CA 1886 CA 1888
C.A 1886
C.A 1888
For maintenance and building inspections,
RayCAm sees everything!
High-Resolution
Thermal Cameras
es
ed imag
to infrar
s
e
g
a
im
al
From re
l
Thorough analysis with comprehensive parameterization
l
Large screen for easier reading
l
T
emperature up to 600 °C
l
T
hermal sensitivity from 0.08 °C to less than 0.05 °C
l
Matrix up to 384 x 288
Certification granted on the basis of a single
test Available at www.cnpp.com
N° 2010-0020 - N° 2010-0021
ADVANTAGES
The RayCAms’ design and the technologies used to manufacture them provide a wide
range of advantages.
Their ergonomic design means comfortable measurement even in places where access
is difficult:
● IP 54 leakproofing
● excellent legibility thanks to its multidirectional screen
● comfortable handling due to its pistol shape
Performance
●
●
●
●
●
New functions
automatic detection of hottest/coldest point
parameter settings affecting measurement:
• adjustable emissivity
• adjustment of measurement distance
• parameters for defining relative humidity
and environmental temperature
parameterizable alarms
isotherm function
storage capacity of 1,000 radiometric images
organized in 250 folders
and back-up on SD card
●
●
●
●
●
an analytical tool providing a thermal profile along
a horizontal line,
the possibility of integrating up to five Min, Max
and Average analyses on adjustable areas,
temperature difference measurements
between two tools or in relation to a reference
temperature,
4 types of isotherms also available as standard
features,
possibility of assigning different emissivities
according to the analytical tools used.
With the new RayCAms, users can choose the mode for viewing the target: infrared, real or a mix of both with the
"MixVision" function. This allows you to adjust the transparency (in %) of the infrared image in relation to the real
image, thus helping to identify problem areas immediately.
Lens Specifications
The C.A 1886 is delivered with a 20° x 15° lens.
The C.A 1888 is equipped with a 24° x 18° lens.
0.1 m 0.3 m0.5 m
20° x 15° 2.2 mrad 10 cm
HFOV (m) 0.030.10
0.17
1 m
2 m
6 m 10 m 30 m 100 m
0.350.702.113.52
10.57
35.26
VFOV (m)
0.02 0.07
0.13
0.26 0.52 1.572.637.8926.33
IFOV (mm)
0.22 0.66
1.10
2.20 4.40 13.2222.0466.12220.40
SMO (mm)
0.66
6.60
1.98 3.30
13.20
39.66
66.12 198.36 661.20
24° x 18° 1.3 mrad 10 cm
HFOV (m)0.05
0.15
0.250.5
134.99
14.98
49.92
VFOV (m) 0.040.11
0.19
0.370.752.253.74
11.23
37.44
IFOV (mm)
0.13
0.39 0.65
1.3
2.6
7.8
13
39
130
SMO (mm)
0.39
1.17 1.95
3.9
7.8 23.4
39
117
390
ELECTRICAL APPLICATIONS
Circuit-breaker/Generator
THERMAL APPLICATIONS
Air leaks/energy losses
• detection of damaged fuses
and bad connections
• energy consumption monitoring /
building inspections
• verification of correct heat diffusion
in the generator
• location of losses (heating,
insulation, etc.)
MECHANICAL APPLICATIONS
Electric motors
• detection of internal component
anomalies or malfunctions to prevent
motor overheating
ELECTRONIC APPLICATIONS
Components/printed circuits
• thermal profile and heat diffusion
on a PCB
• detection of component overheating
• HFOV and VFOV represent the horizontal and
vertical fields of view, respectively.
• IFOV corresponds to the camera’s spatial resolution,
i.e. what a detector sees.
• SMO (Smallest Measurable Object): to ensure
correct measurement, the target observed must
cover at least three detectors, i.e. SMO = 3 IFOV.
RayCAm Report Standard software
Delivered with the RayCAm Report STANDARD software
Thermal Image / Real Image /
With the RayCAm Report Standard, you can combine your thermogram with
a real image. This allows you to identify the fault or dysfunction so that you can make
the appropriate corrections!
The MixVision function is available as a standard feature on the RayCAms.
Users can reinitialize the merge function by modifying the IR/real percentage
to suit your requirements and ensure clearly-interpretable reports: this percentage
can be adjusted from 0 to 100 % !
Analysis mode
This new mode can be used to open one or more images, add various analytical
tools and obtain a summarized presentation of all the results in a table.
This mode is useful for first-level analysis when you simply want a rough idea of
the temperature values without saving the analyses.
Genuine, accurate analysis
If a characteristic on the radiometric image is changed, the other values are
automatically recalculated.
RayCAm Report Standard allows you to define the emissivity of each
point in the thermogram, an essential feature when the thermogram
contains different materials.
Choose a different configuration for
each analytical tool inserted on your
thermogram.
A wide range of possibilities:
●
specify a different emissivity from that of
the thermogram as a whole
●
display a value label next to the tool
●
display the Max/Min temperature within an area
of analysis
RayCAm Report Standard is the ideal tool for analysing the results and creating customized reports.
Its interface is so simple that anyone can learn to use it very quickly.
All the analysis functions are accessible via the toolbar.
Depending on their requirements, users can position various elements:
●
Cursors (automatic display of the temperature at the point selected).
●
Thermal profile (automatic display of the Min/Max/Average temperatures of the line).
●
A square or circle for area analysis (ideal for Min/Max/Average temperature
comparisons between terminals, for example).
●Result
tables quickly display all the data/analytical tools on the thermogram
automatically.
●The
"Max" function automatically indicates the hottest point in the whole thermogram
or in a predefined area of analysis.
●Polygons
●A
and polylines for more precise analysis of certain areas in the thermogram.
barchart for studying the temperature distribution according to several intervals.
TECHNICAL SPECIFICATIONS
Standard temp. range
Temp. range with option
Accuracy
IR image
Field of view
Spatial resolution
Min. focusing distance
Focusing
Real image
Min. focusing distance
IR-Merge
Image size
Emissivity correction
Parameter settings
Measurement tools
Comments
Storage
Storage type
Screen
Battery
Battery recharging
Protection
A wide range of
accessories for
measurements in
optimum conditions:
● Video
cable for display on external
screen
● RayCAm Report Standard software
for processing the data
● Operation on internal batteries or
mains adapter
Accessories available as an
option:
● Mains
adapter for continuous use
accessories
● Sun-shade to make the screen easy
to read even in bright lighting
● Tripod adapter for hands-free use and
operation in a fixed position
● Bluetooth
* 9 Hz outside the European Union
Standard state at delivery:
C.A 1886 or C.A 1888: delivered in a case with 1 battery charger, 2 batteries,
a 2 GB mini-SD Card, 1 SD card reader, 1 video cable, RayCAm Report Standard software
and a measurement report.
References to order
Accessories and replacement parts
C.A 1886................................................... P01651260
C.A 1886 - 9 Hz.......................................... P01651260E
C.A 1886 high temperature 1,000 °C........... P01651261
C.A 1886 high temperature 1,500 °C........... P01651262
C.A 1886 Bluetooth..................................... P01651263
C.A 1888................................................... P01651270
C.A 1888 - 9 Hz.......................................... P01651270E
C.A 1888 high temperature 1,000 °C........... P01651271
C.A 1888 high temperature 1,500 °C........... P01651272
CA 1888 Bluetooth...................................... P01651273
Other configurations C.A 1886..................... CA1886-CFG
Other configurations C.A 1888..................... CA1888-CFG
Sun-shade.......................................... P01651531
Photo tripod adapter........................... P01651526
Lens cap............................................ P01651522
Battery.............................................. P01296041
Battery charger ................................. P01296043
Mains power supply............................ P01651527
In-vehicle battery charger
(cigarette lighter)...................................... HX0061
Thermography training ................ Please contact us
FRANCE
Chauvin Arnoux
190, rue Championnet
75876 PARIS Cedex 18
Tel: +33 1 44 85 44 86
Fax: +33 1 46 27 95 59
export@chauvin-arnoux.fr
www.chauvin-arnoux.fr
united kingdom
Chauvin Arnoux Ltd
Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk
Dewsbury, West Yorkshire - WF12 7TH
Tel: +44 1924 460 494
Fax: +44 1924 455 328
info@chauvin-arnoux.co.uk
www.chauvin-arnoux.com
middle east
Chauvin Arnoux Middle East
P.O. BOX 60-154
1241 2020 JAL EL DIB (Beirut) - LEBANON
Tel: +961 1 890 425
Fax: +961 1 890 424
camie@chauvin-arnoux.com
www.chauvin-arnoux.com
For assistance and ordering
906211343 - Ed. 2 - VS 02/2013 - Non contractual document. Confirm specifications before ordering.
Detector
Type
Frequency
Sensitivity (NETD)
C.A 1886
C.A 1888
Detector Specifications
160 x 120
384 x 288
UFPA microbolometer, 8-14 microns
50 Hz*
0.08 °C at 30 °C
0.05 °C at 30 °C
Temperature Measurement
-20 °C to +600 °C
Up to 1,500 °C
±(2 °C or 2 %)
image performance
Yes
20° x 15°
24° x 18°
2.2 mrad
1.1 mrad
10 cm
Manual
Yes
10 cm
Complete IR-Merge functions
IR image in real image from 0 to 100 %
640 x 480 pixels
Other Functions
Yes
Emissivity (possibility of assigning different emissivity values according to the
analytical tools used), environmental temperature, distance, relative humidity.
4 cursors: 3 manual cursors + 1 auto.
Max/Min detection on adjustable area, isotherm, high/low alarm.
Voice annotations (option)
1,000 (radiometric format) + 250 folders
2 GB mini-SD Card
3.5 inches, multidirectional
General
Battery life: 3 hrs (continuous use)
External battery charger
IP 54
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising