Futek CSG110 Series Quick Start Guide

Futek CSG110 Series Quick Start Guide

Futek CSG110 Series is a versatile amplifier designed for use with various sensors, including load cells, torque sensors, and pressure sensors. It offers a wide range of features, including adjustable input range, current output selection, span and zero trimming, and shunt calibration. With its compact size and easy-to-use interface, the CSG110 is ideal for a wide variety of applications, including industrial automation, test and measurement, and medical equipment.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Futek CSG110 Series Quick Start Guide | Manualzz
CSG110 (JM-2A) AMPLIFIER Quick Start
Input Range Jumpers
FRONT
Polarity Selection
Reverse
Polarity
Default
BACK
D
The default polarity is shown in the picture on
the left. To reverse the polarity, simply move the
jumpers to the positions shown on the right.
The input value range is from 0.5 to 4.0 mV/V
(based on 10VDC excitation). Select the input
value closest to your input range by soldering the
corresponding jumper. Span trim maybe required
in some cases.
D
Current Output Selection
To change the current output, solder the jumper
in the fashion described in the table below:
mA Output
SJ1
SJ2
SJ3
4-20mA (Default)
Closed
Open
Open
0-20mA
Open
Closed
Open
5-25mA
Closed
Open
Closed
Female Connector
(Sensor)
D
: Default setting.
Male Connector
(Output/Power)
Shunt
Pin#
Wiring Code
1
+ Excitation
2
+ Signal
3
- Signal
4
- Excitation
* NOTE: For
6-wire connections, jumper
the Sense
wires with the
Excitation
wires.
Span Trimming Adjust:
Zero Shift:
Causes positive or negative zero
shift for a bi-directional single ended
voltage setup. Eg. 4-20mA Where
12mA is ZERO LOAD.
For more info, visit:
http://www.futek.com/jm.asp
www.futek.com
D
Needed when sensor sensitivity
QHHGVWREHDGMXVWHGWRDVSHFL¿F
output to meet CSG signal requirements. Eg. 2.850mV/V to 2.000mV/
V. Note that Exitation Through
(ETR) jumper must be open to use
these options.
Shunt Resistor
Excitation Jumpers
The shunt resistor is attached in the
location marked ‘RSH’ (shown above).
To change the resistance value, simply
solder your desired resistor into the
‘RSH’ location.
There are two excitation values available on the CSG, 10 VDC (default) and
5 VDC. To select your excitation, simply
connect the corresponding jumper.
Tel: 1-800-23-FUTEK or 949-465-0900
* NOTE: Only one excitation jumper can be connected at the same time.
[email protected]
It is NOT necessary to open the
&6*DPSOL¿HU
to activate the
shunt feature.
Pin#
Simply press
the button
9
through the
cover in the
8
location marked
‘SHUNT’.
Span Adjust
Zero Adjust
Adjustments to the Span and
Zero are made by using a
¿QHSLWFKVFUHZGULYHUWRDGjust the Span and Zero pots.
Wiring Code
Color
Code
+12 to 24 VDC
(Power)
Red
Voltage Out
(VDC)
Green
7
Voltage Return
(VDC)
Orange
6
Ground (Power)
Black
2
Current Return
(mA)
Blue
1
Current Out (mA)
White
* NOTE: Power supply requires 12-24
VDC at 150 mA (min.). 4-20 mA signal out
requires positive sensor signal polarity.
Copyright 2006 Futek Advanced Sensor Technology, Inc.
Doc. No. MKTSFCSG12012006
CSG110 (JM-2A) AMPLIFIER Quick Start
PACKAGE
Backside
Standard
CSG110
Package
Male DB9
Connector
Terminal Board
w/ Male DB9
Connector
(FSH01077)
connector
LOAD
CELL
&
FORCE
SENSOR
connector
TORQUE
SENSOR
Signal
Out
SETUP
2
Power
&
DMM
connector
Computer
Futek VCal Sensor
4
3
and chosen output (Options available: VDC or 4-20 mA, 5
or 10 VDC excitation, and shunt cal calibration).
able online at www.futek.com.
4. System calibration is VOID if SPAN is adjusted after
shipment.
5
Connect power
Connect to display
Internal label for
convenience
* There are
slots on each
side of the
CSG110 ampli-
Span & Zero
Turn the screws. CCW to increase SPAN and CW to increase ZERO
www.futek.com
LSB
S-Beam
Load Cell
completed by factory. READY TO USE.
How to
Open the
Case
* Span potentiometer locked
on system
calibrations.
Power
&
DMM
Power
&
DMM
Futek IPM500
Digital Display
Plug in DB9 female connector
How to
Adjust
Span &
Zero, and
Activate
Shunt
(Standard)
LCB500
Universal
Load Cell
A to D Card
PRESSURE
SENSOR
Plug in DB9 male connector
LTH300
Load Cell
connector
CSG110
(FSH02439)
System Calibration
Scope or DMM
connector
1
(FSH02237)
+12 to +24
VDC power
ONLY
Power Supply
Power
Male DB9
Connector w/
Bendix Connector and Cable
Assembly
Terminal Board w/
Female DB9
Connector
(FSH02236)
(FSH01449)
SYSTEM
Male DB9
Connector w/
Lemo Connector and Cable
Assembly
(FSH01481)
Female DB9
Connector
w/ Cable
Assembly
CSG110
(FSH01075)
ACCESSORY
Din Rail
Mounting
Tel: 1-800-23-FUTEK or 949-465-0900
Shunt
Press shunt button and hold.
[email protected]
easy opening.
Slot
You can use a screwdriver to open the case.
Copyright 2006 Futek Advanced Sensor Technology, Inc.
Doc. No. MKTSFCSG12012006

advertisement

Related manuals

Download PDF

advertisement