NIVUS Pipe Mounting System RMS Instruction
Nivus Pipe Mounting System RMS is designed for temporary sensor installation in pipes, primarily for portable flow measurements. It's compatible with various NIVUS wedge and air-ultrasonic sensors (CS2, CSM, KDA, POA, DSM, OCL) across a range of pipe diameters (DN200 - DN2000), utilizing a robust stainless steel (1.4404) construction. Multiple system configurations (RMS 2, 3, 4, 5) cater to different pipe sizes and sensor combinations.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
31
Installation Instruction for Pipe Mounting Systems RMS Rev. 00 / 21.04.2017 (Original Manual: German) Branches NIVUS AG NIVUS Sp. z o.o. Burgstraße 28 CH - 8750 Glarus Tel.: +41 (0)55 6452066 Fax: +41 (0)55 6452014 E-mail: [email protected] Internet: www.nivus.de ul. Hutnicza 3 / B-18 PL - 81-212 Gdynia Tel.: +48 (0) 58 7602015 Fax: +48 (0) 58 7602014 E-mail: [email protected] Internet: www.nivus.pl NIVUS Austria NIVUS Middle East (FZE) Mühlbergstraße 33B A-3382 Loosdorf Tel.: +43 (2754) 567 63 21 Fax: +43 (2754) 567 63 20 E-mail: [email protected] Internet: www.nivus.de Building Q 1-1 ap. 055 P.O. Box: 9217 Sharjah Airport International Free Zone Tel.: +971 6 55 78 224 Fax: +971 6 55 78 225 E-mail: [email protected] Internet: www.nivus.com NIVUS France 14, rue de la Paix F - 67770 Sessenheim Tel.: +33 (0)3 88071696 Fax: +33 (0)3 88071697 E-mail: [email protected] Internet: www.nivus.fr NIVUS U.K. Ltd Head office UK: Wedgewood Rugby Road Weston under Wetherley Royal Leamington Spa CV33 9BW, Warwickshire Tel.: +44 (0)8445 3328 83 E-mail: [email protected] Internet: www.nivus.com page 2 NIVUS Korea Co. Ltd. #2502, M Dong, Technopark IT Center, 32 Song-do-gwa-hak-ro, Yeon-su-gu, INCHEON, Korea 406-840 Tel. +82 32 209 8588 Fax. +82 32 209 8590 E-Mail: [email protected] Internet: www.nivus.com NIVUS Vietnam 21 Pho Duc Chinh, Ba Dinh, Hanoi, Vietnam Mobile (VN) 012 0446 7724 [email protected] Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems Copyrights and property rights This document and its contents are proprietary to NIVUS GmbH and are not to be reproduced or copied without the express written permission of NIVUS GmbH. Violations oblige to compensation. Important Note This manual may exclusively - even in parts - be copied or translated in any other way with the express written consent of NIVUS GmbH. Translation If the device is sold to a country in the European Economic Area (EEA) this manual must be translated into the language of the country in which the device is to be used. Should the translated text be unclear, the original manual (German) must be consulted or the manufacturer contacted for clarification. Copyright No part of this publication may be reproduced, transmitted, sold or disclosed without prior permission. Damages will be claimed for violations. All rights reserved. Names The use of general descriptive names, trade names, trade-marks and the like in this manual does not entitle the reader to assume they may be used freely by everyone. They are often protected registered trademarks even if not marked as such. Pipe mounting systems / Rev. 00 / 21.04.2017 page 3 Table of contents Table of contents Copyrights and property rights 3 Table of contents 4 General 5 1 Applicable documentation ....................................................................... 5 2 Required Tools/Utilities ........................................................................... 5 3 Signs and definitions used ...................................................................... 6 3.1 Abbreviations used ..................................................................... 6 Safety Instructions 4 Used symbols and signal words ............................................................. 7 4.1 Protective conductor................................................................... 8 5 Use in accordance with the requirements ............................................... 8 5.1 User’s Responsibilities ............................................................... 9 5.1.1 5.1.2 Manual Keeping ................................................................................... 9 Manual Handover................................................................................. 9 5.2 Liability Disclaimer...................................................................... 9 Product specification 6 7 10 Overview Pipe Mounting Systems ........................................................10 6.1 Overview Pipe Mounting System RMS 2 .................................11 6.2 Overview Pipe Mounting System RMS 3 .................................12 6.3 Overview Pipe Mounting System RMS 4 .................................13 6.4 Overview Pipe Mounting System RMS 5 .................................14 Assembly 16 Assembly of the Pipe Mounting Systems..............................................16 7.1 Principles of Installation ...........................................................16 7.2 Principles of Sensor Fastening ................................................17 7.3 Assembly of pipe mounting system RMS 2 .............................18 7.4 Assembly of pipe mounting system RMS 3 .............................20 7.5 Assembly of pipe mounting system RMS 4 .............................23 7.6 Assembly of pipe mounting system RMS 5 .............................24 7.6.1 7.6.2 7.6.3 Base plate RMS 5 .............................................................................. 24 Extension sheet RMS 5 ..................................................................... 26 Assembling the clamping device ........................................................ 27 7.7 Air-Ultrasonic sensors in the RMS 5 pipe mounting system ....28 Maintenance page 4 7 31 8 Maintenance ..........................................................................................31 8.1 Spare parts and accessories ....................................................31 9 Dismantling/Disposal.............................................................................31 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems General Important Note READ CAREFULLY BEFORE USE! KEEP IN A SAFE PLACE FOR LATER REFERENCE. This manual is an original instruction for the pipe mounting systems RMS and is for the intended use of the device. This manual is oriented exclusively to qualified expert personnel. Read this manual carefully and completely prior to installation and connection since it contains relevant information on this product. Observe the notes and particularly follow the warning notes and safety instructions. If you should have problems to understand information contained within this manual either contact the manufacturer or one of the distributors for further support. The manufacturer cannot be held responsible for damage to persons or material due to incorrectly understood information in this instruction. 1 Applicable documentation For the installation and operation of the complete system extra instruction manuals or technical descriptions may be required apart from this manual. Installation Instruction for Correlation and Doppler Sensors Technical Instructions for Correlation Sensors and external Electronic Box Technical Instruction for Doppler Sensors These manuals are provided with the sensors. 2 Required Tools/Utilities The following tools/utilities are required to install the pipe mounting systems hammer (300 g) cable ties ring or open-end spanner, spanner gap 13 (for RMS 2) Phillips screw driver Pozidriv size 2 wire cutter RMS 5 only The following tools are required to modify the air-ultrasonic sensors: ring or open-end spanner, spanner gap 22 Phillips screw driver Phillips size 1 The tools are not part of the standard delivery. Pipe mounting systems / Rev. 00 / 21.04.2017 page 5 General 3 Signs and definitions used Image Meaning Remark (Action) Step Action to be performed by you Note the numbering of action steps. Observe the order of the working steps! 3.1 Cross-reference Reference to further or detailed information >Text< Parameter or Menu Indicates selected or described parameters or menus Reference to document Refers to an accompanying documentation Abbreviations used Item designation page 6 CS2 CSM Cross correlation sensors of the Mini sensor family DSM Air-Ultrasonic sensor of the Mini sensor family KDA Doppler sensor OCL Air-Ultrasonic sensor POA Cross correlation sensors for use in part filled and full pipes and open channels RMS Pipe mounting system Cross correlation sensors for use in part filled and full pipes and open channels Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems Safety Instructions 4 Used symbols and signal words The general warning symbol indicates the risk of personal injuries or death. In the text section the general warning symbol is used in conjunction with the signal words described below. WARNING Warnings at medium level risk and risk of personal injury Indicates a possible danger with medium risk which may result in a life-threatening situation or (severe) personal injury if not avoided. CAUTION Warnings at low level risk or property damages Indicates a possible danger with moderate risk which may result in minor or moderate personal injury or material damage if not avoided. Important Note Contains information that should be highlighted. Indicates a potentially damaging situation which can result in a damage of the product or an object in its environment if not avoided. Note Contains information and facts. Pipe mounting systems / Rev. 00 / 21.04.2017 page 7 Safety Instructions 4.1 Protective conductor WARNING Germ contamination Please note that due to the operation in the waste water field the measurement system and cables may be loaded with dangerous disease germs. Respective precautionary measures must be taken to avoid damage to one’s health. Wear protective clothing. WARNING Observe occupational safety regulations Before starting installation work, check whether the occupational safety regulations are observed. Disregarding may lead in personal injury. CAUTION Risk of injury The pipe mounting system sheets have very sharp edges. There is a risk of injury from cuts. Wear protective gloves. 5 Use in accordance with the requirements Important note The pipe mounting systems and all corresponding components are intended solely for the purpose described below. The pipe mounting systems are designed for the temporary installation of sensors in pipes. Modifying or using the instruments for any other purposes without the manufacturer’s written consent will not be considered as use in accordance with the requirements. The manufacturer cannot be held responsible for any damage resulting from improper use. The user alone bears any risk. page 8 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems 5.1 User’s Responsibilities Important Note In the EEA (European Economic Area) national implementation of the frame-work directive 89/391/EEC and corresponding individual directives, in particular the directive 2009/104/EC concerning the minimum safety and health requirements for the use of work equipment by workers at work, as amended, are to be observed and adhered to. In Germany the Industrial Safety Ordinance must be observed. 5.1.1 Manual Keeping Keep this manual in a safe place and make sure it is available for the user of this product at any time. 5.1.2 Manual Handover In case of selling the instruments this manual shall be provided to the purchaser since it is a part of the standard delivery. 5.2 Liability Disclaimer The manufacturer reserves the right to change the contents of this document including this liability disclaimer without prior notice and cannot be held responsible in any way for possible consequences resulting from such changes. For installation of the pipe mounting systems the following information and higher legal regulations of the respective country (e. g. VDE regulations in Germany) such as applicable safety requirements and regulations in order to avoid accidents shall be observed. All operations on the instruments which go beyond installation shall be carried out by NIVUS staff or personnel authorised by NIVUS due to reasons of safety and guarantee. The manufacturer is not responsible for failures resulting from improper use. Pipe mounting systems / Rev. 00 / 21.04.2017 page 9 Product specification Product specification This installation manual exclusively refers to the installation of pipe mounting systems in pipelines. The pipe mounting systems are mainly used for portable flow measurements. All pipe mounting systems are made of stainless steel 1.4404. The pipe mounting systems are installation aids for the following wedge sensors: CS2 CSM KDA POA Air-ultrasonic sensors below can be installed too: DSM OCL The technical data of the sensors are listed in the corresponding manuals. 6 Overview Pipe Mounting Systems Four different sets are available: RMS 2 – Pipe mounting set for pipes DN200 to DN800 RMS 3 – Pipe mounting set for pipes DN150 to DN300 RMS 4 – Combination of RMS 2 and RMS 3. Pipe mounting set for pipes DN150 to DN800 RMS 5 – Pipe mounting set for pipes DN700 to DN2000 Pipe mounting sets consist of the following elements: Clamping device Base plate Clamps Extension sheets Completion plate (optional) The individual parts of the RMS 2, RMS 3 and RMS 4 pipe mounting systems are compatible with each other. The RMS 5 system uses thicker materials and hence cannot be combined with components of other sets. Details on the scope of delivery can be found in the according overview of the individual mounting sets. page 10 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems 6.1 Overview Pipe Mounting System RMS 2 Scope of Delivery set RMS 2: 1x Carrying bag, blue 1x Base plate 1x Clamping device with rotary toggle 2x Extension sheet V5 2x Extension sheet V10 2x Extension sheet V15 8x Clamp 1 2 3 4 5 6 Clamp Extension sheet V5 Extension sheet V10 Base plate Extension sheet V15 Clamping device with rotary toggle Fig. 6-1 Parts of RMS 2 Fig. 6-2 Completion plates (optional) of RMS 2 and RMS 3 Pipe mounting systems / Rev. 00 / 21.04.2017 page 11 Product specification Insideø [mm] BST Base plate SPV Clamping device 200 1 Hole outside 1 250 1 Hole inside 1 2 300 1 Hole outside 1 2 350 1 Hole inside 1 2 400 1 Hole outside 1 2 450 1 Hole inside 1 2 2 500 1 Hole outside 1 2 2 600 1 Hole outside 1 2 700 1 Hole outside 1 800 1 Hole outside 1 Fig. 6-3 6.2 V5 Extension sheet V10 Extension sheet 2 V15 Extension sheet 2 2 2 2 2 List of required plates and sheets RMS 2 Overview Pipe Mounting System RMS 3 Scope of Delivery set RMS 3: 1x Carrying bag, blue 1x Base plate 1x Clamping device 1x Extension sheet V5 1x Extension sheet V10 4x Clamp 1 2 3 4 5 Clamp Base plate BST Extension sheet V5 Extension sheet V10 Clamping device Fig. 6-4 page 12 Parts of RMS 3 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems Inside-ø [mm] BST Base plate SPV Clamping device V5 Extension sheet 150 1 Hole inside 1 1 200 1 Hole inside 1 250 1 Hole inside 1 1 1 300 1 Hole outside 1 1 1 Fig. 6-5 6.3 V10 Extension sheet 1 List of required plates RMS 3 Overview Pipe Mounting System RMS 4 The pipe mounting system RMS 4 is combined out of RMS 2 and RMS 3. See tables in Fig. 6-3 and Fig. 6-5. Scope of Delivery set RMS 4: 1x Carrying bag, blue 1x Base plate RMS 2 1x Base plate RMS 3 1x Clamping device RMS 2 1x Clamping device RMS 3 2x Extension sheet V5 2x Extension sheet V10 2x Extension sheet V15 Pipe mounting systems / Rev. 00 / 21.04.2017 page 13 Product specification 6.4 Overview Pipe Mounting System RMS 5 Scope of Delivery set RMS 5: 1x Carrying bag, blue 1x Base plate 1x Clamping device 4x Extension sheet VS 4x Extension sheet VM 4x Extension sheet VL 10x Clamp 1x Distance plate for DSM-L0 (two parts) 1x Distance plate for OCL-L1 1 2 3 4 5 6 7 8 Clamping device Distance plate for OCL-L1 Distance plate for DSM-L0 (two parts) Base plate BST Extension sheet VS Extension sheet VM Extension sheet VL Clamp Fig. 6-6 page 14 Parts of RMS 5 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems Number of plates Inside-ø [mm] Base plate 700 1 Without Air-Ultrasonic sensor short middle long (VS) (VM) (VL) 4 800 1 2 3 1 900 1 2 2 2 2 1000 1 4 2 1 3 1100 1 4 3 3 1200 1 2 4 2 4 1300 1 2 2 2 1400 1 4 2 1 1 2 1500 1 2 2 3 1 2 1600 1 2 2 2 2 2 2 1700 1 4 2 2 3 3 2 1800 1 4 2 3 3 2 1900 1 2 4 2 2 4 2 2000 1 2 4 2 Fig. 6-7 With Air-Ultrasonic sensor short middle long (VS) (VM) (VL) 1 1 2 4 List of required plates RMS 5 Pipe mounting systems / Rev. 00 / 21.04.2017 page 15 Assembly Assembly 7 Assembly of the Pipe Mounting Systems WARNING Check hazards caused by explosive gases! Prior to executing mounting works in sewer systems always check compliance with all regulations on safety at work. Check possible hazards caused by explosive gases by using a gas detector. Disregarding may lead to personal injury. CAUTION Risk of injury The pipe mounting system sheets have very sharp edges. There is a risk of injury from cuts. Wear protective gloves. Note In larger pipe diameters it may be necessary to additionally secure the pipe mounting system from being washed away due to high flow velocities. Use stainless steel screws for this purpose. 7.1 Principles of Installation The number of sheets depends on the existing inner pipe diameter. The mounting steps for the individual pipe mounting systems are described in chapter >Mounting<. The following applies for the mounting of pipe mounting systems: page 16 Observe the selection list of mounting sheets. Place the clamping device always in the pipe crown (except when using an airultrasonic sensor). Place the base plate on the pipe bottom. Install the same number of required extension plates left and right between clamping device and base plate (except when using an air-ultrasonic sensor). Install plates parallel to the pipe walls. Insert clamps towards the flow direction flush with the mounting plates. Observe appropriate contact pressure on the pipe walls to prevent the mounting system from getting loose. In larger channel diameters it may be necessary to additionally fix the pipe mounting system on the channel walls by using stainless steel screws. No gap shall remain between mounting plate and sensor as well as between base plate and channel bottom (risk of build-up). Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems 7.2 Principles of Sensor Fastening The following applies for using air-ultrasonic sensor and wedge sensor at the same time: Place air-ultrasonic sensor on pipe crown. Align air-ultrasonic sensor plane parallel to water surface. Install clamping device immediately adjacent to air-ultrasonic sensor. Use completion plate (optional for RMS 2-4) for wedge sensor (Fig. 6-2). Fig. 7-1 Basic sensor fastening With heavy dirt load or sedimentation: Place wedge sensor off centre (towards step irons). Lay the sensor cable to the same side as the sensor. Do not lay cables across channel bottom. Fix sensor cables to RMS using cable ties and lay upwards. 1 2 3 4 5 6 Pipe wall Pipe mounting system Sedimentation Sensor Cable Cable tie Fig. 7-2 Install sensor off centre Pipe mounting systems / Rev. 00 / 21.04.2017 page 17 Assembly 7.3 Assembly of pipe mounting system RMS 2 Measure the pipe diameter before you begin installation. The table in Fig. 6-3 shows which sheets to use for which pipe diameter. Put the RMS components on a plane surface. Assemble base plate and extension plate. Insert the spigots of the base plate into the holes of the extension sheet. Insert the clamp towards the flow direction flush with the mounting plate. If the clamp cannot be fastened easily use a hammer to carefully hammer the clamp into position. page 18 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems Place flow velocity sensor Put the flow velocity sensor onto the base plate with the slotted holes down. Pull sensor backwards on the base plate. Sensor shall be arrested flush with the base plate. Assemble RMS completely When the inner pipe diameter is reached: Assemble clamping device and extension sheet. Insert the spigots of the clamping device into the holes of the extension sheet. Fasten clamping device to extension sheets on both sides using clamps. Prior to installation in the channel fully close the clamping device by rotating clockwise. Pipe mounting systems / Rev. 00 / 21.04.2017 page 19 Assembly Insert the complete pipe mounting system into the pipe and align accordingly. Open the clamping device by rotating counterclockwise until the pipe mounting system is clamped firmly within the pipe. Note Always fix the cable to the RMS (small holes) by using cable ties. Do not lay the sensor cable across the invert centre. Fig. 7-3 7.4 RMS 2 with mounted POA and air-ultrasonic sensor Assembly of pipe mounting system RMS 3 Proceed as described under RMS 2. 1. Measure the pipe diameter. 2. Select the required plates from the set (see table in Fig. 6-5). 3. Put the components on a plane surface. 4. Assemble base plate and extension sheets as seen with RMS 2. page 20 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems Insert Mini Sensor family flow velocity sensor CSM: Put the CSM flow velocity sensor with the slotted holes down onto the base plate. Pull sensor backwards on the base plate until arrested. Important: The cable side of the sensor is not flush with the base plate. CSM-D: Put the CSM-D flow velocity sensor with the slotted holes down onto the base plate. Pull sensor backwards on the base plate until arrested. Pipe mounting systems / Rev. 00 / 21.04.2017 page 21 Assembly Flow velocity sensor and air-ultrasonic sensor CSM-D on completion plate: Put the flow velocity sensor with the slotted holes down onto the completion plate. Pull sensor backwards on the completion plate until arrested. Put the DSM air-ultrasonic sensor alongside the extension sheet. Push extension sheet through the slot between sensor mounting plate and cover plate. Slot see Fig. 7-10. page 22 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems RMS 3 pipe mounting system with completion plate for common installation of wedge sensor and air-ultrasonic sensor. The clamping device is placed laterally to the air-ultrasonic sensor. 7.5 Assembly of pipe mounting system RMS 4 The RMS 4 is a combination of RMS 2 and RMS 3. The selection of base plate and clamping device depends on the sensor used. Extension sheets are determined based on the pipe diameter. For installation proceed as described under RMS 2 and RMS 3. Pipe mounting systems / Rev. 00 / 21.04.2017 page 23 Assembly 7.6 Assembly of pipe mounting system RMS 5 Note Since the dimensions of the RMS 5 complicate the handling of the individual components NIVUS recommends 2 persons to assemble and to install the RMS 5. The RMS 5 pipe mounting system is designed for large inner pipe diameters. This is why the sheets are much larger than those of the other pipe mounting systems. 7.6.1 Firstly equip the base plate with sensors and wedge supports if required. Do not assemble the RMS 5 completely before you are on site. Base plate RMS 5 Several mounting aids can be found on the base plate. 1 2 3 4 5 6 Fastening holes for extension sheets Fastening holes for outer sensors or wedge supports Specification of nominal diameter according to Gauss. Positioning aid for three flow velocity sensors Fastening for centre flow velocity sensor sensor Indication of flow direction Optional / additional fastening with cable ties Fig. 7-4 page 24 Mounting aids on the RMS 5 base plate Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems Place sensors on the base plate Up to 3 flow velocity sensors can be fixed on the base plate. The centre flow velocity sensor shall be installed so that the slotted holes lock into the spigots on the base plate. Here the sensor tip must face the arrow on the base plate (Fig. 7-4, point 5). When using the flow velocity sensors below observe to use both rear slotted holes for locking: CS2 KDA POA The position of both outer sensors depends on the inner pipe diameter and is based on the Gauss specifications. The according sensor positions are marked on the base plate specifying a DN figure. Mount outer sensors horizontally To mount both outer flow velocity sensors horizontally two wedge supports (30°) must be installed first. The wedge supports are available from NIVUS. See accessories on page 31. The wedge supports shall be fastened at the according positions (DN markings) on the base plate by using the accompanying countersunk head screws. Then fix the sensor on the wedge support by using the accompanying countersunk head screws. RMS 5 with three sensors. For horizontal mounting: Mount both outer sensors on wedge supports (30°). Pipe mounting systems / Rev. 00 / 21.04.2017 page 25 Assembly Fig. 7-5 7.6.2 RMS 5 mounted horizontally (before installation) Extension sheet RMS 5 Insert the spigots of the RMS 5 extension sheet into the holes of the base plate and fix the sheet with a clamp. Use the front pairs of holes to assemble extension sheets and base plate if an airultrasonic sensor is to be installed at the pipe crown. 1 2 Fastening of extension sheets using an air-ultrasonic sensor Fastening of extension sheets using flow velocity sensors only Fig. 7-6 page 26 Fastening the extension sheets Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems 7.6.3 Assembling the clamping device Proceed as described in the RMS 2 mounting instructions. 1. Assemble clamping device and extension sheet. 2. Insert the spigots of the clamping device into the holes of the extension sheet. 3. Fix the clamping device at the extension sheets on both sides by using clamps. Fig. 7-7 Clamping device fully assembled Pipe mounting systems / Rev. 00 / 21.04.2017 page 27 Assembly 7.7 Air-Ultrasonic sensors in the RMS 5 pipe mounting system The type OCL and DSM air-ultrasonic sensors are conceived for temporary clamped fastening in a pipe mounting system. As per default both air-ultrasonic sensors feature slots to slide the RMS sheets through. The installation of air-ultrasonic sensors is described on page 23. Fig. 7-8 Pre-installed air-ultrasonic sensor on RMS sheet Exception: Air-ultrasonic sensors in RMS 5. Here the slot needs to be enlarged. Air-Ultrasonic sensor in RMS 5 Note Type OCL or DSM air-ultrasonic sensors must be modified to be used with a RMS 5 pipe mounting system. The RMS 5 pipe mounting system is conceived for larger pipe diameters. This is why the individual sheets and plates are designed with extra material thickness. Due to this the slots of the air-ultrasonic sensor types OCL and DSM need to be larger. The distance plates for the according air-ultrasonic sensor are part of the standard delivery of the RMS 5. RMS 5 standard delivery see Fig. 6-6. Modification of Air-Ultrasonic sensor To modify a type OCL air-ultrasonic sensor proceed as follows: 1. Loosen screws of the cover plate (2) with Phillips screwdriver Phillips size 1. 2. Remove cover plate. 3. Screw on the OCL-L1 distance plate. page 28 Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems 1 2 3 Mounting plate Cover plate Slot for pipe mounting system Fig. 7-9 Mounting plates of type OCL air-ultrasonic sensor To modify a type DSM air-ultrasonic sensor proceed as follows: 1. Loosen screws of the cover plate (5) with Phillips screwdriver Phillips size 1. 2. Remove cover plate and both distance plates (3). 3. Replace distance plates with DSM distance plates from RMS 5. 4. Screw on distance plates together with cover plate. 1 2 3 4 5 Mounting plate Extra plate Distance plate (two parts) short and long Slot for pipe mounting system Cover plate Fig. 7-10 Mounting plates of type DSM air-ultrasonic sensor Pipe mounting systems / Rev. 00 / 21.04.2017 page 29 Assembly Clamping sheets installed with CS2 sensors Clamping device installed with airultrasonic sensor Fig. 7-11 page 30 Mounting plates and sheets fully installed with sensors Pipe mounting systems / Rev. 00 /21.04.2017 Installation instruction Pipe Mounting Systems Maintenance 8 Maintenance WARNING Germ contamination Please note that due to the operation in the waste water field the measurement system and cables may be loaded with dangerous disease germs. Respective precautionary measures must be taken to avoid damage to one’s health. Wear protective clothing. The pipe mounting systems are made of stainless steel and thus virtually maintenancefree. 8.1 Spare parts and accessories Wedge supports 30° ZUB0 KS00 L30V4A Wedge supports 30° Wedge support left 30° for POA and CS2 sensor; for horizontal sensor installation in pipes. Material: stainless steel 1.457 ZUB0 KS00 R30V4A Wedge support right 30° for POA and CS2 sensor; for horizontal sensor installation in pipes. Material: stainless steel 1.457 Distance plate DSM Extra distance plate to enlarge the RMS 5 slot Distance plate OCL Extra distance plate to enlarge the RMS 5 slot Base plate RMS 2 Spare part for pipe mounting system RMS 2 ZUB0 RMS2 BSB Base plate RMS 3 Spare part for pipe mounting system RMS 3 ZUB0 RMS3 BSB Base plate RMS 5 Spare part for pipe mounting system RMS 5 ZUB0 RMS5 BSB Completion plate ZUB0 RMS2 EB RMS 2 completion plate for parallel installation of POA, CS2 and KDA wedge sensors and air-ultrasonic sensors, suitable for pipelines starting at DN250 The accessories are optionally available. More accessories for our pipe mounting systems can be found in our current price list. 9 Dismantling/Disposal Remove sensors from base plate. Remove wedge supports from the RMS 5 base plate. The stainless steel sheets and plates of the pipe mounting systems can be recycled as regular scrap metal. Pipe mounting systems / Rev. 00 / 21.04.2017 page 31
advertisement
Key Features
- Versatile pipe diameter compatibility
- Stainless steel construction
- Modular design for various sensors
- Portable flow measurement solutions
Frequently Answers and Questions
What tools are needed to install the RMS 2?
A 300g hammer, cable ties, a 13mm ring or open-end spanner, a Pozidriv size 2 Phillips screwdriver, and wire cutters are required.
What sensors are compatible with the RMS systems?
The systems are compatible with CS2, CSM, KDA, POA, DSM, and OCL sensors.
Can RMS components be interchanged between different RMS sets?
RMS 2, 3, and 4 components are compatible; however, RMS 5 uses thicker materials and is not compatible with other sets.
What is the material of the pipe mounting systems?
All pipe mounting systems are made of stainless steel 1.4404.
How should I handle the RMS 5 assembly?
Due to the size of RMS 5 components, NIVUS recommends two people for assembly and installation.