PRASAR BHARATI (Broadcasting Corporation of

PRASAR BHARATI (Broadcasting Corporation of
Page 1 of 118 PRASAR BHARATI
(Broadcasting Corporation of India)
Directorate General Doordarshan
Doordarshan Bhawan, Copernicus Marg
New Delhi - 110001
Specification No: DG:DD/TxD/HPT/SITC J&K Projects/E-V/2010
Dated 14.09.2010
Specifications for SITC of Two Nos. of 5kW fully Solid State UHF Analog TV
Transmitters alongwith Station Items to be installed at
Rajouri (AIR FM site) in J & K
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 2 of 118 TABLE OF CONTENTS
Sr.
DD Specs Para
No.
No.
Items Description
No.
1. 1
Introduction
2. 2
System configuration
3. 3
4. 4
The Scope of the Supply, Installation, Testing
and Commissioning (SITC) Work
Exciters
5. 5
Power amplifier system
6. 6
Cooling system
7. 7
Upgradability to DVB-T2 Transmitter
8. 8
9. 9
Technical specifications for one 5 kW Analog
TV Transmitter System
Pre-bid Conference
10. 10.
General Requirements for completing the offer
11. 11.
Information to be furnished by successful
bidder
12. 12.
Inspection
13. 13
Installation, Testing and Commissioning
14. 14.
Bill of Material
15. 15.
Additional Points for Rajouri Site
DGDD/TxD/5kWHPT Specs/J&K/2010 Page
Page 3 of 118 16. 16.
Compliance Statement
17. Annexure IA
Suggestive BOM for 2 Nos. Transmitter systems
18. Annexure IB
Suggestive BOM for common items of the two
transmitters
Specifications of 50 kVA AVR
19. Annexure I-1
20. Annexure I-2
Specifications of 10kW Broadcast Power
Monitor (Through line Power meter)
21. Annexure I-3
Specifications of indoor coaxial lines etc.
22. Annexure I-4
Specifications of input, monitoring equipment
and racks
Specifications of standard 19” rack
23. Annexure I-4-I
24. Annexure I-4-II
25. Annexure I-4-III
Specifications of video equalizing distribution
amplifier
Specifications of video audio switcher
26. Annexure I-4-IV
Specifications of Audio Jack Panel-(N/C) 2x24
27. Annexure I-4-V
Specification of video jack panels
28. Annexure I-4-VI
30. Annexure I-4-VIII
Specifications of audio stereo monitoring
amplifier 8 W
Specifications of audio distribution amplifier
with suitable frame and redundant power
supply and extender card
Specifications for audio processor
31. Annexure I-5
Specifications of Monitoring Equipment
32. Annexure I-5-I
Specifications of Waveform Monitor
33. Annexure I-5-II
Specifications of VU Meter
29. Annexure I-4-VII
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 4 of 118 34. Annexure I-6
Specifications of Installation Materials
35. Annexure I-7
36. Annexure I-8
Specifications of computer system with 1 kVA
UPS and Laserjet printer
Specifications of 10 kW dummy load
37. Annexure I-9
Specifications of measuring equipment
38. Annexure I-9-I
Specifications of colour test pattern & tone
generator
Specifications of TV analyser/demodulator
39. Annexure I-9-II
40. Annexure I-9-III
41. Annexure I-10
42. Annexure I-10-I
43. Annexure I-10-II
44. Annexure I-11
45. Annexure I-11-I
46. Annexure I-11-II
47. Annexure I-11-III
48. Annexure I-11-IV
Specification of 2 channel 100 MHz
oscilloscope
Misc items for monitoring and maintenance
Specifications of RF step attenuator (0 – 110
dB)
Specifications of RF fixed attenuator 3 db, 6 db,
12 dB (N type)
Antenna system
Specifications of 10 kW, band IV/V UHF
superturnstile, Omni-directional, broadband
antenna system
Specifications for Strengthening/Modification of
Existing 50mtr. AIR FM Steel Tower:
Specifications of automatic dehydrator system
49. Annexure I-12
Specifications of 2x5 kW, 2 Channel Constant
Impedance UHF Combiner
Specifications of 7 port patch panel
50. Annexure I-13
Specifications of 3⅛” / 4” RF feeder cable
51. Annexure I-14
C band/Ku band satellite receive equipment
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 5 of 118 52. Annexure I-14-I
53. Annexure I-14-II
Specifications of professional IRD for Cband/Ku-band
Specification for the motorized feed of C- band
54. Annexure I-14-III
Specifications for cables & connectors
55. Annexure I-14-IV
57. Annexure I-14-VI
Specifications for parabolic dish antenna, solid
type, 2.4 m (Dia)
Specifications for parabolic dish antenna, 6.2 m
(Dia) with de- icing kit.
Specifications for the digital LNBC in c band
58. Annexure I-14-VII
Specification for the digital LNBC in Ku band
56. Annexure I-14-V
59. Annexure I-15
60. Annexure I-16
61. Annexure I-17
Specifications For 80kVA (1+1) Stand Alone,
Self Contained, Water Cooled Silent Type
Diesel Generator Set
Specifications of 60 kVA 3 input 3 phase output
UPS system for TV transmitters
Specification of container/shelter for housing 2
Nos. DD transmitters and power supply
equipment
62. Annexure I-18
Specifications of Audio Analyser
63. Annexure I-19
Specifications of Amplispeaker
64. Annexure I-20
Specifications of RF Power meter with sensors
65. Annexure II
Suggestive block diagram for 2 Nos. 5 kW TV
transmitters setup at Rajouri site
Details of 7 port patch panel - Schematic
66. Annexure III
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 6 of 118 Specification of SITC of 5kW fully Solid State UHF Analog TV Transmitters
alongwith Station Items and Antenna System, RF Feeder Cable to be
installed at Rajouri (AIR FM site) in J & K.
1.
Introduction:
1.1. Doordarshan (DD) intends to install, on SITC (Supply, Installation, Testing and
Commissioning) basis at Rajouri (J & K) in the premises of AIR FM Transmitter,
two Solid State 5KW UHF Analog TV Transmitters, (Digital upgradable to DVBT2 for future use) with dual exciter system. Two 5kW, UHF TV transmitters are
required separately for transmitting two separate program services namely DD
National and DD News. These transmitters shall be based on latest technology
and have provision for remote monitoring, remote operation and remote Control.
The transmitters should be rugged, reliable, and stable in operation under very
cold to hot, humid and dusty environmental conditions. Specifications of the
transmitters are given in this document. All equipment and items of SITC as per
DD specification should be used for 24x7 continuous operation. The Transmitters
shall be supplied along with all the items as per the specifications and items listed
in suggestive BOM. Transmitter output should be 3⅛” EIA unflange copper. In
case of Aluminium, suitable coupling to connect the output with the Copper rigid
line should be supplied to avoid thermocouple effect.
1.2. The TV transmitters are to be supplied as “complete system” including input and
monitoring equipment, cooling system, UPS, DG sets, AVR, surge suppressors,
interconnecting cables, all installation materials and measuring equipment etc.
which are to be installed on SITC basis.
1.3. Annexure-IA and IB are the suggestive Bills of Material of 5kW, UHF Band
IV/V, Analog TV Transmitter System. Any other item/equipment, which is
essential for the completeness of the system on SITC basis, should also be
included in the offer. It should be ensured by the bidder that the system is
complete in all respects for installation, testing and commissioning at site.
1.4. The output of the two 5kW transmitters will be combined and to be fed to single
3⅛”/4” Dia. R.F. Feeder Cable via seven port patch panel to the single 10KW,
UHF, Superturnstile Antenna system at Rajouri. Suggestive Schematic is given in
Annexure III.
1.5. A detailed block schematic diagram for the whole TV transmitter system with all
its constituent items should be provided with the offer along with the block
schematic of the antenna system.
1.6. The transmitter system must confirm to the latest international standards of safety
and EMC. The conformance to such standards (indicating Standard’s name &
Number) must be stated in compliance statement.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 7 of 118 1.7. Channel frequencies are:
1.7.1. DD National: Ch#32(.) PAL-G (558 to 556 MHz)
1.7.2. DD News: Ch#34(.) PAL-G (574 to 582 MHz)
1.8 Local / remote Monitoring and control Facility: Each Transmitter system is
required to be operated and controlled manually as well as from Remote
location. It should therefore have all provisions of local display, keypad, panels
etc. for local operation, monitoring and control. All essential parameters and
working status of modules should also be available locally. Detailed information on
the parameters and features available for local monitoring and Control of the
transmitter is to be submitted with the offer. The Control/operation/monitoring
Software would run on normal PC with Windows platform. The transmitter system
shall have Control/operation/monitoring of the parameters locally as well as at
remote-location by Personal Computers through web interface. The transmitter
should have a “WEB”GUI interface using TCP/IP. All transmitter functions,
Control & monitoring shall be provided via the remote “WEB” GUI interface. Full
detailed description with diagrams; block schematic etc must be attached with the
offer. This is mandatory requirement.
1.8.1 Remotely Monitorable parameters: Following parameters are to be made
available for monitoring on the PC at the remote location as well as on local
PC. In addition to these, individual parameters are to be monitored within the
units. Details about all the individual screens may be provided with the offer.
a) A/C mains.
b) Transmitter RF Forward Power in KW.
c) Transmitter RF reflected Power in watts
d) DC Voltage/Current of SMPS of PA
e) Alarms for PA’s VSWR, Temperature, overdrive, over current, over
voltage.
f) Individual Unit faults and indications
g) Exciter output level
h) Exciter alarm
i) Any other parameter which the manufacturer thinks essential for proper
functioning of a remote Controlled HPT.
1.8.2 Remotely Controllable parameters:
DD 1 Transmitter ON/OFF.
a)
b)
DD News Transmitter ON/OFF.
c)
Both
the
transmitters
should
be
remotely
monitorable/operable/controllable independently as they shall be carrying different
programme channels.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 8 of 118 1.9 Input, Monitoring and Measuring Equipment Rack: The equipment like IRD,
10x2 Audio-Video switcher, Waveform monitor, Colour Pattern Generator, and
monitoring amplifier etc. should be installed in standard 19” wired rack(s). A
Suggestive Schematic is given in Annexure II.
2 System configuration: The monitoring system of both transmitters shall have LCD
display. Control circuits should be microprocessor based. Mimic RF flow diagram
should be provided for diagnostic and trouble shooting of transmitter system.
3 The scope of the Supply, Installation, Testing and Commissioning (SITC) work
includes the following:
3.1 SITC of 2 Nos. of 5 kW UHF Transmitters along with Input, Monitoring and
Measuring equipment complete in all respects to be installed in a air-conditioned
container (weather proof container having heating as well cooling facility).
3.2
SITC of Antenna System, RF feeder Cable, Combiner, Dehydrator and 7 Port
Patch Panel.
3.3 SITC of Power Supply equipment including DG sets, UPS systems, AVR, AMF
Panel etc.
3.4 SITC for Suitable Strengthening of existing 50 M AIR FM Tower at Rajouri as
required, before installation of Antenna System and RF Feeder Cable on the tower.
3.5 SITC of power supply system.
3.6 SITC of Satellite receive equipment (PDAs, feeds, LNBCs, IRDs, Cables)
including foundation of 6.2 M PDAs.
3.7 Design and SITC (DSITC) of container as per DD specifications with sloping roof
for Transmitter and Power Supply Equipment.
4 Exciters: Exciters shall have their own DC power supply and there shall be digital
signal processing (DSP) in the exciter. It shall have facility for auto correction of non
linear distortions. Exciters shall function in (1+1) configuration with necessary
hardware and software control for auto changeover with suitable display system. A
detailed circuit diagram must be attached with the offer to confirm the availability of
DSP in the exciter.
5 Power Amplifier System:
5.1 Each power amplifier(PA) must have its own DC power supply unit, All PAs must
be inter changeable at any position and to be use at any channel in the specified
band of operation without change of any hardware/software in the transmitters of
same make and model. All PAs shall have protection against high SWR, Over
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 9 of 118 current, Over voltage and Over temperature. Visual indication for above
protections should be available in each power amplifier, LDMOSFET devices shall
be used in all power amplifiers. The datasheet of the LDMOS must be attached
with the offer.
5.2 All PAs should be hot pluggable, Transmitter shall be capable to remain ON AIR
with reduced power output without any break in service even if a number of
PA/PAs have failed. All PAs shall be fully broadband for operation in UHF Band
IV/V i.e.470MHz to 862MHz.
6 Cooling system: The transmitter with liquid cooling system only is acceptable.
6.1 To make the system fully reliable, all possible redundancy must be incorporated in
to the cooling system.
6.2 Full details of the cooling system with block schematic including details of coolant
must be provided with the offer.
6.3 All materials, piping, tools, liquid coolant up to double capacity required for the
transmitters, essential spares must be supplied along with the transmitter (one full
quantity of coolant filled and one spare quantity of the coolant for each of the
transmitters is to be provided).
6.4 Connectors of amplifiers etc shall be of self locking type so that no liquid escapes
during removal or replacement of PA/Power supplies.
6.5 Outside temperatures may vary from -10o C to +50o C. Heat exchanger and liquid
coolant used must be compliant with these temperature variations. There should be
special provisions for satisfactory working of Heat exchangers to transfer the heat
at very low temperature i.e., -10o C outside environment.
7 Upgradability to DVB-T2 Transmitter:
7.1 The offered analog transmitter should be able to be used as DTT (DVB-T2)
(Digital terrestrial transmitter adopting DVB-T2 standard) Transmitter in future
with the minimum possible changes.
7.2 The offered analog transmitter should have low level diplexing (Common
Amplification). Full technical details for upgradation of quoted anlog transmitter as
DTT (DVB-T2) transmitter along with the financial requirement for the
upgradation must be furnished with the offer separately without which tender will
be considered incomplete & is liable to be rejected. This upgradation cost will
however not be counted for deciding the lowest bidder. Break detail of the items
must be provided in the BOM as optional items.
7.3 The broad specifications of upgraded analog transmitter to DVB-T2 DTT
Transmitter are given below:
7.4 Broad Specifications of DVB-T2 Transmitter:
System Parameters
7.4.1
Transmitter Power output
To be specified by the Transmitter OEM
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 10 of 118 7.4.2
7.4.3
7.4.4
7.4.5
(after output BPF (DVB-T2
critical mask))
Frequency Range
7.4.6
Bandwidth
TV standard
Harmonic level (for all
harmonics)
Spurious emission
7.4.7
Modulation
7.4.8
Inter modulation products
(before filter)
Crest Factor/PAPR
Equivalent Noise
Degradation (END)
MER at the input of critical
mask
Shoulder Level (before filter)
Shoulder Level (after critical
filter)
7.4.9
7.4.10
7.4.11
7.4.12
7.4.13
8.
Any assigned channel between 470 MHz to
862 MHz (UHF Band IV/V)
8 MHz
DVB-T2, compliant to EN 302 755
60 dB below carrier level or better
60 dB below carrier level or better
Coded
orthogonal
frequency
division
multiplex (COFDM) having all modes of
modulation and parameter options as per EN
302 755
<-35dB (with pre correction) at ±4.2MHz
13 dB Max
1 dB Max
> 33 dB
< - 35 dB
According to DVB-T2 critical mask.
Necessary graph to support must be provided.
Technical Specifications for one 5 kW Analog TV Transmitter System
S.No. Parameter
Value
A.C. input Power Supply
8.1.
415 V ±10%, 50Hz ± 2%
three phase 4-wire / 230V single phase
& power factor >0.9.
8.2.
(a)Ac power consumption of To be specified by the OEM.
TV transmitter system at black
level
(b) Ac power consumption of
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 11 of 118 cooling system
8.3.
8.4.
8.5.
8.6.
(c) Total power consumption of
Complete TV transmitter
system
Ambient Temperature(For
0o C to 45o C / -10o C to 50o C
operation/storage)
Relative Humidity
90% (max) at 40oC (non condensing)
Max Altitude
3500 m above sea level
Frequency
Transmitter
Range
of Any assigned channel between
470MHz to 862 MHz (Band IV / V))
with facility of frequency offset by
±2/3 of line frequency
8.7.
TV Standard
8.8.
Carrier frequency stability
8.9.
8.10.
Output
power
of
each 5kW
Transmitter
Aural Power: FA1= -13dB,
(Visual sync peak)
At the output of band pass filter FA2= -20dB, w.r.t. Visual Carrier
Power
RF output impedance
50 ohms unbalanced with VSWR <1.3
8.11.
Harmonic level
-60 dB below carrier level
8.12.
Spurious emission
-60 dB below carrier level
8.13.
Video input Level
Sync 0.3V ±6dB, video 0.7V
8.14.
8.15.
8.16.
8.17.
Video input impedance
Video input return loss
Video Frequency response
Random AM Noise (100kHz to
5MHz) RMS Value:
a) Unweighted continuous
b) Weighted continuous
c) Periodic Noise/Hum
75 ohms unbalance (BNC)
> 34 dB (Upto 5 MHz)
As per Table 1
PAL : 625 lines, CCIR - G
±150Hz over a period of three months
-52dB (RMS) or better
-60dB (RMS) or better
-46dB (p-p) or better
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 12 of 118 8.18.
8.19.
8.20.
8.21.
8.22.
8.23.
Waveform response:
a) 2T pulse
b) Line Tilt
c) Field tilt Filed T
Non Linear Distortion at
4.43 MHz:
A. Differential gain
B. Differential phase
within 2.0% K-rating
within 2.0% (1% K rating)
within 2 % (1% K-rating)
Within 5% (at APL 50%)
Within 5deg. (for modulation 10% to
87.5%)
Base –line distortion of 20T Less than 3%
pulse
Peak sync output stability
Better than ± 2% for any picture level
Group delay V/s
better than ± 50 nS
frequency response
without receiver precorrection
and sound trap off
(0 to 4.8 MHz)
Output power variation (Black Within ± 2%.
to white transition)
phase Within ± 4 deg
8.24.
Incidental
modulation
8.25.
(IMD)
Inter
distortion
for
amplification
8.26.
8.27.
Type of Amplification
Modulation
8.28.
Audio Input Level
8.29.
8.30.
8.31.
Audio Input Impedance
Audio Input Return Loss
Audio Frequency Deviation
(For 100% Mod.)
Modulation Capability
Upto ±75kHz deviation
Audio Carrier displacement at ± 50Hz (Max)
50 kHz deviation
8.32.
8.33.
carrier
modulation -58 dB or better
common
Common Amplification
Video: Negative AM (C3F) with
Colour PAL-B, Audio: FM (F3E)
-4dBm to +10dBm for ±50kHz
deviation
600 Ohms balanced
30dB (between 30Hz to 15 kHz)
±50KHz nominal
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 13 of 118 8.34.
AF Bandwidth
1. With pre-emphasis
2. Without pre-emphasis
30Hz to 15KHz
8.35.
Audio Pre-emphasis
50 microsecond
8.36.
Amplitude Vs Freq. Response
for audio (with 50%
modulation)
± 0.5 dB between 30Hz to 15KHz
8.37.
Harmonic distortion (audio)
Less than 0.5% within 30 Hz to
15KHz for 100% modulation i.e.
50KHz deviation.
8.38.
FM Noise (Unweighetd)
Better than –60dB
to100% modulation
(Weighted)
8.39.
(a)Dimension of transmitter
(L x B x H)
30Hz to 20KHz
with
respect
-66dB or less
To be specified by the suppliers in
meters.
(b) Dimension of Pump rack
(L x B x H)
(c) Dimension of Heat
exchanger (L x B x H)
8.40.
(a)Weight of transmitter
(b) Weight of Pump rack
The be specified by the suppliers in
Kgs.
(c)Weight of Heat exchanger
Table 1
Amplitude V/s frequency Response of the vision transmitter:
Freq. relative to carrier in
Limits (dB)
Limits (dB)
MHz
maximum
Minimum
-4.43
-30
-4.43 to -1.25
-20
-1.25 to -0.75
+0.5
-0.75
+0.5
-4.0
-0.5
+0.5
-1.5
0 to 1.5
+0.5
-0.5
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 14 of 118 +1.5
+3.0
+4.43
+5.0
+5.5
9
Reference
+0.5
+0.5
+0.5
-26
-0.5
-0.5
-2.5
-
A pre bid conference on technical specifications and other issues shall be held on
…………….. at …… Hrs in Conference Hall, Room No. 346, Directorate General, All
India Radio, New Delhi-110001, India. All prospective bidders may attend the pre bid
conference to discuss their queries/suggestions. All queries/suggestions should be sent at
least 2 days before pre-bid conference. No queries/suggestions shall be entertained after
pre-bid conference. Amendments subsequent to the pre bid conference shall be sent to
prospective tenderers, who have purchased tender document by e-mail/fax/post.
Amendment shall also be posted on All India Radio website www.allindiaradio.org. It
shall be tenderer’s responsibility to check for any amendments on AIR’s website before
submitting their duly completed bids.
10 General Requirements for completing the offer:
10.1 Technical Literature and Manuals: All the related technical literature,
pamphlets, manuals “in English” must be submitted with the offer without
which tender will be
considered incomplete & is liable to be
rejected. The detailed description regarding the installation manual and
operation & maintenance manual is given below:
10.1.1 Installation Manual: All the views, i.e. Front, rear, top and side, of
the TV Transmitter System with dimensions are to be provided. A
detailed diagram showing the cooling liquid Inlet to the transmitter
and the outlet to heat exchanger system should be provided. Typical
installation drawings with dimensions of Transmitter Rack(s), Pump
Rack and heat exchanger are to be provided. A detailed write up in
English regarding installing the TV Transmitter along with its
associated equipment items should be provided. The procedure of
alignment, and adjustment of various assemblies, sub- assemblies of
TV Transmitter System to be described in details in the installation
manual. A detailed description with all relevant circuit diagrams for
the control circuit of the transmitter should be provided. Procedure
for operating the transmitter on low power may be provided.
10.1.2 Operation and Maintenance Manual: All details regarding putting
“ON” with the sequence of operation of the Transmitter is to be
provided in the manual. The details of all electrical circuits in various
stages of the Transmitter used along with their write-ups are to be
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 15 of 118 provided in this manual. The various tests and measuring equipment
required and essential for the routine maintenance and calibration
along with the procedure for taking such measurement calibration
should be provided in the manual. Technical manuals of all the items
to be attached with the offer. The detailed procedure for trouble
shooting of the TV Transmitter System preferably up to component
level should be available in the manual. Various test fixtures and
accessories required for the maintenance/ repair of the TV
Transmitter System should be clearly described and detailed out in
this manual. The systematic trouble shooting/ fault tree and flow
diagram should be provided for diagnosis of the fault with its
remedial measures in this manual. The operating manual should have
description regarding various interfaces, connectors, connecting
cables and accessories required for the satisfactory function of the TV
Transmitter System. All such items required should be provided by
the manufacturer along with the transmitter system.
10.2 ATP:
10.2.1 A copy of ATP (Acceptance Test Procedure) must be submitted by
the bidder within one month of issue of Purchase order for
acceptance by Doordarshan.
10.2.2 ATP should describe the standard testing procedures and the details
of test benches for carrying out measurement etc. for the offered
transmitter and the antenna system. The test reports will not be
treated as ATP.
10.2.3 The respective OEMs only shall prepare the ATP for their product
being offered.
10.2.4 The accepted/approved ATP with or without changes shall be sent
back to the bidder to be used for inspection of transmitter/antenna
systems by DD Engineer(s) at respective OEM’s works before
dispatch of transmitter/antenna systems.
10.2.5 The bidder has to intimate DD for inspection and testing of the
offered TV Transmitter System/antenna system, at least six weeks in
advance when the transmitter/antenna systems are likely to be ready
for inspection. Inspection period for Transmitters/antenna will be
three days each, at respective OEMs’ location.
10.3 Software:
10.3.1 One set of Copies of all softwares used in the transmitter and allied
equipment should be provided in the form of CD besides being
loaded in to the system.
10.3.2 Any Future upgrade of software within five years of supply of
equipment shall be made available free of cost to Doordarshan.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 16 of 118 10.3.3 All software licenses are to be provided to Doordarshan on perpetual
license basis without specifying any time limit or without specifying
any ‘end of life’ of any of the softwares supplied.
10.4 Training:
10.4.1 A proposal for training for four Doordarshan engineers at
Transmitter site for five days to enable them to
become
acquainted with all particulars as well as installation, operation,
trouble shooting and maintenance of the Transmitter, Auxiliary
Equipment & accessories should also be attached with the offer.
10.4.2 The training programme will be structured so as to cover
theory of operation Maintenance, Practical demonstrations of
circuits, Maintenance demonstrations, Fault finding, Circuit
Tracing exercises and Part Replacements.
10.4.3 For Training of Engineers expenses toward to and fro air journey,
boarding, lodging etc. will be borne by Doordarshan. The offer
shall cover training fee only.
10.4.4 Two sets of training lecturers notes, schematic drawing, hand
book etc. shall be supplied to DE(Transmitter Design), DG: DD.
10.5 Guarantee:
10.5.1 The bidder/OEM shall guarantee the satisfactory working of all the
equipment including Transmitter system, input, monitoring and all
the allied equipment offered with the transmitter System without any
fault & defect for two years from the date of completion of
acceptance test at site of the Transmitter System. Any defect/ failure
of component, module, assembly of any equipment and it’s nonperformance during this period is to be set right by the bidder/
manufacturer(s) free of cost and deliver the repaired/replaced item(s)
at the premises of the consignee.
10.5.2 Any module/Assembly/ Sub Assembly of the transmitter system
failing during the guarantee period shall be repaired/replaced free of
charge by the supplier at site. The transportation charges if any shall
be borne by the supplier. Guarantee period would be extended
corresponding to the outage period, of that module/Assembly/ Sub
Assembly, if the repair/replacement of the failed item takes more
than 20 days.
10.6 Past Supply record:
10.6.1 Documentary evidence of past supply record of similar type of TV
Transmitter System must be provided with the offer. Performance
certificates issued by users for similar type transmitter system may
also be enclosed.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 17 of 118 10.6.2 The detail of Past Supply Record must be submitted in the
following format, Doordarshan reserves the right to get
performance feedback of the transmitter system from any of the
user(s) as mentioned in past supply record:
Order
No. with
date,
reference
(1)
Transmitter Quantity Name of the
Type, Model
broadcaster with
and Power
full postal
of
address to whom
transmitter
transmitter was
supplied.
(2)
(3)
(4)
Name, Telephone, Fax,
Email ID of concerned
personnel, purchaser, for
getting feedback on
transmitter performance
(5)
10.7 Experience:
10.7.1 The OEM of the transmitter system must have an experience of
manufacturing and supplying TV transmitters at least for last 10
years.
10.7.2 The OEM of the antenna system must have an experience of
manufacturing and supplying broadcast antennae at least for last 10
years.
10.7.3 In case the bidder is the authorized representative, the bidder must
be in the business of sales, supply and integration or turnkey
execution of broadcast transmitters for last two years.
10.7.4 Documentary evidence in support of the experience as mentioned in
above three paras must be attached with the offer failing which the
tender will be considered incomplete and is liable to be rejected.
10.7.5 The Antenna Manufacturer must have his own test bench including
test field, rotating tower, suitable receiving equipment for measuring
various parameters and their analysis. Necessary supporting
documents along with the details, drawings, photographs etc. of the
above test bench facility must be provided with the offer.
10.8 Maintenance support/spares:
10.8.1 The minimum recommended essential spares (like modules of PA,
Power Supply Modules or any other critical spares suggested by the
OEM), required to maintain the continued service of transmitter in a
reliable manner, shall be quoted separately by the supplier
positively.
10.8.2 The spares shall be treated as optional items and the cost of spares
shall not be taken into account while deciding the lowest bidder.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 18 of 118 10.8.3 The minimum, recommended essential spares may be based on
predicted rate of failure and requirement for three years.
10.8.4 The manufacturer shall also give a certificate attached with the offer
to supply maintenance support and all spares during the lifetime of
the TV Transmitter System. The life of the TV transmitter system
should be certified by the manufacturer. This is an essential
requirement. The life of transmitter should be more than Ten years.
10.8.5 The bidder must also attach with the offer the certificates to supply
all spares, installed softwares and software updates for providing
maintenance support during the lifetime of all the input, monitoring
and all other auxiliary items/equipment offered with the transmitter
system.
10.8.6 The life time of each equipment/items/allied equipment supplied is
to be specified by the respective OEMs. These certificates duly
signed are to be provided by the respective OEMs only on their letter
heads.
10.8.7 In addition, the bidder shall provide, in the following format, the
address and contact information for after-sales-support of all the
equipment including all the third party bought out equipment
that are to be supplied with the transmitter system as part of input,
monitoring, measuring or allied equipment.
Name of
OEM
Equipment
with
model No.
(1)
(2)
After sales &
support office
address
(3)
Name,
Authorization by
Telephone/ Fax/ the OEM for
Email of
supply and after
concerned
sales support of the
personnel
equipment
(4)
(5)
10.9 Local Representative/Dealer:
10.9.1 The transmitter manufacturer shall give the address of the local office
/Representative/Dealer in India to facilitate interaction.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 19 of 118 10.9.2 In case any item of transmitter system requires repairs at
works/factory, the same would be handed over to local office
/Representative/Dealer in India, who would arrange export of the item
to works/factory and re-import in India after repairs. After sales service
and maintenance support of the transmitter system should be available
in India through the local office /Representative/Dealer.
10.9.3 Copy of Agreement/ MoU signed in this regard between OEMs and
their local representative/dealer must be submitted with the offer.
11 Information to be furnished by successful bidder:
11.1 On acceptance of the tender, the name of the accredited representative(s)
of the Bidder who would be responsible for taking instructions from DG:
DD, New Delhi-110001 or his authorized representative should be
communicated in writing to Indenter within 15 days.
11.2 Copies of packing slips and other details should be sent separately to the
consignee and also to The Director Engg. (Transmitter Design),
Doordarshan Directorate New Delhi.
12 Inspection:
12.1 The inspection of the TV Transmitter System and the antenna system at
the OEM’s premises before the dispatch of the transmitter system and
antenna system shall be performed by DD Inspectors at respective OEMs’
works.
12.2 The bidder has to intimate DD at least six weeks in advance when the
transmitter/antenna is ready for inspection.
12.3 The approved ATPs shall be used for testing the transmitter/antenna.
12.4 In case pre dispatch inspection at the Manufacturers’ facility is not carried
out by DD engineer(s) due to any reasons, Copies of factory test reports &
test data along with guarantee certificates shall be furnished by the OEM.
12.5 The expenditure for DD inspectors on To & fro airfare, per Diem
allowances, lodging, boarding charges etc. shall be borne by Doordarshan.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 20 of 118 The bidder in his offer shall cover inspection fees only. The inspection fee
if any shall be included in the main BOM for deciding the lowest offer.
12.6 . All other associated equipment, items and accessories will be accepted
on the basis of Original Equipment Manufacture’s (OEM) Test
Certificates (as per DD Specification) duly signed and stamped on the
letter head of the OEM, failing which Original Equipment Manufacturer’s
(OEM’s) Test Certificates will be considered incomplete and equipment
offered by the firm is liable to be rejected.
13 Installation, testing and commissioning at site:
13.1 The transmitter and antenna system shall be supplied, installed and tested
by the supplier/OEMs as per the specifications of Doordarshan.
Thereafter, commissioning of the complete system will be carried out, in
the presence of DD representative, by the supplier/OEMs’ representative
engineer(s). The supplier/OEMs will intimate Doordarshan at least 20 days
in advance, when the system has been installed, tested and is ready for
acceptance measurements, testing and commissioning.
13.2 For this purpose complete Test Procedure will be prepared by the
supplier/OEM(s). The test procedures will indicate full details of test set
up for measuring / testing required during the Performance Measurement/
Acceptance Testing at the site. All equipment required for measurements
and testing of Transmitter System, other auxiliary equipment and antenna
system has to be arranged by the bidder at the site.
13.3 Installation, testing and commissioning of the transmitter and antenna
system as per specification shall be done under the supervision of
Qualified Engineers of OEMs duly trained and certified by OEMs of main
equipment i.e. transmitter and antenna at site.
14 BOM:
14.1 A detailed, complete Bill of material (deliverables) shall be attached with
the technical bid leaving price column blank. This Bill of material (BOM)
shall be exactly in the same format as in the price bid minus the price.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 21 of 118 14.2 Make, model and quantity of each item must be mentioned clearly in the
B.O.M. In case of ‘kits’ complete details of all components that form
part of kit should be spelt out/clearly given i.e. the details of the
component/item offered in the kit including their part no. and quantities.
14.3 The bidder must quote the complete transmitter system, antenna system,
power supply equipment etc. as per the suggestive list of items provided in
Annexure IA & IB. Annexure IA is the suggestive BOM for DD National
and DD News TV Transmitter system while Annexure IB is the suggestive
BOM for common items for both TV Transmitter systems.
14.4 The complete system integration for all items must be guaranteed by the
bidder for its working as per the requirements & Specifications of
Doordarshan. The partly quoted system shall not be accepted.
14.5 Any other items that are not listed in the suggestive BOM by Doordarshan
but are essential for completeness of the system must be quoted by the
bidder.
15 Following Points are to be noted by the bidder and complied for the TV
Transmitter set up at AIR FM site in Rajouri:
15.1 As a part of SITC, 6.2 M C band, 2.4 M Ku band PDAs are to be installed
including foundation of PDAs. The suitable structural drawing for the
foundations of PDAs shall be attached with the offer.
15.2 After the strengthening of tower, the required length of horizontal RF
Feeder cable rack & required length of Vertical Feeder cable rack on 50M
AIR FM tower for RF Feeder cable to feed the antenna system installed on
50M AIR FM tower top must be provided by the bidder. The location and
routing of the vertical and horizontal cable racks/trays shall be decided in
consultation with DD/AIR representatives at site.
15.3 Full Electrical wiring diagrams and interconnection diagrams for whole
set up being supplied and installed is also to be provided with the offer
alongwith the block schematic of the system.
15.4 Bidder must ensure the General Safety conditions for SITC of project.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 22 of 118 15.5 Bidder shall make good all damages to the purchaser’s building, property,
equipment etc. how-so-ever arising while doing strengthening of the AIR
FM tower, construction PDA foundations and carrying out the entire SITC
work throughout the period of execution of the SITC Project at AIR FM
Rajouri site.
15.6 The Bidder shall indemnify and hold harmless the purchaser against any
claims in respect of damages to building, property situated nearby, not
belonging to the purchaser, how-so-ever arising while doing strengtheing
of the AIR FM tower, construction PDA foundations and carrying out the
entire SITC work throughout the period of execution of the SITC Project
at site.
15.7 The Bidder shall indemnify and hold harmless the purchaser against
claims in respect to injury any mishap to any person how-so-ever arising
while doing strengthening of the AIR FM tower, construction PDA
foundations and carrying out the entire SITC work throughout the period
of execution of the SITC Project.
15.8 The Bidder shall discharge all obligations under the Indian workmen’s
compensation act, any local/state laws and regulations in so far as it affects
the workmen in his employment during the full period of the execution of
the entire SITC Project.
15.9 The Tenderer should conform to all local State laws/Central laws and
regulations amended up to date concerning labour and their employment
as applicable. The insurance etc of the labourers shall be the responsibility
of the Tenderer including any kind of pre /post action and consequences
relating to above insurance etc.
15.10
Prior approval of the purchaser, in writing, shall be obtained, if the
bidder desires to sublet or assign any section of the work associated with
the fabrication, work related with strengthening of tower etc to any other
agency. Such permission or consent shall not, however discharge the
bidder from his liabilities in this contract or any part thereof.
15.11
The bidder shall make his own arrangements for power supply,
water and the safe custody of materials at site for the entire SITC project.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 23 of 118 15.12
The bidder shall make his own arrangement for employing labour,
skilled & unskilled, and shall make his own arrangement for providing
accommodation for his workmen at site or elsewhere during the entire
SITC Project.
15.13
After completion of SETC work the Tenderer shall remove dust,
dirt, debris and leave the building/ premises in a clean condition.
16 Compliance Statement: A para by para compliance statements in the format given
below, with page numbers of the tender document describing DD specifications, of
the manufacturers quoted items and remarks, should be attached with the offer by the
manufacturers only on their letter head duly signed but not by the local agent or local
representative of the manufacturer with the relevant supporting literature, manuals
etc. The bidder shall countersign all the compliance statements. The compliance
statements should be provided for all the technical as well as general specifications
for all the paras listed above and all the annexures in these specifications. This is a
mandatory and essential requirement. Mere signing of DD Specs sheets shall not be
treated as compliance statement. Any offer without the compliance statements for all
paras as detailed above as well as compliance statement in respect of the
items/equipment, specifications, Annexures shall be rejected in the first instance
without making any reference to the bidder. The entire technical bid shall be page
numbered and each page shall be signed by the bidder.
Para No. Of
DD Spec.
(1)
DD spec
value &
Details
(2)
Quoted items
value and details,
as per the data
sheet of offered
system.
(3)
The page no. of the
Compliance Remarks
offer/Technical bid,
OR
where the
Deviation
information/supporting
document is available.
(4)
(5)
(6)
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 24 of 118 ANNEXURE-I-A
(SUGGESTIVE BILL OF MATERIAL)
SUGGESTIVE LIST OF MATERIAL FOR 5KW, UHF, DDNATIONAL AND DD- NEWS, Band IV/V Analog TV
TRANSMITTER SYSTEMS & THEIR STATION ITEMS
S. NO. DESCRIPTION
MAKE/MODEL QTY.
1
5 KW, UHF, BAND IV/V, Analog (common amplification
2SETS
type), upgradable to DVB-T2, Transmitter System as per DD
specifications with all items required to complete the entire
complete
system, including:
in all
(a) TRPA extender module.
respect
(b) Dual Exciter system with DSP.
(c) Liquid pump assembly including all pipes and
accessories, alongwith spare coolant and coolant filling
arrangement.
(d) Heat exchanger unit to work for temperature range
-10ºC to 50 ºC.
(e) Transmitter control unit with necessary software.
(f) Power amplifiers with inbuilt power supply
(g) All items of transmitter to complete it as a full system.
(h) Installation, Maintenance & Operational Manuals & test
data
(i) Transmitter output 3⅛”EIA unflange.
(k) Any other item(s) to complete the transmitter system
2
3 Phase unbalanced AVR and Power Distribution Panel (with
2 Nos.
phase sequence reversal sensing and protection circuit) and
Surge suppressor in Air cooled construction as per DD
Specifications given in Annexure I-1
(One AVR each with one Transmitter)
3
OUTPUT COAXIAL EQUIPMENT
3.1
Broadcast Power Monitor, UHF Band IV/V, with 3 ⅛” EIA
2No
unflanged line section and suitable elements for measurement
as per DD Specifications given in Annexure I-2
4
INDOOR COAXIAL FEEDER COPPER COMPONENTS
ONLY (AS PER THE ACTUAL INSTALLATION
REQUIREMENT IN THE EQUIPMENT CONTAINER)
as per DD Specifications given in Annexure I-3
3 ⅛” EIA Straight Transmission Line Copper Sections
(VSWR<1.05) Sections of length 5 to 6 Meters may be used to
4.1
DGDD/TxD/5kWHPT Specs/J&K/2010 2 Lots (one for
each transmitter)
As per the actual
installation
Page 25 of 118 minimize coupling joints.
3 ⅛” EIA 90 DEG. ELBOW (VSWR<1.05)
4.2
4.3
4.4
Straight Coupling 3 ⅛” EIA (with inner and outer conductor
and two nos of hose clamps for each Straight coupling)
(VSWR<1.05)
Fixed Hanger Assy 3 ⅛” EIA (VSWR<1.05)
4.5
3 ⅛” EIA Flange to Non flange adopter (VSWR<1.05)
5
INPUT & MONITORING EQUIPMENT TO BE
PROVIDED WITH EACH 5 kW TRANSMITTER:
VIDEO EQUALISING DA as per DD Specifications given in
Annexure I-4-II, comprising of:
Video equalizing amplifier with clamp
5.1
5.1.1
5.1.2
Audio Video mounting frame, 2RU, looping inputs with power
supply and card.
Redundant power supply
5.1.3
5.2
requirement
As per the actual
installation
requirement
As per the actual
installation
requirement
As per the actual
installation
requirement
As per the actual
installation
requirement
2 sets (one for
each transmitter)
2 Nos. (one for
each transmitter)
2 Nos(one for
each transmitter)
2 Nos (one for
each transmitter)
2Sets. (one for
each transmitter)
Audio stereo Monitoring Amplifier 8 W with compatible loud
speaker as per DD Specifications given in Annexure I-4-VI
Audio Distribution Amplifier housed in a suitable frame with
redundant power supply & extender card, as per DD
2 sets (one for
Specifications given in Annexure I-4-VII:
each transmitter)
Stereo analog audio distribution amplifier (4 stereo balanced
2 Nos. (one for
outputs)
each transmitter)
Audio DA mounting frame, including plug in audio
2Nos. (one for
connectors, one power supply and power cord.
each transmitter)
Audio Processor as per DD Specifications given in Annexure
2 Nos. (one for
I-4-VIII
each transmitter)
Amplispeaker as per DD Specifications given in Annexure I2 Nos. (one for
19
each transmitter)
AUDIO VIDEO SWITCHER as per DD Specifications given in Annexure I-4-III
5.3
5.3.1
5.3.2
5.4
5.5
5.6
5.6.1
10X2 Audio, Video married switcher with redundant power
supply and extender card consisting of:
DGDD/TxD/5kWHPT Specs/J&K/2010 2 Sets
Page 26 of 118 5.6.2
5.6.3
Audio video + Stereo Audio, Router switcher with internal
power supply and extender logic card.
Redundant External AC power supply for 2RU frame
5.6.4
local programmable push button
5.6.5
Mounting tray for external power supply
6
VIDEO MONITORING SYSTEM
6.1
WAVEFORM MONITOR as per DD Specifications given in
Annexure I- 5-I (PAL 625/50 waveform monitor)
26” LCD TV Receiver with VHF/UHF PAL-G Tuner, AV
input facility (Only Reputed Brand like
Sony/Panasonic/Hitachi/Samsung/LG/JVC is to be quoted)
29” LCD TV Receiver with VHF/UHF PAL-G Tuner, AV
input facility, Yagi antenna and twin RF cable for off Air RF
Monitoring (Only Reputed Brand like
Sony/Panasonic/Hitachi/Samsung/LG/JVC is to be quoted)
VU Meter Assy, with Power Supply Unit etc complete as per
DD Specifications given in Annexure I-5-II
INSTALLATION MATERIAL: Miscellaneous installation
material like coaxial cables, connectors, PTFE cables, RF
Cables, 75 ohm connectors, 50 ohm connectors, power cables,
flexible cables, etc. as per DD Specifications given in
Annexure I-6
ANY OTHER ITEMS FOR COMPLETING THE SYSTEM
(If any, Breakup Detail must be given)
Computer with 1KVA UPS and Printer-Laserjet as per DD
Specifications given in Annexure I-7
6.2
6.3
6.4
7
8
9
DGDD/TxD/5kWHPT Specs/J&K/2010 4Nos. (two for
each transmitter)
4Nos. (two for
each transmitter)
2 sets. (one for
each transmitter)
2 Nos. (one for
each transmitter)
2 Lots as per
requirement at
site for two
transmitters.
1Set
4 sets (Two with
each transmitter)
Page 27 of 118 ANNEXURE-I-B
SUGGESTIVE LIST OF MATERIAL OF COMMON ITEMS FOR 5KW, UHF, Band IV/V DD
NATIONAL & FOR 5KW, UHF, Band IV/V DD NEWS, ANALOG TV TRANSMITTER
SYSTEM & STATION ITEMS
MAKE/MOD
SL. NO. DESCRIPTION
EL
QTY.
1
DUMMY LOAD - Forced air cooled, 10 KW RMS power,
1No
UHF Band IV/V, 50 OHMS, 3 ⅛” EIA UNFLANGED
CONNECTOR, Input 230VAC as per DD Specifications
given in Annexure I-8
2
MEASURING EQUIPMENT
2.1
Colour Test Pattern and Tone Generator as per DD
1Set
Specifications given in Annexure I-9-I
2.2
T.V. Analyzer/Demodulator as per DD Specifications given in
1No
Annexure I-9-II
2.3
Digital Storage Oscilloscope,100MHz, 2channel (with user &
1No
service manuals and standard accessories like one power cord,
two nos. of passive probes, certificate of calibration etc.) as per
DD Specifications given in Annexure I-9-III
3
MISC ITEMS FOR MON. & MAINTENANCE
3.1
RF Power Meter With Power Sensors as per DD specifications
1No
given in Annexure I-20
3.2
STEP ATTENUATOR (0-110dB) as per DD Specifications
1No
given in Annexure I-10-I
3.3
ATTENUATOR 3dB (N type) as per DD Specifications given
1No
in Annexure I-10-II
3.4
ATTENUATOR 6dB (N type) as per DD Specifications given
1No
in Annexure I-10-II
3.5
ATTENUATOR 12dB (N type) as per DD Specifications
1No
given in Annexure I-10-II
3.6
REDUCER 3 ⅛" unflanged to N Female(VSWR<1.05) as per
DD Specifications given in Annexure I-3
3.7
REDUCER 3 ⅛" unflanged to 1 5/8” unflanged (VSWR<1.05)
as per DD Specifications given in Annexure I-3
3.8
REDUCER 1 ⅝" unflanged to N Female(VSWR<1.05) as per
DD Specifications given in Annexure I-3
Total
4
TECHNICAL MANNUALS of all equipments provided as
5 Sets
per BOM.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 28 of 118 One sets of all manuals per order for DGDD.
Two sets of all manuals for zonal office per order.
Two sets of all manuals for the station.
ANTENNA SYSTEM as per DD Specifications given in
Annexure I-11-I
10 KW, Band IV/V UHF Super turnstile, Omni directional,
Broadband antenna system.
5
5.1
5.2.1
1Set
Complete
Antenna interface for mounting the antenna on top of existing
AIR FM tower.
Horizontal cable rack and a vertical cable rack as per the actual
requirement a site.
Lightening Protection & Aviation Light
1Set
Complete
1 Set
Automatic dehydrator system with tubing and sealing
compound for joints etc. as per DD Specifications given in
Annexure I-11-III
2X5 KW, 2 Channel Constant Impedance UHF Combiner as
per DD Specifications given in Annexure I-11-IV
3⅛” EIA Flange to Non Flange Adapter (VSWR<1.05dB)
1Set
Complete
All hardware items including sealing compound with breakup
of item wise details.
Any other item for completeness of antenna system.
7.1
Seven Port Patch Panel as per DD Specifications given in
Annexure I-12
RF FEEDER CABLE - (single length) as per DD
Specifications given in Annexure I-13
Cable 3⅛”/4” including drum charges
1Set
Complete
1Set
Complete
1Set
Complete
85 meter
length
1No
7.2
Connector 3⅛”/4” EIA Flange Gas barrier flange
1No
7.3
Connector 3⅛”/4” EIA Flange Gas Pass Flange
1No
7.4
Coupling element for 3⅛”/4”
2Nos
7.5
Grounding kit pre-formed copper strap
2Nos
7.6
Wall gland, Single entry
1No
7.7
Hoisting stocking as per the OEMs Single specified value
Depending
5.2.2
5.2.3
5.3
5.4
5.5
5.6
5.7
6
7
DGDD/TxD/5kWHPT Specs/J&K/2010 1 Set
1No
1No
Page 29 of 118 7.8
Cable Clamps (To be fixed 1 M apart) (see notes below BOM)
7.9
Cable Trays/Racks (a) Horizontal (b) Vertical.
(see notes below BOM)
Any other item required to complete the system
7.10
8
C BAND/KU BAND SATELLITE RECEIVE
EQUIPMENT
6.2 Mtr C-Band solid type PDA system with de-icing kit 100%
full surface including dual port motorized feed and necessary
mounting accessories. as per DD Specifications given in
Annexure I-14-II and IV
C-Band LNBC units with de-icing kit . as per DD
Specifications given in Annexure I-14-VI
8.1
8.2
8.3
Low loss Rf Cable in the denomination of 50m & 25m and
necessary connectors as per DD Specifications given in
Annexure I-14-III
Professional IRD unit for C band & Ku band feed operating
with stand by facility as per DD Specifications given in
Annexure I-14-I
2.4 Mtr Ku-Band dish antenna with Feed and necessary
mounting accessories (with slanting shed for snow/rain
protection) as per DD Specifications given in Annexure I-14IV
Ku-Band LNBC units as per DD Specifications given in
Annexure I-14-VII
Low loss RF Cable for Ku band as per DD Specifications
given in Annexure I-14-III
DG SYSTEM OPERATING IN (1+1) STANDBY MODE
as per DD Specifications given in Annexure I-15
8.4
8.5
8.6
8.7
9
on the
length of
cable
1 lot
1 set
1Set
2Sets
4Nos (2
Nos. with
each 6.2m
PDA)
2 x 75 m
4Nos
1 Set
1 No.
25Mtr
9.1
DG Engine + Alternator 80KVA
2Nos
9.2
AMF Panel
1No
9.3
Power cable.
2X25Mtrs
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 30 of 118 9.4
1 lot
9.5
Other installation material as per the site requirement to route
the DG in the container.
Voltage and Current display panel
9.6
Output terminal blocks
8Nos
9.7
Flame retardant canopy with ISO corners
2Nos
10
1Set
10.1
UPS SYSTEM Consisting of as per DD Specifications given
in Annexure I-16
UPS: 60 KVA, 3Ph, 415 V AC as per DD specifications
10.2
100% rated In-built Static Bypass
1 No.
10.3
100% rated In-built Maintenance Bypass
1 No.
10.4
Battery Path Isolation Device of appropriate rating
1 No.
10.5
1 set
10.6
Battery Bank: Set of 2 Volts MF VRLA Cells (20 year Float
Life) 15 Minute Back-up (Make Amara Raja/GNB/HBL)
Interconnecting cables between UPS to Battery
1 set
10.7
Battery Racks, Interconnections and Accessories
1 set
10.8
Operation & Maintenance Manual
1 set
10.9
Input Isolation Transformer 90 KVA
1 No.
11
1Set
11.1
Container with sloping roof for protection from snow/rain
with ISO corners 20’x8’x8’for equipment provided with
following items (as per DD Specifications given in Annexure
I-I7):
Smoke detector System
11.2
Power supply Interlock System
1Set
11.3
Fire extinguisher system
1Set
11.4
Storage racks
1Set
11.5
Shock absorbers for all equipments
1Set
11.6
Air Conditioning System (Reversible Type) with Air
Conditioners having the facility of cooling and heating to
maintain the ambient temperature 23oC in all weather
Complete
Set installed
in the
DGDD/TxD/5kWHPT Specs/J&K/2010 1No
1 No.
1Set
Page 31 of 118 12
12.1
12.7
12.8
12.9
13
14
conditions inside the above container of size 20’x8’X8’ with
all equipment installed and both the transmitters running on
full power.
19” WIRED INPUT & MONITORING RACKS
container
Standard 19” wired Racks for Input & Monitoring Equipment
as per DD Specifications given in Annexure I-4-I
AUDIO JACK PANEL-(N/C) 2x24
2 Nos.
AUDIO PATCH CORD (2ft length) as per DD Specifications
given in Annexure I-4-IX
VIDEO PATCH PANEL WITH 5 NOS PATCH CORD (2ft
length) (N/C) as per DD Specifications given in Annexure I-4X
System Integration of the Racks
10Nos
INSTALLATION, TESTING AND COMMISSIONING
INCLUDING MEASUREMENTS AT SITE FOR THE
FOLLOWING ITEMS:
Strengthening/Modification of existing 50Mtr. steel tower (as
per the latest BIS codes for wind and seismic zone) to take the
load of Antenna system, RF Feeder cable etc.
Required Horizontal and Vertical Cable Racks/Trays
14.1
14.2
14.3
1No
1No
1Job
1 Job
1 Job
Complete Antenna System with tower top interface, mounting
arrangement, aviation light, lightening protection, radome,
ladder etc., RF Feeder Cable, Combiner, Dehydrator with
tubing
Two Nos. of 5 kW Transmitters including Power Supply
System, Cooling System, Input-monitoring-measuring
equipment, Coaxial RF components etc.
Satellite receive equipment for C Band (PDAs, feeds, LNBCs,
IRDs, Cables) including foundation of 6.2 M PDAs.
1 Job
14.6
Satellite receive equipment for Ku Band (PDAs, feeds,
LNBCs, IRDs, Cables) including foundation of 2.4 M PDAs.
1 Job
14.7
Any Other items to complete the turnkey job as per
specifications
Inspection Fee for inspection at
1 Job
14.4
14.5
15
DGDD/TxD/5kWHPT Specs/J&K/2010 1 Job
1 Job
Page 32 of 118 1) Transmitter OEM’s works
1 Job
2) Antenna OEM’s works
1 Job
16
Miscellaneous items
16.1
Audio Analyzer as per DD Specifications given in Annexure
I-18
Optional Items:
1) Minimum recommended essential spares as per DD
specs Para 10.8. The detail Breakup is to be provided in
BOM by the bidder
2) Items required for upgradability to DVB-T2 (break up
detail to be given)
17
Training (Fee Only) for training at Transmitter site
18
1No
1Lot
1 Lot
1 Lot
Notes:
1. For ascertaining the lowest bidder the cost of 50M for Vertical Cable Racks, 20M
horizontal Cable Trays and corresponding No. of cable clamps will be considered.
However, the payment will be made on the basis of actual measurement of
Vertical Cable Racks, Horizontal Cable trays and clamps erected actually at
Rajouri site.
2. Items in the BOM are on SITC basis.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 33 of 118 Annexure I-1
Specifications of 50 KVA AVR and Power Distribution Panel:
INTRODUCTION:
a. Servo Controlled Automatic Voltage Regulator (AVR) is to be used in TV
Transmitters and with other transmission equipment so that these sensitive
equipment are protected from low voltage / high voltage and power supply
fluctuations and surges.
b. The AVR should be rugged, reliable and stable for continuous operation.
c. It should be naturally air cool type housed in one steel cubicle and hook at
the top for lifting.
d. It should be from reputed manufacturer who are ISO 9001/ ISO 14001
certified.
TECHNICAL SPECIFICATIONS:
S. N. Parameter
Value
2
Inputs
2.1
Nominal voltage
400 V, 3 Phase
2.2
Range
340 V to 440 V
2.3
Frequency
48 to 52 Hz
2.4
Waveform
Sinusoidal
3
Outputs
3.1
Nominal voltagePhase
400 R.M.S. + 1.0%, 3 Phase
3.2
Settability
400 V to 410 V R.M.S.
3.3
Load regulation
+ 1.0%
3.4
Line regulation
+ 1.0%
3.5
Capacity
50 KVA
3.5
Waveform
Sinusoidal
4
> 95% at full load, unity power
Efficiency
factor and at
minimum input voltage
5
Correction speed
> 30 V/Second. Phase to phase.
5.1
Switch on delay with timer and 0 to 60 seconds.
contactor
6
Protections
6.1
Overload capacity
25% for half an hour.
6.2
Output under voltage
380V Disconnecting the load
through a
contactor with alarm bell.
6.3
Over voltage
430 V, Disconnecting the load
through a contactor with alarm bell.
6.4
Over load tripping
Disconnecting the load through a
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 34 of 118 6.5
6.6
6.7
7
8
9
11
12
contactor with alarm bell.
Power factor effect
Nil
Waveform distortion
Less than 1% at full load
Line noise suppression (for control Line noise to be suppressed by at
circuit only)
least 30dB for frequency range 10
MHz to 250 MHz
(a)Analog or digital voltmeter to be
Metering
provided to read input & output
R.M.S. Voltages of each phase
selected by selector switch.
(b)Analog or Digital Ammeter to be
provided to read current of each
phase selected by selector switch.
Indications
(a) LEDs for indicating
(i) Input on (ii) Out put on.
(b) LED for indication of input
power
(i) LED for indicating low input.
(ii) LED for indicating of input OK.
(iii) LED for indication of high
input.
(a) Output On-Off through MCCB.
Controls
(b) Auto-Manual switch selection.
(c) Raise/lower the output voltage in
manual
mode.
(d) Manual By pass in case of
Malfunction.
(a)Suitable input & output
Input/ Output terminations
terminations should
be provided. These terminals along
with other
distribution board output terminals
shall be
provided with acrylic sheet, so that
these
terminals are not accessible
inadvertently.
(b)Earthing terminal is to be
provided.
To be specified by the vendor.
Weight & Dimensions (LxBxH)
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 35 of 118 13
13.1
13.2
13.3
13.4
14
14.1
14.2
14.3
14.4
14.5
14.6
15
15.1
Environmental specifications
Ambient temperature range
0o C to + 45o C (operative)
Storage temperature range
-10o C to + 50o C.
Relative Humidity
95% at +40o C.
Type of cooling
Natural air cooling
Notes:
Derating factor (adequate) should be applied to critical components while
designing to improve life expectancy.
All the transformers and chokes must be varnish impregnated.
All the components used should be of reputed make.
PCB should be of glass epoxy material and heavy components & high
power
dissipating components like transformers, chokes, high power
transformers should not
be mounted directly on the PCB.
AVR should be subjected to 100 hrs. Heat Run Test at max. load under
normal ambient
temperature condition.
AVR should be compatible & according to latest National and
International standards on
safety & EMC. Standards followed should be stated.
Guarantee: Two years from the date of receipt of equipment.
Past supply record of manufacturer in supplying similar capacity AVR to
other organization may be attached.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 36 of 118 Annexure I-2
SPECIFICATIONS OF 10KW BROADCAST POWER MONITOR (THROUGH
LINE POWER METER):
1. Introduction:
1.1 Broadcast Power Monitor, UHF Band IV/V, with 3 ⅛” EIA unflanged line section
and suitable elements for measurement of Max Forward power of 5 kW and reflected
power of 0.5 KW, VSWR, Return Loss etc.
1.2 Ethernet & RS 232 enabled- Remote monitoring, control & instant alarm alert with 50
feet of cable to connect RS 232 and serial port between monitoring unit and line section,
and serial interface cable.
1.3 Data logging capabilities – System trends and anomalies before failure.
1.4 Integral RF Test Port facility.
1.5 Frequency / Channel field configurable.
3. Technical specifications:
S.No. Description
Technical Specification
a)
b)
c)
d)
Accuracy
Connector
Frequency Range
VSWR
±5% of reading
3⅛” EIA UnFlange
470 to 862 MHz
< 1.10:1
e)
f)
Impedance(Nominal)
Alarms
g)
AC Power
h)
Temperature of Storage
50 Ohm Nominal
No/Low Forward power,
High forward power,
VSWR
Single Phase, 230
volts(rms) + 10%,
50 Hz + 4%
-30ºC to 50ºC
i)
Temperature of
Operation
Humidity
Max Altitude
Display
j)
k)
l)
0ºC to 45ºC
95% NC
3500 Meter.
Broadcast power
monitor
DGDD/TxD/5kWHPT Specs/J&K/2010 Remarks with
Technical
Data/Schematic
drawings Etc.
Page 37 of 118 m)
n)
o)
Coupler Directivity
Dimensions:
(Length x Width x
Depth)
Weight
28dB minimum
To be specified by the
bidder
To be specified by the
bidder
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 38 of 118 Annexure I-3
SPECIFICATIONS OF INDOOR COAXIAL FEEDER CU COMPONENTS:
1. Introduction:
1.1 All the indoor coaxial feeder components must be of high quality copper, used for
broadcasting system for a good transmission performance.
1.2 The VSWR of all coaxial feeder components must be less than 1.05.
1.3 There should be a firm grip between various coaxial feeder components.
1.4 All the components should be capable of handling the power supplied output of the
transmitter.
1.5 Spacers must be used at a suitable length between inner and outer conductor.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 39 of 118 Annexure I-4
Specifications of Input, Monitoring equipment and Racks:
I. Specifications of Standard 19” Rack:
i) The Stereo/mono audio and video programme input and monitoring rack should be
suitable for:
Feeding stereo/mono audio and video programmes to TV transmitters, &
ii) Metering/monitoring of different programme input sources as well as signal at
intermediate points in the audio/video chain and also detected signals.
Detailed specifications of rack and individual equipment are given below.
1.0
GENERAL DETAILS:
1.1 Complete equipment, wiring and other details are to be worked out by the bidder.
The details of equipment to be installed in this rack by the bidder is to be provided.
1.2 All audio/video lines from the Jacks & Equipments are to be connected to a
terminal block to be located near the bottom of the rack for external feeding of cables
by the indentor. All the equipment are to be properly earthed with the existing
equipment earthing system in the transmitter hall.
1.3 RFI/EMI filter should be provided at mains input of the rack as per relevant
provisions of FCC rules and regulations, or equivalent standards for effective
rejection of the interference from the high power transmitters operating in the
premises. These racks will be used in High Power Transmitter halls i.e. the rack with
full complement of equipment as to operate in a high RF field. As such all the
specifications of the individual equipment as well as the full chain, are to remain valid
in high RF fields.
2.0 EQUIPMENT RACK:
The standard 19” rack will have various equipment. The frame of the rack should be
of high quality extruded aluminium or high grade steel material as per relevant
material codes. The aluminium profiles should be either anodized or powder coated
and the steel parts should be enameled to give pleasing and aesthetic look and
superior and long lasting paint finish. The rack is to be of sturdy design. The width
should be suitable for mounting of standard 19” equipment. Doors should be
provided on the rear side and should have louvers and exhaust fan to facilitate proper
ventilation. The overall size of rack should be 2000 (H) x 545 (W) x 600 (D) mm.
2.1 Input/Output Isolation
:
90 dB
2.2 Input/Input Isolation
:
90 dB
II.
SPECIFICATIONS OF VIDEO EQUALIZING DISTRIBUTION
AMPLIFIER:
1. The system should be high-performance, having high reliability of professional
quality, analog video equalizing distribution amplifier.
2. It should be have high quality mounting frame for mounting it in standard 19” rack.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 40 of 118 3. It should be capable of amplifying composite and component analog PAL signals,
with or without sync and subcarrier signal.
4. The amplifier must have adjustable gain in the range ± 3dB.
5. The amplifier should have at least 8 outputs and one differential input.
6. It should have redundant power supply.
7. Technical Parameters-
III.
Srl. No.
1.
Description
Power supply
2.
3.
4.
5.
6.
7.
8.
9.
Operating Temperature
Input level
Input Impedance
Input coupling
CMRR
Input Return loss
Output Isolation
Frequency Response
10.
Equalizing Response
13.
S/N ratio
Parameters
230VAC±10%,
50Hz.
0ºC to 45ºC
1 Vp-p nominal
75Ω
DC
>65
>45dB
>40dB
±0.05dB (DC to
10MHz)
±0.05dB (DC to
5MHz)
>70dB
SPECIFICATIONS OF VIDEO AUDIO SWITCHER
1. The Video Audio switchers should consist of a video switching module & audio
switching module with a Control logic board for audio to follow video operation
with basic configuration of 10 inputs and 2 outputs (10x2).
2. Buttons per cross point Control lines should be available to permit Control from
front panel through illuminating momentary push button.
3. Switching should be selectable between instantaneous (non vertical intervals) or as
vertical interval reference.
4. The audio, video and power supply connection should be on the back side of the
unit. The switcher should have following technical specifications.
S.
No.
1.
Description
Specification
Standard
PAL colour standard
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 41 of 118 2.0
2.1
2.2
2.3
2.4
3.0
3.1
3.2
3.3
3.4
4.0
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
5.0
5.1
5.2
5.3
5.4
Video inputs
No. Of inputs
Input signal
level
Input
impedance
Return loss
Video outputs
No. of outputs
10 Nos. with loop through facility
1V p-p nominal (CCVS)
High impedance for loop through inputs, terminable into
75 Ohms through termination plug.
Better than 40dB unto 5 MHz, across 75 Ohms
a) 2 (Two) buffered output
b) 2 for monitor bus
1V p-p nominal (CCVS)
Output signal
level
Output
Ohms 75 Unbalanced
impedance
Isolation
Better than 35 dB
between
buffered output
Video Performance
Gain
Unity, +/- 1.0 dB adjustable(internally)
Frequency
+/- 0.1dB for DC to 5 MHz
response
+/- 0.5 dB from 5 MHz to 8 MHz
Differential
Better than 0.3%
Gain
Differential
Better than 0.3 deg
Phase
Line frequency 0.5%
tilt
Field frequency 0.5%
tilt
Signal to noise Better than 75 dB (weighted) at rated input & output
ratio
levels
Cross talk
Better than 60 dB referenced to 1V p-p at 5 MHz
Connectors
BNC ( for inputs & outputs)
Audio inputs
No. of inputs
10 Nos balanced
Inputs signal
+8dBm nominal, +20 dBm maximum at 600 Ohms
level
Input
600 ohms, Balanced
impedance
Input connector XLR female
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 42 of 118 6.0
6.1
6.2
6.3
6.4
7.0
7.1
7.2
7.3
7.4
7.5
7.6
9.0
9.1
9.2
9.3
9.4
9.5
Audio outputs
No. of outputs
02 (Two) for program & 2 for monitor bus
Output signal
+8 dBm nominal
level
Output
600 Ohms balanced
impedance
Output
XLR male
connectors
Audio Performance
Gain
Unity, +/- 1.5dB adjustable
Frequency
+/- 0.1 dB (20Hz to 20KHz)
response
Cross talk
Better than 70 dB (20 Hz to 15 KHz)
Signal to noise 90 dB referenced to +8dBm
ratio
Harmonic
Better than 0.1% (20Hz to 20KHz at +20dBm)
distortion
Control
Push button Control on front panel
General
Power supply
Operational on both 24 Vdc and 230 Vac +/- 10% @ 50
Hz
Operating
0 deg.C To 45 deg. C
temperature
Storage
-30 to 60 deg. C
temperature
Relative
95% at 40 deg. C (non condensing)
humidity
Dimensions
3U height 19 rack mount chassis
IV. SPECIFICATIONS OF AUDIO JACK PANEL-(N/C) 2x24
The jack strips of 20 points each must be of high quality with positive contact and of
twin type for stereo/mono signals. All the contacts should be silver plated.
V.
VI.
1.0
SPECIFICATION OF VIDEO JACK PANELS: The jack strips of 20 points
each must be of high quality. All the contacts should be silver plated.
SPECIFICATIONS OF AUDIO STEREO MONITORING AMPLIFIER 8 W
TECHNICAL SPECIFICATIONS:
The amplifier should essentially have the following features:
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 43 of 118 1.1
Protection against current over-loads:
The amplifier output should get muted in case of overload and revert to normal
functioning once overload ceases to exist.
1.2
Protection against thermal overload:
Temperature of power pack and heat sinks of both channels should be monitored
and the amplifier should get muted with a visual indication whenever temperature
exceeds permissible limits. In case of excessive temperature of heat sinks, the
amplifier should be protected.
1.3
Monitoring amplifier output should be continuously monitored for DC
components or very low frequency components which might endanger speakers if
present for longer durations. Amplifier output should get blocked in such an
eventuality.
1.4
The amplifier should have protection against open circuit, full short circuit,
ultrasonic frequencies and high RF fields.
1.5
It should be switchable to stereo and dual mono operating modes.
1.6
Necessary function switches such as volume/gain control, low and high filters
should be available on front panel. These controls should be rugged and reliable.
SNo. TECHNICAL
PARAMETER
1.1
INPUT
No. of input (stereo)
1.2
SPECIFICATION
1 set (2 mono)
(XLR female connectors)
-10 dBu to +10 dBu for rated output.
>10 k ohms (balanced)
>60dB
8 W rms (40 W peak music power) per channel at 8
ohms nominal impedance at suitable terminals.
1.3
1.4
1.5
2
Input level
Input impedance
CMRR (20 Hz-20 kHz)
Power Output
2.1
Frequency Response
With reference to 1 kHz over
±0.5 dB
the entire range of 20 Hz to 20
kHz.
Total Harmonic Distortion at 1 <0.5% at rated output
kHz.
Signal –to-noise-ratio
2.2
2.3
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 44 of 118 2.4
2.5
2.6
2.7
2.8
2.9
3.
VII.
With input shorted and at rated Equal better than 85 dB
output (unweighted rms) at
.dBu input (22 Hz-22 kHz)
Damping factor
>75 into 8 ohms at < 1 kHz
Power supply
The amplifier shall work on 230v ± 10%, 48-52 Hz
single phase AC supply.
Level difference between the
Equal to or less than 0.5 dB
channels
Phase difference between the
< 10°, 20 Hz to 20 kHz
channels
Inter-channel X-Talk at 15
>75 dB at nominal level
kHz
Accessories
All necessary accessories like
power cord and mating
connectors shall be supplied
along with the units. The
standard accessories should be
clearly mentioned in the
quotation. Also, optional
accessories if considered
useful / recommended by the
supplier should be quoted
separately.
MECHANICAL:
The amplifier should be 19” rack mounting type for mounting in a rack.
SPECIFICATIONS OF AUDIO DISTRIBUTION AMPLIFIER WITH
SUITABLE FRAME AND REDUNDANT POWER SUPPLY AND
EXTENDER CARD
1. The system should be high-performance high reliability, analog audio distribution
amplifier.
2. It should be of professional quality.
3. It should have flat frequency response a controlled roll-off and very low distortion.
4. The Isolation between the modules must be better than 90dB for audio frequency
band.
5. The amplifier should be configured to 8 outputs designated to one input.
6. It should have balanced input and output.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 45 of 118 7. Technical ParametersS. No. Description
Power supply
1.
Operating Temperature
2.
Input level
3.
output Impedance
4.
Output level
5.
CMRR
6.
Cross talk
7.
Output Isolation
8.
Frequency Response
9.
Gain Range
10.
S/N ratio
11.
VIII.
Parameters
230VAC±10%, 50Hz.
0ºC to 45ºC
28dBu (Maximum)
66Ω
25dBu (Minimum)
>85dB
>85dB isolation
>70dB
±0.05dB (20Hz to 20KHz)
-90 to 30dB in 0.5dB steps
>90dB
SPECIFICATIONS FOR AUDIO PROCESSOR
1. Introduction.
1.1 It should be a high quality stereo/dual mono audio processor for Analog television
audio, but should have digital signal processing only.
1.2 The transmitters should be rugged, reliable and stable in operation under Indian
tropical condition. The climate may vary from very cold to hot, humid & dusty.
1.3 It should provide at it’s output sound with good loudness control as well as preserve
the frequency balance of original sound while controlling subjective loudness.
1.4 It has to process audio available in the transmitter from a professional IRD (Satellite
receiver) or a T.V. studio.
1.5 LCD/LED type meters on front panel for adjustment of parameters as well as for
displaying required parameters for monitoring.
1.6 It should be a stand alone unit with built in tone generator for standard audio test
tones upto 15kHz.
1.7 As the audio processor will be installed in very high R.F. field environment of 10kW
UHF T.V. Transmitters, it should have proper R.F. Shielding.
1.8 The bypass test facility of the unit must be available.
1.9 The detailed technical specifications are provided below:
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 46 of 118 Technical Specifications of Audio Processor
Audio Processor must have the following specifications:
2. Analog Audio Input
2.1 Configuration: Stereo / Dual-Mono.
2.2 Impedance: > 10k Ω load impedance, electronically balanced.
2.3 Nominal Input Level: Software adjustable from –4.0 to +13.0 dBu (VU).
2.4 Maximum Input Level: +27 dBu.
2.5 Connectors: Two XLR-type, female, EMI-suppressed. Pin 1 chassis ground, Pins 2
(+) and 3 electronically balanced symmetrical.
2.6 Processing: Digital Signal Processing (DSP).
2.7 Filtering: RFI filtered.
3 Analog Audio Output
3.1 Configuration: Stereo, Flat or pre-emphasized at 50 μs.
3.2 Load Impedance: 600 Ω, balanced or unbalanced.
3.3 Output Level (100% peak modulation): Adjustable from –6 dBu to +24 dBu peak,
into 600 ohm, software adjustable.
3.4 Signal to Noise Ratio: ≥ 90 dB unweighted (Bypass mode de-emphasised, 20 Hz-15
kHz bandwidth, referenced to 100% modulation).
3.5 L/R Crosstalk: ≤ -70 dB, 20 Hz-15 kHz.
3.6 Distortion: ≤ 0.01% THD (Bypass mode, de-emphasised) 20 Hz-15 kHz bandwidth.
3.7 Connectors: Two XLR –type, male, EMI-suppressed. Pin 1 chassis ground, Pins 2
(+) and 3 electronically balanced, floating and symmetrical.
3.8 Filtering: RFI filtered.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 47 of 118 4. General Parameters
4.1 Input Voltage: Single phase, 220Volt (rms) ± 15%, 50Hz.
4.2 Input Power Connector: IEC, EMI-suppressed. Detachable 3-wire power cord
supplied.
4.3 Grounding: Circuit ground should be independent of chassis ground, and can be
isolated or connected.
4.4 Safety Standards: As per latest international standards.
4.5 Operating Temperature: 0ºC to 45ºC for all operating voltage ranges.
4.6 Humidity: 0 to 95% RH, non-condensing.
4.7 Mounting: 19" Rack mounting, height must be specified by bidder in RU.
4.8 RFI / EMI: According to latest International standards.
4.9 Weight: Must be specified by bidder in Kg.
IX.
AUDIO PATCH CORDS (2ft)
10 nos. of stereo patch cords are to be provided for patching purposes. Their length is to be 2
ft. and should be of high quality, durable audio cable and jacks and match with AF jack
panel.
X.
VIDEO PATCH CORDS (2 ft)
10 nos. of video patch cords are to be provided for patching purposes. Their length is to be 2
ft. and should be of high quality, durable video cable and jacks and match with video jack
panel.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 48 of 118 Annexure I-5
I. SPECIFICATIONS OF WAVEFORM MONITOR
Scope:
1.
Doordarshan Requires 2 Input (A&B) Analog waveform monitors for its TV
Transmitters. These waveform monitors will be as per the technical specifications of
Doordarshan. The waveform monitors should be rugged, reliable and stable in
operation.
1.1 The Waveform monitors should be quoted with product’s detailed specifications
datasheet pamphlets & operation Manual. It will be the responsibility of the bidder to
ensure that the equipment is complete in all respects. All connectors and cable etc
required for taking measurements should be supplied with the equipment
2. TECHNICAL SPECIFICATIONS of Waveform Monitor
2.1. The waveform monitor must offer the performance monitoring and measurement
capabilities of Analog composite video formats.
2.2. The instrument shall have dual Input monitoring facilities.
2.3. It shall provide facilities for monitoring of single H pulse and dual H pulse and
monitoring of VITS signals.
2.4. The instrument should have the facility for monitoring of link A or B and
combined input with a comprehensive set of displays and status report tools.
2.5. The monitor should be capable to maintain correct timing between links A & B.
2.6. The Technical Specifications are given below:
S.No
2.6.1
2.6.2
2.6.3
Parameter
Format
Input Dynamic Range
Return Loss
2.6.4
2.6.5
2.6.6
2.6.7
Cross Talk
Loop through Isolation
Max operating amplitude
Vertical measurement
Accuracy
Gain
Frequency Response (0 to
5.5MHz)
Sweep Time Accuracy
Sweep Linearity
2.6.8
2.6.9
2.6.10
2.6.11
Required Performance
PAL
±6dB
35dB (Power OFF)
40dB (Power ON)
>60dB
>70dB
1.8V to 2.2V, DC + peak AC
±1% all gain settings
In the multiples of 1, 2, 5 & 10.
±1%
±0.5%
0.2% of time displayed on screen.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 49 of 118 3 General Requirement:
3.1
Test Certificate of the instrument shall accompany each instrument on
delivery
3.2
The Equipment should have minimum 1 no. USB 2.0 Port.
USB port should support USB flash drives/ connection to PC.
3.3
The Software for PC Communications should be provided to work
between a Windows PC and the waveform monitor via USB. It should be
able to Transfer and save settings, waveforms, measurements and screen
images.
Matching cables must be supplied with each equipment.
3.4
The Waveform monitor must have BNC (female) input connectors. It
should also have the facility loop through of video signal to monitor it on
the video monitors.
3.5
Power Supply
The Oscilloscope shall work on 220V+10%, 50-60 Hz
AC supply. The power supply unit of the equipment
shall be protected against overload short circuit and
over-voltage etc.
3.6
Environmental
The equipment shall be capable of performing
satisfactorily in the temperature range from 0 deg Cel
to 45 deg Cel and humid conditions of 85% at 40 deg
C.
4.0 ACCESSORIES
All the essential accessories also to be included in the offer.
II. SPECIFICATIONS OF VU METER
Specification for VU meter
1. It should be a stand alone unit, simple to operate and 19” rack mount.
2. It must be a professional level monitoring in broadcast systems.
3. The unit should have at least two Analog input (XLR type) and also have facility
to measure digital input signals (AES/EBU).
4. The input range must be at least ±10dB.
5. Unit should have the facility of internal speakers.
6.
Technical Specifications:
Srl. No.
Description
Parametric value
Input Impedance
600 ohm.
6.1
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 50 of 118 6.2
Maximum Input level
20dBU.
6.3
Frequency of operation
20Hz to 20KHz.
6.4
Accuracy
±1dB.
6.5
Distortion
<0.1%.
6.6
S/N Ratio
≥80dB.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 51 of 118 Annexure I-6
SPECIFICATIONS OF INSTALLATION MATERIALS:
1. All the installation material like Cables and Connectors must be of high quality, used
for broadcasting system for a good transmission performance.
2. The VSWR of all RF feeder components must be less than 1.05.
3. There should have a firm grip between various coaxial feeder components at the time
of installation.
4. The power cables should be capable to handle the power supplied to it.
5. The impedance of the RF Cables should be as per their specified nomenclature.
6. All the installation material must be of reputed make.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 52 of 118 Annexure I-7
SPECIFICATIONS OF COMPUTER WITH 1 KVA UPS AND LASERJET
PRINTER:
1.0 Scope: Doordarshan (DD) intends to procure Computer system based on latest
technology. The computers should be rugged, reliable, and stable in operation under very
cold to hot, humid and dusty environmental conditions. Detailed specifications of the
Computers are given in this document. The Computers will be supplied along with
Uninterrupted Power Supply (UPS) and Laser printer. The computer manufacturer /
bidder must have his local office / representative in India.
1. 1 Computer Configuration
S.No.
Description
Specification
Intel Core 2 Duo 2.93 Ghz or better, 3MB L2
a.
CPU
cache and 800 MHz FSB
Intel 3 series/nVidia GForce 7 series or better on
b.
Chipset
OEM Motherboard
Integrated Graphics, 2 PCI, 1 PCI Express x 1 and
c.
Bus Architecture
1 PCI Express x 16
2 GB 667 MHz DDR2 RAM with 4GB
d.
Memory
Expandability
500 GB 7200 rpm Serial ATA HDD
e.
Hard Disk Drive
48.2 cm (19 inch) TFT Digital Colour Monitor
f.
Monitor
TCO-03 certified
104 keys
g.
Keyboard
Optical
h.
Mouse
4 Nos. (2 Nos. 5.25 inches for Optical Media
i.
Bays
Drives and 2 Nos. 3.5 inches for Hard Disk
Drives)
6 USB Ports (with at least 2 in front), 1 Serial
j.
Ports
audio ports for microphone and headphone in
front
Mini tower
k.
Cabinet
16X
or better DVD ROM Drive
l.
DVD ROM Drive
10/100/1000 on board integrated Network Port
m. Networking
with remote booting facility remote system
facility
installation, remote wake up
n.
Operating System Windows Seven professional preloaded with
Media and Documentation and Certificate of
Authenticity
Win Logo Seven professional OS and Linux
o.
OS Certifications
Certification
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 53 of 118 p.
Power
Management
q.
Preloaded
Software
Screen Blanking, Hard Disk and System Idle
Mode in Power On, Set up Password, Power
supply SMPS Surge protected
Norton, McAfee, or equivalent Antivirus (Latest
Version) with 360 days License and open office
2. Laser Printer
S.No. Description
Specification
a
Output Type
Black and White
b
Resolution
600 x 600 dpi
c
Page per Minute(PPM)
16
d
Paper size
A4
e
Interface
USB 2.0
f
Necessary cables & Utility Software
3.0 1000 VA UPS
S.N Description
o
Capacity
a
b
Output waveform
c
Voltage on Mains
d
Frequency(Input)
e
Backup time
f
Frequency(on Battery)
g
Transfer Time
h
Over Load Indication
i
Charger
j
k
Short circuit protection
Protection
l
Battery
Specification
1000 VA
Stepped approximation to a Sinewave
100 - 265VAC
47 - 53Hz
20 minutes
50Hz + / - 1%
<20 milli seconds
100% for 60 seconds, Indications Via LED & Audible
alarm with 3 times restart
Constant Power, 2 step charging Input voltage range 100
- 270V
Multiple short circuit protection provided
Overload, short circuit, low battery Over charge, Main
slow & High input voltage
Sealed Maintenance free Cold Start, No-load AutoShutdown
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 54 of 118 Annexure I-8
SPECIFICATIONS OF 10 KW DUMMY LOAD
1. Introduction: One number 10 kW air cooled Dummy Load of 50 Ohm, is required
for transmitter at Rajauri (J&K) with the following features:
1.1 Low maintenance and high reliability.
1.2 Fully shielded against the production of extraneous radiation.
1.3 Manual / Automatic fan modes.
2. Technical specifications:
S.No. Description
2.1
2.2
2.3
2.4
2.5
2.6
2.7
Power Rating
Connector
Frequency Range
VSWR
Impedance(Nominal)
Load Coolant
AC Power
2.8
2.9
2.10
2.11
Temperature of Storage
Temperature of Operation
Humidity
Dimensions: (Length x Width
x Depth) in mm.
Weight (in kg)
2.12
Technical Specification
10 kW continuous RMS power
3⅛” EIA UnFlange
470 to 862 MHz
< 1.10:1
50 Ohm Nominal
Forced Air cooled
Single Phase, 230 volts(rms) + 10%,
50 Hz + 4%
-30ºC to 50ºC
0ºC to 45ºC
95% NC
To be provided by the bidder.
To be provided by the bidder.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 55 of 118 Annexure I-9
SPECIFICATIONS OF MEASURING EQUIPMENT:
I.
SPECIFICATIONS OF COLOUR TEST PATTERN & TONE
GENERATOR
1. Doordarshan requires broadcast quality colour test pattern and tone generator with test
signals for analog TV transmitters.
2. It should work for PAL/625 line system.
3. The unit should have SNMP remote control facility to integrate automated service.
4. Technical parametersSrl. No.
Description
Parametric values
Power supply
230VAC±10%, 50Hz
4.1
Output Connector – video/audio
BNC/XLR
4.2
Operating Temperature
0ºC to 45ºC
4.3
Output Impedance - video/audio
75Ω/12 Ω
4.4
Video Output Return loss
>30dB
4.5
Video Test signals
75% & 100% colour bar,
4.6
linearity, flat field, Multiburst,
sweep, pulse & bar etc.
Audio Level
-48dBU to +12dBU (Resolution
4.7
1dB)
II.
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
SPECIFICATIONS OF T.V. ANALYSER/DEMODULATOR
TV Demodulators are required for measurements and monitoring the quality of
transmission of the TV Transmitter. The detailed technical specifications are given
blow:
GENERAL
It should be capable of operation in TV band IV, V(470 MHz to 860MHz). (
CCIR PAL G )
Channel change should be possible by DIP switch / Hex switch or
Electronically by push buttons.
It should have capability for RF and IF measurements.
It should have zero reference pulse facility to measure visual modulation
depth.
It should have switch selected sound trap ‘ON’ & ‘OFF’ facility.
It should have switch selected envelope detection & synchronous detection.
It should have squelch for noise suppression in case of absence of sound
carrier failure.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 56 of 118 2.0
2.1
2.2
INPUTS
RF Input, impedance
RF Input voltage
2.2.1 RF Input voltage selection range
with 30 dB attenuation
2.2.2 RF Input voltage selection range
with 15 dB attenuation
2.3
2.4
2.5
RF Input Return loss
IF Input Connector & impedance
IF Input level
2.6
2.7
3.0
3.1
IF Input Return loss
Gain control facility
OUTPUTS
Video Output Connectors &
impedance
3.2
Video Output level
3.3
3.4
Video Output Return loss
Sound Output Connectors
3.5
Sound Output level (at 30 KHz
deviation and F mod=500 Hz)
Sound Output Source impedance
3.6
BNC female connector, 50 Ohms
Two switches are required for selection
of input voltage ranges for RF input
(a) 300 mV to 3.0 V (sync. Peak)
(b) 0.5 dBm to 20.0 dBm (rms black
picture)
(a) 80 mV to 800 mV (sync. Peak)
(b) -10 dBm to +8 dBm (rms black
picture)
> 15 dB
BNC female, 50 Ohms
(a) 5 mV to 150 mV (Sync) Peak)
(b) -30 dBm to -3 dBm (rms black
picture)
> 20 dB
Manual or Automatic: is to be specified
(a) Two BNC female outputs are
required
(b) 75 Ohms
1 Volt peak to peak (adjustable + 1.5
dB)
> 20 dB (from 0 to 5.0 MHz)
Two outputs with 3 Pin XLR female
connectors
+6 dBm +/- 0.5 dBm across 600 Ohms
(adjustable +/- 3 dB)
< 30 Ohms
4.0
4.1
4.1.1
4.1.2
4.1.3
Display Indications On Front Panel
A Bar graph display is required for indications.
RF level indications
(i) Low (ii) Normal (iii) High
IF level indications
Within normal
Frequency deviation
0 to 50 KHz (linear)
(after de-emphasis).
4.1.4 There should be a facility available for the selection of RF, IF & frequency
Deviation indications on the front panel.
5.0 Transmission Characteristics
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 57 of 118 5.1 Specifications for Video Channel
5.1.1 Amplitude Vs frequency response
5.1.2 Group delay vs frequency
characteristics
5.1.3
5.1.4
5.1.5
5.1.6
5.1.7
5.1.8
5.1.9
Differential gain
Differential phase
Tilt at 50 Hz
Luminance bar amplitude error
Base line distortion
2T amplitude error
Signal to noise ratio
(At an input level of 10 dBm)
6.0
6.1
6.2
Sound Channel
Inter carrier frequency
Frequency response
6.3
Harmonic distortion
(At 50 KHz deviation and F
mod=500 Hz)
Inter-carrier S/N ratio (At 50KHz
deviation)
Power Supply
Dimensions/Weight
Mounting
Temperature for operation
Relative humidity
Max Altitude
6.4
7.0
7.1
7.2
7.3
7.4
7.5
(a) +/- 0.5 dB from 100 KHz to 4.43
MHz (with sound trap)
(b) +/- 0.5 dB from 100 KHz to 5.0
MHz (without sound trap)
a) +/- 30 ns upto 4.43 MHz (with sound
trap)
b) +/- 15 ns upto 5.0 MHz (without
sound trap)
< 3%
< ±2 deg.
< 2%
< 2%
< 2%
< 5%
> 55dB
5.5 MHz
+/- 1.0 dB wrt 50 μs de-emphasis from 50
to 15 KHz
< 1%
> 55 dB
230 V +/- 10%,50 Hz, single phase
To be mentioned by the supplier
19” Rack mountable
0 degree to 45 degree centigrade
90%
3500 Meter.
The TV demodulator must be supplied with Mounting Arrangement Hardware (19” Rack
Mount Kit) and all other standard Cables and other accessories.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 58 of 118 III.
Specification of Digital storage, 2 Channel 100 MHz Oscilloscope
Scope:
1.0 Doordarshan Requires 100 MHz 2 Channel Oscilloscopes for its TV Transmitters.
These oscilloscopes will be as per the technical specifications of Doordarshan. The
oscilloscope should be rugged, reliable and stable in operation.
1.1 The oscilloscopes should be quoted with product’s detailed specifications datasheet
pamphlets & operation Manual. It will be the responsibility of the bidder to ensure that
the equipment is complete in all respects. All connectors and cable etc required for taking
measurements should be supplied with the equipment
2.0 TECHNICAL SPECIFICATIONS of 100 MHz OSCILLOSCOPE
The instrument shall have dual channel measurement facilities. It shall provide facilities
for measurement of rise time, fall time, positive width, negative width, frequency, period,
mean, cycle RMS, minimum, maximum, peak to peak etc. It shall provide facilities for
automatic measurements of peak to peak voltage, frequency, period, rise time and fall
time functions.
S.No
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
Parameter
Bandwidth
Vertical Operating Modes
Deflection Accuracy
Sensitivity
Rise Time
Channel to Channel CMR
Maximum Input
Input Coupling
Input Impedance
2.10
1
2
3
HORIZONTAL SYSTEM
Sweep display modes
Sweep Mode
Time base Accuracy
4
5
5(a)
5(b)
Range
X-Y Mode
X-axis BW
Y-axis BW
Required Performance
DC to 100 MHz (at- 3dB)
CH1, CH2, Add, Subtract and FFT
3% or better
5mV/Div to 5V/Div in steps
less than or equal to 3.5n sec
At least 100:1 at 60Hz
300V rms Cat. II;
AC, DC and Ground
1 MΩ ± 2% in parallel with 20 pF ±3 pF
Y-T and X-Y mode
Auto, Normal and Single Sequence
50 PPM
5 ns/div to 50 sec/div
DC to 100 MHz
Same as for the vertical system
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 59 of 118 2.11 TRIGGERING SYSTEM
1
Source
2
Trigger Operating modes
3
Time Base Range
4
Trigger Coupling
2.12
5(a)
Triggering Types
Edge
5(b)
Video
5 (c ) Pulse Width
CH1, CH2, AC line & external
Auto Normal & Single Sequence
5ns/div to 50 sec/div
AC, DC , HF reject & LF reject, Noise
Reject
Conventional level driven trigger.
Positive or negative slope on any channel
coupling selection
Trigger on all lines or individual line, odd/
even or all fields from composite video, or
broadcast standards (NTSC, PAL,
SECAM)
Trigger on a pulse width less than, greater
than, equal to, or not equal to a selectable
time limit ranging from 33 ns to 10 sec
2.13 DIGITAL STORE SYSTEM
1
Real time Sample Rate 500 Mega samples per second per channel
maximum
(simultaneously in both channels)
2
Acquisition Modes
Average, Sample and Peak detect (
Minimum 75 MHz analog BW)
3
Resolution
Vertical 8 bit
4
Record Length/memory
Upto 2500 points or more per channel in
dual channel mode
5
Memory
2 Waveforms
10 front panel setups
6
Display refresh rate (Update 180 waveform/sec
rate)
2.14 CURSORS READOUT
1
Cursor measurement
[Δ]T, 1[Δ]T (frequency), [Δ]V.
2.15 ACCESSORIES
1
Power cord/ probes etc.
2.16 DISPLAY
1
Display
Power
Cord
=
1no.
Probe (10:1) = 2 Nos. (1 no. per Channel).
And any other connectors required for
normal functioning of the Oscilloscope.
LCD
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 60 of 118 2
Type
Rectangular
3
Useful Display area
8 cm x 10 cm
4
Interpolation
Sinx/x
2.17 GENERAL
1
Test Certificate of the instrument shall accompany each instrument on
delivery
2
The Equipment should have minimum 1 no. USB 2.0 Port.
USB port should support USB flash drives/ connection to PC.
3
4
5
6
The Software for PC Communications should be provided to work
between a Windows PC and the oscilloscope via USB. It should be able to
Transfer and save settings, waveforms, measurements and screen images.
Matching cables must be supplied with each oscilloscope
Autoset menu
Single - button, automatic setup of all
channels for vertical, Horizontal and
trigger systems with undo autoset.
Power Supply
The Oscilloscope shall work on
220V+10%, 50-60 Hz AC supply. The
power supply unit of the equipment shall
be protected against overload short circuit
and over-voltage etc.
Environmental
The equipment shall be capable of
performing
satisfactorily
in
the
temperature range from 0 deg Cel to 45
deg Cel and humid conditions of 85% at
40 deg Cel
2.18 ACCESSORIES
All the essential accessories such as probes, carrying case etc. are also to be included in
the offer.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 61 of 118 Annexure I-10
MISC ITEMS FOR MONITORING AND MAINTENANCE:
I. SPECIFICATIONS OF RF STEP ATTENUATOR (0 – 110 dB)
S. No.
Parameters
Values
Frequency Range DC-1GHz
1.
dB Value
0-110 dB in 1dB/10dB steps
2.
(Fine/Coarse steps)
Connectors
BNC
3.
Impedance
50 Ohms
4.
VSWR
1.2:1 (DC-500MHz)
5.
1.4:1 (500MHz-1GHz)
Accuracy
+ 0.2 dB (DC-500MHz)
6.
+ 0.3 dB (500MHz-1GHz)
Insertion Loss
0.5dB upto 1 GHz
7.
Average Power
2 Watt
8.
Peak Power
1000W Peak
9.
Temperature
-10° C to 50° C
10.
II.
SPECIFICATIONS OF RF FIXED ATTENUATOR 3 dB, 6 dB, 12 dB (N type)
S. No.
Parameters
Values
Frequency Range DC-1GHz
1.
DB Value
3dB, 6dB, 12dB
2.
(each one independently)
Connectors
N type
3.
Impedance
50 Ohms
4.
VSWR
1.2:1 (DC-500MHz)
5.
1.4:1 (500MHz-1GHz)
Accuracy
+ 0.2 dB (DC-500MHz)
6.
+ 0.3 dB (500MHz-1GHz)
Insertion Loss
0.5dB upto 1 GHz
7.
Rating
1 Watt
8.
Construction
Rugged unibody
9.
Temperature
-10° C to 50° C
10.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 62 of 118 Annexure I-11
ANTENNA SYSTEM:
I. SPECIFICATIONS OF 10 KW, BAND IV/V UHF SUPERTURNSTILE,
OMNI-DIRECTIONAL, BROADBAND ANTENNA SYSTEM
a) Scope:
1. Doordarshan requires antenna system, self supporting, enclosed in Structural Fiber
Glass Radome to be mounted on top of AIR steel tower AT Rajouri.
2. The antenna will be used for radiating 10KW power in UHF band. The combined
output of two Nos. 5 kW each Transmitter shall be fed to this antenna.
3. The Channel Details of Transmitters are given below.
4. Less weight, Low wind load and de-icing effect of antenna is basic requirement.
5. The Antenna System should be complete in all respect.
b) Details of Channel frequency for operation of the antenna system (Please
refer Para 1.7 of DD specifications):
S.No
1.
2.
Programme
Channel
DD National
DD News
Frequency band
Operating Channel
Frequency
UHF band IV/V (470MHz to Ch# 32(.) PAL- G
862 MHz)
UHF band IV/V (470MHz to Ch# 34(.) PAL- G
862 MHz)
c) Technical Specifications:
S.
Parameter
No.
1.
Type / Configuration
2.
Frequency Range
3.
4.
5.
Power Handling Capacity
Polarization
Horizontal Radiation
Pattern
Permissible limit of:
Variation in the HRP
Value
Vertical Radiation
6.
7.
Specification
Superturnstile, self supporting, top mounted
on Square Steel Tower.
Broadband in UHF Band (470 MHz to 862
MHz). Capable of operation on any channel
in the UHF band.
10 kW
Horizontal
Omni directional.
Maximum + 1.2dB for Omnidirectional.
A typical pattern should be attached, It
should be possible to introduce Beam tilt
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 63 of 118 and Null fill. Typical value of Beam till is
0.5° and Null fill is 10%.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
Net gain of the 'antenna
System' in dBd (with
respect to half wave
dipole) after deducting all
losses in branch feeder
cables, splitters/dividers
etc.
(Formula for Net Gain =
Horizontal Directivity +
Vertical Directivity losses)
horizontal directivity
(dBd)
vertical directivity (dBd)
(a) branch feeder losses
(dB)
(b) splitter losses (dB)
(c) beam tilt losses (dB)
(d) null fill losses (dB)
Input impedance
VSWR of the whole
Antenna System
Not less than (minimum) 11 dBd for Omni
directional antenna system, at midband
frequency 666 MHz (with 0.5 deg. beam tilt
and 10% null fill).
The complete information about Net Gain
Calculation as per the formula provided is
mandatory.
Numerical value in dBd must be provided.
Numerical value in dBd must be provided.
Numerical values for all losses in dB must
be provided.
50 ohms
a) 1.10:1 Broadband (Max)
(In the whole UHF band IV & V
frequency range i.e. 470MHz to 862MHz)
b) 1.05:1 at Vision carriers. (
Programme channel wise frequency detail is
given in II above)
3⅛” EIA flange
Input Connector (Single
Input)
Mechanical Characteristics of Antenna System
Maximum wind speed for 216 km/hr (60m/sec)
survival
Provision of Radome
To be provided, details must be given.
Climbing Access
A safe climbing access for antenna for
repairing of antenna system i.e. branch
feeder cables, panels, power splitters and
access to AOL etc. must be available.
Antenna support structure Antenna is to be supplied along with
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 64 of 118 for mounting and hauling
up.
19.
Lightening Protection &
Aviation Light
20.
Antenna System Weight
(Dead Load)
21.
Wind Load
22.
Total Antenna System
height
23.
Accessories required
antenna support structure for mounting and
hauling up, which is to be fixed on top of
square steel AIR towers. Necessary
mounting assembly should also be provided.
(a) A lightening conductor and twin
Aviation Lights (LED Type) with interblinking arrangement at the tower top
should be provided with Antenna support
structure. The aviation lights on tower must
use 24 Volt D.C. power supply. A suitable
length for power supply cable should also be
supplied with lights.
(b) Colour of the radome of antenna system
must be as per ICAO norms.
Total dead weight of antenna system with
radome, support structure etc may be
provided in kg. It should not be more than
500kg.
The wind load of the whole antenna system
with radome support structure etc at wind
speed of 216 km/hr should be provided in
Kg. It should not be more than 750Kg.
The total height of the complete Antenna
System should be provided with detailed
drawing. It should not be more than
5.5meter.
All accessories required for completeness of
the system, should be quoted with the offer.
d) General Instructions:
1. All the relevant technical pamphlets, data sheets drawings, block diagrams list of all
items quoted with description of the functioning of the system should be attached with
the offer, otherwise offer may not be considered for evaluation.
2. The details of past supply for the similar Antenna system should be provided in the
following format:
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 65 of 118 Name and
Postal
Address of
the Firm
where the
antenna is
supplied
Name of the
contact
person with
E mail id
Telephone Make and
and Fax
Model of
Nos.
the
Antenna
System
supplied
Power capacity
of the similar
antenna system
supplied
Quantity
supplied
3. The set of essential spares, modules, tool and other necessary equipment required,
should also be quoted separately with the offer as optional items.
4. A detailed installation, operation and maintenance manuals along with relevant
drawings, pamphlets, data sheet etc should be attached with the offer for analyzing the
technical requirement of Doordarshan. The offer without operation and maintenance
manual will not be considered for analysis and may be rejected with out making any
reference to the firm.
5. The Antenna system manufacturer /bidder must have his local office / representative
in India. The name, contacts, address of local office / representative along with
manufacturer’s authority letter in favour of local representative must be given with the
offer. The local office / representative in India will be nodal point for resolving after
sales issues. In case any module/part of the antenna system requires repairs at factory,
the same would be handed over to local office / representative in India, who would
arrange repairs locally or export the defective modules/part to its O.E.M. and arrange
its repair etc. The repaired item, will have to be delivered by the local representative
at transmitter site in India.
6.
SPARES:- Essential spares required for the maintenance of the antenna system
should also be quoted separately. The value of such spares should not exceed 5% of the total
cost of the equipment. Doordarshan shall exercise option to order spares separately. The spare
cost shall not be accounted for deciding the offer of the main antenna system. The
manufacture shall also give a certificate attached with the offer to supply maintenance support
and all spare during the life time of the Antenna. The life of the Antenna system should be
certified by the manufacturer. This is an essential requirement. The cost of spare shall not be
taken into account for ascertaining the lowest bidder.
7.
ACCESSORIES:- All essential accessories required that shall complete the system
should be include in the offer.
8.
PRICE:- The bidder along with the offer must quote item wise price of all the items,
which constitute the system, separately. A copy of the “price bid” showing/provided all items
of bill of material without showing the prices must be attached with the “Technical bid”.
9.
TECHNICAL LITERATURE:
i. Two sets of technical data sheets of the equipment offered, Installation manuals,
operational and service manual shall be supplied with the each set of antenna system.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 66 of 118 ii. One set of above shall be supplied to this Directorate along with the tender for the
purpose of evaluation.
10. Site Acceptance Test:
After installation of Antenna system, combiner, cable, dehydrator etc., the site acceptance
test will be carried out by DD Engineer, as per the approved ATP.
11.
GUARANTEE:- The antenna system shall be guaranteed against any
manufacturing defects for a period of two years from the date of supply. Any parts
failing damaged during the guarantee period shall be repaired/ replaced free of charge
by the supplier as per specification at the site.
12. The suggestive bill of material required for one Antenna System is provided in
Annexure-I.
13. All items / equipments required for the completeness of the Antenna System should
be quoted and provided with the offer.
14. Break-up of prices of all items/equipment should be provided.
II.
SPECIFICATIONS FOR STRENGTHENING/MODIFICATION
EXISTING 50MTR. AIR FM STEEL TOWER:
1.
2.
3.
4.
5.
6.
The existing 50 M AIR FM Tower at Rajouri may need strengthening
before installation of the antenna and the R.F. feeder cable. Working FM
antennae and their related cables are already installed on the above tower.
The bidder alongwith his tower erection expert may physically inspect the
existing sites and tower, for any other additional information desired for
analysis of tower strength, before submitting their offer.
The bidder has to take care and ensure that the working of FM/Microwave
antennae at existing site is not interrupted or disturbed while inspecting the
tower for submitting the bids.
No shut down of any running transmission service shall be carried out for
inspection for submission of bid.
The work for modification of tower is to be carried out preferably in the
night time after shut down of the main services at these sites.
AIR and Doordarshan sites are prohibited areas and hence entry to their
premises is through security pass only which is issued by competent
authority at the concerned stations. The bidder may contact the Station
Engineer AIR FM Rajouri and get the passes issued for their staff/workers
for inspection. Entry Passes would have to be got issued for execution of
work by the successful bidder separately.
DGDD/TxD/5kWHPT Specs/J&K/2010 OF
Page 67 of 118 7.
The job related with strengthening of AIR FM Tower includes:
(a) Preparing separate drawings after analyzing the exact requirement of
strengthening for bearing the loading of tower due to new antenna system
and RF feeder cable.
(b) Designing, fabricating, supplying, modifying and erecting necessary
members, interface, nuts, bolts, washers, etc. on the tower for its
strengthening as per the analysis and structural requirement.
(c) Carrying out necessary modifications in the tower section, members and
top interface required to install the UHF panel type dual feed antenna on the
top of the tower.
(d) The drawings and analysis for modifications/strengthening of towers are to
be got approved by Indian institute of Technology at Chennai/ Delhi/
Mumbai/ Kanpur/ Roorkee/Indian Institute of Science Bangalore/Structural
Engineering Research Centre, Chennai. The copy of the approval has to be
submitted to AIR Directorate before the work is taken up at site.
8.
General Instructions regarding strengthening of air Tower are given
below:
(a) Bidder shall be fully responsible for soundness of the modified design of
tower, fabrication of necessary sections and fasteners etc., SITC of (1+1)
TV Transmitters, including installation of antenna, R.F. cable, combiner,
dehydrator, electrical works, earthing etc. besides the transmitters, and
safety of the complete turnkey project.
(b) The bidder shall complete and include all minor/major items of
appurtenances and accessories which may not have been enumerated in this
specification and BOM but which are useful and necessary for ensuring
strengthening of tower and installation of antenna, R.F. cable, combiner,
dehydrator in all respects and complete the turnkey project as per good
engineering practices and no extra charges will be paid for providing and
installing such minor/major items.
(c) Prior approval of the purchaser, in writing, shall be obtained from DG:AIR
if the bidder desires to sublet or assign any section of the work associated
with the fabrication, work related with strengthening of tower etc. Such
permission of consent shall not, however discharge the bidder from his
liabilities in this contract or any part thereof.
(d) The bidder shall make his own arrangements for power supply, water and
the storage of materials and their safe custody at site for the entire turnkey
project.
(e) Bidder shall make good all damage to the purchaser’s building, property,
equipment etc. how-so-ever arising from the project and in the course of
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 68 of 118 such work and throughout the period during which the safety of tower and
other property of the purchaser is guaranteed.
(f) The bidder shall indemnify and hold harmless the purchaser against any
claims in respect of damages to building, property situated nearby, not
belonging to the purchaser, how-so-ever arising from the strengthening of
the tower work and in course of such work and throughout the period during
which the safety of tower is guaranteed.
(g) The bidder shall indemnify and hold harmless the purchaser against claims
in respect to injury any mishap to any person how-so-ever arising out of the
tower related work and throughout the period of turnkey project, during
which the safety of the tower is guaranteed.
(h) The bidder shall discharge all obligations under the Indian workmen’s
compensation act any local, state laws and regulations in so far as it affects
the workmen in his employment.
(i) The bidder shall make his own arrangement for employing labour, skilled &
unskilled, and shall make his own arrangement for providing
accommodation for his workmen at site or elsewhere.
(j) The bidder shall hold the purchaser and his employees safe, harmless and
immune from any liability that may arise out of infringements of patents and
copyright associated with design, fabrication and modification in tower.
(k) The specifications indicated herein are only to guide the bidder about the
requirements of the purchaser. Detailed analysis and design for
strengthening of the tower from all aspects shall be got worked out by the
bidder, keeping in view the effects of local meteorological conditions like
wind velocity, seismic zone, temperature, latest codal provisions and as per
good engineering practice to ensure the safety of the tower. Tender shall
consult Wind & seismic zones as per latest BIS codes. The bidder may also
consult structural engineer(s)/structural engineering institute regarding the
modifications in tower for the new antenna system. Only Indian codes are
acceptable for the work of strengthening of existing towers.
(l) Detailed information concerning design parameters such as loads due to
wind effect as per IS:875-1987 and seismic effect as per IS:1893 – 2002
with latest amendments, dead loads, antenna loads, loads combination
considered, design philosophy along with other information and shall
contain the following:
i. Wind speed zone, terrain category, topographic factor etc.
ii. Seismic zones factor, importance factor, response reduction
factor etc.
iii. Antennae loads due to proposed TV antenna, FM, MW dishes or
any other communication or broadcast antennae installed on
tower.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 69 of 118 iv. Load combination considered. Design criteria, analytical model
& philosophy.
v. Deflection at top of tower including UHF antenna system and
reaction at base in most critical load combination.
vi. Detailed information about material used in sections &
accessories such as quality of steel, fasteners with reference to
relevant BIS codes.
vii. Details of aviation light, type model, battery back up, sun switch,
earthing, lightening arrestor arrangement power cable details etc,
with drawings, catalogues and other information.
(m) The tower shall be checked after incorporating the modifications, for
dynamic effect of wind and seismic forces as per codal provision of
IS:875/part 3-1987 and 1893/2002 with latest amendments, respectively
alongwith static effect.
n) The successful bidder shall supply within two months from the date of the
acceptance of tender the following documents to Doordarshan Directorate
for review:
i. A detailed report alongwith dynamic analysis of the tower, need for
strengthening, method that would be adopted for strengthening.
ii. The certificate testifying the soundness and safety of modifications
suggested in the design of tower at his own cost from one of the following
institutions:
1. Indian institute of Technology at Chennai/ Delhi/ Mumbai/ Kanpur/
Roorkee.
2. Indian Institute of Science Bangalore.
3. Structural Engineering Research Centre, Chennai.
o) The Compliance statement of all the paras mentioned above must also be
submitted in the prescribed proforma, table given in Para 16 may be
referred.
III. SPECIFICATIONS OF AUTOMATIC DEHYDRATOR SYSTEM
S.No. Parameter/Description
Specification/DD’s Requirement
1
(a) The pressurization and dehydrator
Automatic
Dehydrator
(Pressurization) system for the
system should be specified.
4” feeder cable of 85 meter
(b) The detailed specs with make,
length and supplied Antenna
model and data-sheet of the
system. It should provide
Dehydrator should be attached.
pressurized dry air to the system
(C)The sealing compound for sealing
various joints of the Antenna System
and continuously purges the
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 70 of 118 collected moisture to the
atmosphere.
The
offered
Automatic
Dehydrator
(Pressurization)
system should be capable to
provide pressurization of cable
and antenna system with
adequate provision to cover up
small leakage (2 psi in 24 hours)
within
justified
duration.
Detailed data sheet should be
provided
The
offered
Automatic
Dehydrator
(Pressurization
system) have the provision for
adjustment of working pressure
between 2 psig for ON and 7
psig for OFF.
The
offered
Automatic
Dehydrator
(Pressurization
system)
should
have
the
provision for various alarms,
indicators and safety valves for
safety of antenna, cable and
dehydrator systems.
2
3
4
IV.
S. No.
1.
2.
3.
4.
should also be provided.
1.
2.
3.
The offered Automatic Dehydrator
(Pressurization) system should work
on 230 volts 50 Hz AC.
It should be capable to handle the
climatic condition of India.
Detailed data sheet should be
provided
Detailed
provided
data sheet should be
Required features:
1.Low pressure alarm & switch
2.High pressure alarm& switch
3.Pressure gauge
4.Dehydrator pressure switch(Adj.)
5.Visual moisture indicator
6. High pressure safety relive valve.
7. Pressure and humidity monitor.
SPECIFICATIONS OF 2X5 KW, 2 CHANNEL CONSTANT IMPEDANCE
UHF COMBINER
Parameter
FREQUENCIES of UHF band
IV
RATED POWER
INSERTION LOSS
1. Narrow Band
2. Wide Band
Input/Output connectors
Value
Please refer Para 1.7 of DD
Specifications
For combining two 5kW UHF
Transmitters’ power
0.3 dB max at centre freq
0.1 dB max at centre freq
3 1/8” EIA unflanged
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 71 of 118 5.
VSWR/RETURN LOSS
6.
Isolation
1. Narrow band to Wide Band
2. Wide Band to Narrow Band
Input Impedance
Operating Temperature Range
Cooling
Weight
Dimensions
7.
8.
9.
10.
VSWR 1.08:1 at centre
frequency{return loss 28 dB} or
better
VSWR 1.10:1 at other frequencies
{return loss 26dB} or better in the
channel.
30 dB or better
48 dB or better
50 ohm
0 to 45 deg C
Air convection
To be specified by the bidder
To be specified by the bidder
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 72 of 118 Annexure I-12
SPECIFICATIONS OF SEVEN PORT PATCH PANEL
S.No.
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.10
Parameter
FREQUENCY RANGE
INPUT /OUTPUT POWER
INPUT / OUTPUT PORTS
OPERATING TEMPERATURE RANGE
Max Altitude
ISOLATION TO UNUSED PORT
INPUT VSWR
INSERTION LOSS
Forward and reflect power monitoring system
1.11
Input, Output, U-Link, Inner Lines
Specification
470 to 860 MHz
≥ 5kW/≥10kW
3⅛”
-100C to +500C
3500 Meter.
≥ 60dB
≤ 1.05:1
≤ 0.1dB
To be included in
the offer
3⅛” unflanged U
links – (Cu Rigid
Lines only)
Functions:
1. Accept the output of any UHF TV channel between 470-860 MHz and
route the power to the antenna or the dummy load.
2. Provide transmitter interlocks for operational safety.
3. The schematic drawing shown in Annexure III must be referred for
details of U-Links, Power handling and the connections.
4. Provide forward and reflected power monitoring and it’s display for
each transmitter.
5. Provide compact package, which requires minimal maintenance and
immediate and simple installation.
7. The 7 port patch panel shall be mounted vertically on floor.
8. The U link provided should be able to remove and reconnect with
minimum effort and should have proper gripping, with locking and
unlocking facility.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 73 of 118 Annexure I-13
1.
SPECIFICATIONS OF 3⅛” / 4” RF FEEDER CABLE
Scope:- Doordarshan requires RF Coaxial air dielectric, Feeder cable of size (3⅛” /
4”) for High Power TV Transmitters at Rajauri (J&K) in UHF Band IV/V. The
particular R.F. Feeder cable shall be used to feed the R.F. Power output of the TV
Transmitters to the input of “TV Transmitting antenna system”. Actual cable length
will be intimated at the time of order however feeder cable length may be considered
as tentative as given in DD Specification. All RF cables shall be duly pressurized by
using Dehydrator (Dehydrator is not the part of the supply). The RF coaxial air
dielectric, Feeder cable should be complete in all respect.
2. Technical Specifications
2.1
Jacket
2.2
Cable Type
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
2.13
2.14
2.15
2.16
2.17
2.18
2.19
Size
Impedance, ohm
Maximum Operating Frequency
Relative Propagation Velocity
Peak Power Rating
RF Peak Voltage
Jacket Spark
Attenuation at 200 MHz
Attenuation at 500 MHz
Attenuation at 800 MHz
Outer conductor material
Inner Conductor Material
Operating pressure
Minimum Bending Radius, Single Bend
Cable Weight
Tensile Strength
Storage Temperature
2.20
Hoisting Stocking Spacing
2.21
2.22
Operation Temperature
Connectors
Standard Polyethylene black
Air-Dielectric, Corrugated
copper with high density
Polyethylene Helix
3⅛” / 4” dia
50 +/- 1 ohms
862 MHz
93% or better
800 KW or more
9700 Volts or more
8000 Volt RMS or more
0.56 dB/100m or less
0.94 dB/100m or less
1.24 dB/100m or less
Corrugated Copper
Corrugated Copper Tube
0.5 bar or more
1270 mm or less
3.8 kg/m or less
585 lb or more
-40°C to +65° C or better
Single value for spacing to be
specified by the OEM
(Origional Manufacturer)
-10° to +50° C or better
Each cable length must be
fitted with end connectors
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 74 of 118 2..23
2.24
2.25
2.26
2.27
2.28
2.29
2.30
(3⅛” EIA flanges) on one end
GAS STOP and other end
GAS THROUGH. No other
connector shall be acceptable.
To be quoted by the bidder
Recommended pulling length per
hoisting
Mean power rating at 400 C ambient
35 KW or more
Temperature
200 MHz
Mean power rating at 400 C ambient
21 KW or more
Temperature
500 MHz
Mean power rating at 400 C ambient
16 KW or more
Temperature
800 MHz
Wall gland with fitting arrangements to enter the cables from outside the
building to inside the building shall be supplied along with the cables
The 3⅛” flange end GAS STOP connector must be fitted with Schrader
valve to connect the cable with De-hydrator.
All RF cables shall be duly pressurized
The bidder shall quote for cable with end connectors and other
accessories as per suggestive BOM in Annex-IB
GENERAL INSTRUCTIONS TO COMPLETE OFFER: (R.F. Feeder Cable.)
3.1
The details of past supply for the similar RF Feeder Cables should be provided in
the following format:
Name and
Postal
Address of
the Firm
3.2
3.3
Name of Telephone
the contact and
Fax
person
Nos.
with
E
mail id
Make and
Model of
the
RF
Feeder
Cables
supplied
Power
Quantity
capacity of supplied
the similar
RF Feeder
Cables
supplied
The set of essential tool and other necessary equipment should be quoted
separately with the offer.
The RF Feeder Cables manufacturer /bidder must have his local office /
representative in India. The name, contacts, address of local office / representative
along with manufacturer’s authority letter in favour of local representative must be
given with the offer. The local office / representative in India will be nodal point
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 75 of 118 for resolving after sales issues. In case any item alongwith the RF Feeder Cable
system requires repairs at factory, the same would be handed over to local office /
representative in India, who would arrange repairs locally or export the defective
part to its O.E.M. and arrange its repair etc. The repaired item, will have to be
delivered by the local representative at transmitter site in India.
3.3
PRICE:-The Bill of material as given with commercial bid must be provided
with Technical bid without mentioning price.
3.4. The compliance of technical parameters of this specifications should be supported
by the figures in the published data sheets of the cable manufacturers.
3.5. INSPECTION AND ACCEPTANCE OF THE ITEM:
(a) All the items to be supplied against the supply order for this tender shall be
subjected to inspection at manufacturer’s facility by DD Engineer(s). The
expenditure for DD engineer(s) on To & fro airfare, per diem allowances, lodging,
boarding charges etc. shall be borne by Doordarshan. The bidder in his offer shall
cover inspection fee only, if any. The inspection fee if any shall not be included in
the main BOM for deciding lowest offer.
(b) In case pre dispatch inspection at the Manufacturer’s facility is not carried out
by DD engineer(s) due to any reasons, Copies of factory test reports of each
item/cable shall be provided. In addition, “VSWR” and “Distance to Fault”
measurement would be carried out by the manufacturer/supplier in presence of DD
inspector for each cable at the respective site, for acceptance of the item. If
required, the cable may be re-pressurized at the site.
(c) All technical equipment required for inspecting the system shall be provided
by the Manufacturer/supplier to the DD inspector.
(d) An acceptance test procedure for the R.F cable should be supply by the firm
one month in advance of the inspection of the cable so that same procedure could
be followed by D.D. Inspector for acceptance of the cable.
3.6
GUARANTEE:- The RF cable shall be guaranteed against any manufacturing
defects/faults for a period of twenty four months from the date of supply or
eighteen months from the date of installation. Any failure during the guarantee
period shall be repaired/replaced free of charge by the supplier at the site.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 76 of 118 Annexure I-14
C BAND/KU BAND SATELLITE RECEIVE EQUIPMENT
I. Specifications of Professional IRD for C-Band/Ku-Band:
a)
b)
c)
d)
e)
General:
The IRD should have a front panel display and one should be able to enter or edit
all the parameters for a perfect reception of the signals.
There should be provision for observing the BER (Pre & Post correction) of the
signal and signal level in the front panel.
IRD should be able to descramble BISS mode 1 and BISS-E signals.
IRD should have at least 10 memory setups to store channels.
IRD should have CI slot so that by inserting the CAM module signals can be
descrambled.
1. RF Parameters:
S. No.
Parameter
1.
Input Frequency Range
2.
No. of Inputs
3.
Tuning Step Size
4.
Satellite Frequency Band
5.
Input Impedance
6.
Input Connector
7.
Input Power Range
8.
Image Rejection
9.
Input Return Loss
10.
Noise Figure
11.
AFC Tuning Range
12.
De-Modulation Method
13.
Variable Symbol Rates
14.
Convolution Inner FEC
Rates selectable
15.
IF Filter Bandwidth
Specification
950 - 1750 MHz
1 No.
125 kHz, maximum
C- & Ku-Band, selectable
75 Ohms
F-Type female
-30 to -65 dBm per carrier
>30 dB
7 dB, minimum
20 dB, maximum
± 5 MHz
QPSK demodulation
1.5 to 40 M Symbol/sec
R= 1/2, 2/3, 3/4, 5/6, 7/8, (for QPSK)
Automatic Selection (dependent on Symbol
Rate)
2. Audio and Video Decompression Parameters
S. No.
Parameter
Specification
1.
Video Resolution (all
720 x 576, 704 x 576, 544 x 576, 480 x
resolutions shall be capable 576, 352 x 576 (other standard resolutions
of I, P & B frame decoding) should be selectable)
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 77 of 118 2.
3.
Video Decompression Type MP @ ML
Television Standard
PAL-B
Audio Decompression Type MPEG-layer-2 (Stereo/Musicam, i.e.
Single Mono, Dual Mono, Stereo, and Joint
Stereo)
3. Transport Stream O/P:
MPEG-2 ASI on BNC
4. Video Output Specifications:
i. Analog Video Output Specifications
S. No. Parameter
Specification
(a)
Connector Type
BNC (75 Ohms)
(b)
Quantity
1 No. of analog composite PAL-B
CCIR Standard (one main and one
for monitoring)
(c)
Level
1.0 V p-p +/- 5%
ii. Digital Video Output Specifications
S. No. Parameter
Specification
(a)
Connector Type
BNC (75 Ohms)
(b)
Quantity
1 No. of DIGITAL output compliant
to ITU-R BT.656 Standard
(c)
Level
800mV p-p for SDI
iii. Video Performance Specifications
S. No. Parameter
Specification
(a)
Frequency Response
Within 2 dB down at 5 MHz
(b)
Chroma-Luma Delay
±30 ns, maximum
(c)
Field Time Distortion
< 2%
(d)
Line Time Distortion
< 1%
(e)
Short Time distortion
< 2%
(f)
Differential Gain
< 4%
(g)
Differential Phase
< 2°
(h)
Signal to Noise Ratio
>55 dB (luminance weighted)
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 78 of 118 iv. VBI Signal Reinsertion Specifications:
S. No. Parameter
(a) VBI Formats Supported
(b) Range of VBI lines
(c) Synchronisation with
Video
(d) Preservation of line
numbering
Specification
WST
VITC
Field 1 lines 7 to 22 (PAL) and
corresponding lines of Fi2ld 2
Within ± 1 frame
VBI data shall be reinserted on the
original line number
5. Audio Output
5.1 Analog Audio:
a) Each analog audio output shall be presented as a stereo pair.
b) In the event of “Mono” transmissions, the same encoder input channel will be output
to both left and right connectors.
c) In other modes (“Stereo”, “Joint Stereo” and “Dual Mono”), the two encoder input
channels will be output as left and right.
d) Means shall be provided to combine the left and right channels on the IRD output
to produce a mono output from stereo transmissions to accommodate those sites not
equipped for stereo transmission.
5.1.1 Analog Audio Output Specifications
S. No. Parameter
Specification
(a)
Output Impedance
600Ω (balanced)
(b)
Number of Outputs
4, configurable as Stereo, Joint
Stereo, Single mono, Dual mono.
XLR Male Socket or with suitable XLR
(c)
Connector Type
Adapter (i.e., no terminal block)
5.2
Digital Audio Output Specifications
S. No. Parameter
Specification
(a)
Output level
5 Volts nominal
(b)
Output Format
AES/EBU
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 79 of 118 (c)
(d)
Load Impedance
Connector Type
(e)
Number of Outputs
110 Ohms
XLR Male Socket or with suitable XLR
Adapter (i.e., no terminal block)
2, Stereo Channels
5.3 Audio Performance Specifications at 256 Kbps and sampling rate of 48 KHz
6.
S. No. Parameter
(a)
Peak Output Level
(b)
Clipping Level
Specification
+ 18 dBm into 600Ω balanced
S/W Selectable to be provided or
any preset value between +18dbu
to +25 dBu.
(c)
(d)
(e)
(f)
(g)
(h)
Sampling Rate
Frequency Response
THD
Dynamic range
Crosstalk at 1 kHz
48 KHz
40 Hz to 20 kHz ± 2 dB
<0.3 % at 1 kHz
80 dB (ITU-R/Arm weighting)
60 dB, full scale (20 Hz to 20 kHz)
Signal to Noise Ratio
55 dB(min) at 0dBm
LNB Power Supply & Control
S. No. Parameter
(a)
LNB Voltage
(b)
(c)
(d)
7.
II.
Size
Mount:
Power Consumption
Over Current protection
LNB Power Supply &
Control
Specification
+ 13 V (Vertical)/ 18 V (Horz)
polarizations switching or 19 V fixed.
400 mA. (Max.)
Fold back current limiting.
Receive Polarization Control by
electrical Command Via LNB-IF
feeder (High & Low band
switching Pulse for Ku Band
operation).
19” rack mountable.
Specification for the motorized Feed of Ku Band/C- Band
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 80 of 118 1. Focus
2. Frequency
3. Ports
4. Polarization discrimination
5. Polarization Adjustment
III.
: Prime/offset focus,
: Ku- band / C- band
: 2 ports, for receiving both linear and
Orthogonal polarization signals
: 30 dB ( min )
: -5degree to 95 degree
Specifications for Cables & Connectors
An interconnecting low loss cable of length of 75 meters is required with the 6.2 M
PDA. The cable should be quoted in denomination of 50m & 25m, which can be used
independently (i.e. as 50m or 25m) or collectively i.e. as a 75m length using a coupler (IConnector) in between the 50m & 25m cables between outdoor and indoor units. The
total insertion Loss for cable should not exceed 15dB at 1450 MHz. Two sets of cables
are to be quoted.
IV.
Specifications for Parabolic Dish Antenna, solid type, 2.4 M (dia)
S. No.
(a)
(b)
(c)
Parameter
Antenna type
Frequency
Size
Specification
Offset / Prime Focus
10.7 GHz to 12.75 GHz
2.4 m diameter
(d)
(e)
(f)
(g)
(h)
3dB beam width
Aperture efficiency
Gain at 11.7 GHz
Drive system steerability
Azimuth
(i)
(j)
Elevation
Feed
(k)
(l)
Polarization
Mount option
Better than 1º
Better than 70%
Better than 47 dB (min)
Manual
0 to 3600 continuous with fine
adjustments
10 deg to 85 deg
Prime focus, 2 port, for receiving
both linear orthogonal polarized
signal.
Linear orthogonal
Pole Az-El and Pole wall to be
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 81 of 118 (m)
(n)
(o)
(p)
V.
Reflector Material
Feed Impedance
Feed VSWR
Wind loading
quoted separately.
Mount should be powder coated/
hot dip galvanized.
Glass fiber reinforced polyester
50 ohms
better than 1.5 : 1
80 Km/h operational, 200 Km/h
survival
Specifications for Parabolic Dish Antenna, 6.2 M (dia) with De- Icing
kit.
S. No.
a)
b)
Parameter
Antenna type
Feed
Specification
Parabolic reflector solid type
Prime focus, 2 port, for receiving
both linear orthogonal polarized signal.
3.7 GHz to 4.2 GHz
6.2 m diameter
c)
d)
Frequency
Size
e)
f)
g)
h)
i)
j)
Gain at 4 GHz
Polarization
G/T with 300 K LNB
Mount
Drive System
Steerability
(i)
Azimuth
(ii)
Elevation
(iii) Polarization
Better than 45.5 dB (min)
Linear orthogonal
27.2 dB/k at 4 GHz (min)
Azimuth – elevation
Manual
k)
l)
m)
n)
Feed Impedance
Feed VSWR
Cross-pole discrimination
Aperture efficiency
50 ohms
better than 1.3 : 1
30dB (min)
Better than 70 %
o)
Wind loading
70 Km/h operational, 200 Km/h
survival
± 90 Deg (1200 continuous)
5 deg to 85 deg
± 90 Deg (Min)
2. Notes:
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 82 of 118 2.1 The structural analysis may be provided from structural engineer to asses
the strength.
2.2 A calibrated graduation of Azimuth, Elevation and Polarization offset
should be provided in the antenna.
VI. Specifications for the Digital LNBC in C band
1. Technical Specifications:
S. No.
Parameter
Specification
a)
Input frequency range
3.4 GHz to 4.2 GHz
b)
Local Oscillator frequency
5.150 GHz
c)
L.O. Stability
± 25 KHz or better
L.O. Phase noise
Better than 90 dBc/Hz @ 100kHz (min)
d)
Output frequency
950 MHz to 1750 MHz
e)
Conversion gain
60 dB (min.)
f)
Gain response
Better than ± 0.5 dB/40 MHz
g)
Output level at 1dB
3 dBm
compression point
h)
Output Connector
F type female
i)
Input VSWR/Output VSWR Better than 2:1
j)
Noise Temperature
Better than 30deg K
k)
Power supply requirement
Should work between + 15V to +24V
l)
m)
Input flange
Lightening/Surge protection
CPR 229
Should be provided
2. LNBC should be environmentally sealed against weather conditions and extremes of
temperature (-10ºC to 50 ºC). LNBC should also be 100% water proof.
VII.
SPECIFICATION for the Digital LNBC in Ku band
1. Technical Specifications:
S. No.
Parameter
Specification
a)
Input frequency range
10.95 GHz to 11.7 GHz
11.7 GHz to 12.2 GHz
b)
Local Oscillator frequency LO freq of LNBC should be capable to
provide output frequency of LNBC
between 950 to 2150MHz.
c)
L.O. Stability
± 100 KHz or better
L.O. Phase noise
Better than 75 dBc/Hz @ 1kHz
d)
Output frequency
950 MHz to 1450 MHz
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 83 of 118 e)
f)
g)
h)
i)
j)
k)
l)
m)
2.
Conversion gain
Gain response
Output level at 1dB
compression point
Output Connector
Input VSWR/Output
VSWR
Noise Figure
Power supply requirement
Input flange
Lightening / Surge
protection
60 dB Typical
Better than ± 0.5 dB/27 MHz
3 dBm
F type female
Better than 2:1
Better than 1dB
Should work between + 15V to +24V
with current consumption of about 200
MA
WR 75
Should be provided
LNBC should be environmentally sealed against weather conditions and
extremes of temperature (-10ºC to 50 ºC). LNBC should also be 100% water
proof.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 84 of 118 Annexure I-15
SPECIFICATIONS FOR 80KVA (1+1) STAND ALONE, SELF CONTAINED,
WATER COOLED SILENT TYPE DIESEL GENERATOR SET
GENERAL:
The Stand Alone, Self Contained in a weather proof enclosure canopy, Silent
type water cooled Diesel Generator set of 80 KVA capacity (at site condition), 415 V, 3
phase, 50 Hz, 4 wire is required for TV transmitters at Rajauri (J&K).
SUMMARY :
1. Section - I: General (General conditions governing the supply.)
2. Section - II:
Technical Specifications .
SECTION-I:
1. GENERAL
1.1
1.2
Scope:
This section covers the general conditions governing the design, supply, factory
testing, transportation to site, Installation, Testing, and Commissioning satisfactory
operation of DG Set at the site .
Location :
The Stand alone, Self Contained in weather proof canopy Silent type Water cooled
DG set will be installed on cement concrete platform for outdoor application.
1.3
General Conditions :
1.3.1 The DG SET should generally conform to the technical specifications in Section II. Should a bidder, however, desire to depart in any respect from the given
specifications either on account of manufacturing practice or for any other reasons,
he must specifically point out the modifications explaining in detail each and
every departure he proposes to make.
1.3.2 The DG Set should be designed for efficient and trouble free service for 24x7 hrs.
of continuous operation at a stretch. All materials used in the manufacture should
be conform to the IS: 10002-1981 and 13364(Part-2)-1992 amended to date.
1.3.3 All work should be carried out in accordance with standard mechanical &
electrical practice. The units should be designed for ease in operation,
maintenance and complete safety to operating personnel.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 85 of 118 1.3.4 Only easily available standard components should be used as far as possible. The
bidder should submit an undertaking to make available spares and replacement
parts for a period of ten years.
1.4
Completeness of contract:
All fittings and accessories which may not have been specifically mentioned or
which the bidder may not explicitly mention in his tender but are necessary for the
satisfactory operation of the DG Set should be deemed to be included in the contract
and is to be provided by the contractor without any extra charge.
1.5
Documents to be submitted (with tender)
The bidder should submit following documents along with technical bid without
which tender will be considered incomplete & is liable to be rejected.
1.5.1 Printed original leaflets with illustrations of DG set Components viz. Engine,
Alternator, ventilation systems, Control Panel and Acoustic canopy.
1.5.2 Experience certificate in manufacturing/ assembling of 80 KVA silent type, Water
Cooled D/G Set for above capacity in their own name during the last five years. A
list of such works giving details of capacity & date of supply along with the
completion certificates issued by the client department.
1.5.3 Certificate of Original Equipment Manufacturer (OEM) / Original Equipment
Assembler (OEA) of the offered make/model of Engine and Alternator.
1.5.4 A valid copy of ISO 9001: 2000 Certificate of OEM/OEA of the offered D/G set
(Engine and Alterrnator).
1.5.5 Test certificate of similar type and capacity Engine and Alternator.
1.5.6 List of standard tools as part of DG set required for the maintenance of the DG
set.
1.6
Documents to be submitted After Acceptance of Tender:
1.6.1 Six copies of the drawings in plan, elevation & section showing the dimensional
details, location, accessories etc. of the DG Set should be sent to Indenter within
two weeks of acceptance of the tender for approval before taking up
manufacturing. Two sets will be returned after approval.
1.6.2 Two copies of installation, assembly at site, operation, maintenance and trouble
shooting manual having details of routine, preventive/ corrective and periodical
maintenance.
1.6.3 Following documents/details will have to be supplied to the consignee along with
the D/G Set at the time of delivery:
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 86 of 118 a)
Two copies of the book of instructions for the Installation,
Testing, Commissioning, Operation and Maintenance of DG Set.
b) Factory Test Certificates showing the results of tests actually conducted on the
Engine, Alternator & Accessories.
c) Two sets of finalized drawings showing dimensions and other fixtures on the
DG Set. including wiring of panel.
1.6.4 Two set of drawing and Manuals/instruction book-let etc of DG Set should
be sent directly to Director Engineering (Transmitter Design), DG:DD, Doordarshan
Bhavan, Copernicus Marg, New Delhi-110001, as soon as drawings are approved by
the Indenter.
1.8
PACKING
The packing should be suitable to withstand transportation hazards. Each packing
should contain a packing slip giving the details of the contents and bear the
address of consignee. A copy of packing slip giving the list of items included in
the package together with the package number should be mailed in advance to
the consignee.
GUARANTEE:
1.9
The DG Set should be guaranteed in all respects for satisfactory operation under
full load condition for one year from the date of taking it into service.
1.10 INSTALLATION:
The supplier is required to SITC (Supply, Installation, Testing & Commissioning)
tender/works. All internal wiring jobs including the supply of Main Cable from
Alternator to Control Panel should be done by bidder.
1.11
SPARES:
Along with the diesel generator, the Bidder should also quote separately for
recommended spares for two years operation of DG set giving list of all the spares
alongwith price of each item of spare by considering that DG set will be running
continuously for at least 12 hrs. per day . The list of recommended spares should
be based upon field reports and should be sufficient enough for trouble free
operation of the DG Set at remote locality.
1.12 MISC. CONDITIONS:
1.12.1The supplier should make good/repair the damage to indentor building during
installation, testing etc. of the DG set.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 87 of 118 1.12.2The supplier should hold indentor or it’s representative harmless for any liability/
compensation by his employee or third party for any damage/ loss of life or
property to them during the execution of project.
1.12.3Supplier/ his installation crew will make their own arrangement for stay during
installation of DG set.
1.12.4Supplier will comprehensively insure entire martial for loss/theft till installation is
completed and handed over to the consignee. Policy in this regard should be
submitted along with initial consignment.
1.14. TESTING/ACCEPTANCE AT SITE:
The supplier should show all the required tests at site as per mutually agreed
acceptance procedure according to relevant standard of BIS for such jobs at no
load, partial load and full load (in steps of 20% from no load to full load). The
consumable items like fuel, lubricants, belts etc. during this testing should be
arranged by the bidder.
1.15. C E A CLEARANCE:
The supplier should have to arrange CEA clearance for DG set before the same is
offered for acceptance to indentor at site.
SECTION_-_II
2.
TECHNICAL SPECIFICATIONS
The stand alone, silent type, Water Cooled, D/G set mounted on a self contained rust
proof chassis complete with weather proof, sound proof Acoustic enclosure with built
in exhaust & ventilation system. D/G Set should meet the noise level. All units &
accessories should be housed on single chassis inside the enclosure.
2.1 ALTERNATOR :The Alternator will conform to IS : 13364 (Part - 2) – 1992 for
manufacturing , Enclosure of alternator as per IS : 4691 IP 23,
mounting as per IS : 2253 & testing of Alternator as per relevant IS
with latest amendments. The Alternator must be of ISO certified
manufacturer like KEC / STAMFORD/ AVKC.
S. No.
Item
DD’s Requirement
Bidders Offer
2.1.1 Electrical Output
80 KVA at site conditions
(Prime Power)
2.1.2 Make
To be indicated by bidder.
2.1.3 No.of
phases
& 3 phase with Neutral point in
interconnection
between terminal box, Star Connected
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 88 of 118 2.1.4
2.1.5
2.1.6.
2.1.7.
2.1.8
2.1.9
2.1.10
2.1.11
2.1.12
2.1.13
2.1.15
2.1.16
2.1.17
phases if any
Rated Voltage
Voltage regulation
415 V (Nominal)
+ 1.0 % from no load to full load
at lagging power factor of 0.8 to
1.0 and speed drop of less than or
equal to 4%
Power Factor
Better than 0.85 (lagging)
Frequency in Hz
50 Hz + 4 %
Speed in RPM at rated load 1500 RPM
Type of coupling
Alternator to be coupled either
directly to engine or through
flexible rubber coupling on a
common fabricated base frame
Exciter
(I) The alternator should be self
regulated, self excited and rated
for continuous operation from no
load to full load under all working
conditions.
(II) The alternator should be able
to supply unbalanced load as
specified in IS : 13364 (Part-2) :
1992 with latest amendments.
Exciter rating
It should be rated for 1.25 times
the full load conditions
Earthing
As per IS:3043 – 1987 amended to
date
Type of load to be connected i. Broadcasting Transmitter
load instantaneously and
continuously varying above a
specified limit.
ii. Building light, Flood lights
and Power Loads.
Type of Duty
Continuous
Type of Field
Rotating
Class of Insulation
Class 'H'
2.1.18 Construction
2.1.19 Cooling
Horizontal, foot mounted with ball
or roller bearing and end shields
Machine should have cooling
provision as per IS : 6362 - 1971
IC 01 amended to date
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 89 of 118 2.1.20 Temperature rise
2.1.21 Overload capacity
2.1.22 Over speed
2.1.23 Protection
circuit
against
2.1.24 Vibration
2.1.25 Noise
(I) Output Terminals
2.1.26
Limited to Class H as per IS
12802 and IS 4722:1992 amended
to date
1.5 x rated FLC for 30 secs. or 1
hr within 6 hrs with 10% over
load
To withstand the speed of 1.2
times of the rated speed.
short Short circuit protection to be
provided. (Pl. indicate the
device/system used.)
As per IS - 12075:1987 amended
to date
As per IS 12065: 1987 amended to
date
Terminal box should be mounted
on top of stator body suitable for
connecting 120 Sq. mm 31/2 core
PVC Aluminum conductor cable
(II) Terminal Marking
2.1.27 De-rating Parameters &
output at site condition
2.1.28 Rated FLC
2.1.29 Efficiency at 0.85 p.f. (lag)
As per IS 4728: 1975 amended to
date
To be given by the Bidder.
To be given by the Bidder.
More than or equal to 92 % for
25 % to 100 % Load. Design of
Alternator should be such as to
have maximum efficiency at 75 %
of Prime Power rating at NTP.
2.1.30 Waveform Distortion (THD) As per IS
2.1.31 Unbalanced load permitted Not exceeding 20% rated FLC in
any phase
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 90 of 118 2.2 DIESEL ENGINE
S. No.
Item
2.2.1 Type of engine
2.2.2 Make
DD's Requirement
Self-start, 4 stroke, Turbo-charged
To be indicated by tenderder
2.2.3
Capacity
2.2.4
2.2.5
Type of fuel
Method of Cooling
2.2.6
Method of starting
i. To be rated for continuously driving the
alternator to deliver the rated full load
output at site condition .
ii.
The Bidder should specify the
capacity of the Diesel Engine offered by
him alongwith the computations of
various de-rating applied as per relevant
IS.
H.S. Diesel Oil
i. Water-cooled with Radiator.
ii.
Provision for anti-rusting, anticorrosion & anti freeze arrangement for
water coolant is to be provided, if
applicable.
iii. Jacket Water system should be free
from rubber hoses for reducing the risk of
leakage and therefore engine failure.
iv. Cooling System should be provided
with Twin Thermostats, permanent
lubricated water pump.
i. The Engine should be cold starting type.
ii. It should be battery started
iii) Starting switch with key should be
provided on engine control panel. Starting
motor with battery charging alternator
alongwith voltage regulator and activation
switch should be integral part of the
starting system.
iv) One Ammeter should also be provided
in the battery Charging circuit.
v) Battery offered should be maintenance
free tubular electrode type of standard
DGDD/TxD/5kWHPT Specs/J&K/2010 Bidder Offer
Page 91 of 118 2.2.7
2.2.8
2.2.9
2.2.10
2.2.11
2.2.12
2.2.12
2.2.13
2.2.14
2.2.15
2.2.16
Capacity of fuel tank
make
like
EXIDE/STANDARD
FURUKAWA etc. and complete with
charging connecting leads, & terminals.
The Ampere hour rating and no. of plates
of battery should be indicated.
Service Tank of capacity with suitable
dial type fuel gauge (NB: Tank should be
part of self-contained cabinet & housed
suitably.)
Speed of Engine
1500 RPM with class A1 governing as
laid down in IS-10000.
Type of Exhaust A heavy-duty residential type exhaust
system
silencer to be provided.
i) The Engine should be protected
Engine protection
against High water temp. with audio &
visual alarm.
ii) Over speed protection through hour
meter cum RPM indicator with Audio
and visual alarm.
iii) Low Lubricating Oil Pressure
Protection with audio and visual Alarms.
Accessories
for Standard Accessories
Engine
Vibration Insulation Anti-Vibration Pad of Polybond/
Resinoflex make should be provided.
Base frame
Common MS channel fabricated, rigid,
rust proof & with suitable anti-vibration
mounting.
Consumption of fuel
and lubricant(Ltrs/ At Site Conditions:
(a) …………. lts/hr at 25 % load.
hrs)
The Bidder will (b) …………. lts/hr at 50 % load.
submit this data at (c) …………. lts/hr at 75 % load.
(d) …………..lts/hr at 100 % load.
site condition.
Lub. oil specification As per IS
Total lubrication
To be given by the Bidder
system capacity
Total coolant
To be given by the Bidder
capacity
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 92 of 118 2.2.17 Fuel system
Direct fuel injection system with fuel lift
pump inline type.
2.2.18 Exhaust Gas Volume To be given by the Bidder at 75 % and
100 % prime Power rating
2.2.19 Exhaust Gas Temp.
To be given by the Bidder at 75 % and
100 % prime Power rating
2.2.20 Smoke Level
Harmful Gaseous emission should meet
the Pollution Board norms for
Environment protection.
2.2.21 Regulation
As per IS
2.3
S. No.
COMPLETE DIESEL GENERATOR SET :
Item
DD's Requirement
2.3.1. Type of DG set
2.3.2.
2.3.3.
2.3.4.
2.3.5.
2.3.6.
2.3.7
Silent ,Self contained, Standalone with acoustic
enclosure.
Dimensions of
(a) Length : To be given by the Bidder
D/G Set including (b) Width : To be given by the Bidder
Acoustics
(c) Height : To be given by the Bidder.
Enclosure
Total Weight of To be given by the Bidder.
D/G Set
Type of Enclosure DG set should be housed in a Acoustic
Enclosure consisting of Acoustic Insulation,
Non-inflammable, Canopy Ventilation System
with CFM details , doors and suitable for
outdoor use.
Noise level
Complete D/G set including Engine should
meet the Pollution Board norms as per IS
Smoke Level
Harmful Gaseous emission level should meet
the Pollution Board norms for Environment
protection at the time of delivery of DG set.(
Original certificates to be enclosed from
authorized agency)
Exhaust pipe
Exhaust pipe as per IS latest instruction of
Pollution board.
DGDD/TxD/5kWHPT Specs/J&K/2010 Bidder
Offer
Page 93 of 118 2.3.8.
2.4
EARTHING
As per IS
ENGINE AND ALTERNATOR CONTROL PANEL
S.No.
DD’s REQUIREMENT
2.4.1
Control panel for 415 V 3-phase, 50 Hz , 4wire AC supply should
have following features & accessories.
It should be mounted on the enclosure with hinged panel and will
be wired up as per standard practice & as per I.E. rules.
It should be fabricated out of CRCA SHEET duly processed in 7
tank, dust proof, vermin proof & power coated.
i.
ii.
iii.
The Alternator panel is to be provided with 200 Amp (Draw out
type) 4 Pole ACB & adequate space for connecting outgoing &
incoming as per IS . The rating of ACB/ contactors/ relays will be
suitable for 80 KVA and rating of interconnecting copper cables
should be suitable for taking at least 1.5 time the rated current.
2.4.2. The Panel should comprise of following Instruments :
(a) Start/Stop switch with key
(b) Local/Remote control switch
(c) Frequency meter
(d) DC Voltmeter & Ammeter for battery charging
(e) AC Voltmeter (Flush type) with Selector switch
(f) kW meter, pf meter,
(g) Ammeter (Flush type) having scale more than 20% full load
current with selector switch
(h) Instrument fuses/ MCBs
(i)Low oil pressure & high water temp. Audio alarm.
(j) Priming pump starter(k) Hour meter
(l) RPM meter (Tachometer)
(m) KWH meter
DGDD/TxD/5kWHPT Specs/J&K/2010 Bidder’s
Offer
Page 94 of 118 2.4.3.
2.4.4.
The Panel should comprise of following Indications :
(a) Set ON
(b) Load ON
(c )Remote control
(d) Low Lubricating oil
pressure
(e) Over speed
(f) High Enclosure temp.
(g) High water Temp.
PROTECTION : FOR GENERATOR :
(A) ALTERNATOR:
i) Earth fault protection through relay.
ii) Under voltage protection through relay.
iii) Under frequency protection through relay.
iv) Over current (through MCCB/ACB release)
v) One set of fuses should be provided for instruments &
control
circuit.
(B) ENGINE:
i) Protection against following
a. Engine Over speed b. Low Lube Oil pressure
c. High water Temp.
ii) One set of audio and visual Alarm for above protection.
2.4.5. The Engine Local Control Panel should have following
features
a) Start/stop push button with key for local starting.
b) Special switch (or any other method) on the local control
panel providing locking in any of the three positionsi. Remote ii. Local iii. Off-No rotation at all.
c) A timer to ensure that the starter is not pressed for a long time.
d) A pressure switch to ensure that the starting motor is not
energized,
when the generator is running.
e) Lubricant Oil Temp. gauge
f) Hour cum Tachometer
2.4.6. Power supply for Space Heaters of Engine :
Suitable arrangement through push buttons should be
made for power supply to Space heaters from the battery of DG
set. The Ampere Hour rating of the battery may be offered
accordingly.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 95 of 118 Annexure I-16
SPECIFICATIONS OF 60 KVA 3 PHASE INPUT 3 PHASE OUTPUT UPS
SYSTEM ALONGWITH ISOLATION TRANSFORMER FOR TV
TRANSMITTERS
1.0 GENERAL:
1.1 Doordarshan requires Uninterrupted Power Supply System (UPS System IN
1+1 MODE) for backup Power Supply for its High Power TV Transmitters.
The UPS should be reliable and stable in operation under Indian tropical
conditions. This Specification describes a 60 KVA three-phase, True on-line
double conversion continuous operation (defined as VFI in the IEC62040-3
UPS Specifications), solid-state Uninterruptible Power Supply. The UPS
system shall be capable of running in single stand-alone Module with 15
minutes back up time at full rated capacity. All connectors & cables etc.
required for UPS System & its installation should be supplied with the
equipment. The UPS System quoted must conform to the latest international
standards of safety and EMC. The conformance to such standards (indicating
standard’s name & number) must be stated in compliance statement. The UPS
and battery manufacturer must be ISO 9001-2008 certified for manufacturing
of UPS and battery (respectively). A copy of the valid ISO 9001-2008
certificate should be enclosed with the offer.
1.2 The capacity “60KVA” may be treated as suggestive. However, it is the
responsibility of the bidder to calculate the exact capacity of the UPS and
consequently the requirement of battery bank for 15 minutes back up, taking
into consideration the load of transmitter, cooling system, input monitoring,
measuring equipment and any other auxiliary equipment as part of the system
with necessary margin for calculating the capacity of the UPS.
1.3 All the other technical specifications paras and sub paras are to be complied.
2. TECHNICAL SPECIFICATIONS OF UPS SYSTEM:
2.1
The UPS shall produce high quality sinusoidal output.
The UPS shall be designed to operate as true on-line, double conversion type
UPS strictly as per the definition of IEC 62040-3 as follows:
2.1.1 Normal Operation:
The critical AC load should be continuously supplied by the UPS inverter. The
rectifier & charger should take power from the AC input source, covert it into suitable
DC and supply to the inverter as well as charge the Batteries on Automatic Float cum
Boost Mode.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 96 of 118 2.1.2 Upon Mains Failure:
Upon failure of AC input power, the critical AC load should continue to be
supplied by the inverter, which should obtain power from the battery. There shall be no
interruption in power to the critical load upon failure or restoration of the AC input
source.
2.1.3 Upon Mains Restoration:
Upon restoration of AC input power, the Rectifier/Charger should automatically
restart walk-in and gradually take-over the supply to inverter and charging to the battery.
2.1.4 Static Bypass:
Each UPS Module should have in-built 100% rated static Bypass Line.
2.3
Static Transfer Switch:
Static Transfer Switch and bypass circuit shall be provided as an integral part of
the UPS. The static switch shall be naturally commutated high-speed static (SCR Type)
device rated to conduct upto 135% of full load current, continuously.
The Overload withstanding capability of Static Bypass Path should be 1000% for
100 millisecond, 135% - 170% for 10 minutes.
2.4
Maintenance Bypass Isolator:
2.4.1 General:
A manually operated maintenance bypass isolator shall be incorporated into the
each UPS cabinet to directly connect the critical load to the input AC power source,
bypassing the rectifier/charger, inverter, and static transfer switch.
2.4.2 Maintenance Capability:
With the critical load powered from the maintenance bypass circuit, it shall be
possible to check out the operation of the rectifier/charger, inverter, battery, and static
transfer switch.
2.5
Technical Specifications:
2.5.1 System continuous rating 60 KVA, 48 KW at 0.8 power factor.
2.5.2 Battery Capacity: The UPS system must be capable of providing supply to the
UPS Inverter/s on 60 KVA/48 KW load for minimum 15 minutes of battery back-up
time. The Battery Bank shall be MF-VRLA type (Make GNB/ Amara Raja/ HBL Nife)
consisting of 2 V cells installed in proper standard cabinets with proper connections and
in factory charged condition. The battery calculation is as follows:
BATTERY SIZING CALCULATION GUIDELINE (FOR VRLA BATTERIES)
Type of Battery
: Maintenance Free Valve Regulated Lead Acid With 20
Year Design Life (Amara Raja/HBL Nife/GNB Make).
Nominal DC Bus Voltage
: X V DC
Nominal Cell Voltage
: 2 V per cell
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 97 of 118 Thus, No. of Cells (N)
End Cell Voltage (V)
: N(X/2)
: 1.75 Volts
Load Duty Cycle (L)
: 48 KW Continuous
Inverter Efficiency
: E (93%)
Back up Time
: 15 Minutes
Maximum Current for the above Load (I dc) = L x 1000/(VxNxE) Amps. DC
The Other Factors to be Considered :
1) Temperature Correction Factor (T)
2) Capacity Factor (K)
Chart
1.0731 (40OC)
K (Factor being taken care of from
Supplied by battery manufacturer
for
calculating backup time)
Considering the above Factors the required Battery Capacity = I dc x K x T
= ……………. AH
Therefore, for supplying to 60 KVA UPS System at full load for 15 Minutes at
least 60130 VAH (1 Set) will be required.
2.5.3 Rectifier Input: 415 Volts, three-phase, 4-wire-plus-ground
Bypass input: 415 Volts, three-phase, 4-wire-plus-ground.
Output: 415 Volts, three phase, 4-wire-plus-ground.
2.5.4 Input Voltage range: 320 V to 460 V (415 V nominal) for 100% load
2.5.5 Input Frequency: 50 Hz
2.5.6 Frequency Tolerance: 45 Hz-55 Hz
2.5.7 Power Walk in: 5 – 30 seconds (User programmable)
2.5.8. Input Power Factor
> .98 for all loads
In order to achieve this, the Rectifier must be IGBT based; Power Factor
Corrected and DSP Controlled.
2.5.9 Input Current Harmonic Distortion: < 4% THD maximum at 100% load and <
3% THD at 75% load at nominal input voltage.
2.5.10 Output Voltage regulation:
1.
+/- 1% steady state for a static 100% balanced load.
2.
+/- 2% steady state for a static 100% unbalanced load.
3.
+/- 5% for a 0 to 100% load step.
2.5.11 Output Frequency: 50 Hz +/- 0.1 Hz free running (battery/mains operation).
2.5.12 Output Power Factor Range: 0.9 leading to 0.8 lagging at rated KVA.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 98 of 118 2.5.13 Output Harmonic Distortion:
1.
<2% THD maximum for a 100% linear load.
2.
<5% THD maximum for a 100% non-linear load.
2.5.14 Crest Factor: 3: 1 or better
2.5.15 Voltage Transient Response:
1.
+/- 3% for a 50% load step.
2.
+/- 5% for a 100% load step.
2.5.16 Voltage Transient Recovery Time: 20 milli-seconds.
2.5.17 Phase Displacement:
1.
120 degrees +/- 1 degree for balanced load.
2.
120 degrees +/- 1 degree for 50% unbalanced load.
3.
120 degrees +/- 2 degree for 100% unbalanced load.
The system should be capable of supplying energy to load from commercial mains
without any break, in case of phase reversal at the input. It should also generate aural and
visual alarm in such a case.
2.5.18 Overload Capability:
1.
2.
3.
4.
110 % for 60 Mins.
125 % for 10 Mins.
150 % for 1 Mins.
1000% for 100 milliseconds & 135-170% for 10 Mins in bypass operation.
2.5.19 Short Circuit Withstand: The UPS must withstand a bolted fault short circuit on
the output without damage to the UPS module.
2.5.20 Inverter efficiency: >93% at 100% Non linear load, at nominal voltage with
batteries fully charged.
2.5.21 Acoustical Noise: < 67 dB (A) of noise, typical, measured at 1 meter from the
equipment surface.
2.5.22 Transient Voltage Surge Suppressor (TVSS) should be provided at the input &
output of the UPS System.
2.5.23 Please specify UPS Cubical and Battery Rack dimensions LXBXH in meters.
Floor layout plan with dimensions may be given.
2.6
Environmental Condition:
The UPS shall be able to withstand the following environmental conditions
without damage or degradation of operating characteristics:
2.6.1 Operating Ambient Temperature
UPS Module: 00C to 450C
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 99 of 118 Battery:
00C to 450C
2.6.2 Storage/Transport Ambient Temperature
-250C to +550C
2.6.3 Relative Humidity: <90% at 200C
2.6.4 Altitude Operating: The UPS should be able to deliver the rated output up to
3500 meters above Mean Sea Level.
2.6.5 Input Current Walk-In:
The rectifier/charger shall contain a timed walk-in circuit that causes the unit to
gradually assume the load over a 5 to 30 second (User Programmable) time interval after
input voltage is applied.
2.6.6 DC Filter:
The rectifier/charger shall have an output filter to minimize ripple voltage into the
battery. The Ripple voltage should be less than 0.5%. The Ripple Current should be
≤5% of battery AH capacity.
2.6.7 Battery Recharge:
(a) In addition to supplying power for the inverter load, the rectifier/charger shall be
capable of providing battery charging current to recharge the battery properly (up to 10%
of battery AH capacity). Total Battery Management and monitoring should be available
in the System. In addition to the above manual charging current control may also be
provided.
(b) The Battery Charger system should be able to sense source of supply as mains or
Diesel Generator. In case the source of supply is Diesel Generator, it should disable
battery charging and the rectifier circuit should only supply the load current. This is
required to avoid overloading of the Diesel Generator as the existing 62.5 kVA Diesel
Generator is sized optimally to take care of the present load of transmitter and allied
equipment only and not the additional load of the ‘UPS - battery charging’. For this
purpose a potential free NO/NC contact from AMF panel of DG set shall be provided by
Doordarshan and this may be utilized by the UPS supplier to disable battery charging on
the Diesel Generator set. The normal functioning of Battery charging should be restored
immediately on switching of prime source of supply as AC mains. A line diagram of the
above arrangement must be submitted with the offer.
2.6.8 Output Frequency
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 100 of 118 The output frequency of the inverter shall be controlled by an oscillator. The
Oscillator shall hold the inverter output frequency to +/- 0.1 Hz for steady and transient
conditions.
2.6.9 Low Battery Voltage Protection: To prevent total discharge or damage to the
battery, the UPS must transfer to standby operation when the battery voltage reaches a
minimum voltage level (programmable).
2.6.10 Battery disconnect: An external MCCB is to be provided for protection and
isolation of the battery bank from the rest of the system.
2.6.11 RF Shielding: The UPS must have RF (Radio Frequency) radiation shielding
since it will be installed in strong RF field environment of 10 KW power. Any failure of
electronics due to RF pick-up must be taken care of by the manufacturer.
3.0
DISPLAY AND CONTROLS:
3.1.
Monitoring and Controls:
The UPS shall be provided with a status display and control section designed for
convenient and reliable user operation. A system power flow diagram, a percentage load
and battery time remaining display shall be provided as part of the monitoring and
controls sections which depict a single line diagram of the UPS. The monitoring
functions such as metering, and alarms shall be displayed on a multilingual Graphic
florescent backlit LCD. Language features of the monitoring system shall be in English.
Minimum 100 PIECES HISTORIC EVENT RECORD should be there.
3.2
Metering
The following parameters shall be displayed:
a)
Input Voltage & Currents, Frequency, Power Factor
b)
Bypass: Phase Voltage, Line-Line Voltages, Frequency
c)
UPS Output:
Phase Voltages, Currents, Line-Line Voltages, Power
Factor,
Frequency
d)
Local Load:
Load of Each Phase Active Power (KW), Apparent Power (KVA) of each
Phase, Load Crest Factor
e)
Battery: Battery Bus voltage, Battery Charge & Discharge current,
Forecasted
Battery Back-up Time, Battery Temperature Battery Capacity (AH)
f)
Parallel Load (for Parallel Operation System): Apparent Power
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 101 of 118 (KVA) of Each Phase, Active Power (KW) of Each Phase
3.3.
Warning, Protection and Alarm Messages:
a)
Input/Mains:
Charger Fault, Input Fuse Fail, Control Power 1 Fail, Mains Phase Reversed,
Mains Voltage Abnormal, Mains Under-Voltage, Main Frequency Abnormal
generator connected, Input Disconnect Open/closed
b)
Rectifier/Input Inductor/DC Bus/Booster/Balancer:
Input Inductor over Temperature, rectifier Fault, rectifier over-current, Soft Start
Full, Rectifier Comm. Fail, Rectifier in setting, Rectifier Over Temperature, DC
Bus Abnormal, DC Bus Over-Voltage, Balancer Fault, Balancer Over-Current,
Balancer Over-Temperature
c)
Battery:
Battery Over-Temperature, Battery Fault, Battery replaced, Battery Low
pre-warning, Battery end of Discharge, Battery contactor Fail, Converter OverCurrent, Battery Capacity Testing, Battery Maintenance Testing, Battery Fuse
Fail, Battery Contactor Open/Closed, Battery Reverse, No Battery, Battery Float
Charging, Battery Boost Charging.
d)
Inverter:
Inverter Over-Current, Inverter Asynchronous, Inverter Fault, Inverter
inductor over-temperature, Inverter Over-Temperature, Inverter communication
Fail, Inverter STS Fail, Inverter DC Offset, Inverter in Setting.
e)
Bypass:
Bypass STS Fail, Bypass unable to trace, Bypass Abnormal, Maintenance
Disconnect Open/Closed, Bypass disconnect open/closed, Bypass Abnormal
Shutdown, Bypass Phase Reversed, Bypass over-current
f)
Paralleling:
Parallel Board Fault, System Transfer, Parallel Communication Fail,
Parallel Connect Fault
g)
Module’s Common:
Normal Mode, Battery Mode, Bypass Mode, Ambient Over-Temperature,
Fan Fault, System Overload, Manual Turn-ON/OFF, Unit overload time-out,
Operation Invalid, Output Fuse Fail, Control Power 2 Fail, Unit overload, Joint
Mode, UPS Shutdown, Output disabled, Transfer confirm/cancel, Unit OFF
confirm, System OFF confirm, Fault Reset, Alarm Silence, Output Disconnect
Open/Closed, Turn-ON Fail, Output Over-Voltage (reserved), Alarm resent, Load
impact Transfer, Transfer Time-Out, Load Sharing Fault, Parallel ID Error, EPO,
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 102 of 118 Setting Save Error, Mains neutral Lost, UPS System testing, protocol version
Clash.
3.4
Power Status Diagram:
A mimic panel shall be provided to depict a single line diagram of the UPS.
Illuminating lights shall be integrated within the single line diagram to illustrate the status
of the UPS. The three LEDs shall indicate the following status.
A.
Bypass voltage OK
B.
Load on bypass
C.
Load on inverter
Controls:
The following controls have to be accomplished with the display unit:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
3.5
Silence an audible alarm.
Set the alphanumeric display language to English or the alternate language.
Display or program the time and date.
Enable or disable the automatic restart feature.
Transfer to or from static bypass operation.
Transfer to or from forced battery operation.
Program the unit for economy operation.
Program the battery charger.
Calculate battery back-up time.
Test battery condition on demand.
Program the unit to periodically test battery condition.
Program voltage and frequency windows.
Calibrate metered parameters.
Enable or disable adaptive slew rate. Set maximum slew rate.
Adjust set points for different alarms.
Program the remote shutdown contact (enable/disable remote shutdown,
polarity display).
Set the delay of the common fault contact.
Program the unit for soft start for use with a generator.
Communication Features:
RS-232 / RS485 interface ports as standard feature
SNMP/HTTP Network Interface.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 103 of 118 MODEM Card.
3.6
Remote UPS Monitoring Kits:
Remote UPS monitoring must be possible via either RS-232 or contact closure of the
UPS.
3.7
SNMP adapter:
A Web-Enabled SNMP adapter for one or more network management systems
(NMS) to monitor and manage the UPS in TCP/IP network environments should be
available. The management information base (MIB) must be provided. The SNMP
interface adapter has to be connected to the UPS via the RS232 serial port.
3.8
UPS On And Off Switches:
Momentary UPS on and off Switches must be provided in a user accessible area.
Upon activation of the Switches, the UPS must automatically connect the UPS output to
the critical load. Upon de-activation of the Switches, the UPS must remove power from
the critical load.
3.9
Integral Maintenance Bypass:
The Integral maintenance bypass has to supply the load from the bypass source
while the UPS is isolated for maintenance. UPS input, output, static bypass and
Maintenance Bypass Switch must be housed in the same cabinet. Each switch must be
monitored and controlled by the UPS.
3.10
Battery charger temperature compensation:
For units with external batteries, the battery charger temperature compensator has
to monitor the temperature in one battery cabinet.
4.
ISOLATION TRANSFORMER
The isolation transformer should be three phase, naturally cooled type, housed in one
steel cubical provided with unidirectional cast iron wheels at bottom and lifting hooks at
the top. The cubical enclosing the isolation transformer should have doors on front and
rear side, bolted side covers and removable top cover.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 104 of 118 a. AC Input:
b. AC Output:
Delta 3-phase, 415 + 10% (phase to phase)
Star 3-phase, 415 + 10% (phase to phase)
230 (phase to neutral)
c. Frequency:
47 to 53 Hz
d. Capacity:
90 KVA 3-phase (30 KVA per phase)
e. Duty cycle and use
Continuous, Indoor
f. Common Mode Noise Rejection Better than 110 dB
g. Load regulation
<4%
h. Insulation resistance
More than 500 Mega Ohms at 500V
i. Terminals
Studs on fiber glass plate at rear
j. Cable entry
Bottom
5.
EVIRONMENTAL CONDITION
1. Operating Ambient Temperature 0OC to 45OC
2. Storage/Transport Ambient
-25OC to 55OC
3. Relative Humidity
upto 90%.
6.
Guarantee:
6.1
The supplier shall guarantee UPS and batteries for 36 months from the date of
supply. Any defect/ failure of equipment/component or assembly and non-performance in
this period are to be set right by the manufacturer free of costs at the premises of the
consignee. A certificate from all OEMs may be attached with the offer that they will
adhere to guarantee clause as above.
6.2. The UPS manufacturer shall directly employ a national field service network
staffed by factory trained field service engineers to provide start up, maintenance and
repair of the UPS equipment. Parts must be available through the service organization 24
hours a day, 7 days a week, 365 days a year.
6.3
The UPS manufacturer shall give the address of his local office/representative in
India to facilitate interaction. In case any module of UPS requires repairs at factory, the
same would be handed over to his Indian representative in India, who would arrange
export of module to factory and re import in India after repairs/replacement. After sales
service for maintenance and repairs in India is an essential requirement of this tender
without which the offer may be rejected.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 105 of 118 Annexure I-17
1. SPECIFICATION
OF
DSETC
OF
TRANSMITTER
CONTAINER/SHELTER FOR HOUSING TV TRANSMITTERS INCLUDE
IND HEAT INSULATION, HEAVY DUTY BASE/ FLOORING 1.5 TON
/SQM, FLOORING TILES, DOORS , WINDOW, FALSE CEILING,
FINISHING, PAINTING ( COLOUR & SHADE DESIGN AS PER SITE
REQUIREMENT) & INTERNAL ELECTRICAL WORKS OF LIGHT&
POWER, LIGHT & POWER COPPER WIRING. VENTILATION UNITS
COPPER WIRING, SWITCHES, SOCKETS, MCBS, ILLUMINATION
FITTINGS, CONTAINER EXTERNAL LIGHTS & GATE LIGHTS
FITTINGS, AUTOMATIC FIRE ALARM SYSTEM ETC COMPLETE AS
PER SITE CONDITION
2. SPECIFICATION
OF
DSETC
OF
POWER
SUPPLY
CONTAINER/SHELTER FOR HOUSING POWER SUPPLY EQUIPMENT
UPS , LT BOARDS, INCLUDING HEAT INSULATION, HEAVY DUTY
BASE/FLOORING 1.5 TON /SQM, FLOORING TILES, DOORS ,
WINDOW, FALSE CEILING , FINISHING, PAINTING ( COLOUR &
SHADE DESIGN AS PER SITE REQUIREMENT)&
INTERNAL
ELECTRICAL WORKS OF LIGHT& POWER, LIGHT & POWER
COPPER WIRING, SWITCHES, SOCKETS, MCBS, ILLUMINATION
FITTINGS, CONTAINER EXTERNAL LIGHTS & GATE LIGHTS
FITTINGS, AUTOMATIC FIRE ALARM SYSTEM ETC COMPLETE AS
PER SITE CONDITION
1.
Introduction:
CONTAINER/SHELTER
FOR
HOUSING
TV
TRANSMITTERS: Tender is required to work out the size as per the layout of
transmitter equipment and tentative dimensions of equipment along with all
Broadcasting, telecasting & O&M requirement. A detailed equipment layout
plan drawing showing the Transmitter racks, Input/Monitoring/Measuring
Equipment Racks, 7 ports Patch panel, Pump Rack, Combiner, dummy load,
dehydrator, Power supply Equipment etc. installed in the equipment container
must be attached with the offer.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 106 of 118 2.
Same specification as given below is to be referred for both containers/ shelters for
housing transmitter equipment & power supply equipment.
3.
CONTAINER/SHELTER FOR HOUSING POWER SUPPLY EQUIPMENT:
Tender is required to work out the size as per the layout of power supply
equipment and tentative dimensions of equipment along with
all CEA
regulatory O&M requirements.
4.
Scope: This specification is for design, manufacturing/fabrication, supply,
transportation and installation of container/shelter to be installed at various places
of Indenter in J&K Site. These shelters are meant for mobile application & should
be suitable for transportation through rail, road & air . These are used in the field
under severe weather & physical condition. A drawing specific to each shelters /
shelter should be submitted by the tenderer.
5.
Information to be supplied with the tender:
a) A Compliance Statement to the complete specification of indenter, para wise,
for each clause.
b) Complete printed technical literature/data sheet/ detailed information
including technical
manual (if any) of Container/shelter from the Original
Equipment Manufacturer (OEM) in support of compliance statement should be
furnished for all the items of the tender, to assess the full merit of the offer, without
which the tender will be considered incomplete and is liable for rejection
c) Descriptive information giving complete details of container/shelter offered.
d) Detailed Schedule of Requirement/Materials offered for SETC of the
container/shelter should be in conformity with Part 4.0 without any change in
format without price (un-priced) failing which the tender shall be considered
incomplete and will be liable for rejection. The tenderer must quote all items.
e) Country of origin, make, type, model number in respect of all items should be
submitted along with the name & address of their vendors.
f) Layout and construction details of container/shelter including dimensions,
weights, overall sizes and photographs of the interior of the container/shelter. This
should include tentative accommodation plan with Plan, front elevation, back
elevation , side view for each container/shelter separately, failing which the tender
shall be considered incomplete and will be liable for rejection..
g)
Complete drawings with a sections, structural details with list of all
hardware material as per IS amended up to date of container/shelter separately as
per specification are to be submitted with the offer.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 107 of 118 6. Guarantee : The cabin will be guaranteed and a general undertaking to accept the
guarantee will be furnished by the tenderer that:
1. the shelter supplied will be in accordance with these specifications, varied only
to the extent stated in tender’s offer and agreed to in the contract.
2. to make good within 30 days at tenderer expense any component which
becomes defective under normal operating conditions during 18 months
from the date of acceptance of the equipment at respective site or 12
months from the date of commissioning at site whichever is earlier.
7 REQUIREMENTS
7.1 Operating and environmental conditions
The shelter should withstand, without damage, the following environmental
conditions and remain fit for its intended use after being exposed to such
condition. Some of the stresses may be simultaneous.
7.1.1 Temperature : -10°c to 50°c
7.1.2 Wind speed: Operational : 70 Km per hour
Wind speed : Survival : 150 Km per hour
or as per IS/CPWD specification which ever is higher
7.1.3 Sealing: During storage, transit and operation, the shelter should be rainproof (with
the opening fitted with. Shutters as applicable). All exposed
seals and edges should be assembled so as not to absorb nor
retain humidity.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 108 of 118 7.1.4 Electric field
: The screening should be sufficiently effective to provide a
60 dB minimum electric field attenuation, in the frequency
range of 1500 KHz to 1000 MHz.
7.1.5 Atmospheric:
It should be able to with stand as site condition.
7.2 Panel construction
The shelter shall be fully enclosed and thermally insulted. All Panels should
essentially be free from corrosion, dents scratches and gouges. The facing should
preferably made of sheets without joints. These should be flat aluminum alloy sheets,
free from corrosion, dents, scratches and other similar defects. The aluminum sheets
should not be affected by natural causes like humidity, rain, atmospheric heat and
dust.
Design of shelter/ container should be withstand the wind speed 198 km/hr.
7.3 Other features
All the joints should provide sealing against ingress of moisture in to the panel and
the interior of the shelters. Each shelter should be provided with a main entrance door
and an emergency hatch on main door . The door should be made of same material as
that of the wall panel. All doors should be with round corner. The electrical continuity
between the cabin doors and panel should be ensured by providing RF shielded
gasket. The electrical continuity with door open should be ensured by earthling braid.
One safety lock with three key should be supplied with main door, the emergency
hatch should be operable from inside by means of special accessory clipped on to the
hatch door.
The door locking bar should be possible to the operated by handles provided on both
inside and outside handles. The hinge fixing should be done in such that the rigid
skids can be replaced by flexible skids when application from outside.
The shelter should be provided with skids which are screwed on to the bottom on
the shelter. The pitch of the fixing screws should be such that the rigid skids can be
replaced by flexible skids when application so warrants.
The internal and external metallic skin of the panels should be electrically
continuous independently and electrically separated from each other except at one
point where they are connected together and grounded resulting in double
electrically isolated construction.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 109 of 118 8 CONSTRUCTION REQUIREMENTS:
8.1
Metal and mechanical Assemblies
Mechanical assemblies should be designed and protected against electrolytic
corrosion. Metal parts should bear no marks of corrosion, blisters, chips or
scratches.
8.2
Nuts and Bolts
The nuts and bolts used should meet the requirements of the ISI standards. Nuts
and bolts used should be Either stainless steel or steel hot dip galvanized .
8.3 Insulating Materials
The insulating material should be suitable for thermal /heat insulation as per site
condition.
8.4 The dimensional details, features and special load bearing requirements should be
capable to bear the load of 2 Nos. of 5 kW UHF TV Transmitters and their auxiliary
equipment setup with the safety factor of 1.5.
9:
Structure and material:
9.1 Material: All the material used in the construction of the container/shelter will
be ISI marked and as per approved structural drawings of the structural design
agency/ Institute as mention in Para 5.2. The material in totality required shall be
designed as per site terrain , loading requirement including the factor of safety
better than 2 (two) under the worst conditions
9.2 Safety and structural design: The strength of the structure of
container/shelter base support, sides wall panels, roof , flooring etc shall be able
to withstand wind velocity as mentioned in clause 3.0 as above or as per
CPWD/IS specifications as applicable at the site or which ever is higher.
Structural design of container/shelter under worst atmospheric conditions and
terrain shall be better than 2(two) and shall be got approved from IIT/SERC by
the tenderer.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 110 of 118 10 General:
(i) Civil heavy duty flooring
(ii) Heat Insulation
(iii) Flooring tiles
(iv) Doors, windows, false ceiling
(vi) Finishing, painting (design and shade as per site requirement)
like entrance sliding steel door from out side and sliding aluminum gate
from inside, Double glass airtight windows of anodized aluminium with aluminum grill
along with glass, handle lock, U-channel etc.
11 Electrical work:
11.1 Electrical fittings and other accessories etc. : The quantities of items may
vary as per actual site requirement.
(i) Recessed type twin fluorescent 4´×40 W, mirror optic decorative fitting
(ii) Container outside lights/Gate lights
(iii)
MCBs for Light & power installation
(iv)
SP&N, MCBs with industrial socket and metal box with
frames
steel
(v) Light points, power points, light sockets etc.
(vi)
Automatic fire alarm system.
11.2 Electrical Switch gear etc. along with protection short circuit, over load &
earth fault. Rates for above items will be quoted separately item wise by the
tenderer.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 111 of 118 11.3 Electrical Wiring: Light Points wiring, power point wiring ,circuit wiring,
submain wiring and wiring for Ventilation equipment shall be carried out with
copper wiring stranded conductor as per IS/ CPWD specification amended
uptodate.
12 Working and life:
The workmanship of the proposed container structure will have a very good finish
and should reflect the skilled workmanship. The life of the structure shall not be
less than 50 years. The various tools and miscellaneous items required for the
installation of container will be arranged by the tenderer himself. Painting on wall
panels, windows etc. of the container will be done by the tenderer with two coats
of paint. Paint will be ISI marked. Colour of paint will be decided by zonal
office.
13
Inspection of site: The container as per the suggestive specification will be
constructed by the firm at site. Transportation and other charges for the installation of the
container etc. at site are the part of the tender and no extra payment shall be made on this
account.
(A) Electrical Installation points details of transmitter container
S.NO.
DESCRIPTION
QUANTITY^^
1.
5 Amp light point 8
nos,2x40 watt
8 nos
2.
5 Amp plug point 4 nos
x100 watt
4
3.
Cabin floodlight points/
gate light
5
5 nos x 100 watt
4.
20 Amp MCB with
Industrial Socket
including Metal box
frame complete for
ventilating units.
5
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 112 of 118 (B)Electrical Installation points details of power supply container
S.NO.
DESCRIPTION
QUANTITY^^
1.
5 Amp light point 6
nos,2x40 watt
6 nos
2.
5 Amp plug point 4 nos
x100 watt
4
3.
Cabin floodlight
points/gate light
5
5 nos x 100 watt
4.
20 Amp MCB with
Industrial Socket
including Metal box
frame complete for
Heaters
5
^^ Quantity may vary as per size on container.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 113 of 118 Annexure I-18
Specifications for Audio Analyzer
1.
SCOPE:
The Audio Analyzer should be a precision instrument, suitable for making direct
Audio measurements of a "T.V. Transmitter system". It should be capable to monitor all the
Audio parameters of a Analog TV Transmitter system. It should also have the up gradation
facility for measuring digital parameters.
2. Features and Measurements required:
2.1 Analog Audio measurement functions: Instrument must have the facility to measure the
following Analog audio parameters of an Analog TV Transmitter(i) Level
(ii) Cross talk
(iii) Frequency
(iv) Total Harmonic distortion
(v) Noise
(vi) Wow and Flutter
(vii) Drift
(viii) Inter modulation Distortion
(ix) Narrow band selective level
(x) Spectral FFT analysis
2.2 Digital Audio measurement functions: Instrument must have the up gradation facility to
measure the following Digital audio parameters of a Digital TV Transmitter (DVB-T2
Standard):
(i) Carrier Level
(ii) Sampling Frequency
(iii) Jitter Analysis
(iv) Peak level
(v) Bit statistics
(vi) Status Analysis
3.0
SL.
NO.
1.
Technical Specifications:Parameters
Values
Standard
PAL B/G colour standard for Analog and DVB-T2 for
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 114 of 118 Digital
2.0
2.1
2.2
2.3
3.0
3.1
3.2
3.3
3.4
3.5
3.6
General Data
Operating Temperature
Range
Humidity
Power Supply
Audio Inputs/Outputs
Connectors
Frequency Range
Frequency response from
20 Hz to 20 KHz.
(Referenced to 1 KHz)
Common Mode
Rejection at 1 KHz
Harmonic Distortion
(a) Fundamental
Range
(b)
Maximum Input Voltage
0 to 45ºC
10% to 90% (Non conditioning)
230V ± 10%
BNC, two channels simultaneously operating.
10 Hz to 80 KHz.
±0.05dB
≥ 75 dB
20 Hz to 20 KHz
33 Volt rms
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 115 of 118 Annexure I-19
I. SPECIFICATION OF AMPLISPEAKER
The system should be high grade transducer of professional audio monitoring quality.
Unit must have an ON/OFF switch with LED indication and a level control.
Transducer components like Woofer and Tweeter must be magnetically shielded.
Technical SpecificationsSr. No.
1.
2.
3.
4.
5.
6.
7.
Description
Power Supply
Amplifier power without clipping
S/N ratio
Gain control range
Volume control range
CMRR
Protection
Parameters
230VAC±10%, 50Hz.
LF-45W, HF-45W
>90dB
±6dB
>70dB
>65dB
Over current, Over
heat, RFI, Switch
On/Off transients.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 116 of 118 Annexure I-20
Specification for R.F. Power Meter with sensors
1.
SCOPE:
The RF power meter is required for measurement of RF power of modulated signal. It should
be a sensor based power measurement device having a good dynamic range. The equipment should be
rugged in construction, light weight and easy to operate. The equipment must be supplied with the
accessories like power cord, fuses and manuals.
2.0 Technical Specifications:SL.
NO.
1.
2.
3.
3.
4.
5.
6.
7.
Parameters
Values
Power measurement
Power measurement
Range
Operating Temperature
Range
Storage Temperature
Range
Power Supply
Frequency of operation
Number of readings
Dynamic Range
Average power
-67dBm to +44 dBm
0 to 45ºC
-20 to 60ºC
230V ± 10%, Frequency 50 Hz
Up to 1GHz
Up to 200 readings per second
90 dB
The RF Power meter must be supplied with the power sensors to measure the power in the
above specified range.
DGDD/TxD/5kWHPT Specs/J&K/2010 Page 1 of 118 DGDD/TxD/5kWHPT Specs/J&K/2010 Page 1 of 118 ANNEXURE-III
7 Port Patch Panel - Details
To Antenna (10kW)
from
Tx2
5kW
Comb in 1
(5kW)
Comb in 2 (5kW)
from
Tx1
5 kW
Comb out (10 kW)
To Dummy Load (10 kW)
Notes:
1. U Links between Tx1 to Antenna, Tx2 to Antenna, Tx
1 to Dummy load, Tx 1 to Comb in 1, Tx 2 to Comb 2
in are of same size.
2. U Links between Comb out to Antenna and Combiner
out to Dummy load are of same size.
3. The above to sets out U links (as given in 1 & 2 above)
MUST BE of two different sizes.
DGDD/TxD/5kWHPT Specs/J&K/2010 