Appendix A: Status Indicators

Appendix A: Status Indicators
Appendix A
Status Indicators
A.1
Front Indicators
A.1.1
Switch Indicators
Front panel LEDs are located on the right side of the chassis and display system, fan, and power supply
status.
Figure A-1 displays the DCS-7050QX-32S front panel LEDs
System Status LED
Fan Status LED
Power Supply 1 Status LED
Power Supply 2 Status LED
Figure A-1: System Status Indicators
Quick Start Guide: 7000 Series 1 RU-Gen 3 Data Center Switches
27
Front Indicators
Status Indicators
Table A-1 Switch Indicators LED States (Front)
LED Name
LED State
Device Status
System Status LED
Blinking Green
System is powering up.
Green
Normal operations. Due to power supply and fan redundancy,
this LED will remain green if a single fan or power supply is
missing or in a failed state.
Blue
The locater function is active.
Amber
Two or more fans (any combination of fan modules or PSU
fans) are disconnected or malfunctioning. The switch will
automatically execute a “graceful shutdown” shortly.
Green
All fan and power modules are operating normally.
Amber
Single fan module is removed or malfunctioning. It is also
amber when a PSU is completely removed or has a stuck
fan rotor.
Red
Two or more fans (any combination of fan modules or PSU
fans) are disconnected or malfunctioning. The switch will
automatically execute a “graceful shutdown” shortly.
Green
PSU is functioning and fully operational. AC is present, Aux
output is ON, and Main output is ON.
Off
PSU has been removed or is not operating properly due to AC
cord being unplugged, its fan rotor being stuck, or an internal
fault.
Fan Status LED
PSU [1:2] Status LED
A.1.2
Port Indicators
Port LEDs, located in the vicinity of their corresponding ports, provide link and operational status.
Figure A-2 displays the Port LED location on the DCS-7050QX-32S switch.
7050QX-32S
1
2
SFP+
3
4
5
6
7
8
9
10
QSFP #5
Port 1 LEDs
Port 2 LEDs
Port 3 LEDs
Port 4 LEDs
Figure A-2: Port LEDs
Table A-2 provides status conditions that correspond to port LED states. Port LED behavior for QSFP+
and SFP+ ports is consistent.
Table A-2 Port LED States (Front)
28
LED State
Status
Off
Port link is down.
Green
Port link is up.
Quick Start Guide: 7000 Series 1 RU-Gen 3 Data Center Switches
Status Indicators
Rear Status Indicators
Table A-2 Port LED States (Front)
A.2
LED State
Status
Yellow
Port is software disabled.
Flashing Yellow
Port failed diagnostics.
Rear Status Indicators
Fan and power supply modules are accessed from the rear panel. Each fan and power supply module
contains an LED that reports the module status.
Fan Status LEDs are on the fan modules, as displayed in Figure A-3.
Table A-3 provides status conditions that correspond to fan status LED states.
The AC Power Supply Status LEDs are on the power supply modules, as displayed in Figure A-4.
Fan Status LED
Figure A-3: Fan Status LED
Table A-3 Fan Status LED States (Rear)
LED State
Status
Off
The fan module is not detected. If it is inserted, it may not be seated properly.
Green
The fan is operating normally. This LED state is exclusive to its fan module, and
independent of the states of its neighboring fans and power supplies.
Red
The fan has failed.
Power Supply Status LED
Figure A-4: AC Power Supply Status LED
Quick Start Guide: 7000 Series 1 RU-Gen 3 Data Center Switches
29
Rear Status Indicators
Status Indicators
Table A-4 provides status conditions that correspond to the AC power supply status LED states.
Table A-4 AC Power Supply Status LED States (Rear)
Power
Supply
State
PWR-500AC-F
PWR-500AC-R
PWR-745AC-F
PWR-745AC-R
PWR-747AC-F
PWR-747AC-R
PWR-750AC-F
PWR-750AC-R
Input
power
present
Normal
operation
Green
Green
Green
Green
Input
power
present
Power
Supply
fault
Yellow
Yellow
Yellow
No Input
power
Supply
installed
in chassis
Off
Off
Off
Blinking
Yellow
Input
power
present
Supply
not
installed
in chassis
Green
Green
Green
Blinking
Yellow
The DC Power Supply Status LEDs are on the power supply modules, as displayed in Figure A-5.
STATUS
PWR-500DC-F
-48 --- -60V
, 15A
+
-
RTN -48Vdc
500W
Figure A-5: DC Power Supply Status LED
Table A-5 provides status conditions that correspond to the DC power supply status LED states.
Table A-5 DC Power Supply Status LED States (Rear)
Power Supply State
Input power present
Normal operation
30
PWR-500DC-F
PWR-500DC-R
PWR-1900DC
Green
Green
Quick Start Guide: 7000 Series 1 RU-Gen 3 Data Center Switches
Status Indicators
Rear Status Indicators
Table A-5 DC Power Supply Status LED States (Rear)
PWR-500DC-F
PWR-500DC-R
PWR-1900DC
Input power present
Power Supply fault
Blinking Yellow
Blinking Yellow
No Input power
Supply installed in chassis
Off
Off
Input power present Supply
not installed in chassis
Blinking Yellow
Blinking Yellow
Power Supply State
Important! You can narrow down the error condition by logging in to the switch to view the specific device state.
Refer to the Arista User Manual’s Switch Environment Control chapter, under the topic Viewing
Environment Status, for further information on the show environment commands.
Quick Start Guide: 7000 Series 1 RU-Gen 3 Data Center Switches
31
Rear Status Indicators
32
Status Indicators
Quick Start Guide: 7000 Series 1 RU-Gen 3 Data Center Switches