Data Sheet 85006-0059 -- Ethernet Device Server Network Interface

Data Sheet 85006-0059 -- Ethernet Device Server Network Interface
GE
Security
EST Fire & Life Safety
Communications
Overview
Standard Features
The NETCOM-1S allows GE Security fire alarm panels to communicate with a PC running FireWorks or ACDB software or a serial printer over Ethernet networks. The NETCOM-1S is ruggedly constructed
industrial grade unit that connects to the fire alarm control panel’s
RS-232 serial port. LEDs on the front of the unit make it easy to
determine its status. Flash ROM memory permits upgraded versions
of operating firmware to be easily downloaded via the serial port.
Power is supplied directly from the Fire Alarm Control Panel, ensuring a reliable and monitored source. For remote printer applications,
an external 120VAC wall mount transformer is supplied.
• Connect alarm panels to a remote fireworks workstation over
TCP/IP, LAN/WANs
The NETCOM-1S encapsulates RS-232 serial data to/from the fire
alarm panel into packets and transports them over 10/100BASE-T
Ethernet to a remote network location where the RS-232 serial data
is reconstructed by either software or hardware means depending
on the application.
• Access Control Database Support over LAN/WAN
• 10/100BASE-T Ethernet interface (RJ45)
• RS-232 Serial connection
• UL-1950 (ITE) Listed
• Configuration and port director software included
• Flash rom for easy software upgrade
The NETCOM-1S is supplied with NETCON-INS Configuration Software that is used to enter a static IP address, set up port, protocol
and data handling configurations. NETDIRECT Communication Port
Director software is also provided to facilitate the use of the NETCOM-1S interface with programs that to not directly support TCP/IP
networking. The program is a 32 bit Windows® based utility that
maps up to 32 communication ports to individual IP addresses.
The NETCOM-1S is suitable for desktop and surface mounting. The
NETCOM-BRKT facilitates mounting one or two NETCOM-1Ss in an
MFC-A enclosure and 3-CHAS7 Chassis.
Ethernet Device
Server Network
Interface
NETCOM-1S
Data Sheet 85006-0059 Issue 2
Not to be used for installation purposes. Page of 4
Application
Installation and Mounting
Fire Alarm Monitoring
Considerable thought and care must be used when combining life
safety equipment and LAN technology. Systems that utilize LAN
network technology for information and reporting purposes ONLY
do not face the network and agency listing restrictions as systems
that use the LAN to transmit control information between the fire
alarm panel and the FireWorks workstation(s). This technology is
listed for monitoring applications only. All life safety applications
using LAN technology should be fully reviewed with the Authority
Having Jurisdiction.
The NETCOM-1S is installed in a NETCOM-BRKT, which fits into the
cabinet options shown below.
Installing the NETCOM-BRKT in a 3-CHAS7
3-CHAS7
Each fire alarm control panel is equipped with a NETCOM-1S
interface that connects the panel to a TCP/IP LAN/WAN. On the
monitoring side of the LAN/WAN, a PC running FireWorks software
is configured to look for the static IP addresses of the NETCOM-1S
interfaces on the LAN/WAN. Panel data is then transferred over the
LAN/WAN to the FireWorks workstation as if the workstation and
the panel were hard wired together.
Access Control Database Support
The interface may be used to permit a remote computer running
the Access Control DataBase (ACDB) program to connect with
a Synergy enabled EST3 panel over an existing LAN/WAN. Simply install a NETCOM-1S in the EST3 panel and use the supplied
NETDIRECT communication port director software utility and the
ACDB software in remote PC equipped with a conventional network
interface card.
Remote System Printer
This application requires one NETCOM-1S at the FACP and a second
NETCOM-1S interface at the PT-1S printer.
NETCOM-BRKTs
Installing the NETCOM-BRKT in an MFCA cabinet
MFC-A cabinet
Compatible Equipment
·
·
·
·
·
EST3 /Synergy Networks
EST2 Standalone FACP
IRC-3/FCC Networks
PT-1S Serial Printers
NETSW-EIS6-xM Network Switches
Technical Requirements
· Each interface requires a static IP address assigned by the network administrator.
· An RJ-45 network jack must be located within 5 feet, of the interface.
· When connecting remote panels to a GE Security FireWorks
system, network ping time can not exceed 500ms.
· Sufficient network bandwidth shall be made available at all times.
Typical requirements for these applications are 1.8 Kbytes/Sec.
· All network security is the responsibility of the network administrator.
NETCOM-BRKT
Connecting a NETCOM-1S to the NETCOM-BRKT
Holes for top device
NETCOM-BRKT
NETCOM-1Ss
· The NETCOM-1S power source should be provided with battery
backup to ensure reliable service during a power outage.
Engineering Specification
The FACP to LAN/WAN network interface shall be an industrial
grade 10/100BASE T Ethernet® device server. The interface shall
have diagnostic LEDs on the front of the unit make it easy to
determine its status, and incorporate flash ROM memory facilitating upgrading the operating firmware. Power shall supplied directly
from the FACP, ensuring a reliable and monitored power source.
Holes for bottom device
Data Sheet 85006-0059 Issue 2
Not to be used for installation purposes. Page of 4
Typical Configurations
Serial RS-232 connection
[2]
FireWorks to FACP
FireWorks with
network interface card
Device server
Fire alarm
control panel
Device server
Fire alarm
control panel
Device server
Fire alarm
control panel
Ethernet connection
Ethernet connection
[1]
Notes
[1]
Ethernet network
LAN/WAN
Access Control DataBase (ACDB)
Serial RS-232 connection
[2]
ACDB with
NETDIRECT software
and network interface card [3]
Notes
Device server
Network
control panel
Device server
Network
control panel
Device server
Network
control panel
Ethernet connection
Ethernet connection
[1]
[1]
Ethernet network
LAN/WAN
[1] Ethernet connection: CAT 5/6 cable,
maximum distance
300 feet (100 m)
[2] Serial RS-232 connection: Maximum
distance 50 feet (15 m)
3 Network ping time should not exceed
500 ms.
[1] Ethernet connection: CAT 5/6 cable,
maximum distance
300 feet (100 m)
[2] Serial RS-232 connection: Maximum
distance 50 feet (15 m)
[3] NETDIRECT software is on the NETCOM-CD supplied with NETCOM-1S
FireWorks with ACDB to FACP
Computer with FireWorks
and ACDB with
NETDIRECT software and
network interface card [3]
Serial RS-232 connection
Ethernet connection
Ethernet connection
[1]
[1]
[2]
Device
server
Fire alarm
control panel
Device
server
Device
server
Ethernet network
LAN/WAN
Notes
Fire alarm
control panel
Device
server
Device
server
Device
server
[1] Ethernet connection: CAT 5/6 cable,
maximum distance
300 feet (100 m)
[2] Serial RS-232 connection: Maximum
distance 50 feet (15 m)
[3] NETDIRECT software is on the NETCOM-CD supplied with NETCOM-1S
4 Network ping time should not exceed
500 mS.
Fire alarm
control panel
FireWorks to CCTV
Ethernet connection
[1]
Serial RS-232 connection
[2]
CCTV controller
Ethernet network
LAN/WAN
Device server
[3]
Serial RS-232 connection
[2]
Device server
Coax cable connection
Fire alarm
control panel
[1] Ethernet connection: CAT 5/6 cable,
maximum distance
300 feet (100 m)
[2] Serial RS-232 connection: Maximum
distance 50 feet (15 m)
[3] Coax cable connection
4 Network ping time should not exceed
500 ms.
Cameras
FACP to Remote Printer
Serial RS-232
connection
[2]
Notes
Ethernet connection
[1]
Device server
Ethernet connection
[1]
Ethernet network
LAN/WAN
Serial RS-232 connection
[2]
Device server
Notes
Printer or
3-VDUT
or VDU-3
[1] Ethernet connection: CAT 5/6 cable,
maximum distance
300 feet (100 m)
[2] Serial RS-232 connection: Maximum
distance 50 feet (15 m)
Data Sheet 85006-0059 Issue 2
Not to be used for installation purposes. Page of 4
GE
Security
U.S.
T 888-378-2329
F 866-503-3996
Canada
T 519 376 2430
F 519 376 7258
Asia
T 852 2907 8108
F 852 2142 5063
Australia
T 61 3 9259 4700
F 61 3 9259 4799
Europe
T 32 2 725 11 20
F 32 2 721 86 13
Latin America
T 305 593 4301
F 305 593 4300
www.gesecurity.com/est
© 2006 General Electric Company
All Rights Reserved
Specifications
Agency Listings
Installation
Network Interface
Network
Connector
Supported Protocols
Serial Interface
Interface Connector
Data Rates
Characters
Parity
Stop Bits
Control Signals
Flow Control
Management
Processor CPU Memory
Diagnostic LEDs
Dimensions (HWD)
Power Requirements
CE, CSA, FCC-B, TUV, UL/cUL-1950
Desktop, surface mount, or optional NETCOM-BRKT bracket
Ethernet 10Base-T, 100Base-TX
RJ-45
ARP, UDP/IP, TCP/IP, ICMP, SNMP, AutoIP, DHCP, TFTP, Telnet, HTTP
RS-232, RS-422, or RS-485
DB-25 (female, DCE configuration)
300 to 115,200 bps
7 or 8 data bits
Odd, even, none
1 or 2 RTS, CTS, DSR, DTR, DCD
XON/XOFF, RTS/CTS
Serial login, SNMP, telnet login
Enhanced 80186,48 MHz 256KSRAM,1MB flash
10 Link/Activity (green), 100 Link/Activity (green), Collision (red),
Diagnostics (red), Status (green)
0.9in x 2.5in x 3.5in (2.3cm x 6.4cm x 9.0cm)
9 to 30 VAC/VDC @ 1 watt. (40 mA @ 24 VDC) 120VAC wall transformer
included
Environmental
Operating Temperature 41°F to 122°F (5° to 50°C)
Storage Temperature -40° to 151°F (-40° to 66°C)
Ethernet is a trademark of Xerox Corporation.
Ordering Information
Catalog
Number
NETCOM-1S
Description
Ethernet Device Server Network Interface – 10/100BASE-T
Related Equipment
Bracket for mounting two (2) NETCOM-1S, one (1) NETCOM-1F, or one
NETCOM-BRKT
(1) NETSW-EIS6-xM in an MFC-A Enclosure or 3-CHAS7 chassis
MFC-A
Multifunction Fire Cabinet
Ship Wt.
lb (kg)
3.0 (1.5)
1 (0.45)
19 ( 7.26)
Data Sheet 85006-0059 Issue 2
Not to be used for installation purposes. Page of 4