CTL-IO-4 Data Sheet - Smart Vision Lights

CTL-IO-4 Data Sheet - Smart Vision Lights
CTL-IO-4
I/O MODULE
Camera to Light
product features

Connection for up to 4 lights

Industry Standard M12 Connection

DIN rail mounting

1 Input, 4 Outputs

Removable Terminal Blocks

Support for NPN and PNP cameras

LED indicators for outputs

Energy Storage for Strobe Lights
product specifications
Electrical Input
24 VDC +/- 5%
Current
Max. 6A continuous :: Max. 24A with 10% duty cycle
Wattage
Max. 144W continuous :: Max. 576W with 10% duty cycle
Fuse Replacement
Slow Blow 8A 5x20, Bel Ruse 5ST 8-R
Strobe Input
PNP ► +4VDC or greater to activate.
│ NPN ► GND (<1VDC) to activate
Green LED Indicator
ON = Power
Amber LED Indicator
ON = Output
CAD image
Smart Vision Lights • 2359 Holton Rd. • Muskegon, MI 49445 •Phone 231.722.1199
www.smartvisionlights.com
inputs
The CTL-IO-4 module provides inputs for triggering LED lights. When the I/O module is connected to a
strobe source or camera system the strobe signal runs up to 4 lights. Input signals can be NPN (sinking)
or PNP (sourcing) from the camera or strobe source. Signals can be selected on what type (NPN or
PNP) is sent to the lights.
Input 1 – M12 Male Connection
Specification
Description
Voltage while ON
4 – 26VDC to activate
Voltage while OFF
0 – 3VDC
Current
8ma
PIN
ASSIGNMENT
1
24VDC
2
NPN or 0-10V
3
GND
4
PNP or NPN
5
Open or 0-10VDC (ANALOG)
Drawing shows male
socket on the I/O Board.
SW2 – Input 1 Pin-out Selector Switch
Dip switch will allow selection of male M12 input connector pins to M12 outputs.
Pin 2 is settable between NPN or 0-10V (only one switch can be ON).
Pin 4 is settable between NPN or PNP (only one switch can be ON).
Pin 5 is settable between OFF for open circuit, or ON to allow 0-10V analog input on Pin 5.
See “Settings for Connection to Cameras” later in this guide for configurations to common cameras.
NOTE: This must be configured before powering the module. If the M12 input connector is not used set
all switches to OFF.
PWM – Pulse Width Modulation
PWM signal: NPN input, 20-100kHz, 95% PWM
input is 100% Light output, 0% input is less than
10% Light output.
Input 2 – Connection
Input 2 is terminal connection in addition to M12
male input. The NPN and PNP inputs connect
directly to the M12 outputs. The 0-10V and PWM
terminals go through the Intensity Control selector
to determine how the output to Pin 5 is controlled.
Smart Vision Lights • 2359 Holton Rd. • Muskegon, MI 49445 •Phone 231.722.1199
www.smartvisionlights.com
outputs
The CTL-IO-4 module provides outputs for 1 to 4 LED lights. When the I/O module is connected to a
strobe source or camera system the I/O board runs up to 4 lights. Lights draw power from the I/O module
and NOT the camera. The 4 Light outputs can draw 6 amps of continuous current or 24 amps of strobe
current from the I/O module.
Out 1 thru 4 – M12 Female Connection
Specification
Description
Voltage while ON
4 – 26VDC to activate
Voltage while OFF
0 – 3VDC
Current
8ma
PIN
ASSIGNMENT
1
24VDC
2
NPN
3
GND
4
PNP
5
0-10VDC (ANALOG)
Drawing shows female
socket on the I/O Board.
Out 5
Output 5 is an option for connecting to un-terminated cables. Connect wires to these terminals as marked
on the module. All outputs are connected in parallel within the CTL-IO-4 module.
SW4 – IN/OUT Strobe Signal Converter
SW4 will select the strobe signal as PNP or NPN to OUT 1-4. The first DIP switch when switched ON, will
translate the NPN input of the CTL-IO-4 module on to the PNP outputs feeding the LED lights. The
second DIP switch translates the PNP input to the NPN outputs. This can be helpful if you are seeing
voltage drop or voltage transient issues in your system wiring.
Smart Vision Lights • 2359 Holton Rd. • Muskegon, MI 49445 •Phone 231.722.1199
www.smartvisionlights.com
intensity control
The CTL-IO-4 module provides selector switch for intensity control. Intensity control can be passed thru
from the camera with a 0-10VDC analog signal or PWM. The I/O module will also set all lights to full
intensity or allow all lights to be adjusted with V1 Potentiometer.
SW3 – Selector Switch
SW3 switch will allow selection of Full Intensity, 0-10V Pass Thru, PWM to 10V and V1 Potentiometer.
Switch controls all 4 outputs intensity.
1.
2.
3.
4.
0-10V Pass Thru
PWM to 0-10V
V1 Potentiometer
Full Intensity
cables
Part Number
Length
5PM12-J300-CTL
0.3 meter
5PM12-J2000-CTL
2 meter
Additional lengths available upon request
Settings for Connection to Cameras
Input 1 DIP Switch:
SVL standard pin out: Set 1, 3, & 5 to ON, and 2 & 4 to OFF
Cognex IS 7000 Camera: Set 1 & 3 to ON, and 2, 4, & 5 to OFF (set intensity control to either Full or Pot)
Cognex DM300 Camera: Set 2 & 3 to ON, and 1 & 5 to OFF
Smart Vision Lights • 2359 Holton Rd. • Muskegon, MI 49445 •Phone 231.722.1199
www.smartvisionlights.com