r5000 platform - TELCO SUPPORT

r5000 platform - TELCO SUPPORT
METROBILITY®
R5000 PLATFORM
100 BASE
100 BASE
redundant twister “
10 BASE
PWR
100 BASE
redundant twister “
100 BASE
PWR
PWR
100 BASE
100 BASE
PWR
100 BASE
PWR
10 BASE
PWR
100 BASE
PWR
100 BASE
PWR
1000BASE
OC-12
1000BASE
PWR
SX
PWR
MGT-10
PWR
PWR
LK
SW
MAIN
PWR
LK
SW
AT
RESET
SECONDARY
R
X
T
X
TP
LK
LK
AT
AT
T
X
PRIMARY
R
X
M
M
T
X
LK
AT
R
X
S
M
T
X
LK
AT
R
X
PWR
LK
AT
SW
AT
RESET
SECONDARY
T
X
LK
AT
R
X
S
M
T
X
RESET
MAIN
LK
FL
LK R
X
AT
T
X
R
X
M
M
LK
AT
R
X
T
X
M
A
I
N
AT
P
R
I
AT
LK
PRIMARY
LK R
X
LK
AT
AT
T
X
LK
LK
S
E
C
AT
R
X
M
M
LK
AT
T
X
R
X
M
M
T
X
TP
TX
LK
LK
LK
AT
AT
AT
AT
FL
R
X
S
M
T
X
LK
AT
R
X
S
M
T
X
TX
LK
LK
AT
R
X
T
X
FX
LK
AT
R
X
T
X
R
X
M
M
T
X
SX
LK
R
X
M
M
T
X
LK
AT
LK
2
AT
FX
LK
AT
R
X
T
X
LX
LX
LK
LK
AT
S
M
S
M
SEC
Installation & User Guide
Model: R5000-17HS
1
LK
M
M
LK
R
X
S
M
T
X
PWR
LK
C
O
N
S
O
L
E
A
B
R
ER
Metrobility Series
R5000 Platform:
R5000-17HS ______ 17-slot 2U platform
Accessories:
ACPS-17HS _______ Load-sharing hot-swappable AC power supply
DCPS-17HS _______ Load-sharing hot-swappable DC power supply
R000-01 __________
Blank panels (6)
R5000-RM ________ 23-inch rack-mounting hardware
The following is a listing of available Metrobility line cards and software. Refer to
each product’s specific installation and user guide for operational features.
Line Cards:
10Mbps
Copper to coaxial
Copper to fiber
Line Protection and
Restoration (LPR)
100Mbps
Copper to fiber
Fiber to fiber
Access
LPR
10/100Mbps
Copper to copper
Copper to fiber
Fiber to fiber
Services
Gigabit
Services
Fiber to fiber
Copper to fiber
LPR
SONET
Fiber to fiber
Multi-Rate
Fiber to fiber
T1/E1
Copper-to-fiber
T3/E3
Coaxial to fiber
Management:
R502-M __________ Management card with dual Ethernet interfaces
and embedded WebBeacon management software
NetBeacon® _______ Element and service provisioning management
software
This publication is protected by the copyright laws of the United States and other countries, with all
rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated,
transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic,
mechanical, chemical, optical or otherwise, without prior explicit written permission of Telco Systems.
© 2006 Telco Systems.
All rights reserved.
Printed in USA.
Table of Contents
Metrobility R5000 Platform Installation & User Guide
Overview .............................................................................................................. 4
Installation Guide ................................................................................................ 6
STEP 1: Unpack the Platform and Accessories .................................... 6
STEP 2: Mount the Platform in an Appropriate Location .................... 7
STEP 3: Install the Power Supply ........................................................ 8
STEP 4: Install the Line Cards ............................................................. 9
STEP 5: Connect to the Network ......................................................... 9
STEP 6: Attach the Grounding Lug (Optional) .................................. 10
STEP 7: Apply Power to the Platform ................................................ 10
STEP 8: Boot the Management Card ................................................. 12
User Guide ......................................................................................................... 13
Management Card .............................................................................. 13
Line Cards .......................................................................................... 13
Platform Technical Specifications ...................................................... 14
Operating Features of the Load-Sharing Power Supply ..................... 15
Service Instructions for the Power Supply ......................................... 16
Topology Solutions ............................................................................ 17
Product Safety, EMC and Compliance Statements ............................ 18
Warranty and Servicing ...................................................................... 19
Lancast, Metrobility, Metrobility Optical Systems, NetBeacon and “twister” are registered trademarks; the
Metrobility Optical Systems logo, WebBeacon and “redundant twister” are trademarks of Telco Systems,
a BATM company. All others are trademarks of their respective owners.
The information contained in this document is assumed to be correct and current. The manufacturer is
not responsible for errors or omissions and reserves the right to change specifications at any time
without notice.
Overview
The Metrobility R5000 Platform is an IP services demarcation unit
that operates where electrical and optical networks converge to deliver managed,
high availability solutions for distance, copper-to-fiber, and fiber-to-fiber
connectivity. Using the platform, network designers can implement and manage
high-speed fiber connections from the Central Office to the point of presence
(POP) at the client site.
Available as a 19" or 23" rack-mount platform with slots for a management card
and up to 16 line cards, the R5000 supports two load-sharing, hot-swappable AC
or DC power supplies to ensure nonstop operation. The Metrobility suite of line
cards support IP/Ethernet interfaces at 10, 100, 1000Mbps, T1/E1, T3/E3,
SONET OC-3/STM-1, OC-12/STM-4, and multi-rate, as well as Ethernet, Fast
Ethernet, and Gigabit Ethernet redundant data paths.
To increase reliability and reduce troubleshooting time, there are several
management options. The SNMP management card collects a variety of network
data and link information including the unit’s voltage and temperature.
NetBeacon® management software provides proactive management support
including automatic e-mail notification. For Web-based management of the
R5000 using a standard Web browser, there is the WebBeacon kernel embedded
into the management card.
The Metrobility carrier class solutions provide seamless connectivity with all
major switch and router manufacturers and offer a flexible solution for fiber
connectivity while reducing costs and adding functionality.
The Metrobility R5000 Platform provides the following key features:
• Support for two hot-swappable, load-sharing AC or DC power supplies.
• Optional management card for SNMP management using the NetBeacon
software or any SNMP application.
• WebBeacon, embedded in the management card, that enables the monitoring and management of network connections via the Internet using standard
browsers such as Netscape® Navigator® or Microsoft® Internet Explorer.
• Separate bus paths for management, data, and power for more efficient
internal communications.
4
Overview
• Strict standards compliance ensuring compatibility with other vendors’
equipment for flexible connectivity.
• Rugged rack-mount ears with heavy-duty handles.
• Certified for NEBS Level 3 (DC only).
Related Documentation
Refer to the following documents for additional specific information on the
Metrobility R5000 Platform:
• Metrobility 10Mbps Single Interface Line Cards Installation & User
Guide
• Metrobility 100Mbps Single Interface Line Cards Installation & User
Guide
• Metrobility 10Mbps Redundant Interface Line Cards Installation & User
Guide
• Metrobility 100Mbps Redundant Interface Line Cards Installation & User
Guide
• Metrobility 1000Mbps Redundant Interface Line Cards Installation &
User Guide
• Metrobility 10 and 100 Mbps Interface Line Cards Installation & User
Guide
• Metrobility 10/100Mbps Interface Line Cards Installation & User Guide
• Metrobility Gigabit Ethernet Services Line Card Installation & User
Guide
• Metrobility Gigabit Single Interface Line Cards Installation & User Guide
• Metrobility 1Gbps Interface Line Cards with SFP Optics Installation &
User Guide
• Metrobility SONET Single Interface Line Cards Installation & User
Guide
• Metrobility Access Line Cards Installation & User Guide
• Metrobility Multi-Rate Line Card Installation & User Guide
• Metrobility T1/E1 Single Interface Line Cards Installation & User Guide
• Metrobility T3/E3 Single Interface Line Cards Installation & User Guide
• Metrobility Chassis Stacking Line Card Installation & User Guide
• Command Line Interface Reference Guide
• NetBeacon Management Software Installation & User Guide
• WebBeacon Management Software Installation & User Guide
Metrobility R5000 Platform
5
Installation Guide
Follow the simple steps outlined in this section to install and start using the
Metrobility R5000 Platform.
1
Unpack the Platform and Accessories
Check that the following components have been included:
• Metrobility R5000 Platform
• Rack-mounting hardware
• Six (6) blank panels for unused slots
• Four (4) rubber feet
The following items are available separately:
• AC or DC power supplies
• Management cards
• NetBeacon management software
• Line cards
• 23" rack-mounting hardware
• Blank panels for unused slots
Your order has been provided with the safest possible packaging, but
shipping damage does occasionally occur. Inspect it carefully. If you
discover any shipping damage, notify the carrier and follow their
instructions for damage and claims. Save the original shipping carton if
return or storage of the unit is necessary.
6
Installation Guide
2
Mount the Platform in an Appropriate Location
Rack Mounting the Platform
The R5000 Platform is designed to be mounted flush or recessed in a
standard 19- or 23-inch equipment rack. Use the rack-mounting
hardware included with the R5000 to secure the mounting brackets to
the platform. Use separate screws provided with the equipment rack to
mount the platform in the rack. Make sure that the mounting of the
equipment in the rack does not impose a hazardous condition due to
uneven mechanical loading. Consider the overall loading of the branch
circuit before installing any equipment into a rack. Ensure that reliable
grounding is maintained in the rack system. This unit is intended to be
connected to earth ground.
Caution: Elevated ambient conditions can occur in an enclosed
equipment rack or multi-rack assembly. When installing the platform,
make sure that the exhaust fan at the back of the unit is not blocked—
improper venting of the exhaust fan can cause the unit to overheat.
Desktop Installation
When using the platform as a standalone unit on a desktop, attach the
four rubber feet to the bottom corners of the unit and place it on a flat
surface. The feet provide a space for air circulation.
The R5000 must be located within six (6) feet of the AC or DC power
source being used and placed as far away as possible from electrical
noise generating equipment such as copiers, electrostatic printers and
other motorized equipment. If exposed twisted-pair wiring is used
nearby, the wiring should be routed as far away as possible from power
cords and data cables to minimize interference.
Do not place any equipment, including another platform, on top of the
R5000 when it is placed on a desktop.
TUV Compliance Note
For pluggable equipment, the socket outlet must be installed near the equipment and be easily accessible.
Bei Geräten mit Steckanschluß muß die Steckdose nahe dem Gerät angebracht und leicht zugänglich sein.
Metrobility R5000 Platform
7
3
Install the Power Supply
Follow the steps outlined below to install the ACPS-17HS or DCPS17HS power supply into the Metrobility R5000 platform.
Do not apply power to the power supply while it is out of the platform.
IMPORTANT
Disconnect all power sources before
installing the power supply.
A blank panel must remain installed
in any empty power supply slot.
For each power supply you are installing, do the following:
• Remove the blank panel from the back of the platform.
•
Insert the power supply into the slot. Do not force it into the
platform unnecessarily. It should slide in easily and evenly.
•
Push gently until the face panel is flush with the platform.
•
Turn the thumb screws clockwise and tighten to secure the power
supply into the platform.
R5000-17HS
PWR
ACPS-17HS
PWR
DISCONNECT ALL POWER
SOURCES BEFORE SERVICING
ACPS-17HS
DISCONNECT ALL POWER
SOURCES BEFORE SERVICING
AC IN
100-120 /
200-240V
50-60Hz
2A
WARNING
AC IN
100-120 /
200-240V
50-60Hz
2A
WARNING
FACTORY DEFAULT
SETTING 115V
CAUTION
FACTORY DEFAULT
SETTING 115V
CAUTION
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
R5000-17HS
PWR
DCPS-17HS
PWR
DISCONNECT ALL POWER
SOURCES BEFORE SERVICING
Made
in
in
USA
USA
DC IN 48V, 4.9A
CAUTION
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
8
DCPS-17HS
DISCONNECT ALL POWER
SOURCES BEFORE SERVICING
Made
DC IN 48V, 4.9A
CAUTION
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Installation Guide
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
4
Install the Line Cards
The R5000 platform supports multiple media types—via line cards—in
any combination. These cards offer the ease of plug-and-play installation and are hot-swappable. Up to 17 line cards can be installed in the
platform. Refer to each card’s user guide for detailed installation
instructions.
Before installing any card, note the following:
• The management card must be installed in slot #17.
• All other cards can be installed into any slot.
• All switches and jumpers on the cards must be set prior to installation. Refer to each card’s specific user guide for a complete description of the settings.
5
Connect to the Network
Connecting the Management Card
The management card supports 10Base-T Ethernet.
• Using a standard Category 3, 4, or 5 UTP cable, connect the management card to your network. Although the port can be configured for
either full or half duplex, half duplex is recommended. Refer to the
Command Line Interface Reference Guide for a detailed description
of configuration commands.
• Using the supplied null-modem console cable, connect the male DB9 port on the management card to the serial port on your PC.
Connecting the Line Cards
To connect the individual cards to the network, refer to their corresponding installation and user guides.
Metrobility R5000 Platform
9
6
Attach the Grounding Lug (Optional)
On the back panel, the R5000 provides two vertical grounding points
where a grounding lug can be installed. Use a Panduit® copper, standard barrel, two-hole lug (part number LCD8-10A-L) or its equivalent.
Use two 10-32 screws to fasten the lug to the platform. Use a No. 8
AWG copper wire to connect the lug to the grounding point at your site
R5000-17HS
PWR
DCPS-17HS
PWR
DISCONNECT ALL POWER
SOURCES BEFORE SERVICING
Made
in
in
USA
USA
DC IN 48V, 4.9A
CAUTION
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
DCPS-17HS
DISCONNECT ALL POWER
SOURCES BEFORE SERVICING
Made
DC IN 48V, 4.9A
CAUTION
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
.
7
Apply Power to the Platform
Power connections for the ACPS-17HS and DCPS-17HS power supply
are located on the rear of the platform. When illuminated, the power
(PWR) LED on the power supply’s front panel indicates that the power
supply is turned on, connected to an active power source, and providing
power to the platform’s backplane. Because the power supplies are
load-sharing, the PWR LEDs on both power supplies illuminate
simultaneously when two supplies are installed.
DC Power Supply Connections
For DC power supply connections, follow these guidelines:
• Make sure the power switch is in the OFF position (O).
• Remove the plastic safety cover to expose the terminals.
• Connect the wire leads to the appropriate terminals. There is one
each for a positive, a negative and a platform ground. To make a
connection, loosen the terminal screw, insert the exposed wire, then
tighten the screw. If two power supplies have been installed, connect
each power supply to a separate power source.
• Replace the plastic safety cover over the terminal block.
10
Installation Guide
• Set the power switch to the ON position (I).
• Verify proper connection and operation via the PWR LED on the
power supply front panel. The LED is lit when the power supply is
functioning properly.
Note: The DCPS-17HS is designed to protect against overheating. The
power supplies will go into thermal shut-down mode if they are
operated above the specified temperature of 50°C. Normal operation
can be reestablished once the temperature drops to the specified range
by power cycling the unit.
Caution: A fully loaded platform is rated for 4.9A DC maximum
current. Make sure that the supply current available is sufficient to
power the R5000. Refer to rear panel text for voltage/current ratings.
The center terminal connector provides grounding for the platform and
must be maintained. Particular attention should be given to power
supply connections other than direct connections to the branch circuit
(e.g. use of power strips).
Important: The terminal block safety cover must be installed when
power is present to prevent burn or energy hazards.
AC Power Supply Connections
The ACPS-17HS includes a standard North American 3-pin power
cord which is UL (USA), CSA or CUL (Canada) listed or approved.
For installation in regions outside North America, replace the power
cord with a cord approved by appropriate safety agencies. The cord
must have a CEE-22 standard V female connector on one end and
meet IEC 320-030 specifications. European power cords must be
harmonized and designated with a HAR marking on the outside of the
cord jacket to comply with the CENELEC Harmonized Document
HD-21.
Warning
The default voltage setting on the ACPS-17HS is 115V AC. Before
applying power, make sure the voltage switch is set appropriately
for the voltage source in your region.
Metrobility R5000 Platform
11
For AC power supply connections, follow these guidelines:
• Make sure the power switch is in the OFF position (O).
• Plug the AC cord into the connector on the power supply, then insert
the other end of the cord into the AC power source. If two power
supplies have been installed, connect each power supply to a
separate power source.
• Set the power switch to the ON position (I).
• Verify proper connection and operation via the PWR LED on the
power supply front panel. The LED is lit when the power supply is
functioning correctly.
Caution: A fully loaded platform is rated for 2A AC maximum current.
Make sure that the power supply current is sufficient to power the
R5000. Refer to the front panel text for voltage/current ratings.
Reliable grounding of rack-mount equipment must be maintained.
Particular attention should be given to power supply connections
other than direct connections to the branch circuit (e.g. use of power
strips).
8
Boot the Management Card
Management of the R5000 Platform can be provided through
Metrobility’s NetBeacon or WebBeacon software or any SNMP
network management application via a PC. WebBeacon is automatically installed when the management card is installed. SNMP is
supported on many general network platforms: SunNet Manager, HP
OpenView for UNIX, HP OpenView for NT, SNMPc and others.
Refer to the Command Line Interface Reference Guide for a detailed
description of how to boot for SNMP management and a complete
listing of configuration commands.
12
Installation Guide
User Guide
This section contains information regarding certain operating features and
maintenance instructions for the Metrobility R5000 Platform.
Management Card
The management card is the SNMP agent for the Metrobility R5000. Connected
via the backplane to the cards in the platform, the management card reports
individual board status to Metrobility’s NetBeacon software or any SNMP
application. Thus, the network administrator receives immediate information on
network operations via a PC. The WebBeacon kernel is embedded into the
management card for Web-based management via the Internet using browsers
such as Netscape Navigator or Microsoft Internet Explorer. Refer to the
Command Line Interface Reference Guide, NetBeacon Element Management
Software Installation & User’s Guide, or WebBeacon Management Software
Installation & User’s Guide for detailed software commands.
Line Cards
The Metrobility family of line cards deliver carrier-class media, speed, and
distance solutions to address the needs of today’s telecommunications networks.
An extensive line of plug-and-play, hot-swappable cards support IP/Ethernet
interfaces at 10, 100, 1000Mbps, T1/E1, T3/E3, SONET OC-3/STM-1 and OC12/STM-4. For mission-critical applications, Ethernet, Fast Ethernet, and
Gigabit Ethernet redundant line cards feature network-on-demand accessibility,
reliability and enhanced security.
Up to 17 line cards fit into a Metrobility R5000 Platform. Maximum segment
lengths are supported on either side of the devices, and all signal activity is
reliably propagated from one cable to the other assuring accurate data flow
across the network.
Automatic half-duplex or full-duplex operation ensures compatibility with
devices from other leading network technology providers.
Refer to the each line card’s specific installation and user guide for additional
information.
Metrobility R5000 Platform
13
Platform Technical Specifications
Power
ACPS-17HS
Input Operating Range _______________ 100-120/200-240V AC, 50-60Hz, 2A
DCPS-17HS*
Input Operating Range _________________________________ 48V DC, 4.9A
Environmental
Operating Temperature ____________________________________ 0° to 50° C
Storage Temperature ____________________________________ -30° to 70° C
Relative Humidity __________________________ 5% to 95% non-condensing
Physical Case _________________________ Fully enclosed metal construction
Dimensions __________________________________ 15.0"L x 17.0"W x 3.5"H
(38.1cm L x 43.18cm W x 8.89cm H)
Weight _________________________________________ 11 lb, 5 kg (platform)
_____________________________ 3.25 lb, 1.47 kg (AC power supply)
_______________________________ 3 lb, 1.36 kg (DC power supply)
* The DC power supply is approved up to 60V DC.
14
User Guide
Operating Features of the Load-Sharing Power Supply
The ACPS-17HS and DCPS-17HS load-sharing power supplies are designed for
AC and DC power sources, respectively. Both power supplies are fieldreplaceable. Refer to Step 3 in the Installation Guide section of this manual for
instructions on how to install the power supply. Refer to the next section,
Service Instructions for the Power Supply, for a complete description of how to
replace the power supply.
When a platform is equipped with two load-sharing power supplies, they
operate in tandem and share the load. If the power source to one of the supplies
fails or is removed, the other power supply automatically provides the entire
power load to the platform. This setup provides both the platform and the
network with uninterrupted service. It also decreases the demand placed upon an
individual power supply, thus prolonging its life.
When the power (PWR) LED on the front panel of the power supply is lit, it
indicates that the power supply is turned on, connected to an active power
source, and providing power to the platform backplane. Because the ACPS17HS and DCPS-17HS are load-sharing, when two power supplies are installed
and active in a single platform, the LEDs on both supplies are lit simultaneously.
An optional management card provides visible verification of operating status
from the front of the platform. The R502-M, which must be installed in slot #17,
has two LEDs labeled A and B. When lit, these LEDs indicate that their
corresponding power supplies are installed properly, connected to an active
power source, turned on, and providing power to the platform backplane. When
two power supplies are installed and active in a single R5000 platform, both
LEDs are lit simultaneously.
PWR
DCPS-17HS
PWR
DISCONNECT ALL POWER
SOURCES BEFORE SERVICING
MGT-10
ACPS-17HS
DISCONNECT ALL POWER
SOURCES BEFORE SERVICING
LK
1
AT
LK
Made
AC IN
100-120V/
200-240V
50/60Hz
2A
in
2
USA
AT
PWR
DC IN 36-72V, 6A
WARNING
CAUTION
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
FACTORY DEFAULT
SETTING 115V
CAUTION
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
DCPS-17HS
Rear Loading Power Supply
RISK OF ELECTRIC
SHOCK, DO NOT OPEN
C
O
N
S
O
L
E
A
B
LEDs
for
Power
Supplies
A and B
R
ER
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
ACPS-17HS
Rear Loading Power Supply
R502-M
Management
Card
Metrobility R5000 Platform
15
Service Instructions for the Power Supply
The following instructions explain how to replace an ACPS-17HS or
DCPS-17HS power supply in the Metrobility R5000 Platform.
IMPORTANT
Disconnect all power sources before removing
or installing a power supply module.
A blank panel must remain installed
in any empty power supply slot.
16
•
Remove all power cords or wire leads from the power supply. Do
not apply power to the power supply while it is out of the platform.
•
Remove the power supply from the platform.
•
Insert the replacement power supply into the slot. Do not force it
into the platform unnecessarily. It should slide in easily and
evenly.
•
Push gently until the face panel is flush with the platform.
•
Turn the thumb screws clockwise and tighten to secure the
power supply into the platform.
•
ACPS-17HS: Attach the power cord to the AC receptacle.
•
DCPS-17HS: Remove the terminal block safety cover. Attach
the wire leads to the appropriate terminal block connections;
there is one each for a positive, a negative, and a platform
ground. Replace the plastic safety cover.
•
Reconnect to the appropriate active power source.
•
Verify proper connection and operation via the power (PWR)
LED.
User Guide
Topology Solutions
Radiance R5000 Platform
CENTRAL OFFICE
POP
Radiance R5000 Platform
CPE
CPE
CPE
20 km
CPE
POP
Radiance R5000 Platform
40 km
CPE
CPE
100 km
1000Mbps
100Mbps
10Mbps
CPE
Metrobility SONET/Gigabit Standalone
Metrobility R5000 Platform
17
Product Safety, EMC and Compliance Statements
This equipment complies with the following requirements:
• UL
• CSA
• EN60950 (TUV)
• FCC Part 15, Class A
• EN55022 Class A (emissions)
• EN50082-1 (immunity)
• IEC 825-1 Classification
• Class 1 Laser Product
• ICES-003 Class A (emissions)
• NEBS Level 3 Certification (DC only)
• CB
This product shall be handled, stored and disposed of in accordance with all
governing and applicable safety and environmental regulatory agency requirements.
The following FCC and Industry Canada compliance information is applicable
to North American customers only.
USA FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses
and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Caution: Changes or modifications to this equipment not expressly approved by
the party responsible for compliance could void the user’s authority to operate
the equipment.
Canadian Radio Frequency Interference Statement
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du
Réglement sur le matériel brouilleur du Canada.
18
User Guide
Warranty and Servicing
Telco Systems’ Product Warranty
TELCO MAKES NO WARRANTIES EXCEPT AS HEREIN SET FORTH: Telco warrants that the equipment and accessories
manufactured by Telco, when used in the application and manner for which they are intended, will be free from defects caused by
faulty material or poor workmanship from the date of shipment. This warranty is subject to change at any time. The warranty that
applies is that which is in effect at the time the equipment ships. Warranty period is specific to particular product offerings. These
periods are as follows:
Metrobility Products- 1 year
IP and EdgeGate Products – 1 year
Telco’s liability under this warranty is limited to, the obligation, at Telco’s sole option, to repair or, to replace at Telco’s plant at
Massachusetts, any part found to be defective under normal use and service within the warranty period specified herein, provided:
a) Telco is promptly notified in writing upon discovery of such defects;
b) The defective parts are returned to Telco, transportation charges prepaid in accordance with Telco’s instructions;
c) Telco’s examination shall disclose to its satisfaction that such defects have not been caused by misuse, abuse,
neglect, accident, or adjustments other than those specified in the Telco Operating and Maintenance Manual. Telco shall
have no responsibility under this warranty for defects, which have been caused by misuse, abuse, improper application,
repair, alteration, accident or negligence in use, storage, transportation or handling. Further, the original identification
markings must not have been removed, defaced or altered.
d) Equipment has been installed and operated, and maintained, in complete accordance with the Telco Operating and
Maintenance Manual, and good engineering practice.
Though component parts of Telco-manufactured goods are covered by the above warranty, TELCO MAKES NO WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE NOR ANY OTHER WARRANTY, EXPRESS OR
IMPLIED, FOR ANY EQUIPMENT OR MERCHANDISE NOT MANUFACTURED BY TELCO (FOR EXAMPLE BUT
WITHOUT LIMITATION, ACCESSORIES AND AUXILIARY ITEMS).
However, Telco will cooperate reasonably with Purchaser in attempting to secure, where possible, the benefit of any warranties which
the manufacturer of such non-Telco items may provide. All ordered replacement parts or parts replaced during the warranty period
assume the unexpired portion of the original parts warranty or ninety (90) days from date of shipment, whichever is longer.
Replacement, Repair or Refund Procedure for Hardware: Telco’s sole obligation under this express warranty shall be, at Telco’s
option and expense, to repair the defective product or part or deliver to Customer an equivalent product or part to replace the defective
item. All products that are replaced will become the property of Telco Systems. Replacement products or parts may be new or
reconditioned. Telco warrants any replaced or repaired product or part for ninety (90) days from shipment, or the remainder of the
initial warranty period, whichever is longer. Telco reserves the right to refund the purchase price paid for the defective product as its
exclusive warranty remedy.
To Receive a Return Materials Authorization (RMA) Number: Please contact the party from whom you purchased the product. If
you purchased the product directly from Telco Systems, contact the Telco Systems Customer Care Group.
Software: Telco warrants to Customer that each software program licensed from it will, if operated as directed in the user
documentation, substantially achieve the functionality described in the user documentation for a period of ninety (90) days from the
date of purchase from Telco or its authorized reseller. No updates or upgrades are provided under this warranty. Telco’s sole obligation
under this express warranty shall be, at Telco’s option and expense, to refund the purchase price for the software product or replace the
software product with software which meets the requirements of this warranty as described above. Customer assumes responsibility
for the selection of the appropriate programs and associated reference materials. Telco expressly disclaims any warranty or
representation that its software products will meet Customer’s requirements or work in combination with any hardware or software
products provided by third parties, that the operation of the software products will be uninterrupted or error free, or that all defects in
the software products will be corrected.
The foregoing warranties are in lieu of any and all other warranties, expressed or implied, including, but not limited to, warranties of
merchantability, fitness for a particular purpose or against infringement of any rights of third parties. Telco’s liability on any claim for
money damages (including, without limitation negligence for any loss or damage arising out of, connected with, or resulting from the
sale of products hereunder, or from the performance or breach thereof, or from the design, manufacture, sale, delivery, resale,
installation, inspection, repair, operation or use of any merchandise manufactured by Telco) shall in no case exceed the price allocable
to the merchandise or part thereof which gave rise to the claim. Purchaser will hold Telco harmless with respect to any claims or
actions by third parties. In particular, Telco expressly disclaims and shall in no event be liable for any indirect, special, incidental or
consequential damages.
Metrobility R5000 Platform
19
US Headquarters
2 Hampshire St., Ste. 3A Foxboro MA 02035 USA
tel: 1.781.551.0300 • fax: 1.781.255.2344
www.telco.com
5660-000016 H
12/06