OMRON - Electric Automation Network

OMRON - Electric Automation Network
At the end of this document you will find links to products related to this catalog. You can go directly to our shop by
clicking HERE. HERE
Y201-EN2-03.book Seite 591 Donnerstag, 30. März 2006 1:52 13
Human Machine Interfaces
592
594
595
609
612
615
618
622
623
Human Machine
Interfaces
Introduction to OMRON HMI
HMI Overview
NS series Advanced Touch Screens
NT series Touch Screen
NT series Function Key screens
NT-XS series Touch Screen
NT-XS series Function Key Screens
RS-232C/RS-422A Adapter
Ordering Information
591
Y201-EN2-03.book Seite 592 Donnerstag, 30. März 2006 1:52 13
Introduction to OMRON HMI
HMIs for essentially any purpose
Model
Type of display
NS12
TFT 12 inch
colour display
241x215x48.5
NS10
TFT 10 inch
colour display
NS8
TFT 8 inch
colour display
177x232x48.5
NS5-T
NS5-S / NSH5-S
NS5-M
TFT 5.7 inch
STN 5.7 inch
STN 5.7 inch monocolour display
colour display
chrome display
142x195x54
NSH5 176x223x70.5 (depth excl. emergency button)
Effective display area
246x184.5 mm
(800 x 600 pixels)
215.2x162.4 mm
(640 x 480 pixels)
170.9x128.2
(640 x 480 pixels)
117.2x88.4 mm
(320 x 240 pixels)
Display colour
256 colours
Image data: 32,768 colours
Size in mm
(HxWxD mm)
256 colours
Image data:
4,096 colours
Power supply
24 V DC ±15%
Touch panel
Obtained standards
38 vertical x
30 vertical x
24 vertical x
50 horizontal
40 horizontal
32 horizontal
UL 1604 C1D2, cUL, EC Directives, NEMA equivalent
Display graphics
Rectangle, circle, oval, straight line, polyline, polygon, arc
No. of display characters (stan- 100 characters x
dard characters)
37 lines
16 grey scales
15 vertical x 20 horizontal
80 characters x 30 lines
No. of registered screens
3,999 screens max. (depending on screen contents)
Screen data capacity
(standard)
60 MB
Memory card interface
ATA compact flash card interface, 1 slot
20 MB
Internal memory
Bit memory: 32,767 bits, Word memory: 32,767 words, Retentative memory: 8,192 bits and 8,192 words.
Printer connection
Supported
Backlight life
50,000 hours minimum
Multivendor support
Supported for most third-party PLCs.
Please contact your local OMRON distributor for more information.
Video board
(composite / RGB)
Supported
Model
Features
NSJ5
A combination of a fast and powerful CJ1 PLC, a 5.7'' NS series touchscreen and open network connections.
With the NSJ5 you are able to configure, commission, operate and maintain your complete automation solution. Ideal for applications
that require visualisation, control and open network connection with little space. Panelless automation by making use of remote I/O
terminals and intelligent devices.
- 5.7“ colour touchscreen, 4096 colours (images), 20 MB screen data memory
- 20 k Steps PLC program memory
- 32 K Words PLC data memory
- DeviceNet or CAN interface
- Ethernet interface
- Compact Flash card interface
592
--40,000 hours minimum
---
75,000 hours minimum
---
50,000 hours minimum
---
Human Machine Interfaces
Y201-EN2-03.book Seite 593 Donnerstag, 30. März 2006 1:52 13
Select the HMI that suits your application best
NT11–SF121(B)1.
113x218x38.2
160x64 mm
NT2S-SF12†B-E(V2)
60x108x43
56x11 mm
Type with ethernet
NT21S-ST121(B)1
110x190x58
117x63 mm
(260x140 dots)
24 VDC +10%/-15%
24 VDC ±15%
I/O
-
22 keys
24 VDC ±10%
(when applicable)
6 to 20 keys depending on
model
--CE, cULus
Function keys
Touch panel
Obtained standards
Display graphics
No. of display characters (standard
characters)
No. of registered screens
Screen data capacity (standard)
Expansion memory
Memory card interface
Expansion interface
Ethernet
Internal memory
Ladder monitor
Programming Console function
Device monitor
Barcode reader connection
Printer connection
Multivendor support
Backlight life
1.
2.
7 vertical x 13 horizontal
--UL, CSA, EC Directives,NEMA CE, cULus
equivalent
Straight lines, rectangles, polygons, circles, ovals, sector, bitmaps
16 characters x 8 lines
20 characters x 4 lines
3,999 screens max.
(depending on screen contents)
512 KB
--NT-MF261 memory unit for
screen transfer can be used.
----Numeral memory table: 2,000
entries max., Character memory
table: 2,000 entries max.
--Supported
--Supported
--Supports most third party
PLCs. 2.
50,000 hours average
NT3S-ST12†B-E
77x140x35
98x35 mm
(192 x 64 pixels, 4.1 inch)
24 VDC ±15%
Analog Resistive
CE, cULus
Rectangle, rounded rectangle,
circle, oval, line, bitmaps
16 characters x 2 lines
32 characters x 8 lines
250
250
65,000 max.
(limited by memory capacity)
32 KB
-----
24 KB
-----
120 KB
-----
-----
----1 kWords data,
1 kWords retentative memory
----1 kWords data,
1 kWords retentative,
64 words system memory
--------Supported
---
--------Supported
Supports most third
party PLCs 2
LED, min. 50,000 hours
--------Supported
Supports most third
party PLCs 2.
LED, min. 50,000 hours
50,000 hours average
Human Machine
Interfaces
Model
Size in mm (HxWxD)
Effective display area
Model numbers with ’B’ have a black frame and without a beige frame.
Please contact your local OMRON representative for a list of available drivers.
Introduction to OMRON HMI
593
Y201-EN2-03.book Seite 594 Donnerstag, 30. März 2006 1:52 13
HMI Overview
As a machine management tool ... as an
information terminal ... as a system component
As a global supplier of HMI solutions and high-reliability industrial touch screen technology for over 12
years, Omron has supplied more than 500,000 pieces of HMI through more than 200 world-wide sales
and support offices each offering after-sales support, service and training in the local language.
We also understand the changing needs of our customers. As control systems become more complex
the HMI is increasingly being used not only as an operator display and data-setting terminal, but also as
a maintenance tool for the complete control system. Many HMI applications now contain 100’s of
screens of maintenance information for the complete control system and Omron's easy software and
hardware integration within the control system can greatly reduce programming time needed and also
greatly increase the functionality of the maintenance, therefore dramatically reducing the total cost of
ownership.
Higher
Select by screen size. Select by functions.
The wide range of NT- and NS-series HMIs
suits most applications.
NS5 (TFT)
NS8 (TFT)
Functionality
320 × 240 dots
640 × 480 dots
NS10 (TFT)
640 × 480 dots
NS12 (TFT)
800 × 600 dots
NS5
(STN colour)
320 × 240 dots
NS5 (Monochrome)
320 × 240 dots
NT3S
NT21
Lower
(STN monochrome)
260 × 140 dots
Smaller
594
NT2S
NT11
2 lines
(STN monochrome)
160 × 64 dots
Screen size
Larger
Human Machine Interfaces
Y201-EN2-03.book Seite 595 Donnerstag, 30. März 2006 1:52 13
NS5, NS8, NS10, NS12
NS series Advanced Touch Screens
Design Software
The CX-Designer is used to create screen data for NS-series
Programmable Terminals. The CX-Designer can also be used to test
the operation of the created screen data on the computer.
Sheet
Screen
Screen Creation
Screen templates
Make one common screen (sheet) that overlaps other screens (to save
having to recreate the same part, such as a menu, in every screen).
A feature that is common to several screens can be registered in a
sheet. The common feature can be added to any screen just by
applying the corresponding sheet to the screen. (Up to 10 sheets can
be created for one project.)
Resulting screen
with sheet applied
The feature in
the sheet is
added.
Multiple language support
Switching error messages between English and Japanese
Making multiple language versions with a single screen data file
A Dual-language (English/Japanese) system program
With an NS-series PT, the display language for the system menu and
error messages can be switched between English and Japanese with
the System Menu’s Select Language function. Like the Label Switching
function, the Dual-language setting is useful for exported products
because the language can be set to English for normal operation and
switched to Japanese when Japanese staff need to operate the
equipment or perform maintenance.
Label switching function
Up to 16 groups of labels (labels 0 to 15) can be registered for
functional objects such as buttons, lamps, labels, and alarm settings.
(Each label can correspond to a different language, for example,
label 0 = Japanese, label 1 = Simplified Chinese, label 2 = Korean,
label 3 = English, etc.)
Once all of the labels have been input in each language with the
multilingual input function, all of the labels can be switched to a different
language at once just by specifying the corresponding label number
from the PLC.
Language selection tab page
Creating Italian, German, or Other Language Screens in any
language version of Windows
Multi-language Input (When Windows 2000 or XP is Used)
When Windows 2000 or XP is being used, French, German, Spanish,
Italian, and other language text can be input in NS-Designer. Select the
desired language with regional options to input a different language.
Example: The label switch function can be used to switch between
English and Simplified Chinese.
Having a text label converted into multiple languages by a
translation company
CSV File Input/Output
The labels for each functional object can be exported in CSV format.
The changed labels can be imported again after it has been edited with
a program such as Excel.
NS series Advanced Touch Screens
595
Human Machine
Interfaces
Develop Screens More Efficiently with Easy-to-use Support Software.
The CX-Designer has about 1,000 standard functional objects with
associated graphics and advanced functions, so even first-time users
can create screens easily just by arranging functional objects in a
screen.
The CX-Designer is also equipped with a variety of functions that make
it easy to create screens for common applications. Screen
development is very efficient with the CX-Designer.
Y201-EN2-03.book Seite 596 Donnerstag, 30. März 2006 1:52 13
Transferring Screen Data
Data Transfer by Passing Through a PLC or PT!
SPMA (Single Port Multi Access) Function
When transferring screen data from the CX-Designer to the NS-series
PT, the data can be transferred through a PLC as long as the PT is
connected to the PLC by a serial connection or network connection.
Also, when monitoring/transferring a PLC ladder program from the
CX-Programmer, the PLC ladder program can be monitored/
transferred through an NS-series PT as long as the PT is connected to
the PLC by a serial connection or network connection.
Screen data or Data in Memory Card
(From CX-Designer through PLC to NS-series PT)
SPMA
Ladder program
(From CX-Programmer through NS-series PT to PLC)
Computer
· CX-Designer
version 3.0 or higher
· CX-Programmer
version 3.1 or higher
Ethernet
NS-series PT
CS/CJseries
PLC
Peripheral
(or RS-232C)
NS-series PT
CS/CJ-series PLC
Serial
Peripheral
bus
(Tool bus)
Serial
RS-232C
NT Link/Hostlink
Computer
· CX-Designer
version 3.0 or higher
· CX-Programmer
version 3.1 or higher
Serial
NT Link
Controller Link
NS-series PT
CS/CJ-series PLC
* To use the SPMA function through the PLC, the following software
and hardware versions are required.
•
•
•
•
NS-series PT: System version 3.0 or higher
CX-Designer: Version 3.0 or higher
CX-Programmer: Version 3.1 or higher
PLC: Lot No. 030201 and later
Easy screen data transfer at high speed
596
Human Machine Interfaces
Y201-EN2-03.book Seite 597 Donnerstag, 30. März 2006 1:52 13
Human Machine
Interfaces
Easy screen data transfer at high speed
NS series Advanced Touch Screens
597
Y201-EN2-03.book Seite 598 Donnerstag, 30. März 2006 1:52 13
Creating Windows-style screens
Making buttons pop-up with a single property setting
Easily creating pop-up menus
You can easily create your own pop-up menu using the standard
command button. When the button is pressed, the pop-up menu will be
displayed and the corresponding operation (such as switching screens
or setting a value in a specified communications address) can be
performed by choosing the item name from the pop-up menu.
Using Excel to analyze data, such as the Alarm/Event History,
Operation Log, and Error Log, and to create Daily Reports
Memory Card: data logging function
Log Data in a Memory Card can be read on the screen with the read file
button. A list fo files with time stamps will appear on the screen. By
selecting the desired file, the past log in the Memory Card ban be read.
The log data files in the Memory Card
appear as shown bellow when the read file
button is pressed
Inputting character strings by selecting from a list
List selection object
The character strings in the specified PLC addresses or text file are
displayed so that the user can select from the list. When a line is
selected, the corresponding line number or character string can be
written to the PLC. It is possible to display up to 1,024 lines with up to
256 characters in each line.
Switching just part of the screen, Like the Pages of a Notebook
Frame function
It is possible to specify an area in the screen (Frame) that will be
switched as a page. Up to 10 frames can be set for one screen. Up to
256 pages can be switched for one frame.
This function can be used for operations such as switching tabs.
Number of Frames (Tabs): 5
Tab for product A is active.
Tab for product B is active.
Varying the font size, just as you can in a word processor
Windows fonts function
Windows fonts such as Arial or Century can be used for text objects and
the font size can be changed.
Using an image, e.g. a picture taken with a digital camera, for the
background
Bitmap displays
It is possible to display BMP and JPG files. The files can be specified
directly or indirectly.
Background files
It is also possible to arrange BMP and JPG files for the background of
the screen.
Using general software
Editing text and bitmap file with your favorite text editor
Editor specifying function
The user can select the editor when editing text or bitmap files.
Creating system-related documents
Outputting project information in RTF
Data such as screen information and object information can be output
in an RTF file. The RTF file can be read into Word Processor to produce
a system manual.
Read file button
Using Excel to analyze time-series data and to create daily reports
Memory Card: History Storage Function
The following data can be saved to the Memory Card in CSV format.
• Alarm/Event History (Alarm/ Event history data)
• Operation Log (Screen operation history data)
• Error Log (Error log data recorded during macro program execution)
Easily utilizing advanced functions
Setting and displaying recipe data from the PT for fast production
changeovers
Data block (Recipe) function
Data blocks (recipe function)
allow several numeric values
and/or character strings to be
transferred to/from memory
areas, such as PLC data
areas. Data blocks can be
used to change the system’s
production setup even faster.
Select product
B’s information and
set it in the PLC.
NS-series PT
CS/CJ-series
PLC
Data Block
Width
Height
Color
Product A
100
52
Red
Product B
150
54
Blue
Product C
200
56
Yellow
Product D
300
62
Red
Product E
400
64
Blue
To other
equipment
Product B
Easily creating screens in table format containing multiple
functional objects
Tables
The same kind of functional objects (such as Buttons, Text, or Numeral
Display & Input objects) can be created together in a table just by
specifying the kind of functional object, number of rows, and number of
columns in the table. In addition, the properties for functional objects
can all be set together and PLC addresses can be allocated
automatically. It is also possible to add headings for each row and
column.
Converting the scale for industrial units at the PT
Units setting and scaling function
The display units and scale can be changed Numeral Display & Input
objects. Any unit display can be set.
Hide or disable objects on a screen with a single bit to prohibit
operation
Control flag (Interlock) function
A bit in the PLC can be used as a control bit to control the display of an
object (such as a button or numeral input) or disable/enable an
operation.
This can be useful when you want to change data from a PLC without
the user noticing this. It can also guide the user to perform actions step
by step.
Example of an RTF File Read into Word Processor
Pasted Screen Data as
RTF Data
Object Properties as
RTF Data
Protecting the system with passwords
Passwords
It is possible to register 5 kinds
(levels) of passwords (16
characters max.) for the whole
project. Also can set one of 5
passwords for each functional
object (which you operate).
Changing the color of an area of the Meter to indicate an error level
Switch display color function
Level Meter and Analogue Meter can be divided into three ranges with
a different fill color in each range. It is also possible to indirectly specify
each range’s color and border values so that the ranges can be
changed during operation.
598
Human Machine Interfaces
Y201-EN2-03.book Seite 599 Donnerstag, 30. März 2006 1:52 13
Sharing Screen Data
Create customized functionality using script
(Moving functional objects based on the status of PLC bits, performing conditional processing at a given present
Using Image library
value, writing to the PLC according to set value arithmentic operations, etc.)
Macro function
Original, user-defined programs (macros) can be added and executed
to control projects, screens, and functional objects.
Select Shape Function
About 1,000 shapes can be used for ON/OFF buttons, Bit lamps, and
Word lamps, including shapes such as 7-Segment digits, rotary
switches, limit switches, and motors.
Registering Complex Objects such as Graphics to a Library and
Reusing Them
Library Register Function
Organize functional objects or fixed objects that you have created and
register them in the library so that they can be reused.
Terminal Software
Monitoring and setting PLC data
Device Monitor Function
The Device Monitor Function is a standard feature in the NS-series
Programmable Terminals. Data in the PLC’s I/O memory can be
accessed directly (read and written.) The Device Monitor provides
functions that can significantly reduce the time needed to set up the
system, such as displaying a block of consecutive PLC data area
addresses and inputting/verifying parameters in CPU Bus Units and
Special I/O Units.
Monitoring Execution of the PLC's Ladder Program
Ladder Monitor Function
Save the NS-EXT01 Ladder Monitor system program on a Memory
Card (the NS-EXT01 is sold separately) and install the Memory Card to
enable monitoring of a ladder program (I/O bit status monitor, address/
instruction search, multiple I/O bit monitor, etc.) being executed in a
CS/CJ-series PLC connected by a serial connection. It is also possible
to display I/O comments created with the CX-Programmer.
Memory Card: Upload/Download Function
It is possible to download the screen data and system program to
Memory Card and upload the same data from the Memory Card. It is
also possible to automatically upload the data from the Memory Card to
CX-Designer or automatically download the data from Memory Card to
PT when the power of PT is turned ON.
You can partially replace text and pictures from your computer.
Easily Displaying the Status of Particular Bits in Ladder Programs
when Errors Occur
Switch Box Function
The Switch Box Function has been added to the NS-series
Programmable Terminals. The Switch Box Function can be used to
monitor the status of each bit in a word or a combination of userselected bits organized like a ladder program section. The Switch Box
Function makes it possible to perform basic troubleshooting on the
factory floor or debugging of the application even without a computer.
FTP (File Transfer Protocol) has been added!
Texts, lists, and
recipes can be
replaced with the
put/get command
from your
computer! You can
even replace BMP
files online from
your computer easily.
The NS can be connected to a Board PC. The NS can also be directly connected to an OMRON Temperature Controller.
Memory Link has been added to the
communications method. It allows the
NS to communicate with a Board PC.
Ver.5
Memory link
The following models, which have an RS-485
communications port and support CompoWay/F
communications, can be connected to the NS.
Unit
Modular
Temperature
Controllers
Digital
Temperature
Controllers
Digital
Controllers
OMRON Temperature
Control Unit
NS series Advanced Touch Screens
The NS can communicate directly
with the OMRON Temperature
Controllers listed on the right
using a RS-485 adapter.
Series
E5ZN
Model
E5ZN-SCT24S-500 (terminal unit)
E5AN
E5AN-
M -500 + E53-AK03
E5EN
E5EN-
M -500 + E53-AK03
E5CN
E5CN-
E5GN
E5GN-
M -500 + E53-CNH03 or E53-CN03
E5AR
E5AR-QC43DB-FLK
03 -FLK
E5AR-QQ43DW-FLK
E5AR-CC43DWW-FLK
E5ER
E5ER-QC43B-FLK
E5ER-PRQ43F-FLK
E5ER-QT3DW-FLK
E5ER-CT3DW-FLK
599
Human Machine
Interfaces
Monitoring PLC I/O data for the purpose of device debugging and
maintenance
Y201-EN2-03.book Seite 600 Donnerstag, 30. März 2006 1:52 13
Printer Support
Exchanging data with a PLC over a network (Multihost)
USB port compatibility with commercially available printers
Hard copies of screens can be printed out in color by USB-compatible
printers or to the flash card.
Communicating with a PLC via NT Link, using Ethernet without
special PLC Programming
USB port included as
standard equipment
General printer compatible
with USB port
USB cable
Ethernet communications without programming
NS-series PTs can communicate with a CS/CJ-series PLC (equipped
with an Ethernet Unit) through “program-free” communications just like
NT Link communications. Data is transferred through Ethernet through
a simple PLC address and initial communications setup.
Using data links between the PT and the PLC
EPSON and Canon printers supported.
NS5
-
NS8
Supported
NS10
Supported
NS12
Supported
Supported Printers
Manufacturer
EPSON
CANON
Model
Stylus Photo 830U
Stylus Photo 870U
Stylus Photo 900
Stylus Photo 925
Stylus Photo 720
Stylus C62
PIXMA iP90
PIXMA iP2000
PIXMA iP3000
PIXMA iP4000
PIXMA iP4000R
BJ i80
BJ i70
BJC-85
NS system version
v5
v5
v5
v5
v5
v5
v6.20
v6.20
v6.20
v6.20
v6.20
v5
v5
v5
Controller Link interface unit
The Controller Link is an FA network that can send and receive large
data packets flexibly and easily among OMRON PLCs and IBM PC/AT
or compatible computers. The NS12 and NS10 PTs can be connected
to the Controller Link network easily via a Controller Link Interface Unit.
When a Controller Link network is used, data can be transferred
between multiple PLCs and NS12/NS10 PTs without writing ladder
programming to manage the communications.
System Configurations
Various connections, such as 1:1, 1:2, 1:N, and M:N, are supported
with Ethernet or serial connections
PT:PLC = 1:1
PT:PLC = 1:2
PT:PLC = 1:N
PT:PLC = M:N
Host Registration Function
It is possible to register two or more PLCs as hosts and communicate
with the PLCs by specifying the host ID and address.
Hardware
Using Video Inputs
Capturing Moving Images from a Video Camera and Image
Outputs from a Vision Sensor
Video Input Interface
Four video input interfaces are
provided, so four video or CCD
cameras can be connected. Up to
four images can be displayed
simultaneously if the image size is
320x240 pixels.
Image capture data read function
BMP data captured and saved in a Memory Card can be read on the
PT. BMP data displayed in thumbnails can be selected and displayed
on the captured data display screen that will appear for the command
button. If any error occurs, the image when the error accurred can be
displayed on the NS screen. This is useful for on-site error analysis.
Using for Process Control
Automatically Generating PT Image Data from Tag Information
Created with CX-Process
Console
Camera
Display PC Screens with the NS-CA002
NS-CA002 RGB/Video Input Unit
(Supported by the NS12-V1/
NS10-V1/NS8-V1)
An analog RGB input terminal is
provided in addition to two video
input interface terminals. A single
RGB
video or analog RGB display is
possible in user-defined positions
and sizes. Touch switches and
parts, such as lamps, can be
overlapped on the video display.
The display of parts will not disappear.
Face Plate Auto-Builder for NS (Sold separately)
Significantly reduces the engineering time required, by combining LCB/
LCU and the NS Series.
• Automatic generation of control screens and tuning screens.
Automatic generation of NS screen data by the software from tag
information created with the CX-Process Tool.
• NS communications address allocation, ladder programs, etc., are
completely unnecessary.
• Data that has been generated can be freely edited and processed by
CX-Designer (NS screen creation software).
Console
Created screens
are easily
transferred to the
NS by means of a
Memory Card or
over the network.
NS Series
Camera
Saving Displayed Video Images to a Memory Card in BMP Format
Image Capture Function
When necessary, the displayed image can be captured and saved in a
Memory Card in BMP format. The saved image can then be uploaded
from a personal computer via Ethernet or Serial connection. It is also
possible to display the saved image on the NS screen again, so that
you can compare two or more captured images immediately.
The number of images that can be saved depends on the capacity of
Memory Card. As an example, about 50 images from a 640x480
display (about 600 Kbytes each) can be saved in a 30-Mbyte Memory
Card.
600
SYSMAC CS1+LCU
CSV tag file
for LCU/LCB
NS project
file
NS-Designer
(NS screen creation
software)
Editing created data
Creation of other
required screens
CX-Process Tool
(LCU/LCB programming
software)
LCU/LCB program creation
(function block method)
CSV tag file output
Face Plate Auto-Builder
for NS
Human Machine Interfaces
Y201-EN2-03.book Seite 601 Donnerstag, 30. März 2006 1:52 13
High-reliability and advanced functions in the industry’s slimmest PT
Super-thin 48.5-mm Body for a Slimmer Control Panel
NS12, NS10
Memory Card interface
Memory Card
Expansion interface
Battery
RS-232C serial port A
Ethernet (10Base-T or 100Base-T)
USB HOST
USB SLAVE (Screen data transfer)
RS-232C serial port B
A barcode reader can be connected
to the serial port.
Human Machine
Interfaces
Power Supply (24 VDC)
Recommended barcode reader: V520-RH21-6
NS8
Memory Card interface
Expansion interface
Memory Card
Note: Colors shown in photographs and product
names may differ from actual colors and
names.
Battery
RS-232C serial port A
Power
Supply
(24 VDC)
USB HOST
RS-232C serial port B
USB SLAVE (Screen data transfer)
NS series Advanced Touch Screens
Ethernet
(10Base-T or 100Base-T)
A barcode reader can be connected
to the serial port.
Recommended barcode reader: V520-RH21-6
601
Y201-EN2-03.book Seite 602 Donnerstag, 30. März 2006 1:52 13
NS5
Memory Card interface
Memory Card
Expansion interface
Ethernet (10Base-T or 100Base-TX)
USB SLAVE (Screen data transfer)
Battery
RS-232C serial port A
Power Supply
(24 VDC)
RS-232C serial port B
A barcode reader can be connected
to the serial port.
Recommended barcode reader: V520-RH21-6
Built-in Expansion Interface
The NS-series PTs have a built-in Expansion Interface for future
expandability.
USB Ports
A printer can be connected to the USB HOST port. Be sure to use USB
cables made by OMRON (NS-US52/NS-US22).
NS-series PTs have backlights with the longest life expectancy in
the industry.
At room temperature, the average life expectancy is 50,000 hours min.
for the NS12, NS10, NS5 and 40,000 hours min. for the NS8.
Optional Products
Ladder Monitor program
Video Input Unit (with Cover)
RGB/Video Input Unit
(with Cover)
Controller Link Interface Unit
(with Cover)
Memory Card
Memory Card Adapter
RS-422A Adapter
RS-232/RS-422A Conversion
Unit
CJ1W-CIF11
Communications Cable
Protective Cover/Anti-reflection
Sheet for NS-series PT
NS-AL002
USB Serial Conversion Cable
Note: Colors shown in photographs
and product names may differ
from actual colors and names.
CS1W-CIF31
602
Human Machine Interfaces
Y201-EN2-03.book Seite 603 Donnerstag, 30. März 2006 1:52 13
Dimensions
NS12/10
NS8
Units: mm
Units: mm
165 188
177
140 241
227 249
15.5
15.5
5
180
232
7.5
264
315
323
48.5
48.5
39 (min.)
42 (max.)
39 (min.)
42 (max.)
49
49
220
301
Recommended
Panel Cutout Dimensions
SW
RESET
Recommended
Panel Cutout Dimensions
+1
120.5
165.5 –0
24V
DC
PORT B
HOST
107.6
PORT A
SLAVE
ETHERNET
SW
19.1
220.5 +1
–0
RESET
228 +1
–0
PORT B
HOST
PORT A
26.6
134
SLAVE
9.6
Human Machine
Interfaces
121
24V
DC
ETHERNET
44.1
63.4
50.1
302 +1
–0
13.7
3.8
23
49.9
90.4
NS5
Units: mm
39.83
‚q‚t‚m
OFF
OFF
OFF
142
OFF
24.6
27.3
‚c‚d‚e‚`‚t‚k‚s
130.5
‚Q‚S‚u
‚c‚b
‚c‚d‚e‚`‚t‚k‚s ‚m‚ D ‚e‚t‚m‚b‚s‚h‚n‚m F‚r‚s‚`‚s‚d
‚t‚o‚k‚n‚`‚c i‚n‚m j
OFF 5
‚c‚n‚v‚m‚k‚n‚`‚c i‚n‚e‚e j
‚l‚`‚m‚t‚`‚k i‚n‚m j
OFF 6
‚`‚t‚s‚n i‚n‚e‚e j
153.3
‚m‚ D ‚e‚t‚m‚b‚s‚h‚n‚m F‚r‚s‚`‚s‚d
‚a‚`‚m‚j‚P @‚r‚d‚k‚d‚b‚s i‚n‚m j
1
‚a‚`‚m‚j‚P @‚c‚d‚r‚d‚k‚d‚b‚s i‚n‚e‚e j
‚a‚`‚m‚j‚Q @‚r‚d‚k‚d‚b‚s i‚n‚m j
2
‚a‚`‚m‚j‚Q @‚c‚d‚r‚d‚k‚d‚b‚s i‚n‚e‚e j
‚a‚`‚m‚j‚R @‚r‚d‚k‚d‚b‚s i‚n‚m j
3
‚a‚`‚m‚j‚R @‚c‚d‚r‚d‚k‚d‚b‚s i‚n‚e‚e j
‚a‚`‚m‚j‚S @‚r‚d‚k‚d‚b‚s i‚n‚m j
4
‚a‚`‚m‚j‚S @‚c‚d‚r‚d‚k‚d‚b‚s i‚n‚e‚e j
‚r‚k‚`‚u‚d
PORT A
68.48
‚r‚v
RESET
44.55
PORT B
ETHERNET
‚R‚S @ i Å ¬ j
‚R‚[email protected] i Å‘å j
21
51.7
19.5
5
145
15.5
195
53.8
76.5
54.8
90
183.5
206.3
NS series Advanced Touch Screens
603
Y201-EN2-03.book Seite 604 Donnerstag, 30. März 2006 1:52 13
NS5 (STN color Handheld)
16.5
223
70.5
75
75
176
50
Four, M4
NS-CA001
Video Input
Unit
NS-CA002
Video Input
Unit
81.3
Units: mm
Units: mm
(102.7)
9.6
21.4
5
164
(169)
(1.9)
127.3
(22.3)
9.7 20.4
11
10.6
50.3
68.3
86.3
104.3
NS-CLK21
Controller Link
Interface Unit
Units: mm
151.5
(183)
31.5
5
164
(169)
(1.9)
10.8
(33.9)
32
11
95.6
604
Human Machine Interfaces
Y201-EN2-03.book Seite 605 Donnerstag, 30. März 2006 1:52 13
Performance/Specifications
General specifications
Specifications
24 V DC
20.4 to 27.6 V DC (24 V DC ±15 %)
25 W max.
0 to 50°C, 55°C for NS5 (See notes 1 and 2.)
-20 to 60°C (See note 2.)
35% to 85% (0 to 40 °C) with no condensation 35% to 60% (40 to 50 °C) with no condensation
No corrosive gases.
Conforms to IEC61000-4-4, 2 kV (power lines)
Conforms to IEC 60068-2-6, JIS C0040.
10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s² 30 min each in X, Y, and Z directions
Conforms to IEC 60068-2-27, JIS C0041. 147 m/s² 3 times each in direction of X, Y, and Z.
NS12: 2.5 kg max.; NS10: 2.3 kg max.; NS8: 1.8 kg max.; NS5: 1.0 kg max.
Front operating panel: IP65F and NEMA4 compliant (See note 3.)
5 years (at 25 °C). Replace battery within 5 days after the battery runs low (indicator lights orange).
cULus and EC directives
Note: 1. The operating temperature is subject to the following restrictions according to the mounting angle.
Mounting angle of 0 to 30× to the horizontal:
Operating temperature range of 0 to 45°C
When a Video Input Unit or a Controller Link Interface Unit is
mounted, the ambient operating temperature is 0 to 35°C.
Mounting angle of 30° to 90° to the horizontal: See note 4.
4. • Without any Expansion Unit Installed
- NS12-V1/NS10-V1/NS8-V1
Mounting angle of 0° to less than 30° to the horizontal:
Operating temperature range of 0 to 45°C
Mounting angle of 30° to 90° or less to the horizontal:
Operating temperature range of 0 to 50°C
- NS5 -V2
Mounting angle of 0° to 90° or less to the horizontal:
Operating temperature range of 0 to 55°C
2. Operate the PT within the temperature and humidity ranges
shown in the following diagram.
Humidity (%)
95% 80%
Storage
Operation
90˚
50
e
ac
urf
s
lay
p
Dis
Temperature (˚C)
0
Horizontal
(0˚)
40%
40
35%
30
30˚
—20 0
10
• With an Expansion Unit (Video Input Unit or Controller Link
Unit) Installed
- NS12-V1/NS10-V1
Mounting angle of 0° to less than 30° to the horizontal:
Operating temperature range of 0 to 35°C
Mounting angle of 30° to 90° or less to the horizontal:
Operating temperature range of 0 to 50°C
- NS8-V1
Mounting angle of 0° to less than 30° to the horizontal:
Operating temperature range of 0 to 35°C
Mounting angle of 30° to less than 90° to the horizontal:
Operating temperature range of 0 to 45°C
Mounting angle of 90° to the horizontal:
Operating temperature range of 0 to 50°C
60%
60
20%
20
10%
10
20 30 40 50 60
Temperature (˚C)
70
80
3. May not be applicable in locations with long-term exposure to
oil.
Characteristics
Display specifications
Item
Display
panel
Display device
Number of dots
NS12-V2
NS10-V2
NS8-V2
NS5T*-V2
NS5S*-V2
High-definition TFT color LCD
STN
800 dot horizontal x 640 dot horizontal x 480 dot vertical 320 dot horizontal x
600 dot vertical
240 dot vertical
256 colors
Display color
Backlight
(See note
4.)
NS5-M*-V2
Sixteen shades of
gray
Effective display area Width 246.0 mm x Width 215.2 mm x
height 184.5 mm
height 162.4 mm
(12.1 inches)
(10.4 inches)
Field of view
Left/right ±60°,
Left/right ±60°,
Top 45°, bottom 55° Top 35°, bottom 65°
Service life
50,000 hours min. (See note 1.)
Brightness
adjustment
Backlight error
detection
Width 162.2 mm x Width 117.2 mm x height 88.4 mm
height 121.7 mm
(5.7 inches)
(8 inches)
Left/right ±60°,
Left/right ±70°,
Left/right ±60°,
Top 50°, bottom 60° Top 70°, bottom 50° Top 30°, bottom 60°
40,000 hours min. 75,000 hours min. (see note1.)
50,000 hours min.
(See note 1.)
(See note 1.)
There are 3 levels that can be set with the touch panel. (See note 2.)
Error is detected automatically, and the
RUN indicator flashes green as
notification. (See note 3.)
---
Note: 1. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value. The service
life will be drastically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0°C will reduce the
service life to approximately 10,000 hours (reference value).
2. The brightness cannot be adjusted much.
3. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or
other errors. Backlight error detection indicates that all backlights (2) are OFF.
4. Contact your nearest OMRON representative to replace the backlight.
NS series Advanced Touch Screens
605
Human Machine
Interfaces
Item
Rated power supply voltage
Allowable voltage range
Power consumption
Ambient operating temperature
Storage temperature
Ambient operating humidity
Operating environment
Noise immunity
Vibration resistance
(during operation)
Shock resistance (during operation)
Weight
Enclosure rating
Battery life
Applicable standards
Y201-EN2-03.book Seite 606 Donnerstag, 30. März 2006 1:52 13
Operating specifications
Item
Touch panel Method
(Matrix type) Number of switches
Input
Service life
Standard screen data capacity
NS12-V2
NS10-V2
Resistive membrane
1,900
1,200
(50 horizontal x 38 (40 horizontal x 30
vertical)
vertical)
16 x 16 dots for each 16 x 16 dots for each
switch
switch
Pressure sensitive
1,000,000 touch operations
60 MB
NS8-V2
NS5-T*-V2
NS5-S*-V2
NS5-M*-V2
768
300
(32 horizontal x 24 (20 horizontal × 15 vertical)
vertical)
16 × 16 dots for each switch
20 x 20 dots for each
switch
20 MB
External Interface specifications
Item
Memory card interface
Expansion interface
Specification
One ATA-Compact Flash interface slot. Used to transfer and store screen data and to store history data.
For Expansion Interface Units Used to install various Interface Units that are currently in development.
Communication specifications
Serial Communication
Item
Port A
Port B
Specification
Conforms to EIA RS-232C.
D-Sub female 9-pin connector
5-V output (250 mA max.) through pin 6 (See note.)
Conforms to EIA RS-232C.
D-Sub female 9-pin connector
5-V output (250 mA max.) through pin 6 (See note.)
Note: The 5-V outputs of serial ports A and B cannot be used at the
same time.
Controller Link (Wired-type) specifications
Item
Baud rate
Transmission path
Specification
2M/1M/500K
Shielded twisted-pair cable (special cable)
Ethernet specifications (NS12-TS01(B) and NS10/8-TV01(B) only
Item
Conformance standards
Specification
Conforms to IEEE 802.3/Ethernet (10Base-T/100Base-T).
Video input specifications
Item
Resolution
Input signal
Number of Camera’s
NS-CA001
320 x 240, 640 x 480, or 800 x 600 dots
composite video NTSC or PAL
4 max.
NS-CA002
Composite, user definable RGB, only full screen
2 x composite video NTSC or PAL, 1 x RGB
3 max.
USB specification
Item
USB rating
Connector
606
Specification
USB1.1
Type A (Host), Type B (Slave)
Human Machine Interfaces
Y201-EN2-03.book Seite 607 Donnerstag, 30. März 2006 1:52 13
Display element specifications
Item
Display
text
Raster font
Font
Rough
name
Standard
Fine
Vector font
(text objects only)
Text
Color
attributes Font style (only when
vector font is specified)
Vertical alignment
Horizontal alignment
Flicker
Objects
Functional
that can
objects
flicker
Fixed objects
Numeral units and scale settings
Alarm/event settings
Display colors
Specification
Displayable characters
Base size
Alphanumeric characters or Japanese katakana
8x8
1 x 1, 1 x 2, 2 x 1, 2 x 2, 3 x 3, 4 x 4, 8 x 8
Alphanumeric characters or Japanese, Chinese (Simpli- 8 x 16
1 x 1, 1 x 2, 2 x 1, 2 x 2, 3 x 3, 4 x 4, 8 x 8
fied, Traditional) or Korean
16 x 16
Alphanumeric characters or Japanese katakana
16 x 32
1 x 1, 1 x 2, 2 x 1, 2 x 2, 3 x 3, 4 x 4, 8 x 8
Japanese kanji
32 x 32
Can be specified in CX-Designer. Font, style, and size can be specified
256 colors (NS5 Monochrome 16 shades of gray)
Bold or italic
Top, center, or bottom
Left-justified, centered, or right-justified
Up to 10 types can be registered.
The flicker speed and flicker range can be set.
Select from 3 types.
The flicker speed and flicker range are fixed.
1,000 max.
5000 max. (with system version 6)
256 colors max. (NS12/10/8 shows BMP in 32,768 colors, NS5 in 4,096 colors, NS5 Monochrome in 16 shades of gray)
CPU Units (1:1 NT Link Connection)
Specifications
With RS-232C connector (9-pin type)
PLC Model name
C-series CQM1
C-series CQM1H
Connect to peripheral port.
C-series CPM1
C-series CPM1A
Connect to RS-232C or peripheral port.
C-series CPM2A
With RS-232C connector (9-pin type)
C-series CPM2C
C-series C200HS
C-series C200HE (-Z)
C-series C200HG (-Z)
C-series C200HX (-Z)
With RS-232C connector (switching/9-pin type) CVM1/CV-series
CVM1 or CV500/
CV1000/CV2000
Note: 1. Use an Adapter Cable (CPM2C-CN111 or CS1W-CN114/118), CPM1-CIF01 RS-232C Adapter, or CPM1-CIF11 RS-422A Adapter to
connect.
2. A C200HW-COM02(-V1), C200HW-COM04(-V1), C200HW-COM05(-V1), or C200HW-COM06(-V1) Communications Board is required.
CPU Units (1:N NT Link Connection)
Model number
Specifications
CS1G-CPU42H/CPU43H/CPU44H/CPU45H
With RS-232C connector (9-pin type)
CS1H-CPU63H/CPU64H/CPU65H/CPU66H/CPU67H
CJ1G-CPU42H/CPU43H/CPU44H/CPU45H (See note 1)
CJ1H-CPU65H/CPU66H (See note 1)
CJ1M-CPU11/CPU12/CPU13/CPU21/CPU22/CPU23 (See note 1)
CQM1H-CPU61/51 with a CQM1H-SCB41 Serial Communications Board
C200HE-CPU32(-Z) (See note 2) /CPU42(-Z)
C200HG-CPU33(-Z) (See note 2) /CPU43(-Z) /CPU53(-Z) (See note 2) /CPU63(-Z)
C200HX-CPU34(-Z) (See note 2) /CPU44(-Z) /CPU54(-Z) (See note 2) /CPU64(-Z) /CPU65-Z/CPU85-Z
PLC Model name
CS-series CS1G
CS-series CS1H
CJ-series CJ1G
CJ-series CJ1H
CJ-series CJ1M
C-series CQM1H
C-series C200HE(-Z)
C-series C200HG(-Z)
C-series C200HX(-Z)
Note: 1. The CJ1W-SCU41 Serial Communications Unit can also be connected.
2. A C200HW-COM02/COM04/COM05/COM06(-V1) Communications Board is required
NS series Advanced Touch Screens
607
Human Machine
Interfaces
Model number
CQM1-CPU41-V1/CPU42-V1/CPU43-V1/CPU44-V1
CQM1H-CPU21/CPU51/CPU61
CPM1-10/[email protected]+CPM1-CIF01
CPM1A-10/20/30/[email protected]@+CPM1-CIF01
CPM2A-30/40/[email protected]@[email protected]+CPM1-CIF01
CPM2C-10/[email protected]@@@@@[email protected](See note 1)
C200HS-CPU21/CPU23/CPU31/CPU33
C200HE-CPU32(-Z) (See note 2) /CPU42(-Z)
C200HG-CPU33(-Z) (See note 2) /CPU43(-Z) /CPU53(-Z) (See note 2) /CPU63(-Z)
C200HX-CPU34(-Z) (See note 2) /CPU44(-Z) /CPU54(-Z) (See note 2) /CPU64(-Z) /CPU65-Z/CPU85-Z
CV500/1000/2000-CPU01-V1
CVM1-CPU01-V2/CPU11-V2/CPU21-V2
Y201-EN2-03.book Seite 608 Donnerstag, 30. März 2006 1:52 13
Standard Models
Name
NS12
Specifications
TFT, 12'', 800 x 600 pixels
Without ethernet
With ethernet
NS10
TFT, 10'', 640 x 480 pixels
Without ethernet
With ethernet
NS8
TFT, 8.4'', 640 x 480 pixels
Without ethernet
With ethernet
NS5-T
TFT, 5.7'', 320 x 240 pixels
Without ethernet
With ethernet
NS5-S
STN color, 5.7'', 320 x 240 pixels
Without ethernet
With ethernet
NS5-M
STN monochrome, 5.7'',
320 x 240 pixels
Without ethernet
With ethernet
NSH5
STN color, 5.7", 320 x 240 pixels
Without Ethernet
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Black
Model
NS12-TS00-V2
NS12-TS00B-V2
NS12-TS01-V2
NS12-TS01B-V2
NS10-TV00-V2
NS10-TV00B-V2
NS10-TV01-V2
NS10-TV01B-V2
NS8-TV00-V2
NS8-TV00B-V2
NS8-TV01-V2
NS8-TV01B-V2
NS5-TQ00-V2
NS5-TQ00B-V2
NS5-TQ01-V2
NS5-TQ01B-V2
NS5-SQ00-V2
NS5-SQ00B-V2
NS5-SQ01-V2
NS5-SQ01B-V2
NS5-MQ00-V2
NS5-MQ00B-V2
NS5-MQ01-V2
NS5-MQ01B-V2
NSH5-SQR00B-V2
Software
Name
NS-series screen design software for windows
Specifications
For NS-series
Windows 95, 98, Me, 2000, XP, NT 4.0 or XP
Model
CX-Designer, included in
CX-ONE
Note: For further information please contact your OMRON representative.
NS series accessories
PT-to-PLC
Connecting Cable
Specifications
Screen transfer cable for DOS/V
USB Host Cable, cable length: 5 m
USB Host Cable, cable length: 2 m
PT connection: 9 pins
PLC connection:9 pins
Accessories
Video input
Cable 1
Length: 2 m
Length: 5 m
Inputs: 4 channels NTSC / PAL
Inputs: 2 channels NTSC b/ PAL, 1 channel RGB
Special cable for the console
Controller link interface unit
RS-422A adapter (50 m)
RS-422A adapter (500 m)
Anti-reflection sheets (5 surface sheets)
Protective anti-reflection covers (5 pack)
Transparent protective covers (5 pack)
Chemical-resistant cover (1 cover)
Memory card
Attachment adapter
Memory card adapter for pc
Battery
Barcode reader (refer to the catalog for details)
1.
NS12/10
NS8
NS5
NS12/10
NS8
NS5
NS12/10
NS8
NS5
NS5
15 MB
30 MB
64 MB
(NT625C/631/631C series to NS12 series)
(NT625C/631/631C series to NS12 series)
(NT620S/620C/600S series to NS8 series)
(NT600M/600G/610G/612G series to NS8 series)
Model
XW2Z-S002
NS-US52 (5 m)
NS-US22 (2 m)
XW2Z-200T
XW2Z-500T
NS-CA001
NS-CA002
F150-VKP (2 m)
F150-VKP (5 m)
NS-CLK21
CJ1W-CIF11
NS-AL002
NS12-KBA04
NS7-KBA04
NT30-KBA04
NS12-KBA05
NS7-KBA05
NT31C-KBA05
NS12-KBA05N
NS7-KBA05N
NT31C-KBA05N
NT30-KBA01
HMC-EF172
HMC-EF372
HMC-EF672
NS12-ATT01
NS12-ATT01B
NS8-ATT01
NS8-ATT02
HMC-AP001
CJ1W-BAT01
V520-RH21-6
Be sure to use cables made by OMRON when connecting NS hardware to a printer. No guarantee of proper operation if other cables are used.
608
Human Machine Interfaces
Y201-EN2-03.book Seite 609 Donnerstag, 30. März 2006 1:52 13
NT21
NT series Touch Screen
Cost effective touch screen terminals to
replace function key units and increase the
flexibility and operation.
Effective display area
117 x 63 mm
High-speed NT Links
Human Machine
Interfaces
Features
Two RS-232C ports
Memory Link
Up to 3,999 screens
Supports Memory Units
Concentrated functionality
Mathematical
functions
31 functional parts
•Recipes
•Alarm lists/histories
•Image library
•Trend graphs
•Analog meters
NT20S/NT31
data compatibility
NT Support Tool
•Shares I/O comment data
with CX-Programmer
•Symbol Manager previews
•Copy image library window data
•Individual editing of grouped parts
NT series Touch Screen
Supports RS-232C/422
Adapter (connector)
Programming Console
function
Barcode Reader
function
609
Y201-EN2-03.book Seite 610 Donnerstag, 30. März 2006 1:52 13
Connectable PLCs for Direct Access
Communications
method
Host link (RS-232C)
C200H
C200HS
CU
1:1 NT Link
---
Memory Link (NTH
protocol)
---
CU/CPU
(Note 1)
CPU
(Note 1)
---
C200HX/HG/
HE(-Z)
CU/CPU
(Note 4)
CPU
(Note 4)
---
C1000H/
C2000H
CU
CS1/CJ1
CV/CVM1 V1 CQM1H
CPM1(A)
SRM1
CU/CPU
CU/CPU
CPU
---
---
CPU
CPU
---
---
---
---
CPU
(Note 5)
CPU
(Note 5)
---
Computer/
SBC
---
---
CPU
CPU
(Note 2)
CPU
(Note 3)
---
CPU: Connected to built-in CPU Unit port, CU: Connected to Communications Unit.
Note: 1. The built-in port can be used on the following CPU Unit: [email protected]/[email protected]
2. The built-in port can be used on the following CPU Unit: CQM1H-CPU21/[email protected]
3. The built-in port can be used on the following CPU Unit: [email protected]
4. Connection is also possible to a Communications Board. Refer to the communications methods for individual models for details.
5. A CPM1-CIF01 RS-232C Adapter must be purchased separately
Specifications
General Specifications
Display Capacity
Item
Power supply voltage
Power consumption
Noise resistance
Vibration resistance
Item
Fixed displays
Fixed character
strings
Graphics
Marks
Ambient operating
temperature
Storage temperature
Ambient operating
humidity
Dimensions
Enclosure ratings
Weight
−20 to 70° C (with no icing)
35% to 85% (with no condensation)(0 to 40°C)
35% to 55% (with no condensation)(40 to 50°C)
190 x 110 x 53.5 mm (W x H x D)
(thickness inside panel: 49.0 mm)
Front panel operating section: Equivalent to IP65F,
NEMA 4.*
0.6 kg max.
Number of screens
Screen types
* Usage may not be possible in places where the unit would be
exposed to oil for long periods.
Specification
A total of 65,535 per
With overlapping screens,
screen
the total is 524,280 per
(Graphics: Continuous
screen
straight lines, rectangles,
circles, polygons, arcs,
sectors)
Numeral displays
256 positions per screen, max. 10-digit disply
(2 words)
Character string dis- 256 positions per screen max.
plays
1,024 display elements for overlapping screens
Graph displays
50 positions per screen, capable of displaying signs
and percentages
Analog meters
50 positions per screen, capable of displaying signs
and percentages
Trend graphs
One frame per screen, 50 items per frame
(8 items max. for data logging)
Broken line graphs One frame per screen, 256 items per frame,
260 points per item
Lamps
256 positions per screen
Image library images 256 positions per screen
Touch switches
256 positions per screen, max. 256 meshes
Numeral settings
256 positions per screen Total of 256 positions for
(numerical keypad)
both numerical and thumbwheel settings
Thumbwheel
26 positions per screen
settings
Character string
256 positions per screen
settings
Temporary inputs
One position per screen
Alarm lists/histories Four groups per screen
Recipes
One position per screen
Normal screens
Display screens registered as normal
Overlapping screens A maximum of eight screens can be displayed
overlapping each other
Windows
Up to three window screens can be displayed
Display history
Order of occurence (1,024 screens max.), order of frescreens
quency (255 times max.)
System startup
Displayed when powering ON (or resetting) the PT,
screen
and when switching to RUN mode
Programming
Emulates PLC programming Console functions,
console screen
capable of being called from RUN mode.
Screen attributes
Buzzer, display history, normal background colors,
backlight mode, local windows
Max. number of reg- 3,999
istered screens
Screen number
0:
No display
1 to 3999: User registered screens
(normal, overlapping, windows)
9000:
System startup screen
9001:
Display history screens, order of occurence
9002:
Display history screens, order of frequency
9020:
Programming console screen
9021 to 9023, 9030: Reserved
9999:
Return to previous screen designation
Screen registration
By transferring screen data from the NT Support Tool
method
to the PT via serial communications
By mounting the Memory Unit and downloading
(automatic/manual transfer) data to the PT
Saving screen data
Flash memory (PT internal image memory)
Display elements
Shock resistance
Specification
24 V DC ±15%
7 W max
Conforms to IEC61000-4-4, Power supply line 2 kV
10 to 57 Hz with 0.075 mm single amplitude, 57 to 150
Hz with 9.8 m/s2 acceleration,
for a total of 60 min. in X, Y, and Z directions.
Peak acceleration 15 G
3 times each in X, Y, and Z directions
0 to 50° C (with no icing)
610
Human Machine Interfaces
Y201-EN2-03.book Seite 611 Donnerstag, 30. März 2006 1:52 13
Display Specifications
NT21 Standard Models
Item
Display Display device
Panel
Number of dots
(resolution)
Effective display
area
Viewing angle
Display color
Service life
Automatic turnOFF
Backlight
Service life
(white cold
cathode tube) Replacement
Product
NT21 Programmable
Terminal
Support
Tool
Cables
Specification
Monochrome STN LCD
260 dots horizontally x 140 dots vertically
117 mm horizontally x 63 mm vertically
Left/right direction: 30°, up/down: 30°
Black & white (with blue mode)
50,000 hours min. (until contrast reduced to 50%)
Can be set to turn OFF in 1 to 255 min or to remain
ON with screen saver
50,000 hours min. (at room temperature, until
brightness is reduced to 50%)
Non-replaceable
Options
Panel Specifications
Item
Touch Number of
panel switches
Input
Threshold force
for operation
Life expectancy
Specification
91
(13 horizontally x 7 vertically)
Pressure-sensitive
1 N max.
Specification
Monochrome STN
Frame color: beige
Frame color: black
Windows 95, 98, ME, NT, 2000 and CD-ROM
XP (Pro)
For screen transfer
For PLC
PT: 9-pin
Cable
connection PLC: 9-pin
length: 2 m
Cable
length: 5 m
PT: 9-pin
Cable
PLC: Mini-peripheral length: 2 m
Reflection Protective
Display area only (5
Sheets
sheets)
Chemical-resistive Cover Silicon cover
Battery
For alarm lists/
histories
Memory Unit
For screen and
system data transfer
RS-232C/422A Adapter
Connector Kit
Model number
NT21-ST121E
NT21-ST121B-E
NT-ZJCAT1-EV4
XW2Z-S002
XW2Z-200T
XW2Z-500T
NT-CN221
NT20M-KBA04
NT20S-KBA01
C500-BAT08
NT-MF161
NS-AL002
XM2S-0911S003
1 million operations min.
External Interface Specifications
Serial port A
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Serial port B
Not Supported
Supported
Supported
Supported
Supported
Supported
Not Supported
Human Machine
Interfaces
Communication method
NT support Tool
PLC Host Link
1:1 NT Link
1:N NT Links
NT Link, PT Programming Console function
SBC/personal computer Memory Links
Barcode Reader
.
Dimensions
178
100 122
53.5
4.5
39 min.
42 max.
Rear panel
110
15.5
28
142
190
Panel thickness: 1.6 to 4.8 mm
Recommended cut-out size:
178.5 +0.5/Ð0 x 100.5 +0.5/Ð0 mm (W x H)
NT series Touch Screen
19.5
52.5
611
Y201-EN2-03.book Seite 612 Donnerstag, 30. März 2006 1:52 13
NT11
NT series Function Key screens
The NT11, the Slim, Low Cost Operation
Terminal that Stands Up Well to Harsh
Environments.
•
•
•
•
Long-lived Backight
Simplified Ladder Programming
Password Screens
Conforms to NEMA4 and IP65
Main features
Withstands Water and Oil
• Use in many demanding ares even with oil and water
The front panel of the terminal withstands water to NEMA4 and IP65
standards, which means that it can be used even in locations where it
may be splashed with water or oil.
Large Keys
• For easy operation by all users
The numeric keys and function keys have been made a generous size
for your convenience. They can be operated even when wearing working gloves.
Entry of Numerical Values
The numeric key pad integrated with the display allows the entry of
numerical values such as temperatures and production quantities.
Printout of Production Status
Data such as the production status and production results can be printed out, leaving a record on paper which can be used as a daily report.
(The NT11S has a printer port. One screen only is printed.)
“Direct Connection” Communication
• Simplifies Ladder Programming
The NT11S supports two communication methods: the "NT link"
(high/low speed), which substantially reduces the size of the program
at the host side, and the "Host Link" direct connection method.
The “NT link” method features a particularly high response speed.
Integral Numeric Key Pad
The display, numeric keys, and function keys are all integrated into the
front panel, which is convenient for designers. The key layout is ergonomically designed for ease of use.
Password Screens for Security
• To limit access to authorized persons only
Password screens cannot be accessed unless the correct password is
entered. This means that the operations that can be performed can be
restricted according to the operator.
Key Titles can be Marked on the Function Key Sheet
Key titles can be marked on the function key sheet in accordance with
the applications of the keys: the sheet can be taken out from the side
face of the terminal. The front panel of the terminal has a water–withstanding construction.
Bar Graphs can be Displayed
Bar graph displays allow the progress of processes to be checked at a
glance. (The bars are oriented horizontally.)
Display History Record Helps in Analysis of Machine
Faults
When the display history record function is set as a screen attribute, the
time, the screen number, and a comment are recorded in the terminal’s
memory every time the relevant screen is displayed. This display
history can be printed by issuing a print instruction from the host, and is
useful for machine fault analysis.
Screen Operations are Easy
Using the support software, screens to be displayed by the terminal can
be created as easily as if using a word proces-sing program. This software can be run on an IBM PC/AT or compatible. It contains the system
program transfer tool that downloads the system program to the flash
ROM.
Main functions
• Fixed displays, numeral display, character display
• Character inversion, flashing, double–width. Character copy, move, delete.
• 8 x 16 dot mark registration (max. 64 marks can be registered)
• Horizontal bar graphs
• Numeral setting
• Password
612
Human Machine Interfaces
Y201-EN2-03.book Seite 613 Donnerstag, 30. März 2006 1:52 13
Easy to Order
The front panel is available in beige or black
Since the communication interface, image memory, and flash ROM that
downloads the system program are incorporated in the NT11 body, placing orders is a simple matter.
Long–life Backlight
Since LEDs are used for the backlight, it is very long–lived and rarely
needs to be changed.
Specifications
General Specifications
Power supply voltage
Allowable power supply voltage range
Power consumption
Noise resistance
Vibration resistance
Shock resistance
Ambient operating temperature
Ambient operating humidity
Operating environment
Storage temperature
Enclosure ratings
Weight
24 V DC ±15%
20.4 to 27.8 V DC (24 V DC –15 %, +10 %)
15 W max.
Common mode (between power supply and panel): 1000 Vp–p
Normal mode: 300 Vp–p
Pulse width: 100 ns to 1 ms Pulse rise time: 1 ns
10 to 57 Hz with 0.75 mm double amplitude and
57 to 150 Hz with 1G acceleration for a total of 30min. in X, Y, and Z directions.
Peak acceleration 15 G 3 times each in X, Y, and Z directions
0 to + 50 °C
35 to 85 % RH (with no condensation)
No corrosive gases.
–20 to +70 °C (with no freezing)
Front panel: Equivalent to IP65, NEMA4
1.0 kg max.
Display/Panel Specifications
Display screen
Dot matrix of STN liquid crystal display panel
Backlight
- Number of dots: 160x64
- LED
- Effective display area: 100 x 40 mm
- Life expectancy: 50,000 hours minimum
- Life expectancy: 50,000 hours minimum
- Automatic turn–off: can be set to turn off in 10 min- View angle (left/right direction): ±20°
utes or 1 hour, or to remain on.
- POWER indicator (Green LED): Lit while power is being supplied.
- RUN indicator (Green LED): Lit during operation
- 22 switches
- Life expectancy: 1 million operations minimum
Indicators
Switch
Display Capacity
Note: Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice.
Display characters
Number of characters
Enlargement function
Display
elements
Screen attributes
Character string displays
Numeral displays
Graph displays
Numeral settings
Display history
Password screen
Menu screen
Screen types
Max. number of registered screens
Screen registration method
Screen saving method
Normal characters (8 16 dots): Alphanumerics and symbols
Marks (8 16 dots): User–defined, 64 max.
displayed Normal–size: 20 horizontally 4 lines vertically max.
Double width
8 positions per screen
8 positions per screen
4 positions per screen
8 positions per screen
Order of frequency, 256 screens
Ensures security: screens for which this attribute is set can only be displayed if the correct password is input.
Four items per screen
Normal screen: Displays screen registered as normal.
250
Transfer screen data created using an IBM PC/AT personal computer to the PT.
Saved to flash memory: 32KB (downloading method)
Special Features
Printing function
Printing of display history data
Printing of daily reports (printing format registered by the users)
Self–test for memory, switches, etc.
Status setting confirmation for communications and other conditions.
Simple communications confirmation
Maintenance functions
.
Ordering Information
Product
Programmable
Terminal
Support Software
Specification
Host link direct connection, Ten–key type (frame color: beige)
NT link method
Ten–key type (frame color: black)
3.5” FD (for IBM PC/AT)
NT series Function Key screens
Model
NT11–SF121-EV1
NT11–SF121B-EV1
NT–ZJCAT1-EV4
613
Human Machine
Interfaces
Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice.
Y201-EN2-03.book Seite 614 Donnerstag, 30. März 2006 1:52 13
Dimensions
203
113
98
7.5
218
38.2
45.3
63.7
22.8
86.2
51
34.2
76
71
614
Human Machine Interfaces
Y201-EN2-03.book Seite 615 Donnerstag, 30. März 2006 1:52 13
NT3S
NT-XS series Touch Screen
A
B
E
D
C
NT-XS series Touch Screen
F
G
AB On the NT3S you can show different kind of bar graphs. Single bar
graphs can be filled in different directions and multiple bar graphs with
legend can easily be created with a simple wizard.
C Up to nine languages can be used in the NT3S. This means you can
for instance make the text buttons variable. This way you can design
one project with different languages so you can use it in different countries.
D You can monitor up to 256 alarms in 16 different groups with the
NT3S. Alarms can be shown with text, time, date and status. Acknowledgement can be prohibited by password.
E Analogue meters can also monitor values of connected devices. You
can set the range, angle, and “colours” to your wish.
F You can create your own buttons and lamps by making use of bitmaps or by choosing one from the library. You can set the “colour”, filling and label.
G Showing and entering data is easy with the NT3S. Data can be
shown in the desired format (HEX, BCD etc.). Entering data is performed with a pop-up keypad.
615
Human Machine
Interfaces
• 4.1“ monochrome STN LCD with LED backlight
(long lifetime)
• Maximum of two universal (RS232/485/422) serial
ports to connect multiple devices with different protocols at the same time
• Drivers for most PLCs, Inverters and Servo Controllers
• Multiple data entry objects per screen with individual
limit setting and math operations
• Support for floating point data
• Wizards for rapid application development of standard bitmapped objects
• Real-time and historical alarms (historical alarms in
RTC models only)
• Trend graph for defined tags (RTC models only)
• Saves recipes data in non-volatile memory
• Windows® based programming software NT-XS for
free!
• IP65 design, CE / cULus Class 1Div. 2 certification
Y201-EN2-03.book Seite 616 Donnerstag, 30. März 2006 1:52 13
A
A
A typical application for the NT3S is a machine where an Omron
PLC and Intelligent Servo Drives are used. The NT3S can be
used to communicate with both the PLC and the Servo Drives.
This means setting parameters, reading and writing variables like
speed, torque, distance and actual position. It is also possible to
move data from the PLC to the Servo Drive (e.g. to change
acceleration times). The NT3S gives you the advantage of being
able to communicate with the drives without using a bus-system,
so a smaller and less expensive PLC can be used.
B
B
You can also use the NT3S to connect Omron Inverters to another
PLC brand. In this solution the NT3S can communicate with the
third party PLC* and at the same time the NT3S can change data
in the Omron Inverters. Inverter settings can be changed directly
from the screen but also from the PLC program. The NT3S acts
as a gateway between the different protocols. This way you can
save a lot of time developing the communication between the PLC
and the Omron Drives.
C
Connecting multiple NT3S terminals to one Omron PLC is a good
solution for long machine lines where local setting or monitoring is
needed. You can connect a maximum of 8 screens to one PLC.
By using the multiple NT3S terminals next to one more advanced
HMI like the Omron NS series, you can have a high functional
solution with local operation possibility against few extra costs.
* Please contact your local Omron representative for a list of available drivers
C
616
Human Machine Interfaces
Y201-EN2-03.book Seite 617 Donnerstag, 30. März 2006 1:52 13
Specifications
Model
Type of display
Dimensions (W x H x D, mm)
Effective display area
Display colour
Communication
RTC
Power supply
Touch panel
Obtained standards
Display graphics
No. of display characters (standard
characters)
No. of registered screens
Screen data capacity (standard)
Internal memory
Printer connection
Backlight life
Multi-vendor support
NT3S-ST126B-E
NT3S-ST124B-E
LCD 4.1 inch, STN, Monochrome display
140 X 77 X 35
98 X 35 mm (4.1 inch)
Green LCD, Monochrome
2x RS232
1x RS2321x RS485/422/232
24V DC +/-15%
Analog Resistive
CE, cULus
Rectangle, Rounded Rectangle, Circle, Oval, Line, Bitmaps
32 characters x 8 lines
NT3S-ST123B-E
NT3S-ST121B-E
2x RS485/422/232
Supported
65000 max. (limited by memory capacity)
120 Kb
1 kWords data memory, 1 kWords retentive, 64 words system memory
Supported
LED, min 50.000 hours
Supports most third party PLCs
Dimensions (mm)
Panel
140.00
Gasket
Human Machine
Interfaces
131.00
77.20
68.00
Mounting
Clamp
Mounting
Screw
Bezel
31.80
Software
Name
NT2S and NT3S support software for windows
Specifications
For all models of these NT-XS series
Model
NT-XS (free downloadable
from our website)
Note: For further information please contact your OMRON representative.
NTXS accesories
Cables for
NT2S-SF121/125 and NT3S
NT2S-SF121/125 and NT3S
NT2S-SF122/SF123/SF126/SF127
NT2S-SF122/SF123/SF126/SF127
NT2S-SF121/125 and NT3S
NT2S-SF122/SF123/SF126/SF127
NT2S-SF121/125 and NT3S
NT2S-SF121/125 and NT3S
NT2S-SF122/SF126
NT-XS series Touch Screen
Specification
peripheral port CPM series except CPM2C, 2 m
peripheral port CPM series except CPM2C, 5 m
peripheral port CPM series except CPM2C, 2 m
peripheral port CPM series except CPM2C, 5 m
mini-peripheral port CJ1/CS1 and CPM2C series, 2 m
mini-peripheral port CJ1/CS1 and CPM2C series, 2 m
Serial Port PLC and NT2S/NT3S,2M
Serial Port PLC and NT2S/NT3S,5M
Serial Port PLC and NT2S/NT3S,2M
Model
NT2S-CN212-V1
NT2S-CN215-V1
NT2S-CN222-V1
NT2S-CN225-V2
NT2S-CN223-V2
NT2S-CN224-V1
NT2S-CN232-V1
NT2S-CN235-V1
NT2S-CN242-V1
617
Y201-EN2-03.book Seite 618 Donnerstag, 30. März 2006 1:52 13
NT2S
NT-XS series Function Key Screens
The NT2S series Terminals are designed
as a human machine interface for simple
control tasks. Their small dimensions and
low installation depths ensure that they
will fit into any machine.
Of the six NT2S types, four can be connected
directly to the peripheral port and two can be
connected to OMRON PLCs via an RS-232C
port.
•
•
•
•
•
•
Easy programming
Small size and installation depth
IP65 protection
Real-time clock
Printer connection
Excellent value for money
Performance Data (Max. Values)
Max. screen pages
NT2S-SF121B-EV2
Yes
109x60x36 mm
56x11 mm
5x7 pixel/character
2/16
6
24 kB for applications
250
NT2S-SF125B-E
Yes
107x107x36
56x11 mm
5x7 pixel/character
2/16
20
24 kB for applications
250
NT2S-SF122B-EV2
Yes
109x60x36 mm
56x11 mm
5x7 pixel/character
2/16
6
24 kB for applications
250
NT2S-SF126B-E
Yes
107x107x36
56x11 mm
5x7 pixel/character
2/16
20
24 kB for applications
250
Number input
Bar graph
Trend/line diagram
Alarm handling
Real-time clock/date
Printer interface
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes (RS-232C)
-
Yes (RS-232C)
-
Yes (peripheral port)
-
Programmable
Terminal size (W,H,D)
Display size
Number of screen pixels
Number of lines/characters
Number of function/control keys
Memory
NT2S-SF123B-EV2
No (PLC controlled)
109x60x36 mm
56x11 mm
5x7 pixel/character
2/16
6
PLC memory is used
NT2S-SF127B-E
No (PLC controlled)
107x107x36
56x11 mm
5x7 pixel/character
2/16
20
PLC memory is used
Yes
Yes
Yes
Depending on PLC
memory
Yes
Yes
-
Depending on PLC
memory
Yes
Yes
-
Yes (peripheral port)
-
Yes (peripheral port)
-
Yes (peripheral port)
-
Communication
Host Link
1:1 NT Link
1:n NT Link
ASCII protocol
618
Human Machine Interfaces
Y201-EN2-03.book Seite 619 Donnerstag, 30. März 2006 1:52 13
System Configuration
Host Link
Data is exchanged quickly between the Control
Terminal and an OMRON PLC using the Host Link
protocol.
The RS-232C communication method can be used.
The following OMRON PLC systems feature the
Host Link protocol:
- CPM1 family
- CPM2 family
- CQM1 family
- CJ1
- CS1
Miniature Peripheral
port
NT2S-SF121B
NT2S-CN223-V2
for CS1,CJ1, CQM1H
CS1
RS232C port
CJ1
RS-232C cable
for CPM1A, CPM2C
(CIF adapter required)
NT2S-SF125B
Peripheral port
CQM1H
CN212-V1/215-V1
for CPM1A, CPM2A
CPM2C
Human Machine
Interfaces
CPM2A
CPM1A
Power supply: 24 VDC, external
Miniature peripheral
port
NT2S-SF122B
NT2S-SF123B
NT2S-CN224-V1
CS1
CJ1
NT2S-SF126B
NT2S-SF127B
CQM1H
CPM2C
Peripheral port
NT2S-CN222-V1
NT2S-CN225-V2
CPM2A
CPM1A
Power supply: from the PLC, via port connection
NT-XS series Function Key Screens
619
Y201-EN2-03.book Seite 620 Donnerstag, 30. März 2006 1:52 13
Product Overview
Model code
Display size (WxHxD)
Number of screen pixels
Number of lines/characters
Number of function/control keys
Memory
Supply voltage
Degree of protection
NT2S-SF121B-EV2 NT2S-SF125B-E
- Programmable using software
- Real-time clock
- Printer port
- PLC connection via RS-232C port
- Supply voltage 24 V
108x60x43 mm
108x108x43 mm
5x7 pixel/character
2/16
2/16
6
20
24 kB Flash memory for applications
24 V DC
24 V DC
IP65F (front side)
NT2S-SF122B-EV2 NT2S-SF126B-E
- Programmable using software
- Printer port
- PLC connection via peripheral port
- Supply voltage connection via peripheral
port
108x60x43 mm
108x108x43 mm
NT2S-SF123B-EV2 NT2S-SF127B-E
- Functions are controlled using the PLC
- PLC connection via peripheral port
- Supply voltage connection via peripheral
port
2/16
6
2/16
2/16
6
20
PLC memory is used
2/16
20
108x60x43 mm
108x108x43 mm
---
Specifications
Model code
Function keys
Key type
Key function
Display elements
Characters
Image colours
Character display attributes
Display specification
Display
Function displays
Display capacity
String display
Numeric display
Bar graph display
Character string input
Alarm list
Time display
Screen page
Number of stored screen pages
Screen page numbers
Storing of screen pages
General
Battery backup
Supply voltage
Power consumption
Immunity
NT2S-SF121B-EV2 NT2S-SF125B-E
NT2S-SF122B-EV2 NT2S-SF126B-E
NT2S-SF123B-EV2 NT2S-SF127B-E
Membrane keyboard
As well as fixed or system functions, functions can be assigned dynamically using software (Softkeys), while global, i.e. screenindependent, keys can also be defined
5x7 pixel/character
Monochrome
Normal, flashing (entire screen)
- LED backlit LCD Module, 2x16 characters, 5x7 pixel/character
- Character size 4.35 mm
- Extended ASCII character set (semi-graphic)
2 status LEDs1, programmable via PLC
Entire display area can be used
Entire display area can be used
Entire display area can be used
Either by output from Controller real-time From Controller
clock or output from Terminal's integrated
real-time clock
Max. 250
1..250
Transfer of data from a PC to the Terminal
All programming in the PLC
Data backup in EEPROM
24 V DC ± 10%
via PLC
approx. 1.5 W
Between power supply and panel: 1700 Vss
Normal:
480 Vss
Pilse width
100 ns..1 µs
Pulse rise time
1 ns
10..61.2 Hz with 0.1 mm amplitude
61.2..150 Hz with an acceleration of 1.5 g in X, Y and Z directions 4 times for 8 minutes each
147 m/s², 3x in X, Y and Z directions
0 °C..50 °C
35%..85%
No corrosive gases
-20 °C..60 °C
Front side: IP65F, Rear side: IP20
CE, cULus Class 1 Div. 2
150 g
230 g
135 g
205 g
130 g
Vibration resistance
(in operation)
Shock resistance (in operation)
Ambient temperature
Ambient humidity
Operating environment
Storage temperature
Degree of protection
Approvals
Weight
Host Link Direct communication
Communication method
RS-232C or Peripheral port
Peripheral port
Communication protocol
C series SYSWAY (1:1)
Communication settings
Start/stop synchronisation Communication speed: 9600 bps
Data length:
7 bits
Stop bit:
2 bits
Parity:
even
Connection
1 x 9-pin D-Sub female for PLC
1 x 9-pin D-Sub male for PLC
1 x 9-pin D-Sub female for PC/Printer,
1 x 9-pin D-Sub female for PC/Printer
SW download/printer
Number of devices
1
Printer
Communication method
ASCII protocol printer
Connection
Serial RS-232C port
200 g
1x9-pin D-sub male for PLC
No
No
1. The NT2S-SF125/126/127B-E do not have status LEDs
620
Human Machine Interfaces
Y201-EN2-03.book Seite 621 Donnerstag, 30. März 2006 1:52 13
Programming and Accessories
Software
Name
NT2S and NT3S support software for windows
Specifications
For all models of these NT-XS series
Model
NT-XS (free downloadable
from our website)
Note: For further information please contact your OMRON representative.
NTXS accesories
Cables for
NT2S-SF121/125 and NT3S
NT2S-SF121/125 and NT3S
NT2S-SF122/SF123/SF126/SF127
NT2S-SF122/SF123/SF126/SF127
NT2S-SF121/125 and NT3S
NT2S-SF122/SF123/SF126/SF127
NT2S-SF121/125 and NT3S
NT2S-SF121/125 and NT3S
NT2S-SF122/SF126
Specification
peripheral port CPM series except CPM2C, 2 m
peripheral port CPM series except CPM2C, 5 m
peripheral port CPM series except CPM2C, 2 m
peripheral port CPM series except CPM2C, 5 m
mini-peripheral port CJ1/CS1 and CPM2C series, 2 m
mini-peripheral port CJ1/CS1 and CPM2C series, 2 m
Serial Port PLC and NT2S/NT3S,2M
Serial Port PLC and NT2S/NT3S,5M
Serial Port PLC and NT2S/NT3S,2M
Model
NT2S-CN212-V1
NT2S-CN215-V1
NT2S-CN222-V1
NT2S-CN225-V2
NT2S-CN223-V2
NT2S-CN224-V1
NT2S-CN232-V1
NT2S-CN235-V1
NT2S-CN242-V1
Dimensions (mm)
NT2S-SF121B-EV2
NT2S-SF122B-EV2
NT2S-SF123B-EV2
60
Human Machine
Interfaces
43
27
109
92
NT2S-SF125B-E
NT2S-SF126B-E
NT2S-SF127B-E
107
107
93
27
92
NT-XS series Function Key Screens
621
Y201-EN2-03.book Seite 622 Donnerstag, 30. März 2006 1:52 13
NT-AL001
RS-232C/RS-422A Adapter
The NT-AL001 converts signals between
RS-232C and RS-422A.
Use the NT-AL001 to connect 1:N NT Link
communications, to connect to multivendor
communications, or anytime signal
conversion is required.
Specifications
Dimensions
General Specifications
Item
Model number
Ambient operating temperature
Ambient operating humidity
Rated power supply voltage
Rated power supply current
Surge current
Insulation resistance
Specification
NT-AL001
0 to 55° C
RS-422A terminals
53.5
110
10% to 90% (with no condensation)
+5 V ±10% (supplied from pin 6 of RS-232C connector)
150 mA max.
RS-232C connector
OMRON NT-AL001
4
74.5
100.2
105 max.
0.8 mA max.
20 MΩ min. (at 500 V DC) between RS-422A signal
lines and functional ground terminal
Dielectric strength
1,500 V AC between RS-422A signal lines and functional ground terminal for 1 min, leakage current: 10
mA max.
Operating environment No corrosive gases
Ambient storage temper- −20 to 75° C
ature
Vibration resistance
Conforms to JISC 0911, 80 min each in X, Y, and Z
directions
Shock resistance
Conforms to JISC 0912, 15G for 3 times each in X, Y,
and Z directions
Weight
200 g
(30)
45
30
(Unit: mm)
30 x 114 x 100.2 mm (W x H x D) with RS-422A terminal cover removed.
30 x 114 x 119.5 mm (W x H x D) with RS-422A terminal cover in place.
RS-232C Interface
Item
Baud rate
Transmission distance
Connector
Specification
64 kbps max.
2 m max.
D-Sub, 9-pin connector (female)
RS-422A Interface
Item
Baud rate
Transmission distance
Terminals
622
Specification
64 kbps max. (depends on RS-232C baud rate)
500 m max.
8-terminal removable terminal block, M3.0 terminals
Human Machine Interfaces
Y201-EN2-03.book Seite 623 Donnerstag, 30. März 2006 1:52 13
Ordering Information
HMI
Name
NS12
Specifications
TFT, 12'', 800 x 600 pixels
Without ethernet
With ethernet
NS10
TFT, 10'', 640 x 480 pixels
Without ethernet
With ethernet
NS8
TFT, 8.4'', 640 x 480 pixels
Without ethernet
With ethernet
NS5-T
TFT, 5.7'', 320 x 240 pixels
Without ethernet
With ethernet
NS5-S
STN color, 5.7'', 320 x 240 pixels
Without ethernet
With ethernet
NS5-M
STN monochrome, 5.7'',
320 x 240 pixels
Without ethernet
With ethernet
NSH5
STN color, 5.7", 320 x 240 pixels
Without Ethernet
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Black
Model
NS12-TS00-V2
NS12-TS00B-V2
NS12-TS01-V2
NS12-TS01B-V2
NS10-TV00-V2
NS10-TV00B-V2
NS10-TV01-V2
NS10-TV01B-V2
NS8-TV00-V2
NS8-TV00B-V2
NS8-TV01-V2
NS8-TV01B-V2
NS5-TQ00-V2
NS5-TQ00B-V2
NS5-TQ01-V2
NS5-TQ01B-V2
NS5-SQ00-V2
NS5-SQ00B-V2
NS5-SQ01-V2
NS5-SQ01B-V2
NS5-MQ00-V2
NS5-MQ00B-V2
NS5-MQ01-V2
NS5-MQ01B-V2
NSH5-SQR00B-V2
Frame color: Beige
Frame color: Black
Model
NT21-ST121-E
NT21-ST121B-E
NT11–SF121-EV1
NT11–SF121B-EV1
Human Machine
Interfaces
NS series
NT series
Name
NT21
Specifications
STN monochrome
NT11
STN monochrome
Frame color: Beige
Frame color: Black
Ten-key type
Specifications
STN monochrome
Programmable
NT-XS series
Name
NT2S
PLC controlled
Programmable
NT3S
STN monochrome
PLC controlled
Programmable
6-key type,
Frame color: Black
20-key type,
Frame color: Black
2 x RS-232/CMOS, No RTC,
No RS485
RS-232/CMOS on one port,
RS-232/CMOS/485/422 on
second port, No RTC
RS-232/CMOS on one port,
RS-232/CMOS/485/422 on
second port with RTC
RS-232/CMOS/485/422 on
both ports with RTC
Model
NT2S-SF121B-EV2
NT2S-SF122B-EV2
NT2S-SF123B-EV2
NT2S-SF125B-E
NT2S-SF126B-E
NT2S-SF127B-E
NT3S-ST126B-E
NT3S-ST124B-E
NT3S-ST123B-E
NT3S-ST121B-E
623
Y201-EN2-03.book Seite 624 Donnerstag, 30. März 2006 1:52 13
Support Software
NS series PTs
Name
NS-series Screen Design Software for Windows
Cable to transfer screens
Specifications
For NS-series PTs
Windows 95, 98, Me, 2000, XP, NT 4.0 or XP
IBM PC/AT or compatible
Model
NS-NSDC1
included in CX-One
XW2Z-S002
Specifications
For NT-series PTs
Windows 95, 98, Me, 2000 or NT 4.0
For NT31, NT31C, NT631, or NT631C
To print hardcopies of screens
For all models of these NT-XS series
Model
NT-Shell
NT(-XS) series PTs
Name
NT-series Support Software for Windows
Memory Unit to transfer screens
Printer cable for NT Series
NT2S and NT3S support software for Windows
NT-MF261
NT-CNT121
NT-XS (free downloadable
from our website)
Options
NS series accessories
PT-to-PLC
Connecting Cable
Specifications
Screen transfer cable for DOS/V
USB Host Cable, cable length: 5 m
USB Host Cable, cable length: 2 m
PT connection: 9 pins
PLC connection:9 pins
Accessories
Video input
Cable 1
Length: 2 m
Length: 5 m
Inputs: 4 channels NTSC / PAL
Inputs: 2 channels NTSC b/ PAL, 1 channel RGB
Special cable for the console
Controller link interface unit
RS-422A adapter (50 m)
RS-422A adapter (500 m)
Anti-reflection sheets (5 surface sheets)
Protective anti-reflection covers (5 pack)
Transparent protective covers (5 pack)
Chemical-resistant cover (1 cover)
Memory card
Attachment adapter
NS12/10
NS8
NS5
NS12/10
NS8
NS5
NS12/10
NS8
NS5
NS5
15 MB
30 MB
64 MB
(NT625C/631/631C series to NS12 series)
(NT625C/631/631C series to NS12 series)
(NT620S/620C/600S series to NS8 series)
(NT600M/600G/610G/612G series to NS8 series)
Memory card adapter for pc
Battery
Barcode reader (refer to the catalog for details)
1
Model
XW2Z-S002
NS-US52 (5 m)
NS-US22 (2 m)
XW2Z-200T
XW2Z-500T
NS-CA001
NS-CA002
F150-VKP (2 m)
F150-VKP (5 m)
NS-CLK21
CJ1W-CIF11
NS-AL002
NS12-KBA04
NS7-KBA04
NT30-KBA04
NS12-KBA05
NS7-KBA05
NT31C-KBA05
NS12-KBA05N
NS7-KBA05N
NT31C-KBA05N
NT30-KBA01
HMC-EF172
HMC-EF372
HMC-EF672
NS12-ATT01
NS12-ATT01B
NS8-ATT01
NS8-ATT02
HMC-AP001
CJ1W-BAT01
V520-RH21-6
Be sure to use cables made by OMRON when connecting NS hardware to a printer. No guarantee of proper operation if other cables are used.
NT series accessories
Product
Cables
Options
624
Specification
For screen transfer
For PLC connection
PT: 9-pin
PLC: 9-pin
PT: 9-pin
PLC: Mini-peripheral
Reflection Protective Sheets
Chemical-resistive Cover
Battery
Memory Unit
RS-232C/422A Adapter
Connector Kit
Cable length: 2 m
Cable length: 5 m
Cable length: 2 m
Display area only (5 sheets)
Silicon cover
For alarm lists/histories
For screen and system data transfer
Model number
XW2Z-S002
XW2Z-200T
XW2Z-500T
NT-CN221
NT20M-KBA04
NT20S-KBA01
C500-BAT08
NT-MF161
NS-AL002
XM2S-0911-S003
Human Machine Interfaces
Y201-EN2-03.book Seite 625 Donnerstag, 30. März 2006 1:52 13
NTXS accesories
Specification
peripheral port CPM series except CPM2C, 2 m
peripheral port CPM series except CPM2C, 5 m
peripheral port CPM series except CPM2C, 2 m
peripheral port CPM series except CPM2C, 5 m
mini-peripheral port CJ1/CS1 and CPM2C series, 2 m
mini-peripheral port CJ1/CS1 and CPM2C series, 2 m
Serial Port PLC and NT2S/NT3S,2M
Serial Port PLC and NT2S/NT3S,5M
Serial Port PLC and NT2S/NT3S,2M
Model
NT2S-CN212-V1
NT2S-CN215-V1
NT2S-CN222-V1
NT2S-CN225-V2
NT2S-CN223-V2
NT2S-CN224-V1
NT2S-CN232-V1
NT2S-CN235-V1
NT2S-CN242-V1
Human Machine
Interfaces
Cables for
NT2S-SF121/125 and NT3S
NT2S-SF121/125 and NT3S
NT2S-SF122/SF123/SF126/SF127
NT2S-SF122/SF123/SF126/SF127
NT2S-SF121/125 and NT3S
NT2S-SF122/SF123/SF126/SF127
NT2S-SF121/125 and NT3S
NT2S-SF121/125 and NT3S
NT2S-SF122/SF126
625
Y201-EN2-03.book Seite 626 Donnerstag, 30. März 2006 1:52 13
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. V04E-EN-03A
626
In the interest of product improvement, specifications are subject to change without notice.
Human Machine Interfaces
Below is a list of articles with direct links to our shop Electric Automation Network where you
can see:
• Quote per purchase volume in real time.
• Online documentation and datasheets of all products.
• Estimated delivery time enquiry in real time.
• Logistics systems for the shipment of materials almost anywhere in the world.
• Purchasing management, order record and tracking of shipments.
To access the product, click on the green button.
Product
Code
Reference
Product link
Operator Interface, NS Series - TFT 12.1 "Color (Beige)
204265
NS12-TS00-V2
Buy on EAN
Operator Interface, NS Series - TFT 12.1 "Color (Black)
204266
NS12-TS00BV2
Buy on EAN
Operator Interface, NS Series - TFT 12.1 "Ethernet Color
(Beige)
204267
NS12-TS01-V2
Buy on EAN
Operator Interface, NS Series - TFT 8.4 "Color (Beige)
209576
NS8-TV00-V2
Buy on EAN
Operator Interface, NS Series - TFT 8.4 "Color (Black)
209577
NS8-TV00B-V2
Buy on EAN
Operator Interface, NS Series - TFT 8.4 "Color Ethernet
(Beige)
209578
NS8-TV01-V2
Buy on EAN
Operator Interface, NS Series - TFT 10.4 "Color (Beige)
209580
NS10-TV00-V2
Buy on EAN
Operator Interface, NS Series - TFT 10.4 "Color (Black)
209581
NS10-TV00BV2
Buy on EAN
Operator Interface, NS Series - TFT 10.4 "Ethernet Color
(Beige)
209582
NS10-TV01-V2
Buy on EAN
Operator Interface, Set of 5 protective covers
(transparent) for 8 "
180449
NS7-KBA05N
Buy on EAN
Control system, CPU 5120 E / S 20KW 64kW RS232C Data
135643
CS1H-CPU63H
Buy on EAN
Interface for Operator, Cable 2m NT2S-SF121/SF125/
NT3S ProCon
182425
NT2S-CN212V1
Buy on EAN
Interface for Operator, Cable 5m NT2S-SF121/SF125/
NT3S ProCon
182426
NT2S-CN215V1
Buy on EAN
Interface for Operator, Cable 2m NT2S-SF121/SF125/
NT3S DDK
182427
NT2S-CN223V2
Buy on EAN
Cable, 5m, for connecting NT2S-SF122/123/126/127 HMI
to CPM1(A)/CPM2A peripheral port
182428
NT2S-CN225V2
Buy on EAN
Operator Interface, Set of 5 antireflective templates for 8
"
144870
NS7-KBA04
Buy on EAN
Interface for Operator, Cable 2m NT2SSF122/123/126/127 ProCon
139373
NT2S-CN222V1
Buy on EAN
Operator Interface, 2x16 LCD Keypad No programmable
(Black)
113752
NT2S-SF127BE
Buy on EAN
Operator Interface, Cable NT2S-122/126 serial port PLC
224098
NT2S-CN242V1
Buy on EAN
Operator Interface, Serial Port PLC (included CP1H) to
NT2S-SF121 / 125 and NT3S 2 meters
224096
NT2S-CN232V1
Buy on EAN
Operator Interface, Housing Black + Connector 9 Pin
Male
107858
XM2S-0911S003
Buy on EAN
Operator interface, LCD 2x16 6 Keys No Programmable
(Black)
143760
NT2S-SF123BEV2
Buy on EAN
Operator interface, RS232 to RS422 converter for NS
(500 m) (Not isolated)
113738
NS-AL002
Buy on EAN
Temperature Control Panel, master Base 24 pins
128536
E5ZNSCT24S-500
Buy on EAN
Operator Interface, 2x16 LCD Keypad RTC (Black)
113750
NT2S-SF125BE
Buy on EAN
Operator Interface, 2x16 LCD Keypad (Black)
113751
NT2S-SF126BE
Buy on EAN
Operator Interface, ControllerLink card terminal NS10 /
12/15
113739
NS-CLK21
Buy on EAN
Operator Interface, Set of 5 antireflective 10/12
templates "
113736
NS12-KBA04
Buy on EAN
Operator Interface, Set of 5 protective covers 10/12 "
113737
NS12-KBA05
Buy on EAN
Control system, CPU 160 E / S 5Kpasos 32KW
184018
CJ1M-CPU11
Buy on EAN
Control system, CPU 960 E / S data 10KW 64kW
135641
CS1G-CPU42H
Buy on EAN
Operator interface, video input card for NS8 / 10/12/15, 2
channels + RGB
180451
NS-CA002
Buy on EAN
Interface for Operator, Cable 2m NT2SSF122/123/126/127 DDK
155506
NT2S-CN224V1
Buy on EAN
Operator Interface, Mounting adapter for NS8 terminal
NT600S / 620S / 620C
229600
NS8-ATT01
Buy on EAN
Operator interface, LCD 2x16 6 Keys (Black)
113749
NT2S-SF122BEV2
Buy on EAN
Operator interface, LCD 2x16 6 Keys RTC (Black)
113748
NT2S-SF121BEV2
Buy on EAN
Operator interface, video input card for NS8 / 10/12, 4
Channels NTSC / PAL
147027
NS-CA001
Buy on EAN
Operator Interface, Set of 5 protective covers for 8 "
147028
NS7-KBA05
Buy on EAN
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement