20140114.2-domestic-signed.tgz
[Jan 30 10:45:32]:ISSU: IDLE
Beginning in-service-upgrade at Jan 30, 2014; 10:45:34
[Jan 30 10:45:34]:ISSU: Validating Image
Validating VC readiness...
Validating required configuration...
Validating release compatibility...
Validation successful
266
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Initiating chassis in-service-upgrade
[Jan 30 10:46:56]:ISSU: Preparing LCC Backup REs
Copying new release to all RE's
Pushing bundle to member0-re0
Pushing bundle to member1-re0
Pushing bundle to member1-re1
[Jan 30 10:51:11]:ISSU: Preparing Backup RE
Arming new release on all RE's
member0-re0:
-------------------------------------------------------------------------Installing package
'/var/tmp/jinstall-14.1-20140114_ib_14_1_psd.1-domestic-signed.tgz' ...
Verified jinstall-14.1-20140114_ib_14_1_psd.1-domestic.tgz signed by
PackageDevelopmentEc_2014
Adding jinstall...
WARNING:
WARNING:
The software that is being installed has limited support.
Run 'file show /etc/notices/unsupported.txt' for details.
veriexec: accepting signer: PackageDevelopmentEc_2014
Verified manifest signed by PackageDevelopmentEc_2014
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
This package will load JUNOS 14.1-20140114_ib_14_1_psd.1 software.
It will save JUNOS configuration files, and SSH keys
(if configured), but erase all other files and information
stored on this machine. It will attempt to preserve dumps
and log files, but this can not be guaranteed. This is the
pre-installation stage and all the software is loaded when
you reboot the system.
Saving the config files ...
NOTICE: uncommitted changes have been saved in
/var/db/config/juniper.conf.pre-install
Installing the bootstrap installer ...
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
'request system reboot' command when software installation is
complete. To abort the installation, do not reboot your system,
instead use the 'request system software delete jinstall'
command as soon as this operation completes.
Saving package file in
/var/sw/pkg/jinstall-14.1-20140114_ib_14_1_psd.1-domestic-signed.tgz ...
Saving state for rollback ...
member1-re0:
-------------------------------------------------------------------------Installing package
'/var/tmp/jinstall-14.1-20140114_ib_14_1_psd.1-domestic-signed.tgz' ...
Verified jinstall-14.1-20140114_ib_14_1_psd.1-domestic.tgz signed by
PackageDevelopmentEc_2014
Adding jinstall...
WARNING:
WARNING:
The software that is being installed has limited support.
Run 'file show /etc/notices/unsupported.txt' for details.
veriexec: accepting signer: PackageDevelopmentEc_2014
Verified manifest signed by PackageDevelopmentEc_2014
WARNING:
WARNING:
Copyright © 2017, Juniper Networks, Inc.
This package will load JUNOS 14.1-20140114_ib_14_1_psd.1 software.
It will save JUNOS configuration files, and SSH keys
267
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
(if configured), but erase all other files and information
stored on this machine. It will attempt to preserve dumps
and log files, but this can not be guaranteed. This is the
pre-installation stage and all the software is loaded when
you reboot the system.
Saving the config files ...
NOTICE: uncommitted changes have been saved in
/var/db/config/juniper.conf.pre-install
Installing the bootstrap installer ...
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
'request system reboot' command when software installation is
complete. To abort the installation, do not reboot your system,
instead use the 'request system software delete jinstall'
command as soon as this operation completes.
Saving package file in
/var/sw/pkg/jinstall-14.1-20140114_ib_14_1_psd.1-domestic-signed.tgz ...
Saving state for rollback ...
member1-re1:
-------------------------------------------------------------------------Installing package
'/var/tmp/jinstall-14.1-20140114_ib_14_1_psd.1-domestic-signed.tgz' ...
Verified jinstall-14.1-20140114_ib_14_1_psd.1-domestic.tgz signed by
PackageDevelopmentEc_2014
Adding jinstall...
WARNING:
WARNING:
The software that is being installed has limited support.
Run 'file show /etc/notices/unsupported.txt' for details.
veriexec: accepting signer: PackageDevelopmentEc_2014
Verified manifest signed by PackageDevelopmentEc_2014
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
This package will load JUNOS 14.1-20140114_ib_14_1_psd.1 software.
It will save JUNOS configuration files, and SSH keys
(if configured), but erase all other files and information
stored on this machine. It will attempt to preserve dumps
and log files, but this can not be guaranteed. This is the
pre-installation stage and all the software is loaded when
you reboot the system.
Saving the config files ...
NOTICE: uncommitted changes have been saved in
/var/db/config/juniper.conf.pre-install
Installing the bootstrap installer ...
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
'request system reboot' command when software installation is
complete. To abort the installation, do not reboot your system,
instead use the 'request system software delete jinstall'
command as soon as this operation completes.
Saving package file in
/var/sw/pkg/jinstall-14.1-20140114_ib_14_1_psd.1-domestic-signed.tgz ...
Saving state for rollback ...
Installing package
'/var/tmp/jinstall-14.1-20140114_ib_14_1_psd.1-domestic-signed.tgz' ...
Verified jinstall-14.1-20140114_ib_14_1_psd.1-domestic.tgz signed by
PackageDevelopmentEc_2014
268
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Adding jinstall...
WARNING:
WARNING:
The software that is being installed has limited support.
Run 'file show /etc/notices/unsupported.txt' for details.
veriexec: accepting signer: PackageDevelopmentEc_2014
Verified manifest signed by PackageDevelopmentEc_2014
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
This package will load JUNOS 14.1-20140114_ib_14_1_psd.1 software.
It will save JUNOS configuration files, and SSH keys
(if configured), but erase all other files and information
stored on this machine. It will attempt to preserve dumps
and log files, but this can not be guaranteed. This is the
pre-installation stage and all the software is loaded when
you reboot the system.
Saving the config files ...
NOTICE: uncommitted changes have been saved in
/var/db/config/juniper.conf.pre-install
Installing the bootstrap installer ...
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
'request system reboot' command when software installation is
complete. To abort the installation, do not reboot your system,
instead use the 'request system software delete jinstall'
command as soon as this operation completes.
Saving package file in
/var/sw/pkg/jinstall-14.1-20140114_ib_14_1_psd.1-domestic-signed.tgz ...
Saving state for rollback ...
[Jan 30 11:03:12]:ISSU: Backup RE Prepare Done
Rebooting standby RE's
Sending Reboot Command to member0-re0
Shutdown NOW!
Reboot consistency check bypassed - jinstall 14.1-20140114_ib_14_1_psd.1 will
complete installation upon reboot
[pid 2757]
Sending Reboot Command to member1-re1
Shutdown NOW!
Reboot consistency check bypassed - jinstall 14.1-20140114_ib_14_1_psd.1 will
complete installation upon reboot
[pid 2670]
Waiting for standby RE's to boot
[Jan 30 11:18:26]:ISSU: LCC Backup REs Prepare Done
Waiting for standby RE's to have the correct ISSU state
Waiting for protocol backup to be ready to switch mastership
Switching mastership on the protocol backup chassis to slot 1
Waiting for protocol backup chassis master switch to complete
Globally updating ISSU state
Waiting for protocol backup chassis to become GRES ready
[Jan 30 11:19:18]:ISSU: VC Protocol Backup has Switched
Passing ISSU control to chassisd
Chassis ISSU Started
[Jan 30 11:21:01]:ISSU: Preparing Daemons
[Jan 30 11:22:02]:ISSU: Daemons Ready for ISSU
[Jan 30 11:22:06]:ISSU: Starting Upgrade for FRUs
[Jan 30 11:25:42]:ISSU: Preparing for Switchover
[Jan 30 11:26:06]:ISSU: Ready for Switchover
[Jan 30 11:26:20]:ISSU: All VC Members Ready for Switchover
Waiting for master chassis to be switch ready
Switching mastership locally
Copyright © 2017, Juniper Networks, Inc.
269
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Resolving mastership...
Complete. The other routing engine becomes the master.
Waiting for virtual chassis roles to switch
Globally updating ISSU state to IDLE
[Jan 30 11:26:33]:ISSU: IDLE
Rebooting protocol backup standby RE.
Sending Reboot Command to member1-re0
member1-re0:
-------------------------------------------------------------------------Shutdown NOW!
Reboot consistency check bypassed - jinstall 14.1-20140114_ib_14_1_psd.1 will
complete installation upon reboot
[pid 10462]
Rebooting locally to complete the in service upgrade.
Shutdown NOW!
Reboot consistency check bypassed - jinstall 14.1-20140114_ib_14_1_psd.1 will
complete installation upon reboot
[pid 13458]
{local:member0-re1}
user@host>
*** FINAL System shutdown message from user@host ***
System going down IMMEDIATELY
Connection closed by foreign host.
270
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
request virtual-chassis member-id delete (MX Series Virtual Chassis)
Syntax
Release Information
Description
request virtual-chassis member-id delete
Command introduced in Junos OS Release 11.2.
Command introduced in Junos OS Release 13.2R2 for EX Series switches.
Remove (delete) the member ID from a router or switch that you want to remove from
a Virtual Chassis configuration.
NOTE: Issuing the command to remove the member ID causes the device to
reboot, and requires you to confirm that you want to proceed with this
operation. If you do not confirm the operation, the software cancels the
command.
Required Privilege
Level
Related
Documentation
List of Sample Output
system-control
•
Deleting Member IDs in a Virtual Chassis Configuration on page 97
•
Example: Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers on page 111
request virtual-chassis member-id delete on page 271
Sample Output
request virtual-chassis member-id delete
user@host> request virtual-chassis member-id delete
This command will disable virtual-chassis mode and reboot the system.
Continue? [yes,no] (no)
Copyright © 2017, Juniper Networks, Inc.
271
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
request virtual-chassis member-id set
Syntax
request virtual-chassis member-id set member member-id
Syntax (MX960,
MX2010, and MX2020
Routers)
request virtual-chassis member-id set member member-id
<slots-per-chassis slot-count>
Release Information
Description
Command introduced in Junos OS Release 11.2.
Command introduced in Junos OS Release 13.2R2 for EX Series switches.
slots-per-chassis option added in Junos OS Release 15.1 for MX960 routers, MX2010
routers, and MX2020 routers.
Assign (set) a member ID and, optionally, a slot count to a router or switch that you want
to add as a member of a Virtual Chassis configuration.
NOTE: Issuing the request virtual-chassis member-id set command causes
the device to reboot, and requires you to confirm that you want to proceed
with this operation. If you do not confirm the operation, the software cancels
the command. After the reboot all MPCs remain powered off until the Virtual
Chassis port connection is configured.
Options
member member-id—Assign the numeric value that identifies a member router or switch
in a Virtual Chassis configuration. When you assign a member ID to a router or switch,
assign the same member ID defined for this device in the preprovisioned configuration.
Replace member-id with the value 0 or 1.
slots-per-chassis slot-count—(MX960, MX2010, and MX2020 routers) (Optional) Identify
the number of chassis slots in the Virtual Chassis member router. To ensure that a
Virtual Chassis consisting of an MX2020 member router and either an MX960 or
MX2010 member router forms properly, you must explicitly set the slot-count value
for the MX960 router or MX2010 router to 20 to match the slot count of the MX2020
router.
Values:
The valid values for slot-count are as follows:
•
MX960 router: 12 or 20
•
MX2010 router: 12 or 20
•
MX2020 router: 20
Default:
The default values for slot-count are as follows:
•
272
MX960 router: 12
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Required Privilege
Level
Related
Documentation
List of Sample Output
•
MX2010 router: 12
•
MX2020 router: 20
system-control
•
Configuring Member IDs for a Virtual Chassis on page 72
•
Configuring an EX9200 Virtual Chassis
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
request virtual-chassis member-id set (Assigning a Member ID) on page 273
request virtual-chassis member-id set (Assigning a Member ID and Slot
Count) on page 273
Sample Output
request virtual-chassis member-id set (Assigning a Member ID)
user@host> request virtual-chassis member-id set member 0
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] (no)
request virtual-chassis member-id set (Assigning a Member ID and Slot Count)
user@host> request virtual-chassis member-id set member 1 slots-per-chassis 20
This command will enable virtual-chassis mode and reboot the system.
Continue? [yes,no] (no)
Copyright © 2017, Juniper Networks, Inc.
273
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
request virtual-chassis routing-engine master switch
Syntax
Release Information
Description
request virtual-chassis routing-engine master switch
<check>
Command introduced in Junos OS Release 11.2.
Option check introduced in Junos OS Release 12.2.
Command introduced in Junos OS Release 13.2R2 for EX Series switches.
Change the mastership in an MX Series Virtual Chassis or EX9200 Virtual Chassis by
switching the global roles of the master router or switch and backup router or switch in
the Virtual Chassis configuration. The request virtual-chassis routing-engine master switch
command must be issued from the master router or switch (VC-Mm).
(MX Series routers only) The local roles (master and standby, or m and s) of the Routing
Engines in the Virtual Chassis master router change after a global switchover, but the
local roles of the Routing Engines in the Virtual Chassis backup router do not change. For
example, the master Routing Engine in the Virtual Chassis master router (VC-Mm)
becomes the standby Routing Engine in the Virtual Chassis backup router (VC-Bs) after
the global switchover. By contrast, the master Routing Engine in the Virtual Chassis
backup router (VC-Bm) remains the master Routing Engine in the Virtual Chassis master
router (VC-Mm) after the global switchover.
NOTE: Before you issue the request virtual-chassis routing-engine master
switch command from the master router or switch in the Virtual Chassis,
make sure that the system configuration is synchronized between the master
and backup router or switch. If the configuration is not synchronized, or if you
attempt to issue the request virtual-chassis routing-engine master switch
command from the backup router or switch instead of from the master router
or switch, the device displays an error message and rejects the command.
If you issue the request virtual-chassis routing-engine master switch command
when the Virtual Chassis is in a transition state (for example, the backup
router or switch is disconnecting from the Virtual Chassis), the device does
not process the command.
Options
check—(Optional) Perform a check from the master router or switch to determine whether
the member routers or switches are ready for GRES from a database synchronization
perspective, without initiating the GRES operation itself.
Required Privilege
Level
Related
Documentation
274
system-control
•
Switching the Global Master and Backup Roles in a Virtual Chassis Configuration on
page 95
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
List of Sample Output
•
Determining GRES Readiness in a Virtual Chassis Configuration on page 185
•
Switchover Behavior in an MX Series Virtual Chassis on page 34
•
Mastership Election in a Virtual Chassis on page 32
request virtual-chassis routing-engine master switch (From Master Router) on page 275
request virtual-chassis routing-engine master switch (Error When Configuration Not
Synchronized) on page 275
request virtual-chassis routing-engine master switch (Error When Run from Backup
Router) on page 275
request virtual-chassis routing-engine master switch check (Ready for
GRES) on page 275
request virtual-chassis routing-engine master switch check (Not Ready for
GRES) on page 275
Sample Output
request virtual-chassis routing-engine master switch (From Master Router)
{master:member0-re0}
user@host> request virtual-chassis routing-engine master switch
Do you want to continue ? [yes,no] (no)
request virtual-chassis routing-engine master switch (Error When Configuration Not Synchronized)
{master:member0-re0}
user@host> request virtual-chassis routing-engine master switch
Error: mastership switch request NOT honored, backup not ready
request virtual-chassis routing-engine master switch (Error When Run from Backup Router)
{backup:member1-re0}
user@host> request virtual-chassis routing-engine master switch
error: Virtual Chassis member is not the protocol master
request virtual-chassis routing-engine master switch check (Ready for GRES)
{master:member0-re0}
user@host> request virtual-chassis routing-engine master switch check
Switchover Ready
request virtual-chassis routing-engine master switch check (Not Ready for GRES)
{master:member0-re0}
user@host> request virtual-chassis routing-engine master switch check
error: chassisd Not ready for mastership switch, try after 217 secs.
mastership switch request NOT honored, backup not ready
Copyright © 2017, Juniper Networks, Inc.
275
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
request virtual-chassis vc-port delete (MX Series Virtual Chassis)
Syntax
Release Information
Description
request virtual-chassis vc-port delete fpc-slot fpc-slot-number pic-slot pic-slot-number port
port-number
<(local | member member-id)>
Command introduced in Junos OS Release 11.2.
Remove (delete) a Virtual Chassis port from a member router in an MX Series Virtual
Chassis configuration. After a Virtual Chassis port is created, it is renamed
vcp-slot/pic/port, and is no longer available for configuration as a standard network port.
After you remove a Virtual Chassis port, it becomes available to the global configuration
and can again function as a standard network port.
NOTE: If the member ID has not been set on the router where you issue the
request virtual-chassis vc-port delete command, the software prevents the
removal of the Virtual Chassis port on the router. To set the member ID, use
the request virtual-chassis member-id set command.
Options
fpc-slot fpc-slot-number—Number of the Flexible PIC Concentrator (FPC) slot on which
the Virtual Chassis port resides. The slot number corresponds to the Modular Port
Concentrator (MPC) slot number. Replace fpc-slot-number with a value appropriate
for your router:
•
MX960 router—0 through 11.
•
MX480 router—0 through 5.
•
MX240 router—0 through 2.
pic-slot pic-slot-number—Number of the PIC slot on which the Virtual Chassis port resides.
Replace pic-slot-number with a value in the range 0 through 3.
port port-number—Number of the port on the PIC on which the Virtual Chassis port resides.
Replace port-number with a value appropriate for your PIC.
local—(Optional) Delete the Virtual Chassis port on the member router on which you are
issuing the command. This is the default behavior if you do not specify the local or
member options.
member member-id—(Optional) Numeric value that identifies the remote Virtual Chassis
member on which you want to delete the Virtual Chassis port. Replace member-id
with the value 0 or 1.
Required Privilege
Level
276
system-control
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Related
Documentation
List of Sample Output
•
Deleting Virtual Chassis Ports in a Virtual Chassis Configuration on page 138
•
Example: Deleting a Virtual Chassis Configuration for MX Series 3D Universal Edge
Routers on page 111
request virtual-chassis vc-port delete (Remove vcp-3/2/1) on page 277
Sample Output
request virtual-chassis vc-port delete (Remove vcp-3/2/1)
user@host> request virtual-chassis vc-port delete fpc-slot 3 pic-slot 2 port 1
vc-port successfully deleted
Copyright © 2017, Juniper Networks, Inc.
277
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
request virtual-chassis vc-port set (MX Series Virtual Chassis)
Syntax
Release Information
Description
request virtual-chassis vc-port set fpc-slot fpc-slot-number pic-slot pic-slot-number port
port-number
<(local | member member-id)>
Command introduced in Junos OS Release 11.2.
Create (set) a Virtual Chassis port on an MX Series router through which the router
connects to other member routers in the Virtual Chassis. You can create Virtual Chassis
ports only on Modular Port Concentrator/Modular Interface Card (MPC/MIC) network
ports on MX Series routers.
After a Virtual Chassis port is created, it is renamed vcp-slot/pic/port, and is no longer
available for configuration as a standard network port. Virtual Chassis ports can be used
only to interconnect the MX Series routers in the Virtual Chassis.
NOTE: If the member ID has not been set on the router where you issue the
request virtual-chassis vc-port set command, the software prevents the
creation of the Virtual Chassis port on the router. To set the member ID, use
the request virtual-chassis member-id set command.
Options
fpc-slot fpc-slot-number—Number of the Flexible PIC Concentrator (FPC) slot on which
the Virtual Chassis port resides. The slot number corresponds to the Modular Port
Concentrator (MPC) slot number. Replace fpc-slot-number with a value appropriate
for your router:
•
MX960 router—0 through 11.
•
MX480 router—0 through 5.
•
MX240 router—0 through 2.
When you issue the show interfaces command on a member router in an MX Series
Virtual Chassis, the FPC slot number displayed in the command output reflects the
FPC slot numbering and offset used in the Virtual Chassis instead of the physical
slot number where the FPC is actually installed. The router with member ID 0 in the
Virtual Chassis uses FPC slot numbers 0 through 11 with no offset, and the router
with member ID 1 uses FPC slot numbers 12 through 23, with an offset of 12. For
example, a 10-Gigabit Ethernet interface that appears as xe-14/2/2 (FPC slot 14, PIC
slot 2, port 2) in the show interfaces command is actually interface xe-2/2/2 (FPC
slot 2, PIC slot 2, port 2) on member ID 1 after deducting the FPC slot numbering
offset of 12 for member ID 1.
pic-slot pic-slot-number—Number of the PIC slot on which the Virtual Chassis port resides.
Replace pic-slot-number with a value in the range 0 through 3.
278
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
port port-number—Number of the port on the PIC on which the Virtual Chassis port resides.
Replace port-number with a value appropriate for your PIC.
local—(Optional) Set the Virtual Chassis port on the member router on which you are
issuing the command. This is the default behavior if you do not specify the local or
member options.
member member-id—(Optional) Numeric value that identifies the remote Virtual Chassis
member on which you want to create the Virtual Chassis port. Replace member-id
with the value 0 or 1.
Required Privilege
Level
Related
Documentation
List of Sample Output
system-control
•
Configuring Virtual Chassis Ports to Interconnect Member Routers or Switches on
page 136
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Guidelines for Configuring Virtual Chassis Ports on page 134
request virtual-chassis vc-port set (No Existing Network Port) on page 279
request virtual-chassis vc-port set (Existing Network Port Converted) on page 279
request virtual-chassis vc-port set (On Local Router) on page 279
request virtual-chassis vc-port set (On Remote Member Router 1) on page 279
Sample Output
request virtual-chassis vc-port set (No Existing Network Port)
user@host> request virtual-chassis vc-port set fpc-slot 1 pic-slot 1 port 0
vc-port successfully set
request virtual-chassis vc-port set (Existing Network Port Converted)
user@host> request virtual-chassis vc-port set fpc-slot 2 pic-slot 1 port 1
Port conversion initiated, use “show virtual chassis vc-port” to verify
request virtual-chassis vc-port set (On Local Router)
user@host> request virtual-chassis vc-port set fpc-slot 2 pic-slot 1 port 3 local
vc-port successfully set
request virtual-chassis vc-port set (On Remote Member Router 1)
user@host> request virtual-chassis vc-port set fpc-slot 5 pic-slot 3 port 10 member 1
vc-port successfully set
Copyright © 2017, Juniper Networks, Inc.
279
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show chassis network-services
Syntax
show chassis network-services
Release Information
Command introduced in Junos OS Release 9.4.
Command introduced in Junos OS Release 12.3 for MX2010 3D Universal Edge Routers.
Command introduced in Junos OS Release 12.3 for MX2020 3D Universal Edge Routers.
Command introduced in Junos OS Release 13.2 for MX104 3D Universal Edge Routers.
Command introduced in Junos OS Release 15.F5 for PTX Series Routers with
third-generation FPCs.
Command introduced in Junos OS Release 17.2 for PTX10008 Routers.
Command introduced in Junos OS Release 17.2 for MX2008 3D Universal Edge Routers.
Description
Display the network services mode that the router is configured to run in—IP Network
Services mode, Ethernet Network Services mode, Enhanced IP Network Services mode,
Enhanced Ethernet Network Services mode, or Enhanced mode.
Options
This command has no options.
Required Privilege
Level
view
Related
Documentation
•
enhanced-mode
List of Sample Output
show chassis network services on page 281
show chassis network services (MX104 Router) on page 281
show chassis network services (MX2010 Router) on page 281
show chassis network services (MX2020 Router) on page 281
show chassis network services (MX2008 Router) on page 281
show chassis network services (PTX Router with third-generation FPCs) on page 281
Output Fields
Table 28 on page 280 lists the output fields for the show chassis network services command.
Output fields are listed in the approximate order in which they appear.
Table 28: show chassis network services Output Fields
Field Name
Field Description
Network Services Mode
Network services mode configured for the router:
•
IP—IP Network Services mode.
•
Ethernet—Ethernet Network Services mode.
•
enhanced-ip—Enhanced IP Network Services mode
•
enhanced-ethernet—Enhanced Ethernet Network Services mode
•
Enhanced-Mode—Enhanced mode for PTX Series routers that have third-generation FPCs installed.
See enhanced-mode.
280
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Sample Output
show chassis network services
user@host> show chassis network services
Network Services Mode: IP
show chassis network services (MX104 Router)
user@host> show chassis network services
Network Services Mode: IP
show chassis network services (MX2010 Router)
user@host> show chassis network services
Network Services Mode: Enhanced-IP
show chassis network services (MX2020 Router)
user@host> show chassis network services
Network Services Mode: Enhanced-IP
show chassis network services (MX2008 Router)
user@host> show chassis network-services
Network Services Mode: Enhanced-IP
show chassis network services (PTX Router with third-generation FPCs)
user@host> show chassis network services
Network Services Mode: Enhanced-Mode
Copyright © 2017, Juniper Networks, Inc.
281
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show interfaces vcp
Syntax
Release Information
Description
show interfaces vcp-fpc/pic/port
<brief | detail | extensive | terse>
<descriptions>
<media>
<snmp-index snmp-index>
<statistics>
Command introduced in Junos OS Release 11.4.
Display status information about the specified Virtual Chassis Port.
NOTE: This command only displays the statistics for the local interface of
the router that you are directly logged in to. You cannot display interface
status information of other member routers.
Options
vcp-fpc/pic/port —Display standard information about the specified Virtual Chassis Port.
brief | detail | extensive | terse—(Optional) Display the specified level of output.
descriptions—(Optional) Display interface description strings.
media—(Optional) Display media-specific information about network interfaces.
snmp-index snmp-index—(Optional) Display information for the specified SNMP index
of the interface.
statistics—(Optional) Display static interface statistics.
Additional Information
Required Privilege
Level
Related
Documentation
List of Sample Output
282
In a logical system, this command displays information only about the logical interfaces
and not about the physical interfaces.
view
•
Guidelines for Configuring Virtual Chassis Ports on page 134
•
show virtual-chassis protocol interface (MX Series Virtual Chassis) on page 321
show interfaces vcp (specific interface) on page 297
show interfaces vcp brief (specific interface) on page 298
show interfaces vcp detail (specific interface) on page 298
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 29:
Output
show
Fields
interfaces vcp Output Fields
Field Name
Field Description
Level of Output
Physical Interface
Name of the physical interface.
All levels
Enabled
State of the interface. Possible values are described in the “Enabled Field”
section under Common Output Fields Description.
All levels
Interface index
Index number of the physical interface, which reflects its initialization sequence.
detail extensive none
SNMP ifIndex
SNMP index number for the physical interface.
detail extensive none
Generation
Unique number for use by Juniper Networks technical support only.
detail extensive
Link-level type
Encapsulation being used on the physical interface.
All levels
MTU
Maximum transmission unit size on the physical interface.
All levels
Speed
Speed at which the interface is running.
All levels
Loopback
Loopback status: Enabled or Disabled. If loopback is enabled, type of loopback:
Local or Remote.
All levels
Source filtering
Source filtering status: Enabled or Disabled.
All levels
LAN-PHY mode
10-Gigabit Ethernet interface operating in Local Area Network Physical Layer
Device (LAN PHY) mode. LAN PHY allows 10-Gigabit Ethernet wide area links
to use existing Ethernet applications.
All levels
WAN-PHY mode
10-Gigabit Ethernet interface operating in Wide Area Network Physical Layer
Device (WAN PHY) mode. WAN PHY allows 10-Gigabit Ethernet wide area links
to use fiber-optic cables and other devices intended for SONET/SDH.
All levels
Unidirectional
Unidirectional link mode status for 10-Gigabit Ethernet interface: Enabled or
Disabled for parent interface; Rx-only or Tx-only for child interfaces.
All levels
Flow control
Flow control status: Enabled or Disabled.
All levels
Auto-negotiation
(Gigabit Ethernet interfaces) Autonegotiation status: Enabled or Disabled.
All levels
Remote-fault
(Gigabit Ethernet interfaces) Remote fault status:
All levels
Physical Interface
•
Online—Autonegotiation is manually configured as online.
•
Offline—Autonegotiation is manually configured as offline.
Device flags
Information about the physical device. Possible values are described in the
“Device Flags” section under Common Output Fields Description.
All levels
Interface flags
Information about the interface. Possible values are described in the “Interface
Flags” section under Common Output Fields Description.
All levels
Copyright © 2017, Juniper Networks, Inc.
283
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
Link flags
Information about the link. Possible values are described in the “Links Flags”
section under Common Output Fields Description.
All levels
Wavelength
(10-Gigabit Ethernet dense wavelength-division multiplexing [DWDM]
interfaces) Displays the configured wavelength, in nanometers (nm).
All levels
Frequency
(10-Gigabit Ethernet DWDM interfaces only) Displays the frequency associated
with the configured wavelength, in terahertz (THz).
All levels
CoS queues
Number of CoS queues configured.
detail extensive none
Schedulers
(Gigabit Ethernet intelligent queuing 2 [IQ2] interfaces only) Number of CoS
schedulers configured.
extensive
Hold-times
Current interface hold-time up and hold-time down, in milliseconds (ms).
detail extensive
Current address
Configured MAC address.
detail extensive none
Hardware address
Hardware MAC address.
detail extensive none
Last flapped
Date, time, and how long ago the interface went from down to up. The format
is Last flapped: year-month-day hour:minute:second:timezone (hour:minute:second
ago). For example, Last flapped: 2002-04-26 10:52:40 PDT (04:33:20 ago).
detail extensive none
Input Rate
Input rate in bits per second (bps) and packets per second (pps). The value in
this field also includes the Layer 2 overhead bytes for ingress traffic on Ethernet
interfaces if you enable accounting of Layer 2 overhead at the PIC level or the
logical interface level.
None
Output Rate
Output rate in bps and pps. The value in this field also includes the Layer 2
overhead bytes for egress traffic on Ethernet interfaces if you enable accounting
of Layer 2 overhead at the PIC level or the logical interface level.
None
Statistics last
cleared
Time when the statistics for the interface were last set to zero.
detail extensive
Egress account
overhead
Layer 2 overhead in bytes that is accounted in the interface statistics for egress
traffic.
detail extensive
Ingress account
overhead
Layer 2 overhead in bytes that is accounted in the interface statistics for ingress
traffic.
detail extensive
284
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
Traffic statistics
Number and rate of bytes and packets received and transmitted on the physical
interface.
detail extensive
•
Input bytes—Number of bytes received on the interface. The value in this field
also includes the Layer 2 overhead bytes for ingress traffic on Ethernet
interfaces if you enable accounting of Layer 2 overhead at the PIC level or
the logical interface level.
•
Output bytes—Number of bytes transmitted on the interface. The value in
this field also includes the Layer 2 overhead bytes for egress traffic on Ethernet
interfaces if you enable accounting of Layer 2 overhead at the PIC level or
the logical interface level.
•
Input packets—Number of packets received on the interface.
•
Output packets—Number of packets transmitted on the interface.
Gigabit Ethernet and 10-Gigabit Ethernet IQ PICs count the overhead and CRC
bytes.
For Gigabit Ethernet IQ PICs, the input byte counts vary by interface type. For
more information, see Table 31 under the show interfaces (10-Gigabit Ethernet)
command.
Input errors
Input errors on the interface. The following paragraphs explain the counters
whose meaning might not be obvious:
•
Errors—Sum of the incoming frame aborts and FCS errors.
•
Drops—Number of packets dropped by the input queue of the I/O Manager
extensive
ASIC. If the interface is saturated, this number increments once for every
packet that is dropped by the ASIC's RED mechanism.
•
Framing errors—Number of packets received with an invalid frame checksum
(FCS).
•
Runts—Number of frames received that are smaller than the runt threshold.
•
Policed discards—Number of frames that the incoming packet match code
discarded because they were not recognized or not of interest. Usually, this
field reports protocols that Junos OS does not handle.
•
L3 incompletes—Number of incoming packets discarded because they failed
Layer 3 (usually IPv4) sanity checks of the header. For example, a frame with
less than 20 bytes of available IP header is discarded. L3 incomplete errors
can be ignored by configuring the ignore-l3-incompletes statement.
•
L2 channel errors—Number of times the software did not find a valid logical
interface for an incoming frame.
•
L2 mismatch timeouts—Number of malformed or short packets that caused
the incoming packet handler to discard the frame as unreadable.
•
FIFO errors—Number of FIFO errors in the receive direction that are reported
by the ASIC on the PIC. If this value is ever nonzero, the PIC is probably
malfunctioning.
•
Resource errors—Sum of transmit drops.
Copyright © 2017, Juniper Networks, Inc.
285
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
Output errors
Output errors on the interface. The following paragraphs explain the counters
whose meaning might not be obvious:
extensive
•
Carrier transitions—Number of times the interface has gone from down to up.
This number does not normally increment quickly, increasing only when the
cable is unplugged, the far-end system is powered down and then up, or
another problem occurs. If the number of carrier transitions increments quickly
(perhaps once every 10 seconds), the cable, the far-end system, or the PIC
or PIM is malfunctioning.
•
Errors—Sum of the outgoing frame aborts and FCS errors.
•
Drops—Number of packets dropped by the output queue of the I/O Manager
ASIC. If the interface is saturated, this number increments once for every
packet that is dropped by the ASIC's RED mechanism.
NOTE: Due to accounting space limitations on certain Type 3 FPCs (which
are supported in M320 and T640 routers), the Drops field does not always
use the correct value for queue 6 or queue 7 for interfaces on 10-port 1-Gigabit
Ethernet PICs.
•
Collisions—Number of Ethernet collisions. The Gigabit Ethernet PIC supports
only full-duplex operation, so for Gigabit Ethernet PICs, this number should
always remain 0. If it is nonzero, there is a software bug.
•
Aged packets—Number of packets that remained in shared packet SDRAM
so long that the system automatically purged them. The value in this field
should never increment. If it does, it is most likely a software bug or possibly
malfunctioning hardware.
•
FIFO errors—Number of FIFO errors in the send direction as reported by the
ASIC on the PIC. If this value is ever nonzero, the PIC is probably
malfunctioning.
•
HS link CRC errors—Number of errors on the high-speed links between the
ASICs responsible for handling the router interfaces.
Egress queues
•
MTU errors—Number of packets whose size exceeded the MTU of the interface.
•
Resource errors—Sum of transmit drops.
Total number of egress queues supported on the specified interface.
detail extensive
NOTE: In DPCs that are not of the enhanced type, such as DPC 40x 1GE R, DPCE
20x 1GE + 2x 10GE R, or DPCE 40x 1GE R, you might notice a discrepancy in the
output of the show interfaces command because incoming packets might be
counted in the Egress queues section of the output. This problem occurs on
non-enhanced DPCs because the egress queue statistics are polled from IMQ
(Inbound Message Queuing) block of the I-chip. The IMQ block does not
differentiate between ingress and egress WAN traffic; as a result, the combined
statistics are displayed in the egress queue counters on the Routing Engine. In
a simple VPLS scenorio, if there is no MAC entry in DMAC table (by sending
unidirectional traffic), traffic is flooded and the input traffic is accounted in IMQ.
For bidirectional traffic (MAC entry in DMAC table), if the outgoing interface is
on the same I-chip then both ingress and egress statistics are counted in a
combined way. If the outgoing interface is on a different I-chip or FPC, then only
egress statistics are accounted in IMQ. This behavior is expected with
non-enhanced DPCs
286
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
Queue counters
(Egress)
CoS queue number and its associated user-configured forwarding class name.
detail extensive
•
Queued packets—Number of queued packets.
•
Transmitted packets—Number of transmitted packets.
•
Dropped packets—Number of packets dropped by the ASIC's RED mechanism.
NOTE: Due to accounting space limitations on certain Type 3 FPCs (which
are supported in M320 and T640 routers), the Dropped packets field does not
always display the correct value for queue 6 or queue 7 for interfaces on
10-port 1-Gigabit Ethernet PICs.
Ingress queues
Total number of ingress queues supported on the specified interface. Displayed
on IQ2 interfaces.
extensive
Queue counters
(Ingress)
CoS queue number and its associated user-configured forwarding class name.
Displayed on IQ2 interfaces.
extensive
Active alarms and
Active defects
•
Queued packets—Number of queued packets.
•
Transmitted packets—Number of transmitted packets.
•
Dropped packets—Number of packets dropped by the ASIC's RED mechanism.
Ethernet-specific defects that can prevent the interface from passing packets.
When a defect persists for a certain amount of time, it is promoted to an alarm.
Based on the router configuration, an alarm can ring the red or yellow alarm
bell on the router, or turn on the red or yellow alarm LED on the craft interface.
These fields can contain the value None or Link.
•
None—There are no active defects or alarms.
•
Link—Interface has lost its link state, which usually means that the cable is
detail extensive none
unplugged, the far-end system has been turned off, or the PIC is
malfunctioning.
Interface transmit
statistics
(On MX Series devices) Status of the interface-transmit-statistics configuration:
Enabled or Disabled.
•
detail extensive
Enabled—When the interface-transmit-statistics statement is included in the
configuration. If this is configured, the interface statistics show the actual
transmitted load on the interface.
•
Disabled—When the interface-transmit-statistics statement is not included
in the configuration. If this is not configured, the interface statistics show the
offered load on the interface.
OTN FEC statistics
The forward error correction (FEC) counters provide the following statistics:
•
Corrected Errors—The count of corrected errors in the last second.
•
Corrected Error Ratio—The corrected error ratio in the last 25 seconds. For
detail extensive
example, 1e-7 is 1 error per 10 million bits.
Copyright © 2017, Juniper Networks, Inc.
287
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
PCS statistics
(10-Gigabit Ethernet interfaces) Displays Physical Coding Sublayer (PCS) fault
conditions from the WAN PHY or the LAN PHY device.
detail extensive
•
Bit errors—The number of seconds during which at least one bit error rate
(BER) occurred while the PCS receiver is operating in normal mode.
•
Errored blocks—The number of seconds when at least one errored block
occurred while the PCS receiver is operating in normal mode.
288
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
MAC statistics
Receive and Transmit statistics reported by the PIC's MAC subsystem, including
extensive
the following:
•
Total octets and total packets—Total number of octets and packets. For
Gigabit Ethernet IQ PICs, the received octets count varies by interface type.
For more information, see Table 31 under the show interfaces (10-Gigabit
Ethernet) command.
•
Unicast packets, Broadcast packets, and Multicast packets—Number of unicast,
broadcast, and multicast packets.
•
CRC/Align errors—Total number of packets received that had a length
(excluding framing bits, but including FCS octets) of between 64 and 1518
octets, inclusive, and had either a bad FCS with an integral number of octets
(FCS Error) or a bad FCS with a nonintegral number of octets (Alignment
Error).
•
FIFO error—Number of FIFO errors that are reported by the ASIC on the PIC.
If this value is ever nonzero, the PIC or a cable is probably malfunctioning.
•
MAC control frames—Number of MAC control frames.
•
MAC pause frames—Number of MAC control frames with pause operational
code.
•
Oversized frames—There are two possible conditions regarding the number
of oversized frames:
•
•
Packet length exceeds 1518 octets, or
•
Packet length exceeds MRU
Jabber frames—Number of frames that were longer than 1518 octets (excluding
framing bits, but including FCS octets), and had either an FCS error or an
alignment error. This definition of jabber is different from the definition in
IEEE-802.3 section 8.2.1.5 (10BASE5) and section 10.3.1.4 (10BASE2). These
documents define jabber as the condition in which any packet exceeds 20
ms. The allowed range to detect jabber is from 20 ms to 150 ms.
•
Fragment frames—Total number of packets that were less than 64 octets in
length (excluding framing bits, but including FCS octets) and had either an
FCS error or an alignment error. Fragment frames normally increment because
both runts (which are normal occurrences caused by collisions) and noise
hits are counted.
•
VLAN tagged frames—Number of frames that are VLAN tagged. The system
uses the TPID of 0x8100 in the frame to determine whether a frame is tagged
or not.
NOTE: The 20-port Gigabit Ethernet MIC (MIC-3D-20GE-SFP) does not have
hardware counters for VLAN frames. Therefore, the VLAN tagged frames field
displays 0 when the show interfaces command is executed on a 20-port
Gigabit Ethernet MIC. In other words, the number of VLAN tagged frames
cannot be determined for the 20-port Gigabit Ethernet MIC.
•
Code violations—Number of times an event caused the PHY to indicate “Data
reception error” or “invalid data symbol error.”
OTN Received
Overhead Bytes
APS/PCC0: 0x02, APS/PCC1: 0x11, APS/PCC2: 0x47, APS/PCC3: 0x58 Payload
Type: 0x08
extensive
OTN Transmitted
Overhead Bytes
APS/PCC0: 0x00, APS/PCC1: 0x00, APS/PCC2: 0x00, APS/PCC3: 0x00
Payload Type: 0x08
extensive
Copyright © 2017, Juniper Networks, Inc.
289
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
Filter statistics
Receive and Transmit statistics reported by the PIC's MAC address filter
extensive
subsystem. The filtering is done by the content-addressable memory (CAM)
on the PIC. The filter examines a packet's source and destination MAC addresses
to determine whether the packet should enter the system or be rejected.
•
Input packet count—Number of packets received from the MAC hardware
that the filter processed.
•
Input packet rejects—Number of packets that the filter rejected because of
either the source MAC address or the destination MAC address.
•
Input DA rejects—Number of packets that the filter rejected because the
destination MAC address of the packet is not on the accept list. It is normal
for this value to increment. When it increments very quickly and no traffic is
entering the router from the far-end system, either there is a bad ARP entry
on the far-end system, or multicast routing is not on and the far-end system
is sending many multicast packets to the local router (which the router is
rejecting).
•
Input SA rejects—Number of packets that the filter rejected because the
source MAC address of the packet is not on the accept list. The value in this
field should increment only if source MAC address filtering has been enabled.
If filtering is enabled, if the value increments quickly, and if the system is not
receiving traffic that it should from the far-end system, it means that the
user-configured source MAC addresses for this interface are incorrect.
•
Output packet count—Number of packets that the filter has given to the MAC
hardware.
•
Output packet pad count—Number of packets the filter padded to the
minimum Ethernet size (60 bytes) before giving the packet to the MAC
hardware. Usually, padding is done only on small ARP packets, but some very
small IP packets can also require padding. If this value increments rapidly,
either the system is trying to find an ARP entry for a far-end system that does
not exist or it is misconfigured.
•
Output packet error count—Number of packets with an indicated error that
the filter was given to transmit. These packets are usually aged packets or
are the result of a bandwidth problem on the FPC hardware. On a normal
system, the value of this field should not increment.
•
CAM destination filters, CAM source filters—Number of entries in the CAM
dedicated to destination and source MAC address filters. There can only be
up to 64 source entries. If source filtering is disabled, which is the default, the
values for these fields should be 0.
PMA PHY
(10-Gigabit Ethernet interfaces, WAN PHY mode) SONET error information:
•
Seconds—Number of seconds the defect has been active.
•
Count—Number of times that the defect has gone from inactive to active.
•
State—State of the error. Any state other than OK indicates a problem.
extensive
Subfields are:
290
•
PHY Lock—Phase-locked loop
•
PHY Light—Loss of optical signal
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
WIS section
(10-Gigabit Ethernet interfaces, WAN PHY mode) SONET error information:
extensive
•
Seconds—Number of seconds the defect has been active.
•
Count—Number of times that the defect has gone from inactive to active.
•
State—State of the error. Any state other than OK indicates a problem.
Subfields are:
WIS line
•
BIP-B1—Bit interleaved parity for SONET section overhead
•
SEF—Severely errored framing
•
LOL—Loss of light
•
LOF—Loss of frame
•
ES-S—Errored seconds (section)
•
SES-S—Severely errored seconds (section)
•
SEFS-S—Severely errored framing seconds (section)
(10-Gigabit Ethernet interfaces, WAN PHY mode) Active alarms and defects,
plus counts of specific SONET errors with detailed information:
•
Seconds—Number of seconds the defect has been active.
•
Count—Number of times that the defect has gone from inactive to active.
•
State—State of the error. Any state other than OK indicates a problem.
extensive
Subfields are:
•
BIP-B2—Bit interleaved parity for SONET line overhead
•
REI-L—Remote error indication (near-end line)
•
RDI-L—Remote defect indication (near-end line)
•
AIS-L—Alarm indication signal (near-end line)
•
BERR-SF—Bit error rate fault (signal failure)
•
BERR-SD—Bit error rate defect (signal degradation)
•
ES-L—Errored seconds (near-end line)
•
SES-L—Severely errored seconds (near-end line)
•
UAS-L—Unavailable seconds (near-end line)
•
ES-LFE—Errored seconds (far-end line)
•
SES-LFE—Severely errored seconds (far-end line)
•
UAS-LFE—Unavailable seconds (far-end line)
Copyright © 2017, Juniper Networks, Inc.
291
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
WIS path
(10-Gigabit Ethernet interfaces, WAN PHY mode) Active alarms and defects,
plus counts of specific SONET errors with detailed information:
extensive
•
Seconds—Number of seconds the defect has been active.
•
Count—Number of times that the defect has gone from inactive to active.
•
State—State of the error. Any state other than OK indicates a problem.
Subfields are:
292
•
BIP-B3—Bit interleaved parity for SONET section overhead
•
REI-P—Remote error indication
•
LOP-P—Loss of pointer (path)
•
AIS-P—Path alarm indication signal
•
RDI-P—Path remote defect indication
•
UNEQ-P—Path unequipped
•
PLM-P—Path payload (signal) label mismatch
•
ES-P—Errored seconds (near-end STS path)
•
SES-P—Severely errored seconds (near-end STS path)
•
UAS-P—Unavailable seconds (near-end STS path)
•
SES-PFE—Severely errored seconds (far-end STS path)
•
UAS-PFE—Unavailable seconds (far-end STS path)
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
Autonegotiation
information
Information about link autonegotiation.
extensive
•
Negotiation status:
•
Incomplete—Ethernet interface has the speed or link mode configured.
•
No autonegotiation—Remote Ethernet interface has the speed or link mode
configured, or does not perform autonegotiation.
•
Complete—Ethernet interface is connected to a device that performs
autonegotiation and the autonegotiation process is successful.
•
Link partner status—OK when Ethernet interface is connected to a device that
performs autonegotiation and the autonegotiation process is successful.
•
Link partner—Information from the remote Ethernet device:
•
Link mode—Depending on the capability of the link partner, either
Full-duplex or Half-duplex.
•
Flow control—Types of flow control supported by the link partner. For
Gigabit Ethernet interfaces, types are Symmetric (link partner supports
PAUSE on receive and transmit), Asymmetric (link partner supports PAUSE
on transmit), Symmetric/Asymmetric (link partner supports PAUSE on
receive and transmit or only PAUSE on transmit), and None (link partner
does not support flow control).
•
Remote fault—Remote fault information from the link partner—Failure
indicates a receive link error. OK indicates that the link partner is receiving.
Negotiation error indicates a negotiation error. Offline indicates that the
link partner is going offline.
•
Local resolution—Information from the local Ethernet device:
•
Flow control—Types of flow control supported by the local device. For
Gigabit Ethernet interfaces, advertised capabilities are
Symmetric/Asymmetric (local device supports PAUSE on receive and
transmit or only PAUSE on receive) and None (local device does not support
flow control). Depending on the result of the negotiation with the link
partner, local resolution flow control type will display Symmetric (local
device supports PAUSE on receive and transmit), Asymmetric (local device
supports PAUSE on receive), and None (local device does not support flow
control).
•
Remote fault—Remote fault information. Link OK (no error detected on
receive), Offline (local interface is offline), and Link Failure (link error
detected on receive).
Received path
trace, Transmitted
path trace
(10-Gigabit Ethernet interfaces, WAN PHY mode) SONET/SDH interfaces allow
path trace bytes to be sent inband across the SONET/SDH link. Juniper Networks
and other router manufacturers use these bytes to help diagnose
misconfigurations and network errors by setting the transmitted path trace
message so that it contains the system hostname and name of the physical
interface. The received path trace value is the message received from the router
at the other end of the fiber. The transmitted path trace value is the message
that this router transmits.
extensive
Packet Forwarding
Engine
configuration
Information about the configuration of the Packet Forwarding Engine:
extensive
•
Destination slot—FPC slot number.
Copyright © 2017, Juniper Networks, Inc.
293
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
CoS information
Information about the CoS queue for the physical interface.
extensive
•
CoS transmit queue—Queue number and its associated user-configured
forwarding class name.
•
Bandwidth %—Percentage of bandwidth allocated to the queue.
•
Bandwidth bps—Bandwidth allocated to the queue (in bps).
•
Buffer %—Percentage of buffer space allocated to the queue.
•
Buffer usec—Amount of buffer space allocated to the queue, in microseconds.
This value is nonzero only if the buffer size is configured in terms of time.
•
Priority—Queue priority: low or high.
•
Limit—Displayed if rate limiting is configured for the queue. Possible values
are none and exact. If exact is configured, the queue transmits only up to the
configured bandwidth, even if excess bandwidth is available. If none is
configured, the queue transmits beyond the configured bandwidth if
bandwidth is available.
Logical Interface
Logical interface
Name of the logical interface.
All levels
Index
Index number of the logical interface, which reflects its initialization sequence.
detail extensive none
SNMP ifIndex
SNMP interface index number for the logical interface.
detail extensive none
Generation
Unique number for use by Juniper Networks technical support only.
detail extensive
Flags
Information about the logical interface. Possible values are described in the
“Logical Interface Flags” section under Common Output Fields Description.
All levels
294
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
VLAN-Tag
Rewrite profile applied to incoming or outgoing frames on the outer (Out) VLAN
tag or for both the outer and inner (In) VLAN tags.
brief detail extensive
•
push—An outer VLAN tag is pushed in front of the existing VLAN tag.
•
pop—The outer VLAN tag of the incoming frame is removed.
•
swap—The outer VLAN tag of the incoming frame is overwritten with the
none
user-specified VLAN tag information.
•
push—An outer VLAN tag is pushed in front of the existing VLAN tag.
•
push-push—Two VLAN tags are pushed in from the incoming frame.
•
swap-push—The outer VLAN tag of the incoming frame is replaced by a
user-specified VLAN tag value. A user-specified outer VLAN tag is pushed in
front. The outer tag becomes an inner tag in the final frame.
•
swap-swap—Both the inner and the outer VLAN tags of the incoming frame
are replaced by the user-specified VLAN tag value.
•
pop-swap—The outer VLAN tag of the incoming frame is removed, and the
inner VLAN tag of the incoming frame is replaced by the user-specified VLAN
tag value. The inner tag becomes the outer tag in the final frame.
•
pop-pop—Both the outer and inner VLAN tags of the incoming frame are
removed.
Demux
IP demultiplexing (demux) value that appears if this interface is used as the
demux underlying interface. The output is one of the following:
•
Source Family Inet
•
Destination Family Inet
detail extensive none
Encapsulation
Encapsulation on the logical interface.
All levels
ACI VLAN: Dynamic
Profile
Name of the dynamic profile that defines the agent circuit identifier (ACI)
interface set. If configured, the ACI interface set enables the underlying Ethernet
interface to create dynamic VLAN subscriber interfaces based on ACI
information.
brief detail extensive
Protocol
Protocol family. Possible values are described in the “Protocol Field” section
under Common Output Fields Description.
detail extensive none
MTU
Maximum transmission unit size on the logical interface.
detail extensive none
Dynamic Profile
(MX Series routers with Trio MPCs only) Name of the dynamic profile that was
used to create this interface configured with a Point-to-Point Protocol over
Ethernet (PPPoE) family.
detail extensive none
Service Name Table
(MX Series routers with Trio MPCs only) Name of the service name table for
the interface configured with a PPPoE family.
detail extensive none
Max Sessions
(MX Series routers with Trio MPCs only) Maximum number of PPPoE logical
interfaces that can be activated on the underlying interface.
detail extensive none
Copyright © 2017, Juniper Networks, Inc.
none
295
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
Duplicate
Protection
(MX Series routers with Trio MPCs only) State of PPPoE duplicate protection:
On or Off. When duplicate protection is configured for the underlying interface,
a dynamic PPPoE logical interface cannot be activated when an existing active
logical interface is present for the same PPPoE client.
detail extensive none
Direct Connect
State of the configuration to ignore DSL Forum VSAs: On or Off. When configured,
the router ignores any of these VSAs received from a directly connected CPE
device on the interface.
detail extensive none
AC Name
Name of the access concentrator.
detail extensive none
Maximum labels
Maximum number of MPLS labels configured for the MPLS protocol family on
the logical interface.
detail extensive none
Traffic statistics
Number and rate of bytes and packets received and transmitted on the specified
interface set.
detail extensive
•
Input bytes, Output bytes—Number of bytes received and transmitted on the
interface set. The value in this field also includes the Layer 2 overhead bytes
for ingress or egress traffic on Ethernet interfaces if you enable accounting
of Layer 2 overhead at the PIC level or the logical interface level.
•
Input packets, Output packets—Number of packets received and transmitted
on the interface set.
IPv6 transit
statistics
Number of IPv6 transit bytes and packets received and transmitted on the
logical interface if IPv6 statistics tracking is enabled.
extensive
Local statistics
Number and rate of bytes and packets destined to the router.
extensive
Transit statistics
Number and rate of bytes and packets transiting the switch.
extensive
NOTE: For Gigabit Ethernet intelligent queuing 2 (IQ2) interfaces, the logical
interface egress statistics might not accurately reflect the traffic on the wire
when output shaping is applied. Traffic management output shaping might
drop packets after they are tallied by the Output bytes and Output packets
interface counters. However, correct values display for both of these egress
statistics when per-unit scheduling is enabled for the Gigabit Ethernet IQ2
physical interface, or when a single logical interface is actively using a shared
scheduler.
Generation
Unique number for use by Juniper Networks technical support only.
detail extensive
Route Table
Route table in which the logical interface address is located. For example, 0
refers to the routing table inet.0.
detail extensive none
Flags
Information about protocol family flags. Possible values are described in the
“Family Flags” section under Common Output Fields Description.
detail extensive
Donor interface
(Unnumbered Ethernet) Interface from which an unnumbered Ethernet interface
borrows an IPv4 address.
detail extensive none
296
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 29: show interfaces vcp Output Fields (continued)
Field Name
Field Description
Level of Output
Preferred source
address
(Unnumbered Ethernet) Secondary IPv4 address of the donor loopback interface
that acts as the preferred source address for the unnumbered Ethernet interface.
detail extensive none
Input Filters
Names of any input filters applied to this interface. If you specify a precedence
value for any filter in a dynamic profile, filter precedence values appear in
parentheses next to all interfaces.
detail extensive
Output Filters
Names of any output filters applied to this interface. If you specify a precedence
value for any filter in a dynamic profile, filter precedence values appear in
parentheses next to all interfaces.
detail extensive
Mac-Validate
Failures
Number of MAC address validation failures for packets and bytes. This field is
displayed when MAC address validation is enabled for the logical interface.
detail extensive none
Addresses, Flags
Information about the address flags. Possible values are described in the
“Addresses Flags” section under Common Output Fields Description.
detail extensive none
protocol-family
Protocol family configured on the logical interface. If the protocol is inet, the IP
address of the interface is also displayed.
brief
Flags
Information about the address flag. Possible values are described in the
“Addresses Flags” section under Common Output Fields Description.
detail extensive none
Destination
IP address of the remote side of the connection.
detail extensive none
Local
IP address of the logical interface.
detail extensive none
Broadcast
Broadcast address of the logical interface.
detail extensive none
Generation
Unique number for use by Juniper Networks technical support only.
detail extensive
Sample Output
show interfaces vcp (specific interface)
user@host> show interfaces vcp-4/0/0
Physical interface: vcp-4/0/0, Enabled, Physical link is Up
Interface index: 128, SNMP ifIndex: 821
Link-level type: 70, MTU: 9148, Speed: 1000mbps
Device flags
: Present Running
Interface flags: Promiscuous Internal: 0x4000
Link flags
: None
CoS queues
: 8 supported, 8 maximum usable queues
Schedulers
: 0
Current address: Unspecified, Hardware address: Unspecified
Last flapped
: 2015-11-05 11:29:58 PST (10:39:25 ago)
Input rate
: 18232 bps (26 pps)
Output rate
: 17160 bps (25 pps)
Active alarms : None
Active defects : None
Interface transmit statistics: Disabled
Copyright © 2017, Juniper Networks, Inc.
297
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Logical interface vcp-4/0/0.32768 (Index 64) (SNMP ifIndex 822)
Flags: Encapsulation: Unspecified
show interfaces vcp brief (specific interface)
user@host> show interfaces vcp-4/0/0 brief
Physical interface: vcp-4/0/0, Enabled, Physical link is Up
Link-level type: 70, MTU: 9148, Speed: 1000mbps
Device flags
: Present Running
Interface flags: Promiscuous Internal: 0x4000
Link flags
: None
Logical interface vcp-4/0/0.32768
Flags: Down Encapsulation: Unspecified
show interfaces vcp detail (specific interface)
user@host> show interfaces vcp-4/0/0 detail
Physical interface: vcp-4/0/0, Enabled, Physical link is Up
Interface index: 128, SNMP ifIndex: 821, Generation: 131
Link-level type: 70, MTU: 9148, Speed: 1000mbps
Device flags
: Present Running
Interface flags: Promiscuous Internal: 0x4000
Link flags
: None
CoS queues
: 8 supported, 8 maximum usable queues
Schedulers
: 0
Hold-times
: Up 0 ms, Down 0 ms
Current address: Unspecified, Hardware address: Unspecified
Last flapped
: 2015-11-05 11:29:58 PST (10:40:23 ago)
Statistics last cleared: Never
Traffic statistics:
Input bytes :
74190791
12624 bps
Output bytes :
72984813
12080 bps
Input packets:
1050663
26 pps
Output packets:
1041055
26 pps
IPv6 transit statistics:
Input bytes :
0
Output bytes :
0
Input packets:
0
Output packets:
0
Egress queues: 8 supported, 4 in use
Queue counters:
Queued packets Transmitted packets
Dropped packets
0 best-effort
698
698
0
0
0
0
0
1 expedited-forwarding
0
2 assured-forwarding
0
3 network-control
298
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
1040348
1040348
0
Queue number:
Mapped forwarding classes
0
best-effort
1
expedited-forwarding
2
assured-forwarding
3
network-control
Active alarms : None
Active defects : None
Interface transmit statistics: Disabled
Logical interface vcp-4/0/0.32768 (Index 64) (SNMP ifIndex 822) (Generation
129)
Flags: Down Encapsulation: Unspecified
Copyright © 2017, Juniper Networks, Inc.
299
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show services accounting status
Syntax
show services accounting status
<inline-jflow fpc-slot slot-number | name (* | all | service-name)>
Release Information
Command introduced before Junos OS Release 7.4.
Command introduced in Junos OS Release 13.2R2 for EX Series switches.
Description
Display available Physical Interface Cards (PICs) for accounting services.
Options
none—Display available PICs for all accounting services.
inline-jflow fpc-slot slot-number—(Optional) Display inline flow accounting status for the
specified FPC. For a two-member MX Series Virtual Chassis or EX9200 Virtual
Chassis, the master router or switch uses FPC slot numbers 0 through 11 with no
offset; the backup router or switch uses FPC slot numbers 12 through 23, with an
offset of 12.
name (* | all | service-name)—(Optional) Display available PICs. Use a wildcard character,
specify all services, or provide a specific services name.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
view
•
show services accounting flow
•
Inline Flow Monitoring for Virtual Chassis Overview on page 191
show services accounting status name (Monitoring PIC Interface) on page 301
show services accounting status name (Service PIC Interface) on page 302
show services accounting status inline-jflow fpc-slot (When Both IPv4 and IPv6 Are
Configured) on page 302
show services accounting status inline-jflow (MX80 Router When Both IPv4 and IPv6
Are Configured) on page 302
show services accounting status inline-jflow fpc-slot (PTX1000 Router When Both
IPv4 and IPv6 Are Configured) on page 302
Table 30 on page 300 lists the output fields for the show services accounting status
command. Output fields are listed in the approximate order in which they appear.
Table 30: show services accounting status Output Fields
Field
Field Description
Service Accounting
interface
Name of the service accounting interface.
300
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 30: show services accounting status Output Fields (continued)
Field
Field Description
Service name
Name of a service that was configured at the [edit-forwarding-options accounting] hierarchy level.
The default display,(default sampling), indicates the service was configured at the
[edit-forwarding-options sampling-level] hierarchy level.
FPC Slot
Slot number of the FPC for which the flow information is displayed.
Local interface index
Index counter of the local interface.
Interface state
Accounting state of the passive monitoring interface.
•
Accounting—PIC is actively accounting.
•
Disabled—PIC has been disabled from the CLI.
•
Not accounting—PIC is up but not accounting. This can happen while the PIC is coming online, or
when the PIC is up but has no logical unit configured under the physical interface.
•
Unknown
Group index
Integer that represents the monitoring group of which the PIC is a member. Group index is a mapping
from the group name to an index. It is not related to the number of monitoring groups.
Export interval (in
seconds)
Configured export interval for cflowd records, in seconds.
Export format
Configured export format.
Protocol
Protocol the PIC is configured to monitor.
Engine type
Configured engine type that is inserted in output cflowd packets.
Engine ID
Configured engine ID that is inserted in output cflowd packets.
Route Record Count
Number of routes recorded.
AS Record Count
Number of autonomous systems recorded.
Route Records Set
Status of route recording; whether routes are recorded or not.
Configuration Set
Status of monitoring configuration; whether monitoring configuration is set or not.
Sample Output
show services accounting status name (Monitoring PIC Interface)
user@host> show services accounting status name count1
Service Accounting interface: mo-2/0/0, Local interface index: 468
Service name: count1
Interface state: Accounting
Group index: 0
Export interval (in seconds): 60, Export format: cflowd v8
Protocol: IPv4, Engine type: 55, Engine ID: 5
Copyright © 2017, Juniper Networks, Inc.
301
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Sample Output
show services accounting status name (Service PIC Interface)
user@host> show services accounting status name
Service Accounting interface: sp-0/1/0
Interface state: Accounting
Export format: 9, Route record count: 0
IFL to SNMP index count: 7, AS count: 0
Configuration set: Yes, Route record set: No, IFL SNMP map set: Yes
Service Accounting interface: sp-1/0/0
Interface state: Accounting
Export format: 9, Route record count: 33
IFL to SNMP index count: 7, AS count: 1
Configuration set: Yes, Route record set: Yes, IFL SNMP map set: Yes
show services accounting status inline-jflow fpc-slot (When Both IPv4 and IPv6 Are Configured)
user@host> show services accounting status inline-jflow fpc-slot 5
FPC Slot: 5
IPV4 export format: Version-IPFIX, IPV6 export format: Version-IPFIX
VPLS export format: Not set
IPv4 Route Record Count: 5, IPv6 Route Record Count: 7
Route Record Count: 12, AS Record Count: 1
Route-Records Set: Yes, Config Set: Yes
show services accounting status inline-jflow (MX80 Router When Both IPv4 and IPv6 Are Configured)
user@host> show services accounting status inline-jflow
Status information
TFEB Slot: 0
Export format: IP-FIX
IPv4 Route Record Count: 6, IPv6 Route Record Count: 8
Route Record Count: 14, AS Record Count: 1
Route-Records Set: Yes, Config Set: Yes
show services accounting status inline-jflow fpc-slot (PTX1000 Router When Both IPv4 and IPv6 Are Configured)
user@host> show services accounting status inline-jflow fpc-slot 0
Status information
FPC Slot: 0
IPV4 export format: Version-IPFIX, IPV6 export format: Version-IPFIX
VPLS export format: Not set, MPLS export format: Not set
IPv4 Route Record Count: 23, IPv6 Route Record Count: 3, MPLS Route Record Count:
0
Route Record Count: 26, AS Record Count: 1
Route-Records Set: Yes, Config Set: Yes
IPv4 MAX FLOW Count: 0, IPv6 MAX FLOW Count: 0
VPLS MAX FLOW Count: 0, MPLS MAX FLOW Count: 2
302
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
show virtual-chassis active-topology (MX Series Virtual Chassis)
Syntax
Release Information
Description
Options
show virtual-chassis active-topology
<(all-members | local | member member-id)>
Command introduced in Junos OS Release 11.2.
Display information about neighbor reachability from each member router in an MX Series
Virtual Chassis configuration. You can issue the show virtual-chassis active-topology
command from the console of either member router in the Virtual Chassis.
all-members—(Optional) Display neighbor reachability information for both member
routers in a Virtual Chassis configuration. This is the default behavior if no options
are specified.
local—(Optional) Display neighbor reachability information for the member router on
which you are issuing the command.
member member-id—(Optional) Display neighbor reachability information for the specified
Virtual Chassis member router. Replace member-id with the value 0 or 1.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
view
•
Verifying Neighbor Reachability for Member Routers or Switches in a Virtual Chassis
on page 184
show virtual-chassis active-topology all-members on page 304
show virtual-chassis active-topology local on page 304
show virtual-chassis active-topology member 1 on page 304
Table 31 on page 303 lists the output fields for the show virtual-chassis active-topology
command. Output fields are listed in the approximate order in which they appear.
Table 31: show virtual-chassis active-topology Output Fields
Field Name
Field Description
membern
Member ID of the Virtual Chassis member router for which output is displayed.
Destination ID
Member ID of the destination (neighbor) router.
Next-hop
Member ID and Virtual Chassis port interface (in the format vcp-slot/pic/port.logical-unit-number)
of the next-hop to which the router forwards packets for the destination ID.
Copyright © 2017, Juniper Networks, Inc.
303
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Sample Output
show virtual-chassis active-topology all-members
{master:member0-re0}
user@host> show virtual-chassis active-topology all-members
member0:
-------------------------------------------------------------------------Destination ID
Next-hop
1
1(vcp-5/0/0.32768)
member1:
-------------------------------------------------------------------------Destination ID
Next-hop
0
0(vcp-1/3/0.32768)
show virtual-chassis active-topology local
{master:member0-re0}
user@host> show virtual-chassis active-topology local
Destination ID
1
Next-hop
1(vcp-5/0/0.32768)
show virtual-chassis active-topology member 1
{master:member0-re0}
user@host> show virtual-chassis active-topology member 1
member1:
-------------------------------------------------------------------------Destination ID
Next-hop
0
304
0(vcp-1/3/0.32768)
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
show virtual-chassis device-topology (MX Series Virtual Chassis)
Syntax
Release Information
show virtual-chassis device-topology
<(all-members | local | member member-id)>
Command introduced in Junos OS Release 11.2.
Description
Display information about neighbor reachability for each hardware device in an MX Series
Virtual Chassis configuration. On the MX Series router, there is only one active device for
each member router. You can issue the show virtual-chassis device-topology command
from the console of either member router in the Virtual Chassis.
Options
all-members—(Optional) Display neighbor reachability information for the device in both
member routers in a Virtual Chassis configuration.
local—(Optional) Display neighbor reachability information for the device in the member
router on which you are issuing the command. This is the default behavior if no
options are specified.
member member-id—(Optional) Display neighbor reachability information for the device
in the specified Virtual Chassis member router. Replace member-id with the value 0
or 1.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
view
•
Verifying Neighbor Reachability for Hardware Devices in a Virtual Chassis on page 184
show virtual-chassis device-topology all-members on page 306
show virtual-chassis device-topology local on page 306
show virtual-chassis device-topology member 1 on page 306
Table 32 on page 305 lists the output fields for the show virtual-chassis device-topology
command. Output fields are listed in the approximate order in which they appear.
Table 32: show virtual-chassis device-topology Output Fields
Field Name
Field Description
membern
Member ID of the Virtual Chassis member router for which output is displayed.
Member
Identifier assigned to the member router in the preprovisioned Virtual Chassis configuration.
Device
Identifier assigned to the device in the member router.
Because there is only one active device per member router in an MX Series Virtual Chassis
configuration, the values in the Device and Member fields are identical.
Copyright © 2017, Juniper Networks, Inc.
305
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 32: show virtual-chassis device-topology Output Fields (continued)
Field Name
Field Description
Status
Status of the device:
•
Prsnt—Device is currently connected to the Virtual Chassis.
•
NotPrsnt—Device is not currently connected to the Virtual Chassis.
System ID
Unique identifier derived from the device’s media access control (MAC) address. The
System ID is included in each Virtual Chassis Control Protocol (VCCP) packet to identify
the packet owner to all members of the Virtual Chassis.
Neighbor List
Member/Device/Interface
Member IDs, Device IDs, and Virtual Chassis port interfaces (in the format vcp-slot/pic/port)
to which this device is connected.
Sample Output
show virtual-chassis device-topology all-members
{master:member0-re0}
user@host> show virtual-chassis device-topology all-members
member0:
-------------------------------------------------------------------------Neighbor List
Member Device Status
System ID
Member Device Interface
0
0
Prsnt
b0c6.9abf.6800
1
1
vcp-5/0/0
1
1
Prsnt
001d.b510.0800
0
0
vcp-1/3/0
member1:
-------------------------------------------------------------------------Neighbor List
Member Device Status
System ID
Member Device Interface
0
0
Prsnt
b0c6.9abf.6800
1
1
vcp-5/0/0
1
1
Prsnt
001d.b510.0800
0
0
vcp-1/3/0
show virtual-chassis device-topology local
{master:member0-re0}
user@host> show virtual-chassis device-topology local
Member
0
1
Device
0
1
Status
Prsnt
Prsnt
System ID
b0c6.9abf.6800
001d.b510.0800
Neighbor List
Member Device Interface
1
1
vcp-5/0/0
0
0
vcp-1/3/0
show virtual-chassis device-topology member 1
{master:member0-re0}
user@host> show virtual-chassis device-topology member 1
member1:
-------------------------------------------------------------------------Neighbor List
Member Device Status
System ID
Member Device Interface
306
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
0
1
Copyright © 2017, Juniper Networks, Inc.
0
1
Prsnt
Prsnt
b0c6.9abf.6800
001d.b510.0800
1
0
1
0
vcp-5/0/0
vcp-1/3/0
307
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show virtual-chassis heartbeat (MX Series Virtual Chassis)
Syntax
Release Information
Description
Options
show virtual-chassis heartbeat
<(brief | detail)>
<(all-members | local | member member-id)>
Command introduced in Junos OS Release 14.1.
Display the state of one or both member routers in an MX Series Virtual Chassis
configuration when an IP-based heartbeat packet connection is configured. You can
issue the show virtual-chassis heartbeat command from the console of either member
router in the Virtual Chassis.
none—Display the heartbeat state of both member routers in an MX Series Virtual Chassis.
brief | detail—(Optional) Display the specified level of output. Using the brief option is
equivalent to issuing the command with no options (the default). The detail option
provides more output than the brief option.
all-members—(Optional) Display the heartbeat state of both member routers in an MX
Series Virtual Chassis. This is the default behavior if no options are specified.
local—(Optional) Display the heartbeat state of the member router from which you are
issuing the command.
member member-id—(Optional) Display the heartbeat state of the specified member
router. Replace member-id with the value 0 or 1.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
308
view
•
Verifying and Managing the Virtual Chassis Heartbeat Connection on page 190
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
show virtual-chassis heartbeat on page 310
show virtual-chassis heartbeat detail on page 310
Table 33 on page 309 lists the output fields for the show virtual-chassis heartbeat command.
Output fields are listed in the approximate order in which they appear.
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 33: show virtual-chassis heartbeat Output Fields
Field Name
Field Description
Level of Output
membern
Member ID of the Virtual Chassis member router for which output is displayed.
All levels
Local
IP address of the local member router that forms the heartbeat connection.
All levels
Remote
IP address of the remote member router that forms the heartbeat connection.
All levels
State
State of the heartbeat connection:
All levels
•
Alive—Master Routing Engine in the specified member router is connected
and has received a heartbeat response message.
•
Connected—Master Routing Engine in the specified member router is
connected and awaiting a heartbeat response message.
•
Conn-Pending—Master Routing Engine in the specified member router is
connecting to the other member router.
•
Detected—Master Routing Engine in the specified member router has
successfully exchanged a heartbeat connection message with the other
member router when an adjacency disruption or split occurs in the Virtual
Chassis. The Detected state persists until the heartbeat connection is reset,
or until the Virtual Chassis forms again and a master router (protocol master)
and backup router (protocol backup) are elected.
•
Idle—Heartbeat connection is enabled but not yet connected.
•
Inactive—Heartbeat connection is not active. To activate the connection, you
must configure the heartbeat address and, optionally, the heartbeat timeout
value.
Time
Date and time, in the format yyyy-mm-dd hh:mm:ss, of the last connection state
change. If you have cleared or never collected timestamps, this field displays
Never and the time interval displays 0 (zero).
All levels
Heartbeat
Statistics
Detailed statistics for the heartbeat connection:
detail
•
Heartbeats sent—Number of heartbeat request messages sent.
•
Heartbeats received—Number of heartbeat response messages received.
•
Heartbeats lost/missed—Calculated difference between Heartbeats sent
value and Heartbeats received value.
•
Last time sent—Date and time, in the format yyyy-mm-dd hh:mm:ss, and time
since, in the format (hh:mm:ss ago), the last heartbeat request message was
sent. If you have cleared or never collected timestamps, this field displays
Never and the time interval displays 0 (zero).
•
Last time received—Date and time, in the format yyyy-mm-dd hh:mm:ss, and
time since, in the format (hh:mm:ss ago), the last heartbeat request response
message was received. If you have cleared or never collected timestamps,
this field displays Never and the time interval displays 0 (zero).
•
Maximum latency—Maximum number of seconds that elapse on the local
member router between transmission of a heartbeat request message and
receipt of a heartbeat response message.
•
Minimum latency—Minimum number of seconds that elapse on the local
member router between transmission of a heartbeat request message and
receipt of a heartbeat response message.
Copyright © 2017, Juniper Networks, Inc.
309
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Sample Output
show virtual-chassis heartbeat
{master:member0-re0}
user@host> show virtual-chassis heartbeat
member0:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.2.210
10.4.2.100
Alive
2014-01-14 14:46:52 PDT
member1:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.2.100
10.4.2.210
Alive
2014-01-14 14:46:53 PDT
show virtual-chassis heartbeat detail
{master:member0-re0}
user@host> show virtual-chassis heartbeat detail
member0:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.2.210
10.4.2.100
Alive
2014-01-14 14:46:52 PDT
Heartbeat statistics
Heartbeats sent: 8812
Heartbeats received: 8806
Heartbeats lost/missed: 6
Last time sent: 2014-01-14 14:28:00 PST (00:00:01 ago)
Last time received: 2014-01-14 14:28:00 PST (00:00:01 ago)
Maximum latency (secs): 1
Minimum latency (secs): 0
member1:
-------------------------------------------------------------------------Local
Remote
State
Time
10.4.2.100
10.4.2.210
Alive
2014-01-14 14:46:53 PDT
Heartbeat statistics
Heartbeats sent: 8812
Heartbeats received: 8806
Heartbeats lost/missed: 6
Last time sent: 2014-01-14 14:28:00 PST (00:00:01 ago)
Maximum latency (secs): 1
Minimum latency (secs): 0
310
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
show virtual-chassis protocol adjacency (MX Series Virtual Chassis)
Syntax
Release Information
show virtual-chassis protocol adjacency
<(brief | detail | extensive)>
<(all-members | local | member member-id)>
<system-id>
Command introduced in Junos OS Release 11.2.
Description
Display the entries (neighbors) in the Virtual Chassis Control Protocol (VCCP) adjacency
database for an MX Series Virtual Chassis configuration. You can issue the show
virtual-chassis protocol adjacency command from the console of either member router
in the Virtual Chassis.
Options
brief | detail | extensive—(Optional) Display the specified level of output. Using the brief
option is equivalent to issuing the command with no options (the default). The detail
option provides more output than the brief option. The extensive option provides
complete output and is most useful for customer support personnel.
all-members—(Optional) Display the VCCP adjacency database for both member routers
in a Virtual Chassis. This is the default behavior if no options are specified.
local—(Optional) Display the VCCP adjacency database for the member router on which
you are issuing the command.
member member-id—(Optional) Display the VCCP adjacency database for the specified
member router. Replace member-id with the value 0 or 1.
system-id—(Optional) Display the VCCP adjacency database for the device with the
specified system ID.
Required Privilege
Level
Related
Documentation
view
•
Viewing Information in the Virtual Chassis Control Protocol Adjacency Database on
page 186
List of Sample Output
show virtual-chassis protocol adjacency all-members brief on page 313
show virtual-chassis protocol adjacency member 0 detail on page 314
show virtual-chassis protocol adjacency member 0 detail 001d.b510.0800 on page 314
show virtual-chassis protocol adjacency local extensive on page 314
Output Fields
Table 34 on page 312 lists the output fields for the show virtual-chassis protocol adjacency
command. Output fields are listed in the approximate order in which they appear.
Copyright © 2017, Juniper Networks, Inc.
311
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 34: show virtual-chassis protocol adjacency Output Fields
Field Name
Field Description
Level of Output
membern
Member ID of the Virtual Chassis member router for which output is displayed.
All levels
Interface
Name of the Virtual Chassis port interface, in the format
vcp-slot/pic/port.logical-unit-number.
brief
System
System ID of the device associated with the Virtual Chassis port interface. The
System ID is derived from the device’s media access control (MAC) address.
brief
State
State of the adjacency:
All levels
•
Up—The adjacency is up.
•
Down—The adjacency is down.
Hold (secs)
Remaining hold time of the adjacency, in seconds.
brief
system-id
System ID of the device associated with the Virtual Chassis port interface. The
System ID is derived from the device’s media access control (MAC) address.
detail, extensive
interface-name
Name of the Virtual Chassis port interface, in the format
vcp-slot/pic/port.logical-unit-number.
detail, extensive
Expires in
Number of seconds until the adjacency expires.
detail, extensive
Priority
Priority to become the designated intermediate system.
detail, extensive
Up/Down
transitions
Count of adjacency status changes from Up to Down or from Down to Up.
detail, extensive
Last transition
Time of the last Up/Down transition.
detail, extensive
312
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 34: show virtual-chassis protocol adjacency Output Fields (continued)
Field Name
Field Description
Level of Output
Transition log
List of recent adjacency transitions, including:
extensive
•
When—Date and time at which a VCCP adjacency transition occurred.
•
State—Current state of the VCCP adjacency:
•
•
Up—Adjacency is up and operational.
•
Down—Adjacency is down and not available.
•
Rejected—Adjacency has been rejected.
Event—Type of transition that occurred:
•
Seenself—Possible routing loop has been detected.
•
Interface down—Virtual Chassis port interface has gone down and is no
longer available.
•
•
Error—Adjacency error.
Down reason—Reason that a VCCP adjacency is down:
•
3-Way Handshake Failed—Connection establishment failed.
•
Address Mismatch—Address mismatch caused link failure.
•
Aged Out—Link expired.
•
ISO Area Mismatch—VCCP area mismatch caused link failure.
•
Bad Hello—Unacceptable hello message caused link failure.
•
BFD Session Down—Bidirectional failure detection caused link failure.
•
Interface Disabled—Virtual Chassis port interface is disabled.
•
Interface Down—Virtual Chassis port interface is unavailable.
•
Interface Level Disabled—VCCP level is disabled.
•
Level Changed—VCCP level has changed on the adjacency.
•
Level Mismatch—Levels on adjacency are not compatible.
•
MPLS LSP Down—Label-switched path (LSP) is unavailable.
•
MT Topology Changed—VCCP topology has changed.
•
MT Topology Mismatch—VCCP topology is mismatched.
•
Remote System ID Changed—Adjacency peer system ID changed.
•
Protocol Shutdown—VCCP is disabled.
•
CLI Command—Adjacency brought down by user.
•
Unknown—Unknown.
Sample Output
show virtual-chassis protocol adjacency all-members brief
{master:member0-re0}
user@host> show virtual-chassis protocol adjacency all-members brief
member0:
-------------------------------------------------------------------------Interface
System
State
Hold (secs)
vcp-5/0/0.32768
001d.b510.0800 Up
57
member1:
--------------------------------------------------------------------------
Copyright © 2017, Juniper Networks, Inc.
313
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Interface
vcp-1/3/0.32768
System
State
b0c6.9abf.6800 Up
Hold (secs)
58
show virtual-chassis protocol adjacency member 0 detail
{master:member0-re0}
user@host> show virtual-chassis protocol adjacency member 0 detail
member0:
-------------------------------------------------------------------------001d.b510.0800
interface-name: vcp-5/0/0.32768, State: Up, Expires in 57 secs
Priority: 0, Up/Down transitions: 1, Last transition: 18:50:41 ago
show virtual-chassis protocol adjacency member 0 detail 001d.b510.0800
{master:member0-re0}
user@host> show virtual-chassis protocol adjacency member 0 detail 001d.b510.0800
member0:
-------------------------------------------------------------------------001d.b510.0800
interface-name: vcp-5/0/0.32768, State: Up, Expires in 58 secs
Priority: 0, Up/Down transitions: 1, Last transition: 18:52:08 ago
show virtual-chassis protocol adjacency local extensive
{master:member0-re0}
user@host> show virtual-chassis protocol adjacency local extensive
001d.b510.0800
interface-name: vcp-5/0/0.32768, State: Up, Expires in 59 secs
Priority: 0, Up/Down transitions: 1, Last transition: 18:52:40 ago
Transition log:
When
State
Event
Down reason
Mon Sep 20 17:26:44
Up
Seenself
314
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
show virtual-chassis protocol database (MX Series Virtual Chassis)
Syntax
Release Information
Description
Options
show virtual-chassis protocol database
<(brief | detail | extensive)>
<(all-members | local | member member-id)>
<system-id>
Command introduced in Junos OS Release 11.2.
Display the entries in the Virtual Chassis Control Protocol (VCCP) link-state database
for an MX Series Virtual Chassis configuration. The VCCP link-state database contains
information about protocol data unit (PDU) packets. You can issue the show
virtual-chassis protocol database command from the console of either member router
in the Virtual Chassis.
brief | detail | extensive—(Optional) Display the specified level of output. Using the brief
option is equivalent to issuing the command with no options (the default). The detail
option provides more output than the brief option. The extensive option provides
complete output and is most useful for customer support personnel.
all-members—(Optional) Display the VCCP link-state database for both member routers
in a Virtual Chassis. This is the default behavior if no options are specified.
local—(Optional) Display the VCCP link-state database for the member router on which
you are issuing the command.
member member-id—(Optional) Display the VCCP link-state database for the specified
member router. Replace member-id with the value 0 or 1.
system-id—(Optional) Display the VCCP link-state database for the neighbor with the
specified system ID.
Required Privilege
Level
Related
Documentation
view
•
Viewing Information in the Virtual Chassis Control Protocol Link-State Database on
page 187
List of Sample Output
show virtual-chassis protocol database all-members brief on page 317
show virtual-chassis protocol database member 0 detail on page 318
show virtual-chassis protocol database member 0 b0c6.9abf.6800 detail on page 318
show virtual-chassis protocol database member 0 extensive on page 318
Output Fields
Table 35 on page 316 lists the output fields for the show virtual-chassis protocol database
command. Output fields are listed in the approximate order in which they appear.
Copyright © 2017, Juniper Networks, Inc.
315
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 35: show virtual-chassis protocol database Output Fields
Field Name
Field Description
Level of Output
membern
Member ID of the Virtual Chassis member router for which output is displayed.
All levels
LSP ID
Link-state PDU (LSP) identifier.
All levels
Sequence
Sequence number of the link-state PDU.
All levels
Checksum
Checksum value of the link-state PDU.
All levels
Lifetime
Remaining lifetime of the link-state PDU, in seconds.
All levels
number LSPs
Total number of link-state PDUs in the specified link-state database.
none, brief
Neighbor, Neighbor
Info
Media access control (MAC) address of the neighbor on the advertising system.
detail, extensive
Interface
Name of the Virtual Chassis port interface, in the format
vcp-slot/pic/port.logical-unit-number.
detail, extensive
Metric
Metric value of the prefix or neighbor.
detail, extensive
Header
Link-state PDU (LSP) packet header:
extensive
Packet
•
LSP ID—LSP identifier in the header.
•
Length—Header length, in bytes.
•
Allocated length—Length available for the header, in bytes.
•
Remaining lifetime—Remaining lifetime of the link-state PDU, in seconds.
•
Interface—The interface from which the LSP is received.
•
Estimated free bytes—Estimated number of available bytes in the LSP.
•
Actual free bytes—Actual number of available bytes in the LSP.
•
Aging timer expires in—Remaining lifetime of the LSP, in seconds.
Link-state PDU (LSP) packet:
extensive
•
LSP ID—Identifier for the link-state packet.
•
Length—Packet length, in bytes.
•
Lifetime—Remaining lifetime, in seconds.
•
Checksum—Checksum of the link-state PDU.
•
Sequence—Sequence number of the link-state PDU. This number increments
whenever the link-state PDU is updated.
•
Fixed length—Set length for the packet, in bytes.
•
Version—Protocol version.
•
Sysid length—Length of the system ID, in bytes. The value 0 represents 6
bytes.
316
•
Packet type—Protocol data unit (PDU) type of the LSP.
•
SW version—Junos OS Release number.
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 35: show virtual-chassis protocol database Output Fields (continued)
Field Name
Field Description
Level of Output
TLVs
Link-state PDU (LSP) type, length, and value (TLV):
extensive
•
Member ID—Identifier configured for the Virtual Chassis member router.
•
VC ID—Identifier assigned to the Virtual Chassis member router.
•
Flags—Internal flags that keep track of the member state for the purpose of
mastership election in the Virtual Chassis.
•
Priority—Priority value associated with the role assigned to a member router
in the preprovisioned Virtual Chassis configuration. For example, the priority
value for the routing-engine role is 129. The priority value is used for mastership
election in the Virtual Chassis.
•
System ID—System ID of the device associated with the Virtual Chassis port
interface. The System ID is derived from the device’s media access control
(MAC) address.
•
Device ID—Identifier for the device; usually the same as the Member ID.
•
Neighbor Info—System ID, Virtual Chassis port interface, and metric value for
VCCP neighbor.
•
Topology Info—System ID of the VCCP neighbor.
•
IRI Addr Info—Internal routing interface (IRI) IP address, which is reserved for
internal communication.
•
Master Info—System ID of the master router in the Virtual Chassis.
•
Backup Info—System ID of the backup router in the Virtual Chassis.
•
Stable State Info—Internal state information used for mastership election in
the Virtual Chassis.
•
Member Info—System ID, Member ID, and role of each member router in the
Virtual Chassis.
•
Provision Info—Member ID and chassis serial number specified for each
member router in the preprovisioned configuration for an MX Series Virtual
Chassis.
•
Unknown TLV—Type and length of TLVs with unsupported content received
on this device.
number queued
Number of link-state PDUs queued on the specified Virtual Chassis port interface.
extensive
Sample Output
show virtual-chassis protocol database all-members brief
{master:member1-re0}
user@host> show virtual-chassis protocol database all-members brief
member0:
-------------------------------------------------------------------------LSP ID
Sequence Checksum Lifetime
001d.b510.0800.00-00
0x9eb
0xb8f1
115
b0c6.9abf.6800.00-00
0x9ee
0x8f35
116
2 LSPs
member1:
-------------------------------------------------------------------------LSP ID
Sequence Checksum Lifetime
001d.b510.0800.00-00
0x9eb
0xb8f1
117
Copyright © 2017, Juniper Networks, Inc.
317
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
b0c6.9abf.6800.00-00
2 LSPs
0x9ee
0x8f35
114
show virtual-chassis protocol database member 0 detail
{master:member1-re0}
user@host> show virtual-chassis protocol database member 0 detail
member0:
-------------------------------------------------------------------------001d.b510.0800.00-00 Sequence: 0x9f5, Checksum: 0x5b2b, Lifetime: 116 secs
Neighbor: b0c6.9abf.6800.00 Interface: vcp-1/3/0.32768 Metric:
15
b0c6.9abf.6800.00-00 Sequence: 0x9f8, Checksum: 0x326e, Lifetime: 117 secs
Neighbor: 001d.b510.0800.00 Interface: vcp-5/0/0.32768 Metric:
15
show virtual-chassis protocol database member 0 b0c6.9abf.6800 detail
{master:member1-re0}
user@host> show virtual-chassis protocol database member 0 b0c6.9abf.6800 detail
member0:
-------------------------------------------------------------------------b0c6.9abf.6800.00-00 Sequence: 0xa06, Checksum: 0x925b, Lifetime: 117 secs
Neighbor: 001d.b510.0800.00 Interface: vcp-5/0/0.32768 Metric:
15
show virtual-chassis protocol database member 0 extensive
{master:member1-re0}
user@host> show virtual-chassis protocol database member 0 extensive
member0:
-------------------------------------------------------------------------001d.b510.0800.00-00 Sequence: 0xa09, Checksum: 0xa696, Lifetime: 116 secs
Neighbor: b0c6.9abf.6800.00 Interface: vcp-1/3/0.32768 Metric:
15
Header: LSP ID: 001d.b510.0800.00-00, Length: 804 bytes
Allocated length: 804 bytes,
Remaining lifetime: 116 secs, Interface: 64
Estimated free bytes: 0, Actual free bytes: 0
Aging timer expires in: 116 secs
Packet: LSP ID: 001d.b510.0800.00-00, Length: 804 bytes, Lifetime : 118 secs
Checksum: 0xa696, Sequence: 0xa09,
Fixed length: 27 bytes, Version: 1, Sysid length: 0 bytes
Packet type: 18, SW version: 11.1
TLVs:
Node Info: Member ID: 1, VC ID: 5a6a.e747.8511, Flags: 3, Priority: 129
System ID: 001d.b510.0800, Device ID: 1
Unknown TLV, Type: 0, Length: 0
...
Unknown TLV, Type: 0, Length: 0
Unknown TLV, Type: 1, Length: 1
Neighbor Info: b0c6.9abf.6800.00, Interface: vcp-1/3/0.32768, Metric: 15
Topology Info: System ID: 001d.b510.0800,
Topology Info: System ID: b0c6.9abf.6800,
IRI Addr Info: IP Address: 128.0.0.1,
318
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
IRI Addr Info: IP Address: 128.0.0.4,
IRI Addr Info: IP Address: 128.0.0.5,
IRI Addr Info: IP Address: 128.0.0.6,
IRI Addr Info: IP Address: 128.0.0.17,
Master Info: System ID: 001d.b510.0800
Backup Info: System ID: b0c6.9abf.6800
Stable State Info: Master ID: 001d.b510.0800, Backup ID: b0c6.9abf.6800
Member Info: System ID: b0c6.9abf.6800, Member ID: 0 Member role: Backup
System ID: b0c6.9abf.6800, Device ID: 0
Member Info: System ID: 001d.b510.0800, Member ID: 1 Member role: Master
System ID: 001d.b510.0800, Device ID: 1
Provision Info: Member ID: 1 Serial Number: JN10C78D1AFC,
Provision Info: Member ID: 0 Serial Number: JN115FDADAFB,
Unknown TLV, Type: 24, Length: 1
Unknown TLV, Type: 28, Length: 56
1 queued :
Send PSN on vcp-5/0/0.32768 for 00:00:01
b0c6.9abf.6800.00-00 Sequence: 0xa0d, Checksum: 0x82d2, Lifetime: 118 secs
Neighbor: 001d.b510.0800.00 Interface: vcp-5/0/0.32768 Metric:
15
Header: LSP ID: b0c6.9abf.6800.00-00, Length: 808 bytes
Allocated length: 1400 bytes,
Remaining lifetime: 118 secs, Interface: 0
Estimated free bytes: 546, Actual free bytes: 592
Aging timer expires in: 118 secs
Packet: LSP ID: b0c6.9abf.6800.00-00, Length: 808 bytes, Lifetime : 118 secs
Checksum: 0x82d2, Sequence: 0xa0d,
Fixed length: 27 bytes, Version: 1, Sysid length: 0 bytes
Packet type: 18, SW version: 11.1
TLVs:
Node Info: Member ID: 0, VC ID: 5a6a.e747.8511, Flags: 5, Priority: 129
System ID: b0c6.9abf.6800, Device ID: 0
Unknown TLV, Type: 0, Length: 0
...
Unknown TLV, Type: 0, Length: 0
Unknown TLV, Type: 1, Length: 1
Neighbor Info: 001d.b510.0800.00, Interface: vcp-5/0/0.32768, Metric: 15
Topology Info: System ID: 001d.b510.0800,
Topology Info: System ID: b0c6.9abf.6800,
IRI Addr Info: IP Address: 128.0.0.1,
IRI Addr Info: IP Address: 128.0.0.4,
IRI Addr Info: IP Address: 128.0.0.5,
IRI Addr Info: IP Address: 128.0.0.6,
IRI Addr Info: IP Address: 128.0.0.17,
IRI Addr Info: IP Address: 128.0.0.21,
Master Info: System ID: 001d.b510.0800
Backup Info: System ID: b0c6.9abf.6800
Stable State Info: Master ID: 001d.b510.0800, Backup ID: b0c6.9abf.6800
Member Info: System ID: b0c6.9abf.6800, Member ID: 0 Member role: Backup
System ID: b0c6.9abf.6800, Device ID: 0
Member Info: System ID: 001d.b510.0800, Member ID: 1 Member role: Master
System ID: 001d.b510.0800, Device ID: 1
Provision Info: Member ID: 1 Serial Number: JN10C78D1AFC,
Provision Info: Member ID: 0 Serial Number: JN115FDADAFB,
Unknown TLV, Type: 24, Length: 1
Unknown TLV, Type: 28, Length: 56
Copyright © 2017, Juniper Networks, Inc.
319
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
1 queued :
Retransmit on vcp-5/0/0.32768 for 00:00:01
320
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
show virtual-chassis protocol interface (MX Series Virtual Chassis)
Syntax
Release Information
Description
Options
show virtual-chassis protocol interface
<(brief | detail)>
<interface-name>
<(all-members | local | member member-id)>
Command introduced in Junos OS Release 11.2.
Display Virtual Chassis Control Protocol (VCCP) information about Virtual Chassis port
interfaces in an MX Series Virtual Chassis. You can issue the show virtual-chassis protocol
interface command from the console of either member router in the Virtual Chassis.
brief | detail—(Optional) Display the specified level of output. Using the brief option is
equivalent to issuing the command with no options (the default). The detail option
provides more output than the brief option.
all-members—(Optional) Display VCCP information about Virtual Chassis port interfaces
for both member routers in a Virtual Chassis. This is the default behavior if no options
are specified.
interface-name—(Optional) Display VCCP information about Virtual Chassis port interfaces
for the specified Virtual Chassis port, in the format
vcp-slot/pic/port.logical-unit-number.
local—(Optional) Display VCCP information about Virtual Chassis port interfaces for the
member router on which you are issuing the command.
member member-id—(Optional) Display VCCP information about Virtual Chassis port
interfaces for the specified member router. Replace member-id with the value 0 or
1.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
view
•
Viewing Information About Virtual Chassis Port Interfaces in the Virtual Chassis Control
Protocol Database on page 188
show virtual-chassis protocol interface brief all-members on page 322
show virtual-chassis protocol interface detail all-members on page 323
show virtual-chassis protocol interface detail local on page 323
Table 36 on page 322 lists the output fields for the show virtual-chassis protocol interface
command. Output fields are listed in the approximate order in which they appear.
Copyright © 2017, Juniper Networks, Inc.
321
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 36: show virtual-chassis protocol interface Output Fields
Field Name
Field Description
Level of Output
membern
Member ID of the Virtual Chassis member router for which output is displayed.
All levels
Interface
Name of the Virtual Chassis port interface, in the format
vcp-slot/pic/port.logical-unit-number.
brief
State
State of the Virtual Chassis port interface:
brief
•
Up—The interface is up.
•
Down—The interface is down.
Metric
Metric value for this Virtual Chassis port interface.
All levels
vcp-slot/
pic/port.
logical-unit-number
Name of the Virtual Chassis port interface.
detail
Index
Interface index number assigned by the Junos OS software.
detail
State
Internal implementation information.
detail
LSP interval
Interval, in milliseconds, between link-state protocol data units (PDUs) sent
from the interface.
detail
type Hello padding
Type of hello padding:
detail
•
Adaptive—On point-to-point connections, the hello packets are padded from
the initial detection of a new neighbor until the neighbor verifies the adjacency
as Up in the adjacency state type, length, and value (TLV). If the neighbor
does not support the adjacency state TLV, then padding continues. On LAN
connections, padding starts from the initial detection of a new neighbor until
there is at least one active adjacency on the interface.
•
Loose—(Default) The hello packet is padded from the initial detection of a
new neighbor until the adjacency transitions to the Up state.
•
Strict—Padding is performed on all interface types and for all adjacency
states, and is continuous.
Adjacencies
Number of adjacencies established on this Virtual Chassis port interface.
detail
Hello(s)
Hello interval for the Virtual Chassis port interface.
detail
Hold(s)
Hold time for the Virtual Chassis port interface.
detail
Sample Output
show virtual-chassis protocol interface brief all-members
{master:member1-re0}
user@host> show virtual-chassis protocol interface brief all-members
322
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
member0:
-------------------------------------------------------------------------IS-IS interface database:
Interface
State
Metric
vcp-5/0/0.32768
Up
15
member1:
-------------------------------------------------------------------------IS-IS interface database:
Interface
State
Metric
vcp-1/3/0.32768
Up
15
show virtual-chassis protocol interface detail all-members
{master:member1-re0}
user@host> show virtual-chassis protocol interface detail all-members
member0:
-------------------------------------------------------------------------IS-IS interface database:
vcp-5/0/0.32768
Index: 64, State: 0x46
LSP interval: 100 ms, Loose Hello padding
Adjacencies Metric Hello (s) Hold (s)n
1
15
3
60
member1:
-------------------------------------------------------------------------IS-IS interface database:
vcp-1/3/0.32768
Index: 64, State: 0x86
LSP interval: 100 ms, Loose Hello padding
Adjacencies Metric Hello (s) Hold (s)n
1
15
3
60
15
3
60
show virtual-chassis protocol interface detail local
{master:member1-re0}
user@host> show virtual-chassis protocol interface detail local
IS-IS interface database:
vcp-1/3/0.32768
Index: 64, State: 0x46
LSP interval: 100 ms, Loose Hello padding
Adjacencies Metric Hello (s) Hold (s)n
Copyright © 2017, Juniper Networks, Inc.
1
323
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show virtual-chassis protocol route (MX Series Virtual Chassis)
Syntax
Release Information
show virtual-chassis protocol route
<destination-id>
<(all-members | local | member member-id)>
Command introduced in Junos OS Release 11.2.
Description
Display the Virtual Chassis Control Protocol (VCCP) unicast and multicast routing tables
for an MX Series Virtual Chassis. You can issue the show virtual-chassis protocol route
command from the console of either member router in the Virtual Chassis.
Options
all-members—(Optional) Display the VCCP unicast and multicast routing tables for both
member routers in a Virtual Chassis configuration. This is the default behavior if no
options are specified.
destination-id—(Optional) Display the VCCP unicast and multicast routing tables to the
destination with the specified system ID.
local—(Optional) Display the VCCP unicast and multicast routing tables for the member
router on which you are issuing the command.
member member-id—(Optional) Display the VCCP unicast and multicast routing tables
for the specified member router. Replace member-id with the value 0 or 1.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
view
•
Viewing Virtual Chassis Control Protocol Routing Tables on page 188
show virtual-chassis protocol route all-members on page 325
show virtual-chassis protocol route member 0 001d.b510.0800 (For Specific Member
ID and Destination ID) on page 326
Table 37 on page 324 lists the output fields for the show virtual-chassis protocol route
command. Output fields are listed in the approximate order in which they appear.
Table 37: show virtual-chassis protocol route Output Fields
Field Name
Field Description
membern
Member ID of the Virtual Chassis member router for which output is displayed.
Dev
System ID of the device (member router) that stores the VCCP routing tables. The System
ID is derived from the router’s media access control (MAC) address.
ucast routing table
VCCP unicast routing table.
324
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 37: show virtual-chassis protocol route Output Fields (continued)
Field Name
Field Description
mcast routing table
VCCP multicast routing table.
Current version
Version of the shortest-path-first (SPF) algorithm that generated the VCCP unicast or
multicast routing table.
System ID
System ID of the device, derived from the device’s MAC address.
Version
Version of the SPF algorithm that generated this route in the VCCP unicast or multicast
routing table.
Metric
Metric value required to reach this device.
Interface
Name of the Virtual Chassis port interface (in the format
vcp-slot/pic/port.logical-unit-number) that interconnects the devices.
Via
MAC address of the next-hop device, if applicable.
Sample Output
show virtual-chassis protocol route all-members
{master:member1-re0}
user@host> show virtual-chassis protocol route all-members
member0:
-------------------------------------------------------------------------Dev b0c6.9abf.6800 ucast routing table
Current version: 17
---------------System ID
Version
Metric Interface
Via
001d.b510.0800
17
15 vcp-5/0/0.32768 001d.b510.0800
b0c6.9abf.6800
17
0
Dev b0c6.9abf.6800 mcast routing table
Current version: 17
---------------System ID
Version
Metric Interface
Via
001d.b510.0800
17
b0c6.9abf.6800
17
vcp-5/0/0.32768
member1:
-------------------------------------------------------------------------Dev 001d.b510.0800 ucast routing table
Current version: 17
---------------System ID
Version
Metric Interface
Via
001d.b510.0800
17
0
b0c6.9abf.6800
17
15 vcp-1/3/0.32768 b0c6.9abf.6800
Dev 001d.b510.0800 mcast routing table
Current version: 17
---------------System ID
Version
Metric Interface
Via
001d.b510.0800
17
vcp-1/3/0.32768
b0c6.9abf.6800
17
Copyright © 2017, Juniper Networks, Inc.
325
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show virtual-chassis protocol route member 0 001d.b510.0800 (For Specific Member ID and Destination ID)
{master:member1-re0}
user@host> show virtual-chassis protocol route member 0 001d.b510.0800
member0:
-------------------------------------------------------------------------Dev b0c6.9abf.6800 ucast routing table
Current version: 17
---------------System ID
Version
Metric Interface
Via
001d.b510.0800
17
15 vcp-5/0/0.32768 001d.b510.0800
b0c6.9abf.6800
17
0
Dev b0c6.9abf.6800 mcast routing table
Current version: 17
---------------System ID
Version
Metric Interface
Via
001d.b510.0800
17
b0c6.9abf.6800
17
vcp-5/0/0.32768
326
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
show virtual-chassis protocol statistics (MX Series Virtual Chassis)
Syntax
Release Information
Description
Options
show virtual-chassis protocol statistics
<interface-name>
<(all-members | local | member member-id)>
Command introduced in Junos OS Release 11.2.
Display Virtual Chassis Control Protocol (VCCP) statistics for one or both member routers,
or for a specified Virtual Chassis port interface, in an MX Series Virtual Chassis. You can
issue the show virtual-chassis protocol statistics command from the console of either
member router in the Virtual Chassis.
all-members—(Optional) Display VCCP statistics for both member routers in a Virtual
Chassis configuration. This is the default behavior if no options are specified.
interface-name—(Optional) Display VCCP statistics for the specified Virtual Chassis port
interface, in the format vcp-slot/pic/port.logical-unit-number.
local—(Optional) Display VCCP statistics for the member router on which you are issuing
the command.
member member-id—(Optional) Display VCCP statistics for the specified member router.
Replace member-id with the value 0 or 1.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
view
•
Viewing Virtual Chassis Control Protocol Statistics for Member Devices and Virtual
Chassis Ports on page 189
show virtual-chassis protocol statistics all-members on page 328
show virtual-chassis protocol statistics vcp-1/3/0.32768 member 1 (For Specific
Virtual Chassis Port Interface and Member ID) on page 329
Table 38 on page 327 lists the output fields for the show virtual-chassis protocol statistics
command. Output fields are listed in the approximate order in which they appear.
Table 38: show virtual-chassis protocol statistics Output Fields
Field Name
Field Description
membern
Member ID of the Virtual Chassis member router for which output is displayed.
PDU type
Type of protocol data unit (PDU).
Received
Number of PDUs received since VCCP started or since the statistics were set to zero.
Copyright © 2017, Juniper Networks, Inc.
327
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
Table 38: show virtual-chassis protocol statistics Output Fields (continued)
Field Name
Field Description
Processed
Number of PDUs received minus the number of PDUs dropped.
Drops
Number of PDUs dropped.
Sent
Number of PDUs transmitted since VCCP started or since the statistics were set to zero.
Rexmit
Number of PDUs retransmitted since VCCP started or since the statistics were set to zero.
Total packets
received
Total number of PDUs received since VCCP started or since the statistics were set to zero.
Sent
Total number of PDUs transmitted since VCCP started or since the statistics were set to
zero.
LSP queue length
Number of link-state PDUs waiting in the queue to be processed.
Drops
Number of link-state PDUs dropped.
SPF runs
Number of shortest-path-first (SPF) calculations performed.
Fragments rebuilt
Number of link-state PDU fragments computed by the local system.
LSP regenerations
Number of regenerated link-state PDUs. A link-state PDU is regenerated when the PDU
nears the end of its lifetime and has not changed.
Purges initiated
Number of purges initiated by the software. A purge is initiated when the software
determines that it must remove a link-state PDU from the network.
Sample Output
show virtual-chassis protocol statistics all-members
{master:member1-re0}
user@host> show virtual-chassis protocol statistics all-members
member0:
-------------------------------------------------------------------------IS-IS statistics for b0c6.9abf.6800:
PDU type
Received
Processed
LSP
2937
2937
HELLO
2913
2913
CSNP
1
1
PSNP
2916
2916
Unknown
0
0
Totals
8767
8767
Drops
0
0
0
0
0
0
Sent
2934
2922
1
2925
0
8782
Rexmit
0
0
0
0
0
0
Total packets received: 8767 Sent: 8782
LSP queue length: 0 Drops: 0
SPF runs: 17
328
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Fragments rebuilt: 2955
LSP regenerations: 14
Purges initiated: 0
member1:
-------------------------------------------------------------------------IS-IS statistics for 001d.b510.0800:
PDU type
Received
Processed
LSP
2934
2934
HELLO
2922
2922
CSNP
1
1
PSNP
2925
2925
Unknown
0
0
Totals
8782
8782
Drops
0
0
0
0
0
0
Sent
2937
2914
1
2916
0
8768
Rexmit
0
0
0
0
0
0
Total packets received: 8782 Sent: 8768
LSP queue length: 0 Drops: 0
SPF runs: 17
Fragments rebuilt: 2953
LSP regenerations: 11
Purges initiated: 0
show virtual-chassis protocol statistics vcp-1/3/0.32768 member 1 (For Specific Virtual Chassis Port Interface
and Member ID)
{master:member1-re0}
user@host> show virtual-chassis protocol statistics vcp-1/3/0.32768 member 1
member1:
-------------------------------------------------------------------------vcp-1/3/0.32768
IS-IS statistics for 001d.b510.0800:
PDU type
Received
Processed
LSP
3013
3013
HELLO
3001
3001
CSNP
1
1
PSNP
3003
3003
Unknown
0
0
Totals
9018
9018
Drops
0
0
0
0
0
0
Sent
3016
2993
1
2994
0
9004
Rexmit
0
0
0
0
0
0
Total packets received: 9018 Sent: 9004
Copyright © 2017, Juniper Networks, Inc.
329
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show virtual-chassis status (MX Series Virtual Chassis)
Syntax
Release Information
Description
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
show virtual-chassis status
Command introduced in Junos OS Release 11.2.
Display information about the status of both member routers in an MX Series Virtual
Chassis configuration. You can issue the show virtual-chassis status command from the
console of either member router in the Virtual Chassis.
view
•
Verifying the Status of Virtual Chassis Member Routers or Switches on page 183
•
Verifying and Managing the Virtual Chassis Heartbeat Connection on page 190
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in the Same Subnet on page 196
•
Example: Determining Member Health Using an MX Series Virtual Chassis Heartbeat
Connection with Member Routers in Different Subnets on page 207
show virtual-chassis status on page 331
show virtual-chassis status (Mismatch Status) on page 331
Table 39 on page 330 lists the output fields for the show virtual-chassis status command.
Output fields are listed in the approximate order in which they appear.
Table 39: show virtual-chassis status Output Fields
Field Name
Field Description
Virtual Chassis ID
Assigned ID that applies to the entire Virtual Chassis configuration.
Member ID
Member ID assigned in the preprovisioned Virtual Chassis configuration, and the Flexible PIC
Concentrator (FPC) slot range, including offset, for each member router in the Virtual Chassis.
Status
State of the member router:
•
Heartbt—Router has used heartbeat packet connection to maintain mastership roles during
an adjacency disruption or split in the Virtual Chassis configuration.
•
Mismatch—Virtual Chassis not formed due to a mismatch in the slot count value of the
member routers. In a Virtual Chassis with an MX2020 member router and either an MX960
or MX2010 member router, a mismatch status occurs if you do not set the slot count value
of the MX960 router or MX2010 router to 20 to match the slot count of the MX2020 router.
330
•
Prsnt—Router is currently connected to the Virtual Chassis.
•
NotPrsnt—Router is not currently connected to the Virtual Chassis.
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 39: show virtual-chassis status Output Fields (continued)
Field Name
Field Description
Serial No
Serial number of the member router.
Model
Model number of the member router.
Mastership priority
Metric used by the Virtual Chassis software for the mastership election algorithm.
This value is assigned by the software and is not configurable in the current release.
Role
Role of the member router in the Virtual Chassis: Master or Backup.
The asterisk ( * ) following the Role denotes the router on which the show virtual-chassis
status command was issued.
Neighbor List
ID Interface
Member IDs and Virtual Chassis port interfaces (in the format vcp-slot/pic/port) to which this
member router is connected.
Sample Output
show virtual-chassis status
{master:member1-re0}
user@host> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 5a6a.e747.8511
Member ID
Status
0 (FPC
0- 11) Prsnt
1 (FPC 12- 23) Prsnt
Serial No
Model
JN115FDADAFB mx480
JN10C78D1AFC mx240
Mastership
priority
Role
129 Backup
129 Master*
Neighbor List
ID Interface
1 vcp-5/0/0
0 vcp-1/3/0
show virtual-chassis status (Mismatch Status)
{master:member1-re0}
user@host> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 4b43.17d9.1dcf
Mastership
Neighbor
List
Member ID
Status
Serial No
Model
priority
Role
ID Interface
0 (FPC
0- 19) Mismatch JN11CA3F9AFK mx2010
1 (FPC 20- 39) Prsnt
JN122D1DAAFJ mx2020
129 Master*
Copyright © 2017, Juniper Networks, Inc.
331
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show virtual-chassis vc-port (MX Series Virtual Chassis)
Syntax
Release Information
Description
Options
show virtual-chassis vc-port
<(all-members | local | member member-id)>
Command introduced in Junos OS Release 11.2.
Display the operational status of the Virtual Chassis ports for both member routers or
for a specified member router in an MX Series Virtual Chassis configuration. You can issue
the show virtual-chassis vc-port command from the console of either member router in
the Virtual Chassis.
all-members—(Optional) Display the operational status of the Virtual Chassis ports for
both member routers in a Virtual Chassis configuration.
local—(Optional) Display the operational status of the Virtual Chassis ports on the
member router on which you are issuing the command. This is the default behavior
if no options are specified.
member member-id—(Optional) Display the operational status of the Virtual Chassis
ports on the specified member router. Replace member-id with the value 0 or 1.
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields
view
•
Verifying the Operation of Virtual Chassis Ports on page 183
•
Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers Using
a Virtual Chassis on page 58
•
Example: Configuring Interchassis Redundancy for MX Series 3D Universal Edge Routers
Using a Virtual Chassis on page 75
show virtual-chassis vc-port all-members on page 333
show virtual-chassis vc-port local on page 333
show virtual-chassis vc-port member 0 on page 334
show virtual-chassis vc-port (Packet Forwarding Engine is not Ready) on page 334
Table 40 on page 332 lists the output fields for the show virtual-chassis vc-port command.
Output fields are listed in the approximate order in which they appear.
Table 40: show virtual-chassis vc-port Output Fields
Field Name
Field Description
membern
Member ID of the Virtual Chassis member router for which output is displayed.
Interface or
Slot/PIC/Port
Location, in the format slot/pic/port, of the Virtual Chassis ports configured on the member router.
332
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: Operational Commands
Table 40: show virtual-chassis vc-port Output Fields (continued)
Field Name
Field Description
Type
Type of Virtual Chassis port. Configured indicates that the Virtual Chassis port is properly configured.
Trunk ID
Trunk ID value assigned to a link aggregation group (LAG) formed by the Virtual Chassis. A positive
number indicates that a trunk exists. The value -1 indicates that a trunk is not present.
Status
State of the Virtual Chassis port interface:
•
Up—The port interface is up.
•
Up (Resync-not-set)—The port interface is up but the packet forwarding engine is not ready for
forwarding.
•
Down—The port interface is down.
•
Absent—The port interface is absent.
Speed (mbps)
Speed, in megabits per second, of the Virtual Chassis port interface.
Neighbor
ID Interface
Member IDs and Virtual Chassis port interfaces ( in vcp-slot/pic/port format) that are connected to this
member router.
Sample Output
show virtual-chassis vc-port all-members
{master:member1-re0}
user@host> show virtual-chassis vc-port all-members
member0:
-------------------------------------------------------------------------Interface
Type
Trunk Status
Speed
Neighbor
or
ID
(mbps)
ID Interface
Slot/PIC/Port
5/0/0
Configured
-1
Up
10000
1
vcp-1/3/0
member1:
-------------------------------------------------------------------------Interface
Type
Trunk Status
Speed
Neighbor
or
ID
(mbps)
ID Interface
Slot/PIC/Port
1/3/0
Configured
-1
Up
10000
0
vcp-5/0/0
show virtual-chassis vc-port local
{master:member1-re0}
user@host> show virtual-chassis vc-port local
Interface
or
Slot/PIC/Port
1/3/0
Copyright © 2017, Juniper Networks, Inc.
Type
Configured
Trunk
ID
-1
Status
Speed
(mbps)
Neighbor
ID Interface
Up
10000
0
vcp-5/0/0
333
Interchassis Redundancy Using Virtual Chassis Feature Guide for MX Series Routers
show virtual-chassis vc-port member 0
{master:member1-re0}
user@host> show virtual-chassis vc-port member 0
member0:
-------------------------------------------------------------------------Interface
Type
Trunk Status
Speed
Neighbor
or
ID
(mbps)
ID Interface
Slot/PIC/Port
5/0/0
Configured
-1
Up
10000
1
vcp-1/3/0
show virtual-chassis vc-port (Packet Forwarding Engine is not Ready)
{master:member1-re0}
user@host> show virtual-chassis vc-port
member1:
------------------------------------------------------------------------—
Interface
Type
Trunk Status
Speed
Neighbor
or
ID
(mbps)
ID Interface
Slot/PIC/Port
3/0/2
Configured -1
Up
10000
1
vcp-1/1/4
3/0/3
Configured -1
Up (Resync-not-set)
10000
1
vcp-1/1/0
334
Copyright © 2017, Juniper Networks, Inc.