Replacing the Power Supply in the Cisco AS5300

Series and Cisco AS5400 Series Routers

Product Numbers: AS53-AC-PWR=, AS53-DC-PWR=, AS535-AC-PWR=,

AS535-DC-PWR=, AS535-AC-RPS=, AS535-DC-RPS=, AS54-DC-RPS=,

AS54-AC-RPS=

This document describes how to replace the internal AC or DC power supply in the Cisco AS5300 series and Cisco AS5400 series universal gateways, and includes the following sections:

Safety Recommendations, page 1

Related Documentation, page 4

Required Tools and Equipment, page 5

Removing and Installing the Cisco AS5300 Power Supply, page 5

Removing and Installing the Cisco AS5350 Power Supply, page 21

Removing and Installing the Cisco AS5400 Power Supply, page 34

Obtaining Documentation, page 53

Obtaining Technical Assistance, page 55

Safety Recommendations

Follow these guidelines to ensure general safety:

• Keep the chassis area clear and dust-free during and after installation.

Put the removed chassis cover in a safe place.

Keep tools away from walk areas where you or others could fall over them.

Do not wear loose clothing that could get caught in the chassis. Fasten your tie or scarf and roll up your sleeves.

Wear safety glasses when working under any conditions that might be hazardous to your eyes.

Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.

Corporate Headquarters:

Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA

Copyright © 2001 - 2003. Cisco Systems, Inc. All rights reserved.

Safety Recommendations

Safety Warnings

Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each safety warning.

Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Waarschuwing

Varoitus

Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information

(Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.

Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information

-kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).

Attention

Warnung

Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d’avertissements figurant dans cette publication, consultez le document Regulatory Compliance

and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.

Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer

Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur

Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen

Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information

(Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.

Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory

Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.

2

Safety Warnings

78-4519-04

Safety Recommendations

Advarsel

Aviso

¡Advertencia!

Varning!

Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet

Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.

Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e

Disposições Reguladoras) que acompanha este dispositivo.

Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and

Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.

Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada.

Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information

(Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.

Safety with Electricity

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance

and Safety Information document that accompanied this device.

Warning Read the installation instructions before you connect the system to its power source. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

Warning Only trained and qualified personnel should be allowed to install or replace this equipment. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

78-4519-04

Warning Before working on a chassis or working near power supplies, unplug the power cord on AC units; disconnect the power at the circuit breaker on DC units. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Safety with Electricity

3

Related Documentation

Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Follow these guidelines when working on equipment powered by electricity:

• Locate the emergency power-OFF switch in the room in which you are working. Then, if an electrical accident occurs, you can quickly shut the power OFF.

Disconnect all power before doing the following:

– Installing or removing a chassis

– Working near power supplies

Do not work alone if potentially hazardous conditions exist.

Never assume that power is disconnected from a circuit. Always check.

Look carefully for possible hazards in your work area, such as moist floors, ungrounded power extension cables, and missing safety grounds.

• If an electrical accident occurs, proceed as follows:

– Use caution; do not become a victim yourself.

Turn OFF power to the system.

If possible, send another person to get medical aid. Otherwise, determine the condition of the victim and then call for help.

– Determine if the person needs rescue breathing or external cardiac compressions; then take appropriate action.

Preventing Electrostatic Discharge Damage

Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD occurs when electronic printed circuit cards are improperly handled, and can result in complete or intermittent failures.

Always follow ESD prevention procedures when removing and replacing cards. Ensure that the chassis is electrically connected to earth ground. Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground. To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.

Caution For safety, periodically check the resistance value of the antistatic strap, which should be between 1 and

10 megohms (Mohm).

Related Documentation

This document is to be used with the following documents:

• Cisco AS5300 Chassis Installation Guide

• Cisco AS5350 Universal Gateway Chassis Installation Guide

Preventing Electrostatic Discharge Damage

4 78-4519-04

Required Tools and Equipment

Regulatory Compliance and Safety Information

Installing a Redundant Power Supply in Cisco AS5300 Universal Access Servers

Cisco AS5400 Universal Gateway Chassis Installation Guide

Cisco AS5400 Regulatory Compliance and Safety Information

Required Tools and Equipment

To replace the power supply, you will need:

• AC or DC power supply kit

Medium-size Phillips screwdriver

Small or medium flat-blade screwdriver

ESD-preventive wrist strap

Tie-wraps (optional)

Antistatic bag (optional)

Removing and Installing the Cisco AS5300 Power Supply

The following sections describe how to remove and install the Cisco AS5300 power supply:

Removing the Chassis Cover, page 6

Removing the Old Power Supply, page 8

Installing the New Power Supply, page 14

Replacing the Chassis Cover, page 19

Note For information on removing and installing the redundant power supply for the Cisco AS5300, see the guide, Installing a Redundant Power Supply in Cisco AS5300 Universal Access Servers, that comes with your power supply.

78-4519-04

Required Tools and Equipment

5

Removing and Installing the Cisco AS5300 Power Supply

Removing the Chassis Cover

This section describes how to access the internal components by removing the chassis cover.

Warning Do not touch the power supply when the power cord is connected. For systems with a power switch, line voltages are present within the power supply even when the power switch is off and the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Warning Before working on a chassis or working near power supplies, unplug the power cord on AC units; disconnect the power at the circuit breaker on DC units. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Warning Before opening the chassis, disconnect the telephone-network cables to avoid contact with telephone-network voltages. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

To remove the chassis cover, follow these steps:

Step 1

Step 2

Step 3

Turn the power switch on the access server off and disconnect site power. (Note that the power switch is part of the power supply.)

Remove all interface cables from the rear panel of the chassis.

Place the chassis so that the front panel is facing you.

6

Removing the Chassis Cover

78-4519-04

Removing and Installing the Cisco AS5300 Power Supply

Step 4

Remove the four screws on the chassis cover. (See Figure 1.)

Figure 1 Removing the Chassis Cover Screws

4

78-4519-04

Step 5

Lift the chassis cover upward and pull it away from the tabs on the rear of the chassis. (See Figure 2.)

Figure 2 Removing the Chassis Cover

Chassis cover

Cisco AS5400

SERIES

Front panel

Chassis bottom

Removing the Chassis Cover

7

Removing and Installing the Cisco AS5300 Power Supply

Removing the Old Power Supply

This section describes how to remove the power supply. Note the following safety warnings before you remove the power supply:

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance

and Safety Information document that accompanied this device.

Warning Only trained and qualified personnel should be allowed to install or replace this equipment. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

Warning Read the installation instructions before you connect the system to its power source. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

Warning Before working on a chassis or working near power supplies, unplug the power cord on AC units; disconnect the power at the circuit breaker on DC units. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

To remove the power supply, follow these steps:

Step 1 Place the chassis so that the rear panel is facing you.

Note Although the following illustrations show only the AC power supply, the procedures are the same for the DC power supply.

8

Removing the Old Power Supply

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5300 Power Supply

Step 2 Remove the three mounting screws that secure the power supply to the chassis and set them aside. (See

Figure 3.)

Figure 3 Removing the Power Supply Mounting Screws

Mounting screws

Step 3

Step 4

Power supply

Turn the chassis so that the front panel is facing you.

Lift the air separator out of the chassis. (See Figure 4.)

Figure 4 Removing the Air Separator

Air separator

Front panel

Removing the Old Power Supply

9

Removing and Installing the Cisco AS5300 Power Supply

Step 5

Pull the fan closest to the power supply away from the sheet metal tabs. (See Figure 5.)

Figure 5 Pulling the Fan Away from the Tabs

Fan

Chassis bottom

Fan tabs

Step 6

Front panel

Lift the fan from the chassis and set the fan on top of the power supply. (See Figure 6.)

Figure 6 Removing the Fan

Fan

Chassis bottom

10

Removing the Old Power Supply

Front panel

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5300 Power Supply

Step 7

Disconnect the fan cable. (See Figure 7.)

Caution

Do not attempt to remove the fan cables without first depressing the tab as shown in Figure 7. You can

damage the fan cables by applying stress if the connector is not removed properly.

Figure 7 Disconnecting the Fan Cable

Depress tab and pull outward

Fan

Fan connector

Power supply

Step 8

Location of the 3 remaining fan connectors

Remove the next fan and disconnect its cable. You can disconnect the cables for the two remaining fans without removing the fans.

Note There are three different lengths of 2 wire +/- 12 VDC power cables. The two shortest cables go

to the two fans that were removed in Step 6 through Step 8. The two longer cables go to the two

remaining fans. The single medium-length cable goes to the power connector on the backplane.

If you use an incorrect cable to connect a fan or the backplane, then you are unable to make one of the other connections.

Removing the Old Power Supply

11

Removing and Installing the Cisco AS5300 Power Supply

Step 9 Disconnect the power connectors from the backplane. First disconnect the 2-pin 12V connector and

then disconnect the 4-jack harness. (See Figure 8.)

Figure 8 Disconnecting the Power Connectors from the Backplane

Depress tab and pull

12V connector

Power connector

Backplane

Power supply

12

Removing the Old Power Supply

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5300 Power Supply

Step 10 Slide the power supply toward the front panel to disengage the power supply from the chassis hook.

Remove the power supply from the chassis. (See Figure 9.)

Figure 9 Removing the Power Supply from the Chassis

Chassis hook

Power supply hook

Power supply

Front panel

Chassis bottom

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance

and Safety Information document that accompanied this device.

Removing the Old Power Supply

13

Removing and Installing the Cisco AS5300 Power Supply

Installing the New Power Supply

To install the new power supply, follow these steps:

Step 1 Place the power supply in the chassis and slide it toward the rear panel. You will feel the hooks engage.

(See Figure 10.)

Figure 10 Inserting the Power Supply in the Chassis

Chassis hook

Power supply hook

Power supply

Chassis bottom

Front panel

14

Installing the New Power Supply

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5300 Power Supply

Step 2

First reconnect the 4-jack harness and then reconnect the 2-pin 12V connector, as shown in Figure 11.

Note For clarity, the illustration does not show the fans in place.

Caution Observe the proper keying of the DC output connector to the back panel connector. Never force the connector, because you could damage your Cisco AS5300.

Figure 11 Reconnecting the Power Cables to the Backplane

12V connector

Power supply

Power connector

Front panel

Backplane

Installing the New Power Supply

15

Removing and Installing the Cisco AS5300 Power Supply

Step 3

Route the fan cables exactly as shown in Figure 12.

Note The two longest cables are connected to the two installed fans on the right. The connectors to these two fans fit into the space between the second and third fans.

Figure 12 Routing the Fan Cables

Sheet metal tabs

Front panel

Base tabs

Step 4 Insert the second fan, making sure that the fan cable feeds to your left. Position the cables to the two installed fans so that they fit under the first and second fans. Press the fan into place between the four

sheet metal tabs. (See Figure 12.)

16

Installing the New Power Supply

78-4519-04

Step 5

Reconnect the two 2-pin fan cables. (See Figure 13.)

Figure 13 Reconnecting the Fan Cables

Removing and Installing the Cisco AS5300 Power Supply

Fan connector

Front panel

Fan

78-4519-04

Installing the New Power Supply

17

Removing and Installing the Cisco AS5300 Power Supply

Step 6 Reinstall the remaining fan. Make sure that you orient the fan so that the cables feed to the right

(toward the second fan). Then route the cable completely under the fan before you reconnect it. This

takes up the extra length of fan cable and keeps it out of the way. (See Figure 14.)

Figure 14 Correct Fan Cable Routing

Step 7 Replace the air separator, holding all cables to the right of the separator as you slip it into the chassis.

(See Figure 15.)

Figure 15 Replacing the Air Separator

Air separator

Front panel

18

Installing the New Power Supply

78-4519-04

Removing and Installing the Cisco AS5300 Power Supply

Step 8 Turn the chassis so that you face the rear panel and reinstall the three mounting screws. (See

Figure 16.)

Figure 16 Replacing the Power Supply Mounting Screws

Mounting screws

Step 9

Power supply

If you installed a different type of power supply (AC or DC) than was originally installed in the access server, place one of the power ratings labels that came in the plastic bag with the documentation directly over the power ratings information on the rear panel. For example, if the original chassis came with an AC power supply and you replaced it with a DC power supply, place the DC power ratings label over the ratings stamped on the rear panel of the chassis. This ensures that the correct power ratings

information appears on the rear panel. (See Figure 17 and Figure 18.)

Figure 17Power Ratings Label for DC Power Supply

INPUT 48 – 60V === 9 – 7A 300W

Figure 18Power Ratings Label for AC Power Supply

INPUT 100 – 240V~ 50/60Hz 2 – 5A

Step 10

Replace the chassis cover as described in the next section, “Replacing the Chassis Cover.”

Replacing the Chassis Cover

To replace the chassis cover, follow these steps:

Step 1 Place the chassis bottom so that the front panel is facing you.

78-4519-04

Replacing the Chassis Cover

19

Removing and Installing the Cisco AS5300 Power Supply

Step 2 Hold the chassis cover over the chassis bottom, and align each of the cover tabs with the chassis tabs at

the top rear of the chassis. (See Figure 19.)

Figure 19 Replacing the Chassis Cover

Chassis tabs

Cover tabs

Cover

4

Front panel Chassis bottom

Step 3 Lower the front of the chassis cover to close the chassis, and ensure the following:

• The chassis cover tabs fit under the edge of the chassis rear panel so that they are not exposed.

The chassis tabs fit under the chassis cover so that they are not exposed.

The chassis cover side tabs on both sides fit inside the chassis side panels so that they are not exposed.

When the chassis cover is properly assembled, no tabs are visible. (See Figure 20.)

Figure 20 Cisco AS5300 Chassis

Step 4

Step 5

Step 6

Secure the chassis cover with four screws.

Reinstall the chassis on a rack, desktop, or table.

Reinstall all interface cables.

20

Replacing the Chassis Cover

78-4519-04

Removing and Installing the Cisco AS5350 Power Supply

Step 7 Reconnect the AC power cord or rewire the DC power supply.

Warning After wiring the DC power supply, remove the tape from the circuit breaker switch handle and reinstate power by moving the handle of the circuit breaker to the ON position. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety

Information document that accompanied this device.

Step 8 Power on the access server.

The internal power supply fan should power on.

Removing and Installing the Cisco AS5350 Power Supply

The Cisco AS5350 universal gateway supports a single power supply or a redundant power supply. A redundant power supply has two power connections and provides higher reliability and load balancing.

You can use the redundant power supply to:

• Manage your system with alarms and other management features.

Provide higher reliability with a second built-in power supply connected to a second power source.

Balance loads.

Note The redundant power supply on the Cisco AS5350 requires Cisco IOS Release 12.2(2)XB5 or later release.

The following sections describe how to remove and install the Cisco AS5350 power supply:

Removing the Chassis Cover, page 21

Removing the Old Power Supply, page 25

Installing the Power Supply, page 29

Replacing the Chassis Cover, page 31

Removing the Chassis Cover

You must open the universal gateway chassis to gain access to its interior components.

To open the chassis, follow these steps:

Step 1 Turn the power switch on the universal gateway off and disconnect site power.

Note Note that the power switch is part of the power supply.

Note

If you are using a DC-powered unit, refer to Figure 21 or Figure 22 and complete Step a through

Step d.

78-4519-04

Removing and Installing the Cisco AS5350 Power Supply

21

Removing and Installing the Cisco AS5350 Power Supply

Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit.

To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Figure 21 DC Power Supply Connections—Single Power Supply

Power switch To DC source

Source A - NEG Ground

Source A - RTN Source B - RTN

Source B - NEG

DC connector

22

Removing the Chassis Cover

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5350 Power Supply

Figure 22 DC Power Supply Connections—Redundant Power Supply

DC connector

Power switch

A- A+ B- B+

Source A - NEG

Source A - RTN

Ground

Source B - RTN

Source B - NEG

Step 2

Step 3 a.

b.

Loosen the five locking screws for the negative, return, and ground connectors on the DC connectors.

Remove the -48 VDC wires from the DC connector negative connectors (-).

Remove the 48 VDC wires from the DC connector positive connectors (+).

c.

d.

Remove the safety ground (green wires) from the DC connector ground connectors.

Remove all interface cables from the rear panel of the universal gateway.

Place the universal gateway so that the front panel is facing you.

Removing the Chassis Cover

23

Removing and Installing the Cisco AS5350 Power Supply

Step 4

Remove the five screws on the chassis cover. (See Figure 23.)

Figure 23 Removing the Chassis Cover Screws

3

Step 5 Gently pry the cover off with a flat-blade screwdriver. Lift the chassis cover upward, as shown in

Figure 24, and pull it away from the tabs on the rear of the chassis.

Figure 24 Removing the Chassis Cover

Chassis cover

3

Front panel

Chassis bottom

Step 6

Continue with the “Removing the Power Supply” section on page 37.

24

Removing the Chassis Cover

78-4519-04

Removing and Installing the Cisco AS5350 Power Supply

Removing the Old Power Supply

This section describes how to remove the power supply. Note the following safety warnings before you remove the power supply:

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance

and Safety Information document that accompanied this device.

Warning Only trained and qualified personnel should be allowed to install or replace this equipment. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

Warning Read the installation instructions before you connect the system to its power source. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

Warning Before working on a system that has an on/off switch, turn OFF the power and unplug the power cord.

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance

and Safety Information document that accompanied this device.

Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

To remove the power supply, follow this procedure:

Step 1

Step 2

Place the universal gateway so that the rear panel is facing you.

Remove the mounting screw that secures the power supply to the chassis and set it aside. (See Figure 25 or Figure 26.)

Note Although the following illustrations show only the AC power supply, the procedures are the same for the DC power supply.

78-4519-04

Removing the Old Power Supply

25

Removing and Installing the Cisco AS5350 Power Supply

Figure 25 Removing the Power Supply Mounting Screws

Power supply

Mounting screw

Figure 26 Removing the Redundant Power Supply Mounting Screw

Step 3

Step 4

Mounting screw

Turn the universal gateway so that the front panel is facing you.

Lift the air separator out of the chassis. (See Figure 27.)

26

Removing the Old Power Supply

78-4519-04

Figure 27 Removing the Air Separator

Removing and Installing the Cisco AS5350 Power Supply

78-4519-04

Power supply

3

Front panel

Chassis bottom

Note There are two power connectors on the power supply. One connects to the backplane and the

other to the system board. (See Figure 28.)

Figure 28 Power Supply Connectors

Power supply

Backplane connector

System board connector

Step 5 Disconnect both power supply connectors. Disconnect the backplane connector first, followed by the

system board connector. (See Figure 29.)

Removing the Old Power Supply

27

Removing and Installing the Cisco AS5350 Power Supply

Note The system board connector is located on the system board, below and left of the backplane connector.

Figure 29 Disconnecting the Power Connectors from the Backplane

Power supply

3

Front panel

Power connector

Backplane

Chassis bottom

Step 6 Slide the power supply toward the front panel to disengage the power supply from the chassis hooks (See

Figure 30) and remove the power supply from the chassis.

Figure 30 Lifting the Power Supply Out of the Chassis

Power supply

3

Front panel

Chassis bottom

28

Removing the Old Power Supply

78-4519-04

Removing and Installing the Cisco AS5350 Power Supply

Installing the Power Supply

To install the power supply, follow this procedure:

Step 1

Place the power supply as shown in Figure 31, then slide it toward the rear panel. You will feel the

chassis hooks engage with the slots on the bottom of the power supply. The same procedure applies to both the AC and DC power supplies.

Figure 31 Inserting the Power Supply in the Chassis

Power supply

3

Front panel

Chassis bottom

Step 2

Connect the two power connectors to the system board and backplane. (See Figure 28.) Connect the

system board connector first, followed by the backplane connector. (See Figure 32.)

Note The system board connector is located on the system board, below and left of the backplane connector.

78-4519-04

Installing the Power Supply

29

Removing and Installing the Cisco AS5350 Power Supply

Figure 32 Reconnecting the Power Cables to the Backplane

Power supply

3

Front panel

Power connector

Backplane

Chassis bottom

Step 3 Replace the air separator, holding all cables to the right of the separator as you slip it into the chassis.

(See Figure 33.)

Figure 33 Replacing the Air Separator

Power supply

3

Front panel

Chassis bottom

30

Installing the Power Supply

78-4519-04

Removing and Installing the Cisco AS5350 Power Supply

Step 4

Step 5

Reinstall the power supply mounting screw.

Replace the chassis cover using the procedures in the “Replacing the Chassis Cover” section on page 31.

Replacing the Chassis Cover

To replace the chassis cover, follow this procedure:

Step 1

Step 2

Place the chassis bottom so that the front panel is facing you.

Hold the chassis cover over the chassis bottom, and align each of the cover tabs with the chassis tabs at

the top rear of the chassis, as shown in Figure 34.

Figure 34 Replacing the Chassis Cover

Chassis cover

3

Front panel

Chassis bottom

78-4519-04

Step 3

Step 4

Step 5

Lower the front of the top cover to close the chassis, and ensure the following:

• The chassis cover tabs fit under the edge of the chassis rear panel so that they are not exposed.

The chassis tabs fit under the chassis cover so that they are not exposed.

The chassis cover side tabs on both sides fit inside the chassis side panels so that they are not exposed.

When the chassis cover is properly assembled, no tabs are visible.

Secure the chassis cover with five screws.

If you installed a different type of power supply (AC or DC) than was originally installed in the universal gateway, place one of the power ratings labels that came in the plastic bag with the documentation directly over the power ratings information on the rear panel. For example, if the original chassis came with an AC power supply and you replaced it with a DC power supply, place the

DC power ratings label over the ratings stamped on the rear panel of the chassis. This ensures that the

correct power ratings information appears on the rear panel. (See Figure 35 and Figure 36.)

Replacing the Chassis Cover

31

Removing and Installing the Cisco AS5350 Power Supply

Figure 35Power Ratings Label for DC Power Supply

INPUT -48/-60V == 3A 150VA

Figure 36Power Ratings Label for AC Power Supply

INPUT 100 – 240V~ 50/60Hz 2 – 1A

Step 6

Step 7

Step 8

Reinstall the chassis on a rack, desktop, or table.

Reinstall all interface cables.

Reconnect the AC power cords. Or, if you are using a DC-powered unit, refer to Figure 37 and Figure 38,

and complete Step a through Step e.

Warning The illustration shows the DC power supply terminal block. Wire the DC power supply using the appropriate wire terminations at the wiring end, as illustrated. The proper wiring sequence is ground to ground, return to return, and negative to negative. Note that the ground wire should always be connected first and disconnected last. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Figure 37 Connecting DC Power Supply—Single Power Supply

Power switch To DC source

DC connector

Source A - NEG

Source A - RTN

Ground

Source B - RTN

Source B - NEG

Caution Do not overtorque the terminal block contact screws. The recommended torque is 4.5 lb-in. (0.50 N-m).

32

Replacing the Chassis Cover

78-4519-04

Removing and Installing the Cisco AS5350 Power Supply

Figure 38 Connecting DC Power Supply—Redundant Power Supply

DC connector

Power switch

A- A+ B- B+

78-4519-04

Source A - NEG

Source A - RTN

Ground

Source B - RTN

Source B - NEG

Note This product is intended for installation in restricted access areas and is approved for connection using 12 or 14 AWG copper conductors only. The installation must comply with all applicable codes. a.

Strip off a quarter of an inch (1/4 in. [0.625 cm]) of insulation on the safety ground, +48 VDC, and

-48 VDC input wires.

Note For central office installations, it is recommended to use a 6 AWG green ground wire with one end connected to reliable earth. The other end of the wire should be crimped onto the double-hole lug provided in the installation pack. The lug should be secured to the mating holes on the side of the chassis with the two screws included in the accessory pack.

Note If you are installing a redundant power supply, you should attach appropriate sized spade terminals to the stripped ends of the ground and input wires.

b.

c.

d.

e.

Insert the safety ground (green wires) into the DC connector ground connectors and tighten the locking screws. Ensure that no bare wire is exposed.

Insert the 48 VDC Return wires into the DC connector positive connectors (+) and tighten the locking screws. Ensure that no bare wire is exposed.

Insert the -48 VDC wires into the DC connector negative connectors (-) and tighten the locking screws. Ensure that no bare wire is exposed.

Make sure that the power supply wires are secured to cable strain-relief clamps with cable ties.

Replacing the Chassis Cover

33

Removing and Installing the Cisco AS5400 Power Supply

Warning After wiring the DC power supply, remove the tape from the circuit breaker switch handle and reinstate power by moving the handle of the circuit breaker to the ON position. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety

Information document that accompanied this device.

Step 9 Power on the universal gateway.

The internal power supply fan should power on.

Removing and Installing the Cisco AS5400 Power Supply

The Cisco AS5400 universal gateway has a redundant power supply. A redundant power supply has two power cords to provide higher reliability and load balancing. You can use the redundant power supply to:

Manage your system with alarms and other management features.

Provide higher reliability with a second built-in power supply connected to a second power source.

• Balance loads.

The following sections describe how to remove and install the Cisco AS5400 power supply:

Removing the Chassis Cover, page 34

Removing the Power Supply, page 37

Installing the Power Supply, page 43

Replacing the Chassis Cover, page 50

Verifying Status of the Redundant Power Supply, page 52

Configuring the Power Supply Alarm, page 53

Removing the Chassis Cover

You must open the universal gateway chassis to gain access to its interior components.

To remove the chassis cover, follow these steps:

Step 1 Turn the power switch on the universal gateway off and disconnect site power at the power supply.

Note The power switch is part of the power supply.

Step 2

If you are using a DC-powered unit, refer to Figure 39 and complete steps a through d.

34

Removing and Installing the Cisco AS5400 Power Supply

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5400 Power Supply

Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit.

To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Figure 39 DC Power Supply Connections

Mounting screw

Strain-relief clamps

Mounting screw

LEDs

IN OK

DC OK

OTF

Terminal block

On/off switch

LEDs

IN OK

DC OK

OTF

Terminal block

Mounting screw

Strain-relief clamps b.

c.

d.

a.

Loosen the six locking screws for the negative, return, and ground connectors on the DC power supply terminal blocks.

Remove the -48 VDC wires from the terminal block negative connectors (-).

Remove the 48 VDC wires from the terminal block positive connectors (+).

Remove the safety ground (green wires) from the terminal block ground connectors.

Caution Do not connect the 48 VDC wire to the chassis. A single point ground is recommended at the power distribution rack.

Step 3

Step 4

Remove all interface cables from the rear panel of the chassis.

Place the chassis so that the front panel is facing you.

Removing the Chassis Cover

35

Removing and Installing the Cisco AS5400 Power Supply

Step 5

Remove the four screws on the chassis cover. (See Figure 40.)

Figure 40 Removing the Chassis Cover Screws

4

Step 6 Gently pry the cover off with a flat-blade screwdriver. Lift the chassis cover upward, and pull it away

from the tabs on the rear of the chassis. (See Figure 41.)

Figure 41 Removing the Chassis Cover

Chassis cover

Cisco AS5400

SERIES

Front panel

Chassis bottom

Step 7

Continue with the following section, “Removing the Power Supply.”

36

Removing the Chassis Cover

78-4519-04

Removing and Installing the Cisco AS5400 Power Supply

Removing the Power Supply

This section describes how to remove the power supply. Note the following safety warnings before you remove the power supply:

Warning Ultimate disposal of this product should be handled according to all national laws and regulations.

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance

and Safety Information document that accompanied this device.

Warning Only trained and qualified personnel should be allowed to install or replace this equipment. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

Warning Read the installation instructions before you connect the system to its power source. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and

Safety Information document that accompanied this device.

Warning Before working on a system that has an on/off switch, turn OFF the power and unplug the power cord.

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance

and Safety Information document that accompanied this device.

Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

To remove the power supply, follow these steps:

Step 1 Place the chassis so that the rear panel is facing you.

78-4519-04

Removing the Power Supply

37

Removing and Installing the Cisco AS5400 Power Supply

Step 2 Remove the three mounting screws that secure the power supply to the chassis and set them aside. (See

Figure 42.)

Note Although the following illustrations show only the AC power supply, the procedures are the same for the DC power supply.

Figure 42 Removing the Power Supply Mounting Screws

Mounting screws

AC OK

DC OK

OTF

AC OK

DC OK

OTF

Step 3

Step 4

Power supply

Turn the chassis so that the front panel is facing you.

Lift the air separator out of the chassis. (See Figure 43.)

Figure 43 Removing the Air Separator

Air separator

Front panel

38

Removing the Power Supply

78-4519-04

Removing and Installing the Cisco AS5400 Power Supply

Step 5

Pull the fan closest to the power supply away from the sheet metal tabs. (See Figure 44.)

Figure 44 Pulling the Fan Away from the Tabs

78-4519-04

Fan

4

Chassis bottom

Fan tabs

Front panel

Step 6

Lift the fan out of the chassis, and set the fan on top of the power supply. (See Figure 45.)

Figure 45 Removing the Fan

Fan

4

Front panel

Chassis bottom

Removing the Power Supply

39

Removing and Installing the Cisco AS5400 Power Supply

Step 7

Disconnect the fan cable, and set the fan aside. (See Figure 46.)

Caution

Do not attempt to remove the fan cables without first depressing the tab as shown in Figure 46. You can

damage the fan cables by applying stress if the connector is not removed properly.

Figure 46 Disconnecting the Fan Cable

Depress tab and pull outward

Fan

Fan connector

Power supply

Location of the 3 remaining fan connectors

Step 8

Step 9

Remove the next fan and disconnect its cable.

Remove the cables for the two remaining fans. You can disconnect these cables without removing the fans.

Note There are three different lengths of 2 wire, 12 VDC power cables. The two shortest cables go to

the fan that you removed in Step 6. The two longer cables go to the three remaining fans removed

in Step 8 and Step 9. The remaining cable goes to the power connector on the backplane.

These cables are color-coded. If you use an incorrect cable to connect a fan or the backplane, then you are unable to make one of the other connections. To help with reconnecting the cables, write down which colored cable goes to each fan.

40

Removing the Power Supply

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5400 Power Supply

Step 10 Disconnect the power connectors from the backplane by disconnecting the 2-pin 12V connector, and

disconnecting the power connector’s 4-jack harness. (See Figure 47.)

Figure 47 Disconnecting the Power Connectors from the Backplane

Depress tab and pull

12V connector

Backplane

6-pin connector

Power connector

Power supply

Step 11

Disconnect the 6-pin connector from the motherboard. (See Figure 47.)

Removing the Power Supply

41

Removing and Installing the Cisco AS5400 Power Supply

Step 12 Slide the power supply toward the front panel to disengage the power supply hook from the chassis hook,

and remove the power supply from the chassis. (See Figure 48.)

Figure 48 Lifting the Power Supply Out of the Chassis

Power supply

Chassis hook

Power supply slot

4

Front panel

Chassis bottom

42

Removing the Power Supply

78-4519-04

Removing and Installing the Cisco AS5400 Power Supply

Installing the Power Supply

To install the power supply, follow these steps:

Step 1

Place the power supply as shown in Figure 49, and slide it toward the rear panel.

Figure 49 Inserting the Power Supply in the Chassis

Chassis hook

Power supply slot

Power supply

4

Front panel

Chassis bottom

78-4519-04

Installing the Power Supply

43

Removing and Installing the Cisco AS5400 Power Supply

Step 2

Connect the 6-pin connector to the motherboard. (See Figure 50.)

Note For clarity, the illustration does not show the fans in place or the fan cables.

Figure 50 Connecting the 6-Pin Connector to the Motherboard

12V connector

Power supply

6-pin connector

Front panel

Backplane

44

Installing the Power Supply

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5400 Power Supply

Step 3 Reconnect the power connector’s 4-jack harness, and reconnect the 2-pin 12V connector. (See

Figure 51.)

Figure 51 Reconnecting the Power Cables to the Backplane

12V connector

Power supply

Backplane

6-pin connector

Front panel

Power connector

Installing the Power Supply

45

Removing and Installing the Cisco AS5400 Power Supply

Step 4

Route the fan cables as shown in Figure 52.

Note The two longest cables are connected to the two installed fans on the right. The connectors to these two fans fit into the space between the second and third fans.

Caution

Route the fan cables carefully to avoid pinching the cables near the bridge lance. (See Figure 52.)

Figure 52 Routing the Fan Cables

Front panel

Sheet metal tabs

Bridge lance

Base tabs

Step 5

Insert the second fan and press the fan into place between the sheet metal tabs. (See Figure 52.)

Note Make sure that the fan cable feeds to your left, and position the cables to the two installed fans so that they fit under the first and second fans.

46

Installing the Power Supply

78-4519-04

Removing and Installing the Cisco AS5400 Power Supply

Step 6

Reconnect the two 2-pin fan cables to the remaining fan. (See Figure 53.)

Figure 53 Reconnecting the Fan Cables

Fan connector

Front panel

Fan

78-4519-04

Installing the Power Supply

47

Removing and Installing the Cisco AS5400 Power Supply

Step 7

Reinstall the remaining fan. When correctly assembled, the cables appear as shown in Figure 54.

Note Make sure that you orient the fan so that the cables feed to the right (toward the second fan).

Then route the cable completely under the fan before you reconnect it. This takes up the extra length of fan cable and keeps it out of the way.

Figure 54 Correct Fan Cable Routing

48

Installing the Power Supply

78-4519-04

78-4519-04

Removing and Installing the Cisco AS5400 Power Supply

Step 8 Replace the air separator, holding all cables to the right of the separator as you slip it into the chassis.

(See Figure 55.)

Figure 55 Replacing the Air Separator

Air separator

4

Front panel

Step 9

Turn the chassis so that you face the rear panel, and reinstall the three mounting screws. (See Figure 56.)

Figure 56 Replacing the Redundant Power Supply Mounting Screws

Mounting screws

AC OK

DC OK

OTF

AC OK

DC OK

OTF

Power supply

Step 10

Replace the chassis cover using the procedures in the following section, “Replacing the Chassis Cover.”

Installing the Power Supply

49

Removing and Installing the Cisco AS5400 Power Supply

Replacing the Chassis Cover

To replace the chassis cover, follow these steps:

Step 1

Step 2

Place the chassis bottom so that the front panel is facing you.

Hold the chassis cover over the chassis bottom, and align each of the cover tabs with the chassis tabs at

the top rear of the chassis. (See Figure 57.)

Figure 57 Replacing the Chassis Cover

Chassis tabs

Cover tabs

Cover

4

Front panel Chassis bottom

Step 3 Lower the front of the top cover to close the chassis, and ensure the following:

The chassis cover tabs fit under the edge of the chassis rear panel so that they are not exposed.

The chassis tabs fit under the chassis cover so that they are not exposed.

• The chassis cover side tabs on both sides fit inside the chassis side panels so that they are not exposed.

When the chassis cover is properly assembled, no tabs are visible, as shown in Figure 58.

50

Replacing the Chassis Cover

78-4519-04

Figure 58 Cisco AS5400 Chassis

Removing and Installing the Cisco AS5400 Power Supply

78-4519-04

Step 4

Step 5

Step 6

Step 7

Secure the chassis cover with four screws. (See Figure 57.)

Reinstall the chassis on a rack, desktop, or table.

Reinstall all interface cables.

Reconnect the AC power cords. Or, if you are using a DC-powered unit, refer to Figure 59, and complete

Steps a through d.

Warning The illustration shows the DC power supply terminal block. Wire the DC power supply using the appropriate wire terminations at the wiring end, as illustrated. The proper wiring sequence is ground to ground, return to return, and negative to negative. Note that the ground wire should always be connected first and disconnected last. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Figure 59 DC Power Supply Connections

Mounting screw

Strain-relief clamps

Mounting screw

LEDs

IN OK

DC OK

OTF

On/off switch

LEDs

IN OK

DC OK

OTF

Mounting screw

Strain-relief clamps

Terminal block

Terminal block

Replacing the Chassis Cover

51

Removing and Installing the Cisco AS5400 Power Supply

Caution Do not over torque the terminal block contact screws. The recommended torque is 5.0 in.-lb (0.56 N-m).

a.

b.

c.

d.

Insert the safety ground (green wires) into the terminal block ground connectors and tighten the locking screws. Ensure that no bare wire is exposed.

Insert the 48 VDC Return wires into the terminal block positive connectors (+) and tighten the locking screws. Ensure that no bare wire is exposed.

Insert the -48 VDC wires into the terminal block negative connectors (-) and tighten the locking screws. Ensure that no bare wire is exposed.

Make sure that the power supply cords are secured to the cable strain-relief clamps on the DC power supply with cable ties.

Warning After wiring the DC power supply, remove the tape from the circuit breaker switch handle and reinstate power by moving the handle of the circuit breaker to the ON position. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety

Information document that accompanied this device.

Note You can order a Y-connector (CAB-AC-Y) to plug into both power connectors in the power supply. If you use this Y-connector, you will remove the backup feature of this power supply by eliminating redundant operations and reducing reliability. Cisco highly recommends that you use both power cords whenever possible.

Step 8 Power ON the universal gateway.

The internal power supply fan should power on. If you are using a redundant power supply, the six green

LEDs on the front of the power supply should light. If one LED is not lit, consult the appropriate redundant power supply software message to determine where the problem is located.

Verifying Status of the Redundant Power Supply

To display the current status of the Redundant Power Supply unit, enter the show environment command.

Router# show environment

Power Supply:

Redundant Power System is present.

RPS Input Voltage status: normal

RPS Output Voltage status: normal

RPS Fan status: normal

RPS Thermal status: normal

RPS OverVoltage status: normal

Board Temperature:

normal

Router#

52

Verifying Status of the Redundant Power Supply

78-4519-04

Obtaining Documentation

Configuring the Power Supply Alarm

You can configure the Cisco IOS software to poll every second to detect the failure of the redundant power supply. By default, the facility alarm is off. To begin monitoring the redundant power supply, enter the facility-alarm detect command. To disable the alarm, enter the no version of the command.

To configure alarm support for the redundant power supply, follow these steps:

Command

Step 1 Router> enable

Password: password

Router#

Purpose

Enter enable mode and enter the password.

Step 2 Router# configure terminal

Step 3 Router(config)# facility-alarm detect rps

You have entered enable mode when the prompt changes to

Router#

.

Enter global configuration mode.

Turns on alarm when a redundant power supply failure is detected. Any of the following failures turn on the alarm:

• I/P voltage failure

O/P voltage failure

Overvoltage condition

Multiple failures

Verify Alarm Configuration

To verify the status of the alarm configuration, enter the show facility-alarm command:

Router# show facility-alarm

Device State

------ -----

FastEthernet0/0 UP

Modem Card 4 UP

Facility Alarm is ON

Note For information on connecting alarm devices to the alarm port on the Cisco AS5400, refer to the

Cisco AS5400 Universal Gateway Chassis Installation Guide.

Obtaining Documentation

These sections explain how to obtain documentation from Cisco Systems.

78-4519-04

Configuring the Power Supply Alarm

53

Obtaining Documentation

World Wide Web

You can access the most current Cisco documentation on the World Wide Web at this URL: http://www.cisco.com

Translated documentation is available at this URL: http://www.cisco.com/public/countries_languages.shtml

Documentation CD-ROM

Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.

Ordering Documentation

You can order Cisco documentation in these ways:

• Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from the Networking Products MarketPlace: http://www.cisco.com/cgi-bin/order/order_root.pl

Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription

Store: http://www.cisco.com/go/subscription

Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters (California, U.S.A.) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).

Documentation Feedback

You can submit comments electronically on Cisco.com. In the Cisco Documentation home page, click the Fax or Email option in the “Leave Feedback” section at the bottom of the page.

You can e-mail your comments to [email protected].

You can submit your comments by mail by using the response card behind the front cover of your document or by writing to the following address:

Cisco Systems

Attn: Document Resource Connection

170 West Tasman Drive

San Jose, CA 95134-9883

We appreciate your comments.

54

World Wide Web

78-4519-04

Obtaining Technical Assistance

Obtaining Technical Assistance

Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain online documentation, troubleshooting tips, and sample configurations from online tools by using the Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC Web Site.

Cisco.com

Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.

Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a broad range of features and services to help you with these tasks:

• Streamline business processes and improve productivity

Resolve technical issues with online support

Download and test software packages

Order Cisco learning materials and merchandise

Register for online skill assessment, training, and certification programs

If you want to obtain customized information and service, you can self-register on Cisco.com. To access

Cisco.com, go to this URL: http://www.cisco.com

Technical Assistance Center

The Cisco Technical Assistance Center (TAC) is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two levels of support are available: the Cisco TAC

Web Site and the Cisco TAC Escalation Center.

Cisco TAC inquiries are categorized according to the urgency of the issue:

Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities, product installation, or basic product configuration.

Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably impaired, but most business operations continue.

Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects of business operations. No workaround is available.

Priority level 1 (P1)—Your production network is down, and a critical impact to business operations will occur if service is not restored quickly. No workaround is available.

The Cisco TAC resource that you choose is based on the priority of the problem and the conditions of service contracts, when applicable.

78-4519-04

Obtaining Technical Assistance

55

Obtaining Technical Assistance

Cisco TAC Web Site

You can use the Cisco TAC Web Site to resolve P3 and P4 issues yourself, saving both cost and time.

The site provides around-the-clock access to online tools, knowledge bases, and software. To access the

Cisco TAC Web Site, go to this URL: http://www.cisco.com/tac

All customers, partners, and resellers who have a valid Cisco service contract have complete access to the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a

Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to this URL to register: http://www.cisco.com/register/

If you are a Cisco.com registered user, and you cannot resolve your technical issues by using the Cisco

TAC Web Site, you can open a case online by using the TAC Case Open tool at this URL: http://www.cisco.com/tac/caseopen

If you have Internet access, we recommend that you open P3 and P4 cases through the Cisco TAC

Web Site.

Cisco TAC Escalation Center

The Cisco TAC Escalation Center addresses priority level 1 or priority level 2 issues. These classifications are assigned when severe network degradation significantly impacts business operations.

When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer automatically opens a case.

To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml

Before calling, please check with your network operations center to determine the level of Cisco support services to which your company is entitled: for example, SMARTnet, SMARTnet Onsite, or Network

Supported Accounts (NSA). When you call the center, please have available your service agreement number and your product serial number.

This document is to be used in conjunction with the documents in the “Related Documentation” section on page 4.

CCVP, the Cisco logo, and Welcome to the Human Network are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco

Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,

Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networkers,

Networking Academy, Network Registrar, PIX, ProConnect, ScriptShare, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.

All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0711R)

Copyright © 2001-2003 Cisco Systems, Inc.

All rights reserved. Printed in USA.

56

Technical Assistance Center

78-4519-04