Topaz Signature Pad Installation Instructions

Topaz Signature Pad Installation Instructions
ADL Optimum Series
Topaz Signature Pad Installation Instructions
Topaz Signature Pad Installation Instructions
© 2010 ADL Data Systems, Inc. All Rights Reserved
ADL Optimum Series
Topaz Signature Pad Installation Instructions
Table of Contents
Getting Started ................................................................................................................ 1
Installation – On Client PC........................................................................................... 2
Installation - Using Terminal Server or Citrix ............................................................. 10
© 2010 ADL Data Systems, Inc. All Rights Reserved
iii
ADL Optimum Series
Topaz Signature Pad Installation Instructions
Getting Started
The SigPlus electronic signature software allows for versatile signature-capture operation with Windows
operating systems 95 and greater. These instructions were written and tested with sigplus.exe version
3.95 and sigsockinstall.exe version 3.97.
DO NOT connect the device until the software is installed. To connect the device, simply insert the USB
plug into the USB port specified during the installation. The device is hot-pluggable and may be
connected and removed without restarting the host computer. When connected properly, the LCD screen
will briefly display a “waterfall” of pixels to verify that it is operable.
USB connectivity is the only supported connection type and SigLite LCD 1X5 (T-L460) is the only
supported tablet device model recognized by ADL Optimum Series software.
© 2010 ADL Data Systems, Inc. All Rights Reserved
1
ADL Optimum Series
Topaz Signature Pad Installation Instructions
Installation – On Client PC
1. Open the folder in which sigplus.exe is located. Usually this is D:\adl3\ in an MS SQL
environment or D:\adl2\ in an Oracle environment, where D is the root drive where ADL
applications are installed.
2. Start the installation program by double clicking sigplus.exe. The Welcome screen is displayed.
3. Close any open Windows programs and click the Next button.
© 2010 ADL Data Systems, Inc. All Rights Reserved
2
ADL Optimum Series
Topaz Signature Pad Installation Instructions
4. Read the information displayed in the Read Me File window. Click the Next button when finished.
5. Use the Browse button in the Choose Destination Location window to specify a folder where
the Topaz software will be installed. Click the Next button when finished.
© 2010 ADL Data Systems, Inc. All Rights Reserved
3
ADL Optimum Series
Topaz Signature Pad Installation Instructions
6. In the SigPlus Install window, select the radio button applicable to the operating system you are
using. Click the OK button when finished.
7. In the Choose the Tablet window, select the SigLite LCD 1X5 (T-L460) radio button. SigLite
LCD 1X5 (T-L460) is the only supported tablet device model recognized by ADL Optimum Series
software. Click the OK button when finished.
© 2010 ADL Data Systems, Inc. All Rights Reserved
4
ADL Optimum Series
Topaz Signature Pad Installation Instructions
8. In the Set the Connection Type window, select the HSB (USB type) radio button. USB
connectivity is the only supported connection type recognized by ADL Optimum Series software.
Click the OK button when finished.
9. The HSB Tablet Message displays and serves as a reminder that you must unplug the tablet
device. Unplug the device if it is plugged in and click OK.
© 2010 ADL Data Systems, Inc. All Rights Reserved
5
ADL Optimum Series
Topaz Signature Pad Installation Instructions
10. Read the License Agreement. You must agree to the terms in order to install the software. Click
Agree after reading the agreement.
11. The progress of the installation is displayed in the Installing window. The window closes
automatically after all files have been copied.
© 2010 ADL Data Systems, Inc. All Rights Reserved
6
ADL Optimum Series
Topaz Signature Pad Installation Instructions
12. As an option, you can choose to have the installation place a shortcut on the desktop to the
DemoOcx.exe. Click the radio button of your choice and then click OK.
13. A confirmation message indicating the directory where the installation notes and setup
documentation can be found is displayed. Click OK.
© 2010 ADL Data Systems, Inc. All Rights Reserved
7
ADL Optimum Series
Topaz Signature Pad Installation Instructions
14. Topaz advertisement information displays. Click OK.
15. The HSB Support dialog displays and serves as a reminder that when the installation finishes
and you plug in your device, the drivers will automatically load. Click OK.
© 2010 ADL Data Systems, Inc. All Rights Reserved
8
ADL Optimum Series
Topaz Signature Pad Installation Instructions
16. Confirmation that the Topaz e-Signature SigPlus software was successfully installed is displayed
in the Installation Complete window. Click the Finish button to exit the installation.
© 2010 ADL Data Systems, Inc. All Rights Reserved
9
ADL Optimum Series
Topaz Signature Pad Installation Instructions
Installation - Using Terminal Server or Citrix
The SigSock system allows a Topaz HID USB (“HSB”) signature pad to be used in a thin client
environment (Terminal Server 2003 RDP session or Citrix session) by utilizing a socket to pass the data
from the client machine to the waiting SigPlus-based application on the server. This SigSock version
requires that the client machine is a Windows fat client (running a full version of Windows such as 2000,
XP, or equivalent). Thin client terminals (such as Wyse terminals) running XPe or “thin” operating systems
are not covered in the document and version of SigSock. In order for the SigSock system to function, you
must be using the SigPlus.ocx version 3.89 or greater.
In general terms, the following steps will need to take place to ensure successful implementation.
•
•
•
Install the latest version of SigPlus for SigSock to the server.
Copy the SigPlus.ini file from the server to each user’s local Windows directories. (Check that
TabletType=7 is set, and that the TabletPortPath parameter matches the clientname used in the
call to the SigSock.exe)
Copy the SigSock.exe to the client, ensuring that it is called with the proper parameters before
running the SigPlus application on the client.
Specifically, do the following:
1. Open the folder in which sigsockinstall.exe is located. Usually this is D:\adl3\ in an MS SQL
environment or D:\adl2\ in an Oracle environment, where D is the root drive where ADL
applications are installed.
2. Start the installation program by double clicking sigsockinstall.exe.
© 2010 ADL Data Systems, Inc. All Rights Reserved
10
ADL Optimum Series
Topaz Signature Pad Installation Instructions
3. Close any open Windows programs and click the Next button.
4. Read the information displayed in the Read Me File window. Click the Next button when finished.
5. Use the Browse button in the Choose Destination Location window to specify a folder where
the Topaz SigSock software will be installed. Click the Next button when finished.
© 2010 ADL Data Systems, Inc. All Rights Reserved
11
ADL Optimum Series
Topaz Signature Pad Installation Instructions
© 2010 ADL Data Systems, Inc. All Rights Reserved
12
ADL Optimum Series
Topaz Signature Pad Installation Instructions
© 2010 ADL Data Systems, Inc. All Rights Reserved
13
ADL Optimum Series
Topaz Signature Pad Installation Instructions
© 2010 ADL Data Systems, Inc. All Rights Reserved
14
ADL Optimum Series
Topaz Signature Pad Installation Instructions
© 2010 ADL Data Systems, Inc. All Rights Reserved
15
ADL Optimum Series
Topaz Signature Pad Installation Instructions
© 2010 ADL Data Systems, Inc. All Rights Reserved
16
ADL Optimum Series
Topaz Signature Pad Installation Instructions
From sigsock.pdf
What files are installed by SigSock, and where are they located?
You must start by installing the SigSock system to the server from this location:
http://www.topazsystems.com/Software/sigsockinstall.exe. This installs Topaz’s
standard SigPlus ActiveX SDK (version 3.89), along with a specialized SigPlus.ini file,
and SigSock.exe client, which must run on the client machine. During install, please
make sure to choose the signature pad model you will be using from the list.
When finished, you will find the SigSock.exe file in the WIN\SigPlus\Tools\SigSock
folder on the server. This SigSock.exe file must be copied over to each local client
machine that is to use the Topaz HSB signature pad.
Next, copy the WIN\SigPlus.ini file to each signature pad user’s profile Windows
directory on the server. The location of the user profile Windows folder is as follows:
Documents and Settings\%login_name%\Windows
Without this file in the appropriate location, the signature pad parameters will not be
available to the user when they log in, and SigSock (nor the signature application) will
work.
How do I use the SigSock.exe?
SigSock.exe must be run on the client machine before the signature pad can be utilized
in a server-based signature application. Copy SigSock.exe to whatever location on the
client you prefer; it does not matter, as long as you can run SigSock.exe with command
line parameters.
SigSock must be called and provided with several command line arguments in order to
function properly, named and defined as follows:
hostname
clientname
tablettype
hostname:
The FQDN (fully-qualified domain name) of the server, as in myhost.example.com
clientname:
This name can be set as you prefer. It must, however, match the TabletPortPath
parameter in the SigPlus.ini file (see “How is the SigPlus.ini file to be configured”
below). By default, the sigsockinstall.exe sets this value as:
TabletPortPath=test
So, you may pass “test” as the clientname, but ultimately you will want to change this
value in the user’s specific INI file, and be sure to pass it here as the second argument
in your call tablettype:
© 2010 ADL Data Systems, Inc. All Rights Reserved
17
ADL Optimum Series
Topaz Signature Pad Installation Instructions
Always pass a value of 6 in the argument (as 6 is used to specify the Topaz “HSB” pad)
An example call to run SigSock.exe might be something like this:
SigSock.exe myhost.example.com test 6
Be sure to call and run SigSock.exe with the proper parameters before attempting to run
and use the signature application on the server.
How is the SigPlus.ini file to be configured?
Once sigsockinstall.exe has been installed to the server, you can find the appropriate
SigPlus.ini file in the server’s WIN directory. As mentioned previously, the SigPlus.ini file
must be copied to each user’s local Windows folder, in the following location:
Documents and Settings\%login_name%\Windows
There are two parameters that you need to make sure are set in order to use
SigSock.exe
TabletType
TabletPortPath
Simply make sure that the TabletType=7. The value of 7 tells SigPlus to expect data to
come in from the SigSock.exe running on the client computer.
TabletPortPath can be set to whatever value you prefer; however, you must make sure
that whatever is set in TabletPortPath is also used as the second argument (clientname)
in the call when running the SigSock.exe (see “How do I use the SigSock.exe” section
above). The clientname parameter and the TabletPortPath values must match.
By default, SigPlus.ini is installed with the TabletPortPath=test
All other values should be set up for the particular signature pad model used in the
capture process (such as TabletModel, etc.). In general, you should not need to change
any parameter in the SigPlus.ini file except for the TabletPortPath parameter.
When testing using the demoexe the firwall blocked access, choose to allow access
© 2010 ADL Data Systems, Inc. All Rights Reserved
18
ADL Optimum Series
Topaz Signature Pad Installation Instructions
© 2010 ADL Data Systems, Inc. All Rights Reserved
19
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF