Amplifier
Amplifier
Page 43 – Page60
Overview
Technical data
CATV amplifiers
- House connection amplifiers eco-power
- House connection amplifiers midi-power
- House connection amplifier high-power
- Line-/distribution amplifier
- Accessories
Super wideband amplifiers
- Amplifiers for terrestrial and SAT signal
Multi-band amplifier
Terrestrial multi-purpose amplifiers
Amplifier
43
Amplifier
Overview - CATV amplifiers
Apartment amplifier
| House connection amplifiers
eco-power + eco-power
Product family
eco-power +
gital
or di
able f
Suit
Use
Flats, detached and Smaller building distribution systems
Semi-detached homes
With multimedia capability (return channel)
•
•
•
•
Types
GHV
GHV GHV
GHV
GHV
GHV
GHV
Mains supply 230V
24 E
20 M 20 E
820 A
820 C
30 E
833
Remote feeding
HF - connections
F
F F
F
F
F
F
Level attenuator • Pot.
• Pot. • Pot.
• Pot.
• JME
• Pot.
• Pot.
Line equaliser • Pot.
• JME
•
• Pot.
Interstage preemphasis
Return path options
ROB1)
VHFI/RP switch over
Return path modules
5 - 30 MHz
5 -65 MHz
-
-
-
-
-
-
p
-
-
-
-
•
-
-
-
-
-
-
p, a
•
-
-
-
•
p, a
•
•
-
-
•
-
-
-
-
-
-
p
-
-
-
•
-
Output level (forward)
IMA3 > 60 dB (EN 50083-5) dBµV
CSO > 60 dB (CENELEC 42Ch) dBµV
CTB > 60 dB (CENELEC 42Ch) dBµV
Basic gain
dB
103
91
91
103
87
90
113
97
100
113
97 100 113
99 101 115
101
101
115
103 103
17/18
10/12
21
21
21
29
29
1)
ROB: Return channel on board with VHF switchover
Can be switched from 862 MHz to 606 MHz
Interstage Slope 7 dB
4) Regulated output level range
5) 5/8" connection on request
2)
3) Output level dBµV
(CTB 60 dB)
CENELEC 42 CH
GPV / GLV
high-power
110
GPV
high-power
GHV
midi-power
105
100
95
+
GHV
eco-power+
GHV
eco-power+
GHV
eco-power
90
85
4
44
8
16
24
32
Number of
connections*
•
•
Line / distribution / control amplifiers
high-power midi-power
Medium-sized
building
|
Large house
installations
•
GHV
GHV
GHV
GPV
830 A
830 C
834 C
845 E
F
F
F
F
• Pot.
JME
JME
• Pot.
• Pot.
JME
JME
• Pot.
•
•
•
high-power +
CATV distribution
distribution
Line amplifier
installations
•
•
•
•
GPV
845 C
845 CF
F 5/8" 5)
jme
jme
•
GPV
851 I
851 F
F
• Pot.
• Pot. 2)
•
GPV 865
865 F
PG11
• Pot.
• Pot. 2)
•
GLV …
865 AGC
865 F AGC
PG11
• Pot.
• Pot. 2)
p, a
•
-
-
-
•
p, a
•
•
-
-
•
p, a
•
•
-
-
•
-
-
-
-
-
-
p, a
•
•
•
•
•
p, a
m
•
•
•
•
p, a
m
•
•
•
•
p, a
m
•
•
•
•
115
101 101
115
103 102 118
106 3)
105 3)
123
111 3)
110 3)
123
111 3)
110 3)
124
114 3)
114 3)
124
114 3)
114 3)
(124)
(95 - 105)
30
30
34
36/30
36/30
36/29
36/29
28
Pot.
JME
p
a
m
4)
=potentiometer
=Jumper Matrix Elemente
=passive return channel
=active return channel
=return path via plug-in modules
Application example
A : Home connection point
B : House connection amplifiers
GHV… / GPV…
C : Tap-off AFC 1861
D
D : Antenna outlet socket EDU 04 F
E : Line amplifier GLV 865 F
F : Tap-off
C
A
E
F
B
45
Amplifier
House connection amplifiereco-power
Type
Small but powerful
The house connection amplifiers are
optimal CATV amplifiers for smaller
building units without return channel
utilisation.
GHV 20 E and GHV 30 E.
These inexpensive amplifiers are
suitable for digital TV and ideal for use
in (MATV and SMATV) systems.
• Very efficient with extremely low
power consumption
• Compact integrated transformer
power supply unit with permanent
screw-on housing
– Shock protection even when
the amplifier is opened
• Control elements:
– Removable cover main screw
allows easy configuration
– Not accessible when closed thus protected from tampering
• The die-cast basic housing reduces
component temperature to increase
service life and reliability.
• Satisfies the standards
EN 60065
EN 50083-1
EN 50083-2, Class A
EN 50083-3, quality class 2
•
GHV 24 E
CATV indoor distribution amplifier
with integrated 4-way tap-off
The GHV 24 E apartment amplifier has
4 outputs for direct, point-to-point
distribution of analog and digital signals.
The ideal distributor amplifier without
return channel utilisation for
• Apartments
• Family homes and semi-detached
homes
• Small apartment blocks
• Single floors in large apartment
blocks
Special features:
• Amplification adjustable from
0 to 18 dB
• Outputs decouples using directional
coupler
• TV band I compatible
• 1 GHz amplifier technology
• High level output at low power
consumption
• High-quality die-cast housing with
integrated power supply unit
• Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2,
•
Advantages offered by the compact
solution:
No external tap-offs, or distributors,
therefore:
• Easier and visually appealing
installation in residential buildings
• Increased reliability
• Cost advantages
46
GHV 20 E
GHV 30 E
GHV 24 E
940 023-001 940 024-001
941 081-001
Return/forward MHz-- / 40...862
-- /40...862
-- / 40....862
(1000 )
( 1000) (1000)
21
29
Order number
Frequency range
Gain @ 862 MHz
dB @ 862 MHz output 1
dB
16
@ 862 MHz output 2, 3, 4
dB
17
Level attenuator
dB 0...20
0...20 0...20
Linearity amplitude frequency response
40...862 (1000) Mhz
dB
1.5 (3) 1.5 (3)
1.5
Fixed slope
dB
+1
+1
+1
Noise factor dB 4.5 4.5
4.5
dB >14
>14
>14
IMA 2 in acc. with EN 50083-3 dBµV 100 105
92
IMA 3 in acc. with EN 50083-5 dBµV 113 115
103
CSO Cenelec 42 chan. 862 MHz dBµV 97 101
91
CTB Cenelec 42 chan. 862 MHz dBµV 100 101
91
Return loss
40 MHz, -1.5 dB/octave
Output level, IMA = 60 dB
HF connectors (75 W )
Input
F-socket
F-socket
F-socket
Output
F-socket
F-socket
F-socket
Decoupling of outputs
Operating conditions
Maximum output level (EMC)
Dimensions W x H x D
Operating voltage
Power consumption
dB
30
dBµV
mm
V
W
105
150 x 80 x 50
230 10% 5
105
150 x 80 x 50
230 10% Power
5
-25 ... +55
II
IP 20
0.64 yes
-25 ... +55
II
IP 20
0.64
yes
105
150 x 80 x 50
230 10%
3
Operating temperature range
°C
-25 ... +55
Protection class II
Protection class (IP)
IP 20
Weight
kg
0.64
RoHS 2002/95/EC conformant
yes
House connection amplifiereco-power
Type
GHV 20 M
Order number
940 030-061
d
ouple
c
e
d
Four tputs
Ou
Forward
reverse
Frequency range MHz 85...862
5...65
@ 862 (65) MHz output 1 (data)
dB
12
@ 862 MHz output 2, 3, 4
dB
10,5
dB 0...20 GHV 20 M
IMA 2 in acc. with EN 50083-3 dBµV 90
IMA 3 in acc. with EN 50083-5 dBµV 103 dBµV
87 CATV in-premises amplifier with integrated 4-way tap-off
The GHV 24 E apartment amplifier has 4
outputs for direct, point-to-point distribution of analog and digital signals.
The ideal distribution amplifier with
return channel applications
• Apartments
• Family homes
Special features:
• Return channel capable data output 1
5...65 MHz
• Outputs decoupled via directional
couplers
• High-quality die-cast housing with
integrated power supply unit
• Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2,
dBµV 90 •
Input
F-socket
Output
F-socket
Advantages offered by the compact
solution:
No external tap-offs, or splitters,
therefore:
• Easier and visually appealing
installation in residential buildings
• High decoupling between data
return channel and other
connections suppresses
interference
• Increased reliability
• Cost advantages
Gain Level attenuator
Linearity amplitude frequency response
Noise factor -1.0
dB
1.5
dB 4.5 dB >14
Return loss
@ 40 Mhz, -1.5 dB/octave
Output level, IMA = 60 dB
CSO Cenelec 42 chan. 862 MHz
CTB Cenelec 42 chan. 862 MHz HF connectors (75 W )
Operating conditions
Maximum output level (EMC)
Dimensions W x H x D
dBµV
mm
105
150 x 80 x 50
Operating voltage
V
230 Power consumption
W
3
Operating temperature range
°C
-25 ... +55
Protection class
II
Protection class (IP)
IP 20
Weight
0.65
kg
RoHS 2002/95/EC conformant
yes
47
Amplifier
House connection amplifiereco-power with return channel (pas-
GHV 820 A/GHV 830A
The optimal solution for preparing
house distribution networks for expansion. The multimedia enabled amplifiers
are suitable for digital TV and interactive
services, and ideal for implementation in
smaller building units and CATV domestic networks.
"All on board".
iForward channel for TV band 1 or
return channel are alternatively available through configuration of the
diplex filters
iIntegrated return channel amplifier
can be connected via jumper
iReturn channel optionally active/
passive/blocked.
• Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2
•
Type
GHV 820 A
GHV 830 A
Order number
940 020-065 940 022-065
Frequency range MHz Setting: VHF I "on", RC "off"
-/40...862 Setting: VHF I "off", RC "on"
5...65 /85...862
-/40...862 5...65 /85...862
Gain forward
@ 862 Mhz
dB 21
30
Level attenuator dB 0...20
0...20
dB
0..18 0...18
Line equaliser
Amplification backward
@ 60 MHz via output 1
Level attenuator (input RC)
Attenuation Jumper (output RC) dB -1,5/20
-1,5/24
dB
0...20
0...20
dB
0/10
0/10
dB
1.5
1.5
dB 5.5 5.5
dB >14
>14
Linearity amplitude frequency response
40...862 (1000) MHz
Noise factor
forward (VHF I "on")
Return loss
@ 40 Mhz, -1.5 dB/octave
Output level forward IMA/IMA >60 dB dBµV 100/113 105/115
CSO/CTB >60 dB, 42 ch,
dBµV 97/100
101/101
Input
F-socket
F-socket
Output
F-socket
F-socket
HF connectors (75 W )
Operating conditions
Maximum output level (EMC) dBµV
105
105
Dimensions W x H x D
mm
150 x 80 x 50
150 x 80 x 50
Operating voltage
V
230 10%
230 10% Power consumption
W
4.5
6
Operating temperature range
°C
-25 ... +55
-25 ... +55
Protection class
II
II
Protection class (IP)
IP 20
IP 20
Weight
0.64
0.64 yes
yes
kg
RoHS 2002/95/EC conformant
48
House connection amplifiereco-power with return channel (pasType
GHV 820 C
GHV 830 C
Order number
940 020-062 940 022-062
Frequency range GHV 820 C/GHV 830 C
Setting: VHF I "on", RC "off"
MHz
-/40...862
Setting: VHF I "off", RC "on"
MHz
5...65 /85...862
-/40...862 5...65 /85...862
Gain forward @ 862 MHz
dB
21
30
Attenuator (2 dB increments) input dB 0...16
0...16
0...16
0...16
-1.5/25
Line equalisation (2.5 dB increments)
dB
Gain return path
@ 60 MHz on output 1 dB
-1.5/20
Attenuator increments input dB
0/3/6/9/50
0/3/6/9/50
Attenuator increments output dB
0/10
0/10
Linearity amplitude frequency response
40...862 (1000) MHz
dB
1.5
1.5
Fix slope
dB
+1
+1
dB
1.5
1.5
forward (VHF I "on")
dB 5
5
return path (VHF I "off")
dB
6
6
dB >14
>14
IMA2 >60 dB dBµV 100
105
IMA3 >60dB dBµV
113
115
CSO >60 dB, 42 ch, Slope 0/7
dBµV
97/99
101/103
CTB >60 dB, 42 ch, Slope 0/7
dBµV 100/101
100/102
Input
F-socket
F-socket
Output
F-socket
F-socket
Linearity amplitude frequency response
5...60 MHz
Noise factor
Return loss
@ 40 Mhz, -1.5 dB/octave
Output level forward GHV 820 C and GHV 830 C are multimedia-enabled house connection
amplifiers
for smaller to medium-sized building
units. All important function units such
as
forward amplifier, diplex filters, return
channel amplifier and the
associated actuators are
completely implemented on the
PCB. Easy migration
of the return channel "TV band I"
or "return channel 65 MHz"
can be selected, return channel
switchable: "active or "passive". adjustment of the return channel amplification
by means of adjustable attenuators
on the input and output
Structure
• Increased long-term stability
thanks to discrete, switchable
attenuators and equalisers
(i.e. potentiometers are not used)
• Compact integrated transformer
power supply with permanent
screw-on plastic hood as shock
protection
• Maximum output level 110 dBμV
• Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2,
•
HF connectors (75 W )
Operating conditions
Maximum output level (EMC) dBµV
110
110
Dimensions W x H x D
mm
150 x 80 x 50
150 x 80 x 50
Operating voltage
V
230 10%
230 10% Power consumption
W
5
6
Operating temperature range
°C
-25 ... +55
-25 ... +55
Protection class
II
II
Protection class (IP)
IP 20
IP 20
Weight
0.64
0.64 yes
yes
kg
RoHS 2002/95/EC conformant
49
Amplifier
House connection amplifier midi-power with return channel (pasType
GHV 834 C
Order number
940 030-062
Frequency range GHV 834 C
GHV 834 C is a multimedia-enabled
house distribution amplifier
for medium-sized building units.
All important function units such as
forward amplifier, diplex filters, return
channel amplifier and the
associated actuators are
completely implemented on the
PCB. Easy migration
of the return channel "TV band I"
or "return channel 65 MHz"
can be selected, return channel
switchable: "active or "passive"
adjustment of the return channel
amplification by means of adjustable
attenuators on the input and output
Structure
• Increased long-term stability
thanks to discrete, switchable
attenuators and equalisers
(i.e. potentiometers are not used)
• Compact integrated transformer
power supply with permanent
screw-on plastic hood as shock
protection
• Maximum output level 110 dBμV
• Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2,
•
Setting: VHF I "on", RC "off"
MHz
Setting: VHF I "off", RC "on"
MHz
-/40...862
5...65 / 87...862
Gain forward
@ 862 MHz
dB 34 Attenuator input (2 dB increments) dB 0...16 Line equaliser (2.5 dB increments)
dB
0...16
Interstage pre-equalisation dB
0/7
Gain return path
@ 60 MHz on output 1
dB
Attenuator increments input
dB
-1.5/26
0/3/6/9/50
Attenuator increments output
dB
0/10
Linearity amplitude frequency response
47...862 MHz
dB
1.5 Fix slope
dB
+2
Noise factor dB 6
Return loss
@ 40 MHz, -1.5 dB/octave
dB
>14
Output level, IMA = 60 dB
IMA 2 in acc. with EN 50083-3 dBµV 112
IMA 3 in acc. with EN 50083-5 dBµV 118 CSO (42 chan. 862 MHz) Slope 0/7 dBµV 104 /106
CTB (42 chan. 862 MHz) Slope 0/7 dBµV 103 / 105 HF connectors (75 W )
Input
F-socket
Output
F-socket
Operating conditions
Maximum output level (EMC)
Dimensions W x H x D
dBµV
mm
Operating voltage
V
230 +6 / -10%
Power consumption
W
7.5
Operating temperature range
°C
-25 ... +55
Protection class
II
Protection class (IP)
IP 20
Weight
0.68
kg
RoHS 2002/95/EC conformant
50
110
150 x 80 x 50
yes
Line / distribution amplifiers high-power
Type
GPV 845 C
GPV 845 CF
Order number
940 153-061 940 154-061
GPV 845 C / CF
Frequency range MHz Setting: VHF I "on", RC "off"
-/40...862 -/40...862 Setting: VHF I "off", RC "on"
5...65 /85...862
5...65 /85...862
Gain forward
@ 862 Mhz
dB 36
36
Attenuator (2 dB increments) input dB 0...16 0...16
Equaliser (2 dB increments) input dB
0...16
0...16Interstage / attenuation
(jumper)
dB
0/6
0/6
dB
0/7
0/7
Interstage / equalisation (jumper)
Gain return path @ 60 MHz dB
-1.5/26
-1.5/26
Attenuation on the input dB
0/2/4/6/50
0/2/4/6/50
Attenuation on the output dB
0/3/6/9
0/3/6/9
Linearity amplitude frequency response
40...862 (1000) Mhz
dB
1.5
1.5
Fix slope
dB
+1
+1
dB
1.5
1.5
forward (VHF I "on")
dB 5.5
5.5
Return channel (VHF I "off"
dB
6
6
dB >14
>14
Linearity amplitude frequency response
5...60 MHz
Noise factor
Return loss
@ 40 Mhz, -1.5 dB/octave
Output level forward IMA2 >60 dB dBµV
114
114
IMA3 >60 dB
dBµV
123
123
CSO >60 dB, 42 ch, Slope 0/7
dBµV
109/111
109/111
CTB >60 dB, 42 ch, Slope 0/7
dBµV
108/110
108/110
Input
F sockets
F sockets
Output
F sockets
F sockets
HF connectors (75 W )
Operating conditions
Maximum output level (EMC)
Dimensions WxHxD
dBµV
113
113
mm
150x80x50
150x80x50
Operating voltage
V
180...253
25...65 Power consumption
W
9
9
-25 ... +55
-25 ... +55
Protection class
Operating temperature range
°C
II
II
Protection class (IP)
IP 65
IP 65
Weight
2
0.64 yes
yes
kg
RoHS 2002/95/EC conformant
GPV 845 C (CF) is a multimedia-enabled
house connection amplifier for mediumsized to larger building units. It is used
to compensate the cable and distribution attenuation in the CATV domestic
network. "All on board" - all important
functional units such as forward
amplifier, diplex filters, return channel
amplifier and the associated actuators
are completely implemented on the
PCB. The amplifier is configured for the
specific case via jumpers in the device
and settings can be made during
installation as well as operation.
migration of the return channel
• Easy
without additional modules. Either
"TV band I" or "Return channel 65
MHz" 1) can be selected. Adjustable
return channel: "active / "passive" /
"off". Optimal adjustment of the return
channel amplification (C/N) by means
of adjustable at the input and output.
long-term stability due to
• Increased
discrete, switchable attenuators and
equalisers, i.e. neither potentiometers
nor a large number of plug-in pads
are necessary
•
High output level with extremely low power consumption thanks to MMIC GaAs push/pull output stage
and switched-mode, high-efficiency
power supply
service life through low
• Long
temperature development (low power
consumption and diecast housing
with cooling fins and extensive
protection against ESD and surge
voltage
•
Power supply GPV 845 C Local supply from 230 V
- domestic network
GPV 845 CF remote feeding via
coaxial HF input
•
•
Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2,
51
Amplifier
Line / distribution amplifiers high-power
Type
GPV 845 E
Order number
940 153-001 GHV 845 E
Frequency range MHz
GPV 845 E is a variant of the highpower GPV 845 house connection
amplifier family, especially equipped for
MATV installations with local SMATV
headends that do not provide any interactive services via this network.
Features:
• Only the forward path - including
VHF band I is implemented
• Level adjuster and line equaliser
with potentiometers.
• High output level at extremely
low power consumption through
MMIC GaAs push/pull output stage
and switched-mode,
high-efficiency
Power supply:
• Local supply from 230 V domestic
network
• Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2,
•
Gain forward
40...862 @ 862 Mhz
dB 36
Attenuator / input dB 0...20
Line equaliser / input
dB
Interstage attenuation
Interstage pre-equalisation
0...17 dB
0/6
dB
0/7
Linearity amplitude frequency response
40...862 (1000) Mhz
dB
1.5
Fix slope
dB
+1
Noise factor
dB
5
Return loss
@ 40 Mhz, -1.5 dB/octave
dB >14
Output level, IMA = 60 dB
IMA 2 in acc. with EN 50083-3
dBµV IMA 3 in acc. with EN 50083-5
dBµV
114
123
CSO (42 chan. 862 MHz) Slope 0/7 dBµV 109 / 111
CTB (42 chan. 862 MHz)Slope 0/7 dBµV 108 / 110
HF connectors (75 W )
Input
F-socket
Output
F-socket
Test point output (bi-directional)
F-socket, -20 dB
Operating conditions
Maximum output level (EMC)
Dimensions W x H x D
Operating voltage
dBµV
105
mm
150 x 80 x 50
V
180...253
Power consumption
W
6.4
Operating temperature range
°C
-25 ... +55
Protection class
II
Protection class (IP)
IP 65
Weight
kg
RoHS 2002/95/EC conformant
52
2.0
yes
House connection amplifierhigh-power
Order number
Frequency range +
GPV 851 I
GPV 851 F
944 770-013
944 777-001
GPV 851 I / GPV 851 F
MHz
Device without return channel modules
47 ... 862
47 ... 862
36
0 ... 20
0/7
36
0 ... 20
0/7
Gain @ 862 Mhz
Level attenuator Interstage slope
dB
dB
dB
Linearity amplitude frequency response 47...862 Lineequaliser
Equalisation / switchable
Interstage / pre-equalisation
dB
MHz
dB
Noise factor
Noise factor
1.5
0 ... 18
0 ... 18
862 / 606
862 / 606
0/7
0/7
7
7
>14
>14
dB
Output level forward IMR2/IMR3 >60 dB 1.5
dB
Return loss
@ 40 Mhz, -1.5 dB/octave
MHz
dBµV
CSO/CTB >60 dB, 42 ch,
dBµV
117 / 124 dBµV
117 / 124 dBµV
Pre-equalisation 7 dB
HF connectors (75 W )
Input
Output
Test point input: bi-directional
Test point output: bi-directional
dBµV
113 / 112 dBµV
114 / 114 dBµV
113 / 112 dBµV
114 / 114 dBµV
F-socket
F-socket
F-socket
-30 dB
-30 dB
F-socket
-30 dB
-30 dB
113 dBµV
113 dBµV
dB
dB
Operating conditions
Maximum output level (EMC)
dBµV
Dimensions W x H x D
mm
Operating voltage
V
190 x 110 x 85
190 x 110 x 85
Power consumption
W
195 ... 244 V
32 ... 65 V
Operating temperature range
°C
13
-40°... +55°C
14
-40°... +55°C
Protection class (IP)
II
II
Weight
kg
65
2.0
65
2.0
Product standard
EN 50083-3, Class 2
EN 50083-3, Class 2
Safety standards
EN 50083-1; EN 60065
EN 50083-1; EN 60065
EMC
EN 50083-2
EN 50083-2
RoHS 2002/95/EC conformant
yes
yes
Protection class
Standards
• Implementation in local CATV distribution networks to 862 MHz
• Power doubler output stage
• HF connectors with F sockets (female)
• Die-cast housing, protection class
IP 54 (when using the appropriate
F connectors), for installation inside
and outside of buildings
• Local supply or remote feed
• Two basicamplifications selected
using internal jumpers (Interstage)
• Equalisation with internal jumpers
can be switched from 606 MHz or
862 MHz
• Level adjuster on the input
• Equalisation frequency-dependent line attenuator on the input
• Return channel
(in conjunction with plug-in modules)
– passive with diplex module
– active with return channel module
• With diplex modules individual
configurable return channel and Forward channel 5-30 MHz
47-862 MHz, 5-65 MHz, 85-862 MHz
• Return channel modules, with
adjusters for level and
frequency-dependent line attenuation
• Screw clamp for equipotential
bonding outside on the housing
• Satisfies EN 50083-1, 2 return loss in accordance with
EN 50083-3 quality class 2
•
Note
• Diplex and return channel modules
are listed after the line/ distribution amplifiers
Remote feed version GPV 851 F
• Selectable remote feed route:
– via input
– via output
– feed through
53
Amplifier
Line/distribution amplifier
GLV 865/865 F
• Implementation in CATV distribution
networks to 862 MHz
• Power doubler output stage
• HF connectors for PG 11 Screw-fastening
• Diecast housing, protection class
IP 65 for installation inside and
outside of buildings
• Cascading up to 5 devices
• Local supply or remote feed
• Two basic amplifications selectable with internal jumpers (Interstage)
• Equalisation with internal jumpers
can be switched from 606 MHz or
862 MHz
• Return channel (in conjunction with plug-in modules)
– passive with diplex module
– active with return channel module
• With diplex modules individual
configurable return channel and Forward channel 5-30 MHz 47-862 MHz
5-65 MHz 85-862 MHz
• Return channel modules, with
adjusters for level and frequency dependent line attenuation
• GLV…F: remote feed via input, output or loop-through of the remove
feed voltage can be selected by
plugging fuses into different sockets
• Additional internal terminals for direct
feed voltage connection
• Internal F test sockets on input and
output for forward channel and return
channel measurements
• Input and output are surge protected
• Screw clamp for equipotential bonding on the exterior of the housing
• Satisfies EN 50083-1, -2, 50083-3
Class 2
•
Note
• Diplex and return channel modules
are listed after the line/distribution
amplifiers • Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2,
54
Type
GLV 865
GLV 865 F
Order number
944 409-002
944 410-002
47 ... 862
47 ... 862
dB
36
36
Level attenuator dB
0 ... 20
0 ... 20
Interstage attenuation
dB
0/7
0/7
Linearity amplitude frequency response
47...862 MHz
1.5
1.5
Line equaliser 0 ... 18
0 ... 18
Freuency range
MHz
Basic device without return channel modules
Gain @ 862 Mhz
Equalisation / switchable
Interstage / pre-equalisation
dB
862 / 606
862 / 606
dB
0/7
0/7
dB
7
7
dB
>14
>14
MHz
Noise factor
Noise factor
Return loss
@ 40 Mhz, -1.5 dB/octave
Output level forward IMR2/IMR3 >60 dB dBµV
117 / 124
117 / 124
CSO/CTB >60 dB, 42 ch,
dBµV
113 / 112
113 / 112
Pre-equalisation 7 dB
dBµV
114 / 114
114 / 114
PG 11
PG 11
PG 11
- 20 dB
- 20 dB
PG 11
- 20 dB
- 20 dB
113
190 x 110 x 85
195 ... 244
13
-40°... +55°C
II
65
2.0
EN 50083-3, Class 2
EN 50083-1; EN 60065
EN 50083-2
113
190 x 110 x 85
32 ... 65
14
-40°... +55°C
II
65
2.0
EN 50083-3, Class 2
EN 50083-1; EN 60065
EN 50083-2
yes
yes
HF connectors (75 W )
Input
Output
Test point input: bi-directional
Test point output: bi-directional
Operating conditions
Maximum output level (EMC)
dBµV
Dimensions W x H x D
mm
Operating voltage
V
Power consumption
W
Operating temperature range
°C
Protection class
Protection class (IP)
Weight
kg
Standards
Product standard
Safety standards
EMC
RoHS 2002/95/EC conformant
Line / distribution amplifiers with automatic level control
Type
GLV 865 AGC GLV 865 F AGC
Order number
944 786-002
944 799-002
Frequency range 1) MHz 47 ... 862
47 ... 862
Description
Basic gain dB 28
28
Noise factor dB 7
7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Output level in accordance with DIN EN 50083
at 60 dB IMA second order dBµV 117
117
at 60 dB IMA third order dBµV 124 124
Cenelec CSO at 100 dBµV dB 69
69
dB 78
78
Total level analysis
MHz 47 ... 320
47 ... 320
Setting range dBµV 95 - 105
95 - 105
Delivery condition dBµV 100
100
Control stroke dB ±5
dB 18
18
2)
CTB at 100 dBµV Return loss on
input and output Impedance W
75
75
Adjustable line equaliser dB 0…18
0…18
Level adjuster dB 0…18
0…18
on the imput bi-directional
dB –20
–20
on the output directional
dB –20
–20
Operating voltage V~ 230 32 - 65
Power consumption W
14 14 (at 40 V)
A
-
3.5
in accordance with EN 60065 °C –20 … +55
–20 … +55
Functional in the temperature range
°C –40 … +60
–40 … +60
Weight kg approx. 2.0 approx. 2.0
Dimensions W x H x D mm 190 x 110 x 80
190 x 110 x 80
PG11 thread
PG11 thread
Test sockets internal F
Max. admissible current
of the remote feed Ambient temperature range
Housing
HF connectors 75 W
Line and distribution amplifiers for
implementation in CATV / installations
Local feed (GLV 865 AGC) or remote feed
GLV 865 F AGC:
Frequency range 862 MHz
AGC - automatic level control for
compensating attenuation fluctuations
in the cable network; total load control
47-320 MHz
Power doubler GaAs hybrid
Cascading up to 5 devices
With diplex modules individually configurable
Return channel optionally active with adjuster
for level and frequency-dependent line
attenuation
Level adjuster
Operating display LED, internal
Equalisation of frequency-dependent,
line attenuation, adjustable
GLV 865 F AGC: Remote feed via input, output or loop-through of the remote feed voltage
Internal F test sockets on the input and output
HF connections for PG 11 screw-fastening, adapters are available to F 5/8”, IEC M14 and 3.5/12
Diecast zinc housing, protection class IP 65
with screw terminal for equipopotential bonding
Satisfies EN 50083-3, quality class 2,
Note
• Diplex and return channel modules
are listed after the line/distribution
amplifiers • Compatible with standards
EN 60065, EN 50083-1,
EN 50083-2, Class A
EN 50083-3, quality class 2,
1) Basic
device without diplex module and without active return channel module
2) 42 channels
55
Amplifier
Modules for house connection amplifiers GPV... and line/distribution amplifiers GLV
Diplex modules
GRM 3047 P
GRM 6585 P
Order number
944 412-001
944 416-001
Frequency range
Return channel
MHz
5-30
5-65
MHz
47- 862
85-862
Return channel
dB
1
1
Forward channel
dB
1
1
dB
20 20
Additional versions are available
Forward channel / return channel dB
63
63
on request!
Environmental temperature range °C
–20 to +80
Return channel modules
GRM 3005 G
GRM 6505 G
Order number
944 411-001
944 419-001
Frequency range
MHz
5-30
5-65
Gain
dB
20
20
Frequency response
dB
1
1
Noise factor
dB
7
7
Forward channel
Diplex modules for house connection
amplifiers GPV...
Throughpass attenuation
and line/distribution amplifiers GLV ...
• Diplex modules passively distribute the
frequency range in return channel and forward channel
Return loss Decoupling between
Return channel amplifier modules for
house connection amplifiers GPV …
and Line/distribution amplifiers GLV ...
Output level
• Equaliser and level adjuster on the module IMA2 P 60 dB (EN 50083-3)
dBµV
110
110
input
IMA3 P 60 dB (EN 50083-5)
dBµV
118
118
• Use for high input level of the return Return loss on
dB
20
20
Adjustable line equaliser
dB
0-10
0-10
Level adjuster
dB
0-10
0-10
approx. 60 approx. 60
-20 to +80
–20 to +80
Return channel modules
GRM 2030 G
GRM 2065 G
Order number
944 414-002
944 420-002
Frequency range
MHz
5-30
5-65
Gain
dB
20
20
Frequency response
dB
1
1
Noise factor
dB
5
5
channels
RK/
RC
input and output
RK/
RC
Current consumption of the internal
Additional versions are available
operating voltage 24 V on request!
Environmental temperature range °C
Return channel amplifier modules for
house connection amplifiers GPV … and
Line/distribution amplifiers GLV ...
mA
Output level
• Equaliser and level adjuster on the module
IMA2 P 60 dB (EN 50083-3)
dBµV
108
105
- output
IMA3 P 60 dB (EN 50083-5)
dBµV
116
116
• Better signal/noise ratio for Return loss on
dB
20
20
Adjustable line equaliser
dB
0-10
0-10
Level adjuster
dB
0-10
0-10
RC input level below 90 dB
input and output
TP
RK/
RC
Additional versions are available
on request!
RK/
RC
Test socket return channel input dB
operating voltage 24 V mA
Environmental temperature range °C
56
–20
Current consumption of the internal
approx. 60 approx. 60
-20 to +80
–20 to +80
Remote feed power supply
Type
SWF 6530
Order number
947 592-001
SWF 6530
Operating voltage
Output voltage /
Output current, max.
Power consumption, max.
Operating conditions
Ambient temperature
Weight
Dimensions W x H x D
230 or 240 V~ (switchable)
50-60 Hz
42/ 50/ 58/ 65 V~ (switchable)
4.75/ 4.0/ 3.45/ 3.05 A
200 VA
-20°... +50°C
5.33 kg
170 x 188 x 85 mm
Line equaliser LES ...
Type
LES 450
LES 600
LES 860
Order number
947 558-001
947 559-001
947 560-001
Frequency range
Adjustable equalisation
Basic attenuation
(frequency-dependent)
Operating conditions
Dimensions W x H x D
47-450 MHz
18 dB
1 dB
47-606 MHz
18 dB
1 dB
47-862 MHz
18 dB
1 dB
48 x 44 x 24 mm
48 x 44 x 24 mm
48 x 44 x 24 mm
Accessories
Type
LES 2020 F
Order number
947 589-001
Frequency range
Throughpass attenuation
Max. remote feed current
40 MHz
21 dB
1 A / 24 V DC
940 MHz
12 dB 2150 MHz
2 dB
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
For supply of remote feed amplifiers in
distribution networks, such as the
– GPV series
– GLV series
4 selectable output voltages
Output: IEC screwed connection
M 14/1 (connector with cable in scope of delivery)
Control output: 4 mm round socket
Short-circuit proof through electronic
output fuse
Interior mounting on the wall
Power cord approx. 1.5 m with Shock-proof plug
Protection class 1, protection
class IP 65
Satisfies EN 60 065, EN 50083-1,-2
4 selectable output voltages
Output: IEC screw connection
M 14/1 (connector with cable in scope of delivery)
Control output: 4 mm round socket
Short-circuit proof through electronic
output fuse
Interior mounting on the wall
Power cord approx. 1.5 m with Shock-proof plug
Protection class 1, protection
class IP 65
Satisfies EN 60 065, EN 50083-1,-2
Accessories
• Remote feed coupler CA 1065-14 for 5/8” cable connector (to 1 GHz)
Order number 980 000-377
• Fitting 5/8 M-AC
Order number 980 000-391
Accessory for eco-power series
Line equaliser LES ...
• For compensating frequency dependent cable attenuation
• Slope adjustable in the respective frequency range
• HF connections with F connectors
and F-socket
• Can be screw-fastened to the house
connection amplifiers GHV 20 E and
GHV 30 E
• Metal housing
• Satisfies EN 50083-1, 2
•
Line equaliser 40-2150 MHz
• For compensating frequency dependent cable attenuation
• Use for example with amplifiers
CVE …
• With DC passthrough
• Adapter F-IEC (SBFC 01, see section Connectors), please order
separately
• HF connectors: F sockets
• Satisfies EN 50083-2
57
Amplifier
Terrestrial and SAT amplifier
CNV 11 F
•
•
•
•
•
•
•
•
Remote feed Post-amplifier terrestrial and
SAT signals
Remote feed of LNB´s
via the HF cable
For single antenna systems
with longer cable sections
One input, one output
Operating voltage of the LNBs
and of the post-amplifier is
provided by the receiver or by
the multiswitch
Line equaliser LES 2020 F for compensating the frequencydependent cable attenuation in
the distribution network at the
end of this section
Satisfies EN 50083-2
Type
CNV 11 F
CNV 235 E
Order number
947 764-001
947 643-002
47-862 MHz
Gain
Level attenuator
Line equaliser
Isolation IN / IN
Isolation OUT / OUT
Output level
Noise factor
Return loss on
Return loss off
950-2150 MHz
Gain
Level attenuator
Line equaliser
Isolation SAT in/in
Isolation SAT out/out
Isolation SAT on/out
Output level
CNV 235 E
•
•
•
•
•
•
Post-amplifier for
compensating the
attenuation losses in the
distribution network
Selective signal
amplification of the
terrestrial and two SAT
signals
Level adjuster -20 dB for each band
Line equalisers for each range.
Power supply via the DC input with
provided power pack
Satisfies EN 50083-1, 2
Noise factor
Return loss in
Return loss out
2150-2400 MHz
Gain
Isolation SAT in/in
Isolation SAT out/out
Isolation SAT on/out
Output level
Noise factor
Return loss in
Return loss out
Operating conditions
Remote feed voltage, current
Operating voltage
Current consumption
Power consumption
Weight
Dimensions
Operating voltage
Operating temperature
1) in
12 dB
5 dB
951 /1132 dBµV
29 dB
0...20 dB
0...20 dB
60-55 dB
20-18dB
1081 / 1182 dBµV
5 dB
5 dB
12 dB
12 dB
13-21 dB
36 dB
0...20 dB
0...20 dB
60 dB
55 dB
60 dB
1103 / 1214 dBµV
1033 / 1154 dBµV
6 dB
8 dB
10 dB
10 dB
20 dB
27 dB
55 dB
55 dB
55 dB
1073 / 1184 dBµV
1033 / 1134 dBµV
6 dB
8 dB
8 dB
max 450 mA
13-18V
35 mA
approx. 0.6 W
0.6 kg
80 x 44 x 25 mm
1.5 kg
285 x 115 x 70 mm
230V~/50-60Hz
-20°C to +60°C
accordance with EN 50083, Part 5 for interference products, second order at 60 dB IMA
accordance with EN 50083, Part 5 for interference products third order at 60 dB IMA
3) in accordance with EN 50083, Part 5 for interference products, second order at 35 dB IMA
4) in accordance with EN 50083, Part 5 for interference products third order at 35 dB IMA
All values with level adjuster on 0 dB and linear frequency response (equalisation 0 dB)
2) in
58
Multi-band amplifiers
Type
Order number
Number of inputs St. HMB 6
HMB 10A
HMB 10B
940 310-001 940 311-001 940 312-001
5
5
HMB 10S
940 313-001
6 8
Number of outputs St. 1
1
1 2
Number of channel filters
St.
6
6
10 10
Test socket St. no
1 (- 20 dB) Input BI/FM dB 24 48 48 45
Input BIII/DAB dB 35 48 48 45
Input HF and UHF (aux) dB 39 39 35
Input UHF 1 dB 48 55 55 50
Input UHF 2 dB 42 55 55 50
Input UHF 3 dB 30 55 50
Input SAT 1 dB 36-49 slope
Input SAT 2 dB 36-49 slope
Attenuation dB 1 (- 20 dB) 1 (- 20 dB)
Gain
Selectivity 0-20 dB / MHz 0-20 0-20 0-20
16/16 16/16 5.0 5.0 5.0
16/16, 40@862
Noise figure
VHF dB 9.0/3.0 DVB-T VHF dB 5.0 5.0 5.0
VHF and UHF (aux) dB 6.0 6.0 6.0
UHF dB 9.0 9.0 9.0
SAT dB 3.0/5.0/5.0 The programmable multi-band
amplifier HMB 10 is ideally suited
for implementation in a network
where many different signals
must be amplified and
distributed.
With just one device digital and
analog signals from up to 8
differently aligned terrestrial TV
and FM antennas or SAT
antennas can be actively
interconnected.
Additional equipment features:
• Very flexible thanks to 10
highly selective and adjustable
filters in the VHF range
• In the amplifier, integrated
easy programming.
Channels are programmed directly via the keypad and are
shown in the numeric display
• All settings can be transferred
to other amplifiers.
The programmed data can be
copied to off-the-shelf MMC/
SD memory cards and
imported into other amplifiers.
• Up to 8 inputs, depending
on type: FM, BIII, VHF/UHF
aux, 3 UHF inputs, 2 SAT
inputs
• Signal level
6.0
Output level (IMA3 /-60 dB/third order)
BI dBμV 103 124 124
118
BIII dBμV 108 124 124 118
VHF/UHF (aux) dBμV 124 124
118
UHF dBμV 124 124 118
SAT (-35 dB) dBμV 118
DC (pre-amplifier) V/mA 12 or 24/60
LNB supply V/mA kHz
0-22
112/115/112 General data
Power supply VAC/Hz Connections Impedance Ohm 12/50 12 or 24/60 12 or 24/60 230/50 230/50 230/50 F sockets F sockets F sockets 75
75 75 0/13/17/300
230/50
F sockets
75
59
Amplifier
Terrestrial multi-purpose amplifier 0.15-862 MHz
GNS 320 A
• For small to medium-sized MATV installations
Type
Order number GNS 320 A
944 652-001
GNS 440 A, GNS 445 A
• For medium-sized master
Power consumption
antenna installations
4 W
GNS 440 A
• Level adjuster 20 dB on each 470 174
862 230
87,5 MHz
108 MHz
Dimensions
200 x 105 x 63 mm
input except LMK
LMK FM
GNS 445 A
Frequency range
MHz
0.15-10
• Level adjuster 20 dB on all inputs
Gain dB
-
• External terminal + 24 V for remote feedstepped pre-switching devices (max. 60 mA)
Output level dBµV
-
BI BIII
BIV/V
87.5-108
47-68
174-230
470-862
20
-
20
20
109
1)
dBµV
109 2)
dB
7
Common features
Noise factor • For amplifying signals received from terres-
-
-
109
-
7
1)
109 1)
7
trial sources
• Implementation in receiving stations
• HF connectors: Coaxial sockets in accordance with IEC 60169-2
• Operating voltage 230 V~/50-60 Hz
Type
Order number GNS 440 A
944 655-001
• Metal/plastic housing
• Ambient temperature –20 °C to +50 °C
• Satisfies EN 50083-1, 2
•
470 174 47 0,15 MHz
862 230 68 108 MHz
Power consumption
4 W
Dimensions
200 x 105 x 63 mm
LMK FM
A new generation will be available in the
Frequency range
MHz
0.15-10
87.5-108
second half of 2007:
Gain dB
–1.5
27 T
- GNS 20 (GNS 320A)
Output level dBµV
-
109 1)
7
Order number 940,320-001
- GNS 30 (GNS 440A,GNS 445A)
Order number 940,321-001
Noise factor dBµV
109
dB
7
-
BI BIII
BIV/V
47-68
174-230
470-862
27 T
27 T
27 T
109 1)
109 1)
109 1))
7
7,5
2)
- GNS 35 (new)
Order number 940 322-001
Type
Order number GNS 445 A
944 652-001
470 174 47 0,15 MHz
862 230 68 108 MHz
Power consumption
min. 6.5 W/max. 8.5 W
Dimensions
200 x 105 x 63 mm
1)
In accordance with EN 50083-5, 66 dB IMA
LMK FM
if configured with 2 channels (interference
Frequency range
MHz
0.15-10
87.5-108
Gain dB
26 T
27 T
Output level dBµV
113 3)
109 1)
7
products third order)
2) In accordance with EN 50083-5, 60 dB (interference products second order)
3) For 66 dB harmonic distortion attenuation
(ak2 and ak3) at f = 260 kHz
All values with level adjuster T on 0 dB
60
Noise factor dBµV
109 2)
dB
7
-
BI BIII
BIV/V
47-68
174-230
470-862
27 T
27 T
27 T
109 1)
109 1) 109 1)
7
7.5
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF