Solid State Relays Industrial, 3-Phase SS Models: 3PSS60D75 S

Solid State Relays Industrial, 3-Phase SS Models: 3PSS60D75 S
Solid State Relays
Industrial, 3-Phase SS
Models: 3PSS60D75 S (Standard Din-rail)
3PSS60D75 R (Retro Fit)
• 3-phase Solid State Relay
• Zero switching
• Rated operational voltage: 600 VAC
• Control voltage 4-32 VDC
• Integral snubber network
• Built-in varistor
• IP 10 back-of-hand protection
• LED indication of control input
• Heat Sink and 24 VDC Fan Included
Optional 120 VAC Fan (Add -120 to P/N)
Example (3PSS60D75 S-120)
Product Description
Thermal Specifications
A Solid State Relay family designed to switch various loads
such as heating elements, motors and transformers. The
relay is capable of switching high voltages up to 600 VAC rms.
Operating temperature
Storage temperature
General Specifications
Operational voltage range
Blocking voltage
Operational frequency range
Overvoltage category
Pollution degree
Heat Sink Fan 24 VDC Standard
Heat Sink Fan 120 VAC Optional
Markings
42-660 VAC
1600 Vp
45 to 65 Hz
III
3
1.4 WATTS & 58 mA
3.6 WATTS & 55 mA
|
Output Specifications
Rated operational current
AC51 @ Ta=25°C
AC53a @ Ta=25°C
Minimum operational current
Rep. overload current t=1 s
Non-rep. surge current t = 10 ms
Off-state leakage current
I2t for fusing t = 10 ms
On-state voltage drop
Critical dV/dt off-state
75 AMPS rms
20 AMPS rms
400 mA rms
< 150 A rms
1150 Ap
< 3 mA rms
6600 A2s
≤ 1.6 V rms
≥ 500 V/µs
Input Specifications
Control voltage range
Pick-up voltage
Drop-out voltage
Input current
Response time pick-up
Power output = 50 Hz
Response time drop-out
Power output = 50 Hz
All data specified at Ta=25°C
4-32 VDC
3.8 VDC
1.2 VDC
≤ 23 mA
10 ms
10 ms
E 62767
-30° to 80°C (-22° to 158°F)
-40° to 100°C (-40° to 212°F)
Isolation
Rated isolation voltage
Input to output
Output to case
≥ 4000 VAC rms
≥ 4000 VAC rms
Total Weight
S
R
Grams
Ounces
1,370
48.3
1,473
52
Housing Specifications
Material
Base plate
Potting compound
Noryl
Copper, nickel-plated
Polyurethane
Power terminal
Mounting screws
Mounting torque
Wire size
Max.
Min.
Relay
Mounting screws
Mounting torque
Control terminal
Mounting screws
Mounting torque
Wire size
Load Current per pole in AAC
The built-in varistor for heavy industrial applications. For
higher reliability and load cycle capability three semiconductor
power units are bonded directly to the substrate.
|
M5
≤ 2.5 Nm (22 in lbs)
2 x 6 mm2 (AWG 8)
2 x 1 mm2
M5
≤ 1.5 Nm (13 in lbs)
Max.
Min.
M4
≤ 0.5 Nm (5 in lbs)
2 x 2.5 mm2 (AWG 14)
2 x 1 mm2
80
70
60
50
40
2 Pole
For 2 Pole usage
use L1 & L3
30
20
3 Pole
10
25°
77°
35°
95°
45°
113°
55°
131°
65°
149°
Surrounding Ambient Temperature
75°
167°
85°C
185°F
Dimensions
Model S
4.425
3.550
4.754
.477
.198
3.550
.166 X .190 (2 HOLES)
ALIGNS W/SLOTS BELOW
L1
L2
3PSS60A75
AC51: 75A 600 VAC
4.694
L3
L1 L2 L3 A1
A1
~
T1 T2 T3 A2
VCC: 24-275 VAC
24-50 VDC
A2
~
AC53a: 20A 600 VAC
E 62767
T1
FAN
.173
.504
|
T2
M5 TH’D
2 PLACES
T3
FAN
3.653
.166
3.550
3.550
Model R
4.410
Includes Retro-Fit Back Plate
3.125
.205 X .402 DIA.
KEYHOLE (2 REQ.)
For direct replacement with
standard 2 & 3 pole Mercury
Relays. Using the same mounting
holes.
1.938
2.690
Bracket adds 3/16” to depth
.205
BOTH SIDES
MDI Inc
Post Office Box 710
Edwardsburg, Michigan 49112-0710
Phone (269) 663-8574 - (800) 634-4077
Fax (269) 663-2924 - www.mdius.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising