The Dual Door Controller (DDC) is an access control field device for MDI’s Integrated
Digital Controllers. The DDC functions as a door interface for the Network Local
Controller (NLC)/Network Communications Board (COMM), integrating card readers
and associated door hardware into a single package. The unit is configurable for two
doors with entry readers or for one door with entry and exit readers.
The DDC memory stores
20,000 card records. All
access control decisions for
its two readers are made by
the DDC using this
database. Cards that have
not been used for a preset
number of days are
removed from the DDC
database and replaced with
more active cards.
When a card’s record is not
found in the DDC database,
the card data is passed to
the NLC for the access
control decision. If
communication between the
DDC and NLC/COMM is
disrupted, the DDC
continues to make access
decisions for its 20,000 cardholders. Up to 512 events are stored at the DDC and passed
to the NLC/COMM when communications is restored.
Security Suite Hardware
Features
• Supports 2 doors with Entry Readers or
1 door with Entry/Exit Readers
• Each reader port has connections for
power, data, 2 LEDs and Buzzer
• Supported readers include Magstripe,
Wiegand, Barcode, Proximity,
Biometrics, and SmartCard
• Supports industry standard and custom
card formats
• Stores 20,000 cardholder database
• Access decisions are made at the DDC
using local database, even during loss
of communication with NLC/COMM
• Stores 500 events
• Access decisions are made at NLC
when card not found in DDC database
• Inactive card records are removed from
DDC database and replaced with active
cards
• 4 Supervised inputs: 2 door monitor and
2 alarm inputs
• 8 Non-supervised inputs: 2 Request-toexit (REX), 2 tamper and 4 Auxiliary
inputs
• 6 Form-C output relays (3 per door):
door lock, alarm and spare
• Accepts 6.0 - 16.0 Vdc power source
• Downloadable FLASH MEMORY
eliminates the need to change EPROMs
for applications programming and
system upgrades RS-485 bus remote
installation up to 4,000 feet (1300m)
from NLC/COMM
The DDC features 2 reader ports, flexible input and output configurations, FLASH
memory for application programs (firmware) and SDRAM for cardholder database and
event storage. The interface between the DDC and NLC/COMM utilizes industry
standard RS-485 communications protocol that allows the DDC to be located up to
4,000 feet from the NLC/COMM.
The DDC is configured with a diagnostic port which allows field service and other
technical personnel to view activity, perform diagnostics analysis, and make some
configuration changes.
“Your Secure Choice
for the Future”
MDI Security Systems
9725 Datapoint Drive, Suite 200
San Antonio, Texas 78229
Tel: 210-477-5400
Fax: 210-477-5401
Toll-free: 866-435-7634
www.mdisecure.com
Dual Door Controller
Technical Specifications
(DDC)
Security Suite Hardware
Electrical
RS-485 port
to NLC/COMM
Power 6-16 Volts DC
Current Draw 120mA maximum
Dimensions
5 vdc or input DC
Ground
Width 7.0 in. (178 mm)
Length 5.0 in. (127 mm)
Height 1.0 in. (26 mm)
Data 0, data
Data 1, clock
5 vdc or input DC
Ground
Reader A
Reader B
LED 1
LED 2
Buzzer
Environment
Temperature 32ºF-120ºF, (0ºC-50ºC)
Humidity 10%-95% (non-condensing)
Door Contacts
REX
Door Lock Relay
Door Alarm Relay
Memory
Read Only 64 Kbytes Flash Memory
Random 512 Kbytes SDRAM for
-Card Data: 20,000 cards
-Event Storage: 512 events
on loss of communications
with NLC/COMM
LED 1
LED 2
Buzzer
Door A
Door B
Tamper Switch
General Purpose
Inputs
Data 0, data
Data 1, clock
Door Contacts
REX
Door Lock Relay
Door Alarm Relay
Tamper Switch
Dual Door
Controller
( DDC )
General Purpose
Inputs
Spare Relay
Spare Relay
RS-232 Port for
Diagnostics
Communications
Protocol
Distance
Media Type
Diagnostics Port
RS-485
4,000 feet
Twisted Pair (Belden 9841 cable)
RS-232
Readers
Quantity 2
Configurations Two doors (Entry/Entry) or
Single Door (Entry/Exit)
Types Magstripe, Wiegand, Proximity,
Barcode, Biometric, and SmartCard
Card Formats Standard and Custom
LED Support Single or dual color per reader
Buzzer Support 1 per reader
Supplied Power +5 Vdc @ 100mA total or
direct DDC input voltage
Inputs
Supervised 2 Door position
2 Alarm or general purpose
Non-Supervised 2 Tamper
2 Request to Exit
4 Alarm or general purpose
Outputs
Relay Outputs 2 – Door Lock
2 – Alarm (ON - door forced or
door propped timeout, PULSING (door propped warning)
2 – Spare
Keypad Support
Wiegand Keypad Keypads with Wiegand output are
integrated on reader data lines
ACT-430 I2C port supports two
ACT-430 Access Control Terminals
PIN Support 4, 5 or 6 digits
Tel: 210-477-5400
Fax: 210-477-5401
Design and specifications subject
to change without notice.
Toll-free: 866-435-7634
www.mdisecure.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising