AY-X14 Instruction Manual 140506

AY-X14 Instruction Manual 140506
05/06
Installation Instructions
WIRING INSTRUCTION
Model Series AY-H14/J14/K14/L14/M14
The AY-X14 Series Prox Readers are RFID proximity card reader to
be installed for use with access control systems.
AY-H14
AY-J14
AY-K14
AY-L14
AY-M14
These Installation Instructions contain the following information:
* Mounting Instructions
* Wiring Instructions
* Operation Instructions
The Prox Reader is supplied with an 18-inch pigtail, having a 6conductor cable. To connect the Reader to the Controller, perform
the following steps:
Model
Number
AY-H14
Output
Format
Clock/Data
Read Range
(Max.) *
12 cm
1. Prepare the Reader cable by cutting the cable jacket back 11/4
inches and strip the wires 1/2 inch.
2. Prepare the Controller cable by cutting the cable jacket back 11/4
inches and strip the wires 1/2 inch.
3. Splice the Reader pigtail wires to the corresponding Controller
wires and cover each connection (see Figure 2).
4. If the tamper output is being utilized, connect the purple wire to
the correct input on the Controller.
5. Trim and cover all conductors that are not used.
AY-J14
Clock/Data
10 cm
AY-K14
Clock/Data
8 cm
AY-L14
Clock/Data
12 cm
AY-M14
Clock/Data
10 cm
Figure 2 below shows how you should wire the Reader to the
Controller.
COLOR
CLOCK & DATA
OUTPUT
Red
Black
White
Green
Brown
Purple
DC+Input
Ground
Clock
Data
LED Control
Tamper
MOUNTING INSTRUCTION
Figure 1 shows the
front view of the Prox
Readers. When
mounting, the snap-off
cover must be removed
to access the screw
holes.
Rosslare
SNAP ON/OFF TOP COVER:
Remove to reveal screw holes
for mounting.
Figure 1
Mount the Reader with the appropriate screws (not supplied) as indicated
on the template
To mount the Reader, perform the following:
1. Determine an appropriate mounting position for the Reader.
2. Peel off the back of the self-stick mounting label template
included with the unit and place at the desired mounting position.
3. Using the template as a guide, drill two holes (hole size is
indicated on mounting template) for mounting the Reader to the
surface.
4. Drill a 7/16" (10mm) hole for the cable. If mounting on metal,
place a grommet or electrical tape around the edge of the hole.
5. Route the interface cable from the Reader to the Controller. A
linear type power supply is recommended.
NOTE: The Prox Reader can also be mounted using strong epoxy
glue. After application, the Reader should be firmly held in place
until the glue dries.
-1-
3. After the card data is processed by the Controller, the Controller
can then turn the LED green. Refer to the Controller description
of the LED operation if the Reader LED is controlled by the
Controller.
Figure 2
Cable Notes:
1. The individual wires coming out of the reader are color coded according
to the recommended Clock/Data standard.
2. When using a separate power supply for the Reader, this supply and the
Controller's power supply must have a common ground.
3. The cable shield wire on the Reader should be attached to an Earth
ground (best) or signal ground connection at the panel or power supply
end of the cable. This configuration is best for shielding the Reader
cable from external interference.
OPERATION INSTRUCTION
The Reader should be tested after wiring it to a power supply and the
Controller. Do this by performing the following steps:
1. Power up the Reader. The LED and Beeper will activate one time.
This indicates that the Reader is working properly.
2. Present the appropriate type of proximity card to the Reader. The
LED will momentarily flash green and a short beep will be
emitted. This indicates that the card was read properly by the Prox
Readers.
-2-
*
Table 1
Measured using Rosslare Proximity Card (P/N AT-R11, AT-T11)
or equivalent. Range also depends on electrical environment
and/or proximity to metal.
SPECIFICATIONS
Electrical Characteristics:
Power Supply Type
Operating Voltage Range
Maximum Input Current
Tamper Output
Maximum Cable Distance
to Controller
RF Modulation
Card Read Distance:
Regulatory Approvals:
Operating Temp. Range:
Operating Humidity:
Dimensions (mm):
AY-H14
AY-J14
AY-K14
AY-L14
AY-M14
Suitable for outdoor use
Linear type recommended
5 - 16 VDC
AY-K14
AY-J14
Standby : 35 mA
Read : 50 mA
AY-H14
AY-L14
AY-M14
Standby : 35 mA
Read : 100 mA
Open collector, active low,
max. sink current is 16 mA
150 meters (500 ft.)
ASK
See Table 1
USA : UL 294 & FCC Part 15B
Europe : CE Listed
-31oC to 63oC (25oF to 145oF)
0 to 95% (non condensing)
109.91 x 74.91 x 15.00
119.95 x 41.95 x 14.00
79.91 x 39.91 x 12.80
144.91 x 42.91 x 20.00
88.91 x 88.91 x 15.00
-3-
0706-0260014+01
Card Readers are to be used with control panels whose power
supply is UL Listed Class 2 or equivalent.