P R O TA K A L
DataLoggingSoftware
- Suitable for data logging from all types of devices which uses MODBUS RTU/ASCII protocols.
- Channels can be defined from Unlimited Serial ports
- Software starts automatically after Computer turns on. Only one time configuration.
- Enables graphic visualisation for very fast processes.
Possible to log data for every 50ms.
- Every channel has its own graphical screen.
Channels can be displayed in the same graphical screen when necessary.
- Channels are grouped in the main screen according to their group names.
- Data logging in Excel, XML, HTML and unlimited ASCII formats
- Creates files in configurable time intervals during data logging.
- Graphics saved in JPEG, PNG, GIF, PCX, VML, PostScript and PDF formats.
- Enables graphic visualisation in a ms resolution,
2-Dimension or 3-Dimension,colourful or black-white.
- Channel configurations are all independent.
Channel configurations can be stored in a file and can be read.
- Supports "Write Single Register" Modbus command. User may change device control parameters with this feature.
- Supported value types: Signed Integer, Unsigned Register, Signed Long, Unsigned Long and Float (IEEE 754).
Step1) Add New Device
New device can added by Add New Channel button
1
www.emkoelektronik.com.tr
P R PROTAKAL
O TA K A L
Step2) Channel & Device Settings
Channel Name : User should enter a name for a new additional device
Group Name
: User should enter a name for a new group. If user would like to add
a new device into the the Same Group, user should use same Group Name.
Read Interval
: Logging intervals time can be determine by user (1 to 9999 second)
Response Time: Every controllers have got different response times.
User could find this information from the device’s producer. If user doesn’t
know the Response Time, at least 999 msec should be entered
Please enter 650msec for EMKO devices
Timeout
: If devices can not communicate during this time,
software will indicate timeout error. Adviced timeout value is 1000msec
Step3) Modbus Settings
ComPort : After power on, if it is the first time to run the program PC comport
setting should be made.
Start>All Programs>Administrative Tools>Computer Management>Device Manager
Please click Ports Button
to learn new Comport Number
BaudRate : Communication Baud Rate
ByteSize : Byte Selection for Communication
Parity
: Parity Selection for Communication
StopBits : Stop Bit Selection for Communication
* Software and devices’ Communication Parameters must be same
Default Values of Communication Paramters for EMKO products ;
BaudRate : 9600
Parity
ByteSize : 8
StopBits : 1
Slave ID
: No ( parity )
: User should enter Device’s ID number into this blank.
(It can be be adjutment from 1 to 247 according to Device’s ID number)
Function : User should choose required Registers type ;
Read Holding Registers (4XXXX) code is used to write new value into the device
Read Input Register (3XXXX) code is used to read data from the device.
Offset
: This offset value is extension/complete part for registers code.
User should enter required value into the this part for logging to process value,
set value, alarm Value
Example for ESM-XX50 series ;
To read Process Value
- Register Function should be selected Read Input Register (3XXXX)
- Offset Value should be “ 0 ”
* You can see samle Offset Values on the Page Down for EMKO devices
2
w w w. e m k o e l e k t r o n i k . c o m . t r
P R O TA K A L
I/O Type
: Communication data type can be different for every device.
Please contact device’s producer to get correct data type
I/O type for EMKO devices’
ESM-XX50 series
: Signed Integer S16
ESM-XX00 series
: Signed Integer S16
EZM-XX50 Controller : Unsigned Integer U16
Gen-Set Controller
: Signed Integer S16
Step4) Sample Offset Values
For ESM-XX50 series
Process Value
:0
Process Set Value : 0
Alarm-1 Value
:1
Alarm-2 Value
:2
Alarm-3 Value
:3
[Register Function should be selected as Read Input Register (3XXXX)]
[Register Function should be selected as Read Holding Registers (4XXXX)]
[Register Function should be selected as Read Holding Registers (4XXXX)]
[Register Function should be selected as Read Holding Registers (4XXXX)]
[Register Function should be selected as Read Holding Registers (4XXXX)]
For ESM-XX00 series
Alarm-1 Value
Alarm-2 Value
Alarm-3 Value
: 0 [Register Function should be selected as Read Holding Registers (4XXXX)]
: 1 [Register Function should be selected as Read Holding Registers (4XXXX)]
: 2 [Register Function should be selected as Read Holding Registers (4XXXX)]
For EZM-XX00 series
Process Value
Output-1 Action
Output-2 Action
: 2 [Register Function should be selected as Read Input Register (3XXXX)]
: 13 [Register Function should be selected as Read Holding Registers (4XXXX)]
: 14 [Register Function should be selected as Read Holding Registers (4XXXX)]
For EAOM-210FL ;
Load Current IL1 : 16 [Register Function should be selected as Read Input Register (3XXXX)]
Load Current IL1 : 17 [Register Function should be selected as Read Input Register (3XXXX)]
Load Current IL1 : 18 [Register Function should be selected as Read Input Register (3XXXX)]
Mains Voltage L1N : 20 [Register Function should be selected as Read Input Register (3XXXX)]
Mains Voltage L2N : 21 [Register Function should be selected as Read Input Register (3XXXX)]
Mains Voltage L3N : 22 [Register Function should be selected as Read Input Register (3XXXX)]
* Please contact us to get all of the Register code
3
w w w. e m k o e l e k t r o n i k . c o m . t r
P R PROTAKAL
O TA K A L
Step5) Channel Color Settings
Channel Color
: User may change the Channel Graphics Color by this button
Background Color : User may change the Graphics Background Color by this button
Grid Color
: User may change the Grid Color by this button
Axis Color
: User may change the Axis Color by this button
To Indicata All Channel Graphics in the Same Screen
Please press to STOP button
and select the Channel Name
which you want to see from the Channel Name menu.
And press to START button
to continue datalogging,
Selected channel graphics will apper the same screen
4
w w w. e m k o e l e k t r o n i k . c o m . t r
P R PROTAKAL
O TA K A L
Step6) Logging Settings
Pic-1
Value Format
: User can select decimal point position of value by this button.
Important Point ! Point position should be as same as device point position.
New File Interval
: User can determine how often a new file will be created
New Folder Interval : User can determine how often a new folder will be created
Title
: User can enter a graphics name.
For Creating New Folder ;
Please click to right button of the mouse in the Logging Directory window and push to Create New Folder by left button of the
Mouse. ( Please look at the following picture / Pic-1 )
To open saved setting from file
To save new setting to file
To START the logging
To STOP the logging
Step7) Graphics Tools
Channel Settings
Write Single Register
Three Dimension
Load Zoom
Save Zoom
Zoom Fit Best
Zoom Last Value
5
w w w. e m k o e l e k t r o n i k . c o m . t r
P R O TA K A L
Channel Settings Button :
This button is used to change channel setting at continued process.
* Please press to STOP button before the changing
* After the changing, please press to START button
Write Single Register Button :
This button is used to change device’s parameters as ; Process SET Values,
Alarm SET Values...etc Also, user can reach Write Single Register button
from the PROTAKAL manu.
* Please enter following Register-Offset code into the Offset blank (Pic-2)
* Please enter necessary Process SET values or Alarm SET values into
Pic-2
The Value blank (Pic-3)
ESM-XX00 series ;
Alarm-1 SET Value : 0
Alarm-2 SET Value : 1
Alarm-3 SET Value : 2
ESM-XX50 series ;
Process SET Value : 0
Alarm-1 SET Value : 1
Alarm-2 SET Value : 2
Alarm-3 SET Value : 3
* Please contact us to get all of the Register code
Pic-3
Step8) Channel List
Channel List : User can follow all of the Channel detail
6
w w w. e m k o e l e k t r o n i k . c o m . t r
P R O TA K A L
Step9) Open Log File
Open Log File : User may open a file which includes
past log file
Manage Chart
User can change to background Color, Grid Color, Axis
Color of grahics by this button for Graphics view
Import File
Export File
( Please look at the Pic-4 / Pic-5 for export data type )
Pic-5
Pic-4
Step10) Setting
Channel Settings Button :
Start at logon: When the PC open, PROTAKAL start to
datalogging automatically
Show the splash screen: To show the splash screen,
when the open the PROTAKAL
Start Icon on System Tray : To show Program icon
on the System Tray
Ask to save settings on exit : Default and adviced is
unselected type for this icon. After this icon selected,
PROTAKAL ask to load all data on startup ever time.
When the program close, If user enter NO, all data are
removed from program. If user select YES, all data are
saved on the program.
Yes
No
Cancel
7
w w w. e m k o e l e k t r o n i k . c o m . t r
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising