Tablet Oscilloscope tBook Mini TO1000M series Data Sheet

Tablet Oscilloscope tBook Mini TO1000M series Data Sheet
Tablet Oscilloscope tBook Mini
TO1000M series
Data Sheet
Shenzhen Micsig Instruments Co., Ltd.
Dec 2016
Shenzhen Micsig Instruments Co., Ltd.
TEL: +86-755-86-8860880
FAX: +86-755-26078507-818
WEB: www.micsig.com
Email: sales@micsig.com
ADD: 305 Block A, CLOU Building, Baoshen RD,
North Area, Nanshan Science&Technology Park,
Nanshan District, Shenzhen, Guangdong, China. 518000
Tablet Oscilloscope tBook mini
Model
TO1102M
TO1104M
channels
2
4
Bandwidth
100M
100M
Risetime
3.5ns
3.5ns
Real time sampling rate(1 Ch)
1G Sa/s
1G Sa/s
Real time sampling rate (2 Ch)
500M Sa/s
500M Sa/s
Real time sampling rate (4 Ch)
-
250M Sa/s
Peak mode(1 Ch)
1ns
1ns
Peak mode (2 Ch)
2ns
2ns
Peak mode (4 Ch)
-
4ns
Memory depth (1 Ch)
2.8M
2.8M
Memory depth (2 Ch)
1.4M
1.4M
Memory depth (4 Ch)
-
0.7M
Memory depth (2 Ch)
1.4M
1.4M
Memory depth (4 Ch)
-
0.7M
Standard
Specifications
Vertical system
Bandwidth limitation
20MHz
Input coupling
DC, AC, GND
Input impedances
1MΩ ±1%||14.5pF±3pF
Vertical resolution
8bits
DC gain accuracy
<±2% ( 1MΩ )
vertical scale
1mV/div to 5V/div ( 1MΩ )
Channel to channel
≥40dB ( 100:1 )
Offset range
±6div
Maximum input voltage
CAT I 300V ( 1MΩ )
Horizontal system
Time base range
2ns/div ~ 1ks/div
Time base delay range
-14 divisions to 14ks
Time base accuracy
±20ppm
Sampling system
Sampling mode
Peak sampling
Sample rate 1G Sa/s
Real time sample rate
All the sampling glitches in scanning rate are narrow to single channel 1 ns, dual
channel 2 ns .four channel 4ns
Max duration in the max sampling
rate
Sample rate 1G Sa/s
Sample rate 500MSa/s
Sample rate 250MSa/s
28/14ms
56/28ms
56/28ms
Average
Average of sampling for N times
Data Sheet
1
Tablet Oscilloscope tBook mini
N is chosen from 2, 4, 8, 16, 32, 64, 128, 256
Envelope of sampling for N times
Envelope
N is chosen from 2, 4, 8, 16, 32, 64, 128, 256, ∞
Trigger system
Trigger mode
Normal, Auto, and Single
Trigger coupling
DC, AC, HF reject, LF reject, noise reject
hold off range
200ns to 10s
Trigger type
Edge
Pulse Width
Logic
Positive, negative, or either slope on any channel input. Coupling includes DC, AC, HF reject, LF
reject, and noise reject.
Trigger on width of positive or negative pulses that are>, <, =, ≠, or inside/outside a
specified period of time (8ns~10s).
Trigger when any logical pattern of channels goes false or stays true for specified period of time
(8ns~10s). Any input can be used as a clock to look for the pattern on a clock edge. Pattern (AND,
OR, NAND, NOR) specified for all input channels defined as High, Low, or Don’t Care
Video trigger
Time out
Slope
Dwart PW
Nth edge
Trigger on all lines or individual lines, odd/ even or all fields on PAL/625SECAM、NTSC/525、720P、
1080I、1080P video signals.
Trigger on an event which remains high, low, oreither, for a specified time period. Selectable from
Positive slope (Great than, lower than, within specific interval)
Negative slope (Great than, lower than, within specific interval)
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing
the first again. Event can be time- or logic qualified.
Edge type: Risingm Falling
Idle time: 16ns to 4s
Number of edges 1 to 65535
Waveform measurement
Cursor
Horizontal Cursor, Vertical Cursor, Cross Cursor
Auto measurements
23, Measurements include: Period, Frequency, Rise Time, Fall Time, Delay,
Positive duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse
Width, Burst Width, Positive Overshoot, Negative Overshoot, Phase, Peak to
Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS.
Waveform math
Dual Waveform
FFT
Add, subtract, multiply, and divide waveforms
Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT
Window to Rectangular, Hamming, Hanning, or Blackman-Harris.
Display system
Display type
8 inches TFT LCD
Display resolution
800*600
Max touch point on touch screen
5 points
Operation way
Full touch
Afterglow time
Auto, 10ms to 10s, ∞
Time Base format
YT, XY, Roll, Zoom
Expansion bench mark
Center, Trigger Position
Data Sheet
2
Tablet Oscilloscope tBook mini
Waveform display
Brightness is adjustable, point ,Line
Grid
14*10 div, Brightness of the grid is adjustable
Grey level
256 level
Time
YES
Language
English, Chinese, and customized
Storage
Storage media
Local, U Disk
Built-in storage
8G
Storage format
csv , wav,bin
Waveform storage number
Unlimited
waveform storage name
Support
display the
quantity
reference
waveform
4 piece
screenshot
Support
User setting number storage
Unlimited
User name setting
Support
Flash format
Comply with industry standards
Interface
USB2.0 interface
Support USB mass storage devices, can read and write
Micro USB2.0 interface
1, support read and write
DC interface
1, for charging
Probe calibration signal output
frequency
1KHz, 2Vpp
LAN
Support
Micro HDMI
Optional
Wifi
Optional
Power source
Power source voltage
100 to 240V AC, 50/60Hz
Power consumption
<60W
Fuse
12V DC, 5A
Built-in Battery(Optional)
7.4V, 8000mAh
Environment
Temperature
Operating
Non-operating
0℃ to 45℃
-40℃ to 60℃
Humidity
Operating
Non-operating
5% to 85%, 25℃
5% to 90%, 25℃
Altitude
Operating
Non-operating
<3000m
<12000m
Physical characteristics
Data Sheet
3
Tablet Oscilloscope tBook mini
Dimensions
Height
Width
Depth
210mm
250mm
55mm
Weight
Net
2CH Bare
4CH Bare
1040g
1125g
Ordering information
Step 1:Select tBook_mini series model
tBook_mini family
TO1102M
Tablet oscilloscope tBook mini, 100MHz 2 analog channels, Max sample Rate
Analog channel up to1G Sa/s
TO1104M
Tablet oscilloscope tBook mini, 100MHz 4 analog channels, Max sample Rate
Analog channel up to1G Sa/s
Standard accessories
Tablet oscilloscope
Power plug
Power adapter
Probes
1
1
1
probes spec depends on oscilloscope model.2 pcs for 2 channel, 4 pcs for 4 channel
10X, Input capacitance: 1X: 85pF-120p, 10X, 16pF-20pF, Input Voltage: 1X: <300V
DC +Peak AC, 10X: <600V DC +Peak AC