Phoenix Inverter VE.Direct 250VA

Phoenix Inverter VE.Direct 250VA
Phoenix Inverters
250VA – 800VA
www.victronenergy.com
230V and 120V, 50Hz or 60Hz
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Phoenix 12/375 VE.Direct
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 - 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Phoenix 12/375 VE.Direct
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko
UK
AU/NZ
Screw terminals
No special tools needed for installation
IEC-320
(male plug included)
Nema 5-15R
Phoenix Inverter
12 Volt
24 Volt
48 Volt
Cont. power at 25°C (1)
Cont. power at 25°C / 40°C
Peak power
12/250
24/250
48/250
250VA
12/375
24/375
48/375
375VA
12/500
24/500
48/500
500VA
12/800
24/800
48/800
800VA
200 / 175W
300 / 260W
400 / 350W
650 / 560W
400W
700W
900W
1500W
Output AC voltage / frequency (adjustable)
230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%
Input voltage range
DC low shut down (adjustable)
Dynamic (load dependent) DC low shut down
(fully configurable)
DC low restart and alarm (adjustable)
9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V
9,3 / 18,6 / 37,2V
Dynamic cut-off, see
https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
10,9 / 21,8 / 43,6V
Battery charged detect (adjustable)
Max. efficiency
Zero-load power
Default zero-load power in ECO mode
(default retry interval: 2,5 s, adjustable)
14,0 / 28,0 / 56,0V
87 / 88 / 88%
89 / 89 / 90%
90 / 90 / 91%
90 / 90 / 91%
4,2 / 5,2 / 7,9W
5,6 / 6,1 / 8,5W
6 / 6,5 / 9W
6,5 / 7 / 9,5W
0,8 / 1,3 / 2,5W
0,9 / 1,4 / 2,6W
1 / 1,5 / 3,0
1 / 1,5 / 3,0
ECO mode stop and start power setting
Adjustable
Protection (2)
Operating temperature range
a-f
-40 to +65°C (fan assisted cooling)
Humidity (non-condensing)
Derate 1,25% per °C above 40°C
max 95%
ENCLOSURE
Material & Colour
Steel chassis and plastic cover (blue Ral 5012)
Battery-connection
Maximum cable cross-section
Screw terminals
10 mm² / AWG8
10 mm² / AWG8
10 mm² / AWG8
25/10/10mm² /
AWG4/8/8
230V: Schuko (CEE 7/4), IEC-320 (male plug included)
UK (BS 1363), AU/NZ (AS/NZS 3112)
120V: Nema 5-15R
IP 21
Standard AC outlets
Protection category
Weight
2,4kg / 5,3lbs
3,0kg / 6,6lbs
3,9kg / 8.5lbs
Dimensions (hxwxd, mm)
(hxwxd, inch)
86 x 165 x 26o
3.4 x 6.5 x 10.2
86 x 165 x 260
3.4 x 6.5 x 10.2
86 x 172 x 275
3,4 x 6,8 x 10,8
5,5kg / 12lbs
105 x 216 x 305
4.1 x 8.5 x 12.1
(12V model:
105 x 230 x 325)
ACCESSORIES
Remote on-off
Yes
Automatic transfer switch
Filax
STANDARDS
Safety
EMC
EN-IEC 60335-1 / EN-IEC 62109-1
EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3
Automotive Directive
ECE R10-4
1) Nonlinear load, crest factor 3:1
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) DC ripple too high
Battery Alarm
BMV Battery Monitor
An excessively high or low battery voltage is indicated
by an audible and visual alarm, and a relay for remote
signalling.
The BMV Battery Monitor features an advanced microprocessor control system combined
with high resolution measuring systems for battery voltage and charge/discharge current.
Besides this, the software includes complex calculation algorithms to exactly determine
the state of charge of the battery. The BMV selectively displays battery voltage, current,
consumed Ah or time to go. The monitor also stores a host of data regarding performance
and use of the battery.
VE.Direct Bluetooth Smart dongle
(must be ordered separately)
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising