GENERAL MANUAL
ADVANCE 88
A COMPANY WITH
CERTIFIED SYSTEM OF
QUALITY ISO9001
IST0439V6.0
-1-
Summary
TECHNICAL CHARACTERISTICS ........................................................................................................................................... pag. 3
Distribution of the zones in the control unit ADVANCE 88 ......................................................................................................... pag. 4
BALANCED ZONES ................................................................................................................................................................. pag. 4
DOUBLE RESISTOR CONFIGURATION (zones with alarm tamper signalling) ........................................................................ pag. 4
DOUBLE ZONES ..................................................................................................................................................................... pag. 5
KEYPADS ................................................................................................................................................................................ pag. 6
Collegamento A600 Plus - ADVOICE ....................................................................................................................................... pag. 7
SATELLITES ............................................................................................................................................................................ pag. 8
TAMPER INPUT ....................................................................................................................................................................... pag. 8
Power Supply Unit Section ....................................................................................................................................................... pag. 9
CONTROL PANEL BOARD ................................................................................................................................................... pag. 10
OPEN COLLECTOR OUTPUTS (O.C.) ................................................................................................................................. pag. 10
PULSE MODE CONCERNING REMOTE ARMING ................................................................................................................ pag. 11
REMOTE ARMING ( a stato) .................................................................................................................................................. pag. 11
LOGICOM - Technical characteristics .................................................................................................................................... pag. 14
GSM Plus - Caratteristiche tecniche ....................................................................................................................................... pag. 15
LOGICOM + GSM Plus .......................................................................................................................................................... pag. 16
SIM Card Insertion/Antenna Connector Entry ......................................................................................................................... pag. 16
Credit Control ......................................................................................................................................................................... pag. 16
Setup of Sim Card Expiry ....................................................................................................................................................... pag. 16
Vocal synthesis board ............................................................................................................................................................ pag. 17
Vocal messages .................................................................................................................................................................... pag. 18
Phonetics Chart ..................................................................................................................................................................... pag. 19
INSTALLER RTC ACTIVATION ............................................................................................................................................... pag. 20
INSTALLER DTMF COMMANDS ............................................................................................................................................ pag. 20
RTC function (Remote Telephone Check ) ............................................................................................................................. pag. 20
USER RTC with recognition of incoming number ................................................................................................................... pag. 20
USER DTMF COMMANDS ..................................................................................................................................................... pag. 20
SOME NOTES CONCERNING SECTORS (PARTITIONS) AND ARMING MODES ................................................................ pag. 21
PROGRAMMING .................................................................................................................................................................... pag. 22
INSTALLATION ....................................................................................................................................................................... pag. 22
SECTORS ............................................................................................................................................................................. pag. 23
ZONES .................................................................................................................................................................................. pag. 24
IMPULSIONS .......................................................................................................................................................................... pag. 25
O.C. zone .............................................................................................................................................................................. pag. 25
OPTIONS ............................................................................................................................................................................... pag. 26
Second profile ....................................................................................................................................................................... pag. 27
ARMING ................................................................................................................................................................................. pag. 28
TAMPER ................................................................................................................................................................................ pag. 28
FIRE ...................................................................................................................................................................................... pag. 29
RELAYS ................................................................................................................................................................................. pag. 29
SIRENS ................................................................................................................................................................................. pag. 29
OPEN COLLECTOR ............................................................................................................................................................. pag. 30
TIMING PROGRAMMING ........................................................................................................................................................ pag. 31
SERVICE CODE .................................................................................................................................................................... pag. 32
USER CODES ....................................................................................................................................................................... pag. 33
USER PROFILES .................................................................................................................................................................. pag. 33
KEY ....................................................................................................................................................................................... pag. 35
KEYPAD ................................................................................................................................................................................ pag. 37
RADIO EXTENSION BOARD ................................................................................................................................................. pag. 38
LABELS: zone, codes, Open Collector ................................................................................................................................... pag. 39
PROGRAMMING TIMER ........................................................................................................................................................ pag. 40
PROGRAMMING DIALLER ..................................................................................................................................................... pag. 42
PROGRAMMING DIALLER ..................................................................................................................................................... pag. 43
COUNTRY ............................................................................................................................................................................. pag. 48
LANGUAGE ............................................................................................................................................................................ pag. 48
EVENTS MEMORY ................................................................................................................................................................ pag. 48
EEPROM Reset ..................................................................................................................................................................... pag. 48
Codes Reset .......................................................................................................................................................................... pag. 49
MENU’ STANDBY ................................................................................................................................................................... pag. 49
EPROM VERSION ................................................................................................................................................................. pag. 49
Products must be used according to foreseen destination and in conformity to the norms concerning various
methods of installation. Anyway, before putting the system into service, it will have to be tested in order to check
functionality and respect of security norms according to Law n. 46 dated 05/03/90 and norms CEI 79-3
Do not drip or water sprinkle on device. Do not place anything containing water on it.
AVS Electronics S.p.A. has the right to modify the product at any time with no warning
-2-
TECHNICAL CHARACTERISTICS
ADVANCE 88 is a microprocessor control unit pre-arranged for the connection to voice-synthesis and digital telephone dialler.This
technologically avant-garde unit satisfies the latest international standards. It is the ideal control unit for medium sized systems,
with complete management by means of remote keypad, easy to program and user friendly.The state-of-the-art of the
communication system ASSC and RTC allows a really and complete integration among the security system, the protected
environment, the telephone connection and the end-user.The system has constituted from the control unit and from the at least
one keypad model A600 - A600 Plus (until to a maximum of 8 keypads) and could be completed with extension satellites (model
SAT03, 04,SATWS) with the telephone digital dialler (LOGICOM) and or GSM dialler (GSM Plus) and with the vocal module
(EUROSINT88). NOTE: The numbers proceeded from a “(+...)” between parenthesis, are referred to the outputs of the satellites or
characteristics of the control unit.
Keypads:
•
Zone extensi ons:
Seri al proxi mi ty key:
Zones:
•
•
•
Zones confi gurati on:
•
•
•
•
•
•
Zone opti ons:
•
Memory events:
Alarm output:
•
•
Sectors (parti ti ons)
•
Armi ng:
C odes
•
•
•
•
•
•
•
Automati c clock program:
•
•
•
•
•
•
•
Supply C ontrol:
•
Opti onal modules:
•
•
Programmi ng:
•
•
•
•
•
•
•
•
•
Supply Voltage:
D i mensi ons:
Envi ronmental condi ti ons:
C urrent consumpti on [max] from the net
230 V ~
C urrent consumpti on absorbed on 12VAvai lable current
•
•
•
up to 8 LC D keypads on max 600 mt of cable
backli ghted di splay and rubber buttons
up to 4 extension satellites (mod. SAT03, SAT04 o SAT WS)
up to 8 seri al proxi mi ty Key (EB3/RS) on max 600 mt of cable
n° 10 (+10) i ndependently programmable wi th automati c detecti on of the two di fferent
alarm status (zone tamper + zone alarm.)
Each si ngle zone can be programmed i n 13 di fferent zone types
n° 1 dedi cated tamper balanced i nput (not by passable)
n° 1 balanced i nput (wi th max 4) on A600 - A 600Plus keypad
n° 4 (parted sectors (parti ti ons)
n° 1 (common sector (parti ti on)
No t us e d - Ins t a nt - 2 4 ho ur s - D e la y ( T1 - 2 - 3 ) - C o nd i t i o na l - Ins t . p e r m e s c . Inst.temp.esc.- D elay wi th permanente esclusi on (T1-2-3) - D elay Ti mi ng wi th temporany
esclusi on (T1-2-3) - 24 hour D elay (T1-2-3) - 24 hour wi th prealarm (T1-2-3-4) - 24H
prealm. (T1-2-3-4) - Istant wi th prealarm (T1-2-3-4) - Tamper - Key AREA - Key HOME
- Key ON
pulse programmi ng, alarm and restore memori zati on, tamper si nalli ng, chi me functi on,
door functi on, ZONES i n TEST functi on, acti vati on of alarm relay (control uni t), acti vati on
of addi ti onal relay (satelli tes), acti vati on of si ren dri ver output (satelli tes), acti vati on of
the keypad’ buzzer i n alarm status, acti vati on of O.C . output, AND zones (max 6 zones,
by groups of two), di recti onal AND , zones text of 16 characters, alarm counter
Memori zati on of the latest 250 events (wi th date and ti me)
n° 1 (+4) programmable alarm relay, (two exchange-over contacts, posi ti ve securi ty)
n° 8 (+32) transi stori zed outputs (50 mA - Open C ollector) on termi nal blocks, for the
connecti on wi th relay module (mod. MR 4/MR 8).
n° 1 transi stori zed output (100 mA - Open C ollector) on termi nal blocks dedi cated to the
Tamper li ne
n° 1 transi stori zed output (50 mA - Open C ollector) on termi nal block dedi cated to the
control panel FAIL
n° 3 di fferent armi ng modali ti es
From keypad or from external acti vati on i n modali ty ON, HOME and AREA
n° 64 USER C OD Es are avai lable, from 4 to 6 di gi ts
each USER C OD E can be i ndependently associ ated to 8 different profiles. Profi le
i s the attri bute of a code.
For each USER C OD E i s avai lable an Emergency C ode)
Programmable on weekly base
12 dai ly operati ons i ndependently programmable
10 holi days programmable peri ods
Possi bi li ty of overti me peri od acti vati oni
automati c change of summer-wi nter ti mee
Possi bi li ty of di sabli ng of the USER C OD E, when the uni t has been acti vated from the
automati c clock
automati c Acti vati on of the buzzer before the automati c armi ng of the control uni t
si gnali ng (on di splay) of low or lacki ng battery and lack of the supply from the mai ns or
anomali es, also of the addi ti onal Power Supply Uni ts (Po w er 1Q, Po w er 4Q )
di gi tal telephone di aller (mod. Logicom) or GSM di aller (mod. GSM Plus)
vocal synthesi s board (mod.Eurosint88)wi th one recordable message of i ntroducti on
+ pre-recorded message + RTC (remote telephone control) functi on to be i nstalled wi th
board (mod. Logi com)
From LC D keypad wi th dri ven menu
From PC i n di rect connecti on wi th WIN R EC software and XS40U
From PC i n telephone connecti on wi th WIN R EC software and XM40Plus
stabi li zed ali mentati on: 13.8 VKeypad: 170 x 120 x 35 mm
Metal housi ng:(LxHxP): 355 x 340 x 110 mm
Metal housi ng: H (LxHxP): 355 x 455 x 150 mm
+5 °C / + 40 °C
(270 mA) wi th total current consumpti on from control uni t of 1.5 Amp
(only control panel): 80 mA
wi th battery 7Ah: 900mA / wi th battery 12Ah: 700mA
-3-
Distribution of the zones in the control unit ADVANCE 88
• the zones of ADVANCE 88 are numbered in the following order:
1
11
2
12
3
13
4
14
1
2
3
4
5
15
6
16
7
17
8
18
9
19
10
20
If used the “double zones”
Connected on A600 - A600 Plus
• the zones of the Satellites (1) are numbered in the following order:
25
33
26
34
27
35
28
36
29
37
30
38
31
39
32
40
With EXPEURO
• the zones of the Satellites (2) are numbered in the following order:
41
49
42
50
43
51
44
52
45
53
46
54
47
55
48
56
With EXPEURO
• the zones of the Satellites (3) are numbered in the following order:
57
65
58
66
59
67
60
68
61
69
62
70
63
71
64
72
With EXPEURO
• the zones of the Satellites (4) are numbered in the following order:
73
81
74
82
75
83
76
84
77
85
78
86
79
87
80
88
With EXPEURO
BALANCED ZONES
ADVANCE 88 has a basic configuration of ten balanced zones, with end of line resistor of 4,700 ohm.
This is the simplest configuration of the zones of the control unit.
The opening or the short-circuit of a zone, is giving an alarm signalling.
It is not possible, in this case, the detection of the tamper alarm, (using the same wires of the line), so that
the tamper must be connected to the dedicated TAMPER input (or using a zone programmed as TAMPER).
The colours of resistor R1 are:
R1 4.700ohm
1) Yellow Value: 4
2) Violet Value: 7
3) Red: Number of zeroes: 2
4) Gold: Tolerance: 5%.
The dedicated Tamper input is always balanced with a single end of line resistor
DOUBLE RESISTOR CONFIGURATION (zones with alarm tamper signalling)
This configuration allows receiving the zone alarm and the tamper alarm of each zone, using the same two
wires.
The lines programmed in this formality must be ended with two end of line resistors from 4,700 ohm. The first
resistor identifies the alarm of line, while the seconds the tampering.
Doing reference to the figure, open the contact, the control panel is detecting the alarm status, while the shortcircuiting or the cutting of the line is detected (also with the system disarmed) as tamper alarm.
The selection of the double resistor configuration can be done line by line (see Chapter 27).
The dedicated Tamper input is always balanced with a single end of line resistor
LINES NOT USED must be however BALANCED
Example: connection of two detectors to two different zones using the two resistors configuration.
The opening of the contact n.c. ALARM, provokes an alarm status.
The opening of the contact n.c. TAMPER or a short-circuit, provokes the tamper alarm of the
corresponding zone.
The colours of resistor R1 are:R1 4.700ohm
-4-
DOUBLE ZONES
ADVANCE 88 allows to duplicate the number of the zones (from 10
to 20 zones), without the addition of external modules.
To obtain this, program the option “Double Lines” .
Selecting this modality, each single zone’ input is doubling in two
different zones:
Example: The zone input L1 will correspond now to the lines L1 and
L11. This concept is valid for the other zones, so that we will obtain
a sort of “twin” zones.
The 20 zones are, to all the effects, independent among them.
Summarize:
Programming Double Zones (No) you will obtain an installation
type “Balanced Zones” and “Lines with signaling of Tamper” (max
10 zones).
Programming Double Zones (Yes) you will obtain an installation
type “Zones with signaling of Tamper” and “Double Zones” (max 20 zones).
The Double Zones configuration requires a balancing with three end of line resistors, as shown in the figure.
End of line resistors:
R1 - 4,700 ohm (4K7)
R2 - 10,000 ohm (10K)
The colours of the resistors R1 and R2, are:
R1 - 4.700ohm
1)
Yellow Value: 4
2)
Violet Value: 7
3)
Red: Number of zeroes: 2
4)
Gold: Tolerance: 5%
R2 - 10,000 ohm
1)
Brown Value: 1
2)
Black Value: 0
3)
Orange: Number of zeroes:
4)
Gold: Tolerance: 5%
In the Detector 1, when the contact is open (C-NC) in parallel to
resistor R1, you will get an “Alarm Zone 1.”
In the Detector 11, when the contact is open (C-NC) in parallel to
the resistor R2, you will get an “Alarm Zone 11.”
If they are open together, you will get two different alarm signalling.
The Tamper signalling can be independently activated for each of
the zones (1 to 10) and of the respective twin zones (11 to 20)
If the zone is short-circuited or open, you will get the signalling of
TAMPER alarm of the two zones (e.g. 1 and 11) if the “Tamper Signalling” has been programmed for each of these zones. Otherwise
you will obtain the Tamper alarm of the activated zone.
The use of the Double Zones, will increase the sensibility of detection of each single input.
-5-
KEYPADS
-
For the connection of the keypads must be respected the indications of the following
scheme, connecting the output of the serial BUS RS485 of the control unit, to the corresponding terminal blocks of the keypads.
- Different keypads can be connected, in parallel, on the same line (up to 8 keypads).
- The suggested section of the shielded cable is of 4x0.5mm.
- Total length of the RS 485 connection cable must be of (max) 600 meters (divided for
all the connected keypads).
- The positive supply of the serial BUS RS485 is protected from the fuse F1 (2A 250V).
Important Note
the back tamper against wall removal, is already connected and cannot be by-passed:
it is recommended, therefore, to pay attention inserting the spring that is pressing the
tamper button and close carefully the keypad.
During the first supply of the keypad the tamper button must be pressed, otherwise the
keypad is not initialized, giving a Tamper alarm signalling.
To exclude completely the tamper button, close bridge S-2 on the KEYPLUS board.
To esclude completely the tamper button, put in ON dip 5 on A600-A600 Plus board
DB DA +
Keypad address settings
If in the installation there are more then one keypad, the installed keypads must be address using the
dipswitch, place on the keypad board.
The numeration of the keypads must be progressive.
For instance.
...if installed n° 2 keypads,
the first keypad will have “address 0” and the second “address 1.”
Address setting
keypads
Keypad 1 (0)
Keypad 2 (1)
Keypad 3 (2)
Keypad 4 (3)
Keypad 5 (4)
Keypad 6 (5)
Keypad 7 (6)
Keypad 8 (7)
Dip
Dip
Dip
Dip
1
Off
On
Off
On
Off
On
Off
On
2
Off
Off
On
On
Off
Off
On
On
3
Off
Off
Off
Off
On
On
On
On
4
Off
Off
Off
Off
Off
Off
Off
Off
Positioning the dip according to the diagram, keypads are addressed.
Pay attention that it is not possible have more keypads with the same address,
otherwise they will stop work and the control unit will activate a tamper alarm.
In this case, for restore the operation, you must do:
a)
give the correct address to the keypads.
b)
remove and supply the power to all the keypads.
! Warning
In the control unit programming, you must program the number of the keypad(s)
installed.
Pressing simultaneously the keys (CLR) and (ESC) it is possible verify the correct address.
Zones connected on Keypad
Connect zones on keypad using R1 (4K7) (look at “Balanced zone”/”Double resistor configuration”).
LINES NOT USED must be however BALANCED
Table
Zone
21
22
23
24
Keypad
1-5
2-6
3-7
4-8
-6-
Connection A600 Plus - ADVOICE
F1A L 250V
S2
F3
F4
F2A L 250V
F3.15A L 250V
take away supplying to the system
plug-in vocal module onto the connector in control panel
connect SPK terminal of A600Plus to OUT SPK terminal of vocal module (Mod. ADVOICE)
supply the system
F2
-
FA
TA
J1
18V~
RS 485
D D
A B
L L
1 2
L I N E E 1 - 10
SENS
L L L L
L L L L T T
3 4 5 6
7 8 9 10
ALARM
S
N N
A S C C O
toward
other keypads
ADVOICE
- ADVOICE (one each system)
This accessory is necessary in
order to allow A600Plus audio
communication.
- For audio-communication of
A600Plus keypads, the installation
of Logicom or GSM Plus as well as
vocal module EUROSINT 88 are
required .
If the telephone interface (LOGICOM/
GSMPLUS) is not installed, close
jumper S2
Note: do not close jumper if at least
one interface is present
Enabling of Audio-communication on keypads (end-user)
To enable audio-communication on keypads, follow these steps:
- dial user code with attribution Master and enter menu 1 of the keypad you wish to enable
- scroll the programming steps until reaching “A600 setting”
- enter the menu and adjust “Audio Volume” on one of the possible settings (Mute - Low - Medium - High) by pushbutton CLR
Note: Mute de-activates any audio-communication of the keypad ( events and zone condition)
Enabling of Audio ZONES CONDITION of keypads (end-user)
To enable audio-communication ZONES CONDITION of keypads, follow these steps:
- dial user code with attribution Master and enter menu 1 of the keypad you wish to enable
- scroll the programming steps until reaching A600 settings
- enter the menu and set Audio Zones Condition on YES/NO by pushbutton CLR
Enabling audio EVENTS to the keypads ( installer)
To enable communication to keypads, follow these steps:
- set the telephone profile with Vocal Protocol
- set the telephone profile with Vocal A600 interface
- set Enable keypad events ; dial the number of the keypad, dial the number of te keypad to which you wish to send a virtual telephone call
e.g. set 1 to enable the call on keypad 1; set 137 for enabling the call on keypads 1, 3, 7;
set Þ to enable the call on all keypads
- the keypads will communicate all events associated to the telephone profile
Enabling of Audio ZONES CONDITION of keypads (installer)
To enable communication to the keypads follow these steps:
- set the telephone profile with Vocal protocol
- set the telephone profile with Vocal A600 interface
- set Enable Zones Condition Keypad; dial the number of the keypad to which you wish to send a virtual telephone call.
The keypads will communicate the opening of the inputs which are associated to the telephone profile (see example EVENTS)
Display Options and Rear-lighting (end-user)
It is possible to vary the contrast, the Led intensity and the rear-lighting . In order to vary these options, follow these steps:
- dial the user code with attribution Master and enter the menu 1 on the keypad you wish to enable
- scroll the proramming steps until reaching A600 setting
- enter the menu and scroll towards the bottom until reaching “Contrast Reduction - Led intensity reduction and Rear-lighting”
- Contrast reduction: setting YES, the display contrast is reduced
- Led intensity reduction: setting YES the keypad Led intensity is reduced
- Rear-lighting: (max 4) set the value (from 1 to 4) of rear-lighting intensity of display and keypad.
Interruption of vocal repetitions (end-user)
It is possible to cut down the cycle of vocal repetitions of the keypad
- dial pushbutton 3 on the keypad if you are in the user menu
- dial pushbutton 3 followed by ENT if you are outside the user menu
RTC enabling on A600Plus keypad
It is possible to activate the RTC directly on the A600Plus keypad with the same functions and use modes of RTC with telephone connection
Dial user code with attribution Master and press 7 (it has to be enabled in the “user profile”)
Follow the steps described in the user manual for RTC (page 23); press ESC to leave.
-7-
KEYPADS - A300 - A300Plus
L1 + DA DB
For the connection of the keypads must be respected the indications of the following scheme, connecting the output of the serial BUS RS485 of the control unit, to
the corresponding terminal blocks of the keypads.
- Different keypads can be connected, in parallel, on the same line (up to 8 keypads).
- The suggested section of the shielded cable is of
4x0.5mm.
- Total length of the RS 485 connection cable must be
of (max) 600 meters (divided for all the connected
keypads).
- The positive supply of the serial BUS RS485 is protected from the fuse F1 (2A 250V).
Important Note
the back tamper against wall removal, is already connected and cannot be
by-passed:
it is recommended, therefore, to pay attention inserting the spring that is
pressing the tamper button and close carefully the keypad.
During the first supply of the keypad the tamper button must be pressed,
otherwise the keypad is not initialized, giving a Tamper alarm signalling.
To exclude completely the tamper button, close bridge S-2 on the KEYPLUS
board.
To esclude completely the tamper button, put in ON dip 5 on A300-A300
Plus board
Keypad address settings
If in the installation there are more then one keypad, the installed keypads must be address using the
dipswitch, place on the keypad board.
The numeration of the keypads must be progressive.
For instance.
...if installed n° 2 keypads, the first keypad will have “address 0” and the second “address 1.”
Positioning the dip according to the diagram, keypads are addressed.
Pay attention that it is not possible have more keypads with the same address,
Address setting
otherwise they will stop work and the control unit will activate a tamper alarm.
Dip
Dip
Dip
Dip
keypads
1
2
3
4
In this case, for restore the operation, you must do:
Keypad 1 (0)
Off
Off
Off
Off
a)
give the correct address to the keypads.
Keypad 2 (1)
On
Off
Off
Off
b)
remove and supply the power to all the keypads.
Keypad 3 (2)
On
Off
Off
Off
!
Warning
Keypad 4 (3)
On
On
Off
Off
In the control unit programming, you must program the number of the keypad(s)
Keypad 5 (4)
On
Off
Off
Off
installed.
Keypad 6 (5)
On
Off
On
Off
- Pressing simultaneously the keys (CLR) and (ESC) it is possible verify the
Keypad 7 (6)
Off
On
On
Off
correct address.
Keypad 8 (7)
On
On
On
Off
Zones connected on Keypad
Connect zones on keypad using normally closed connection
the zones connected on A300 keypad have not the tamper
recognising
Zone
21
22
23
24
Keypad
1-5
2-6
3-7
4-8
-8-
DB DA + L1
SATELLITES
The extension satellites SAT03, SAT04 or SATW, are connected to the serial BUS RS485 of the control in the same way of the
keypads.
The satellites can be placed in AVS housings CONTSAT (Optional).
SAT 03
SAT 04
Extension satellites for zones with single or double balancing.
Input zones:
Outputs:
Options:
Connections
•
•
•
•
•
•
•
•
n° 8 balanced zones (or n°16 with ExpEuro) with tamper signaling (SAT03 and 04)
n° 1 zone for shock detectors (SAT03)
n° 1 tamper input
n° 1 dedicated fire input (SAT03)
n° 1 relay output (SAT03)
n° 1 siren driver (SAT03)
n° 8 optional open collector outputs (only SAT 03 / SAT W)
I n p u t f o r a d d i t i o n a l P o w e r S u p p l y Un i t ( P O W E R 1 Q , P O W E R 4 Q ) w i t h s e r i a l
communications of mains fail, low battery level and battery lack. (SAT03)
•
With four wires
•
•
•
•
Housing
CONTSAT
CONT SAT W
CONTEURO II
CONTEURO II H
Use of radio satellite mod. SAT WS makes IMQ certificate to decade
Addressing of Satellites (Additional information is in the Satellites’ manuals).
Addressing
satellities
Satellite 1
Satellite 2
Satellite 3
Satellite 4
Dip
Dip
Dip
Dip
1
Off
On
Off
On
2
Off
Off
On
On
3
Off
Off
Off
Off
4
Off
Off
Off
Off
The additional supply unit mod. POWER 1Q or POWER 4Q in box, must
only contain its transformer and back-up battery; only use minimum cable
necessary. RS485 serial MUST NOT transit through this box
TAMPER INPUT
All the Tamper protections (housing, sirens,.....) must be connected to the Tamper input having
care of install the Tamper kit against wall removal has indicated in the figure.
Note: the tamper alarm of the zones programmed with double resistors configuration is automatically detected from the unit.
FIXATION OF THE BOX
In order to be conform to the security norms EN 60950-1, the fixation to the wall
must be able to support a weight of 24 kilos.
Punti di fissaggio
Foro per Tamper
-9-
Power Supply Unit Section
The Power Supply Unit consist of an electronic board, stabilized at 13.8 V- and limited in current at 1.5A. The available current is
related to the battery used.
Fuse
F
F1
F2
F3
F4
Input Fuse 230V~:
F 2A L 250V
F 3.15A L 250V
F 2A L 250V
F 2A L 250V
250mA T - 250V
Protection of the positive output of the serial Bus RS485
Protection against the battery inversion of polarity
Protection of the positive supply of the zones 1-10
Protection of the positive tensions of the alarm section outputs (+, S.A. and+ S)
Table
Mains Supply:
Stabilized alimentation:
Current [max] consumption from the net 230 V~:
230V~ (+/-10%) 50Hz
with absorption of total current of 1,5A:
display Switch-ON:
display Switch-OFF
max A600Plus
display Switch-ON:
display Switch-OFF
A600 - A600Plus Keypad consumption
A300 - A300Plus Keypad consumption
min
max
ADVOICE consumption
5 mA
20 mA
Without load:
With maximum load:
Without load:
With maximum load:
external use:
Battery recharge
external use:
Battery recharge
Tension of exit to 230V~ (-10%)
Tension of exit to 230V~ (+10%)
Available current with battery from 7.0 Ah
Available current with battery from 12 Ah
13,8 V
270 mA
65 mA
170 mA
250 mA
40 mA
70 mA
13,8 V
13,2 V
13,8 V
13,6 V
900 mA
250 mA
700 mA
450 mA
Insert a multi-polar mains switch having a minimum distance of 3 mm. between the contacts, into the electrical system of the
building
Place a button-hole top on the ground wire and fix it to the threaded turret marked by the ground reference
The board of the control panel is connected to the ground via the metal turrets of the box
For the 230V supplying input, use double-isolated cables.
Toroydal transformer
The toroydal transformer is to connect in the
following way:
(1) Fase 220 V ~
(2) Neutro 220 V ~
(3) 18 V ~
(4) 18 V ~
(5) Shield H03VV 2 x 0.50
(6) Ground terminal
(7) Double-insulation shield
(8) Electronic circuit
(9) Fuse
Fixation of the toroydal transformer to
control unit:
For fixation use the bi-adhesive stripes given
within
Fix the bi-adhesive stripes onto the bottom of
the transformer and place it to control panel as
shown on the picture besides, pressing slightly.
- 10 -
CONTROL PANEL BOARD
ALARM OUTPUTS
S2
F4
F1A L250V
250V
F2AL
F2A L 250V
F3
F2
F3.15A L 250V
F1
F2A L 250V
8
7
6
5
4
3
2
1
USCITE ATTIVE
EPROM
S1
RESET
The control unit drives a relay
(positive security) with two
exchanges, completely free
from tensions.
The outputs marked as
ALARM are driven from a
relay (positive security), 2A at
12 Volts; this is normally
activated when the control
panel is in quiet status.
FA
TA
J1
18V~
+/+ S.A.
RS 485
D D
A B
L I N E E 1 - 10
SENS
L L L L
L L L L
3 4 5 6
7 8 9 10 T T
L L
1 2
ALARM
S
N N
A S C C O
protected output from fuse F4(2A 250V). It furnishes the supply for the recharge of the siren battery.
protected output from fuse F4 (2A L250V). It is the alarm command of the siren and it is giving a
positive when the unit is in quiet.
protected output from fuse F4 (2A 250V). It is the alarm command for the inside siren (12 Volts).
exchanges not supplied, completely free from tensions of the alarm relay (positive security).
C common exchange, NC exchanges normally closed and NO exchange normally open.
+S
[C] [NC] [NO]
OPEN COLLECTOR OUTPUTS (O.C.)
The control panel has 8 active transistorized outputs; they are given a negative, for connection with optional module (MR4 /
MR8).
To control panel
Output
1 2 3 4 5 6 7 8
J2
MR8 MA00320V1/0
J1
Supply input
1 S1 2
1 S2 2
1 S3 2
1 S4 2
1 S5 2
1 S6 2
1 S7 2
1 S8 2
X1 C1 X2 C2 X3 C3 X4 C4 X5 C5 X6 C6 X7 C7 X8 C8
Programmable and dedicated Open Collector outputs:
•
the open collector outputs from [n°] 1 to [n°] 40 are programmable; they can be activated from a programmed
event or from the activation of the end user.
NOTE: 8 O.C. are available on the main board, 8 for each satellite (SAT 3, SATW).
•
the open collector output (TA) is dedicated to the Tamper line; it is a positive security output and so it is giving a
transistorized negative that is disappearing in case of alarm of the dedicated Tamper input or when there is a Tamper alarm of
the zones.
•
the open collector output (FA) is reporting the status of the main board; it is a positive security output and so is giving a
transistorized negative that is disappearing in case of fail of the microprocessor.
- 11 -
Installation of the key
Further to keypad, the control panel can also be armed by an external actuator, by means of the zone inputs duly programmed
with arming in ON, HOME or AREA mode.
Control Panel Programming
Key Programming
Program as “pulse” or “status” according to the management desired.
Zone Programming
Program a zone as Key ON: (arming ON), thus unbalancing this terminal by a negative for a few seconds “pulse management”
or keeping the unbalance “status”, the control panel will arm in ON mode and the zones programmed as “included in ON” will
be considered as active. The same is worth for the zone programmed as HOME Key: (HOME arming) and for the zone
programmed as AREA Key (AREA arming) .
If the option “double zones” is enabled, the twin zone of the one used to command an arming in any mode, must have
configuration as “not used”. On the contrary, to warn about wrong programming, the keypad shows “Error prog. #1”
“Pulse” Management
The pulse management allows to manage the control panel via both keypad or electronic key.
Connection Scheme (mod. RK32 + mod.IMP32)
Electronic Key (mod.RK32 + mod. IMP32)
Jumper P3 open (it eliminates the delay of 60 seconds)
Jumper P4 in position B (the red Led is totally commanded by terminal
X)
Connect the terminal (X) to the output OC1 > “Arming Cat – YES for ON HO
AR – blk=YES” > bi-stable time > area #
Connect the terminal (P) to the output OC2 > “Cat.Area – Rebalancing” >
bi-stable time
“Status” Management
The “Status” management assumes the system management via electronic key only and uses the keypad only when an
arming is desired excluding the external reader (in case the electronic key is lost and you wish to exclude it)
ATTENTION: in this way, if the system has been armed previously by electronic key, it can only be disarmed by
electronic key
The resistances R1 in various pictures must have a value of 4.700 ohm
(Status) Connection Scheme RK32
Electronic Key (mod. RK32)
Jumper P3 open (it eliminates the delay of 60 seconds)
Jumper P4 in position B (the red Led is totally commanded by terminal X)
Connect the terminal (X) to the output OC1 > “Cat. Arming – YES for ON HO AR
– blk = YES” > bi-stable time
Connect the terminal (P) to the output OC2 > “Cat. Area – Rebalancing
The device of external command must be at least IMQ 2nd level and its
de-codification board must be placed inside the control panel. The non –
respect of this indication makes the IMQ certification to decade.
- 12 -
Connection Scheme/Programming of EB1 Key
DIP 1
(dip8:off)
DIP1
(dip8:on)
DIP 2
DIP 3
DIP 4
DIP 6
DIP 7
(dip8:off)
DIP 8
COD 2
( O FF) For c e d Ar ming: t he ma in b o a r d ( EB) is g iving t he a r ming
command to the alarm panel ONLY if the input “P” is on or flashing (all
zones of the control panel are closed or bypassed). If these condition
are not satisfied the arming command is ignored from .
Function not active as door opener.
(ON) Forced Arming: disabled
(OFF) Uscita CA: quick
(ON) Uscita CA: slow
((OFF) By pass as “sr”: arming in by pass mode (also with EB2) there
is first the activation of the by pass relay and then the total one (only as
STATUS)
(ON) By pass as “sr”: disabled
(OFF) reader Leds (RD) always switched ON
(ON) reader Leds (RD) switched ON only when approached the key
(OFF) PULSE Outputs
(ON) STAT US Outputs
(OFF) 1 arming
(ON) 2 arming
((OFF) door opener function: disabled
(ON) door opener function (only EB1) switching of CA output, as
soon as the key is recognised, for a time depending from setting of DIP1
and DIP6.
The readers connected to Cod2 can not carry out the arming in ON
Programming of Control Unit
Program zone L1 as Key ON and zone L11 as Not Used
Program zone L2 as Key HOME as zone L12 as Not Used
O.C.2 output must be programmed in mode “Cat. Arming - yes for ON HO AR - blk = yes “ Timing BISTABILE
O.C.1 output must be programmed in mode “ Cat Partition - RIBILANCIAMENTO” Timing BISTABILE
If the electronic key is used in IMPULSIVE mode, program Mode of key working as Impulsive
If the electronic key is used in AT STATE mode, program Mode of key working as At State
The above mentioned programming example is to be considered as an indication. Any input zone, with the exception of twin
zones (from L11 to L20) can become arming inputs.
Information about arming management
Control unit allows three different types of arming: ON, HOME and AREA. It is possible to arbitrarily associate any group of
zones to any kind of arming.
When control unit is armed in one of three possible modes, the zones associated to those modes will be active and will be
able to signal an alarm.
If control unit is armed by an external key, arming can be made in two different modes: impulsive mode or at state mode.
When it is armed by a keyboard, it always is in impulsive mode.
The fundamental difference between impulsive mode and at state mode, is the following:
•
impulsive mode, if the control unit has been armed by an external key, it can be disarmed by a keyboard and viceversa
•
at state mode, control unit cannot be disarmed by keyboard until an external key keeps it armed in at state mode.
Control unit gives a priority to arming modes where ON mode is the first one and HOME and AREA follow. This will cause the
latest higher-priority mode to be the final one
Example 1: control unit is armed in HOME mode by an external at state key. Later on, arming ON is given by
control unit. Control unit will go in ON. If it is then disarmed by keyboard, it will remain armed in HOME mode until
the external at state key disarms it completely.
Example 2: Control unit is armed in ON mode by an external at state key. Later on arming AREA is made by keyboard.
Control unit remains armed in ON mode. If it is then disarmed by at state key, it goes in AREA arming until completely
disarmed by keyboard.
Example 3: Control unit is armed by keyboard in any mode. Later on an impulsive key is used, in no matter mode.
Control unit is disarmed. The same would occur if the control unit was armed by an impulsive key and then
disarmed by a keyboard.
The device of external command must be at least IMQ 2nd level and its
de-codification board must be placed inside the control panel. The non –
respect of this indication makes the IMQ certification to decade.
- 13 -
General Characteristics of keys (mod. EB3)/ serial readers (mod. RS)
Up to 64 keys TOUCH can be acquired and they will be associated to various User Codes
Any key acquires a User profile and as a consequence all enabling options.
Thanks to recognition of the reader where operating, and via correct programming, it is possible to make some partial arming,
some activations of open collectors or emergency calls.
The reader can operate in two working modes, single or immediate.
The two modes make activations in different way: in single mode various possible activations are proposed to the user, in
immediate mode the arming/disarming is directly operated according to the enabling of the user-key (Touch) which is
approached to the reader.
Installation of serial key EB3
EB3 serial key must be connected to terminals of serial line
RS485 normally used for connection of keyboards or satellites.
•
They can be connected in parallel on the same serial
RS485 door up to 8 key (EB3)
•
4x0,5wires shielded cable use is recommended
•
total length of cable can be 600 meters and must shared
among all key, keyboards and extension devices possibly
connected.
Positive supplying output of serial RS485 door is protected by
fuse F1 2A. 250V
Board address
Board 1
Board 2
Board 3
Board 4
Board 5
Board 6
Board 7
Board 8
Dip
1
Off
On
Off
On
Off
On
Off
On
Dip
2
Off
Off
On
On
Off
Off
On
On
Dip
3
Off
Off
Off
Off
On
On
On
On
Dip
4
Off
Off
Off
Off
Off
Off
Off
Off
Local outputs of serial key
EB3 key has 5 active outputs giving a transistorized negative for connection to optional module (MR4).
Output n. 5 is dedicated to impulsive signalling of false key, other impulsive outputs are linked to the recognition of a User-Key.
They are active whether this has been done during programming (See User Profile and Key)
Working Mode of EB3 Electronic board
The key board has two behaviours which make EB3 extremely versatile and/or simple to use, responding to any need of the
user.
EB3 allows the management of arming/disarming of a single or more areas.
It can be used in the “open-door” mode making activation of some local outputs keeping in memory the users who have
operated on the reader (RD)
The device of external command must be at least IMQ 2nd level and its
de-codification board must be placed inside the control panel. The non –
respect of this indication makes the IMQ certification to decade.
- 14 -
Serial Readers RS
The RS readers are directly connected to the RS485 serial and allow to make all operations of arming/disarming of various
area sto which they are associated and/or the activation of open collector outputs.
TOWARDS
OTHER
READERS
ON
LED
Installation of the Readers
The serial reader (RS) must be connected to terminal boards of
the serial line RS485 normally used for connection of keypads
or satellites.
Can be connected, in parallel, on the same serial port RS485,
max 8 readers (Mod. RS)
Shielded cables at 4 wires 0,5 mm each are suggested
The total length of the connection cable can be 600 meters and
must be shared among all boards connected
The positive supplying output of the serial port RS485 is
protected by fuse F1 2A. 250 V.
Technical Characteristics
Accensioni max.
3
Accensione Condiz ionata
si
Inseritori numero max.
8
Inseritori metri max.
lunghezza della seriale
Chiavi max.
64 chiavi
Tensione nominale
12 V
Assorbimento min.
25 mA
Assorbimento max.
30 mA
Attivaz ione OC
A stato o Impulsivo
Addressing
Condiz ioni ambientali
+5°C / +55°C
Whenever the installation needed more points of activation,
the readers installed must be addressed using the 5 ways dip-switch, placed on the board.
The numbering of the readers must be progressive.
Indirizzo
Dip
Dip
Dip
Dip
Dip
Inseritore
1
2
3
4
5
Inseritore 1
Off
Off
Off
Off
Off
Inseritore 2
Off
On
Off
Off
Off
Inseritore 3
Off
Off
On
Off
Off
Inseritore 4
Off
On
On
Off
Off
Inseritore 5
Off
Off
Off
On
Off
Inseritore 6
Off
On
Off
On
Off
Inseritore 7
Off
Off
On
On
Off
Inseritore 8
Off
On
On
On
Off
In order to address the readers, place the dip-switches
according to the chart
Please consider that there cannot be more readers with
the same address, otherwise they will cease working and
the control panel will activate a Tamper alarm. In this case,
in order to restart working again, it is necessary to:
a)
give correct addresses to readers
General Characteristics
TOUCH is the product of recent technological evolution of electronic key. Thanks to this technology, TOUCH responds to the
requirements of high security , offering the user wide performances and great comfort
The keys Touch must be acquired by the mother board before working
Follow the indication in order to acquire the code by all keys assumed to do it
Protect the external readers against any possible attempt of tampering
The key must be placed in a position parallel to the leds
Never position the readers side by side but keep them separated by a blind reader
Proximity key with recognition and memory of false key, with visualisation of the inputs status and control panel on the reader
with possibility of automatic partialization of the system
The key does not need any battery in order to work
By use of the same key, it is possible to command more systems even with different functions (home, office, open a door, a
gate, arm and disarm one or more devices), that’s to say to operate in all those situations where the key has been acquired.
Warning
Installation: the device must be installed only by qualified personnel
L’organo di comando esterno deve essere almeno di II livello IMQ e la relativa
scheda di decodifica deve essere collocata all’interno della centrale.
Il non rispetto di questa segnalazione fa decadere le prestazioni IMQ.
- 15 -
Working of key board EB3/serial readers RS
Acquisition of the keys with EB3 installed
The acquisition of the keys TOUCH must be made directly approaching the key to the reader, after enabling the necessary step
(please refer to control panel programming at paragrapho ACCESS Touch on EB3 Key Acquisition)
Acquisition of keys with serial reader RS installed
The acquisition of the keys Touch can be made directly approchaing the key to the reader, after enabling the necessary step or
by using the keypadsA600Plus (please refer to control panel programming at paragraph ACCESS Tch A600P/RS Keys Acquisition.
Cancellation of Keys
In order to cancel the keys Touch, follow what described in the control panel programming at paragraph ACCESS Touch on EB3
Tch A600P/RS Key Cancellation)
Viasualization of arming/disarming commands
(A)
(B)
(C)
(D)
Green Led
Red Led 1°
Red Led 2°
Red Led 3°
(A)
(B )
(B )
(C )
(C )
(D )
Area/s = Off
Area/s = Total armi ng (ON)
At least one parti ti on of those associ ated to the reader i s
di sarmed or not all parti ti ons associ ated to the reader are armed
i n the same mode.
Area/s = parti al armi ng 1 (HOME)
Area/s = Off wi th memory alarm
Area/s = parti al armi ng 2 (AREA)
Green
L ed
led (1), (2), (3) Off
led (1), (2), (3) on
led (1), (2), (3) - - - bli nki ng
led (1) On
led (1) slow bli nki ng
led (2) On
Balanced zones: on
Unbalanced zones: off
At least one zone excluded: slow bli nki ng
General status of the system
It shows the occurred recogni ti on of the key, or the condi ti on i n
Green
whi ch i t i s possi ble to remove the key wi thout varyi ng the status of
L ed
the outputs on board
Qui ck bli nki ng
Mode of single command
In this mode, the peripheral can be associated to one or more areas and various possibilities of activation are proposed to the user.
The operations allowed will only be those enabled for the Key-User.
Note only EB3: if the board is associated to more than one area , the Key User will be enabled to operate only if associated to a single area.
If the peripheral is associated to more than one area, the LED visualization on readers is normally deactivated; the visualization of the status
of one area after being recognized by the Key-User will be enabled; if on the contrary the key-board is associated to a single area; the LED
can be programmed either as normally on or deactivated.
Visualizationof the system status
If Leds are normally enabled
All Leds always visualize the present status of the area associated to the reader; if the reader is associated to more than one area, the
visualization of the Leds is normally deactivated; the visualization is activated when a Touch key is approached to the reader. (see below)
If Leds are normally not enabled
To enable visualization
Approach the key until the green Led blinks quickly
Remove soon the key in order to have the visualization of the status.
Arming /Disarming
In order
1.
Wait for
2.
top operate an arming /disarming approach the Touch key to the predisposition indicated by AVS logo
approach the key
visualization of the desired mode, which will change by cycle ;
(A) —> (B) —> (C) —> (D) —> (A)
Removing the key, the command of arming/disarming will be given
Immediate mode of command
In this mode the control panel immediately operated the functions associated to the Key-User without waiting for removing of Touch. As far
as this regards the arming, the Key User will always make the priority one for which he is enabled or the disarming.
It is suggested to associate the peripheral to one area only and to leave the Led visualization always active.
Note only EB3: if the key-board is associated to more than one area, the Key-User will be enabled to operate only if associated to one single
area. If the peripheral is associated to more than one area, the LED visualization on readers is normally deactivated
Visualizationof the system status
If Led are normally enabled
All Led always visualize the present status of the area associated to the reader; if the reader is associated to more than one area the Led
visualization is normally deactivated
If Led are normally not enabled
The system status will never be visualized.
Arming/Disarming
In order to operate an arming/disarming, approach the key Touch to the predisposition marked by the AVS logo and a status change of control
panel as well as possible activation of OC outputs if associated to Key-User will immediately activate
- 16 -
LOGICOM - Technical characteristics
External connection:
•
for telephone line
Tel. profiles:
Protocols:
•
•
•
•
•
•
•
•
n° 8 profiles of 4 telephone numbers
FAST FORMAT
SEIA, SIA for standard receivers
SIA_HAYES for XM40 Hayes modem or enabled AVS
VOCAL (mod.EUROSINT )
CONTACT-ID
customizable presentation messagge
file of pre-recorded messages, that allows to have an automatic compo sition of
more than 2000 different messages
activable only using the optional mod.EUROSINT88
12 V
+ 5 °C / + 40 °C
in quiet: 20 mA
in transmission: 58 mA
in quiet: 20 mA
in transmission: 60 mA
200 x 120 x 60 mm
Min. PP.TT: n° IT/96/TF/080 according to NET 4
Vocal Synthesis: (mod.EUROSINT 88):
Remote Telephonic Control:
Supply voltage:
Enviroment conditions:
Current consumption:
Current consumption EUROSINT 88 :
Dimension:
Approvals:
•
•
•
•
•
•
•
•
•
Connection to the control panel
Installation of dialler
a.
b.
c.
d.
e.
Remove power
Insert the dedicated plastic spacer into the right holes on the plate.
Insert the board, respecting the fixing holes, and the connection.
Screw the dialler board on plastic and metal spacers.
Give power to the control panel.
Connection of the telephonic line
For correct functionning of the in board protection, it is necessary to connect the earthing in the special terminal board.
The effectiveness of this protection depends on the generality of the earth connection.
AB : connection of the input telephone line, before every type of telephonic equipment.
A’ B’ : connection to other telephonic equipment.
- 17 -
GSM Plus - Caratteristiche tecniche
External connection:
•
Canale GSM
Tel. profiles:
Protocols:
•
•
•
•
•
n° 8 profiles of 4 telephone numbers
FAST FORMAT con canali assegnabili
VOCALE (mod.EUROSINT 88)
SIA
CONTACT-ID
Vocal Synthesis: (mod.EUROSINT 88):
•
•
Remote Telephonic Control:
•
customizable presentation messagge
file of pre-recorded messages, that allows to have an automatic compo sition of
more than 2000 different messages
activable only using the optional mod.EUROSINT88
Supply voltage:
Enviroment conditions:
Current consumption:
•
•
•
•
•
•
•
•
Current consumption EUROSINT 88 :
Dimension:
12 V
+ 5 °C / + 40 °C
iin quiet: 50 mA
in transmission: 400mA
in quiet: 20 mA
in transmission: 60 mA
200 x 120 x 60 mm
Installation
How to proceed
a. both mains and battery supplying have to be taken off
b. insert proper plastic spacers into the holes on the right of the fixing base of the control unit board
c. insert the board of the GSM dialler by connecting the two connectors, respecting the fixing holes
d. screw the dialler board on the plastic spacers and metal turrets
e. break the predisposition on the control unit housing
f. insert the antenna and fix the nut firmly
g. make the antenna cable pass through the hole on the board and insert it on the predispositions as shown on the
picture
- 18 -
LOGICOM + GSM Plus
If both telephone line and GSM net are needed, it is necessary to connect both LOGICOM and GSM PLUS boards as shown
in the picture. The calls are managed according to the type of interface chosen during programming.
Ingresso connettore antenna
In this configuration it is necessary to eliminate the tamper predisposition placed in the centre of the board and use the
predisposition placed on the top of the board, shaping it in the right way in order to install the tamper pushbutton.
SIM Card Insertion/Antenna Connector Entry
To insert Sim Card:
1. insert Sim Card completely
Antenna connector
entry
To take off Sim Card:
press on Sim Card and then release it
C
Sim Card
entry
Before inserting and removing the SIM Card, i twill be
necessary to completely un-supply the control panel
De-activate the pin code on Sim boards
De-activate all call-transfer
De-activate automatic answering machine
Cancel all SMS on SIM
Low Sim Card credit occurs when reaching 8
euros threshold
Credit Control
This control is made automatically, no matter the use of GSM.
It is also made when GSM makes operations reducing the credit.
Reaching the threshold of 8 euros the string LOW CREDIT is visualized on keyboard and if the telephone calls for
GSM events
1 have been enabled in “Events Association” of telephone dialler, they will be made
Prof. : nnnnnnnn
Setup of Sim Card Expiry
This operation is necessary anytime a SIM recharge is made or at first activation, in order to have the panel
communicating the Sim Card Expiry.
It is recommended to set up the warning in advance compared to the expiry, in order to avoid a possible block by
the provider.
It is possible to visualize the remaining credit, the GSM signal level and to vary the SIM Card expiry, following the
procedure described in the User’s manual.
- 19 -
Vocal synthesis board
Protocols:
Messages:
•
•
•
RTC Remote Telephone Control
Tension:
Working Temperature:
Consumption:
•
•
•
•
•
•
Size of board :
VOCAL (mod.EUROSINT88)
Message of presentation personalized
A li b r a r y o f p r e - r e c o r d e d m e s s a g e s a llo ws a ut o m a t i c a nd p e r s o na li ze d
composition of alarm messages and different technical events
Programmable activation for any single user profile
tNominal tension: : 12 V
+ 5 °C / + 40 °C
in quiet: 20 mA
in transmission: 60 mA
85 x 60 mm
It is an optional board.
EUROSINT88 model allows:
1. to send 1 personalized message, and then other pre-recorded event messages
automatically formed by control panel.
2. to activate the RTC (Remote Telephonic Control) function; this function allows to execute,
using a DTMF phone on telephone line or a mobile, checking of control panel status and
other remote control (operations like: arm / disarm / bypass ect.).
On the board there is the connection to record and listen to the vocal message.
Circuit connection
1. Remove power
2. Connect EUROSINT88 on control panel electronic board
3. Give the power.
Record and check the message
to record and listen to the message use a normal touch tonephone connected to the proper plug on EUROSINT.
To record and Listen to the message, connect the board EUROSINT88 and LOGICOM or GSM Plus to the control panel board and
set in installation programming : Dialler YES
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Move the jumper
S1 in position (closed)
Connect the phone using the input plug on EUROSINT88
Pick up the hand set
Press and release together REC (PB2) and PLAY (PB1) to start recording
Speak with clear voice on the microphone; check on the display the elapsed time
NOTE: If the message is shorter than 10”, it is suggested to press the
REC push-button (PB2) to stop the recording.
To playback message, press the PLAY push-button (PB1) to start
If the recording is wrong, repeat the procedure starting from the step
N.3
At the end, disconnect the phone from the proper plug on EUROSINT88
Move the jumper (S1) to save prevent unwanted erasing of the
messages.
S1 in position (open)
- 20 -
SINT88 characteristics
SINT88 is an optional board of vocal synthesis which must be connected to the control panel board
via 4 connectors (Can be used from version 6.0 and following ones)
The SINT88 model allows:
1.
to send 1 personalized message, followed by pre-recorded messages automatically
created by the control panel and showing the event to communicate to the programmed
numbers;
2.
DON’T ALLOWS to activate the RTC function (Remote Telephone Control); this function
allows to have access to a commuted telephone line or GSM by use of a DTMF device as
well as to the interrogation of the control panel status and remote management of the
panel itself; ONLY WITH EUROSINT88
The communication will activate when the events associated to the telephone number having the
protocol programmed as VOCAL, will occur.
Insertion of the circuit
1.
Totally eliminate supplying to control panel
2.
Insert in correct way the vocal synthesis board on the control panel, adjusting the 4 male connectors placed on
the lower side of the circuit with the female connectors placed on the circuit of the control panel; press softly until
complete insertion.
The control panel will communicate vocally all events associated to the telephone number in the menu “events association”
and the alarms of the single zones associated to the telephone number.
Recording and control of SINT88 – EUROSINT88 messages
In order to record the messages and to control them, use a normal BCA electronic telephone device
at low consumption, connected to the plug placed on the vocal synthesis circuit; check that the
device is in DTMF mode (MF)
1.
2.
3.
give again supplying to the control panel
connect the telephone device using the plug placed on the synthesis board
dial the installer code and start recording from the menu (by default 000000)
For recording of vocal messages it is necessary to use the guide menu which is inside the
programming by installer code.
Play Rec mess.
ENT
éê
Mess.voc. # 154
(max.178)
Ascolto
Registr.
ENT
MEM
Ascolto / Registr.
****=======
Play Rec messaggi:
Messaggio Vocale n°??: it is necessary to select the message to record.. By use of
the arrows (é)/(ê) select the message to record; press ENT to confirm
Playback ENT: press ENT to listen to the message
Record MEM: press MEM to record
Stop Record ESC: Press ESC to break the recording
PS only the message 154 has 10 seconds recording, the others have max
from 0,8 to 2 seconds
The vocal message 154 corresponds to the presentation message
Further to the recording of the presentation message, it is possible to record other words overwriting some vocal words.
This possibility is worth with both use of the vocal board SINT88 and EUROSINT88
On the page “phonetics chart” there is an indication of the phonetics which can be overwritten.
- 21 -
Vocal messages
ADV 88 gives the possibility of sending specific vocal messages according to the events. These messages can be either
technical messages or alarm messages and/or inputs reset messages.
Technical messages: they re related to situations such as supplying problem, absence of telephone line or other. They are
automatically composed using the vocabulary of pre-recorded words shown in the Phonetics Chart; the introducing message
MESSAGGIO 1 (Phonetics Code 154) is ususally associated and placed before these messages. The introducing message
is used to record the address of the building where ADV 88 is installed and if the areas are activated, the message concerning
the belonging areas of the event.
These messages (Message 1 and Area) can be activated or not at the transmission, for any single profile of telephone
numbers.
Automatic Communication Zones
Alarm/Zone Reset Messages: they concern the opening or closing of the inputs
The communication of opening/closing of the inputs are usually automatically composed by ADVANCE 88 according to the
line set during SIA coding (e.g. Burglar line, gas line etc.) and to the zone number (1-88) and it is usually associated and
placed before the introducing message MESSAGGIO 1 (Phonetics code 154), and if the areas are activated, the message
concerning the belonging area of the event.
Personal Communication Zones
Should it be necessary to force the communication of ADVANCE 88, creating a different message, it is possible to use the
library of pre-recorded words and add the code of the word during steps “Vocal word 1-2-3-4” as shown in the chart “Phonetics
Zone parameter
ENT
éê
Says alarm/rest.
YES
Says zone code
YES
Says zone speech
YES
Says zone number
YES
Vocal word 1
0
(max. 255)
Vocal word
2
0
(max. 255)
Vocal word
3
0
(max. 255)
Vocal word
4
0
(max. 255)
Chart” inside telephone menu.
It is possible to personalize the communication for any single input, choosing whether the control unit can communicate or
not the “automatic words” and have other 4 extra phonetics available(“Vocal word 1-2-3-4”)
- 22 -
Phonetics Chart
A factory specific pre-determined word corresponds to the Phonetics Code, which can be used to personalize the vocal
messages of the control unit.
P h o n etics
C ode
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
83
63
32
69
136
47
44
59
84
158
112
70
142
95
125
103
71
Vocal
C ommunication
ONE
TWO
THREE
FOUR
FIVE
SIX
SEVEN
EIGHT
NINE
TEN
E LE V E N
TWELVE
THIRTEEN
FOURTEEN
FIFTEEN
SIXTEEN
SEVENTEEN
EIGHTEEN
NINETEEN
TWENTY
THIRTY
FORTY
FORTYONE
FIFTY
FIFTYONE
SIXTY
SEVENTY
EIGHTY
ZERO
AC C OUNTANC Y
AC TIVE
ALARM
ALLOWED
AND
AREA
ARMED
ARMING
ASSEMBLY
ASSEMB LY
ATTIC
AUTOTEST
BAC K
BARRIER
BASEMENT
BATHROOM
BATTERY
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
P h o n etics
C ode
177
73
35
96
42
65
81
113
40
89
169
166
130
152
97
114
100
48
60
135
91
52
134
168
77
56
58
153
54
55
53
104
79
106
109
101
110
145
127
74
139
118
178
46
117
151
57
P h o n etics
C ode
108
31
67
38
147
99
170
124
90
72
50
92
75
150
51
98
133
62
149
107
128
102
45
66
61
160
41
30
122
115
64
172
49
143
85
82
167
123
157
93
34
144
148
86
39
132
68
Vocal
C ommunication
B OILER
BURGLAR
BYPASSING
C E LLA R
C OD E
C OMMAND
C OMMERC IAL
C OMMON
C OMMUNIC ATION
C OMPLETED
C ON D ITION ER
C ON TAC T
C ORRID OR
C RED IT
D AY
D EGREES
D EPARTMENT
D ISARMED
D ISARMING
D OOR
D OWNLOAD ING
D URESS
EAST
ELEC TR IC
EMERGENC Y
ENTER
EXC LUD ED
EXHAUSTED
FALSE
FALSE
FIRE
FIRST
FLOOD ING
FLOOR
FLOOR
FRONT
GARAGE
GARD EN
GARRET
GAS
GATE
GROUND
H EATIN G
HOME
HOURS
HUMID ITY
ID ENTIFIED
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Vocal
C ommunication
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
INPUT
INTERFERENC E
KEY
KEYPAD
KITC HEN
LAND ING
LE V E L
LIVING ROOM
LOAD ING
LOW
MAINS
MANAGEMENT
MED IC AL
MINUS
MISSING
NIGHT
NORTH
NOT
OFF
OFFIC E
OFFIC E
OLD
ON
OPEN
OUTPUT
PAIN TIN G
PANEL
PANIC
PERC ENT
PERIMETER
PERIPHERIC AL
POWER
POWER SUPPLY
PRESSURE
PROD UC T
PROD UC TION
PU MP
RANGE
RAW_MATERIAL
REC EPTION
RESTORE
ROOF
ROOM
S A LE S
SATELLITE
SEC OND
SEC TION
P h o n etics
C ode
173
146
137
120
87
105
94
78
116
33
129
80
76
138
88
176
131
111
121
37
43
174
161
119
126
140
141
36
154
Vocal
C ommunication
SEN SOR
SID E
SINGLE_ROOM
SITTING_ROOM
SOLD ERING
SOUTH
SPARE_PARTS
SPRINKLER
STREET LAMP
TAMPER
TAVERN
TEC HNIC AL
TEMPERATURE
TERRAC E
TESTING
TH ER MOSTAT
THIRD
THIRTYONE
TWENTYONE
UNBYPASSING
USER
VEN TILATION
VOLU METR IC
WALL
WAREHOUSE
WEST
WIND OW
ZONE
A D VA N C E88
A D VA N C E88
It will be possible to re-write and personalize the words from phonetics code 154 and following .
Recording a word in one of those locations, it is possible to integrate the phonetics available; previous words will be deleted
and not available any longer.
Reminder of the phonetics which can be personalized
P h o n etic s
code
154
155
156
157
158
159
160
Vo c al
C o m m u n i c at i o n
d o n ' t u se
d o n ' t u se
d o n ' t u se
•
•
•
•
•
P h o n etic s
code
161
162
163
164
165
166
167
Vo c al
C o m m u n i c at i o n
d o n ' t u se
d o n ' t u se
d o n ' t u se
d o n ' t u se
•
•
•
•
•
P h o n etic s
code
168
169
170
171
172
173
174
- 23 -
Vo c al
C o m m u n i c at i o n
d o n ' t u se
d o n ' t u se
•
•
•
•
•
P h o n etic s
code
175
176
177
178
Vo c al
C o m m u n i c at i o n
RTC function (Remote Telephone Check )
RTC function allows to make some operations with the control panel using a touch tone telephone (DTMF) connected to a
telephone line or using a mobile phone.
• Must be the optional connected board EUROSINT88;
User activation in RTC
1.
2.
Call the control panel sectors (partitions) using a touch tone phone.
After the programmed Num.Rings Answer for POTS call, or at the first ring in GSM, the control panel answers
automatically: “enter yuor code” or, only on GSM net, "GIVE COMMAND" if the procedure of recognition of the incoming
number is enabled
3. Digit slowly the RTC enabled User Code;
•
If an answering machine is connected on the telephone line, it is possible to bypass it.
a. Call the control panel and, after first ring hang up immediately.
b. Call again the installation after 10 to 20 seconds; the control panel will answer after 1 ring.
c. Digit slowly the User Code enabled to RTC
4. If the User Code is recognized, the control panel will communicate: Recognized User.
5. Now it is possible to activate some functions;
USER RTC with recognition of incoming number
This function allows the calling person to communicate directly with no need of dialling the User Code; this function is active
for calls
on GSM net only, so the GSM Plus is necessary. It only occurs if, during programming, the telephone number operating the
RTC has
been associated to an User enabled to RTC and to "Automatic RTC Validation"
USER DTMF COMMANDS
The command is activated pressing the number on the phone keypad.
ATTENTION: You have only 2 / 3 minutes to execute these operation after the connection in aborted by the
panel.
• [0] OFF ZONE: press to activate the possibility to bypass the zone.
• [1]: press to have the possibility to choise the sector (partition)
• [2] MEM listening to history of events memory
To run along the vocal memory [2] get out [5] up [8] repeat [0] down
• [3] OFF TEL: press to stop the telephonic communication.
• [5] OFF: press to disarm the control panel.
• [6] O.C.: press to activate an Open Collector Output. It is possible to manage only the Open
collectors programmed as O.C. User. Example: to activate the O.C. n° 2;press the push-button [6] and
[2] and than [#]
• [7] TEST: press to have the information about the control panel status.
• [9] ON: press to arm in ON the control panel.
• [8] Partial Arming: press to arm in Partial mode the control panel.
• [#] ENTER: press to confirm the input data
INSTALLER RTC ACTIVATION
1.
2.
3.
4.
See the point 1 for the User RTC
See the point 2 for the User RTC
Digit slowly the Installer Code
Now it is possible to activate some functions; remember to wait the bitonal signal after evey command .
INSTALLER DTMF COMMANDS
• [2] Press to activate the Event Memory Dump on n.8 telephone number.
This function is available from Sw version 1.98
NOTE: the event memory dump can be also in VOCAL protocol
• [4] Press to change the Date and hours in RTC.
After the push-button [4], digit in sequence the Date and hours digits. After every digit, the control panel makes a
beep.
For example, to set the date 3 April 02, hours 9:50, digit:
0 3 0 4 9 8 0 9 5 0, a bitonal signal will communicate the system updating.
- 24 -
Management of SMS on the way out
ADVANCE 88 has the possibility of sending specific messages according to the events generated..
These messages can be both technical or alarm messages and/or of inputs restore.
Technical Messages: they are related to situations such as supplying anomalies, as battery and are automatically dialled
making use of a library of per-recorded messages.
Zone messages: are related to signalling of zone inputs for both alarm communication, restore and exclusion.
Zone parameter
ENT
éê
Says alarm/rest.
YES
Says zone code
YES
Says zone speech
Says zone number
YES
YES
Send. SMS strip
YES
The zone SMS are dialled by the sequence of 4 standard words to which a zone strip can be added.
Management of incoming SMS
It is possible to ask the control panel the execution of commands from remote way, using sms appropriately codified.
The same operations as for the vocal RTC connection can be required.
The incoming sms are executed onlyif:
the calling telephone number is associated to a user
the associated user is enabled to RTC with automatic validation according to telephone number
their syntax is correct
require actions to which the user is enabled
List of the Commands
Type
OC activation
OC deactivation
Control panel arming
Control panel
disarming
Zone exclusion
Zone re-inclusion
Status request
Operation
confirmation
Syntax
Example
#att number_oc#
#att 13#
#disatt number_oc#
#disatt 13#
#acc [on|ho|ar] sector#
#acc ho 2#
#sp sector#
# sp 2 #
#escl number_zona#
# e scl 3 6 #
#reincl number_zona#
#reincl 36#
#stato#
#stato#
# co #
More commands can be put in the end of the same message,
provided that:
- the total length is not over 30 characters
- the commands are separated by #
- any command is preceded and followed by #
The exceeding space will be removed
Example of correct sequence:
#escl 12#escl 15#acc on 2#stato#
Example of WRONG sequence
#escl 12#acc on 2#stato
escl 12 acc on 2#stato#
Only the command #co# and #stato# provides the sending of an answer message, the others do not generate a reply (not
even in case of mistake)
The command #co# sends the confirmation of the operations in one or more sms; it can be included in any position in the
sms.
The command #stato# sends the situation concerning the following sections, in one or more sms:
-
arming condition of the control panel
balance condition of the zones (disarmed control panel) or alarm memory (armed control panel)
exclusion condition of the zones
possible lack of mains and/or battery
condition of the users o.c. associated to the profile of the user sending the request message
condition of SIM CARD prepaid credit
It can be included several times in the request message and it will send the system status at different times:
Ex. #stato#acc on 3#stato#
The sections “zones” and “exclusions” contain the number list of the related zones (sequence of numbers separated by
space).
One or more sms are sent; any section is contained in one single sms, but a sms can contain more sections.
Should the single section be bigger the size provided, the message will be cut and finished with suspension dots.
Example: #opened zone 1 2 34 24 25 26 27 28 29 30 31 32 33 45 46 47 …#
- 25 -
SOME NOTES CONCERNING SECTORS (PARTITIONS) AND ARMING MODES
Logitel 8 Plus ADVANCE includes the sectors (partitions) management.
With this control panel it is possible to create up to four (4) parted sectors (partitions) and one (1) common sector (partition) where
the zones, common to all sectors (partitions), will be included.
The common zones will be armed after the arming of all other sectors (partitions).
During the programming, we must set how many parted sectors (partitions) are existing in the installation.
The sectors (partitions) are usefull when a single control panel is shared for different installation, for normal application this
function is not used, and all zones will be associated to sector (partition) n°1.
Arming
Every sector (partition) could be armed in different arming modes. Example: sector (partition) n°1 could be armed in ON, and other
sectors (partitions) in HOME or AREA.
The common sector (partition), when all sectors (partitions) are armed, will be automatically armed in the lowest armed sector
(partition).
The control unit allows three arming modes: ON, HOME and AREA. To each type of arming it is possible the association of the
zones .
The arming of the unit from an external key can be of two different modes: PULSE or STABLE .
The arming from the unit’ keypad is always pulse.
The fundamental difference between the pulse and the stable modes are that in the first, if the control unit is armed from an
external key, the unit can be disarmed from the keypad and vice versa; in the second mode, the control unit armed from an external
key cannot be disarmed from the keypad and vice versa.
The control unit establishes a hierarchical order of the arming in which the ON mode is at the top level, followed from HOME and
AREA. This determines that if firstly there is an external arming and later take over an other of taller level, the control change to the
higher arming level.
Example 1: the control panel is armed in HOME mode from an external key (STABLE). Later is armed from keypad in ON. The
control unit is now armed in ON.
If then it is disarmed from the keypad, it is still pending the first external arming HOME.
Example 2: the control panel is armed in ON mode from an external key (STABLE). Later is armed from keypad in AREA. The
control unit remain armed in ON.
If then it is disarmed from the external command, it is still pending the second arming AREA.
Example 3: the control panel is armed in one mode from the keypad. Later can be armed/disarmed from an external command
if programmed in PULSE status.
Every zone must be associated to a sector (partition).
If one or more sectors (partitions) generate an alarm, the alarm outputs will active. For stopping the signalling it is enought to
disarm the sector (partition) where the zone is associated.
Every keypad must be associated to one or more sector (partition), this allows to keypads to visualise the events of its sectors
(partitions). The technical events are showed on every keypad.
The keypads associated to all sectors visualise the events of all sectors (partitions).
The common zones are visualised only when the last user will arm the last sector (partition), only this user, or an user associates
to every sector (partition), can by-pass and un by-pass the common zone.
The message “0 active zones” on keypad, exiting from installer menu, means that common zones are not associated to any
arming modality. To clear this message it is enough to digit the user code.
The message “0 active zone” on keypad, after an arming sector (partition), means that there are no active zones in that arming
modality.
User code and Keypads
The User 1 is associated to sectors 1,2,3,4 and managed as “User Master ->NO”
The User 2 and 3 are managed as “User Master ->NO”
User code/partition
USER 1 (partition 1,2,3,4)
USER 2 (partition 1)
USER 3 (partition 2)
Keypad (partition 1,2,3,4)
choise the partition
visualized partition 1
visualized partition 2
Keypad (partition 1)
visualized partition 1
visualizza settore 1
no access
Keypad (partition 2)
visualized partition 2
no access
visualized partition 2
The User 1 is associated to sectors 1,2,3,4 and managed as “User Master ->SI”
User code/partition
Keypad (partition 1,2,3,4)
Keypad (partition 1)
USER 1 (partition 1,2,3,4)
choise the partition
choise the partition
USER 2 (partition 1)
visualized partition 1
visualizza settore 1
USER 3 (partition 2)
visualized partition 2
no access
Keypad (partition 2)
choise the partition
no access
visualized partition 2
If an User digits the code in a wrong keypad, the message “Wrong Code” will be showed.
- 26 -
15 GIU 02
00 : 00 : 15
PROGRAMMING
ââââââ
00 : 00 : 15
Dial Installation Code followed by ENT
(default 000000)
Advance 88
avs electronics
Lingua/Language
Press CLR...
If code is recognized, the writing “Advance88” will appear
Press (ENT) to confirm
Lingua/Language
Italiano
TAKE CARE !!! At first installation or after procedure of EEPROM RESET, system might
require to convert control unit into the local language
Press (CLR) to choose language
Press (ENT) to confirm
INSTALLATION
Installation
ENT
éê
LCD Keypads
1
(max. 8)
Zones Expansions
0
(max. 4)
EB3
Easylink
Dialler
NO
NO
NO
Panel Line bal
balanced
Red. event mem.
NO
LCD Keypads: programming of the number of connected keypads .
Zone Expansion: programming of the number of connected satellites.
EB3: programming “YES” if the serial proximity key is connected.
Easylink: programming if the Easylink is connected.
Dialler: programming “YES” if the telephone dialler LOGICOM is installed.
Management of control panel zones
It is possible to vary the basic setting of the system for the zones connected in
control panel
Balanced: it sets the inputs in control panel to be balanced
Double zones: it enables the management of the double zones on control
panel
Not balanced: its sets the inputs on control panel as normally closed (not
balanced)
Red. event mem: insert “YES” if you want the reduced event memory.
Second zone enable - Advance menù enable
Setting “YES” the advanced programming of control unit is activated. The
programming of the zone profiles.
2th zone enable
NO
Events which are not kept in memory setting “SI” in “Reduced Events Memory”
USER’S OPERATIONS
Exit from menu
Change date and hour
Fire reset
User test
Arming on
Arming ho
Arming ar
Disarming on
Disarming ho
Disarming ar
User’s identification
USER’S OPERATIONS OC
Automatic
Automatic
Automatic
Automatic
operation
operation
operation
operation
of arming
of disarming
oc disarmed
oc armed
to following
page
- 27 -
from previous
page
Sectors
ENT
éê
SECTORS
Active sectors
ENT
éê
Sectors: 01234
nsnnn
Associate zones
ENT
éê
Associate zon
1111111111
Active Sectors
An active sector is intended as the possibility to manage up to
four systems completely separate.
The zones common to the active sectors will have to be part of
sector 0 which will have to be armed
Press on (CLR) to vary
Press on (ESC) or (MEM) to choose
Press on (CLR) to vary
Press on (ENT) to confirm
1
Associate zon 11
1111111111
Associate zon 25
111111111111111
Associa Zone 41
111111111111111
Zones association
By default, all zones are associated to sector 1, in this way the
system will soon be able to manage a sole system
0
1
2
3
4
=
=
=
=
=
common sector (all active sectors are associated)
sector one
sector two
sector three
sector four
Associate zon
0011223344
1
Associa Zone 57
111111111111111
Associate zon 73
111111111111111
Keypads assoc.
ENT
éê
Keypad Num. #
0
(max. 8)
Sectors:1234
snnn
Keyboards association
It determines the sector associated to the
keyboard:
S only on 1: associated to Sector One
S only on 2: associated to Sector Two
S only on 3: associated to Sector Three
S only on 4: associated to Sector Four
Note: any keyboard can be associated to
one or more sectors.
to following
page
- 28 -
from previous
page
Zones
ENT
éê
ZONES
Zone type
ENT
éê
ÊPress (CLR) to vary
Move the flashing slider by using the arrows (è) and
(ç) in correspondence of the zone which has to be
pogrammed according to the chosen mode
ÊIn order to chose the programming mode, use the
arrows
(é) and (ê), the type of zone is visualized on the top of
the display
ÊPress (CLR) to vary
ÊPress (ENT) per confirm and (ESC) to go back
Istant 1
iiiiiiiiii
Non used
---------Non used
----
11
21
Non used 25..73
----------------
ÊTo move to another group of zones, if any, use the
Function Button (5) “Fast Select”
During programming of the zones, button (5) helps changing
entire groups of zones in the selection from YES to NO or vice
to page
“Arming”
To following
page
[-] Not used: the zone is excluded; the input must be short-circuited with a resistor (4K7).
[i] Instant: line that provokes an immediate alarm when opened (with control panel armed).
[h] 24 hours: it is a zone 24 hours a day active; it is independently from the arming/disarming status of the control panel. Can
be by passed using the OFF ZONE function. The alarm stops after entering a USER CODE.
[1] Delay T1 / [2] Delay 2 / [3] Delay 3: is a delayed zone following exit and entry timer [1- 2 -3].
The entry and exit time can be signalled from the intermittent sound of the buzzer of the keypad. The sound of the entry time has
a different frequency. The sound of the buzzer of these times can be programmed independently for each keypad.
[c] Conditional: direct zone that comes automatically by passed during the execution of the exit and entry time (of a delayed
zone); in the case there are more delayed zones, the reference is the longer time. When the control panel is armed and there
is no exit/entry time in execution, the opening of this zone is giving immediate alarm.
[a] Inst. perm esc.: instant zone that comes automatically by passed if results open at the arming of the control unit; it stays by
passed up to the disarming.
[b] Inst. Temp. Excl. (instantaneous zone with temporary exclusion) it is automatically excluded if not balanced at arming of
the control unit; it is automatically included at its balancing.
[4] Delay 1 with permanent exclusion – 5) T2 Perm. Excl. - 6) T3 Tempor. Excl.: they are temporized zones with permanent
exclusion. They are automatically excluded if they are not balanced at the end of the output time (1-2-3); they remain excluded
until disarming of control unit.
[7] Delay Timing1 with temporany esclusion / [8] T2 Temp.escl. / [9] T3 Temp.escl.: delayed zone that comes automatically
by passed if, at the ending of the exit time 1, results open; it is automatically un-bypassed if comes closed. Now if opened
again is following the secondary entry time 1.
[j] 24 hour Delay 1 / k) 24 hour Delay 2 / l) 24 hour Delay 3: zone indipendent from the arming of the control unit, it’s active with
both armed or disarmed control unit. When unbalanced, the re-entry-time is available(1-2-3), signalled by an intermitting highfrequency sound; once this last time is over, an alarm will be activated unless the user code has been dialled in the meanwhile;
it can be excluded form the “OFF ZONE” function
[X] 24 hour with prealarm 4/ [W] 24H prealm. 3 / [V] 24H prealm. 2/ [U] 24H prealm. 1: zone indipendent from the arming of
the control unit, it’s active with both armed o disarmed control unit. Zone causing an alarm when unbalanced, at the end of the
pre-alarm time (1-2-3-4). If the zone is balanced during this time, it breaks off and resets the pre-alarm counting. During prealarm time the zone can be activated: buzzer, (door-chime), pre-alarm O.C., zone state O.C., alarm messages on keypad,
memory of pre-alarm events.
[x] Istant with prealarm 4/ [w] Istant pre. 3 / [v] Istant pre. 2 / u] Istant pre. 1: zone causing an alarm when unbalanced at
armed control unit, at the end of prealarm time (1-2-3-4). If during this time the zone is balanced, it breaks off and resets the
pre-alarm counting. During pre-alarm time the zone can be activated: buzzer, (door-chime), pre-alarm O.C., zone state O.C.,
alarm messages on keypad, memory of pre-alarm events.
- 29 -
from previous
page
[b] Tamper: it is an anti sabotage zone, that cannot be by passed. The alarm stops after entering a USER
CODE.
[A] Key AREA: zone programmed for the external AREA arming of the unit.
[H] Key HOME: zone programmed for the external HOME arming of the unit.
[O] Key ON: zone programmed for the external ON arming of the unit.
Note: if the option “Double zones”is activated, the configuration of the twin zone to the one used to command
an arming in any mode, must be as “Not Used”. On the contrary, in order to warn about the wrong
programming, the keypad will show “Mistake prog. # 1”
Note: the zones from 11 to 88 are factory-programmed as ( c ) Not Used
N.B. the zones setted as “24 hours” for robbery segnalling, must not activate the alarm relay.
IMPULSIONS
Pulses
ENT
éê
Zone Number 1
(max. 88)
Number pulses
1 (max. 10)
Press on (CLR) to vary
Write number of impulsions
Press on (ENT) to confirm
Press on (ESC) to go back
A different pulse counter can be programmed for each
zone. A zone is just activating an alarm after a few detection
of this zone, equal to the value of the pulse counter of this
zone in a period programmed.The default value is one.
! Note
The interval of time is programmed with the parameter
“Interpulse Time” in the menu “Prog. Timings”; elapsed
this time, the counter is resetted.
If the zone stays open for 30 seconds will generate in any
case an alarm, independently from the number of the programmed pulses.
O.C. zone
Zone O.C.
ENT
éê
Zone number # 1
(max. 88)
First O.C.
0
(max.40)
Second O.C.
0
(max.40)
Third O.C.
0
(max.40)
Fourth O.C.
0
(max.40)
For any input line of control unitit is possible to associate max.
4 state or zone alarm O.C.
First OC 1
Set the open collector to be activated for the unbalancing of the
line
Second/Third/Fourth O.C.
Set the open collector to be activated for the unbalancing of the
line
Note: the O.C. Set must be programmed in the menu
as state or zone alarm O.C.
O.C.
ÊPress (CLR) to vary
ÊWrite O.C. number to activate
ÊPress (ENT) to confirm
ÊPress (ESC) to go back
ÊPress (é) e (ê) to mouve
ENT
to following
page
- 30 -
éê
from previous
page
Options
ENT
éê
OPTIONS
Memo Alarm
ENT
éê
Memo Alarm
1
YYYYYYYYYY
Memo Alarm 11
YYYYYYYYYY
Memo Alarm 25
YYYYYYYYYYYYYYYY
Memo Restore
ENT
éê
Memo Restore 1
nnnnnnnnnn
Activ. Buzzer
ENT
éê
Activ. Buzzer
Chime
ENT
éê
Chime
nnnnnnnnnn
1
Door
ENT
éê
Door
nnnnnnnnnn
1
1
YYYYYYYYYY
Prealm. Memo
ENT
éê
Prealm. Memo 1
nnnnnnnnnn
Tamper detection
ENT
éê
Tamper detect. 1
nnnnnnnnnn
Under Test zones
ENT
éê
Under Test zo
nnnnnnnnnn
1
Void survival
nnnnnnnnnn
1
Tamper exclude
NO
Alarms counter
0
(max. 10)
Void survival
ENT
éê
Press on (CLR) to be able to vary
To move in the desired position press
ç) (è
è)
on (ç
Press on (CLR) to vary
Press on (ENT) to confirm
To enter other options press on (é)
In this menu you can program the secondary functions of each zone.
Memo Alarm and Memo Restore: The alarm provoked from the opening
of the zones and the consequent closing can be registered on the memory
events of the control unit; Inserting “YES” the function will be activated
and vice versa.
Active Buzzer: The alarm provoked from the zones programmed with
“YES” will provoke the sound of the buzzer of the keypads; the sound
time must be programmed in the Timers Menu.
Chime: a detection on a zone(s) day mode (panel Disarmed). When the
panel is disarmed, the buzzer sounds on the keypad(s); to stop it, the
enabled USER CODE(s) must be entered.
Example: useful to control the EMERGENCY exits.
Door: When the panel is disarmed, and a door zone is open, the buzzer
sounds on the keypad display and stops in a time if the “door time”
Pre-alarm memory – the unbalancing of the inputs zones set as type of
zone with pre-alarm can be kept in the events memory of the control unit;
a YES will follow the setting of “Alarm memory” whilst a “NO” will not
keep the alarm in memory
Tamper detect: each zone can be programmed in the double resistor
configuration. This is meaning that it is possible to differentiate an alarm
and a tamper fault on the zone.
Under test zones: an alarm on a zone in test is only activating the
programmed open collector outputs and the dialler, NO sirens or relays
are activated. This event is stored in the memory, if the MEMO alarm for
this zone is programmed “YES”. The green LED on the keypad is flashing
to indicate that there are one or more zones in test.
Tamper exclude: programming “YES” when a zone is excluded, it’s
excluded also the tamper zone (Not available for Belgium)
Alarm Counter: with this function it is possible to limit the alarm sequences
for successive alarms on the same zone(s). If the successive alarms are
over passing the value programmed in the ALARM COUNTER, then:
• No new alarm cycles are starting.
• The alarm are counted and stored in the event memory as MULTI
ALARM.
• A new cycle of alarms on this zone is starting if there was an alarm
on another zone (it is recommended to install only one device for each
zone).
The range is 0 to 10:
• if “0”: alarm counter is NOT activated;
• if “1” to “10” : alarm counter is activated.
E.g. A detector fault will cause the maximum programmed alarm cycles
and the other alarms will be only stored as multi alarms.
Void survival . The zone for which the function has been enabled
does not cause the indication and memory of the event.
Zone: And Zone
AND ZONE
ENT
éê
AND pair #
Inactive
1
AND pair # 1
AND
1< - > 1
AND pair # 1
AND
1-all
Directive AND
NO
to following
page
To program in AND two zones means that they must both be unbalanced within the programmed
time in order to activate the alarm outputs. To completely de-activate the AND ZONE function,
set “DE-ACTIVATED” on all couples.
AND pair # 1
Inactive
é) or (ê
ê) to have access to all other AND couples,
ÊPress onto (é
Êpress several times onto CLR until the type of AND required, in order
AND pair # 1
to vary the type of AND
AND
1< - > 1
ç) (è
è) to move in the field “first” zone
ÊPress onto (ç
ÊPress onto (CLR) to vary the field “first” zone
AND pair # 1
AND
0 < - > 1 Êselect the “first” zone and press onto (ENT) to confirm, OR
ç) (è
è) to move on the field “second” zone
ÊPress onto (ç
ÊPress onto (CLR) to vary the field “second” zone
Êselect the “second” zone and press (ENT) to confirm
AND pair # 1
AND
1< - > 0 ÊPress onto (ESC) to exit, OR
é) o (ê
ê) to have access to all other AND couples
ÊPress onto (é
Total (1 – all) : the control unit operates in such a way that the alarm detection coming
from the zone in AND, occurs as soon as another zone is alarmed
Not Directional: the control unit operates in such a way that the alarm detection coming
from the zones in AND occurs only if they are both alarmed.
Directional: the control unit operates in such a way that the alarm detection coming from
the AND zones, occurs only if alarmed in growing order
- 31 -
from previous
page
Second profile
The menu is active only if set in this way during INSTALLATION
For any zone of the control unit it is possible to activate the secondary profiles
The zone acquires this profile if it has been activated to do it and it changes its programming according to setup of
secondary profile.
When the area is disarmed, the zone is always coupled to the basic profile.
The state of the zones as shown on keypad or to the associated OC outputs, refers to both profiles, if the zone is
activated in secondary profile.
The conditioned arming refers to the type of zone set in the arming mode, which activates.
The zones programmed as Tamper, can NOT be set in the secondary profile in other types of zone.
In that case, the keypad would show a programming mistake indication “MISTAKE PROG # 2”
Se così fosse, la tastiera fa comparire un’indicazione di errore di programmazione “ERRORE PROG # 2”.
Second.profile
ENT
éê
Sec.prof.arming
ENT
éê
Zone number # 1
(max. 88)
Activation of secondary profile in ON – HOME – AREA
Arming: OHA 1
nnn
Arming: OHA 1
nnn
For any zone of the control unit it is possible to activate
the secondary profile.
First line shows the arming mode
Second line shows whether the zone is activated or not to the secondary
profile for one or more arming modes
Setting “Y” the secondary profile is activated
Setting “N” the zone will mantain the basic profiles
Once activated the secondary profile, in one or more arming modes, the zone will feature all the characteristics listed below for
those arming modes.
The zone features, not included into “Secondary Profile” are fix for any single zone and do not vary according to the arming
set.
Setting “Y” the function will be activated
Setting “N” the function will not be activated
Sec.prof.type
ENT
éê
Not Used
----------
Sec.Memo All.
ENT
éê
Sec.Memo All. 1
nnnnnnnnnn
Sec.Memo Rest
ENT
éê
Sec.Memo Rest 1
nnnnnnnnnn
Sec.Act.Buzz
ENT
éê
Sec.Act.Buzz.
nnnnnnnnnn
Sec Chime
ENT
éê
Sec Chime
nnnnnnnnnn
1
Sec.Door
ENT
Sec.Door
nnnnnnnnnn
1
éê
1
Sec.Profile Type: set the type of zone, which the zone will have in
the secondary profile
1
Sec.Memo Alarm and Memo Restore: The alarm provoked from the
opening of the zones and the consequent closing can be registered on the
memory events of the control unit; Inserting “YES” the function will be
activated and vice versa.
Sec.Active Buzzer: The alarm provoked from the zones programmed
with “YES” will provoke the sound of the buzzer of the keypads; the
sound time must be programmed in the Timers Menu.
Sec.Chime: a detection on a zone(s) day mode (panel Disarmed). When
the panel is disarmed, the buzzer sounds on the keypad(s); to stop it, the
enabled USER CODE(s) must be entered.
Example: useful to control the EMERGENCY exits.
Sec. Door: When the panel is disarmed, and a door zone is open, the
buzzer sounds on the keypad display and stops in a time if the “door time”
Sec relè zone
ENT
éê
Sec. Sir. zone
ENT
éê
Sec.CP relè
ENT
éê
Active by Zone
ENT
éê
Sec.Rele esp. 1
ENT
éê
Active by Zone
ENT
éê
Sec.Rele esp. 4
ENT
éê
Active by Zone
ENT
éê
Sec.Rele esp. 1
ENT
éê
Active by Zone
ENT
éê
Sec.Rele esp. 4
ENT
éê
Active by Zone
ENT
éê
Active by zone (relay) – it allows or not the relay activation
Set “N” to determine which zones will have to transmit a silent alarm
only.
Set “Y” to activate the relè.
Active by zone (sir.) - it allows or not the activation of the output
“Sir” on SAT03
Set “N” to determine which zones will have to transmit a silent alarm
only.
Set “Y” to activate the “-sir”.
- 32 -
da pagina
“Zone”
Arming modes
ENT
éê
ARMING
Active in ON
ENT
éê
Active in ON
Active in HOME
ENT
éê
Active in ON
Active in AREA
ENT
éê
Active in ON
Enable Quick Arm
NO
Active in ON
1
YYYYYYYYYY
11
YYYYYYYYYY
25
YYYYYYYYYYYYYYY
41
YYYYYYYYYYYYYYY
Conditional Arm.
NO
First line shows the chosen mode
The second one shows if any zone will be armed as per configuration chosen or will be disarmed
Press on (CLR) to vary
Press on (ç) or (è) to move flashing slider in correspondence
of the zone which has to be on or off at the system arming
Press on (CLR) to vary
Press on (ENT) to confirm
Use arrows (é) and (ê) to move to a group of other zones if
existing
Set “S” to determine which zones will have to be detected at
the arming
Set “N” to determine which zones will have to be excluded at
the arming
The control panel can be armed in three different modes;
for each of them can be established which line will be
inserted or automatically excluded. So that it is possible
obtain an easy and automatic partial arming of the
installation.
Active in ON (Example: total arming)
Active in HOME (Example: first floor arming)
Active in AREA (Example: ground floor arming)
These three arming modes (ON, HOME and AREA) can
be activated from the keypad and/or from external
commands.
Quick Arm Function (fast arming)
Setting this option with “YES” it is possible arming the unit
in the simplest way reassumed in Annex A.
(ON)+ (ON)+ (ENT)= “ON arming”
(HO)+ (HO)+ (ENT)= “HOME arming”
(9)+ (9)+ (ENT)= “AREA arming”
Conditional Arming (forced arming)
Setting “NO”, the unit will switch-ON even if there is an
unbalanced zone(s).
Setting “YES”, the unit wont Switch-ON if there is an
unbalanced zone(s).
TAMPER
Tamper
ENT
éê
TA Output Time
60
(0:255 sec)
Activ. CP Relay
YES
Activ. Relay
1
NO
Activ. Relay
4
NO
Activ. Siren.
1
NO
Activ. Siren.
4
NO
The dedicated TAMPER input line (TT) and the input lines programmed as
“Tamper” (see Chapter 18) can activate the alarm relay and the open collector
output (O.C.) dedicated to the Tamper alarms (TA).
0• TA output time: time of activation of the O.C. output dedicated to the
Tamper (TA)
• Active Control Panel Relay: control panel relay
• Active Relay 1: Satellite 0 relay
• Active Relay 2: Satellite 1 relay
• Active Sir 1: modulated output (Sir.) in Satellite 0
• Active Sir 2: modulated output (Sir.) in Satellite 1
• Memo TAMPER Alarm: Memorization of the Tamper Alarm
• Memo TAMPER Restore: Memorization of the Tamper Alarm Restore
• Active Buzzer: Active the signalling of the Buzzer in the keypads.
MemoTamp.Alarm
YES
MemoTamp.Rest.
NO
to following
page
Activ. Buzzer
YES
- 33 -
from previous
page
Fire
ENT
éê
FIRE
Detector Current
20
(5:35 mA)
Activ. CP Relay
YES
Activ. Relay
1
NO
Activ. Relay
4
NO
Activ. Siren
1
NO
Activ. Siren
4
NO
Detect current: default value 20mA.
functioning
The special fire input (only in SAT 03) allows two wires connection with 12 Vsmoke detectors.
The alarm is detected from absorption changing; the threshold can be settled
during the control panel programming.
All the detectors must be connected in parallel on the same line.
+: supply positive output 12V-, protected from fuse F2.
F: balanced input, with resistor of 4,700 ohm, for smoke detectors (absorption
of current).
Memo Fire Alarm
YES
Operation of the FIRE line
•The alarm situation of a smoke detector stays up to a manual reset.
1) insert the USER CODE enabled to this reset operation and the alarm status
will be blocked. The detector that has generated the alarm will still remain with
the alarm led ON.
Memo Fire Rest.
NO
2) Pressing the key [2] (Res. Fire) is provoked the detectors reset, removing the
supplying to the detectors automatically for 10 [sec].
Activ. Buzzer
ATTENTION
YES
The performances of the Fire line are not certified according to the Norm CEI 79RELAYS
Relays
ENT
éê
Ctrl.Panel Relay
ENT
éê
Relay Time
MM:SS 3 : 0
Activ.by Zone
ENT
éê
RCtrl Feedback
NO
RCtrl Feedback Dur
Very short
Relay on Exp. 1
ENT
éê
Relay on Exp. 4
ENT
éê
Relay Time
MM:SS 3 : 0
Control unit relay
Relay time: (Bistable, MM :SS)
Activation by the zones
Remote Control Reply
Setting YES the control panel relay is activated when the arming/
disarming command is correctly executed
Duration of Remote Control Pulse
Select the duration of the relay activation according to the
acoustic reply required
Relay extension board 1
Relay time (Bistable, MM :SS)
Activation by the zones
Relay extension board 4
Relay time: (Bistable, MM :SS)
Activation by the zones
Activ.by Zone
ENT
éê
Relay Time
Setting (MM :SS) temporized in minutes
Setting (Bistable) always active
Relay Time
MM:SS 3 : 0
Press on (CLR) to vary
Write number o set
Press on (RNT) to confirm
Activ.by Zone
ENT
éê
Set “N” to determine which zones will have to transmit a silent
alarm only.
Set “YES” to activate the siren.
SIRENS
Sirens
ENT
éê
Siren on Exp.
1
ENT
éê
Siren Time
MM:SS 3 : 0
As previous parameters
Modulated outputs, present on SAT 3 extension boards, can be
associated to the input zones of control unit and its activation
time is programmable.
Activ.by Zone
ENT
éê
Siren on Exp.
4
ENT
éê
Press on (CLR) to vary
Write number to be set
Press on (ENT) to confirm
Siren Time
MM:SS 3 : 0
Take care ! These outputs are modulated additional outputs,
they are not the sirens of the system which are usually
connected into relays.
to following
page
Activ.by Zone
ENT
éê
- 34 -
from previous
page
O.C.
ENT
éê
to following
page
OPEN COLLECTOR
O.C. # 1
(max. 40)
Category
Unused
The (CLR) pushbutton will visualize all possible functions.
A specific menu is available for any function.
OC Act. Time
inactive
ÊPress (CLR) to vary
ÊPress (ENT) to confirm
ÊDial the number chosen
é) (ê
ê) to move
ÊPress (é
ç) or (è
è) to move the flashing clip
ÊPress (ç
Subfunction
Unused
ZONE cat.
Sub-function:
Alarm: it activates with the alarm state of at least one of the associated zones
Re-balancing: it is active with the balancing of all associated zones
Exclusion: it activates with the exclusion of at least one of the associated zones
Pre-alarm:it activates for the pre-alarm of at least one of the associated zones
Unbalancing:it activates with the unbalancing of at least one of the associated zones
Tamper: it activates with the tamper of at least one of the associated zones
Not used: it will never activate
ARMING cat.
It activates when the area is armed in ON, HOME, AREA, DISARMING modes
Controlled area: set the reference area (with 0 set to S , the output is active when all areas are on)
Arming (type of arming): select the type of reference arming (O=On – H=Home – A=Area – D=disarming)
Alarm memory (RK32): setting “YES”, in disarmed condition, it flashes if an alarm has
occured during previous arming
ARMED cat.
Code: setting “YES”, it activates when the associated User Code is dialled (see User’s Profiles)
Emergency code: setting “YES”, it activates when the associated Emergency User Code is dialled (see User’s Profiles)
Key: setting “YES”, it activates when the serial key board recognizes a key
Emergency key: setting “YES”, it activates when the serial key board recognizes an emergency key
AREA cat.
Subfunction:
Not used: it will not activate
Alarm: it activates with the alarm state of the area
Re-balancing: it activates with the rebalancing of all associated zones to the the selected area
Exclusion: it activates with the exclusion of at least one of the area zones
Pre-alarm: it activates for the prealarm of at least one of the area zones
Unbalancing: it activates with the unbalancing of at least one of the associated zones to the selected area
Tamper: it activates with tamper of at least one of the area zones
controlled area: set the reference area
Nota: O.C. Cat. Settore: se associato a 0 (zero), si attiverà per una delle zone associate al settore 0.
USER cat.
It’s activated by RTC, on keyboard, dialling a user’s code with activation of “Activation User’s O.C.”, or by Timer
controlled area: set the reference area
SUPPLYING cat.
Mains absence: with “YES” it activates for absence of the mains, after a programmable minutes delay (see “Time”)
Low battery: with “YES” it activates when the battery of control unit or of Power1/4, connected to Sat03, goes lower than 10,5
Volt,
missing recharge tension. It resets when the tension increases over 12.8 Volt
Missing battery: with “YES” it activates when the battery of control unit or of Power1/4, connected to Sat03, is damaged or
disconnected
TELEPHONE DIALLER cat.
Absence of telephone line: with “YES” it activates when the prsence of the telephone line
During telephone call: with “YES” it activates during a telephone call
is not detected any more
FIRE cat.
It activates when there is a FIRE alarm coming from one of the satellites
KEY ACCESS cat.
It activates when a key acquired on board is read by a reader connected in COD1 or COD2
TIMER cat.
It activates when the Timer reaches the date and time set; it cannot be operated by the user.
TIME MANAGEMENT
De-activated: the output does not activate
Bi-stable: the output follows the state of the associated zone
Special blk: the output will follow the state of the associated function activating in pulse mode in case it is excluded
MM:SS: the output will activate for the time set; MM = minutes / SS = seconds
HH:MM: the output will activate for the time set; HH = hours / MM = minutes
DD:HH: the output will activate for the time set; DD = days / HH = hours
Note - Special Blk: this option appears only in the steps where it can be programmed
Note - “Time”: the values set could be automatically made round after confirmation with ENT
- 35 -
from previous
page
Timings
ENT
éê
TIMING PROGRAMMING
Exit Time 1
Inactive
Entry Time1
Inactive
Sec.Entry Time 1
Inactive
Exit Time 2
Inactive
Entry Time 2
Inactive
Sec.Entry Time 2
Inactive
Exit Time 3
Inactive
Entry Time 3
Inactive
Sec.Entry Time 3
Inactive
Prealarm time 1
Inactive
Prealarm time 2
Inactive
Prealarm time 3
Inactive
Tempo preall. 4
Inactive
Buzzer Time
MM:SS 1 : 0
Interpulse Time
60 (0:255 sec)
AND ZONE Time
60 (0:255 sec)
Offset Mains OFF
20 (0:255 min)
Buzz. DOOR time
255 (0:255 sec)
Buzzer RTcrl time
0 (0:20 sec)
Survival time
120 (40-255min)
Exit Time 1- 2- 3
Output Time from temporized zone 1 - 2 - 3 and 24H temporized 1 - 2- 3
Entry Time 1 - 2 - 3
Input Time of temporized zone 1 - 2- 3 and 24H temporized 1 - 2 -3
Secondary Entry Time 1 - 2 - 3
Input Time of the temporized zone with temporary exclusion 1 - 2 - 3
Preallarm Time 1 - 2 - 3 - 4
Pre-alarm Time of the Immediate zones with pre-alarm 1 - 2- 3- 4 and of the
zones
Interpulse Time:
programming of the time interval during which it will be counted the zone
openings, to generate an alarm
Buzzer Time:
programming of the alarm time of the keypads. Inserting the value 0 (zero) the
buzzer is disable.
AND ZONES Time:
the AND ZONES time defines within which time the opening of the lines in
“[and]” must generate an alarm.
Offset Mains OFF:
programming of the time after which the control unit will send the communication (or alarm of assigned alarm outputs).
Buzzer DOOR time:
programming of the buzzer door time of the keypads. Inserting the value 0 (zero)
the buzzer is disable.
Remote Control Buzzer Time (TCM)
Buzzer activation time on keypad when the arming/disarming command is
correctly executed
Survival time:
It’s the interval not later than a detector has to transmit supervision to unit
control
Maintenance Period:
programming of the visualization on Keypads the “maintenance Per” in a
managed time.
Messages latency:
the old messages are visualized on keypad only for the managed time. After
this time the User is informed to see the event memory.
ATTENTION: the memorization in the “memory events” is registered at the end of
the delay.
TIME MANAGEMENT
Not programmed: the output does not activate
Bi-stable: the output follows the state of the associated zone
MM:SS: the output will activate for the time set; MM = minutes, SS = seconds
HH:MM: the output will activate for the time set; HH = hours, MM = minutes
DD:HH: the output will activate for the time set; DD = days, HH = hours
Note “Time”: the values set could be automatically made round after confirmation
with ENT
ÊPress (CLR) to vary and select whether Bistable or one of the pulse modes
ç) o (è
è) to move the flashing sliding clip
ÊPress (ç
ÊWrite the number to set
ÊPress (ENT) to confirm
Maintenance Per.
0
(max. 24)
to following
page
Messages latency
255 (max. 255h)
- 36 -
from previous
page
Service codes
ENT
éê
SERVICE CODE
Installer code
ENT
éê
Installer code
ââââââ
Installer Code: In this menu the INSTALLER CODE can be changed.
Prog.when Armed
NO
Prog. when Armed: the INSTALLER CODE can be operative also if
the control panel is armed. to disable this function set “NO”.
Each code can have 4, 5 or 6 digits.
The Default value is 000000 (six zeroes).
! IMPORTANT ANNOTATION!
If the value is set to “YES” , the INSTALLER CODE is operative with the control unit armed, the IMQ omologation is over.
The INSTALLER CODE is resetting: existing tamper alarms - alarm phone calls.
Elapsed 2 minutes after the last inserting, the installer menu is automatically closed.
It is possible set this time to 60 minutes, entering the “menu stand by”; in that way you can have a longer time to make
maintenance.
Communic Code
ENT
éê
Access Password
ENT
éê
Programm.Passw.
ENT
éê
Communic Code
ââââââ
Access Password
ââââââ
Programm.Passw.
ââââââ
Communication Code
It is the code that, once entered in the keypad, active a communication
with XS40 for direct reprogramming, or the downloading of the memory
events. the default number is: to set.
• Example: Comm. code for the reprogramming with XS40
• Example: Comm. code for the Memory Events downloading
Access Code
It is a code composed from 6 digits (memorized in the EEPROM of the
control unit); the default value is 000000.
In the Winrec software, must be memorized a Code of Access,
composed from 6 digits, for each Logitel 8 Plus Advance existing.
These two Access Codes (control panel and Winrec) allow activating
the Ring Back function for a remote reprogramming.
Programming Code
It is a code of 6 digits memorized in the EEPROM of the control panel; the
default code is 000000 (6 zeroes).
In the Winrec software, must be memorized a Programming Code,
composed from 6 digits, for each Logitel 8 Plus Advance existing.
These two Programming Codes (control panel and Winrec) allow the
transfer from the computer to the control unit Logitel8Plus Advance of
the configuration program; the transfer could be activated from the
Code of Communication entered in the keypad of the control panel or
from the function Ring Back.
USER CODES
User codes
ENT
éê
Code #
1
(max. 64)
Code #
ââââââ
Active Code
YES
User prof.. #
1
(max. 8)
control.Sector
ENT
éê
Sector sum
Master user
to following
page
NO
NO
Double consent
NO
There are 64 USER CODEs that allow the complete management of the control panel.
The default values are:
USER CODE 1: 000010 Emergency Code 1: 000011
USER CODE 2: 000020 Emergency Code 2: 000021
USER CODE 3: 000030 Emergency Code 3: 000031
USER CODE 64: 000640 Emergency Code 64: 000641
The Emergency Code is activated when one unit is added to the last digit of the
corresponding USER CODE
USER CODE programming
Each USER CODE can be programmed to obtain different operations:
Active Code: with “YES” the code is active.
Profiles User: the code must be associate to one of 8 profiles, the profiles are the attributes
of the code.
Sector (partition) control: the code must be associated to sector (partition) 1, 2, 3, 4 and
the code could manage only in that sectors (partitions), or to more sectors if it is enabled
to operate in more sectors (partitions).
Sectors:1234
Sector sum: with “YES” the user code is enabled to operate at the
Ynnn
same time on more sector after the digit of 0 (zero)
Master User
If the User is enabled to Master, the code will have priority on the keyboards, it will then
be able to operate on its area also from keyboards which are not ususally concerned.
Further to this, it will have other functions as described in the chart “MASTER USER
QUALIFICATIONS”. Some functions are subject to activation in “User Profile”.
Double consent (on A600Plus reader only)
“SI” activates the possibility of dialling the code for 20 seconds, only after the key associated
to the user has been brought near to the A600Plus reader
MASTER USER QUALIFICATIONS
Function
Profile Activation
Change vocal tel. Numbers of concerned area
Change par.tel: Yes
Vary Sim Card credit expiry
Change par.tel: Yes
Change A600Plus keypad configuration
-
- 37 -
from previous
page
User profiles
ENT
éê
USER PROFILES
User prof. #
1
(max. 8)
Arm in ON
Arm in HOME
Arm in AREA
Disarm Panel
YES
NO
NO
YES
Immediate Disarm
NO
Disarm timer-arm
NO
Activat.Overtime
NO
Date/TimeChange
NO
Code Change
YES
Change tel .
YES
Memory View
YES
OFF ZONE func.
YES
Enable User OC
NO
Buzzer Exclusion
YES
Code Communicat
NO
Comm.Emer.Code
NO
Enable RTC.Func.
NO
Stop Dialler
NO
Autom Valid. RTC
YES
RTC A600Plus
YES
Test Outputs
NO
Reset Fire Loop
YES
Off Timers enab.
NO
to following
page
to following
page
The User Profiles are the attributes of each code, it manages the control panel
respecting the programming of the user profiles set for the code.
Arm in ON:
with “YES”, this code is enabled to arm in ON status.
Arm in HOME:
with “YES”, this code is enabled to arm in HOME status.
Arm in AREA:
with “YES”, this code is enabled to arm in AREA status.
Disarm panel:
with “YES”, this code is enabled to disarm the panel.
Immediate disarm: with “YES”, this code is enabled to disarm the panel without
using the key 5 after the code. (note: this function is valid only if the code is
enabled to disarm)
Disarming in Watch:
with “YES”, this code is enabled to disarm the panel even if previously automatically
armed with the watch.
With “NO”, the Code hasn’t the possibility of disarming the control panel, up to the
automatic disarming from the watch.
(note: this function is valid only if the code is enabled to disarm)
Activation Overtime:
with “YES”, this code is enabled to activate the overtime period of one hour for a
maximum of three times.
Date and Time Change :
with “YES”, this code is enabled to change the date and Time.
Change Code:
with “YES”, this code is enabled to change itself.
It changes telephone dialler parameters:
"YES" enables the Code to the possibility of varying/verifying telephone parameters:
- Telephone numbers associated to the User
- Area Telephone Numbers if the Code is Master
- Check of remaining credit on Sim Card
- Check of GSM net
- Variation of the Sim Card expiry if the Code is Master
Memory view:
with “YES”, this code is enabled to examine the memory events of the control
panel.
OFF ZONES function:
with “YES”, this code is enabled to make the zones by pass.
Enable User OC
with “YES”, this code is enabled the user code to activate O.C using Keypad or in
RTC mode.
Buzzer exclusion:
with “YES”, this code is enabled to exclude the sound of the buzzer of the keypad.
Code Communication:
with “YES”, each time this code is entered, the control unit will send a phone call.
Code Communication Emergency:
with “YES”, each time the emergency code (corresponding to this code) is
entered, the control unit will send a phone call.
Enable RTC functions:
with “YES”, this code is enabled to access to the RTC function.
Stop dialler:
with “YES”, this code is enabled to stop the phone calls.
Valida automatic RTC
“YES” enables the code to the possibility of entering directly into RTC with no
need for code confirmation, after dialling 7 after a telephone call or in RTC
connection from the GSM module.
RTC A600Plus
“YES” enables the code to the possibility of entering directly into RTC on
A600Plus Keypad, after dialling user code and 7.
Test Outputs:
with “YES”, this code is enabled to test the alarm outputs for a period of 3 seconds.
Reset Fire loop:
with “YES”, this code is enabled to reset the FIRE alarm
Off Timers enab.:
with “YES” the user code is enable tl set the timing zone as instantaneus.
- 38 -
from previous
page
from previous
page
Act. O.C.
0
(max.40)
Emergency O.C.
0
(max.40)
Istant.Key mode
NO
output on EB3
ENT
éê
Active O.C.:
with “YES” each time the code is entered an Open Collector Output will be activated
Emergency O.C.:
Open collector output associated to the USER CODE. This code is automatically
generated from the microprocessor and cannot be changed. It is also possible the
association of this Emergency Code to an Open Collector Output that will be activated
when entered the code itself.
Instant.key mode:
with “YES” the touch associated to this user profile to operate in instantaneus mode
even if the board is setted in an other modality.
key ser.device:
to enable the outputs on EB3 board when a touch is on RD.
Activable output
NO
Boards outputs which can be activated:
“SI” allows the activation of local open collector outputs on key board
Output inp. COD1
1
(max..4)
Output from entry (COD1)
It is set as local Open Collector output on EB3 board, which must be
activated at recognizing of the Key (Touch)
Output inp. COD2
1
(max..4)
R.Ctrl Progr
ENT
éê
Funct.KEY prog.
ENT
éê
Output from entry (COD2)
It is set as local Open Collector output on EB3 board, which must be
activated at recognizing of the Key (Touch)
Key num# 0
(max. 8)
Key num # 1
No operation
O.C. #
(max. 40)
Key num # 1
Activate O.C.
éê
1
Sector
#
0
(max. 4)
1
2
5
3 4
éê
Key num # 1
Arm.ON Sect.
PROGRAMMING OF CHANNELS ON REMOTE CONTROL
Select the Pushbutton Function from 1 to 5+4 according to
p u sh
the conversion chart
p u sh
C h an el
C h an el
button
button
“Channels –
5
•
5+1
1
•
1
Pushbuttons”
6
•
5+2
2
•
2
3
4
Emerg. Keys
ENT
éê
•
•
3
4
7
8
•
•
5+3
5+4
Emerg. Keys
nnnnnnnn
CHANNELS Functions
- None: no function associated
- Arming ON/HOME/AREA/Disarming – AREA ? : the pushbutton is associated to arming/disarming of
one or more areas; if set on area 0 (zero) the command will operate on all areas associated to the user(*)
- Dispatch: Panic/Medical/Fire: the pushbutton is associated to panic/medical/fire indication
- OC activation/de-activation ? : the pushbutton is associated to the activation/de-activation of the O.C.
output. It must be programmed as “User cat.”
- OC commutation: it varies the condition of the O.C. output; it activates it if it is off, it de-activates it if it is
on. It has to be programmed as “User Cat”
(*) the reply (keypad beep or control panel relay) of the operation made will activate only if the required
operation is entirely executed on all areas. Whenever an area is on in a mode lower than the one
required, there will be so reply to the operation and that area will remain in the initial condition
Emergency Channel.
Note: if the emergency option is enabled (YES), at the same time of the operation associated to the
pushbutton, the emergency code function will also activate.
Working of pushbuttons:
Pushbuttons from 1 to 4 directly activate the function to which they are associated.
The second group of pushbuttons activates for contemporary pressure of pushbutton 5 (the central one)
followed by one of the other pushbuttons.
ÊPress (CLR) to vary
ÊWrite the pushbutton to be set
ÊPress (ENT) to confirm
to following
page
- 39 -
from previous
page
Readers
ENT
éê
READERS
Arm. input
ENT
éê
Remote Mode
Pulse Mode
Disarm if Watch
NO
See note
below
In this menu it is possible to program the working of the
zones of external arming for a key board. Entering and
leaving this menu, we will have the disarming of all
pending arming.
Working mode of the key
At status: when an arming input is balanced by its
resistance, the control panel is disarmed; when the
resistance is opened or short-circuited, the control panel
will result to be armed. Example of arming addition: the
arming by keypad and the closing of the input arming
cause an addition of arming, resulting in the following: in
order to have the control panel back to the status of
disarmed, the arming terminal board must be open and
the keypad must be off.
ATTENTION when two arming add, the most important
one in the hierarchy prevails
Pulse Mode: the closing and following re-opening of an
arming input causes the arming of the control panel in the
concerned mode; a new pulse will determine its
disarming. With this setting the control panel can be armed
and disarmed no matter if by keypad or by an arming input
with no limits.
Disarming with active PO (timer): with a YES, the external
arming are enabled, e.g. “electronic keys” to disarm the
control panel previously armed by a PO (timer). With a NO,
in order to disarm the control panel it is necessary to wait
for the automatic disarming by the PO (timer), or disarm
by keypad with a User Code enabled to disarm with active
PO (timer).
ERR.N.2 s .# n..
CLR(no) ENT(yes)
EB3 / RS
ENT
éê
EB3 / RS.#
0
(max. 8)
EB3/RS reader: this menu allows the programming of the functions
of the key-board EB3 or of the serial readers
EB3/RS: select the key-board or the serial reader to program
Note: EB3/RS reader are defined as “peripheral” in following pages
control. sector
ENT
éê
Sector: 1234
Ynnn
Parameters
ENT
éê
Command mode
single
Settore control. (controlldr partition)
– Sett by (s) the peripheral is associated
to the partition
The peripheral can be associated to
operate to one or more partitions
Command Mode:
Single: in this mode the peripheral can be associated to one or more partitions and
when the key is approached to the reader, the user is offered various possibilities of
arming. If the peripheral is associated to more partitions, the LED visualization is usually
deactivated, the visualization of a partition will be enabled after they key is recognized;
if on the contrary, the peripheral is associated to a single partition, the Led can be
programmed as normally on or normally off. The operations allowed are enabled for the
concerned peripheral.
to following
page
Immediate: in this mode the control panel operates immediately the functions
associated to the peripheral without waiting the releasing of the Touch. Anytime the
key is approached to the reader, the control panel is commuted from arming to
disarming. As far as this concerns the arming, the peripheral will always operate the
maximum priority one for which the user is enabled or the disarming. It is suggested to
to following
page
Note: if in a serial key board some Touch keys are memorized and the board is installed in a new system, the keyboard shows a
warning message:
“ERR.N.2.chiave” (mistake N. 2 key board). To make the board operative, it is necessary to record it inside menu “Sch. Chiave ser”:
Or, to reset original conditions of the board, follow procedure for cancellation of all keys.
- 40 -
from previous
page
from previous
page
COD2/RS Abilitat.
ENT
éê
Work if CP arm.
YES
Works only outp.
NO
Norm. Light. LED
NO
Memo. false key
NO
COD2/RS=emerg
NO
Output pulse
Slow
Memo state read
NO
Activable output
ENT
éê
OC key rec.
0
(max. 40)
OC emergen. key
0
(max. 40)
Arming: OHA-D
nnnnn
COD2/RS abilitation:
to programm the function of the COD2/RS input (arming mode)
Accens: OHA-D: con “YES”, enable the input
“COD2” to make arming and disarming of
control panel.
Parameters
Work if CP arm.: with ”YES” the serial proximity key (EB3) could
operate with the armed CP
Work only output: with “YES” the serial proxmity key (EB3) operates
only output and not the arming
Norm.light LED: with “YES” the LED on reader are light; this function
is active only if the EB3/RS is associated to one sector
Memo. false key: with “YES” the false key is enabled to be saved
on event memory
Inp.COD2/RS =emerg.: with “YES” the input COD2/RS is an emergency input.
Output pulse(only EB3): setting Slow / Fast to change the timing of
the EB3 output
Memo state read: with “YES” is enabled the memorization of touch
reading
Activable output(only EB3): with ”YES” is enabled the EB3 output
OC key rec.: select the Control Panel O.C to activate when a touch is
recognized
OC emergency key: select the Control Panel O.C to activate when
an emergency touch is recognized
Output:
1234
nnnn
Activable output: (active board outputs): setting out “YES” local active outputs on EB3 board are enabled to recognize user-Key
O.C. key rec :
Chose open collector to activate from 1 to 40 in case the key is
recognized.
O.C. emergen. key (O.C. Emergency Key):
chose open collector to activate from 1 to 40 in case the
emergency key is recognized
RD on A600 Plus
A600Plus
ENT
éê
Keypad Num.#
0
(max. 8)
User Code: in this mode the keypad can be associated to one or more areas, and
when a key is brought near to the reader , it directly goes to the user menu..
- If the keypad is associated to an area, it will directly visualize the area condition
- If the keypad is associated to more areas, it will visualize the possibility of choosing
on which area to operate
Command mode
user code
Immediate: in this mode the control panel instantly operates the functions
associated to the Key without waiting for the key to be removed.
If the keypad is associated to one area only, anytime the key is brought near to the
reader, the control panel will commutate arming/disarming. As far as this regards
arming, the key will always operate the max priority arming to which the key-user is
authorized or will operate disarming.
Parameters
ENT
éê
Arming
ENT
éê
Arming: OHA-D
sss s
Work if CP arm.
YES
Memo. false key
NO
OC key rec.
0
(max. 40)
to following
page
OC emergen. key
0
(max. 40)
RD A600Plus abilitation:
to programm the function of the A600Plus RD
input (arming mode)
Accens: OHA-D: con “YES”, enable the RD
input to make arming and disarming of control
panel.
Parameters
Work if CP arm.:
with ”YES” the serial proximity key (A600Plus) could operate with
the armed CP
Memo. false key:
with “YES” the false key is enabled to be saved on event memory
OC key rec.: select the Control Panel O.C to activate when a touch
is recognized
OC emergency key: select the Control Panel O.C to activate
when an emergency touch is recognized
- 41 -
From page
Readers
Accesses
ENT
éê
Accesses
Touch on EB3
ENT
éê
Tch on A600P/RS
ENT
éê
Key acquis. 1
(max.64)
Key acquis. 1
........... running
éê
Key deletion 1
(max.64)
Key deletion 1
........... running
Key acquis. 1
(max.64)
Key acquis. 1
........... running
éê
Key deletion 1
(max.64)
Key deletion 1
........... running
éê
All deletion
ENT
éê
All deletion
........... executed
éê
Key list
ENT
éê
Key list
1
nnnnnnnnnnnnnnnn
éê
Key verify
ENT
éê
Key verify
........... running
Acquisition Touch nr.
The location of the key-memory to program is
selected (CLR) - Nr – (ENT)
Acquisition Touch nr. … in progress
Possibility of acquisition of the Touch, just
approach it to the reader
Note: if the Touch has already been acquired,
the display will show the location where it is
memorized
Delete Touch nr.
The location of the key-memory to delete is
selected (CLR) – Nr – (ENT)
-----------------------------------------------------Delete All (for A600P/RS only)
(ENT) – it contemporarily deletes all Touch
memorized in control panel
Key List (for A600P/RS only)
The Touch keys acquired in control panel are
checked
Key verify (for A600/P/RS only)
Approaching the Touch to a reader, it is
possible to obtain indication on which key it is
and to which user code it is linked
Verifica key
Touch:1 A U:1 E
Chiave emergenza
Numero chiave
chiave abilitata
Prog. Key Func.
ENT
éê
key
#
0
(max.64)
Utente associato
Prog.Key Func.
Assoc. user num.
1
(max.64)
Key # 0:
select the touch to programm
Assoc.user num.:
to associate the touch to a user code
Abilitations:
to qualify a touch to work
Emergency key:
to manage a touch as an emergency key
Activated key
YES
Emergency key
NO
In this menu it is possible to program the acquisition of the keys which will have access to the control panel
-
Acquisitions:
Touch on EB3: the keys are acquired and memorized directly on the EB3 board using the RD readers connected to the
EB3 board.
Touch on A600Plus/RS: the keys are acquired and memorized on the control panel using the reader RD inserted on the
keypads A600Plus or on serial readers as RS.
Note: in order to have a TOUCH key operating on both readers connected to EB3 and to A600Plus/RS, it has to be necessarily
acquired on both sections.
The single keys TOUCH will be memorized in memory locations from 1 to 64 for the EB3 and for the A600Plus/RS. In order
to respect the enabling and the associations of the keys to the codes, it is necessary to have them acquired in the two
sections in the same order: the key acquired as 1 on the EB3 board (Touch on EB3) must be acquired as 1 also on the
A600Plus/RS (Touch on A600P/RS)
Progr. TCM
ENT
éê
TCM #
0
(max.64)
Assoc. user num.
1
(max.64)
to following
page
ASSOCIATION OF REMOTE CONTROL TO USER CODE
Remote Control Number
Select the remote control which has to be associated to the code
Association to End-User
Associate the remote control to an active End-User code: the
remote control will acquire its features
- 42 -
from previous
page
Keypad
ENT
KEYPAD
éê
Keypad Num.#
0
(max. 8)
Buzzer on Alarm
YES
Buzzer on Exit
YES
Buzzer on Entry
YES
Buzzer on Chime
YES
Buzzer on Door
YES
Beep of keys
YES
Buzz. Watch Sig.
YES
On entry com.sct
NO
Sect.mess.disab
NO
Arming: OHA
YYY
Enable Quick Arm
ENT
éê
R.Ctrl Buzz. op
NO
A600 setup
ENT
éê
For each keypad it is possible determines the operation of the
Buzzer, in the different situation as entry time, exit times and alarm.
Example:
Keypad 0: Alarm + Exit + Entry
Keypad 1: Alarm + Entry + Watch Notice
Keypad 2 and 3: only Exit
Buzzer on Alarm:
Function linked to Prog. Option / Active Buzzer
Buzzer on Exit:
Function linked to delay line
Buzzer on Entry:
Function linked to delay line
Buzzer on Chime:
Function linked to Prog. Option / Chime
Buzzer on Door:
Function linked to Prog. Option / Door
Beep of Keys:
Enable or not the Buzzer pressing user code and function
Buzzer Watch Sig.: the keypad buzzer will sound when there is
an automatic arming.
On entry com.sct.:
Function linked to common delay line
Sect.mess.disab:
It removes the visualization of the area messages; only
messages concerning commun area will be visualized
Enable Quick Arm
It is possible to enable the Quick Arm function for any
keyboard: press (ENT) to have access to the menu. Set “YES”
to enable Quick Arm for ON – HOME – AREA
TCM Buzzer of Remote Control Reply
It enables or not the keypad beep when the arming/disarming
command is correctly executed.
A600 - A600Plus setup
It is possible to enable the programming of the accessory
LEDs and of the multi-function pushbuttons: press (ENT) to
have access to the menu
Programming of Function LEDs: in this menu, it is possible to
program the activation of the 4 accessory LEDs placed on the
keyboard; it is possible to link them to the state of one Open
Collector or to associate them to the armingof an area.
Funct. LED prog.
ENT
éê
LED num. # 0
(max. 4)
LED num. #
No operation
O.C. #
1
(max. 40)
Num. LED #
O.C. assoc.
Sector
#
0
(max. 4)
Num. LED #
Arming Sect
1
éê
1
éê
1
Programming of function pushbuttons: in this menu, it is possible to
associate an Open Collector programmed as “User O.C./Sector” in the
menu “O:C: programming” to the function pushbutton A-B-C-D
Funct. KEY prog.
ENT
éê
Key num. #
1
(max. 4)
Key num. #
No operation
1
O.C. #
1
(max. 40)
to following
page
LED nr. # (max 4) :
Select the LED you wish to program
(LED 1 at the top, LED 4 at the bottom)
LED nr. #
x:
Use pushbutton (CLR) to choose the associated
function, an Open Collector or a type of arming and
confirm with (ENT) + (ENT)
Associated O.C. #:
Select the reference Open Collector
- Arming area
- Arming ON area
- Arming HOME area
- Arming AREA area
Sector #:
Select the competence area
Key num # (max. 4):
Select the pushbutton to program A=1; B=2; C=3; D=4;
Key num. #
x:
Use pushbutton CLR to select the operation:
- O.C. Commutation: it changes the state of the Open
Collector; it activates it, if it is off, and it de-activates
it, if it is on
- O.C. Activation: it activates the associated O.C.
- O.C. De-activation: it de-activates the associated O.C.
- Arming ON Area: it arms the area in ON
- Arming HOME Area: it arms the area in HOME
- Arming AREA area: it arms the area in AREA
O.C. #:
Select the reference Open Collector
Sector #:
Set the area to be activated; zero (0) activates all areas
to following
page
- 43 -
RADIO EXTENSION BOARD
From previous
page
Entering the menu of the radio extension board, it is possible to program radio detectors making their acquisition, their cancellation and signal
tests for any acquired detector.
Note: all references to the detectors have to be considered as referred to the address chosen on the detector through dips and not to the
belonging zone on control unit
Wireless expans.
ENT
éê
Sensors modify
ENT
éê
Expansion addr.
1
(max. 4)
ERR.N.2 satell.
CLR(no) ENT(yes)
See note
piè page
Modification of Detectors: in this menu the acquisition and
cancellation of radio detectors for extension board is
programmed
Extension Board address: chose on which extension board
to proceed for acquisition or cancellation of detectors.
If radio extension board is set out as double, it is not
necessary to set out “Address Extension Board 2” to work
sens.acquisition
ENT
éê
sens.acquisition
Sensors deletion
ENT
éê
Sensors deletion
1
(max. 32)
All deletion
ENT
Are you sure..??
NO=CLRYES=ENT
éê
Sat(n) Sn(n) Zn(n)
received signal
Acquisition of detectors : entering this menu, the procedure of learning of various detectors is activated for 60 minutes.
Extension board number, Detector number, Zone number: these are the references to understand which extension board has
received, which detector has transmitted and to which control unit zone is referred.
Signal received: on a bar from 1 to 8 the signal quantity received by radio extension board is in evidence
Cancellation of detectors: entering this menu it is possible to individually cancel the various detectors acquired
Reset EEPROM: entering this menu, it is possible to contemporarily cancel all acquired detectors. Once reset is made, Display will show
Sensor verify
ENT
éê
Sensor list
ENT
éê
Sensor test
ENT
éê
Sensor list
1
YYYYYYYYYYYYYYYY
Sat(n) Sn(n) Zn(n)
received signal
Note: to insert an attenuator of virtual signal; press (CLR)
once. The attenuator will be active during test only and not
during normal working of the system. On the keypad, further
to the visualization Sat(n) Sn(n) Zn(n), an “A” will be shown
Test of detectors: in this menu it is possible to check which detectors have been
actually acquired by the radio extension
board and make their test.
List of detectors: acquired detectors
are put in evidence with a (Y)
Test of detectors: it checks which radio
extension board has received, which detector has transmitted and to which zone
of control unit is referred.
Sat(n) Sn(n) Zn(n): vedi
“Acquisiz.sens.”
Remote Controls Acquisition
It is possible to acquire up to 16 (sixteen remote controls for each group (max 4) which must be codified according to the chart enclosed to
BIP.
It is not possible to acquire more remote controls with same codification in the same group and it is recommended not to acquire the same
remote control on more groups.
In order to acquire a remote control, transmit in proximity of the receiver , remembering that ACQUISITION occurs by pressing any
pushbutton except pushbutton (5)
RemCtrl modify
ENT
éê
RCtrl verify
ENT
éê
to following
page
Expansion addr.
1
(max. 4)
Remote Controls Modification: in this menu it is possible to
program acquisition and cancellation of remote controls.
Satellite Address. : select the satellite on which the procedure
of acquisition or cancellation is required.
RCtrl acquisition
ENT
éê
Group number
1
(max. 4)
RCtl deletion
ENT
éê
RCtl deletion
1
(max. 64)
All deletion
ENT
éê
sicure?
NO=CLR YES=ENT
Expansion addr.
1
(max. 4)
RCtl list
ENT
éê
RCtl list
1
nnnnnnnnnnnnnnnn
RCtl Test
ENT
éê
Sat(n) B(n) TCM(n)
received signal
to following
page
- 44 -
Sat(n) B(n) TCM(n)
received signal
from previous
page
from previous
page
Eeprom deletion
ENT
éê
Satellite via Radio
EPROM CANCELLATION: entering this menu it is possible to cancel at same time all detectors
and remote controls acquired. Once occurred the cancellation, the display will visualize
“executed”.
Note: if a Sat-Web has been already used and is installed in a new system, keyboard visualizes a warning message “ERR:N:” satell.”
(mistake n. 2 radio extension board). To make this board working it is necessary to register it inside the menu “Wireless expans.” or
make an eeprom reset in the menu “Sensor modify”
LABELS: zone, codes, Open Collector
Labels
ENT
éê
Panel string
ENT
éê
Panel string
Zone labels
ENT
Label #
éê
0
(max. 88)
Label# 1
Label 1
User labels
ENT
éê
Label #
Label #
O.C. labels
ENT
éê
Label #
Label #
0
(max. 64)
1
0
(max. 40)
1
Stripes: it is possible to vary the stripes of zones, of the user
codes and of the Open Collector outputs
Central Stripe: there is the possibility to vary the initial stripe
appearing when entering the programming; at factory the stripe is
programmed with AVS ELECTRONICS
Zones Stripes: for any input zone, it is possible to associate a
description of 16 alphanumerical characters; this stripe makes it
easier for the user to identify the zones in which the system is
shared
Users Stripes: for any user code it is possible to associate a
description of 16 alphanumerical characters
Open Collector Stripes: it is possible to associate a description
of 16 alphanumerical characters for Open Collector
ÊPress the arrows (é) and (ê)
Ê Press (CLR) in order to vary
ÊWriting keys:
to select the stripe
(1)abc1(2)def2(3)ghi3(4)jkl4(5)mno5(6)pqr6(7)stu7(8)vwx8(9)yz.
(0)_’0
ÊPress the arrow (ç
ç) and (è
è) to position the slide
Ê Press (ENT) to confirm
Note: the management of various stripes is linked to a maximum
number of characters that can be managed by the control panel; in
order to use this opportunity, it is suggested, for those using the
panel at its maximum configuration; to possibly avoid if the use of
long stripes.
DATE / TIME
Date / Time
ENT
éê
01 / 01 / 03
17 : 10 : 45
Prog. Date/Time: set proper date and hour shown by display of keyboard; in order to
obtain a correct analyse of recorded events in the events memory, it is necessary to have
date and hour properly programmed.
Press on CLR to vary
Press on arrows (é) and (ê) to vary
Press ENT to confirm
PROG. DATE / HOUR
The system is working with a real time clock, synchronised on the 50 Hz from the mains. It
is possible to program the date/time with the arrows buttons.
AUTOTEST
Autotest
ENT
éê
I Autotest Hour
0
(max. 23)
I Autotest Min.
0
(max. 59)
Autotest Interv.
0
(max. 255h)
to following
page
Autotest on Arm
NO
The Autotest, it is a function of dynamic test of the battery of the control panel and of the
additional power supply unit(s) (POWER1B or POWER4B); the microprocessor is controlling
the discharge curve of the relative batteries.
It is done at the programmed hour and can also send a digital communication.
With the programming of the interval, it is settled the moment in which the function of Autotest
will performed.
1° Autotest Hour : Hour Delay from the moment you are in programming up to 1° Autotest
will be done
1° Autotest Min : Minutes Delay from the moment you are in programming up to 1° Autotest
will be done
Autotest Interv. : Moment in which the Autotest will be performed (after the 1°)
Autotest on Arm: In addition to the previous function an Autotest will be performed during
Arming.
Inserting the value 0 (zero) the Autotest won’t performed ever.
NOTE: Each time you are entering in the installer menu, the Autotest function is starting again
from the hour and minutes programmed.
- 45 -
from previous
page
PROGRAMMING TIMER
Watch Program (PO) gives the possibility to manage the automatic arming/disarming of the system
and the activation of the O.C.
Overtime activation
While the keypad buzzer is sounding the arming warning, can be entered an enable USER CODE
followed from the digit “8” to start the overtime period (see “USER CODE Prog./… /Activation overtime).
(Each time is delayed the arming of 1 hour for a maximum of 3 times).
Disarming with installation armed by the Watch
While the control panel has been armed from the watch, it is possible a disarming entering an enable
USER CODE.
Programm. Timer
ENT
éê
éê
Operat. # 1
(max. 40)
• Operation (max 40): select the operation you wish to program;
up to 40 operations can be configured.
Copy from monday
ENT
éê
Operation Hour::
0
(max. 23)
• Operation time: select the time (hour) of operation start
Operation
ENT
• Operation time : select the time (minutes) of the operation
start
Operation Min.:
0
(max. 59)
• Days of the week: it is possible to set in which days of the
week the operation must be repetaed . Setting “No” the operation
will not be executed for the selected day. (l=Monday / m= Tuesday
/ s=Saturday / d=Sunday)
wk days: mtwtfss
yyyyyyy
Operation Type:
No operation
• Type of operation: it is possible to select one of the various
operations available (see list below)
Sector #
0
(max. 4)
O.C.
0
• Partition / OC: select the OC partition of reference
#
(max. 40)
Day
The day of the week is synchronised automatically with the system’s date
Operation (max 40 per day)
The operations that could be activated are the following:
• ON arming
• HOME arming
• AREA arming
• Disarming
• Arming Announce
• The arming Announce can be also linked to the automatic arming of an Open Collector output(s).
• O.C. activation (from 1 to 40)
to following
page
to following
page
- 46 -
from previous
page
From previous
page
Holidays
ENT
éê
Holidays
Holidays # 1
(max. 10)
Holidays Programming
It is possible to program up to 10 annual periods of festivity, during which the panel won’t make programmed function.
Example 1: festivity of only one day, [e.g.] 22/07/99, must
be programmed as follow:
1 -[ 22 07] begin [ 22 07] end
Example 2: festivity that is beginning the 25/04/99 and it
is finishing the 26/04/99 must be programmed as follow:
1 -[ 25 04][ 26 04]
Example 3: festivity that is beginning the 25/12/98 and it
is finishing 06/01/99 must be programmed as follow:
1 -[ 25 12][ 31 12]
2 -[ 01 01][ 06 01]
Example 4: following festivity it is not admitted:
1 -[ 15 12][ 15 01]
Note: it is not important the order in which the festive periods are inserted.
0 00 Begin
00 00 End
Summer/Winter
ENT
éê
0 00 Win >Sun
00 00 Sun > Win
Summer / Winter
In this menu can be entered the date of variation of the SUMMER/WINTER time.
it is also possible this changing using the RTC function.
Example 1:
WINT-> SUM [15 03]: March 15 from the hours 02: 00, the clock is moving to the
hours 03: 00.
SUM -> WINT [15 09]: September 15 from the hours 03: 00, the clock moves to the
hours 02: 00.
Timer option
ENT
éê
Buzzer announce
0 (max. 60 min.)
Buzzer Announcer
Timer options
Buzzer Announce
Before the automatic arming it is possible having a notice from the buzzer(s) of the
programmed keypad(s).
This notice period can be programmed up to a maximum of 60 min..
During this time it will be possible insert the overtime period, inserting an enabled
USER CODE.
Formality of operation
The way of activation of the watch program will follow the “stable” arming modality.
The possibility of disarming from a keypad or from an external device, can be
programmed in the USER CODE menu and also in the Key Function Programming
menu.
PT Reset
ENT
éê
Reset - Progr.Orario
Are you sure?
CLR=NOENT=YES
Confirming the PO RESET, causes the timer to restore to configuration by default
ÊPress (ENT) to restore all default parameters
ÊPress (CLR) to leave
to “Country”
page
- 47 -
from previous
page
PROGRAMMING DIALLER
In this menu, it is possible to memorize up to 8 profiles of 4 telephone numbers, the communication protocol (Vocal, Fast,
Sia, Sia_Hayes, Contact ID) and the number of attempts allowed for each of them, the kind of interface used for sending
them, and whether the general or the area phonetics has to be communicated.
The first step to do is to associate a User ID (identification) to the telephone numbers, in order to give the User
specifications to the telephone number.
The second step to do is to set the optional telephone parameters, which are present in the menu “Telephone Options”
The third step to do is to set which events are enabled to call these numbers:
Alarm Communications: they are enabled by the menu “Lines Association”, associating the input lines communicating the
alarm to any telephone group
Technical Communications: they are enabled by the menu “Events Association”, associating the technical events to be
communicated to any telephone group
Dialler
ENT
éê
see under
Tel. profiles
Tel. profiles
Select the profile (of telephone numbers) from 1 to 8 to be programmed
To page
Country
Tel. profiles
ENT
Telephon profiles- Telephone numbers
éê
Tel. profiles # 0
(max. 8)
Protocol
None
The protocol is, for every telephone number, the kind of transmission format
used for the events.
VOCAL: With the optional board EUROSINT it is possible to communicate to
telephone numbers a vocal message for every event, if programmed.
FAST FORMAT: Ademco 1400 - 2300 Mz, DTMF 10 pps format
SIA HAYES: This digital protocol is used to communicate the alarm and technical
events to a receiver. With WINREC program is possible to set the Zone Codes for
every line.This protocol allows also to download the programming from the control
panel using the Hayes Modem mod.XM40 or enabled AVS Modem and software
WINREC.
SIA: Level II standard protocol. 300 pps FSK Bell 103 .
CONTACT-ID: Ademco 1400 - 2300 DTMF 20 pps extended format.
SMS: it is the protocol allowing to send alarm and technical SMS; it requires the
installation of the optional board GSM Plus and the setting of GSM interface.
Interface
GSM
Interface
POTS
to following
page
To following page
Prof. 1 tel 1
Interface:
Set the interface to which you wish to send the telephone calls
POTS
Select POTS if you wish to send the calls only on the analogical line by use of
LOGICOM
GSM
Select GSM if you wish to send the calls only on the GSM net by use of GSM Plus
POTS/backup GSM
Select POTS/backup GSM if you wish to send the calls on POTS line and use
GSM net only in case of absence of the analogical line. The commutation to
GSM occurs after checking the absence of the line tension and after analysing
the Dial Tone (only if it is set on “Listening to free line on YES”)
POTS + GSM
Select POTS + GSM if you wish to send the call on both analogical line and GSM
net, no matter if the call has been sent or not on the analogical line
Vocal A600
Select Vocal A600 if you wish to send a virtual call on keypad A600Plus in order
to activate the audio communications
Prof. 1 tel 1
Note: setting A600Plus, the following programmation,
*********************
change to: Keyboard events
Zone St. A600
*********************
- 48 -
*********************
from previous
page
Prof. 1 tel 1
*********************
Prof. 1 tel 2
*********************
Prof. 1 tel 3
*********************
Prof. 1 tel 4
*********************
PROGRAMMING DIALLER
Profilo 1 Telephone 1-2-3-4:
Set the telephone number
Press (CLR) to vary
Write the figures of the telephone numer
Press (ENT) to confirmation
The symbols * # and the letters P and W can be set using the arrows (é) and (ê) and
è)
confirming by using the arrow (è
The letter P allows the dialler to “understand” the number placed before as necessary to obtain
the external line, if a telephone exchange is present (e.g.: 9P049W334312); the telephone
number dialled on GSM net, will dial the figures after the letter P
The letter W introduces an interval of three seconds (e.g.: 049W334312); the telephone number
dialled on GSM net, will dial the figures after the letter W
Note: This programming are not visualized with VOCAL A600 interface
Visualized only with vocal interface A600 and only on telephone profile 1
Keyboard events
*********************
Zone St. A600
*********************
To enable events to the keypad
Set the number of the keypad to which you wish to communicate the events associated to the telephone profile:
enables the telephone call to all of them
The control panel makes virtual telephone calls to the programmed keypads
e.g. keypads 1-3-7 enabled
Abil. eventi Tast
137
To enable the zone condition to the keypad
Set the number of the keypad to which you wish to communicate the OPENING of the zones associated to the
telephone profile. E.g. all keypads enabled: Abil. St.zone Tast
Þ
User ID A6000
0
(max. 64)
Note: CHECK Keypads Audio Enabling (end-user)
- dial the user code with attribution Master and enter the menu 1 on the keypad you wish to enable
- scroll the programming steps until reaching Setting A600
- enter the menu and adjust the Audio Volume on one of the possible settings (Mute - Low - Medium - High) by
pushbutton CLR. Note: Mute de-activates the keypad audio for any communication (events and zone condition)
Note: CHECK ZONE CONDITION Keypad Audio Enabling (end-user)
- check the user code with attribution Master and enter the menu 1 on the keypad you wish to enable
- scroll the programming steps until reaching A600 Setting
- enter the menu and set Zone Condition Audio on YES/NO by pushbutton CLR
Emit gen.speech
YES
Emit sect.speech
YES
Attempts number
4
(max 16)
Emittion general speech:
Setting “YES”, the general phonetics, recorded by the installer in phonetics code 154 (Message n.
1), is communicated for this profile of telephone numbers
Emittion sector speech:
Setting “YES”the area phonetics is communicated for this profile of telephone numbers
Attempts number (of tel. profile)
The communication is repeated for the number of times set. Of course, if the communication is
successful, the attempts will not be repeated. With regard to Vocal protocol, the control identifying
the success of a call, is enabled by option “Listen to Answer”. Should the option “Listen to
Answer” be not enabled, the dialler will make as many calls as the attempts set.
If a number of more than 1 “Vocal Repetitions” is set, it is possible to break the cycle of calls by
pressing onto button 3 of the telephone receiving the message, between one message and the
following one, if the telephone number is associated to a User enabled to “Break Telephone
Communication”, or dialling (7) to enter RTC if the telephone number is associated to a User
enabled to “Enable RTC function”.
NOTE: setting “0” attempts no telephone call will occur
User ID tel. 1
0
(max. 64)
User ID tel. 2
0
(max. 64)
User ID tel. 3
0
(max. 64)
User ID tel. 4
0
(max. 64)
User ID Telephon 1 (2 - 3 - 4):
It is possible to assciate the telephone number (1 – 2 – 3 – 4) to a precise User. This association
allows the user called to have the qualifications of the reference profile.
The association of the telephone number to a user, also allows, whether enabled, to enter RTC
on GSM net directly at the recognizing of the incoming number with no request for code.
The commands of call break or of RTC entry, as a consequence of a call from control unit, will be
subordinated to profile qualifications.
Enable RTC Func.
NO
Stop Dialler
NO
- 49 -
Autom.RTC Valid.
YES
from previous
page
Teleph.options
ENT
éê
Telephone options
Dial tone listen
YES
Dial mode
DTMF
Attempts pause
60
(0:255 sec)
Vocal repetition
2
(max. 16)
Answer listening
YES
autoansw.machine
NO
Num.rings answer
0
(max 16)
Enab.RTC byGSM
Not enabled
GSM Autotest int
0 (0..30weeks)
Autot. call .pr. #
1
(max.8)
If the option “Call Autotest Profile”
is enabled, the profile must be
programmed as “GSM” INTERFACE
or “POTS+GSM”.
On the contrary, in order to warn of
the mistake in programming, the
eypad will show “Error Prog.#4”.
Enable A600
ENT
éê
To set the options of the dialler.
Dial Tone Listening :
in dailler there is a circuit for free dial tone survey. This circuit sends the telephone call only
when there is free dial tone.
Dial Mode:
to select the dialling mode between Pulse or DTMF mode.
Answer Listening:
if this function is enabled, the vocal message playback will start only after the answer of
Called User has been detected; in this case, the telephone call is considered as having a
successful conclusion and is repeated no more.
If this function is disabled, the message begins as soon as the dialler has finished to form the
telephone number and the vocal message calls are repeated for all programming attempts.
Autoanswer Machine:
if the Answer Rings Number function is enabled and there is an autoanswering machine
installed, It is possible to bypass it. Operation for accessing logicom in RTC: Call the
installation Logitel 8 Plus, wait for the first ring and hang up immediately; recall after 10 to 20
seconds and the control unit will immediately answer.
Pause Attempts:
this is the pause between 2° and successive attempt s to the same telephone number.
Vocal Repetition:
decide how many times the vocal message must be repeated when a thelephone call is sent.
Number Rings Answer:
enabling this Ring Back function, with a ring number more than 0 (zero) it is possible to call
the installation where the Logitel 8 Plus is positioned to make a check or a remote management.
For the Vocal protocol, the control for a successful conclusion of a call, is enabled using the
parammeter “Answer Listening” as YES. If it is “NO”, the dialler will call the telephone number
for all the programmed “Number Attempts”.
If the option “Vocal Repetition” is greater than 1, it is possible to stop the vocal telephone
communication pressing the push-button [3] on the phone.
Enable RTC by GSM
If this function is enabled, the RTC function can be also made on GSM net, taking care
of the following:
- Only telep.-book: it accepts RTC in GSM only by numbers included in telephone profiles
- Only CLI numbers: it accepts RTC in GSM by all visible numbers
- All tel. numbers: it accepts RTC in GSM by all incoming numbers
Interval GSM autotest
To define after how many weeks a telephone call will be made, in order to test the correct
working of GSM Plus.
This counter refers to the succesful issue of the telephone call and is resetted at anytime if
any telephone call to the settled profile in "profile autotest telephone call" is succesful.
Profile Autotest Telephone Call
To settle from which profile the telephone numbers to call for testing GSM will be used.
The telephone call will be made after the time set in "Interval GSM Autotest"; if the telephone
call is not succesful, it will be repeated the following day at the same time .
Set a profile having "GSM" or "POTS+GSM" as interface.
Take Care: the RTC function is active only for the user’s codes associated to a profile
where this function is enabled (See “Enable RTC fucntion”).
Arming: OHA-D
n Y YY
A600Plus Enabling
In this menu it is possible to enable the keypads to communicate the
events and/or the zones conditions in one of the different modes
of arming/disarming
Abilitazioni A600 Plus
Si fa presente che le chiamate alle
tastiere ritardano le comunicazioni ai
numeri telefonici.
Associate zones
ENT
éê
Tel. profile # 1
(max. 8)
Setting
the keypads are enabled to
communicate only when the area is in HOME or OFF.
If more areas are associated to profile 1 (set as Vocal A600) the
lowest arming/disarming among those activated is considered as
Associate zon 1
nnnnnnnnnn
Associate zone
Associate zon 11
nnnnnnnnnn
Associate Zones
Associate zon 25
nnnnnnnnnnnnnnn
to following
page
Arming: OHA-D
nYn Y
In this menu it is possible to enable the zones to telephone
number.
Associate zon 41
nnnnnnnnnnnnnnn
- 50 -
from previous
page
Event to dial
Event to dial
ENT
éê
Com. Tamper 1
Prof..: nnnnnnnn
Zone bypass
1
Prof..: nnnnnnnn
ON Arming
1
Prof..: nnnnnnnn
HOME arming 1
Prof..: nnnnnnnn
AREA Arming 1
Prof..: nnnnnnnn
Mains fault
1
Prof..: nnnnnnnn
Low battery
1
Prof..: nnnnnnnn
Watch-Dog
1
Prof..: nnnnnnnn
Com. Codes 1
Prof..: nnnnnnnn
Emerg. codes 1
Prof..: nnnnnnnn
Autotest
1
Prof..: nnnnnnnn
Com. Panic
1
Prof..: nnnnnnnn
Com. Medic
1
Prof..: nnnnnnnn
Com. Fire
1
Prof..: nnnnnnnn
Fire zone
1
Prof..: nnnnnnnn
us. / key. false 1
Prof..: nnnnnnnn
Interference
1
Prof..: nnnnnnnn
Survival loss
1
Prof..: nnnnnnnn
In this menu it is possible to associate these events to every programmed telephone number for
digital or vocal protocol communications.
Communication of TAMPER:
it communicates the tampering alarm of dedicated input line and keypads to the selected telephone
numbers if this event happens,.
Communication of ZONE BYPASS (no fast):
it communicates the Zone Bypass by User Code or by automatic exclusion to the associated
telephone numbers.
Communication of ON ARMING:
it communicates arming / disarming in ON modality to the associated telephone numbers.
Communication of HOME ARMING:
it communicates arming / disarming in HOME modality to the associated telephone numbers.
Communication of AREA ARMING:
it communicates arming / disarming in AREA modality to the associated telephone numbers.
Communication of MAINS FAULT:
it communicates the Mains Fault the associated telephone numbers, after the delay set out.
Communication of LOW BATTERY:
it communicates Low Battery to the associated telephone numbers.
Communication of WATCH-DOG:
Watch-Dog is a particular failure recovery event on microprocessor; if there are strong electric
disturbances (thunderbolts, mains transients, ...) this circuit restarts the system without the loss of
any memorized data, communicating this event to the associated telephone numbers.
Communication of CODES (no fast):
it communicates the dialled User Code, which is associated with the function “Code Communication”, to telephone numbers
Communication of EMERGENCY CODES (no fast):
it communicates the digited Emergency User Code, associated with the function “Comm.Emergency
Code”, to telephone numbers
Communication of AUTOTEST:
it communicates the selftest to the associated telephone numbers that can be used to send a
periodic supervisory communication of the system.
Communication of PANIC Message (no fast):
the pressing the push-buttons (1) and (CLR), at the same time, activates a direct communication to
the associated telephone numbers.
Communication of MEDICAL Message (no fast):
the pressing of push-buttons (3) and (CLR), at the same time, activates a direct communication to
the associated telephone numbers.
Communication of FIRE Message (no fast):
the pressing of push-buttons (2) and (CLR), at the same time, activates a direct communication to
associated telephone numbers.
Communication of Fire alarm:
it communicates the fire alarm, associated with function “Com. Fire”, to telephone number.
Communication of User / key false (no fast):
it communicates the User / key false, associated with function “Us/Key false”, to telephone number
Communication of Interference (no fast):
it communicates the radio interference, associated with function “Interference”, to telephone number
(SAT W)
Communication of Survival loss (no fast):
it communicates the radio Survival loss, associated with function “Survival loss”, to telephone
number (SAT W)
Communication of Prealarm (No Fast)
Communication of zones’ pre-alarm, if “pre-alarm memory” is set to YES in Zone Options
Communication of GSM events (No Fast)
It communicates the low credit of Sim Card and, whether set, it also enables the call for the Sim
Inactivity
Note: “No Fast” shows the events that are not communicated in Fast protocol.
Prealarm
1
Prof..: nnnnnnnn
GSM events
1
Prof. : nnnnnnnn
Associate sector
ENT
éê
to following
page
Sector
#
1
(max. 4)
Associate sector
Sect. 1
1
Prof.:YYYYYYYY
Acc. code pr.
000000
1
Acc. code pr.
000000
8
Associate Sectors (partitions)
In this menu it is possible to enable the sectors (partitions) to
telephone profilres and to set the Account Code (Client Code).
Account code profile
(Client Code) is associated to every communicated event to
identify the customer.
• In SIA and SIA_HAYES it is of 6 digits;
• In SEIA, Fast Format and CONTACT DI it is of 4 digits;
Example : Account code in SIA : 123456 / Account code in
SEIA: 1234**
- 51 -
from previous
page
Zone parameters
ENT
éê
Zone parameters
Zone Nr.:
(max. 88)
0
FAST Chanel 1
3
(max. 8)
SIA Code
1
1
(max. 13)
SIA Codes
The codes to input go from 1 to 13.
The remote computer, with activated mod.WINREC programme , which is
connected using modem mod.AVS-XM40 is abled to recognize this code
togheter with other parameters, that dialler sends, to identify the installation
and the type of alarm signal.
Codification SIA line (1..13)also for vocal message: (1 default management)
SIA allottable codes are:
• Cod. 1: BURGLAR
• Cod. 2: GAS
• Cod. 3: GENERIC
• Cod. 4: FIRE
• Cod. 5: HEAT
• Cod. 6: MEDICAL
• Cod. 7: PANIC
• Cod. 8: EMERGENCY
• Cod. 9: IRRIGATION
• Cod. 10: WATER LEVEL
• Cod. 11: COLD
• Cod. 12: TAMPER
• Cod. 13: ROBBERY
For each input line, the control unit is abled to recognize and to send automatically
4 differents states:
• a) ALLARM
• b) RESTORATION
• c) EXCLUDED LINE from OFF ZONE
• d) INCLUDED LINE from OFF ZONE
Changing this codification changes the type of digital and vocal
Comunicazioni automatiche zone
Says alarm/rest.
YES
Says zone code
YES
Says zone speech
YES
Says zone number
YES
Send. SMS strip
YES
Vocal word 1
0
(max. 255)
Vocal word
2
0
(max. 255)
Vocal word
3
0
(max. 255)
Vocal word
4
0
(max. 255)
Say alarm / restore
Setting “YES” the word ALARM or RESTORE will be communicated
Say zone code
Setting “YES” the word included into “SIA codification” will be communicated
Say zone speech
Setting “YES”, the word ZONE will be communicated
Say zone number
Setting “YES” the ZONE NUMBER will be communicated
Sending zone strip on SMS
Sending SMS strip
Setting “SI” the associated zone strip is used
Zones’ Personalized Communications
Introducing a value different from zero (0) in the programming steps “Vocal
word 1 - 2 - 3 – 4”, it is possible to personalize the vocal alarm
communication of the control unit with max 4 personalized words (see
phonetics chart)
Vocal word 1
Setting a number value different from “0”, the control unit
the word associated to the value (see phonetics chart)
Vocal word 2
Setting a number value different from “0”, the control unit
the word associated to the value (see phonetics chart)
Vocal word 3
Setting a number value different from “0”, the control unit
the word associated to the value (see phonetics chart)
Vocal word 4
Setting a number value different from “0”, the control unit
- 52 -
will communicate
will communicate
will communicate
will communicate
from previous
page
Fast Chanel
FAST Chanels
ENT
éê
FAST arm/disarm
2
(max. 8)
FAST Chanel
programming this chanel, which are usually used for Monitoring Centers and,
according with them, it is possible to change the encoding.
FAST tamper
1
(max. 8)
FAST watch-dog
3
(max. 8)
FAST mauns fault
4
(max. 8)
Fast Chanel TAMPER (1..8) : tampering
Fast Chanel ARMING (1..8) : arming and turning off
Fast Chanel WATCH-DOG (1..8) : system restart
Fast Chanel MAINS FAULT (1..8) : mains fault and restoration
Fast Chanel Line 1..8 (1..8) : line alarm
FAST fire
5
(max. 8)
Remote handling
ENT
éê
Tel. Num.#
*********************
Account code
000000
Protocol
SIA_HAYES
Remote handling
Telephone Number : the “Remote Handling” telephone number is reserved to
installer for the following uses:
a.
to communicate the Event Memory Dump from the control panel
b.
to download the control panel programming
to communicate every alarm or technical Event that is programmed to be
communicated to the receiver station use one of the 8 telephone number,
Account code: (Client Code) is associated to communication to identify the
customer.
Protocol: to select the kind of transmission format used for the events. (SIA /
SIA_HAYES)
Vocal message Play Rec
mess. Play Rec
ENT
éê
Voc. msg # 154
(max.178)
Playback
Record
ENT
MEM
Playback/Record
****=======
Play Rec messaggi:
Messaggio Vocale n°??: it is necessary to select the message to record.. By use of
the arrows (é)/(ê) select the message to record; press ENT to confirm
Playback ENT: press ENT to listen to the message
Record MEM: press MEM to record
Stop Record ESC: Press ESC to break the recording
PS only the message 154 has 10 seconds recording, the others have max
from 0,8 to 2 seconds
- 53 -
From page
Prog.Dialler
Country
ENT
éê
COUNTRY
It makes the control unit fitting local electrical/behaving standards
LANGUAGE
Language
ENT
éê
Lingua/Language
Press CLR...
Lingua/Language
Italiano
It adapts the control unit to the local language.
DOWNLOADING
During language updating, the display on the keypad will showÞÞÞÞÞÞÞÞÞ
The completing of the procedure is visualized by the running DOWNLOADING
===ÞÞÞÞÞÞ
of the symbol “=”.
EVENTS MEMORY
Events Memory
ENT
éê
Sectors: 1 2 3 4 +
Status:
1° 09 : 22 15 / 09
Installer code
All the events that have been programmed in order to be recorded in the memory
events can be displayed on the LCD of the keypad. The panel can show 250
events with date and time.
Entering in the Memory Events Menu there is the possibility to analyze what has
happened from the last event, that is that most recent one, to the oldest one.
2° 09 : 10 15 / 09
EEPROM Reset
EEPROM Reset
ENT
éê
Are you sure..??
CLR=NOENT=YES
The confirmation of EEPROM RESET causes the reset of the entire configurationof the
control unit, putting it back to the “factory” values, Events memory excluded
Press on ENT to reset all default parameters
Press on CLR to exit
Test of zones
Zone walk test
ENT
éê
Zone Nr: MEMO
YYYYYYYYYY
The test function of the zones allows to visualize the status of all the zones of the
control panel.
• key (5), allows to activate or not the memory function, in addition entering
and exiting from the MEMO function, it is possible to obtain the cancellation of
the previous memorization.
key (CLR), allows to the escape from the function Test of the Zones.
keys arrow (é) and (ê) allow the selection of the group of zones to visualize.
function (MEMO) signals that the memorization modality is active, and so the
opening of one or more zones provokes the relative memorization
to following
page
- 54 -
From page
precedente
Menù standby
ENT
éê
MENU’ STANDBY
Rem time: (min.)
60
Entering in this modality, you will obtain the block of all alarm signalling for a
period of 60 minutes; in such way it is possible make a more simple
maintenance service of thesystem.
The timer can be restored to 60 minutes, simply exiting and entering in the
menu, or pressing any key.
EPROM VERSION
EPROM version
ENT
éê
Eprom Version
V x.xx
Visualization of the version and date of the EPROM of the control panel.
Note: The software version of the keypad, comes visualized pressing simultaneously keys (CLR) and (ESC).
End of programming and return to "Installation" menu
Codes Reset
In case the INSTALLER CODE got lost, it is possible restart with the default code, following this procedure on the control
panel board:
1. close and maintain closed (jumper S1) near to the RESET push-button.
2. press and release the Reset push-button.
3. after approximately 12 seconds the alarm relay will be activated; as soon as active, open (bridge S1).
4. the alarm relay will be automatically disabled after approximately 2 seconds.
5. now the INSTALLER CODE is back to the default one (value 000000). All the arming and telephone calls are resetted.
IMPORTANT ANNOTATION!
The following parameters
INSTALLER CODE:
Keypad:
Satellites:
Key ser. device
will return to the default values:
000000
1
0
0
- 55 -
STATEMENT OF CONFORMITY TO THE R&TTE 99/05/CE DIRECTIVES
- 56 -
List of the products of the ADVANCE88 system and their Certifications
C ategory
K eyp ad s
Satellites
Modello
C ertfication
A 600
IMQ
A600Plus
IMQ
A 300
IMQ
A300Plus
IMQ
Keyplus
IMQ
SAT03
IMQ
SAT04
IMQ
SATWS
XSAT8
XSAT2
XSAT36
Extension w ith
additional
supply unit
Extension w ith
additional
supply unit
board
XSATPW3Q
Telephone
D iallers
LOGIC OM
IMQ
GSM Plus
IMQ
XSATPS5Q
XSATPW3
XSATPW5
RK32
RK32SR
IMP32
K eys
EB1
E B 1S R
EB3
RS .. (lettore seri ale)
POWER1Q
Additional
Supply units
POWER4Q
POWER3Q
POWER5Q
POWER1
Additional
supply units
board
POWER4
POWER3
POWER5
Accessories
Modem
EXPEURO
IMQ
MR4
IMQ
MR8
IMQ
EUROSINT88
IMQ
AD VOIC E
IMQ
XM40
XM40Plus
C onverter
X S 40
X S 40U
Sw tele
management
WINREC
- 57 -
- 58 -
- 59 -
AVS ELECTR
ONICS S
.p
.A.
ELECTRONICS
S.p
.p.A
Via Valsugana, 63
35010 (Padova) ITALY
Tel. 049 9698 411 / Fax. 049 9698 407
[email protected]
www.avselectronics.com
Assistenza Tecnica: 049 9698 444
[email protected]
- 60 -