- Industrial & lab equipment
- Measuring, testing & control
- Futek
- CSG110 Series
- Quick start Guide
- 2 Pages
Futek CSG110 Series Quick Start Guide
Futek CSG110 Series is a versatile amplifier designed for use with various sensors, including load cells, torque sensors, and pressure sensors. It offers a wide range of features, including adjustable input range, current output selection, span and zero trimming, and shunt calibration. With its compact size and easy-to-use interface, the CSG110 is ideal for a wide variety of applications, including industrial automation, test and measurement, and medical equipment.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
CSG110 (JM-2A) AMPLIFIER Quick Start Input Range Jumpers FRONT Polarity Selection Reverse Polarity Default BACK D The default polarity is shown in the picture on the left. To reverse the polarity, simply move the jumpers to the positions shown on the right. The input value range is from 0.5 to 4.0 mV/V (based on 10VDC excitation). Select the input value closest to your input range by soldering the corresponding jumper. Span trim maybe required in some cases. D Current Output Selection To change the current output, solder the jumper in the fashion described in the table below: mA Output SJ1 SJ2 SJ3 4-20mA (Default) Closed Open Open 0-20mA Open Closed Open 5-25mA Closed Open Closed Female Connector (Sensor) D : Default setting. Male Connector (Output/Power) Shunt Pin# Wiring Code 1 + Excitation 2 + Signal 3 - Signal 4 - Excitation * NOTE: For 6-wire connections, jumper the Sense wires with the Excitation wires. Span Trimming Adjust: Zero Shift: Causes positive or negative zero shift for a bi-directional single ended voltage setup. Eg. 4-20mA Where 12mA is ZERO LOAD. For more info, visit: http://www.futek.com/jm.asp www.futek.com D Needed when sensor sensitivity QHHGVWREHDGMXVWHGWRDVSHFL¿F output to meet CSG signal requirements. Eg. 2.850mV/V to 2.000mV/ V. Note that Exitation Through (ETR) jumper must be open to use these options. Shunt Resistor Excitation Jumpers The shunt resistor is attached in the location marked ‘RSH’ (shown above). To change the resistance value, simply solder your desired resistor into the ‘RSH’ location. There are two excitation values available on the CSG, 10 VDC (default) and 5 VDC. To select your excitation, simply connect the corresponding jumper. Tel: 1-800-23-FUTEK or 949-465-0900 * NOTE: Only one excitation jumper can be connected at the same time. [email protected] It is NOT necessary to open the &6*DPSOL¿HU to activate the shunt feature. Pin# Simply press the button 9 through the cover in the 8 location marked ‘SHUNT’. Span Adjust Zero Adjust Adjustments to the Span and Zero are made by using a ¿QHSLWFKVFUHZGULYHUWRDGjust the Span and Zero pots. Wiring Code Color Code +12 to 24 VDC (Power) Red Voltage Out (VDC) Green 7 Voltage Return (VDC) Orange 6 Ground (Power) Black 2 Current Return (mA) Blue 1 Current Out (mA) White * NOTE: Power supply requires 12-24 VDC at 150 mA (min.). 4-20 mA signal out requires positive sensor signal polarity. Copyright 2006 Futek Advanced Sensor Technology, Inc. Doc. No. MKTSFCSG12012006 CSG110 (JM-2A) AMPLIFIER Quick Start PACKAGE Backside Standard CSG110 Package Male DB9 Connector Terminal Board w/ Male DB9 Connector (FSH01077) connector LOAD CELL & FORCE SENSOR connector TORQUE SENSOR Signal Out SETUP 2 Power & DMM connector Computer Futek VCal Sensor 4 3 and chosen output (Options available: VDC or 4-20 mA, 5 or 10 VDC excitation, and shunt cal calibration). able online at www.futek.com. 4. System calibration is VOID if SPAN is adjusted after shipment. 5 Connect power Connect to display Internal label for convenience * There are slots on each side of the CSG110 ampli- Span & Zero Turn the screws. CCW to increase SPAN and CW to increase ZERO www.futek.com LSB S-Beam Load Cell completed by factory. READY TO USE. How to Open the Case * Span potentiometer locked on system calibrations. Power & DMM Power & DMM Futek IPM500 Digital Display Plug in DB9 female connector How to Adjust Span & Zero, and Activate Shunt (Standard) LCB500 Universal Load Cell A to D Card PRESSURE SENSOR Plug in DB9 male connector LTH300 Load Cell connector CSG110 (FSH02439) System Calibration Scope or DMM connector 1 (FSH02237) +12 to +24 VDC power ONLY Power Supply Power Male DB9 Connector w/ Bendix Connector and Cable Assembly Terminal Board w/ Female DB9 Connector (FSH02236) (FSH01449) SYSTEM Male DB9 Connector w/ Lemo Connector and Cable Assembly (FSH01481) Female DB9 Connector w/ Cable Assembly CSG110 (FSH01075) ACCESSORY Din Rail Mounting Tel: 1-800-23-FUTEK or 949-465-0900 Shunt Press shunt button and hold. [email protected] easy opening. Slot You can use a screwdriver to open the case. Copyright 2006 Futek Advanced Sensor Technology, Inc. Doc. No. MKTSFCSG12012006
advertisement