Heavy-Duty Range Match Gas Fryers

Heavy-Duty Range Match Gas Fryers
Item No. ___________________________
Project ___________________________
Heavy-Duty Range
Match Gas Fryers
Quantity ___________________________
MODEL GUIDE

Model No.
Overall Width
Tanks
Shortening
Capacity
RF40
18” (457mm)
1
40 lb (18 kg)
RF240
36” (914mm)
2
80 lb (36 kg)
RD18
18” (457mm)
Basket Drain Cabinet
BURNERS & CONTROLS:
•Stainless steel atmospheric 55,000 BTU/hr burners
•Self-powered 200-375°F (93-190°C) thermostat-gas valve
•Automatic ignition safety pilot
•High temp limit control & built-in gas pressure regulator
RD18 DRAIN CABINET [ONLY]
•Matching cabinet with hinged door
•Stainless steel perforated lift out top screen
•Stainless steel slide-out grease catch pan
AGENCY APPROVALS:
•NSF Listed
•ETL Design Certified to ANSI Z83.11 • CSA 1.8
•CE Approved • EN 203-1
Model RF40
SHORT/BID SPECIFICATION
Fryer shall be a Montague Legend Range Match Model [Specify one]:
M RF40, an 18” (457mm) wide unit with a unique 110,000 BTU/hr
burner and a single 40 pound oil capacity frypot
M RF240, a 36” (914mm) wide unit with two 110,000 BTU/hr
burners with twin 40 pound oil capacity frypots
M RD18, an 18” (457mm) wide matching fry basket drain cabinet;
…with satin finished stainless steel front, cabinet access door(s),
bottom and sides; two 5-1/2” (140mm) wide fry baskets per frypot and
removable stainless steel basket hangers; 6” (152mm) height adjustable legs and 11” (279mm) high flue riser standard; plus all the features
listed and options/accessories checked:
STANDARD CONSTRUCTION FEATURES:
•Satin finish stainless steel front, sides & bottom
•Hinged stainless steel door(s) provides easy access to controls
•Other surfaces painted black
•Welded stainless steel frypot with deep cool zone
•1” (25mm) ball-type front drain valve, with extension pipe standard
•Twin wire fry baskets with insulated handles
•Sturdy, removable, stainless steel basket hangers
•11” (279mm) high flue riser with insulated heat shield for cooler
operation
•6” (152mm) height-adjustable stainless steel legs
•1-1/4” NPT front gas manifold with 1/2 unions for battery connection
HDS-47 [Rev. 1/12]
THE MONTAGUE COMPANY • 1830 Stearman Avenue, Hayward, CA 94545 • 800 345-1830 • Fax: 510 785-3342 • montaguecompany.com
Item No. ___________________________
Heavy-Duty Range Match
Project ___________________________
Gas Fryers
Quantity ___________________________
Gas Fryers
Dimensions in brackets are millimeters
OPTIONS GUIDE:
General:
M E xtra baskets, Twin: ___ ea.
M E xtra baskets, Triple: ___ [set of three]
M S ide Splash 8” (203mm) high [for left or right]
M S tainless steel back panel
M 1 8” (457mm) high-back flue riser
M I nset covers, stainless steel: ___ ea. [frypot]
M P ortable filtering system [for use with RD18]
M Flanged feet with holes
Special finish: [Consult factory]
International Approvals:
M CE - Conformite Europeenne - EN203-1 Includes flame failure valve option
M Canadian Approval
Manifolds: [Left rear with pressure regulator]:
M 1 ” NPT up to 500,000BTU/hr
Manifold Cap: M left side M right side
Stainless Manifold Cover:
M left side M right side
INSTALLATION REQUIREMENTS & SHIPPING INFORMATION
1. Fryers must be installed in accordance with local codes or in their absence with the
National Fuel Gas Code: ANSI Z223.1; Natural Fuel Gas Code: CAN/CGA-B149.1 or Propane
Installation Code: CAN/CGA-B149.2, as applicable. Compliance with codes is the
responsibility of the Owner and Installer.
2. An adequate ventilation system is required. Refer to National Fire Protection Association
Standard No. 96, “Vapor Removal from Cooking Equipment.”
3. This appliance is intended for commercial use by professionally trained personnel.
NOT intended for Residential Use.
4. Specify installation elevation: _____________ if above 2,000 ft(610m).
5. GAS INLET SIZE (All Models): 1-1/4 NPT front manifold with 1/2 union on each end
provided for battery connection. A properly sized gas pressure regulator must be furnished
by the Installer.
6. The incoming gas line pressure into the regulator should be 8”-14” w.c. for natural gas,
and 12”-14” w.c. for propane gas.
Specify Type of Gas:
Manifold Pressure:
Burners
Models:
RF40
RF240
RD18
*Total BTU Input/firing rate
1
2
M Natural
4.0” WC
BTU/hr* (kW)
110,000(32.2)
220,000(64.4)
M Propane
10.0” WC
BTU/hr* (kW)
110,000(32.2)
220,000(64.4)
Minimum
Clearances
Combustible
Construction
Noncombustible
Construction
NA
6” (381mm)
6” (152mm)
0”
From Back Wall
Left & Right Side
Suitable for installation
on combustible floors
With 6” (152mm) legs
Shipping
Weight
Shipping
Class
Cube
(Crated)
ft3/m3
251 lbs (114 kg)
423 lbs (192 kg)
238 lbs (108 kg)
85
85
85
18/.5
36/1.0
15/.4
RF240 Entry Clearance: 36-1/8” (918mm) uncrated.
Due to continuous product improvements,
specifications are subject to change without notice.
1830 Stearman Avenue, Hayward, CA 94545
800 345-1830 • Fax: 510 785-3342
www.montaguecompany.com
HDS-47 [Rev. 1/12]