CFP Conventional Fire Alarm Panel Leaflet

CFP Conventional Fire Alarm Panel Leaflet
TYPICAL WIRING
TYPICAL DETECTOR
CIRCUIT WIRING
TYPICAL SOUNDER
CIRCUIT WIRING
TYPICAL AUX.
OUTPUT WIRING
TYPICAL AUX.
INPUT WIRING
END OF LINE
RESISTOR
(6k8 Ohm)
END OF LINE
CAPACITOR
Relay
Activated
AUXILIARY
FIRE RELAY
SMOKE OR HEAT
DETECTOR
ALERT INPUT
POLARISED
SOUNDER
Relay
Activated
AUXILIARY
FIRE RELAY
range
MANUAL
CALL POINT
POLARISED
SOUNDER
DO NOT SPUR
(wiring not monitored)
SMOKE OR HEAT
DETECTOR
Relay
Activated
AUXILIARY
FIRE RELAY
CLASS CHANGE
INPUT
DO NOT SPUR
(wiring not monitored)
Relay
Activated
POLARISED
SOUNDER
AUXILIARY
FIRE RELAY
GUIDANCE DIAGRAM ONLY
MORE DETAILED WIRING INFORMATION
AVAILABLE ON REQUEST
MANUAL
CALL POINT
Unused detector circuits
should be terminated
with an end of line resistor
Unused detector circuits should be
terminated with an end of line capacitor
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
DETECTOR CIRCUITS
SC1
SC2
SC3
SC4
SOUNDER CIRCUITS
AUX
AUX RESET 24V
REM FAULT
OUTPUTS
0V
ALERT
CC
INPUTS
CFP STANDARD EN54 FIRE PANELS & ANCILLARIES
CFP702-4
CFP standard 2 zone panel, code entry version, does not extend
CFP702-4K
CFP standard 2 zone panel, keyswitch version, does not extend
CFP704-4
CFP standard 4 zone panel, code entry version, does not extend
CFP704-4K
CFP standard 4 zone panel, keyswitch version, does not extend
CFP708-4
CFP standard 8 zone panel, code entry version, does not extend
CFP708-4K
CFP standard 8 zone panel, keyswitch version, does not extend
CFP760
CFP 8 zone repeater panel, up to 8 per system, code entry version
CFP760K
CFP 8 zone repeater panel, up to 8 per system, keyswitch version
CFP761
CFP network driver card (one required per repeater system, fit at main)
CFP762
CFP relay output card (provides reset, fault, aux & remote relay outputs)
CFP763
CFP relay output per zone card (as CFP762 plus 8 output per zone relays)
CFP ECONOMY EN54 FIRE PANELS
Include all CFP standard panel features except coincidence, zone delay and non-latching zone
facilities. CFP economy panels are not compatible with CFP repeaters or CFP relay output cards
CFP702E-4
CFP economy 2 zone panel, code entry version, does not extend
CFP702E-4K
CFP economy 2 zone panel, keyswitch version, does not extend
CFP704E-4
CFP economy 4 zone panel, code entry version, does not extend
CFP704E-4K
CFP economy 4 zone panel, keyswitch version, does not extend
CFP708E-4
CFP economy 8 zone panel, code entry version, does not extend
CFP708E-4K
CFP economy 8 zone panel, keyswitch version, does not extend
Manufactured by
C-TEC, Stephens Way, Wigan,
WN3 6PH. England
UK Sales:
Tel: 01942 322744. Fax: 01942 829867.
Email: sales@c-tec.co.uk
European Sales:
Tel: +44 1942 322744. Fax: +44 1942 829867.
Email: eu.exports@c-tec.co.uk
Export Sales:
Tel: +44 161 257 2541. Fax: +44 161 225 8817.
Email: xportsales@xportsales.com
Visit our website at www.c-tec.co.uk
CFP LPCB APPROVED EN54 FIRE PANELS
Include all CFP standard panel features except coincidence & non-latching zone facilities.
CFP702-4/LPC CFP 2 zone panel, LPCB approved to EN54-2/4,
does not extend, code entry
DISTRIBUTED BY
CFP704-4/LPC CFP 4 zone panel, LPCB approved to EN54-2/4,
does not extend, code entry
CFP708-4/LPC CFP 8 zone panel, LPCB approved to EN54-2/4,
does not extend, code entry
LPCB!Ref. 176a
to BS!EN 54 pts 2 &!4
Quality System Certificate No: 176
Assessed to ISO9001 : 2008
© Errors and omissions excepted.
C-TEC operates a policy of continuous improvement and we reserve the right to alter product specifications at our discretion and without prior notice. Approved Document No. DFS0380434 Rev 3
LPCB!Ref. 176a
to BS!EN 54 pts 2 &!4
CFP Technical Specifications
2-8 Zone EN54 Conventional Fire Alarm Panels
Power Supply Specification
range
Fully compliant with EN54 parts 2 and 4, the CFP conventional fire alarm panel offers an array of user and
installer friendly features.
Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4 and 8 zone versions are available, each
featuring four conventional sounder circuits, class change and alert inputs, two fire outputs, a fault output
and a reset output.
A wide range of engineering functions are also provided including (depending
on the model purchased) selectable zone delays, coincidence and non-latching
zone facilities. Comprehensive test and fault finding facilities are also provided
on all variants.
Mains supply voltage
Mains rated current
Internal power supply
Total output current limited to
Supply and battery charger monitored for failure
Batteries monitored for disconnection and failure
Batteries protected against deep discharge
Max. battery size and type
Mains fuse
Battery fuse
Current draw from battery (Mains failed)
230V 50/60Hz
350mA maximum
19V - 28.5V (27V nominal). Ripple 7V maximum (battery fault)
1.5A
YES (battery charger is also temperature compensated)
YES
YES (Deep discharge cut off approx. 21 volts)
2 x 12V 3.3AHr VRLA (Valve Regulated Lead Acid) connected in series
240V 1A HRC ceramic 20mm compliant with IEC (EN60127 PT2)
1.6A F 20mm compliant with IEC (EN60127 PT2)
1.5A maximum
Detector Circuit Specification
Number of circuits
Cable type
Connector blocks
Max cable length per circuit
Line monitored for open circuit and short circuit
Line monitored for detector removal
Maximum allowable impedance (each conductor)
Maximum cable capacitance
Call point resistor value
Max. number of smoke/heat detectors per zone
Max. combined number of detectors & manual call points
CFP Standard Panels
CFP Economy Panels
CFP LPCB Approved Panels
2 (CFP702-4 & CFP702-4K) 2 (CFP702E-4 & CFP702E-4K)
2 (CFP702-4/LPC)
4 (CFP704-4 & CFP704-4K) 4 (CFP704E-4 & CFP704E-4K)
4 (CFP704-4/LPC)
8 (CFP708-4 & CFP708-4K) 8 (CFP708E-4 & CFP708E-4K)
8 (CFP708-4/LPC)
Fire resistant screened cable, minimum conductor size 1mm2
Plug-on type, largest acceptable conductor size 1.5mm2
500 metres
YES
YES - end of line monitoring device modules provided
20W
0.27mF
470 to 680Ω
25
32 per zone
In addition to our standard and economy CFP panels, three LPCB
Sounder Circuit Specification
approved versions are available. The LPCB stamp of approval is
recognised worldwide and demonstrates that the CFP has been
tested and certified as being compliant with EN54 parts 2 and 4
by the Loss Prevention Certification Board.
Number of circuits
Cable type
Connector blocks
Max cable length per circuit
End of line resistor value
Each circuit monitored for open and short circuit
Alarm voltage
Sounder circuit fuses (one per circuit)
Maximum total sounder output current to all outputs
Maximum No. of bells @ 25mA
Maximum No. of electronic sounders @ 20mA
LPCB!Ref. 176a
to BS!EN 54 pts 2 &!4
4
Fire resistant screened cable, minimum conductor size 1mm2
Plug-on type, largest acceptable conductor size 1.5mm2
500 metres
6800 5% Tol. 0.25W (blue, grey, red, gold)
YES
27V maximum, 20V minimum (final battery voltage)
Resetable type (200mA min. hold current; 400mA max. trip current; 50mA when tripped. Reset when faults removed)
4 x 200mA = 800mA
32
40 (sounders must be polarised)
Auxiliary Outputs
! Fully compliant with EN54 Parts 2 and 4
!
Optional keyswitch or push button access code entry to
Access Levels 2 and 3
! Four conventional sounder circuits
!
Integral 1.5A switch mode PSU
! Standard, economy and LPCB approved
!
Detector and sounder circuits share common negative
allowing straightforward three-wire retro-installation
! Available with 2, 4 or 8 zone circuits
versions available
!
Installer-friendly design accommodates easy
first fix and straightforward maintenance
!
! Attractive flush or surface mountable plastic
lid and enclosure
!
Auxiliary remote, auxiliary fire, fault and
reset outputs
!
Ancillary connections provided for up to eight two-wire
repeaters (one CFP761 network driver card required per
system) and optional CFP relay boards. Ancillary
connections are not provided on CFP economy panels.
! End of line units included (one per zone)
Connect to OV to trigger. Max. input voltage 27V. (Non-latching)
Connect to OV to trigger. Max. input voltage 27V. (Non-latching)
User & Engineer Controls
General user controls (access level one)
Authorised user controls (access level two)
Engineer controls (access level three)
Mute internal sounder; Override delays; Enter access levels
Silence alarm sounders; Activate alarm sounders; Reset the system; Test the lamps; Disable/enable zones
Disable /enable fault output; Disable/enable remote output,Disable/enable sounders,
Disable/enable auxiliary output; Disable/enable output delays (not available on CFPE).
CFP Standard Panels
CFP Economy Panels
Program coincidence (double knock)
Invoke one man walk test
Setup zones for non-latching operation Enter fault diagnostic facilities
Program delays
Invoke one man walk test
Enter fault diagnostic facilities
CFP LPCB Approved Panels
Program delays
Invoke one man walk test
Enter fault diagnostic facilities
Indicators
ns on
y
tio si
l it
ec pan
ic
ity
l
t
ci
n
i
s
x
a
y
n e
c
f
ce ock
ng lit
fa
no
y
co
h i ci
la
y em
en n
st
ag s
tc fa
id le-k
ar st
te
de
di ie
ill s y
e
-la nes
e
lt ilit
nc ub
c
i
n
n
n
u
r
c
o
n
o
Zo
A fo
Zo
C (d
Fa fa
No zo
ty
il i
ac
)f
! Low quiescent current
! Multiple indicators
Non monitored open collector transistor
30mA each
27Vd.c
Active during reset cycle
Active during any unsilenced fire condition (provided all relevant delays have expired)
Active during any fire condition (provided all relevant delays have expired)
Active when no faults are present - failsafe to open circuit
Output protected by a resetable fuse (100mA min. hold current). Resets when fault removed
Auxiliary Inputs
Class Change (makes sounders sound continuously)
Alert (makes sounders pulse intermittently)
Wide range of engineering functions including (dependent
on model purchased) zone test, coincidence, zone delay
and non-latching zones. See chart below for details.
! ‘Class change’ and alert inputs
! Intuitive user-friendly interface
Type
Max. sink current
Max. open circuit voltage
Reset output
Remote output
Auxiliary output
Fault output
24V aux power output (for use with the above)
Which CFP?
CFP STANDARD PANELS
✔
✔
✔
✔
CFP ECONOMY PANELS
✗
✗
✔
✔
✗
CFP LPCB APPROVED PANELS
✔
✗
✗
✗
✔
✔
✔
✔
✔
This chart illustrates the different engineering functions available on the CFP range of fire panels
External indicators
General fire; Zone fire; Zone fault; Zone disabled; Zone test; Supply present;
Remote output activated; Remote output status; Test; Accessed; General disablement;
Fault output status; General fault; System fault; Repeater fault (not available on CFPE); System status;
Sounder status; Power supply fault; Auxiliary output status; Output delays (not available on CFPE).
Internal indicators
System fault (distinguishes between ‘watchdog’, ‘site memory’ and ‘phase lock loop’ faults);
Zone fault (distinguishes between open circuit and short circuit faults); Hazardous voltages present;
Repeater fault (indicates which repeaters, if fitted, are faulty - not available on CFPE)
Dimensions
Physical size
Weight
Size = 380 x 235 x 96mm approx.
1.75kg (without batteries)
CFP Technical Specifications
2-8 Zone EN54 Conventional Fire Alarm Panels
Power Supply Specification
range
Fully compliant with EN54 parts 2 and 4, the CFP conventional fire alarm panel offers an array of user and
installer friendly features.
Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4 and 8 zone versions are available, each
featuring four conventional sounder circuits, class change and alert inputs, two fire outputs, a fault output
and a reset output.
A wide range of engineering functions are also provided including (depending
on the model purchased) selectable zone delays, coincidence and non-latching
zone facilities. Comprehensive test and fault finding facilities are also provided
on all variants.
Mains supply voltage
Mains rated current
Internal power supply
Total output current limited to
Supply and battery charger monitored for failure
Batteries monitored for disconnection and failure
Batteries protected against deep discharge
Max. battery size and type
Mains fuse
Battery fuse
Current draw from battery (Mains failed)
230V 50/60Hz
350mA maximum
19V - 28.5V (27V nominal). Ripple 7V maximum (battery fault)
1.5A
YES (battery charger is also temperature compensated)
YES
YES (Deep discharge cut off approx. 21 volts)
2 x 12V 3.3AHr VRLA (Valve Regulated Lead Acid) connected in series
240V 1A HRC ceramic 20mm compliant with IEC (EN60127 PT2)
1.6A F 20mm compliant with IEC (EN60127 PT2)
1.5A maximum
Detector Circuit Specification
Number of circuits
Cable type
Connector blocks
Max cable length per circuit
Line monitored for open circuit and short circuit
Line monitored for detector removal
Maximum allowable impedance (each conductor)
Maximum cable capacitance
Call point resistor value
Max. number of smoke/heat detectors per zone
Max. combined number of detectors & manual call points
CFP Standard Panels
CFP Economy Panels
CFP LPCB Approved Panels
2 (CFP702-4 & CFP702-4K) 2 (CFP702E-4 & CFP702E-4K)
2 (CFP702-4/LPC)
4 (CFP704-4 & CFP704-4K) 4 (CFP704E-4 & CFP704E-4K)
4 (CFP704-4/LPC)
8 (CFP708-4 & CFP708-4K) 8 (CFP708E-4 & CFP708E-4K)
8 (CFP708-4/LPC)
Fire resistant screened cable, minimum conductor size 1mm2
Plug-on type, largest acceptable conductor size 1.5mm2
500 metres
YES
YES - end of line monitoring device modules provided
20W
0.27mF
470 to 680Ω
25
32 per zone
In addition to our standard and economy CFP panels, three LPCB
Sounder Circuit Specification
approved versions are available. The LPCB stamp of approval is
recognised worldwide and demonstrates that the CFP has been
tested and certified as being compliant with EN54 parts 2 and 4
by the Loss Prevention Certification Board.
Number of circuits
Cable type
Connector blocks
Max cable length per circuit
End of line resistor value
Each circuit monitored for open and short circuit
Alarm voltage
Sounder circuit fuses (one per circuit)
Maximum total sounder output current to all outputs
Maximum No. of bells @ 25mA
Maximum No. of electronic sounders @ 20mA
LPCB!Ref. 176a
to BS!EN 54 pts 2 &!4
4
Fire resistant screened cable, minimum conductor size 1mm2
Plug-on type, largest acceptable conductor size 1.5mm2
500 metres
6800 5% Tol. 0.25W (blue, grey, red, gold)
YES
27V maximum, 20V minimum (final battery voltage)
Resetable type (200mA min. hold current; 400mA max. trip current; 50mA when tripped. Reset when faults removed)
4 x 200mA = 800mA
32
40 (sounders must be polarised)
Auxiliary Outputs
! Fully compliant with EN54 Parts 2 and 4
!
Optional keyswitch or push button access code entry to
Access Levels 2 and 3
! Four conventional sounder circuits
!
Integral 1.5A switch mode PSU
! Standard, economy and LPCB approved
!
Detector and sounder circuits share common negative
allowing straightforward three-wire retro-installation
! Available with 2, 4 or 8 zone circuits
versions available
!
Installer-friendly design accommodates easy
first fix and straightforward maintenance
!
! Attractive flush or surface mountable plastic
lid and enclosure
!
Auxiliary remote, auxiliary fire, fault and
reset outputs
!
Ancillary connections provided for up to eight two-wire
repeaters (one CFP761 network driver card required per
system) and optional CFP relay boards. Ancillary
connections are not provided on CFP economy panels.
! End of line units included (one per zone)
Connect to OV to trigger. Max. input voltage 27V. (Non-latching)
Connect to OV to trigger. Max. input voltage 27V. (Non-latching)
User & Engineer Controls
General user controls (access level one)
Authorised user controls (access level two)
Engineer controls (access level three)
Mute internal sounder; Override delays; Enter access levels
Silence alarm sounders; Activate alarm sounders; Reset the system; Test the lamps; Disable/enable zones
Disable /enable fault output; Disable/enable remote output,Disable/enable sounders,
Disable/enable auxiliary output; Disable/enable output delays (not available on CFPE).
CFP Standard Panels
CFP Economy Panels
Program coincidence (double knock)
Invoke one man walk test
Setup zones for non-latching operation Enter fault diagnostic facilities
Program delays
Invoke one man walk test
Enter fault diagnostic facilities
CFP LPCB Approved Panels
Program delays
Invoke one man walk test
Enter fault diagnostic facilities
Indicators
ns on
y
tio si
l it
ec pan
ic
ity
l
t
ci
n
i
s
x
a
y
n e
c
f
ce ock
ng lit
fa
no
y
co
h i ci
la
y em
en n
st
ag s
tc fa
id le-k
ar st
te
de
di ie
ill s y
e
-la nes
e
lt ilit
nc ub
c
i
n
n
n
u
r
c
o
n
o
Zo
A fo
Zo
C (d
Fa fa
No zo
ty
il i
ac
)f
! Low quiescent current
! Multiple indicators
Non monitored open collector transistor
30mA each
27Vd.c
Active during reset cycle
Active during any unsilenced fire condition (provided all relevant delays have expired)
Active during any fire condition (provided all relevant delays have expired)
Active when no faults are present - failsafe to open circuit
Output protected by a resetable fuse (100mA min. hold current). Resets when fault removed
Auxiliary Inputs
Class Change (makes sounders sound continuously)
Alert (makes sounders pulse intermittently)
Wide range of engineering functions including (dependent
on model purchased) zone test, coincidence, zone delay
and non-latching zones. See chart below for details.
! ‘Class change’ and alert inputs
! Intuitive user-friendly interface
Type
Max. sink current
Max. open circuit voltage
Reset output
Remote output
Auxiliary output
Fault output
24V aux power output (for use with the above)
Which CFP?
CFP STANDARD PANELS
✔
✔
✔
✔
CFP ECONOMY PANELS
✗
✗
✔
✔
✗
CFP LPCB APPROVED PANELS
✔
✗
✗
✗
✔
✔
✔
✔
✔
This chart illustrates the different engineering functions available on the CFP range of fire panels
External indicators
General fire; Zone fire; Zone fault; Zone disabled; Zone test; Supply present;
Remote output activated; Remote output status; Test; Accessed; General disablement;
Fault output status; General fault; System fault; Repeater fault (not available on CFPE); System status;
Sounder status; Power supply fault; Auxiliary output status; Output delays (not available on CFPE).
Internal indicators
System fault (distinguishes between ‘watchdog’, ‘site memory’ and ‘phase lock loop’ faults);
Zone fault (distinguishes between open circuit and short circuit faults); Hazardous voltages present;
Repeater fault (indicates which repeaters, if fitted, are faulty - not available on CFPE)
Dimensions
Physical size
Weight
Size = 380 x 235 x 96mm approx.
1.75kg (without batteries)
TYPICAL WIRING
TYPICAL DETECTOR
CIRCUIT WIRING
TYPICAL SOUNDER
CIRCUIT WIRING
TYPICAL AUX.
OUTPUT WIRING
TYPICAL AUX.
INPUT WIRING
END OF LINE
RESISTOR
(6k8 Ohm)
END OF LINE
CAPACITOR
Relay
Activated
AUXILIARY
FIRE RELAY
SMOKE OR HEAT
DETECTOR
ALERT INPUT
POLARISED
SOUNDER
Relay
Activated
AUXILIARY
FIRE RELAY
range
MANUAL
CALL POINT
POLARISED
SOUNDER
DO NOT SPUR
(wiring not monitored)
SMOKE OR HEAT
DETECTOR
Relay
Activated
AUXILIARY
FIRE RELAY
CLASS CHANGE
INPUT
DO NOT SPUR
(wiring not monitored)
Relay
Activated
POLARISED
SOUNDER
AUXILIARY
FIRE RELAY
GUIDANCE DIAGRAM ONLY
MORE DETAILED WIRING INFORMATION
AVAILABLE ON REQUEST
MANUAL
CALL POINT
Unused detector circuits
should be terminated
with an end of line resistor
Unused detector circuits should be
terminated with an end of line capacitor
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
DETECTOR CIRCUITS
SC1
SC2
SC3
SC4
SOUNDER CIRCUITS
AUX
AUX RESET 24V
REM FAULT
OUTPUTS
0V
ALERT
CC
INPUTS
CFP STANDARD EN54 FIRE PANELS & ANCILLARIES
CFP702-4
CFP standard 2 zone panel, code entry version, does not extend
CFP702-4K
CFP standard 2 zone panel, keyswitch version, does not extend
CFP704-4
CFP standard 4 zone panel, code entry version, does not extend
CFP704-4K
CFP standard 4 zone panel, keyswitch version, does not extend
CFP708-4
CFP standard 8 zone panel, code entry version, does not extend
CFP708-4K
CFP standard 8 zone panel, keyswitch version, does not extend
CFP760
CFP 8 zone repeater panel, up to 8 per system, code entry version
CFP760K
CFP 8 zone repeater panel, up to 8 per system, keyswitch version
CFP761
CFP network driver card (one required per repeater system, fit at main)
CFP762
CFP relay output card (provides reset, fault, aux & remote relay outputs)
CFP763
CFP relay output per zone card (as CFP762 plus 8 output per zone relays)
CFP ECONOMY EN54 FIRE PANELS
Include all CFP standard panel features except coincidence, zone delay and non-latching zone
facilities. CFP economy panels are not compatible with CFP repeaters or CFP relay output cards
CFP702E-4
CFP economy 2 zone panel, code entry version, does not extend
CFP702E-4K
CFP economy 2 zone panel, keyswitch version, does not extend
CFP704E-4
CFP economy 4 zone panel, code entry version, does not extend
CFP704E-4K
CFP economy 4 zone panel, keyswitch version, does not extend
CFP708E-4
CFP economy 8 zone panel, code entry version, does not extend
CFP708E-4K
CFP economy 8 zone panel, keyswitch version, does not extend
Manufactured by
C-TEC, Stephens Way, Wigan,
WN3 6PH. England
UK Sales:
Tel: 01942 322744. Fax: 01942 829867.
Email: sales@c-tec.co.uk
European Sales:
Tel: +44 1942 322744. Fax: +44 1942 829867.
Email: eu.exports@c-tec.co.uk
Export Sales:
Tel: +44 161 257 2541. Fax: +44 161 225 8817.
Email: xportsales@xportsales.com
Visit our website at www.c-tec.co.uk
CFP LPCB APPROVED EN54 FIRE PANELS
Include all CFP standard panel features except coincidence & non-latching zone facilities.
CFP702-4/LPC CFP 2 zone panel, LPCB approved to EN54-2/4,
does not extend, code entry
DISTRIBUTED BY
CFP704-4/LPC CFP 4 zone panel, LPCB approved to EN54-2/4,
does not extend, code entry
CFP708-4/LPC CFP 8 zone panel, LPCB approved to EN54-2/4,
does not extend, code entry
LPCB!Ref. 176a
to BS!EN 54 pts 2 &!4
Quality System Certificate No: 176
Assessed to ISO9001 : 2008
© Errors and omissions excepted.
C-TEC operates a policy of continuous improvement and we reserve the right to alter product specifications at our discretion and without prior notice. Approved Document No. DFS0380434 Rev 3
LPCB!Ref. 176a
to BS!EN 54 pts 2 &!4