Corrective action when MELSOFT products cannot be installed on a

Corrective action when MELSOFT products cannot be installed on a
TECHNICAL BULLETIN
[1/5]
[Issue No.] FA-A-0210
[Title] Corrective action when MELSOFT products cannot be installed on a personal computer on
which the 6th Generation Intel Core Processor has been installed
[Date of Issue] June 2016
[Relevant Models] MELSOFT series
Thank you for your continued support of Mitsubishi FA software MELSOFT series.
This bulletin explains the symptom that MELSOFT products cannot be installed on a personal computer on
which the 6th Generation Intel® Core™ Processor has been installed, and its corrective action.
1.
SYMPTOM
(1) The installation does not start.
The following screen that indicates the start of installation does not appear at the start of the installation.
(2) The installation stops during the installation.
The installation stops if the specific product is selected for installation during the installation.
TECHNICAL BULLETIN
[2/5]
[Issue No.] FA-A-0210
2.
CONDITIONS
2.1 Specification of a Personal Computer
The symptom occurs when the BIOS*1 or UEFI*2 has any problem (chapter 3) on a personal computer that
meets following conditions:
• The 6th Generation Intel Core Processor is installed.
• The personal computer outputs videos using an on-board video (built into CPU).
• Microsoft® Windows® 7 32-bit edition is used.
*1
*2
2.2
Short for Basic Input/Output System.
The BIOS is located on the motherboard and it manages and controls peripheral devices connected to the personal computer.
Short for Unified Extensible Firmware Interface. UEFI replaces the BIOS.
Occurrence Situation in MELSOFT Products
Product name
Situation
iQ Works
The symptom occurs during installation in the following situation:
• Installation of GX Developer included in the product is selected on the installation screen.
The symptom does not occur in the products such as update version and trial version since
GX Developer is not included in these products.
GX Works3
The symptom occurs during installation in any of the following situations:
• Installation of GX Developer included in the product is selected on the installation screen by
following the installation procedure.
• The setup.exe of GX Developer included in the product is executed.
The symptom does not occur in the products such as update version and trial version since
GX Developer is not included in these products.
GX Works2
Ver. 1.519R or
later
The symptom occurs during installation in the following situation:
• The setup.exe of GX Developer included in the product is executed.
The symptom does not occur in the products such as update version and trial version since
GX Developer is not included in these products.
Ver. 1.513K or
earlier
The symptom occurs during installation in any of the following situations:
• Installation of GX Developer included in the product is selected on the installation screen by
following the installation procedure.
• The setup.exe of GX Developer included in the product is executed.
• The setup.exe of Configurator-QP included in the product is executed.
The symptom does not occur in the products such as update version and trial version since
GX Developer and Configurator-QP are not included in these products.
GT Works3
The symptom occurs in any of the following situations:
• The setup.exe of MES DB Connection Service (for GT Works3) included in the product is
executed.
• The setup.exe of the multimedia data link tool (for GT Works3) included in the product is
executed.
MT Works2
The symptom does not occur.
RT ToolBox2 / RT ToolBox2 mini
The symptom does not occur.
MR Configurator2
The symptom does not occur.
MR Configurator
C6
The symptom occurs if setup.exe is executed.
C5 or earlier
The symptom does not occur.
PX Developer
PX Developer Monitor Tool
The symptom occurs if setup.exe is executed.
MX Component
The symptom occurs if setup.exe is executed.
TECHNICAL BULLETIN
[3/5]
[Issue No.] FA-A-0210
Product name
Situation
MX Sheet
The symptom occurs if setup.exe is executed.
MX MESInterface-R
The symptom occurs in the following situation:
• The installation of DB Connection Service and DB Connection Service Setting Tool are
executed.
MX MESInterface
The symptom occurs in any of the following situations:
• The installation of MES Interface Function Configuration Tool is executed.
• The installation of DB Connection Service and DB Connection Service Setting Tool are
executed.
GX LogViewer
The symptom does not occur.
CPU Module Logging Configuration Tool
The symptom does not occur.
MELSEC iQ-R series High Speed Data
Logger Module Tool
The symptom does not occur.
High Speed Data Logger Module Tool
The symptom does not occur.
High Speed Data Communication
Module Tool
The symptom does not occur.
BOX Data Logger Configuration Tool
The symptom does not occur.
QnH to QnU conversion support tool
The symptom does not occur.
GX Developer
The symptom occurs if setup.exe is executed.
A/QnA to Q conversion support tool
The symptom occurs if setup.exe is executed.
GX Configurator-AD
GX Configurator-DA
GX Configurator-CT
GX Configurator-TC
GX Configurator-TI
GX Configurator-FL
GX Configurator-PT
GX Configurator-AS
GX Configurator-SC
GX Configurator-QP
GX Configurator-AP
The symptom occurs if setup.exe is executed.
GX Simulator
The symptom occurs if setup.exe is executed.
GX Converter
The symptom occurs if setup.exe is executed.
CC-Link system
master/local
interface board
software package
1.18U or later
The symptom does not occur.
1.17T or earlier
The symptom occurs if setup.exe is executed.
CC-Link IE
Controller Network
interface board
software package
1.20W or later
The symptom does not occur.
1.19V or earlier
The symptom occurs if setup.exe is executed.
CC-Link IE Field Network interface board
software package
MELSECNET/H
interface board
software package
The symptom does not occur.
29F or later
The symptom does not occur.
28E or earlier
The symptom occurs if setup.exe is executed.
TECHNICAL BULLETIN
[4/5]
[Issue No.] FA-A-0210
3. CAUSE
The symptom occurs due to the abnormal behavior of ntvdm.exe, the Windows system module.
We have found that this is caused by a defect in the BIOS or UEFI on the personal computer.
3.1 Investigation Result
As a result of our investigation, we found that the ntvdm.exe loops infinitely.
(1) Analysis result
The following explains the result of analysis. The addresses differ depending on the manufacturer of the
personal computer.
Analysis result of ntvdm.exe
0:000> r
eax=0004ffff ebx=00000200 ecx=00000000 edx=00000000 esi=00042000 edi=00000070
eip=0000f18e esp=000006cc ebp=000006dc iopl=0 vif nv up ei pl zr na pe nc
cs=c000 ss=0000 ds=0000 es=0070 fs=0000 gs=0000 efl=000a0246
c000:f18e ebfe
jmp
F18E
c000:f177 66be00200400
mov
esi,42000h
c000:f17d e8ba7c
call
6E3A
← Call the subroutine
c000:f180 66a900000004
test
eax,4000000h
← Check the returned value
c000:f186 7502
jne
F18A
← Jump if the flag of 0x4000000 is not set
c000:f188 eb03
jmp
F18D
← Jump if the program above does not jump
c000:f18a f9
stc
c000:f18b eb03
jmp
c000:f18d f8
clc
c000:f18e ebfe
jmp
0:000> ub c000:f18e
↓
F190
↓
← Reset the carry flag
F18E
← Infinite loop
(2) Conclusion
The address that goes into the infinite loop may be processed by the BIOS or UEFI option.
The problem may occur in the BIOS or UEFI of the graphic function.
TECHNICAL BULLETIN
[5/5]
[Issue No.] FA-A-0210
3.2 How to Check the Operation of "ntvdm.exe"
The operation can be checked by following the procedure below.
1. Right-click the taskbar of Windows, and then click [Start Task Manager].
2. Select the "Performance" tab in the Windows Task Manager.
3. Check the number of graphs (number of cores) in "CPU Usage History".
Example) Number of cores is '4'
4. Select the "Processes" tab in the Windows Task Manager.
5. Check the value in "CPU" of "ntvdm.exe".
Example) CPU usage of one core is '25'
6. Calculate the CPU usage by multiplying the values which have been obtained in Step 3 and Step 5.
If the CPU usage is around 100%, it indicates that the error is caused by a high-load processing of the
ntvdm.exe.
4. CORRECTIVE ACTION
We have concluded that the MELSOFT products can be installed correctly by modifying the BIOS or UEFI.
If the symptom occurred, please contact the manufacturer of the personal computer used with this bulletin
attached. Obtain the appropriate BIOS or UEFI for your personal computer.
TRADEMARK
Intel is either registered trademarks or trademarks of Intel Corporation in the United States and/or other
countries.
Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries.
The company names, system names and product names mentioned in this manual are either registered
trademarks or trademarks of their respective companies.
In some cases, trademark symbols such as '™' or '®' are not specified in this manual.