SMLP5-5 Single-mode / Multimode Test Kit with Wave ID

SMLP5-5 Single-mode / Multimode Test Kit with Wave ID
SMLP5-5 Single-mode / Multimode Test
Kit with Wave ID, Set Reference, and
Data Storage
Features
• Rugged, handheld, lightweight
• Designed for field use
• Certify multimode and single-mode links
per TIA/EIA standards
• Wave ID - automatic wavelength identification and switching
• Dual Wave ID, single Wave ID, CW, and
modulated Tone (on single-mode output)
• 270 Hz, 330 Hz, 1 kHz, and 2 kHz Tone
• Large LCD with Backlight
• Power measurements in dBm or µW;
insertion loss in dB
• Reference power level storage
• Up to 500 test records per wavelength
storage and download
• USB port for download of stored records
• AA alkaline, optional rechargeable NiMH
battery pack or AC adapter
• Low battery indicator
• Free Windows® compatible software to
view, print, and archive test records
• Free 50 µm and 62.5 µm mandrels
• Cost-effective, easy to use
• N.I.S.T traceable
The SMLP5-5 test kit combines the OPM5-2D optical power meter and OLS4 integrated
LED and LASER light source and is ideally suited for testing fiber optic networks with
hybrid (single-mode and multimode) cables.
The OLS4 features 850 nm and 1300 nm LED output from a multimode output port and
1310 nm and 1550 nm LASER output from a single-mode output port. The LED and
LASER outputs are stabilized to ensure accurate test results per current TIA/EIA requirements. This light source offers 4 modes of operation: Dual wavelengths sending ID, single
wavelength sending ID, CW, and modulated Tone. [Active Output], [Tone], [Battery], and
[External Power] indicators identify the currently enabled operating mode, battery charge
status, and external power presence. Both output ports are equipped with UCI based
removable adapters to allow the output connectors to be inspected and cleaned.
The OPM5-2D offers Wave ID, automatic wavelength identification and switching, when
used with the OLS4 light source. Multiple test Tone detection is provided for fiber identification. The OPM5-2D stores optical references for each calibrated wavelength. An easy to
read Dual Wavelength LCD display with Backlight shows measured power [dBm or µW] or
insertion loss [dB], calibrated wavelengths, tone signal [Hz], wavelength ID, and the battery
charge status. Up to 500 records per wavelength of power or insertion loss measurements
may be stored in internal non-volatile memory.
Using the supplied Windows® compatible software and USB connection, test records may
be transferred to a PC for storage, display, analysis, and printing.
In addition to being powered by two AA alkaline, the OPM5-2D or OLS4 can be powered by
optional AC adapter and/or rechargeable NiMH battery pack.
The OPM5-2D optical input port accepts Noyes thread-on style adapter caps. Adapter caps
are required for operation and must be ordered separately.
The OPM5-2D and OLS4 are fully N.I.S.T. traceable.
Ordering Information
Model
Includes
SMLP5-5
OLS4 optical light source, OPM5-2D optical power meter, AA batteries, protective rubber boots,
adapter cap, USB cable, Windows® compatible software and user's guide, 50 and 62.5 µm
mandrels, SMLP5-5 test kit user's guide, and carry case
Test jumpers and connector adapters are required for operation (purchased separately).
Test jumpers with a variety of connector styles and fiber types and adapter caps for most
common connectors may be purchased from AFL Telecommunications.
continued on the next page
Test & Inspection
© 2002, AFL Telecommunications, all rights reserved. SMLP-55-2001 Revision B, 9.19.06
Specifications are subject to change without notice.
1
SMLP5-5 Single-mode / Multimode Test Kit with Wave ID, Set
Reference, and Data Storage
OLS4 Light Source specifications
Optical
Wavelength
Emitter type
Output power
Spectral width (FWHM)
Optical connectors
Stability
MM Optical Port
SM Optical Port
850 ± 30 nm 1300 -10/+50 nm
1310 ± 20 nm
1550 ± 20 nm
LED,
Laser,
Class 1 (IEC 60825 - 1)
Class 1 (FDA 21 CFR 1040.10 and 1040.11, and
IEC 60825-1)
0 dBm, 9 µm Single-mode
> - 20 dBm, 62.5 µm Multimode*
40 nm (typ)
120 nm (typ)
5 nm (max)
5 nm (max)
SC (FC, ST, or LC available)
SC (FC, ST, or LC available)
± 0.1 dB over 8 hours
± 0.05 dB over 1 hour (after 15 min. warm-up)
(after 5 min. warm-up)
± 0.1 dB over 8 hours (after 15 min. warm-up)
General
Power
Battery life (2 x AA)
Operating temperature
Storage temperature
Size (H x W x D)
Weight
2 x AA batteries, optional NiMH or AC adapter
Typical 30 hours, Minimum 20 hours
Typical 120 hours, Minimum 75 hours
-10 to 50°C, 90% RH (non-condensing)
-30 to 60°C, 90% RH (non-condensing)
5.5 x 3.2 x 1.5 in (14.0 x 8.1 x 3.8 cm)
0.65 lb (.29 kg)
* Output power will be approximately 3 dB less if a 50 µm mandrel-wrapped jumper is used instead of
a 62.5 µm mandrel-wrapped jumper.
All specifications at 25°C.
OPM5-2D Power Meter specifications
Optical
OPM5-2D
Calibrated wavelengths
850, 1300, 1310,1550nm
Detector type
Germanium (Ge)
Measurement range (dBm)
+6 to -60
Tone detect range (dBm)
+6 to -50
+6 to -45 for 850nm
Wavelength ID range (dBm)
+6 to -50
+6 to -45 for 850nm
Accuracy (dB)*
± 0.25
Resolution (dB)
0.01
Measurement units
General
dB, dBm, µW
Power
2 x AA batteries, optional NiMH or AC adapter
Battery life (2 x AA)
300 hours with backlight [Off]
20 hours with backlight [On]
Operating temperature
-10 to 50°C, 90% RH (non-condensing)
Storage temperature
-30 to 60°C, 90% RH (non-condensing)
Size (H x W x D)
5.5 x 3.2 x 1.5 in (14.0 x 8.1 x 3.8 cm)
Weight
0.58 lb (0.26 kg)
* Accuracy measured at 25ºC and -10 dBm per N.I.S.T. standards.
All specifications at 25°C
Test & Inspection
© 2002, AFL Telecommunications, all rights reserved. SMLP-55-2001 Revision B, 9.19.06
Specifications are subject to change without notice.
2
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement