Controllers and repeaters X X Controllers 6.2 – and repeaterstestregistrierung TROXNETCOM AS-i Controllers and repeaters Controllers for the data acquisition and control of the field modules, repeaters for a maximum expansion of the network Controller for controlling actuators and for monitoring the damper blade position and duct smoke detectors ■ Controller with TROXNETCOM Basic User Software ■ Easy and safe commissioning without programming ■ Controller with master function for stand-alone operation 6 ■ System monitoring ■ Automatic recognition of components and their status ■ Menu-driven user interface (controller display) for system configuration ■ Peripheral equipment can be tested without additional auxiliary equipment 06/2015 – DE/en K4 – 6.2 – 1 TROXNETCOM AS-i General information Controllers and repeaters Type Page Controllers and repeaters Description TROXNETCOM AS-i Controllers and repeaters 6 General information Special information – TNC-A1305 Special information – TNC-A1306 Special information – TNC-A1353 Special information – TNC-A1354 Special information – TNC-A1375 Special information – TNC-A2225 Special information – TNC-A003S Special information – TNC-ZB0252 Special information – TNC-Z0119 6.2 – 2 6.2 – 3 6.2 – 5 6.2 – 7 6.2 – 9 6.2 – 11 6.2 – 13 6.2 – 15 6.2 – 17 6.2 – 19 Basic information and nomenclature 6.4 – 1 Application Controller – Controllers (AS-i masters) are basically used for management functions. – They initialise the AS-Interface network, recognise all slaves on a bus, perform error diagnosis, and send signals. – They also control the data transfer on the bus and request status information from all slaves in regular intervals. – The data for all slaves is stored in the controller – A single controller can manage 31 slaves, a dual controller can manage 62 slaves – Controllers provide interfaces (gateway functions) to higher-level central units or controls, e.g. PROFIBUS DP and Ethernet – Controllers can be linked through these interfaces and hence allow for building independent systems without a central unit – The programming effort for the central unit is fairly low since the data in the controller have already been pre-processed – The AS-Interface controller is treated as a slave of the higher-level system – AS-Interface does not incur the cost for programming the gateway function, which is usually required for other systemserface – This is handled by the dedicated TNC Basic User Software – Each controller with master function is equipped with this software Repeater – AS-i repeaters are used to extend the usual length of AS-i networks by another 100 m – An existing 100 m segment can be extended by another 100 m – Two repeaters can be used on one AS-i segment, i.e. one segment can be up to 300 m long – The total number of 31 slaves per controller cannot be exceeded – A repeater acts also as galvanic isolation of the two AS-i segments, hence providing safety against short circuits – Active slaves can be positioned before and after the repeater – Each repeater requires an AS-i power supply unit Order code TNC – A1305 ݇ Type TNC-A1305 TNC-A1306 TNC-A1353 TNC-A1354 TNC-A1375 TNC-A2225 TNC-ZB0252 TNC-Z0119 TNC-A1146 K4 – 6.2 – 2 Controller with PROFIBUS DP interface; 1 master Controller with PROFIBUS DP interface; 2 masters Controller with Modbus/TCP interface; 1 master Controller with Modbus/TCP interface; 2 masters Gateway with PROFIBUS DP interface; 1 master Repeater AS-i safety gateway Passive bus termination AS-i tuner (diagnosis module) 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-A1305 Description Controllers and repeaters Application – AS-i controller TNC-A1305 with 1 master for 31 AS-i slaves – Decentralised operating and monitoring system with signal preprocessing and gateway – With TNC Basic User Software – Recognition of all slaves on a bus – For initialising the AS interface network – Error diagnosis and signalling – LC display, 43 × 28 mm, also for operation – PROFIBUS DP interface TNC-A1305 Technical data Description TNC-A1305 Supply voltage Current consumption Power consumption Programming interface Data interface Diagnosis via PROFIBUS DP PLC memory for user program Display Max. acceptable rel. humidity Status LED Ambient temperature Storage temperature IP protection level MTTF AS-i profile AS-i certificate Casing materials Casing dimensions Fixing Wiring 24 V DC < 500 mA < 10 VA RS232C: RJ11; 9600 – 115200 Bd, galvanically isolated PROFIBUS DP (EN 50170); max. 12 MBd slave Yes 128 Kwords Graphic LC display 128 × 64 pixels, 43 × 28 mm < 95 % 2 × red; 2 x green; 2 × yellow 0 – 60 °C –20 to 70 °C IP 20 5 years M3 61103 Aluminium, galvanised sheet steel 124 × 97 × 86 mm On DIN mounting rail Connecting cable core identification TNC-A1305 n.c. n.c. AS-i 1+ AS-i ʸ̋ 6 FE +24V 0V TNC-A1305 06/2015 – DE/en K4 – 6.2 – 3 TROXNETCOM AS-i Special information – TNC-A1305 62 86 Specification text 6 K4 – 6.2 – 4 4 131 AS-i controller TNC-A1305 124 Dimensions Controllers and repeaters 97 107 Standard description (characteristics) AS-i controller TNC-A1305 (1 master) is a compact AS-i master system with integral text/graphic display and PROFIBUS DP interface. – Control of components as part of fire damper control Integral TNC Basic User Software with the following functions: – Automatic recognition of TROX modules and their functions – Automatic grouping – Network control – Automatic function test – Manual control of dampers – Integral display, also for operation – Simple, menu-driven configuration and adjustment – Supply voltage: 24 V DC – Total current consumption from AS-i: < 10 mA – Casing materials: Aluminium, galvanised sheet steel – Ambient temperature: 0 – 60 C° – IP protection level: IP 20 – Status display: LEDs, 2 x red, 2 x green, 2 x yellow – Make: TROX GmbH or equivalent – Type: TNC-A1305 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-A1306 Description Controllers and repeaters Application – AS-i c TNC-A1306 with 2 masters for 62 AS-i slaves – Decentralised operating and monitoring system with signal preprocessing and gateway – With TNC Basic User Software – Recognition of all slaves on a bus – For initialising the AS interface network – Error diagnosis and signalling – LC display, 43 × 28 mm, also for operation – PROFIBUS DP interface TNC-A1306 Technical data Description TNC-A1306 Supply voltage Current consumption Power consumption Programming interface Data interface Diagnosis via PROFIBUS DP PLC memory for user program Display Max. acceptable rel. humidity Status LED Ambient temperature Storage temperature IP protection level MTTF AS-i profile AS-i certificate Casing materials Casing dimensions Fixing Wiring 24 V DC < 500 mA < 10 VA RS232C: RJ11; 9600 – 115200 Bd, galvanically isolated PROFIBUS DP (EN 50170); max. 12 MBd slave Yes 128 Kwords Graphic LC display 128 × 64 pixels, 43 × 28 mm < 95 % 3 × red; 3 x green; 3 × yellow 0 – 60 °C –20 to 70 °C IP 20 5.19 years M3 61104 Aluminium, galvanised sheet steel 124 × 97 × 86 mm On DIN mounting rail Connecting cable core identification TNC-A1306 AS-i 2+ AS-i ʹ̋ AS-i 1+ AS-i ʸ̋ 6 FE +24V 0V TNC-A1306 06/2015 – DE/en K4 – 6.2 – 5 TROXNETCOM AS-i Special information – TNC-A1306 62 86 Specification text 6 K4 – 6.2 – 6 4 131 AS-i controller TNC-A1306 124 Dimensions Controllers and repeaters 97 107 Standard description (characteristics) AS-i controller TNC-A1306 (2 masters) is a compact AS-i master system with integral text/graphic display and PROFIBUS DP interface. – Control of components as part of fire damper control Integral TNC Basic User Software with the following functions: – Automatic recognition of TROX modules and their functions – Automatic grouping – Network control – Automatic function test – Manual control of dampers – Integral display, also for operation – Simple, menu-driven configuration and adjustment – Supply voltage: 24 V DC – Total current consumption from AS-i: < 10 mA – Casing materials: Aluminium, galvanised sheet steel – Ambient temperature: 0 – 60 C° – IP protection level: IP 20 – Status display: LEDs, 3 x red, 3 x green, 3 x yellow – Make: TROX GmbH or equivalent – Type: TNC-A1306 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-A1353 Description Controllers and repeaters Application – AS-i c TNC-A1353 with 1 master for 31 AS-i slaves – Decentralised operating and monitoring system with signal preprocessing and gateway – With TNC Basic User Software – Recognition of all slaves on a bus – For initialising the AS interface network – Error diagnosis and signalling – LC display, 43 × 28 mm, also for operation – Ethernet – Modbus/TCP interface TNC-A1353 Technical data Description TNC-A1353 Supply voltage Current consumption Power consumption 24 V DC < 400 mA < 10 VA RS232C: RJ11; 9600 – 115200 Bd, galvanically isolated Ethernet CAA, RJ45; 10/100 MBd Modbus/TCP Yes 128 Kwords Graphic LC display 128 × 64 pixels, 43 × 28 mm < 95 % 1 × red; 2 x green; 3 × yellow 0 – 60 °C –20 to 70 °C IP 20 5.2 years M3 In preparation Aluminium, galvanised sheet steel 124 × 97 × 86 mm On DIN mounting rail Programming interface Data interface Diagnosis via PROFIBUS DP PLC memory for user program Display Max. acceptable rel. humidity Status LED Ambient temperature Storage temperature IP protection level MTTF AS-i profile AS-i certificate Casing materials Casing dimensions Fixing Wiring Connecting cable core identification TNC-A1353 n.c. n.c. AS-i 1+ AS-i ʸ̋ 6 FE +24V 0V TNC-A1353 06/2015 – DE/en K4 – 6.2 – 7 TROXNETCOM AS-i Special information – TNC-A1353 62 86 Specification text 6 K4 – 6.2 – 8 4 124 AS-i controller TNC-A1353 131 Dimensions Controllers and repeaters 97 107 Standard description (characteristics) AS-i controller TNC-A1353 (1 master) is a compact AS-i master system with integral text/graphic display and Ethernet interface. (Modbus TCP) – Control of components as part of fire damper control Integral TNC Basic User Software with the following functions: – Automatic recognition of TROX modules and their functions – Automatic grouping – Network control – Automatic function test – Manual control of dampers – Integral display, also for operation – Simple, menu-driven configuration and adjustment – Supply voltage: 24 V DC – Total current consumption from AS-i: < 10 mA – Casing materials: Aluminium, galvanised sheet steel – Ambient temperature: 0 – 60 C° – IP protection level: IP 20 – Status display: LEDs, 1 x red, 2 x green, 3 x yellow – Make: TROX GmbH or equivalent – Type: TNC-A1353 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-A1354 Description Controllers and repeaters Application – AS-i controller TNC-A1354 with 2 masters for 62 AS-i slaves – Decentralised operating and monitoring system with signal preprocessing and gateway – With TNC Basic User Software – Recognition of all slaves on a bus – For initialising the AS interface network – Error diagnosis and signalling – LC display, 43 × 28 mm, also for operation – Ethernet – Modbus/TCP interface TNC-A1354 Technical data Description TNC-A1354 Supply voltage Current consumption Power consumption 24 V DC < 400 mA < 10 VA RS232C: RJ11; 9600 – 115200 Bd, galvanically isolated Ethernet CAA, RJ45; 10/100 MBd Modbus/TCP Yes 128 Kwords Graphic LC display 128 × 64 pixels, 43 × 28 mm < 95 % 2 × red; 3 x green; 4 × yellow 0 – 60 °C –20 to 70 °C IP 20 5 years M3 In preparation Aluminium, galvanised sheet steel 124 × 97 × 86 mm On DIN mounting rail Programming interface Data interface Diagnosis via PROFIBUS DP PLC memory for user program Display Max. acceptable rel. humidity Status LED Ambient temperature Storage temperature IP protection level MTTF AS-i profile AS-i certificate Casing materials Casing dimensions Fixing Wiring Connecting cable core identification TNC-A1354 AS-i 2+ AS-i ʹ̋ AS-i 1+ AS-i ʸ̋ 6 FE +24V 0V TNC-A1354 06/2015 – DE/en K4 – 6.2 – 9 TROXNETCOM AS-i Special information – TNC-A1354 62 86 Specification text 6 K4 – 6.2 – 10 4 131 AS-i controller TNC-A1354 124 Dimensions Controllers and repeaters 97 107 Standard description (characteristics) AS-i controller TNC-A1354 (2 master) is a compact AS-i master system with integral text/graphic display and Ethernet interface. (Modbus TCP) – Control of components as part of fire damper control Integral TNC Basic User Software with the following functions: – Automatic recognition of TROX modules and their functions – Automatic grouping – Network control – Automatic function test – Manual control of dampers – Integral display, also for operation – Simple, menu-driven configuration and adjustment – Supply voltage: 24 V DC – Total current consumption from AS-i: < 10 mA – Casing materials: Aluminium, galvanised sheet steel – Ambient temperature: 0 – 60 C° – IP protection level: IP 20 – Status display: LEDs, 2 x red, 3 x green, 4 x yellow – Make: TROX GmbH or equivalent – Type: TNC-A1354 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-A1375 Description Controllers and repeaters Application – AS-i gateway TNC-A1375 with 1 master for 31 AS-i slaves – Recognition of all slaves on a bus – Error diagnosis and signalling – LC display, 43 × 28 mm, also for operation – PROFIBUS DP interface TNC-A1375 Technical data Description Supply voltage Current consumption Power consumption Data interface Diagnosis via PROFIBUS DP Display Max. acceptable rel. humidity Status LED Ambient temperature Storage temperature IP protection level MTTF AS-i profile AS-i certificate Casing materials Casing dimensions Fixing Wiring TNC-A1375 26.5 – 31.6 V DC < 200 mA < 4 VA PROFIBUS-DP; max. 12 MBd; EN 50170 Yes Graphic LC display 128 × 64 pixels, 43 × 28 mm < 95 % 2 × red; 1 x green; 1 × yellow 0 – 60 °C –20 – 70 °C IP 20 5 years M4 In preparation Aluminium, galvanised sheet steel 124 × 97 × 86 mm On DIN mounting rail Connecting cable core identification TNC-A1375 6 AS-i 1+ AS-i ʸ̋ n.c. FE TNC-A1375 06/2015 – DE/en K4 – 6.2 – 11 TROXNETCOM AS-i Special information – TNC-A1375 62 85 Specification text 4 124 AS-i gateway TNC-A1375 138 Dimensions Controllers and repeaters 57 68 Standard description (characteristics) AS-i gateway TNC-A1375 is a compact gateway with PROFIBUS DP interface and without data processing. – Supply voltage: 26.5 – 31.6 V DC (AS-i) – Electrical design: SmartLink DP with 1 AS-i master – Total current consumption from AS-i: < 200 mA – Casing materials: Aluminium, galvanised sheet steel – Ambient temperature: 0 – 60 C° – IP protection level: IP 20 – Status display: LEDs, 2 x red, 1 x green, 1 x yellow – Make: TROX GmbH or equivalent – Type: TNC-A1375 6 K4 – 6.2 – 12 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-A2225 Description Controllers and repeaters Application – AS-i repeater TNC-A2225 allows for cable extension by 100 m – Modules are installed before and after the repeater – Galvanic isolation of two AS-i branches TNC-A2225 Technical data Description TNC-A2225 Supply voltage 26.5 – 31.6 V DC Current consumption 60 mA per AS-i segment AS-i interfaces 2 No. of additionally required AS-i power supply units 1 No. of repeaters/controllers/parallel operation Any number if according to AS-i specification No. of repeaters/controllers/series operation up to 2 Galvanically isolated Yes Power LED 2 x green Error LED 2 x red Ambient temperature 0 – 55 °C IP protection level EN 50295 MTTF 180 years Casing materials Note Wiring IP 20 EMC PA 6.6 The AS-i repeater has no slave address; total no. of AS-i slaves per master segment (31 or 62) remains unchanged, no parameter setting required Connecting cable core identification Outgoing AS-i cable A–: A+: A–: A+: AS-i – line 2 AS-i + line 2 AS-i – line 2 AS-i + line 2 Incoming AS-i cable A+: A–: A+: A–: 06/2015 – DE/en AS-i + line 1 AS-i – line 1 AS-i + line 1 AS-i – line 1 K4 – 6.2 – 13 6 TROXNETCOM AS-i Special information – TNC-A2225 25 Specification text 35,5 AS-i repeater TNC-A2225 114 Dimensions Controllers and repeaters 105 Standard description (characteristics) AS-i repeater allows for a cable extension by 100 m. – Total current consumption from AS-i: 2 x 60 mA – Output/connection: Combicon connector – Casing materials: PA 6.6 – Ambient temperature: 0 – 55 C° – IP protection level: IP 20 – Operation: LED, 2 × green – Error: LED, 2 × red – Make: TROX GmbH or equivalent – Type: TNC-A2225 6 K4 – 6.2 – 14 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-A003S Description Controllers and repeaters Application – AS-i safety monitor TNC-A003S – Safety monitor for monitoring data transmission and the AS-i controller, for safety related applications up to SIL 3 to IEC/EN 61508, e.g. for the control of smoke control dampers TNC-A003S Technical data Description TNC-A003S Supply voltage Residual ripple Rated operating current Peak switch-on current ¹⁾ Response time (safety related) Power ON delay time AS-i profile AS-i voltage range AS-i current consumption Interface RS 232 Start input Contactor control input 24 V DC ± 15 % < 15 % 150 mA 600 mA < 40 ms < 10 s Monitor 7.F 18.5 – 31.6 V < 45 mA 9600 Bd, no parity, 1 start bit, 1 stop bit, 8 data bits Optocoupler input (high active), input current approx. 10 mA (24 V DC) Optocoupler input (high active), input current approx. 10 mA (24 V DC) PNP transistor output, 200 mA, Safety ON message output ²⁾ short circuit and reverse voltage protection Volt-free NO contacts, max. contact load: 1 A DC-13 at 24 V DC, Safety output 3 A AC-15 at 230 V AC Fuse Externally, with 4 A MT max. Overvoltage category 3, for rated operating voltage 300 V AC to VDE 0110 part 1 Operating temperature –20 to 60 °C Storage temperature –30 to 70 °C IP 20 (only for use in rooms where electric systems operate/switch IP protection level cabinet with minimum IP 54) MTTFd 57 years Distance between 2 AS-i safety monitors 10 mm Casing dimensions 45 × 105 × 120 mm Casing material Polyamide PA66, black Fixing On DIN mounting rail ¹⁾ When all relays are switched on simultaneously; current for message outputs not taken into consideration ²⁾ The Safety ON message output is not safety related 06/2015 – DE/en K4 – 6.2 – 15 6 TROXNETCOM AS-i Special information – TNC-A003S Wiring Terminal connections of the AS-i safety monitor of TNC-A003S Terminal Signal/description AS-i ± L+ M FE 1.Y1 1.Y2 1.13 1.14 1.23 1.24 1.32 2.Y1 2.Y2 Connection to the AS-i bus +24 V DC supply voltage GND reference earth Functional earth EDM 1/input feedback circuit, output circuit 1 Start 1/Start input, output circuit 1 Output switching element 1, output circuit 1 Output switching element 1, output circuit 1 Output switching element 2, output circuit 1 Output switching element 2, output circuit 1 Safety ON/message output 1, output circuit 1 EDM 2/input feedback circuit, output circuit 2 Start 2/Start input, output circuit 2 45 Specification text 6 K4 – 6.2 – 16 135,5 AS-i safety monitor TNC-A003S 104 Dimensions Controllers and repeaters 120 Standard description (characteristics) Safety monitor for monitoring data transmission and the AS-i controller, for safety related applications up to SIL 3 to IEC/EN 61508, e.g. for the control of up to 4 smoke control dampers – Supply voltage: 24 V DC ±15 % – AS-i voltage range: 18.5 – 31.6 V – AS-i current consumption: < 45 mA – Operating temperature: –20 to 60 C° – Protection level: IP 20 (only for use in rooms where electric systems operate/switch cabinet with minimum IP54) – Make: TROX GmbH or equivalent – Type: TNC-A003S 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-ZB0252 Description TNC-ZB0252 Technical data Application – AS-i gateway TNC-ZB0252/F-Link for monitoring the inputs of safety related binary AS-i slaves – Compact, safety related gateway between PROFIBUS (DP slave) and AS-Interface – Core component of 'integrated safety', meant 'to close the gap in bus-based safety technology' – Monitoring of the inputs of fail-safe binary AS-i slaves (ASIsafe slaves) and data transmission via PROFIsafe. No need for additional safety related components for AS-Interface (e.g. safety monitor) – AS-i master according to AS-Interface specification V3.0, master profile M4, to connect up to 31 AS-i slaves, with integrated analog value transmission – Direct integration with PROFIBUS networks. Optional integration with PROFINET networks via PROFINET/PROFIBUS gateway (IE/PB link) or SIMATIC S7-315 F PN/DP – Optimised TIA integration in STEP 7 via Object Manager, inclusion in engineering tools by third parties via PROFIBUS type file (GSD) – On-site diagnosis using LEDs and a display with button – Assembly change without PG since start-up data is transmitted by PROFIBUS DP master Description Supply voltage Separate voltage supply Current consumption Power loss Data interface Supported protocols No. of AS-i slaves Bus cycle time with 31 slaves Bus cycle time with 62 slaves Max. acceptable relative humidity Ambient temperature Storage temperature IP protection level MTTF AS-i profile AS-i specification Safety integrity level Casing dimensions (B × H × T) Fixing 06/2015 – DE/en Controllers and repeaters TNC-ZB0252 24 V DC Yes 100 mA 3W PROFIBUS DP; RS 485 ASIsafe (safety at work) protocol, PROFIsafe protocol, PROFIBUS protocol Up to 62 5 ms 10 ms 10 - 95 % 0 – 50 °C –40 to 85 °C IP 20 36 years M4 V 3.0 SIL3 to IEC 61508 45 × 111 × 124 mm On DIN mounting rail K4 – 6.2 – 17 6 TROXNETCOM AS-i Special information – TNC-ZB0252 111 106 AS-i gateway TNC-ZB0252 80 Dimensions Controllers and repeaters 45 5 115 124 Specification text Standard description (characteristics) AS-i safety gateway for monitoring the inputs of safety related binary AS-i slaves and for data transmission via PROFIsafe. Direct integration with PROFIBUS networks via PROFIBUS type file (GSD). Connection of up to 20 AS-i safety modules AS-EM/SIL2. – Supply voltage: 24 V DC – Current consumption: 100 mA – Operating temperature 0 to 50 °C – IP protection level: IP 20 – Make: TROX GmbH or equivalent – Type: TNC-ZB0252 6 K4 – 6.2 – 18 06/2015 – DE/en TROXNETCOM AS-i Special information – TNC-Z0119 Description TNC-Z0119 Controllers and repeaters Application – Passive bus termination – Cable extension up to 200 m without additional repeater – Improved signal quality – Supply voltage monitoring with 2 LEDs – Connection to AS-i cable with flat cable connector – Can only be used when actuators have a separate voltage supply Technical data Description TNC-Z0119 (TNC-A1147 + TNC-70096) Type Supply voltage Current consumption Galvanically isolated Status LED Ambient temperature IP protection level MTTF Connection Note Type Max. current load Ambient temperature IP protection level Casing material Note Wiring TNC-A1147 26.5 – 31.6 V DC < 10 mA Yes Yellow = AS-i voltage > 18.5 V; green = AS-i voltage > 26 V –25 to 70 °C IP 67 550 years Flat cable insulation displacement connector No addressing required TNC-70096 2A –25 to 75 °C IP 67 PA No addressing required Connecting cable core identification TNC-Z0119 ݢ ݣ ʸ ʻ ʸ 2 2 3 ʻ 3 6 ① TNC-A1147 ② TNC-70096 Yellow when connected to an AS-i flat cable: 1 AS-I + 3 AS-I − 06/2015 – DE/en K4 – 6.2 – 19 TROXNETCOM AS-i Special information – TNC-Z0119 Dimensions Controllers and repeaters AS-i passive bus termination TNC-Z0119 40 ݣ 25 9 ݢ ① TNC-70096 ② TNC-A1147 Specification text Standard description (characteristics) Passive bus termination (TNC-A1147) with flat cable connector (TNC-70096) to make a connection to the AS-i flat cable. Bus termination to improve the signal quality and to extend the AS-i cable network Cable extension up to 200 m. – Supply voltage: 26.5 – 31.6 V DC – Current consumption: < 10 mA – Max. current load: 2 A – Ambient temperature: –25 to 70 C° – IP protection level: IP 67 – Make: TROX GmbH or equivalent – Type: TNC-Z0019 6 K4 – 6.2 – 20 06/2015 – DE/en 6.4 – X X Basic information and nomenclaturetestregistrierung TROXNETCOM Basic information and nomenclature ■ Communication systems for fire protection systems ■ Colour codes according to IEC 60757 ■ AS-Interface ■ LON 6 06/2015 – DE/en K4 – 6.4 – 1 TROXNETCOM Basic information and nomenclature Description Information and communication are becoming more and more important in today's world. People not only want more information, they also want more detailed information. This development is also visible in building automation, and there is no end in sight. A building becomes 'transparent' through distributed intelligence and new decentralised communication systems. These new technologies allow us to develop bespoke system solutions for various building services and to integrate them with building management systems. In this way, the best solutions for the different building services can be combined to create the best possible overall solution. Decentralised communication systems offer you the most advanced technology for your application requirements. Communication systems for fire protection systems The functional safety of programmable electronic systems is becoming more and more important in fire protection and is implemented with regard to protection goals and risks. According to IEC 61508, the requirements for these systems are based on a risk analysis. Components are given an SIL rating (safety integrity level) and must meet the corresponding requirements to ensure safety even in case of a malfunction. General advantages of decentralised bus systems It is no longer necessary to wire every single actuator and every single controller. Modern bus systems only need one bus cable, and in some cases a supply cable, to connect all components. This saves not only installation time but also cables, connectors, terminal blocks, and control cabinet space. It also drastically reduces the fire load and the installation costs. All signals from all components on a bus can be retrieved and recorded by the central unit. Inspection is simplified, and measurement and control can be optimised. Communications system ݢ ݥ ݣ ݤ 6 ① Central BMS ② Base station Wiring Colour codes according to IEC 60757 Code BK BN RD OG YE GN BU K4 – 6.4 – 2 ③ Bus ④ Field bus Colour codes according to IEC 60757 Colour Code black brown red orange yellow green blue VT GY WH PK TQ GNYE Colour violet grey white pink turquoise green-yellow 06/2015 – DE/en TROXNETCOM Basic information and nomenclature Description The AS interface is a world-standard bus system according to EN 50295 and IEC 62026-2. It enables the integration of different components (modules) in a network regardless of the manufacturer and the design. The modules control actuators and/or receive signals from sensors. TROX provides a system for controlling fire dampers, smoke protection dampers and smoke control dampers based on the AS-i standard. TROX modules are characterised by a wide spectrum of functions yet simple cabling. The system Communications system Special characteristics – Data exchange and power supply with just one cable – Central control of actuators and monitoring of damper blade positions and duct smoke detectors – Simple commissioning using standardised software – Automatic function test including data logging ݤ ݢ ݣ 6 K4 – 6.4 – 3 ① Communication master ② Controller units (master) ③ Modules (slaves) The communication master is the central display and control panel for the entire system. – Connection of up to 28 controller and power units – Display of operating status – Operation of actuators – Menu-driven operation in case of errors or malfunctions – System configuration at the time of commissioning – Logging of function tests and error messages The controller and power unit combines the control functions, the power supply, and the data exchange for all components on the bus. – The controller and power unit is installed near the modules, e.g. as a floor distributor – With TNC Basic User Software for fire and smoke protection – Communication interface to higher level systems (BACnet/Modbus) – Display, also for operation – Units with: 1 master – for 31 modules, 2 masters – for 62 modules The modules establish the link between the measurement and control signals (sensors and actuators) and the network on the so-called field level. A module provides the supply voltage for the operation of actuators. – Modules can be part of a fire damper or used separately to connect one or more fire dampers – Integrated monitoring function, e.g. for running time – Connection to the bus cable is with a flat cable insulation displacement connector 06/2015 – DE/en TROXNETCOM Basic information and nomenclature Description LON indicates a standard local operating network system with manufacturer-independent communications. Data is transferred by a microprocessor supplied by Echelon Corporation using a unified protocol. LonMark defines standards to ensure product compatibility. TROX offers components that meet LON standards. TROX modules are characterised by a wide spectrum of functions yet simple cabling. Special characteristics – Data exchange and power supply can be achieved with just one cable – Decentralised structure with high operational reliability – Standardised data transfer – Manufacturer-independent compatibility The system Network topology Binding network variables ݤ ݢ ݥ ݣ Free topology Network The local operating level (subnet) consists of the modules (nodes) and free topology data cables. A subnet can consist of up to 64 nodes or, alternatively, can be extended to 128 nodes using a repeater or router. Physical data transfer is via systems with or without a transfer of supply voltage. All nodes of a subnet must comply with the system. In larger networks the routers link the subnets with each other. The routers communicate with each other via the backbone, on a separate network level. Central monitoring of a LON network is possible and is connected to the backbone or above it. ① Switch cabinet ② Duct smoke detector ③ Damper blade position ④ Alarm Data exchange Network variables are used for the communication between the nodes. These variables ensure unambiguous data exchange between the nodes. For commissioning, it is necessary to link the network variables between the nodes (binding). Project software is used to link the outputs of a node to the inputs of other nodes. Binding information is transferred to the subnet. Binding is carried out by a system integrator. 6 06/2015 – DE/en K4 – 6.4 – 4
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement