Digital multimeter MD 9070 Insulation / Continuity Digital

Digital multimeter MD 9070 Insulation / Continuity Digital
NEW
Digital multimeter
MD 9070 Insulation / Continuity Digital Multimeter
The MD 9070 is a high accuracy
insulation and continuity
multimeter which may be used
in a CAT IV / 600 V environment.
It's dual digital display provides
all needed data to the operator
while it's size ensures that it can
be operated single handedly.
The instrument is equipped
with a built-in VFD feature
that makes the instrument
capable of measuring true
RMS values in accordance with
frequency, performing PI/DAR
measurements and diode test.
The MD 9070 has a wide range
of extra features, including
data hold, memory, min / max,
differential, auto power off,
auto-ranging, frequency filter,
lock feature, reset, relative
function and more.
MEASURING FUNCTIONS
•TRMS measurement;
•Insulation resistance measurement;
•Earth continuity measurement;
•Resistance measurement;
•Diode test;
•Mains supply frequency measurement.
KEY FEATURES
•TRMS for accurate readings of sinusoidal and
non-sinusoidal signals.
•PI/DAR feature.
•VFD feature makes the instrument capable
of measuring the true values in accordance
with frequency.
•Auto-ranging.
•Relative zero for comparing the difference
between signals or removing background
noise.
•MAX/MIN/AVG function.
•Data Hold feature freezes the display for
later view.
•CAT IV / 600 V and CAT III / 1000 V
overvoltage protections.
•Backlight for working in dark conditions.
APPLICATION
•Insulation and earth continuity tester for
preventive maintenance;
•High level industrial testing;
•High level electronic fault finding;
•Field servicing;
•Heavy duty electrical testing.
STANDARDS
•CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0
•EN61326-1:2006
•EN55022
•EN61000-3-2
•EN61000-3-3
•EN61000-4-2
•EN61000-4-3
•EN61000-4-4
•EN61000-4-5
•EN61000-4-6
•EN61000-4-8
•EN61000-4-11
•IEC/UL/EN61010-1 Ed. 3.0
•IEC/EN61010-2-030 Ed. 1.0
•IEC/EN61010-2-033 Ed. 1.0
•IEC/UL/EN61010-031 Ed. 1.1
•IEC/EN61557-1
•IEC/EN61557-2
•IEC/EN61557-4
Directives
•2004/108/EC EMC
•2006/95/EC LVD
www.metrel.si
TECHNICAL SPECIFICATION
ORDERING INFORMATION
Function
Range
Accuracy
TRMS AC Voltage (50 Hz ~ 5 kHz)
6.000 V … 1000 V
From ±(1.0% of reading + 3 digits) to
±(4.0% of reading + 5 digits)
VFD AC Voltage (10 Hz ~ 440 Hz)
600.0 V
From ±(4.0% of reading + 5 digits) to
±(7.0% of reading + 5 digits)
DC Voltage
6.000 V … 1000 V
From ±(0.2% of reading + 3 digits) to
±(0.3% of reading + 3 digits)
Ohms
600.0 Ω … 60.00 MΩ
From ±(0.9% of reading + 2 digits) to
±(3.0% of reading + 6 digits)
Audible Continuity Tester
between 20 Ω and 200 Ω
Response time < 30 ms
Diode Tester
2.000 V
±(1.5% of reading + 4 digits)
Earth Continuity Test
0.015 Ω … 2.199 Ω at Itest > 200 mA
0.15 Ω … 21.99 Ω at Itest > 90 mA
±(1.5% of reading + 3 digits)
±(1.5% of reading + 3 digits)
Hz Line Level Frequency
10 Hz … 440 Hz; range VFD 600 V
10 Hz … 20 kHz; range 6 V … 1000 V
±(0.02% of reading + 4 digits)
±(0.02% of reading + 4 digits)
Insulation Resistance
3.000 MΩ … 55.0 MΩ at 50 V
3.000 MΩ … 110.0 MΩ at 100 V
3.000 MΩ … 275.0 MΩ at 250 V
3.000 MΩ … 550.0 MΩ at 500 V
3.000 MΩ … 300.0 MΩ at 1000 V
3000 MΩ at 1000 V
25.0 GΩ at 1000 V
±(1.5% of reading + 5 digits)
±(1.5% of reading + 5 digits)
±(1.5% of reading + 5 digits)
±(1.5% of reading + 5 digits)
±(1.5% of reading + 5 digits)
±(2.0% of reading + 5 digits)
±(10.0% of reading + 5 digits)
Sensing
AC, True RMS.
Overload Protections
Insulation Resistance: 0.4 A / 1 KV, IR 30 kA or better
Earth Continuity Test: 0,25 A /1 KV, IR 30 kA or better.
V: 1100 Vrms.
mV, Ω & Others: 1000 Vrms.
Power Supply
Four Alkaline AA batteries (IEC LR6).
Power Consumption
4.5mA typical
Dimension (L x W x H)
208 x 103 x 64,5 mm with holster.
Weight
635 g with holster.
METREL D.D.
Measuring and Regulation Equipment Manufacturer
Ljubljanska 77, SI-1354 Horjul, Slovenia
T +386 (0)1 75 58 200, F +386 (0)1 75 49 226
metrel@metrel.si, www.metrel.si
Note! Photographs in this catalogue may slightly differ from the instruments at the time of delivery.
Subject to technical change without notice.
Standard set MD 9070
• Multimeter MD 9070 with rubber holster
• Test lead with probe, 2 pcs
• Insulated crocodile clip, 2 pcs
• Insulation/Continuity test lead with probe,
1 pcs
• 1,5 V AA battery (IEC LR6), 4 pcs
• User manual
OPTIONAL ACCESSORIES
Photo
Order No.
Acc. decription
AMD 9022
Magnetic Hanging
Strap