LPF-40 series
LPF-40
40W Single Output Switching Power Supply
series
■ Features :
•Universal AC input / Full range (up to 305VAC)
•Built-in active PFC function
•High efficiency up to 89%
•Protections: Short circuit / Over current / Over voltage / Over temperature
•Cooling by free air convection
•Fully isolated plastic case
•Fully encapsulated with IP67 level (Note.6)
•Class Ⅱ power unit, no FG
•Class 2 power unit
•Suitable for LED lighting and moving sign applications
•Compliance to worldwide safety regulations for lighting
•Suitable for dry / damp / wet locations
•5 years warranty
F
110
M
M
SELV
IP67
( for 48V,54V only)
( except for 48V,54V )
SPECIFICATION
MODEL
DC VOLTAGE
LPF-40-12
LPF-40-15
LPF-40-20
LPF-40-24
LPF-40-30
LPF-40-36
LPF-40-42
LPF-40-48
LPF-40-54
12V
15V
20V
24V
30V
36V
42V
48V
54V
9 ~ 15V
12 ~ 20V
14.4 ~ 24V
21.6 ~ 36V
25.2 ~ 42V
28.8 ~ 48V
32.4 ~ 54V
1.12A
0.96A
0.84A
0.76A
CONSTANT CURRENT REGION Note.4 7.2 ~12V
OUTPUT
RATED CURRENT
3.34A
2.67A
2A
1.67A
18 ~ 30V
1.34A
RATED POWER
40.08W
40.08W
40W
40.08W
40.2W
40.32W
40.32W
40.32W
41.04W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
250mVp-p
350mVp-p
VOLTAGE TOLERANCE Note.3 ±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±2.0%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
Note.7 1000ms, 80ms / 115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
16ms/230VAC
Note.5 90 ~ 305VAC
16ms/115VAC at full load
127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
84%
86%
88%
85%
87%
0.6A / 115VAC
0.3A / 230VAC
0.25A / 277VAC
COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER CURRENT
PROTECTION
1200ms, 80ms / 230VAC
88%
90%
90%
54 ~ 63V
59 ~ 66V
<0.75mA / 240VAC
Note.4
SHORT CIRCUIT
OVER VOLTAGE
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
34 ~ 40V
15 ~ 17V
17.5 ~ 21V 23 ~ 27V
28 ~ 35V
Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS Note.6
41 ~ 49V
20 ~ 95% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13
approved ; design refer to UL60950-1, TUV EN60950-1
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
EMC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3
ISOLATION RESISTANCE
46 ~ 54V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE
EMC EMISSION
88.5%
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
438.8K hrs min. MIL-HDBK-217F (25℃)
162.5*43*32mm (L*W*H)
DIMENSION
0.44Kg; 32pcs/15.08Kg/0.93CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
EMC IMMUNITY
MTBF
OTHERS
NOTE
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:LPF-40-SPEC 2013-11-27
LPF-40
40W Single Output Switching Power Supply
Mechanical Specification
Case No. LPF-60B
series
Unit:mm
162.5
3.5
300±20
3.5
3.6
3.6
T case
300±20
+V(Red)
-V(Black)
60
13
ψ
3.5
SJTW 18AWG×2C
43
ψ
AC/N(Blue)
AC/L(Brown)
SVT 18AWG×2C
3.5
32
※ T case: Max. Case Temperature.
Recommend Mounting Direction
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
O.L.P.
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-40
-30
0
15
30
40
50
AMBIENT TEMPERATURE (℃)
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:LPF-40-SPEC 2013-11-27
40W Single Output Switching Power Supply
LPF-40
series
Power Factor Characteristic
PF
Constant Current Mode
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
.9 9
.9 8
.9 7
.9 6
.9 5
.9 4
.9 3
.9 2
.9 1
0 .9
.8 9
.8 8
.8 7
.8 6
.8 5
.8 4
277VAC
230VAC
115VAC
50%
60%
70%
80%
90%
100%
(40W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
LPF-40 series possess superior working efficiency that up to 90% can be reached in field applications.
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
72
71
70
277VAC
230VAC
115VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Vo(%)
100
(B)
Constant
Current area
(A) Constant
Voltage area
Should there be any compatibility issues, please contact MEAN WELL.
60
(max.)
(C)
Hiccup
Protection
50
95
Io (%)
Typical LED power supply I-V curve