BFT ECOSOL LIBRA UL-R Gate Operators Quick Reference

BFT ECOSOL LIBRA UL-R Gate Operators Quick Reference

Below you will find brief information for Gate Operators ECOSOL LIBRA UL-R. The ECOSOL LIBRA UL-R is a gate operator that can be used for single or dual gate applications. It features a variety of programming options and a built-in radio receiver. The ECOSOL LIBRA UL-R also includes a built-in safety feature that prevents the gate from closing if there is an obstruction. The ECOSOL LIBRA UL-R is easy to install and configure.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Gate Operators ECOSOL LIBRA UL-R Quick Reference | Manualzz
ECOSOL/LIBRA UL-R
QUICK REFERENCE
Solar panel should
always face south
SOLAR PANEL INSTALLATION
Connect the wires to the terminals
labeled “Solar Panel”. Cable should
not exceed 15 ft (16AWG minimum).
POLARITY MUST BE RESPECTED.
Check before connecting
ALL BATTERIES MUST HAVE THE
SAME RATING AND MUST HAVE
EQUAL VOLTAGE +/- 0.7 VOLTS
BEFORE INSTALLING TO ECOSOL
ɑ
S
*
BATTERY CONNECTIONS
The angle of the panel (ɑ) should equal the locations
latitude ≤ 10°
i.e.: Dallas, TX = 33°-43°; Houston, TX = 30°-40°;
Phoenix AZ = 33.5°-43.5°; San Juan, PR = 18°-28°
BFT PHOBOS BT AND
IGEA BT GATE
OPERATORS ONLY
Batteries
+
*
Dip-switch #1 must be turned
on when secondary batteries
are connected
MOTOR CONNECTIONS
Primary
Secondary
Batteries
+
-
optional
PHOTOBEAM SENSOR CONNECTION
Photo-beam sensors should only be used as safety devices, not as free exit
Remove installed jumper.
devices.
Sensors must be powered from
OPERATING 24VDC output
Connect the normally closed contacts to
terminals SAFETY and COMMON.
For single gate operation, connect motor leads
to MOTOR 2 terminals.
Second motor must be connected to MOTOR 1
NOTE: If more
than one device
needs to be wired
to the Safety
input, they must
be wired in series
On a dual gate application,
MOTOR 2 will start to open before
MOTOR 1. In turn, MOTOR 1 will
start to close before MOTOR 2
LOOP DETECTOR CONNECTIONS
For free exit application, connect the
normally open contacts to terminals
COMMON and OPEN
For obstruction detection, remove
jumper and connect normally closed
contacts to terminals SAFETY and
COMMON
Detectors must be powered from
ALWAYS-ON 24VDC output
NOTE: If more
than one device
needs to be wired
to the Safety
input, they must
be wired in series
REMOTE CONTROL PROGRAMMING
1
1. Press RADIO LEARN BUTTON once.
LED3 should blink once every second.
2.
Press and hold the 2 top buttons
on your transmitter until LED3
lights up solid.
Press the desired button on the
transmitter . LED3 should blink rapidly
for a second a goes back to a blink per
second. If additional transmitter are to
be programmed, repeat steps 2 and 3
while LED3 is blinking. System times out
after 10 seconds
3.
LED 3
2
3
LED LEGEND
LED2 – Libra programming jumper (JP14)on
LED3 – (1 flash/sec) Programming receiver channel 1
(2 flashes/sec) Programming receiver channel 2
Programming dip-switches
(Steady) Hidden button programmed
(3 flashes) Low battery
LED 2
LED4 – Charging batteries
ECOSOL PROGRAMMING
JP 14 Removable Jumper
Dip-switch Settings
●Switch 1 – Turn on for secondary batteries connection
LED 4
●Switch 2 – Enables Quick Radio Programming
●Switch 3 – Command relay delay (MUST BE TURNED ON)
●Switch 4 – Command relay delay
LED 3
LIBRA UL-R PROGRAMMING
MENU NAVIGATION
Jumper must be installed over both pins on JP14 on the ECOSOL interface
UP:
board during Libra UL-R programming. Jumper MUST BE REMOVED after
DOWN:
programming.
ENTER:
OK
Press th OK button twice to enter programming.
BACK:
Use the UP (+) and DOWN (-) buttons to navigate the menu.
Use the ENTER (OK) button to enter a programming menu area. Use the
UP & DOWN button simultaneously to navigate back within the menu
and/or exit programming.
am
Programming Menu FlowparChart
SYSTEM PROGRAMMING
param
tca
logic
m1 t
tcat
m2
radio
3
s
tepw
m1 t slo
NOT USED WITH ECOSOL
iblradio
open
m2language
tradio
slow
fastradio
cls
open dela
y
time
language
photolanguage
c
.
o
pen
language
Menu
language
selection
cls delay
time
default
test photo
m1 fast time
default
1default
mot on
default
m2 fast
time
autoset
Restores
settings
bloc persfactory
ist
slow speed
autoset
startautoset
close
autoset
zone
fixed codtorque
e
Automatic
setting
radio prog
master
logic
tca
Auto close time
m1 t
Motor 1 torque
tca
m2 t
Motor 2 torque
3 step
m1 t slow
m2 t slow
Auto close enable
Instant reverse
NOT USED WITH ECOSOL
ibl open
START ignored on opening
NOT USED WITH ECOSOL
fast cls
Anti-tailgate
Safety input ignored on opening
open delay time
MOTOR 2 open delay time
photoc. open
cls delay time
MOTOR 1 close delay time
test photo
m1 fast time
NOT USED WITH ECOSOL
1 mot on
NOT USED WITH ECOSOL
bloc persist
NOT USED WITH ECOSOL
start close
START input as CLOSE only
fixed code
NOT USED WITH ECOSOL
radio prog
NOT USED WITH ECOSOL
m2 fast time
slow speed
zone
ZONE (Advanced programming)
master
Technical Support: 877-995-8155
NOT USED WITH ECOSOL
Single motor operation
Pre-open push
Master / Slave designation

advertisement

Key Features

  • Single or dual gate operation
  • Built-in radio receiver
  • Programming options
  • Built-in safety feature
  • Easy to install and configure

Frequently Answers and Questions

How many gate operators are there in this document?
This document describes an operator for a single gate or dual gate.
What kind of connection can be used with this gate operator?
The ECOSOL and LIBRA UL-R operator can be connected to photo-beam sensors and loop detectors.
What is the purpose of the safety input on the ECOSOL LIBRA UL-R?
The safety input on the ECOSOL LIBRA UL-R is used to prevent the gate from closing if there is an obstruction, for example, someone walking through the gate.