Low-Profile DSX-1 Panels
Low-Profile DSX-1 Panels
Copper :: 56, 64 or 84 Terminations, Wire-Wrap or Connectorized I/O
Primary Benefits
Overview
Telect low-profile DSX-1 panels deliver the cross-connect
capabilities you need in a compact footprint to save space. All
configurations are just 4 inches in height to maximize space and
provide industry-leading density.
• 4-inch height provides 43% increase in DS1 circuit density
over 7-inch-high products
• Industry-standard design enables the use of all legacy
Bantam patch cords, including Telect Blue Nickel brand
• EIA and WECO rack mounting
• 19- to 23-inch mounting adapter brackets included with all
19-inch panels so only one part number is required within
your ordering system
• Circuit multiples match industry-standard SONET OC3, 12,
48 and 192 systems
• Gain a lifetime of reliable connections with Telect’s patented
Dedicated Digital Jacks
• Backed by T elect’s DSX lifetime warranty
Advanced cable management, patented jacks for durability, and
competitive pricing all add up to uncompromised performance in a
cost-effective package. Panels are available in wire-wrap or 64-pin
connectorized I/O configurations.
Applications
• High-density central office connectivity — bay lineups
• Low circuit count remote applications — individual panels
• Wireless or traditional wireline networks
010-0184-1010 Front View
010-0156-0010 Front View
© Telect, Inc., All Rights Reserved, 11.10.11/rev.5
1.509.926.6000 :: telect.com
1
Low-Profile DSX-1 Panels
Copper :: 56, 64 or 84 Terminations, Wire-Wrap or Connectorized I/O
DSX Jack Specifications
Overview
Description
Part Number
Test Method
56-Termination Panels
Dedicated Digital Jack
Front cross-connect, wire-wrap, 19”
010-0156-0000
Front cross-connect, connectorized, 19”
010-0156-0010
Rear cross-connect, wire-wrap, 19”
010-2156-0103
Electrical
64-Termination Panels
Front cross-connect, wire-wrap, 23”
010-0164-1000
Front cross-connect, connectorized, 23”
010-0164-1010
Rear cross-connect, wire-wrap, 19”
010-2164-0000
Rear cross-connect, connectorized, 19”
010-2164-0010
84-Termination Panels
Front cross-connect, wire-wrap, 23”
010-0184-1000
Front cross-connect, connectorized, 23”
010-0184-1010
Rear cross-connect, wire-wrap, 19”
010-2184-0001
Rear cross-connect, connectorized, 19”
010-2184-0010
Unless otherwise specified, all
appropriate products are tested
underMlL-J-641, method 202F
Insertion loss
< -0.5 dB (at 1.576 MHz)
Crosstalk
< -60 dB
Return loss
< -26 dB at 772 kHz
Monitor level
21 dB +/-1.5 dB below signal level
Contact resistance
< 0.01 ohms
Characteristic impedance
100 ohms
Mechanical
84-term. panels feature 1-84 designation and include 1-28 ABC kit.
Insertion force
4.17 lb (1.9 kg) average
Withdrawal force
5.21 lb (2.4 kg) average
Life
Minimum 20,000 insertion/withdrawal
cycles
Vibration
Per MlL–STD-202F, method 201A
Environmental
Panel Dimensions
19” panels
9” W x 4” H x 12” D
(483 mm x 102 mm x 254 mm)
23” panels
23” W x 4” H x 12” D
(584 mm x 102 mm x 254 mm)
19” panels can also be mounted in 23” racks.
Salt spray
Per MlL-STD-202F, method 101D
Moisture resistance
Per MlL-STD-202F, method 106E
Thermal limits
-40 to 149°F (-40 to 65° C) operating
-67 to 185°F (-55 to 85° C) nonoperating
Thermal shock
Per MIL-STD-202, method 107D
Humidity
0 to 95% operating and non-operating
Panel Weight
56-termination panels
23 lbs. (10.4 kg)
64-termination panels
24 lbs. (11.3 kg)
84-termination panels
25 lbs. (10.9 kg)
Accessories
Rear View, Connectorized Panel
© Telect, Inc., All Rights Reserved, 11.10.11/rev.5
1.509.926.6000 :: telect.com
2
Description
Part Number
Single conductor Blue NickelTM patch
cord
040-1000-xxx (xxx=feet)
Dual conductor Blue NickelTM patch
cord
040-2000-xxx (xxx=feet)
Looping plug
040-3000-0000RC
100-Ohm Bantam terminating plug
040-5000-0100
5-Conductor cross-connect wire, 1000 ft.
060115RC
Bantam circuit guard plug, white
101222-2
Bantam circuit guard plug, red
101222-3
“Phoney” plug, black
101235-1
“Phoney” plug, red
101235-3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising