FLEXtra® twinRepeater, PROFIBUS Repeater

FLEXtra® twinRepeater, PROFIBUS Repeater
50
PROFIBUS Repeater
Catalog 12
FLEXtra® twinRepeater, PROFIBUS Repeater
Features
•
•
•
•
•
•
•
Can be used as bus extension or as a spur line
Increases the number of stations on the bus
System expansion
Can also be used in MPI networks
Status LEDs per segment
Repeater function can be deactivated
Electrical isolation
FLEXtra® twinRepeater
Despite its compact size, the new FLEXtra® twinRepeater from Systeme Helmholz GmbH is a fully functioning PROFIBUS repeater.
It is designed for mounting on a DIN rail.
The FLEXtra® twinRepeater regenerates the electrical signal arriving on the bus line and retransmits it (bit reshaping and retransmission). The level, edge steepness, and mark-to-space ratio of
the signals are reproduced exactly. It supports transmission rates
from 9.6 kbps to 12 Mbps and automatically detects them.
The twinRepeater offers an excellent method of extending the
bus (up to 1 km with 2 FLEXtra® twinRepeaters), increasing the
number of stations, and expanding the system. Moreover, it can
be used in MPI networks. In particular, the FLEXtra® twinRepeater
can be used to implement spur lines as independent segments.
The status LEDs integrated for each segment provide a clear
overview of the current bus status. What is more, the FLEXtra®
twinRepeater electrically isolates the two PROFIBUS segments
from each other.
The twinRepeater also has a switch for deactivating the repeater
function. This separates the segments, which nevertheless each
remain able to function. PROFIBUS connectors are required for
connection to the PROFIBUS cable (also available as a set).
Technical Data
Dimensions (D x W x H mm)
35 x 44 x 72
Weight
Approx. 110 g
Power supply
18 ... 30 VDC
Output voltage
5V
Potential separation
Current consumption
500 V
max.
Segment connection
Ordering Data
Order No.
FLEXtra® twinRepeater
(incl. instruction)
700-972-2AA02
FLEXtra® twinRepeater Set
FLEXtra® twinRepeater, 2 PROFIBUS
Connectors screw terminals 90° with
PG (incl. instruction)
700-972-2XA02
PROFIBUS interface
Transmission rate
60 mA
Via PROFIBUS
Connector
max.
12 Mbps
autodetection
Protocol
PROFIBUS-DP to
EN 61 158-2
Ambient temperature
Transport and storage temperature
0 °C ... +60 °C
-25 °C ... +75 °C
Degree of protection
IP 20
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
PROFIBUS Repeater
Catalog 12
FLEXtra® twinRepeater, PROFIBUS Repeater
PLC
PROFIBUS Slave
PC
...
FLEXtra twinRepeater
®
“R” ON
“R” ON
“R” OFF
“R” ON
Subnetwork 1
up to 32 stations
...
“R” ON
Subnetwork 2
up to 32 stations
Application example FLEXtra® twinRepeater with more than 32 stations
PROFIBUS Slave
PROFIBUS Slave
PC
PLC
...
FLEXtra twinRepeater
®
“R” ON
“R” ON
“R” OFF
“R” OFF
“R” OFF
Subnetwork 1
up to 32 stations
...
“R” ON
PROFIBUS Slave
PROFIBUS Slave
PC
“R” OFF
“R” OFF
“R” ON
Subnetwork 2
up to 32 stations
Application example FLEXtra® twinRepeater with spur lines
PROFIBUS Slave
PLC
FLEXtra® twinRepeater
FLEXtra® twinRepeater
up to 1000 m
(similarly at 12 MBit)
“R” ON
“R” ON
“R” ON
“R” ON
“R” ON
“R” ON
Application example FLEXtra® twinRepeater with long distances
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
51
52
PROFIBUS Repeater
Catalog 12
FLEXtra® multiRepeater 4-way/6-way, PROFIBUS Repeater
Features
•
•
•
•
•
•
•
Building star networks
Plant expansion up to 6 segments with a single device
Increased number of stations on the bus
Deployable for bus extension or as a spur line
Can also be used in MPI networks
Status LEDs for each segment
Repeating function can be deactivated for each segment
or completely
• Electrical isolation of all segments
FLEXtra® multiRepeater 4-way, 6-way
The new FLEXtra® multiRepeater from Systeme Helmholz GmbH
is a multiple PROFIBUS Repeater. It is designed to be mounted on
a DIN rail. The FLEXtra® multiRepeater regenerates the electrical
signal arriving on a bus cable and retransmits it (bit reshaping
and retransmission).
The level, edge steepness and mark-to-space ratio of the signals
are reproduced exactly. It supports transmission rates of 9.6 kbps
to 12 Mbps and detects the rate automatically.
The multiRepeater can be used to extend the bus, to increase
the number of stations on the bus, and to expand the plant. Use
in MPI networks is also possible. As a special application, the
FLEXtra® multiRepeater enables a star network with autonomous
segments. The status LEDs integrated for each segment provide a
fast overview of the bus status.
Moreover, the FLEXtra® multiRepeater ensures electrical isolation
between the PROFIBUS segments. The multiRepeater also has a
DIP switch for disconnecting individual segments and a switch
for disconnecting all segments. The segments are disconnected
but each segment remains separately functional. PROFIBUS connectors are required for connection to the PROFIBUS cable.
Technical Data
4-way
6-way
Dimensions
(D x W x H mm)
35 x 94 x 72
35 x 137 x 72
Weight
Approx. 180 g
Approx. 275 g
Power supply
18 ... 30 VDC
18 ... 30 VDC
Output voltage
5 V, 150 mA per
Segment
5 V, 150 mA per
Segment
Potential separation
500 V
500 V
Current consuption
max. 280 mA
Segment connection
Ordering Data
Via PROFIBUS
Connector
PROFIBUS interface
Transmission rate max. 12 Mbps
autodetection
12 Mbps
autodetection
Protocol
PROFIBUS-DP to
EN 61 158-2
PROFIBUS-DP to
EN 61 158-2
Surrounding air temp.
Transport and storage
temperature
0 °C ... +60 °C
0 °C ... +60 °C
-25 °C ... +75 °C
-25 °C ... +75 °C
Degree of protection
IP 20
IP 20
Order No.
FLEXtra® multiRepeater 4-way
(incl. instruction)
FLEXtra® multiRepeater 6-way
(incl. instruction)
700-972-4AA02
700-972-6AA02
400 mA
Via PROFIBUS
Connector
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
PROFIBUS Repeater
Catalog 12
FLEXtra® multiRepeater 4-way/6-way, PROFIBUS Repeater
FLEXtra® multiRepeater 4-way
drive
PROFIBUS
Slave
PROFIBUS
Slave
PLC
“R” ON
“R” ON
“R” ON “R” OFF
“R” OFF
“R” ON
“R” ON
“R” ON
PROFIBUS
Slave
operator panel
“R” OFF
“R” OFF
FLEXtra® profiPoint
“R” ON
PLC
“R” ON
Application example FLEXtra® multiRepeater 4-way
FLEXtra® multiRepeater 6-way
PLC
“R” ON
“R” ON
“R” ON
“R” ON
“R” ON
“R” ON
“R” ON
PLC
PROFIBUS Slave
“R” ON
“R” ON
PROFIBUS Slave
“R” ON
operator panel
“R” ON
PLC
“R” ON
Application example FLEXtra® multiRepeater 6-way
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
53
54
PROFIBUS Repeater
Catalog 12
PROFIBUS Compact Repeater
Features
• A real alternative to conventional PROFIBUS
repeaters
• No additional space needed in the cabinet
• Very flexible in its use
• Can be used as a bus extension or spur line
• Increases the number of stations on the bus
• System expansion
• Can also be used in MPI networks
• Status LEDs
• 24 V supply is not necessary
• 5 V power supply direct from the PROFIBUS,
with that it’s usable on every PROFIBUS device
• Electrical isolation
PROFIBUS Compact Repeater
The new PROFIBUS Compact Repeater from Systeme Helmholz
GmbH is a fully functional PROFIBUS repeater. It is applicable
very flexible thanks to it’s very small style.
The repeater covers transmission rates from 9.6 Kbps to 12 Mbps.
The transmitted signals are regenerated by the repeater and resent
(Bit-Reshaping and Retransmission), so trouble in the line are
mostly avoided.
In term of price as well as in term of technical reasons the
PROFIBUS Compact Repeater is a real option for multitude applications instead of using standard repeaters.
It can be used for bus extensions (up to 1 km with 2 PROFIBUS
Compact Repeaters), increasement of the stations as well as for
plant extensions.
The operation in MPI networks is also possible.
As a special application option the PROFIBUS Compact Repeater
offers you the possibility the usage of drop cables as standalone
segments. Therefore it can be plugged directly on the PG port of a
built in PROFIBUS connector.
Due to the compact shape no additional room is needed in the
cabinet, as the PROFIBUS Compact Repeater can be used instead
of PROFIBUS Connector, or simply plugged onto a node in the
PROFIBUS Network.
Furthermore no separate power supply is needed, as the
PROFIBUS Compact Repeater is using the 5 V power supply, every
PROFIBUS device possesses for the terminating resistor. The
PROFIBUS Compact Repeater generates an isolation between
both PROFIBUS segments. The integrated status LEDs provide a
fast overview on the current Bus status.
Ordering Data
Transmission Rate
max. segment length
9.6 kbps
1000 m
19.2 kbps
1000 m
45.45 kbps
1000 m
93.75 kbps
1000 m
187.5 kbps
1000 m
500 kbps
400 m
1.5 Mbps
200 m
3 Mbps
100 m
6 Mbps
100 m
12 Mbps
100 m
Technical Data
Dimensions (D x W x H mm)
64 x 40 x 17
Weight
Approx. 40 g
Power supply
Voltage
Current consumption
+ 5 V DC
typ.
Connection
PROFIBUS interface
Transmission rate
100 mA
SUB-D, 9-way
max.
9.6 kbps to 12 Mbps
autodetection
Protocol
PROFIBUS-DP per
EN 50 170
Connection
SUB-D, 9-way
Max. outside diameter
8.0 mm
PROFIBUS cable
60/70 °C copper wire
up to 1.0 mm2
Connection type
4 terminals
Order No.
Environmental pollution degree
2
PROFIBUS Compact Repeater
(incl. instruction)
700-972-0RB12
Ambient temperature
Transport and storage temperature
0 °C ... +60 °C
-25 °C ... +75 °C
Stripping tool for PROFIBUS
700-972-6AA00
Degree of protection
IP 20
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
PROFIBUS Repeater
Catalog 12
55
PROFIBUS Compact Repeater
PROFIBUS
device
PLC
SUB-D female connector
Repeater 1
Subnetwork 1
up to 32
stations in
Subnetwork 1
SUB-D male connector
5V
GND
+
Repeater
+
electrical isolation
“R” ON
PROFIBUS
device
PROFIBUS
device
Subnetwork 2
Repeater 2
Subnetwork 3
up to 32
stations in
Subnetwork 3
max. 1000 m
B1
A1
B2
A2
“R” ON
Internal Design
Application example with long distances
PLC
PC
PROFIBUS device
PROFIBUS device
PROFIBUS device
...
Compact
Repeater
“R” ON
“R” OFF
“R” OFF
“R” OFF
“R” OFF
...
“R” ON
Subnetwork 1
up to 32 stations
PROFIBUS device
PROFIBUS device
“R” OFF
“R” OFF
PC
“R” ON
Subnetwork 2
up to 32 stations
Application example with spur lines
PLC
PC
PROFIBUS device
PROFIBUS device
...
Compact
Repeater
“R” ON
“R” ON
Subnetwork 1
up to 32 stations
“R” OFF
...
“R” ON
Subnetwork 2
up to 32 stations
Application example with more than 32 stations
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
56
PROFIBUS Radio System
Catalog 12
viBlu, PROFIBUS Radio System
Features viBlu 200
•
•
•
•
•
•
•
•
The accessories depicted here are
not included in the scope of supply!
Settable transmission power
Up to 3 radio slaves on one radio master
Bluetooth in the license-exempt 2.4 GHz band
Up to 1.5 Mbps PROFIBUS-DP
Simple configuration via USB interface
No configuration necessary in STEP1) 7
Extensive diagnostics of the radio interface
Ranges extending to over 100 m
Features viBlu 100
As for viBlu 200 but with following reservations:
• Only 1 DP-slave
• Only up to 187.5 kbps PROFIBUS-DP
viBlu, PROFIBUS radio system
The PROFIBUS radio system viBlu is a virtual cable that permits
the linking of distributed I/Os or intelligent devices (e.g. rotating
tables, conveyor systems, etc.) by means of radio.
Data transmission is performed via Bluetooth in the license-exempt 2.4 GHz band and supports the PROFIBUS baud rates of 9.6
kbps to 1.5 Mbps.
Depending on the local circumstances, transmission distances of
up to 100 m are possible.
Use of the PROFIBUS radio module is possible in single-master,
and in multi-master systems and permits full PROFIBUS expansion. At present, only PROFIBUS-DP-slaves are supported behind a
viBlu slave.
The PROFIBUS radio module is powered with 24 V DC from an
external power supply.
A 9-way SubD socket is used for the PROFIBUS connection. Moreover, an USB port is integrated to be used for parameterization of
the radio link.
5 LEDs on the device provide information about the operating
status on the PROFIBUS and on the radio side.
Antennas with a larger gain can optionally be connected to the
radio module through an RP-SMA socket on the device to optimize the range.
Outside Europe, use of antennas with a gain of more than 10 dBi
is permitted, enabling radio-relay systems with a range, for example, of up to a few kilometers.
Accessory-Note
For antennas, see page 60.
viBlu 100
viBlu 200
Dimensions
(D x W x H mm)
130 x 68 x 30
130 x 68 x 30
Weight
Approx. 170 g
Approx. 170 g
Power supply
Voltage
DC 24 V (18 ... 30 V) DC 24 V (18 ... 30 V)
Current
consumption
Typ. 100 mA
Typ. 100 mA
PROFIBUS
Type
RS485, isolated
RS485, isolated
Number of DP/slaves 1 slave
3 slaves
Transmission rate
9.6 kbps ... 187.5
9.6 kbps ... 1.5
kbps, autodetection Mbps, autodetection
Connection
SUB-D, 9-way
SUB-D, 9-way
Radio interface
Protocol
Bluetooth
Bluetooth
Range
Up to more than
100 m
Up to more than
100 m
700-761-PFS11
700-762-PFM11
Baud rate
Up to 700 kbps
Up to 700 kbps
Antenna connection RP-SMA socket
RP-SMA socket
700-762-PFS11
Ambient
temperature
0 °C ... 60 °C
0 °C ... 60 °C
Indicators
5 LEDs
5 LEDs
Ordering Data
Order No.
viBlu 100 Master*
connection up to 1 Slave; 187.5 kbps
viBlu 100 Slave*
viBlu 200 Master*
connection up to 3 Slaves; 1.5 Mbps
viBlu 200 Slave*
Technical Data
700-761-PFM11
*(incl. manual, CD with software)
1) STEP is a registered trademark of Siemens AG.
Degree of protection IP 20
IP 20
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
PROFIBUS Radio System
Catalog 12
viBlu, PROFIBUS Radio System
PROFIBUS Slave
PLC
PROFIBUS Slave
PROFIBUS max. 1.5 Mbps
PROFIBUS Slave
PAS 153
viBlu 200 Slave
viBlu 200 Master
PROFIBUS
Application example viBlu 200 with a radio slave and up to 3 PROFIBUS-DP stations
PLC
PROFIBUS Slave
viBlu 200 Slave
PROFIBUS Slave
PROFIBUS
PROFIBUS max. 1.5 Mbps
PROFIBUS Slave
viBlu 200 Slave
PROFIBUS
PAS 153
viBlu 200 Master
viBlu 200 Slave
PROFIBUS
Application example viBlu 200 with 3 radio slaves
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
57
58
PROFIBUS Radio System
Catalog 12
PAS 153 viBlu, distributed PROFIBUS Radio Interface
Features PAS 153 viBlu 200
•
•
•
•
•
•
•
•
•
•
•
•
Up to 16 modules can be plugged in
Module diagnostics supported
Can be used on standard Mounting rail
Any combination of modules is possible (analog/digital)
GSD file is supplied
Settable transmission power
Up to 3 slaves in the radio network
Bluetooth in the license-exempt 2.4 GHz band
Up to 1.5 Mbps PROFIBUS-DP
Simple configuration of the radio parameters through USB
Extensive diagnostics of the radio interface
Ranges extending to over 100 m
Features PAS 153 viBlu 100
As for the PAS 153 viBlu 200, but with the following restrictions:
• Only 1 DP slave in the radio network
• Only up to 187.5 kbps PROFIBUS-DP
PAS 153 viBlu, distributed PROFIBUS radio interface
The PAS 153 viBlu distributed PROFIBUS radio interface from Systeme Helmholz GmbH is for linking digital and analog input and
output modules to the PROFIBUS-DP by radio. Data transmission
is performed via Bluetooth in the license-exempt 2.4 GHz band
and supports the PROFIBUS baud rates of 9.6 kbps to 1.5 Mbps.
Depending on the local circumstances, transmission distances of
up to 100 m are possible.
Up to 16 modules can be connected to the PAS 153. The PAS 153
viBlu is integrated into the Hardware Configurator of the programming system by a GSD file. The PAS 153 Interface performs
all communication between the modular I/O device and the
higher-level master unit on the PROFIBUS-DP. The inputs and
outputs are assigned to the master in the configuration. Diagnostic information from the modules can be read out via the PAS 153
Interface in the usual way.
The PAS 153 viBlu radio interface supports all input/output modules from Systeme Helmholz GmbH and numerous modules of
the same type from other manufacturers.
The scope of modules supported can be extended at any time by a
firmware update via the USB.
Antennas with a larger gain can optionally be connected to the
radio module through an RP-SMA socket on the device to optimize the range. Outside Europe, use of antennas with a gain of
more than 10 dBi is permitted, enabling radio-relay systems with
a range, for example, up to several kilometers.
Moreover, a USB port is integrated to be used for parameterization
of the radio link.
6 LEDs on the device provide information about the operating
status on the PROFIBUS and on the radio side.
Accessory-Note
For antennas, see page 60.
PAS 153 viBlu 100
PAS 153 viBlu 200
Dimensions in
mm (D x W x H)
116 x 40 x 125
116 x 40 x 125
Weight
Approx. 270 g
Approx. 270 g
Power supply
Voltage
24 V DC (18 ... 30 V)
Order No.
700-763-PFS11
700-764-PFS11
24 V DC (18 ... 30 V)
Current consumption Typ. 700 mA
Typ. 700 mA
Output voltage
5V
5V
Output current at
max. 1.5 A
5 V DC (for backplane bus)
1.5 A
(for backplane bus)
Number of modules
max. 16, including
8 analog
16, including
8 analog
Addressing range
128 bytes for inputs 128 bytes for inputs
128 bytes for outputs 128 bytes for outputs
PROFIBUS
PROFIBUS-DP per
EN 50 170
PROFIBUS-DP per
EN 50 170
Transmission rate
9.6 kbps to 187.5
kbps, detected
automatically
9.6 kbps to 1.5
Mbps, detected
automatically
Connection type
SUB D socket, 9-way SUB D socket, 9-way
Radio interface
Protocol
Bluetooth
Number of slaves on
the radio network
1 slave
Ordering Data
PAS 153 viBlu 100
(incl. manual, CD with software)
PAS 153 viBlu 200
(incl. manual, CD with software)
Technical Data
Bluetooth
3 slaves
Range
Up to more than
100 m
Baud rate
Up to 700 kbps
Up to 700 kbps
Antenna connection RP-SMA socket
RP-SMA socket
Ambient temperature
Transport and
storage temperature
Displays
0 °C ... +60 °C
Up to more than
100 m
0 °C ... +60 °C
-25 °C ... +60 °C
-25 °C ... +60 °C
6 LEDs
6 LEDs
Degree of protection IP 20
IP 20
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
PROFIBUS Radio System
Catalog 12
PAS 153 viBlu, distributed PROFIBUS Radio Interface
PLC
PROFIBUS max. 1.5 Mbps
PROFIBUS Slave
PAS 153 viBlu 100
viBlu 100 Master
Application example PAS 153 viBlu 100 with 1 Slave
PLC
PROFIBUS max. 1.5 Mbps
PROFIBUS Slave
PAS 153 viBlu 200
PAS 153 viBlu 200
viBlu 200 Master
PAS 153 viBlu 200
Application example PAS 153 viBlu 200 with 3 Slaves
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
59
PROFIBUS Radio System
Catalog 12
Antennas for NETL ink® WLAN and viBlu
Height:
30 mm
10
192 mm
m
7m
Ø max.13 mm
Cable 1.5 m
m
94 m
N-type/female
5 dBi magnetic base antenna
Panel 8 dBi antenna
Height:
50 mm
26
Ø 20 mm
3m
m
390 mm
60
N-type/female
263
mm
N-type/female
Omni 8 dBi antenna, including wallclamp
Panel 18 dBi antenna
To optimize the reception power of the NETL ink® WLAN and the
PROFIBUS radio system viBlu, Systeme Helm­holz GmbH can provide a selection of different antennas. Depending on the design,
connecting cables can be procured to match. When planning a
radio link, it is important always to note that, both in a mobile
and in a stationary installations, the range is to some degree
influenced by obstacles and the surrounding structures. Due to
the max. transmission power of 100 mW in the 2.4 GHz band,
radio links of 10 to 30 meters can be implemented in buildings.
Outdoors, 100 to 300 meters can be considered realistic for an
unobstructed radio link. With a directed panel antenna, more
than 300 meters are possible in optimum conditions.
Magnetic base antenna 5 dBi
For mounting on smooth magnetic surfaces. The permanently
mounted 1.5 meter long connecting cable further increases the
radius of action. The magnetic base can be unscrewed. In this
way, the dipole can also be directly operated on the WLAN module and is especially suitable for unobstructed mid-distance links.
The omnidirectional antenna can also be correctly aligned with
the integrated knee-joint.
Ordering Data
Order No.
2.4 GHz 5 dBi magnetic base antenna,
with 1.5 m antenna cable
2.4 GHz Omni 8 dBi antenna
(antenna cable required)
2.4 GHz Panel 8 dBi antenna
(antenna cable required)
2.4 GHz Panel 18 dBi antenna
(antenna cable required)
2.4 GHz antenna cable, 3 m; 1.7 dB; Ø 5 mm
2.4 GHz antenna cable, 5 m; 2.8 dB; Ø 5 mm
2.4 GHz antenna cable, 6 m; 1.4 dB; Ø 10.3 mm
2.4 GHz antenna cable, 10 m; 2.3 dB; Ø 10.3 mm
700-889-ANT01
700-889-ANT02
700-889-ANT03
Omnidirectional antenna 8 dBi
This omniantenna protected by the stable GFK conduit is supplied with mounting brackets to be able to mount it on masts or
walls – preferably outdoors. To obtain the best omnidirectional
emission properties, there should be no metallic surfaces or obstructions near to the emitting antenna. A cable, available as an
accessory, is required for a type N connection.
Panel antenna 8 dBi (wall mounting) and panel antenna 18 dBi
(mast mounting)
Ideal for use in directional transmission and reception indoors
and outdoors. The range and WLAN performance are considerably improved by this design. The appropriate fixtures are
supplied. A cable, available as an accessory, is required for a type N
connection.
700-889-ANT04
700-889-ANK01
700-889-ANK02
700-889-ANK03
700-889-ANK04
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
PROFIBUS Communication
Catalog 12
PAS 153, distributed PROFIBUS Interface
Features
•
•
•
•
•
•
•
•
DIP switch for setting the PROFIBUS address
Up to 16 modules can be plugged in
Module diagnostics supported
Can be used on standard sectional rail
Any combination of modules is possible (analog/digital)
PROFIBUS-DP up to 12 Mbps
GSD file is supplied
Firmware update for expanding functions possible via
USB
Up to 16 modules can be plugged in
PAS 153
The PAS 153 distributed PROFIBUS Interface from Systeme Helmholz GmbH is for linking digital and analog input and output
modules to the PROFIBUS-DP. The module can be mounted on a
sectional rail.
Up to 16 modules can be connected to the PAS 153. The PAS 153
is integrated into the hardware configurer of the programming
system by a GSD file. The PAS 153 Interface performs all communication between the modular I/O device and the higher-level
master unit on the PROFIBUS-DP. The inputs and outputs are assigned to the master in the configuration. Diagnostic information
from the modules can be read out via the PAS 153 Interface in the
usual way.
The PAS 153 Interface supports all input/output modules from
Systeme Helmholz GmbH and numerous modules of the same
type from other manufacturers.
The scope of modules supported can be extended at any time by a
firmware update via the USB.
Technical Data
Dimensions (D x W x H mm)
116 x 40 x 125
Weight
Approx. 250 g
Power supply
Voltage
DC 24 V
Current consumption
max.
Output voltage
625 mA
DC 5 V
Output current at DC 5 V
max.
1.5 A (to backplane)
PROFIBUS Interface
Transmission rate
max.
12 Mbps,
autodetection
Protocol
PROFIBUS-DP
to EN 50 170
Addressrange
128 Bytes for inputs
128 Bytes for outputs
Ordering Data
Order No.
Module count
max.
16.8 of these analog
PAS 153, distributed PROFIBUS Interface (incl. CD with GSD file)
700-153-1AA03
Connection
Male, SUB-D, 9-way
Manual PAS 153, German/English
900-153-1AA03
Ambient temperature
Transport and storage temperature
0 °C ... +60 °C
-25 °C ... +60 °C
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
61
PROFIBUS Communication
62
Catalog 12
DP/DP Coupler
Features
• Up to 244 Bytes of input data and 244 Bytes of output
data can be exchanged between two PROFIBUS networks
• Dual-redundant power supply
• Electrical isolation between the PROFIBUS networks
• PROFIBUS addresses can be set by DIL switch or software
• PROFIBUS-DP up to 12 Mbps
Technical Data
Dimensions (D x W x H mm)
116 x 40 x 125
Weight
Approx. 250 g
Power Supply
Nominal power supply
Current consumption
24 V DC (20.4 V... 28.8 V)
Approx. 150 mA at DC
24 V
Electric isolation of the 24 V power
supply
To PROFIBUS-DP
Yes
Mutually
Yes
DP/DP Coupler
PROFIBUS interface
Transmission rate
9.6 ... 12 Mbps
The DP/DP coupler interlinks two PROFIBUS-DP networks and
permits data transmission between the masters and the two DP
networks. The maximum size of the transmitted data is 244 Bytes
of input data and 244 Bytes of output data. The DP/DP coupler is
configured in the S7 software or by means of a GSD file.
Protocol
PROFIBUS-DP
Telegram length I/O data
Max. 244 Bytes inputs/
244 Bytes outputs
Ambient temperature
0 °C ... 60 °C
Degree of protection
IP 20
PG
PLC
PLC
Systeme Helmholz
PROFIBUS-DP net 2
PROFIBUS-DP net 1
DP/DP
coupler
DP/DP coupler
operator panel
PROFIBUS slave
Application example DP/DP Coupler
Ordering Data
Order No.
DP/DP Coupler (incl. manual)
700-158-0AD01
Mounting rail adapter for DIN rail
(optional)
Mounting rail 40 mm
700-390-6BA01
700-390-1XA04
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
PROFIBUS Accessory
Catalog 12
63
FLEXtra® profiPoint, active Termination and Measuring Point
Features
• Power supply independent of bus stations
• Bus termination independent of terminal device due to
autonomous power supply
• Can be used as an active measuring point
• Supply to active PROFIBUS components (Compact
Repeater, NETL ink®, PROFIBUS diagnostic connector)
FLEXtra® profiPoint
The new FLEXtra® profiPoint from Systeme Helmholz GmbH is
primarily used for supplying power to the terminating resistor
and is designed for mounting on a DIN rail. It can be used in
combination with a PROFIBUS connector as an active measuring
point or as an active termination. The electric power is supplied
independently of the bus stations via a connection socket.
If used as an active terminating resistor, bus system stations can
be coupled and decoupled randomly without faults occurring.
The correct function of the FLEXtra® profiPoint can be read from
an integrated LED. A PROFIBUS connector is required for connection to the PROFIBUS cable (also available as a set).
PLC
PLC
as a terminating resistor
“R” ON
PROFIBUS
Slave
FLEXtra® profiPoint
FLEXtra® profiPoint
“R” OFF
“R” OFF
as a measuring point
PROFIBUS
Slave
FLEXtra® profiPoint
as a terminating resistor
“R” OFF
“R” OFF
“R” OFF
“R” ON
Application example FLEXtra® profiPoint
Technical Data
Ordering Data
Order No.
FLEXtra® profiPoint (incl. instruction)
700-972-1AA02
FLEXtra® profiPoint Set
FLEXtra® profiPoint, PROFIBUS connector screw terminals 90° diagnostic
LEDs with PG (incl. instruction)
700-972-1XA02
Dimensions (D x W x H mm)
35 x 32 x 72
Weight
Approx. 85 g
Power supply
18 ... 30 VDC
Output voltage
24 VDC/5 VDC
Potential separation
500 V
Current consumption
max.
400 mA
Segment connection
Via
PROFIBUS connector
Ambient temperature
Transport and storage temperature
0 °C ... +60 °C
-25 °C ... +75 °C
Degree of protection
IP 20
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com
64
PROFIBUS Accessory
Catalog 12
Active PROFIBUS Dropcable
Programmable controller
Slave
MPI/PROFIBUS
Active Dropcable
PG/PC
Application example Active Dropcable
Dropcable PROFIBUS for PG
The active PROFIBUS dropcable from the Systeme Helmholz
GmbH is used for a failure-free connection of a programming
device to an existing PROFIBUS net.
The active cable doesn‘t represent a spur line because of it‘s integrated electronics.
Technical Data
Dimensions (length)
3m
Weight
Approx. 260 g
Power supply
Ordering Data
Order No.
Dropcable PROFIBUS for PG with
90° PROFIBUS connector, 3 m (incl.
instruction)
700-901-4BD00
Dropcable PROFIBUS for PG with
35° PROFIBUS connector, 3 m (incl.
instruction)
700-901-4BD10
DC 5 V
100 mA at 5V
Current consumption
max.
PROFIBUS interface
Transmission
max. 12 Mbps
Connection
SUB-D, 9-way
Ambient temperature
Transport and storage temperature
0 °C ... +60 °C
-25 °C ... +75 °C
Degree of protection
IP 20
Systeme Helmholz GmbH | 91091 Großenseebach | Phone: +49 9135 7380-0 | Fax: +49 9135 7380-110 | Internet: www.helmholz.com