User manual | BPT MNA/102LR Modular Keypad Quick Start Instructions

User manual | BPT MNA/102LR Modular Keypad Quick Start Instructions

The BPT MNA/102LR Modular Keypad is a versatile access control device with multiple features for door management. It allows up to 100 user codes to be assigned for door access, and offers customizable configurations to meet your specific security needs.

advertisement

BPT  MNA/102LR Quick Start Instructions | Manualzz

RTE. DOOR 1

ONLY

N/O. PUSH SWT

ELECTRICAL SPECIFICATION

SUPPLY VOLTAGE - 12-24 volts. AC or DC

CONSUMPTION - 220mA max

IF TELEPHONE TWISTED PAIR TYPE CABLE

IS USED, LINES +/- TO THE KEYPAD

SHOULD CONSIST OF A PAIR FOR BOTH

DOOR 2

RELAY CONTACT RATING

2 Amp. Max at 24v AC/DC

DOOR 1

NOT USED

NOT USED

NORMALLY OPEN

NORMALLY CLOSED

COMMON 2

NORMALLY OPEN

NORMALLY CLOSED

COMMON 1

I1

L

L

NO

NC

C2

NO

NC

C1

MODULE

MNA/102LR

FEATURES

* UP TO 100 USER DOOR OPEN CODES

* USER CODES MAY BE 3-4 OR 5 DIGITS

* PROGRAMMABLE 5 DIGIT MASTER CODE

* SPECIAL CODE IN THE EVENT OF LOSS OF MASTER

* PENALTY LOCK OUT AFTER REPEATED CODE ATTEMPTS

* TIMED OR LATCHED OUTPUTS TO DOOR 1 & 2 RELAYS

* REQUEST TO EXIT INPUT (DOOR 1 ONLY)

* 1 OR 2 DOOR CONTROL

* DURESS ALARM

* VISITOR DOOR BELL FEATURE

SEE NOTE BELOW

NOTE:

THE DURESS AND VISITOR DOOR BELL FUNCTIONS

CANNOT BE USED IF THE KEYPAD IS PROGRAMMED

FOR 2 DOOR CONTROL.

CONSULT THE FULL INSTRUCTION DETAILS FOR

PROGRAMMING OF THESE 2 EVENTS IF REQUIRED.

SPECIAL NOTES:

WHEN USING THE KEYPAD IN A STANDLAONE MODE ie. NOT

CONNECTED TO A BPT AUDIO OR VIDEO SYSTEM POWER

SUPPLY.THE ELECTRICAL SPECIFICATION MUST BE

ADHERED TO.

WHERE DOOR RELEASES ARE BEING SWITCHED DIRECTLY

VIA THE KEYPAD RELAY CONTACTS, THE DOOR RELEASE

MUST HAVE A SUPPRESSION DEVICE FITTED ACROSS

THE SUPPLY LINES CLOSE TO THE RELEASE ITSELF.

THIS PARTICULARY RELATES TO MAGLOCKS AND IDEALLY

THE SUPPRESSOR SHOULD BE A 'mov' (metal oxide varistor)

OR DIODE IF'mov' IS NOT AVAILABLE.

DAMAGE MAY OCCUR TO THE ON-BOARD

ELECTRONICS IN THE EVENT THAT SUCH

SUPPRESSION IS NOT FITTED.

BPT (UK) LTD.

HERTS. ENGLAND

DRAWING TITLE:

PREPARED FOR

INSTALLATION ENGINEERS

MODULAR KEYPAD SPECIFICATION

DATE: 04/08/98

REVISED: 11/10/01

DRAWING No: MNA.

DRAWN: KR

PROGRAMMABLE FUNCTIONS INSTALLERS & USERS

Important Note: Unless the function is altered (see 07 below) the number of digits allowed for all

User codes is 4. if you require any of your User codes to be 3 or 5 digits long, then function 07 must be set first. Be aware that this will now apply to all User codes, except the Master / Engineer code

which will always be 5 digits.

PRE-SET DEFAULTS

Master Code

Code Length

Door 1 Code

Door 2 Code

Door Open Time

Penalty Time

Visitor Key *

Duress output

Relay Mode

ENTERING PROGRAM MODE

12345 - preceded by 1 & 7 pressed simultaneously

4 digits

2580

3690

5 seconds

10 seconds

Disabled

Disabled

Monostable

If the Master Code has been changed from the Default of 12345 and is not known, for security purposes you will not be able to enter into the Program Mode. Consult Bpt. with the keypad serial number obtained from the label at side of module MNA/102 LR in this event.

During any of the procedures detailed below, if you inadvertently enter an incorrect digit, simply press * key. This will return you to a point to start the function again - select 01 - to - 13. Be aware that you are still in Program Mode -

Green LED flashing, enter 99 to exit if desired.

ONCE POWERED UP, PRESS KEYS 1 & 7 SIMULTANEOUSLY - LONG TONE MUST BE HEARD. THEN

ENTER THE KNOWN MASTER 5 DIGIT CODE. TOP GREEN LED SHOULD BE PULSING.

ENTER THE FUNCTION CODE (SHOWN AS (01) TO (13) BELOW) TO CHANGE THE DESIRED DATA.

Change Master Code (01)

Enter - 01

Enter - xxxx (new 5 digit code)

Enter - 99 to exit or enter another function code

Delete All User Codes (04)

Enter - 04

Enter - 0

Enter - 99 to exit or enter another function code

Code Length (07)

(3 - 4 or 5 digits)

Enter - 07

Enter - 3 or 4 or 5

Enter - 99 to exit or enter another function code

Add User Code (02) Delete User Code (03)

Enter - 02 Enter - 03

Enter - 1 or 2 (Door relay req.) Enter - xxxx (code for deletion)

Enter - xxxx (new 4 digit code) Enter - 99 to exit or enter

Enter - 99 to exit or enter another function code another function code

Door Open Time (05) Keypad Penalty Time (06)

Enter - 05 Enter - 06

Enter - 1 or 2 (Door relay req.) Enter - 01 - 65 (seconds)

Enter - 01 - 65 (seconds)

Enter - 99 to exit or enter another function code

Relay Mode (08)

(mono or bistable)

Enter - 99 to exit or enter another function code

Enable / Disable Duress Alarm (09)

Enter - 08 Enter - 09

Enter - 1 or 2 (Door relay req.) Enter - 0 - Disable

Enter - 0 - Bistable

or - 1 - Monostable

Enter - 99 to exit or enter another function code

or - 1 - Enable

Enter - 99 to exit or enter another function code

Enable / Disable Bell (10)

Enter - 10

Enter - 0 - Disable

or - 1 - Enable

Enter - 99 to exit or enter another function code

Alarm Reset (13)

Enter 13

Enter - 99 to exit or enter another function code

EXPLANATION OF FUNCTIONS

Enable / Disable RTE (11)

Enter - 11

Enter - 0 - Disable

or - 1 - Enable

Enter - 99 to exit or enter another function code

Special Code

Enable / Disable Keypad (12)

Enter - 12

Enter - 0 - Disable

or - 1 - Enable

Enter - 99 to exit or enter another function code

You must obtain this code from Bpt. UK. (serial No. req.).

Enter 3 & 9 absolutely simultaneously. Long tone heard.

Enter the special code from Bpt.

Master Code is reset to default 12345 allowing entry into Programme Mode.

KEYPAD TONES:- The keypad will emit long and short tone bursts to indicate correct or incorrect data strings entered during programming. At end of modifying data during any function, if the entry was correct a long tone will be heard, if incorrect three short tones will be heard.

At long tone, you may simply exit program mode by entering 99 or enter another function code.

At 3 short tones, you will automatically be returned to ‘in program mode’ status, simply start the function again.

06 - KEYPAD PENALTY TIME:- The Keypad will lock out for this time period, if after 20 key inputs, any correct User code has not been entered. This has the benefit of being able to hide the 4 digit code among a string of 16 other inputs, preventing onlookers from obtaining the code if entered as only 4 inputs, (as occurs with Bank ATM’s etc.).

08 - RELAY MODE:- The relay output mode for Door 1 & 2 is pre - set to monostable, that is will energise and deenergise after the set time. The bistable setting will alter the relay mode such that a code input will energise it and it will stay energised, entering any User code thereafter assigned to that relay 1 or 2 will de-energise it.

09 - DURESS ALARM:- When set to Enabled, if a User enters * before his code, relay 1 will energise to release the door, also relay 2 will energise and can be used to signal an alarm, alerting others to door opened under duress. Note that this function can only be used if relay 2 is not in use as a 2nd door opener or for Visitor Bell function.

10 - VISITOR BELL:- When set to Enabled, if the Visitor presses * key, then relay 2 will energise for 3 seconds, enabling interface to a bell or buzzer. See note at end of Duress above.

11 - RTE INHIBIT:- When set to Disabled, any RTE push button connected is prevented from operating. The default is set for Enabled.

12 - KEYPAD INHIBIT:- When set to Disabled, the keypad is prevented from Door opening when user codes are entered. This function may be used for weekend prevention of entry for instance.

13 - ALARM RESET:- This function code must be entered whenever function 09 is used in conjunction with relay 2 output. The relay will latch into Alarm on Duress code entry, function 13 will reset the Alarm State.

ADDITIONAL USEFUL FUNCTION - (WHEN IN NORMAL OPERATING MODE)

Whenever a User Code is entered, if the # key is pressed prior to Door release time ceasing, the relevant Door relay 1 or 2 will be held energised. Entering the code at any later stage will de-energise the relay. This function is useful for automatic gates / barriers etc. where continuous open state may be required for any period during the day. Users should be aware that the function may be used with DC. continuously rated strikes, but not with AC devices.

‘VERY QUICK’ START INSTRUCTIONS

The following instructions relate to Keypad supplied from new only.

The Keypad enables up to 100 user codes to be assigned to open Door 1 or 2.

At time of first installation, 2 codes are already pre-assigned for this purpose, additionally a Master/Engineer code is assigned.

If you simply wish to change these pre-assigned codes to your users preferred codes, follow strictly as set out below.

NOTE:

WHEN USING A 5 DIGIT CODE - THE MAXIMUM USEABLE No. IS 65535, THUS YOU CANNOT USE eg. 98765 or 99999 etc.

Once powered up, Press Keys 1 & 7 Absolutely Simultaneously -

A long tone must be heard. Then enter Master code 12345

Top Green Led should now be Pulsing. currently 2580

To change this:

Enter - 03

Enter - 2580

Enter - 02

Enter - 1

Enter - xxxx (new code)

Enter - 99

New code must be 4 digits only

Door 2 Code is currently 3690

To change this:

Enter - 03

Enter - 3690

Enter - 02

Enter - 2

Enter - xxxx (new code)

Enter - 99

New code must be 4 digits only

Master Code is

Currently 12345

To change this:

Enter - 01

Enter - xxxxx (new code)

Enter - 99

New Code must be 5 digits only and cannot exceed 65535.

Always use this new Master code to enter the Engineer programming mode.

If you input a digit in the wrong place or get lost in the programming, we suggest you enter 99 three times. This should exit you from the program mode (Green LED not pulsing). Start again from 1 & 7 simultaneously.

If the long tone is heard after 1 & 7, but 12345 does not start the Green LED pulsing, this suggests the Master Code 12345 has been changed.

Consult Bpt. on: 01442 230800 Tech. Support.

advertisement

Key Features

  • Up to 100 user codes
  • Programmable master code
  • Timed or latched outputs
  • Duress alarm feature
  • Visitor door bell feature
  • Request-to-exit input
  • 1 or 2 door control
  • Penalty lockout after repeated code attempts

Frequently Answers and Questions

How many user codes can I program into the keypad?
The keypad can store up to 100 user codes.
What is the default master code?
The default master code is 12345. However, you can change this to a 5-digit code of your choosing.
What is the purpose of the Duress Alarm feature?
The Duress Alarm feature allows a user to signal an alarm if they feel threatened. If a user enters * before their code, it will energize a relay that can be used to trigger an alarm.
Can the keypad be used for both doors, or only one?
The keypad can be configured for either 1 door or 2 door control.
What is the meaning of 'Monostable' and 'Bistable' modes for the relays?
The relays can operate in Monostable or Bistable modes. In Monostable mode, the relay energizes and de-energizes after a set time. In Bistable mode, the relay remains energized until a code is entered to de-energize it.

Related manuals

Download PDF

advertisement