Digital RTD Thermometer 316 SS Enclosure for Wash

Digital RTD Thermometer 316 SS Enclosure for Wash
Digital RTD Thermometer
316 SS Enclosure for Wash-Down
and Marine Applications
Antenna
connection for
wireless option.
DTG-RTD100 Series
Optional
U Large Multicolor Backlit
Display with 25 mm (1")
Digits Readable From
Over 10.7 m (35')
U Up to ±0.2°C (±0.3°F) or
±0.1% Rdg Accuracy
U Connects Directly to
3‑Wire Pt100 RTD Sensors
U User Scaleable 4 to 20 mA,
0 to 5 or 0 to 10 Vdc
Analog Output Standard
U Powered by Internal
Battery or External DC
Power Supply
U Included Setup and
Service Software Allows
for Fast Maintenance
and Calibration via USB
Connection
U Wireless Transmitter
Option Sends Readings
to Remote Locations and
Allows for PC-Based
Chart Recording and
Data Logging
U Low Power Operation
and Sleep Mode for
Long Battery Life
U Display Backlight
Changes from Green to
Blue for Low Alarm and
from Green to Red for
High Alarm
OMEGA’s new DTG‑RTD100
Thermometer Series features a
rugged 316 SS enclosure that is
designed specifically for wash-down
and marine applications. The large
backlit LCD display incorporates
both large 25 mm (1") digits and a
25 segment bar graph that make
m
Large 25 m
s
(1") Digit
Magnetic
stylus
(included).
DTG-RTD100-1/4-600-E-W-AB
with angle bracket and
wireless transmitter option,
shown actual size.
New security feature uses
magnetic stylus (included) for
keypad activation. No accidental
button presses. Perfect for dirty
hands or if wearing gloves
Availa
Built-In ble with
Transm Wireless
itter Op
tion
Angle B
ra
Option cket
Flexible for
Use
reading at distances up to 10.7 m
(35') easy. Models are available with
or without integral standard sensors.
Standard features include: internal
battery external DC power supply
operation, analog output and user
programmable alarms. The wireless
transmitter option allows for remote
N-5
monitoring, chart recording
and data logging. A variety of
user-configurable options and
settings include: sample interval,
units and backlight.
Specifications
Range: -51 to 538°C (-60 to 1000°F)
(depending on sensor selected)
Accuracy: ±0.2°C (±0.3°F) or ±0.1%
of reading
Resolution: 0.1°C (0.1°F)
Operating Environment: -40 to 70°C
(-40 to 158°F) 5 to 100% RH
non-condensing
RTD Probe/Sensor Input: Pt100,
3-wire
Display Type: LCD with selectable
backlight
Display Digits: 4 digits, 9999 counts
Character Height: 25.4 mm (1.0")
Computer Interface: USB (one
programming cable included)
Sample/Display Interval:
User adjustable from 0.375 to
30 seconds, preset to 1/second
Power: 3.6V lithium, 8.5 Ah capacity
(“C” cell) included; 12 to 24 Vdc
Battery Life (Typical): 1 year*
Analog Output: User selectable
0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA;
Requires external 12 to 24 Vdc power
supply for operation
Enclosure: 316 stainless steel housing,
ABS center gasket
Enclosure Finish: Brushed 316
stainless steel
Enclosure Rating: NEMA 4X (IP65)
Settings (USB/Software)
Units: °F, °C, K
Alarms: User selectable “high” and
“low” alarm limits
Analog Output: User selectable scaling
Backlight: On/off, or 10 second, 30
second, 1 minute, 5 minute
Wireless Transmitter (Optional):
Channel number, transmission rate,
alarms, sensor offset, chart recording,
data logging
Dimensions:
115.1 H* x 114.8 W x 74.2 mm D
(4.53* x 4.52 x 2.92")
(*height not including sensor)
Weight: 0.72 kg (1.59 lb)
Wireless Option
Specifications
Transmit Sample Rate:
User programmable from 1 sample/
2 minutes to 1 sample/every 2 seconds
Radio Frequency (RF) Transceiver
Carrier: ISM 2.4 GHz
RF Output Power: 10 dBm (10 mW)
Range of RF Link:
Outdoor Line of Sight:
Up to 120 m (400')
Indoor/Urban: Up to 40 m (130')
Software (Included Free): Requires
Windows® XP/Vista/7 (32- and 64-bit)
Internal Battery: Two 3.6V lithium,
8.5 Ah capacity (“C” cell) included
Data Transmitted to Host:
Temperature reading, ambient
temperature reading, RF transmit
strength and battery level
Wireless
Receivers
UWTC-REC4
receiver
Receive data from
up to 48 transmitters,
and provide a scalable
retransmitted, hard
wired analog output
for 4 user selected
transmitters in your
system.
UWTC-REC1
* Without wireless option
Read From Up to 10.7 m (35') Away!
Large 25 mm
(1") Digits
Receive data from up to
48 transmitters, powered directly
by the USB connection on your
computer.
UWTC-REC2-D with
analog output and display.
Temperature
Units (°C/°F)
25 Segment
Bargraph
Low Alarm Backlight
High Alarm Backlight
N-6
Receiver/host with ethernet is
compatible with UWTC and UWRTD
connectors, transmitters and wireless
probe assemblies. Connects directly to
your network or the Internet—
no PC required!
N
Digital RTD Thermometer for
use with Remote Sensor
Optional
Mounting B Wall
rack
Available et
Remote Sensor Options
3A approved, ⁄4" diameter standard duty
design, Pt100 sensor with M12 male
connector, stainless steel construction
and 11⁄2" 16AMP cap, standard lengths
from 3 to 6". Temperature range
-50 to 200°C (-58 to 392°F).
1
®
Probe sold separately.
74-05
Ordering Example: DTG-RTD100-M12-F-1,
thermometer with female M12 connection,
PRS-3-100-A-S-0600-D1-M12, 6" standard
duty sensor, and M12-PVC-4-S-M-R-F-5, cable,
PVC jacket, 5 m (16.4') long.
3A approved, 3⁄8" diameter (stepped to 3⁄16"),
heavy-duty design, Pt100 sensor with M12
male connector, stainless steel construction
and 11⁄2" 16AMP cap, standard lengths from
3 to 6". Temperature range -50 to 200°C
(-58 to 392°F).
DTG-RTD100-M12-M
shown smaller than
actual size.
Female model (-F)
recommended for
washdown applications.
®
Probe sold separately.
74-05
Ordering Example: DTG-RTD100-M12-F-1, thermometer
with M12 female connection, PRS-3-100-A-H-0600-D1-M12,
6" heavy-duty sensor, and M12-PVC-4-S-M-R-F-5, cable,
PVC jacket, 5 m (16.4') long.
General purpose
M12 style cable with
stripped leads and
additional mating
M12 field installable
connector included.
Optional Cables with M12C Connectors for
Remote Sensor Connection
1
⁄8" or 1⁄4" diameter, industrial sensor 316 stainless steel
construction, 1⁄2 NPT with M12 connector.
Temperature range -50 to 260°C (-58 to 500°F).
Rugged PVC jacketed
cables for wash-down
applications.
Probe sold separately.
316 SS nut.
Ordering Example: DTG-RTD100-M12-F-1, thermometer
with M12 female connection PR-21B-3-100-A-1/4-0600-M12,
6" industrial sensor, and M12-PVC-4-S-M-R-F-S, cable,
PVC jacket, 5 m (16.4') long.
M12C-PVC-4-S-M-R-F-2 with
right angle male and female
connectors.
M12C-PVC-4-S-M-S-F-2, with
straight male and female
connectors.
Typical Multi-Unit Wireless Data Logging System
Up to
DTG-RTD100,
remote sensor
model shown.
122 m
(400')
DTG-RTD100
shown
with M12
probe, sold
separately.
DTG-RTD100 shown
with integral industrial
probe and angle
bracket option.
N-7
Shown smaller
than actual size.
UWTC-REC1
USB receiver.
Laptop not included.
Digital RTD Thermometer
as an Integral Sensor
Antenna connection
for wireless option.
Magnetic
stylus
(included).
Purchase the DTG-100 with
a 1⁄8 or 1⁄4" diameter industrial
sensor attached or use
the DTG-RTD100-M12-F
configuration to affix any M12
style probe.
Integral
sensor.
DTG-RTD100-M12-F with
PR-21B-3-100-A-1/4-0600-M12
sensor, sold separately, shown
smaller than actual size.
Integral
sensor.
DTG-RTD100-1/4-600-E-W,
sensor included, shown
smaller than actual size.
Thermowell Options for Industrial Sensors
1
⁄8" or 1⁄4" dia, industrial sensor,
316 stainless steel construction,
and 1⁄2 x 1⁄2 NPT fitting, temperature
range -51 to 538°C (-60 to 1000°F).
Standard 304 or 316 stainless steel models–260L Series
Ordering Example:
DTG-RTD100-1/4-400-E, comes
complete with thermometer
and 4" L integral sensor.
®
3A approved 316 stainless steel models–S Series.
Universal Angle
Bracket Option
Wireless Models Include FREE Monitoring,
Charting and Data Logging Software
For Your PC!
Ordering Example: DTG-RTD100-1/4-400-E-AB, field
adjustable bracket allows sensor to be rotated and angled.
N-8
N
Thermometer without Sensor
To Order
Model No.
Description
DTG-RTD100 Digital RTD thermometer with internal terminal block connection
DTG-RTD100-M12-F Digital RTD thermometer with female M12 connection, compatible with PR-21,
-2 wiring, PR-22
DTG-RTD100-M12-F-1 Digital RTD thermometer with female M12 connection, compatible with PR-21,
-1 wiring, PRS-M12 and PR-25AP sensors
DTG-RTD100-M12-M
Digital RTD thermometer with male M12 connection, for use with extension cable
and compatible sensor
DTG-RTD100-M12-M-1
Digital RTD thermometer with male M12 connection, for use with extension cable
and compatible sensor
Thermometer with Integral Sensors
Model No.
Description
DTG-RTD100-1/8-(*)-E Digital RTD thermometer with integral 1⁄8" diameter standard duty Pt100 sensor
DTG-RTD100-1/4-(*)-E Digital RTD thermometer with integral 1⁄4" diameter standard duty Pt100 sensor
Accessories
Model No.
Description
DTG-RTD100-MB Mounting bracket (not needed for models with intregral sensor)
DTG-RTD100-SK Service kit, includes enclosure lid, clear window, gasket, washers, screws
DTG-MS
Spare magnetic programming stylus (2 pack)
BATT-C-3.6V
Replacement battery, “C” cell 3.6V lithium (2 required with wireless option)
UWTC-REC1
Wireless 48-channel USB receiver (used with wireless option only)
UWTC-REC2-D-(*) 48-channel transmitter receiver with analog output and digital display
UWTC-REC4-(**)48-channel din rail wireless receiver with 4 analog outputs and alarms
CAL-3
NIST-traceable calibration (meter only)
CAL-3-SYSTEM
NIST-traceable calibration (meter with probe)
Comes complete with operator’s manual, USB cable, user software, magnetic programming stylus and 3.6V lithium “C” cell battery.
* Specify probe length; “300” for 3", “400” for 4", “500” for 5", or “600” for 6".
** Specify analog output signal: “V1” for 0 to 5 Vdc; “V2” for 0 to 10 Vdc, “TC” for Type K thermocouple, or “MA” for 4 to 20 mA signal.
To order with angle bracket option, add suffix “-AB” to model number for additional cost.
To order with wireless transmitter option, add suffix “-W” to model number for additional cost.
Note: Units with the wireless option require a UWTC series receiver or transceiver to operate.
Ordering Examples: DTG-RTD100-1/4-600-E-W-AB, RTD meter with integral Pt100, 6" long, 1⁄4" diameter industrial probe with angle bracket
and wireless options, and UWTC-REC1, 48-channel USB receiver.
DTG-RTD100-M12-M, RTD meter with male M12 connector.
N-9
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF