Below you will find brief information for Gate Operators ECOSOL LIBRA UL-R. The ECOSOL LIBRA UL-R is a gate operator that can be used for single or dual gate applications. It features a variety of programming options and a built-in radio receiver. The ECOSOL LIBRA UL-R also includes a built-in safety feature that prevents the gate from closing if there is an obstruction. The ECOSOL LIBRA UL-R is easy to install and configure.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
◉
Touch to zoom
ECOSOL/LIBRA UL-R QUICK REFERENCE Solar panel should always face south SOLAR PANEL INSTALLATION Connect the wires to the terminals labeled “Solar Panel”. Cable should not exceed 15 ft (16AWG minimum). POLARITY MUST BE RESPECTED. Check before connecting ALL BATTERIES MUST HAVE THE SAME RATING AND MUST HAVE EQUAL VOLTAGE +/- 0.7 VOLTS BEFORE INSTALLING TO ECOSOL ɑ S * BATTERY CONNECTIONS The angle of the panel (ɑ) should equal the locations latitude ≤ 10° i.e.: Dallas, TX = 33°-43°; Houston, TX = 30°-40°; Phoenix AZ = 33.5°-43.5°; San Juan, PR = 18°-28° BFT PHOBOS BT AND IGEA BT GATE OPERATORS ONLY Batteries + * Dip-switch #1 must be turned on when secondary batteries are connected MOTOR CONNECTIONS Primary Secondary Batteries + - optional PHOTOBEAM SENSOR CONNECTION Photo-beam sensors should only be used as safety devices, not as free exit Remove installed jumper. devices. Sensors must be powered from OPERATING 24VDC output Connect the normally closed contacts to terminals SAFETY and COMMON. For single gate operation, connect motor leads to MOTOR 2 terminals. Second motor must be connected to MOTOR 1 NOTE: If more than one device needs to be wired to the Safety input, they must be wired in series On a dual gate application, MOTOR 2 will start to open before MOTOR 1. In turn, MOTOR 1 will start to close before MOTOR 2 LOOP DETECTOR CONNECTIONS For free exit application, connect the normally open contacts to terminals COMMON and OPEN For obstruction detection, remove jumper and connect normally closed contacts to terminals SAFETY and COMMON Detectors must be powered from ALWAYS-ON 24VDC output NOTE: If more than one device needs to be wired to the Safety input, they must be wired in series REMOTE CONTROL PROGRAMMING 1 1. Press RADIO LEARN BUTTON once. LED3 should blink once every second. 2. Press and hold the 2 top buttons on your transmitter until LED3 lights up solid. Press the desired button on the transmitter . LED3 should blink rapidly for a second a goes back to a blink per second. If additional transmitter are to be programmed, repeat steps 2 and 3 while LED3 is blinking. System times out after 10 seconds 3. LED 3 2 3 LED LEGEND LED2 – Libra programming jumper (JP14)on LED3 – (1 flash/sec) Programming receiver channel 1 (2 flashes/sec) Programming receiver channel 2 Programming dip-switches (Steady) Hidden button programmed (3 flashes) Low battery LED 2 LED4 – Charging batteries ECOSOL PROGRAMMING JP 14 Removable Jumper Dip-switch Settings ●Switch 1 – Turn on for secondary batteries connection LED 4 ●Switch 2 – Enables Quick Radio Programming ●Switch 3 – Command relay delay (MUST BE TURNED ON) ●Switch 4 – Command relay delay LED 3 LIBRA UL-R PROGRAMMING MENU NAVIGATION Jumper must be installed over both pins on JP14 on the ECOSOL interface UP: board during Libra UL-R programming. Jumper MUST BE REMOVED after DOWN: programming. ENTER: OK Press th OK button twice to enter programming. BACK: Use the UP (+) and DOWN (-) buttons to navigate the menu. Use the ENTER (OK) button to enter a programming menu area. Use the UP & DOWN button simultaneously to navigate back within the menu and/or exit programming. am Programming Menu FlowparChart SYSTEM PROGRAMMING param tca logic m1 t tcat m2 radio 3 s tepw m1 t slo NOT USED WITH ECOSOL iblradio open m2language tradio slow fastradio cls open dela y time language photolanguage c . o pen language Menu language selection cls delay time default test photo m1 fast time default 1default mot on default m2 fast time autoset Restores settings bloc persfactory ist slow speed autoset startautoset close autoset zone fixed codtorque e Automatic setting radio prog master logic tca Auto close time m1 t Motor 1 torque tca m2 t Motor 2 torque 3 step m1 t slow m2 t slow Auto close enable Instant reverse NOT USED WITH ECOSOL ibl open START ignored on opening NOT USED WITH ECOSOL fast cls Anti-tailgate Safety input ignored on opening open delay time MOTOR 2 open delay time photoc. open cls delay time MOTOR 1 close delay time test photo m1 fast time NOT USED WITH ECOSOL 1 mot on NOT USED WITH ECOSOL bloc persist NOT USED WITH ECOSOL start close START input as CLOSE only fixed code NOT USED WITH ECOSOL radio prog NOT USED WITH ECOSOL m2 fast time slow speed zone ZONE (Advanced programming) master Technical Support: 877-995-8155 NOT USED WITH ECOSOL Single motor operation Pre-open push Master / Slave designation
advertisement
Key Features
- Single or dual gate operation
- Built-in radio receiver
- Programming options
- Built-in safety feature
- Easy to install and configure
Frequently Answers and Questions
How many gate operators are there in this document?
This document describes an operator for a single gate or dual gate.
What kind of connection can be used with this gate operator?
The ECOSOL and LIBRA UL-R operator can be connected to photo-beam sensors and loop detectors.
What is the purpose of the safety input on the ECOSOL LIBRA UL-R?
The safety input on the ECOSOL LIBRA UL-R is used to prevent the gate from closing if there is an obstruction, for example, someone walking through the gate.