460ETCBMS-N34
BACnet MS/TP to Allen-Bradley PLC
FEATURES
 Supports Connection
for up to 5 AllenBradley PLCs
 BACnet MS/TP
Supports Device,
Binary I/O, Analog I/O
and Character String
Value Object Types
 Map data from up to
300 user defined tags
or register blocks in
your PLC
 Map BACnet MS/TP
data directly to tags or
registers in your AllenBradley PLC
 Effortless Browser
Based Configuration,
no programming
software is required
 Simple data
translation allows you
to manipulate data as
it passes between
protocols
Get Your BACnet MS/TP System Connected Directly to the
Data Table of your Allen-Bradley PLC
The 460ETCBMS moves data between a BACnet MS/TP system and an
Allen-Bradley PLC.
With the 460ETCBMS you are making a direct connection between BACnet
MS/TP Master data and user defined Tags or Registers in the data table of
your Allen-Bradley PLC. There is no polling from the PLC or Ethernet/IP
scan lists to arrange. This is a direct connection between your device data
and the data table of your PLC.
How Does the Data Move In and Out of the PLC?
You allocate two areas of tags or register blocks in your Allen-Bradley PLC.
One area is a user defined set of write only tags or register blocks accepting
data from your BACnet MS/TP Master. The other area is full of read only
tags or register blocks to send data to your BACnet MS/TP Master. You
directly map BACnet MS/TP analog and binary data into read and write
locations in the data table of your Allen-Bradley PLC.
It’s really that simple.
Why Use Real Time Automation as a Gateway Supplier?
The 460ETCBMS provides an option to access a BACnet MS/TP data or tie an Allen-Bradley
PLC in your BMS system without having to upgrade your PLC or get an expensive in rack
solution. While there are certainly a number of other companies offering stand alone gateways,
there is no one who provides the level of support and service that you receive from RTA.
When you call, a live person answers the phone. When you talk with sales, you will get honest
answers and recommendations even if that means recommending someone else's solution.
When you get support, it is from an engineer who had a hand in the product’s development, and
doesn't require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller
company because that means you mean a lot more to us.
Try the RTA difference today and give us a call at 1-800-249-1612 or check out more
information on us and our other solutions at www.rtaautomation.com.
A Word from our Founder
“It’s likely that your business isn’t industrial networking and it shouldn’t be. You make products, design systems, or
manage some process. Whatever it is that you make, monitor or install the process inevitably creates data. If
you’re a control engineer and your plant has been around for a few years your line is probably littered with devices
that send out all kinds of data over many different protocols. If you’re an automation device developer you probably
have customers that need to move your data into some other network. Either way, you’ve got a device conversion
problem. You have devices that generate ASCII , Modbus RTU, Modbus TCP, BACnet, Profinet, Profibus, Ethernet
TCP/IP , Ethernet/IP, DeviceNet or some other completely proprietary data and now you’re the person that has to
move that data to some other network! I feel your pain… and rather than just my sympathy, I have a solution for
you. You see, while your business may not be moving data around a factory floor mine is. In fact, it’s all that we
have done for over twenty years now. Our 460 series of Device Converters is the culmination of those twenty
years. You can now move all of your data, where you want, when you want and how you want. Try us on your next
project, I guarantee you wont regret it.”
John Rinaldi
Specifications
www.rtaautomation.com
BACnet MS/TP DEVICE FEATURES
BACnet/ MS/TP Operation Modes
BACnet MS/TP Master Responder
Supported Object Types
Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes
Maximum Connections
Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding-B, Dynamic Object Binding-B
1
Analog Objects Supported
1200 Input and 1200 Output
Binary Objects Supported
1600 Input and 1600 Output
Character String Objects Supported
50 Input and 50 Output
ETHERNET/IP TAG CLIENT FEATURES
PLC Support
ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC’s and PLC5E’s
Maximum Number of PLCs Supported
5
Maximum Number of Input Scan Lines per PLC
150
Maximum Number of Output Scan Lines per PLC
150
Net ENI Support
Supported
Supported Data Types
ControlLogix / CompactLogix / FlexLogix: Bit, 32 Bit Array, SINT, INT, REAL, STRING, DINT,
MicroLogix / SLC / PLC5E: 16 Bit Array, INT, REAL, STRING
INCLUDED WITH GATEWAY
120 volt AC wall wart power supply
Manual
6’ power cable with flying leads
5 year hardware warranty
IPSetup software — automatically locates RTA gateway on the network
Unlimited firmware feature upgrades for life
CAT5 crossover cable for direct connection to PC during programming
Complete, unlimited access to our industry leading support staff
ELECTRICAL/ENVIRONMENTAL
DIMENSIONS
DC Input Voltage
8 VDC @ 230 mA to 28 VDC @ 80 mA
Maximum Baud Rate
115K baud
Operating Temperature
-40 C to 85 C
RoHS-Compliant, UL, CUL, CE Approvals, Class I Div 2
Certification
ENCLOSURE / HARDWARE
Size
4.2” x 3.25” x 1”
Weight
5 oz.
Enclosure Type
Anodized aluminum
Mounting
Din rail or panel mount
LEDs
Ethernet link/data LED, Ethernet speed LED, power LED, &
2 general purpose LEDS on side
GATWAY FEATURES & FUNCTIONS
Gateway Security
You can configure up to 9 different users access to
diagnostic and configuration screens.
Alarming
Set <, <=, >=, >, ==, !=, and change-of-state rules on
any data moving through the gateway. If alarm rule is
triggered an email notification can be sent.
Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur
in the gateway.
Status and
Counters
Protocol specific status, counters and error messages
are accessible within the gateways diagnostics page.
They can also be delivered to a connected device.
Diagnostic Logging
Page
Allows users to see and log start up sequences, protocol specific messages & error messages.
NOT EXACTLY WHAT YOU WERE LOOKING FOR?
Real Time Automation offers a full line of gateway products. If this isn’t the one
you were looking for give us a call at1-800-249-1612 or check out a listing at
www.rtaautomation.com/products. We also offer custom gateways to help customers dealing with unique needs or proprietary protocols.
CATALOG #
DESCRIPTION
460ETCBMS-N34
BACnet MS/TP System to Allen-Bradley PLC Gateway
Allen-Bradley, ControlLogix, CompactLogix, PLC-5 are registered trademarks of Rockwell Automation, Inc.
Real Time Automation, Inc. - www.rtaautomation.com - 1-800-249-1612