Micro TPASS® Repeater

Micro TPASS® Repeater
Battery Charging LED Display
Safety Certifications
Intrinsically Safe, Sécurité Intrinséque
Charger Adapter
Plugs Into Charging Key
II 1 G Ex ia IIC T4 Ga
0891
TRAC11ATEX11299X
-40°C < TA < 40°C
IP67
FCC ID: J5XT3HEP -- Meets FCC Part 15
IC: 5916A-T3HEP -- Complies with Canadian ICES-003
WARNINGS!
WARNING! Changes or modifications not expressly
approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
WARNING! To prevent ignition of a hazardous
atmosphere, battery must only be charged in an area
known to be nonhazardous.
WARNING! Substitution of components may impair
intrinsic safety.
AVERTISSEMENT! Les changements ou modifications
non expressément approuvés par la partie
responsable de la conformité pourraient annuler
l’autorité de l’utilisateur à utiliser cet équipement.
AVERTISSEMENT! Pour éviter l’inflammation d’une
atmosphère dangereuse, les batterie doivent être
chargées seulement dans une zone connu comme
être non dangereuse.
Micro TPASS® Repeater Rechargeable
with Charging Key in Place
Charge Indicator Light
Green LED
Charging: When the charging key is in place and
plugged into a power source, a Green LED will glow
below the left side button (left side when facing the
Micro TPASS® Repeater).
AVERTISSEMENT! La substitution de composants
peut compromettre la sécurité intrinsèque.
Charging Complete: Unit is fully charged when the
Charge Indicator Light is flashing Green.
FCC Statements
The Low Battery Alarm will sound when the battery
has been exhausted to 20% of capacity (indicating
approx. 1 hour operating time remains). Charging the
battery is necessary when Low Battery Alarm sounds.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
The Low Battery Alarm is an easily recognized series
of two audio beep tones every five seconds when the
Micro TPASS® Repeater is ON.
Grace Industries, Inc. assumes no liability for mechanical, electrical, or other types of battery failure.
Warranty Information
Grace Industries, Inc. warrants the unit to be free from
defects in workmanship and materials for a period of
one year from date of purchase. This warranty is valid
only when the returned unit is accompanied by a sales
receipt or other proof of purchase that states the date
and location of purchase. Grace Industries, Inc. will
not repair or replace any merchandise under warranty
which has been damaged because of accident, misuse
or abuse of the unit while in possession or control of the
consumer or outside of Grace Industries Inc’s control.
This warranty is void if any attempt to repair or replace
parts was made or attempted by other than qualified
Grace Industries, Inc. personnel. This warranty is void if
any of the sealed compartments are opened or tampered
with. Send all returned merchandise, prepaid and
accompanied by proof of purchase to: Grace Industries,
Inc., Repair Division, 305 Bend Hill Road, Fredonia,
PA 16124. Customer is responsible for return shipping.
Grace Industries, Inc. shall not be liable for any direct,
incidental or other consequential loss or damage arising
out of the failure of the device to operate.
The sole and exclusive remedy under all guarantees
or warranties, expressed or implied, is strictly limited to
repair or replacement as herein provided. ALL IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO,
WARRANTIES OF FITNESS AND MERCHANTABILITY,
ARE HEREBY LIMITED IN DURATION TO A PERIOD
ENDING ONE (1) YEAR FROM THE DATE OF
PURCHASE. The warranty and liability set forth in
the prior paragraphs are in lieu of all other warranties,
expressed or implied, in law or in fact, including implied
warranties of merchantability and fitness for a particular
purpose. Some states do not allow limitations on how
long an implied warranty lasts, so the above limitations
may not apply to you.
Micro TPASS
Repeater
®
RECHARGEABLE
USER’S INFORMATION
Only To Be Removed By End User
ATEX
CERTIFIED
Front View
with
Accountability
Key in Place
Grace Industries, Inc.
www.graceindustries.com
Ph. 724-962-9231 • Fax 724-962-3611
This warranty gives you specific legal rights and you
may also have other rights which may vary from state
to state.
The information contained in this booklet is believed
to be accurate and reliable. Grace Industries, Inc.
provides this information as a guide only.
Front View Without
Accountability Key
Micro TPASS® Repeater technical assistance is available by contacting Grace Industries, Inc. at (724) 9629231 or by email at info@graceindustries.com.
For training purposes a copy of this information is
available by contacting Grace Industries, Inc.
Industry Canada Statements
This Class A digital apparatus complies with Canadian ICES-003.
This device complies with Industry Canada licence-exempt
RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference
that may cause undesired operation of the device.
Micro TPASS® Repeater Rechargeable
with Accountability Key in Place
120 VAC Charger Adapter
Cet appareil numérique de la classe A est conforme à la
norme NMB-003 du Canada.(select the class for your device)
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2)
l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
Optional 12 VDC Charger
Adapter Available
www.graceindustries.com
© Grace Industries, Inc.
Printed in U.S.A.
P/N: Micro TPASS Repeater-R ATEX 0317 UI
Solutions for Life Safety
Micro TPASS® Repeater Intrinsically Safe Rechargeable
Micro Repeater Operating Instructions
Always test the unit prior to each use
1. To Reset, press both side
buttons simultaneously when
accountability key is off unit.
2. To turn OFF, replace accountability
key and press both side buttons
simultaneously.
D-Ring
Accountability
Storage Key
Grip Clip
Side View with
Accountability
Key OFF
Side View with
Accountability
Key in Place
Front Button
Not Used
Identification
Window
Gasket Seal
Sound
Port
Charging
Contacts
MICRO TPASS® REPEATER
Micro TPASS® Repeater is a small, lightweight,
portable signaling device that operates
interactively with Grace Confined Space and
Firefighter In-Command® Emergency Signaling
and Accountability Systems.
By receiving and re-transmitting Grace radio
commands, the Micro TPASS® Repeater
enhances the overall system performance over
open distances or within indoor environments
where poor radio propagation is encountered.
Micro TPASS® Repeater is used on both the
Grace legacy Radio-G and Radio-H platforms.
The Micro TPASS® Repeater will only function
on one of these platforms and will only function
on its respective radio platform. Exercise caution
and understand this limitation if attempting to use
the Micro TPASS® Repeater in situations where
mixed Radio-G and Radio-H platforms are used.
The Micro TPASS® Repeater is omni-directional,
very easy to operate, and is the same size as the
TPASS®3. NOTE: Micro TPASS® Repeater IS
NOT a PASS (Personal Alert Safety System).
Micro TPASS® Repeater Operation
To turn the Micro TPASS® Repeater ON, remove
the Accountability Key. An escalating series of
audio tones will be heard indicating the Micro
TPASS® Repeater is ON and operational.
● Micro TPASS® Repeater transmits an ON message.
● Two Red LEDs flash when messages are
received and retransmitted.
● When the Accountability Key is removed during
operation, the Micro TPASS® Repeater will be
silent and two Red LEDs flash when messages
are received and retransmitted.
● When the Accountability Key is replaced during
operation, the audio tone is activated and two
Red LEDs flash when messages are received
and retransmitted.
● The Micro TPASS® Repeater retransmits
check-in, change of status, Alarm and
Evacuation signals.
To turn the Micro TPASS® Repeater OFF, replace
the Accountability Key and momentarily press
both side buttons simultaneously. De-escalating
sweeping audio tones will be heard and LED
activity will cease.
Micro TPASS® Repeater Find Function
By using In-Command® Full Crew or In-Command®
First-In Fire Fighter Emergency Signaling and
Accountability Systems, it is possible to select all
or individual Micro TPASS® Repeaters and send
an EVAC command. The EVAC command acts
as a find function on the Micro TPASS® Repeater.
The Micro TPASS® Repeater will emit a special
audio tone and activate Red flashing LED’s as
a visual indicator. This feature is a tool to collect
the Micro TPASS® Repeater after use on the fire
ground.
Reset or turn the Micro TPASS® Repeater OFF to
clear the Find Function.
Mode Selection
Micro TPASS® Repeater Maintenance
AUTO-ON ACTIVATION
● Remove Accountability Key to automatically
activate the unit.
RESET
● Check-in signals can be sent by
simultaneously pressing both side buttons.
OFF
● Turn OFF Micro TPASS® Repeater by
replacing the Accountability Key (or Charging
Key) and then pressing both side buttons
Micro TPASS® Repeater requires minimum
maintenance and will provide years of service.
Please Observe These Guidelines
● At the end of each use, clean unit with a damp
cloth. DO NOT use cleaning solvents.
● After each use, inspect unit for signs of
physical damage. Remove unit from service
if physical damage is observed.
● Store Micro TPASS® Repeater in a dry, well
ventilated area consistent with battery
manufacturer requirements. Recommended
storage conditions are: 50o to 77oF (10o to
25oC) at no more than 65% relative humidity.
● Units contaminated by chemical or radioactive
materials must be disposed of or decontaminated
in accordance with all applicable regulatory
standards.
● DO NOT mark or apply paint to Micro
TPASS® Repeater.
Visual / Audio Mode Display
OFF
● No LED display.
ON
● A series of escalating, loud audio tones
when turned on.
● Two Red LEDs flash when messages are
received and re-transmitted.
● With Accountability Key in place: Audio
tone is activated when signals are received
and retransmitted.
FIND FUNCTION
● Rapid flashing of top Red LED.
● A loud, alternating audio tone.
Specifications
Dimensions: 2-1/8” wide, by 2-1/4” deep (with clip),
5” high (with antenna)
Weight: 7.3 ounces.
Case: Bright Orange, translucent polycarbonate,
rugged, water resistant, impact resistant and
temperature resistant.
Methods of Attachment: rugged Grip Clip and
D-ring for versatility in attaching to gear.
Antenna: short, threaded antenna for easy
replacement
Battery: Intrinsically safe Lithium-ion.
Battery Life: estimated at 30 hours in ON Mode.
Battery Charging: 120 VAC (standard) or
12VDC (optional adapter required) may be used
Battery Charging Time: 6 to 8 hrs
Battery Charging Cycles: 500
Product Life: Approximately 3 to 5 years or
longer, depending on fitness for use. Fitness for
use is best determined by the end user through
a proper inspection and maintenance program.
Product should be retired from service when
damaged or returned to Grace Industries for
evaluation and repair if applicable.
Limitations
To reduce risk of serious injury or loss of
life, ensure Micro TPASS® Repeater is fully
operational by testing and inspecting the unit
prior to use. Use of a Micro TPASS® Repeater
maintenance and training program including
recharging exhausted or low batteries is
required for safe and proper use.
After charging the Micro TPASS® Repeater,
always test by affixing the Accountability Key
and listening for the transmit and receive “chirp”
sounds that signify the presence of Grace radio
traffic. To generate Grace radio traffic, use the
reset function of the TPASS® or SuperCELL®
SC500; or select the Micro TPASS® Repeater
and initiate an EVAC command from the
In-Command®
Emergency
Signaling
and
Accountability System. Exercise the same
caution as explained in the recognized proper use
of Grace legacy Radio-G and Radio-H platforms.
If proper operation of Micro TPASS® Repeater is
questionable, remove unit from service and
contact Grace Industries for assistance.