Multi-Channel
Sound/Vibration Measurement System
Flexible Multi-Channel Configuration Handles Many Measurement Scenarios
Sound Level Meter Unit
Vibration Level Meter Unit
Interface Unit
UN-14
UV-15
UV-22
The Multi-Channel Sound/Vibration Measurement System offers unprecedented flexibility.
Freely combine units for applications such as acoustic measurements,
wide range vibration level measurements, or simultaneous monitoring of noise and vibration levels.
Sound Level Meter Unitt
UN-14
〈Front View〉
Configuration example
showing three UN-14 units
with BP-17
Accommodates a range of measurement microphones and various
preamplifiers including types with TEDS compliant input.
〈Rear View〉
Vibration Level Meter Unit
UV-15
〈Front View〉
Configuration example
showing three UV-15 units
with BP-17
Provides connectivity for piezoelectric accelerometers, accelerometers
with integrated preamplifier, and TEDS compliant accelerometers.
〈Rear View〉
Multi-Channel Sound/Vibration Measurement System Configuration Examples
■ UN-14 current consumption per unit: 140 mA ■ UV-15 current consumption per unit: 140 mA ■ UV-22 current consumption per unit: 240 mA
Sensors
◎Microphone
◎Microphone preamplifier(excluding UC-34P)
■ Link 1 to 16 units in any combination:
Sound Level Meter Unit UN-14 and
Vibration Level Meter Unit UV-15
■ Link up to 3 units for battery
powered operation with
Battery Pack Unit BP-17
■Link 1 to 16 units to
Interface Unit UV-22 Sensitivity setting range: -10.0 to -59.9 dB (dB re 1 V/Pa)
Combination
◎Piezoelectric accelerometer
◎Accelerometer with integrated preamplifier
◎TEDS compliant accelerometer with integrated preamplifier
Sensitivity setting range
:0.100 to 99.9 pC /(m/s 2)
:0.100 to 99.9 mV/(m/s 2)
UV-15
UV-15
UN-14
UV-15 UN-14
BP-17
UV-22
UV-15
UN-14
Configure a measurement system for up to 16 channels by linking the Sound Level Meter Unit UN-14
and Vibration Level Meter Unit UV-15. Each unit has its own display showing settings, measurement values,
and a bar graph indication. Adding the Interface Unit UV-22 allows connection to a computer for control of
settings and operation and transfer of measurement data.
■ Backlit LCD and LED warning indicators
■ Rack mount capability for shop floor or laboratory installations (JIS compliant rack CF-27 available as option)
■ Easy portability of sound level or vibration level units allows use in the field (with optional Battery Pack Unit BP-17)
UN-14 Specifications
Inputs
Number of measurement channels
Connectors
7-pin input connector
BNC connector
Frequency weighting
characteristics
Measurement
level range
1
For measurement microphone or preamplifier (max. input voltage ±10 V) (excl. UC-34P connection)
Microphone bias voltage +30 V, +60 V, +200 V
For CCLD compliant microphone or preamplifier (24 V 4 mA)
For TEDS compliant microphone (24 V 4 mA)
A, C, Z (JIS C 1509-1 Class 1 electrical characteristics)
A 30 to 128 dB (using UC-59, NH-17)
C 36 to 128 dB (using UC-59, NH-17)
Z 41 to 128 dB (using UC-59, NH-17) (HPF 20 Hz, LPF 20 kHz)
1 Hz to 80 kHz (20 Hz to 40 kHz ±0.5 dB) (1 Hz to 80 kHz ±3 dB)
Frequency range
Sensitivity setting
Setting range
Level range settings
-10.0 to 59.9 dB/Pa in 0.1 dB/Pa steps
6 settings (level range changes with sensitivity setting)
Sensitivity
-10.0 to -19.9
-20.0 to -29.9
-30.0 to -39.9
-40.0 to -49.9
-50.0 to -59.9
Time weighting
characteristics
Display
Display contents
Warning indications
Right-side LED
Left-side LED
Filters
HPF (attenuation -18 dB/oct,
-3 dB drop)
LPF (attenuation -18 dB/oct,
-3 dB drop)
Level range
70 dB to 120 dB in 10-dB steps
80 dB to 130 dB in 10-dB steps
90 dB to 140 dB in 10-dB steps
100 dB to 150 dB in 10-dB steps
110 dB to 160 dB in 10-dB steps
F, S, 10 ms (JIS C 1509-1 Class 1 electrical characteristics)
Segment-type LCD with backlight (constantly on)
Unit settings, instantaneous value (1-s cycle), bar graph (100-ms cycle)
LED x 2
Normally out. Lights up in red to indicate overload.
Master/Slave indication (when linked to UV-22). Normally out. Lights up to indicate Master operation
20 Hz, OFF
(user filter supported with UV-22)
20 kHz、
OFF
(user filter supported with UV-22)
Calibration signal output (for calibration of subsequent unit)
Sine wave 1 kHz ±2 %, output signal 0.5 V (RMS) ±2 %
AC output
+3.2 V ±1 %
DC output
Output
BNC connector
Output impedance 600 Ω
AC output
1 V (RMS) ±2 % at range full-scale point
Output voltage
Max. output voltage ±5 V (peak) (no overload)
80 dB or more (1 Hz to 80 kHz), 85 dB or more (20 Hz to 20 kHz)
Dynamic range
10 kΩ or more
Load impedance
Output impedance 50 Ω
DC output
+3.5 V±1 % at range full-scale point (0.5 V/10 dB)
Output voltage
Max. output voltage +5 V
40 dB or more (1 Hz to 80 kHz), 60 dB or more (20 Hz to 20 kHz)
Dynamic range
10 kΩ or more
Output impedance
Residual noise
Input converted residual noise
4 μV(RMS) or less (Z, 1 Hz to 80 kHz), 2 μV(RMS) or less (Z, 20 Hz to 20 kHz),
1.5 μV(RMS) or less (A, C)
Power supply
9 V to 15 V DC
Suitable AC adapter: NC-99 (for up to 16 units)
Battery Pack Unit BP-17
Automotive 12 V battery can also be used
Temperature/humidity range -10 ℃ to +50 ℃, max. 90 % RH (no condensation)
for operation
Dimensions and weight
150 (H) 36 (W) 179 (D) mm (without protruding parts), approx. 500 g
Accessories
Link plate x 1
■ Options
Model
Name
Measurement microphone
Preamplifier
7-p microphone extension cable
BNC-BNC cable
BNC-BNC coaxial cable
Link plate
Various
Various
EC-04 (2 m and up)
NC-39A
EC-90A (2 m and up)
UV160070
UV-15 Specifications
Inputs
Number of measurement channels
Connectors
Microdot connector
CCLD (Constant
Current Line Drive)
7-pin preamplifier connector
(connector type PROCEDURE-03)
Measurement modes and units
Display characteristics
Range selection
Sensitivity
0.100 to 0.999
Sensitivity
1.00∼9.99
Sensitivity
10.0∼99.9
Sensitivity settings
Setting range
Units
pC/(m/s2)
mV/(m/s2)
For piezoelectric accelerometer (max. input charge 100,000 pC)
For accelerometer with integrated preamplifier (24 V 4 mA)
For TEDS compliant accelerometer with integrated preamplifier (24 V 4 mA)
For connection of piezoelectric accelerometer via preamplifier
(VP-26A) (max. input voltage ±10 V)
ACC (acceleration): m/s2, VEL (velocity): mm/s, DISP (displacement): mm
RMS, EQ PEAK (RMS x √2), EQ P-P (EQ PEAK 2)
7 settings (range changes with sensitivity setting)
ACC (acceleration): 10, 30, 100, 300, 1 000, 3 000, 10 000
VEL (velocity): 10, 30, 100, 300, 1 000, 3 000, 10 000
DISP (displacement): 1, 3, 10, 30, 100, 300, 1 000
ACC (acceleration): 1, 3, 10, 30, 100, 300, 1 000
VEL (velocity): 1, 3, 10, 30, 100, 300, 1 000
DISP (displacement): 0.1, 0.3, 1, 3, 10, 30, 100
ACC (acceleration): 0.1, 0.3, 1, 3, 10, 30, 100
VEL (velocity): 0.1, 0.3, 1, 3, 10, 30, 100
DISP (displacement): 0.01, 0.03, 0.1, 0.3, 1, 3, 10
0.100 to 0.999 in 0.001 increments, 1.00 to 9.99 in 0.01 increments, 10.0 to 99.9 in 0.1 increments
Piezoelectric accelerometer
Accelerometer with integrated preamplifier, Accelerometer with integrated TEDS
compliant preamplifier, piezoelectric accelerometer connected via preamplifier (VP-26A)
Frequency range
ACC (acceleration)
VEL (velocity)
DISP (displacement)
Display
Display contents
Alarm indication
Right-side LED
Left-side LED
Options
1
1 Hz to 15 kHz (AC output tolerance ±5 %),
0.5 Hz to 30 kHz (AC output tolerance ±10 %)
3 Hz to 3 kHz (measurement value tolerance ±5 %)
3 Hz to 500 Hz (AC output tolerance ±10 %)
Segment-type LCD with backlight (constantly on)
Unit settings, instantaneous value (1-s cycle), bar graph (100-ms cycle)
LED×2
Normally out. Lights up in red to indicate overload
Master/Slave indication (when linked to UV-22). Normally out. Lights up to indicate Master operation
Filters
HPF (attenuation -18 dB/oct, 3 Hz, 5 Hz, 10 Hz, 15 Hz, 20 Hz, 30 Hz, 50 Hz, 100 Hz, 150 Hz, 200 Hz, OFF
(user filter supported with UV-22)
-10 % dB drop)
LPF (attenuation -18 dB/oct, 300 Hz, 500 Hz, 1 kHz, 1.5 kHz, 2 kHz, 5 kHz, 10 kHz, 15 kHz, 20 kHz, OFF
(user filter supported with UV-22)
-10 % dB drop)
Calibration signal output (for calibration of subsequent unit)
output
Sine
wave 80 Hz ±2 %
AC
1 V (RMS) ±2 % (RMS indication) , 1 V (peak) ±2 % (EQ PEAK indication),
Output signal
1 V (peak-to-peak) ±2 % (EQ P-P indication)
1V
DC output
Outputs
BNC connector 2
Output impedance 50 Ω
AC output
Output voltage accuracy ACC (acceleration) 1 V ±2 %, VEL (velocity) 1 V ±3 %,
DISP (displacement) 1 V ±5 %
(80 Hz full-scale)
Maximum output voltage ±10 V (peak) or more
Output impedance 50 Ω
DC output
Output voltage accuracy ACC (acceleration) 1 V ±2 %, VEL (velocity) 1 V ±3 %, DISP (displacement) 1 V ±5 %
Maximum output voltage 10 V or more
Residual noise
Input capacitance 1 000 pF, sensitivity 5.00 pC/(m/s2),
(representative characteristics) piezoelectric accelerometer, HPF OFF, LPF OFF, minimum range
ACC (acceleration) 0.01 m/s2 (RMS) or less, VEL (velocity) 0.1 mm/s (RMS) or less,
DISP (displacement) 0.0015 mm (RMS) or less
Power supply
9 V to 15 V DC, Suitable AC adapter: NC-99 (for up to 16 units)
Battery Pack Unit BP-17, Automotive 12 V battery can also be used
Temperature/humidity
-10 ℃ to +50 ℃, max. 90 % RH (no condensation)
range for operation
Dimensions and weight 150 (H) x 36 (W) x 179 (D) mm (without protruding parts), approx. 500 g
Accessories
Link plate x 1
■ Options
Name
Model
Piezoelectric accelerometer
Accelerometer cable
Vibration meter preamplifier
Vibration level meter/vibration meter accelerometer cable
BNC-BNC cable
Link plate
Various
Various
VP-26A
EC-02S (3 m and up)
NC-39A
UV160070
(One of the following is required for supplying power)
Links to UN-14 or UV-15.
Up to 3 units can be operated on battery power
■ NC-99: 100 to 240 V AC, 12 V DC, 5 A (for max. 16 units)
■ Size: 149 (H) x 480 (W) x 320 (D) mm
(AC adapter connection enables operation of 1 to 16 units)
■ IEC R14 (size "C") x 8
■ Continuous operation capability:
approx. 8hours*
(alkaline batteries, CHARGE-setting,normal operating)
approx. 6hours*
(alkaline batteries, CCLD-setting,normal operating)
*3 units connected, at 25 ℃ ambient temperature
(will differ according to environmental conditions and unit settings) 〈Front View〉〈Rear View〉
Battery Pack Unit
AC Adapter
Rack Mounting Base
BP-17
NC-99
CF-27(JIS compliant)
Interface Unit
UV-22
The UV-22 is a dedicated interface unit for use with the UN-14 and UV-15. Both USB and Ethernet interfaces are provided, allowing control
of the UN-14 and UV-15 from a computer. The supplied UV-22Viewer software makes it easy to establish settings for the UN-14 and UV-15
and check measurement results. High-pass filter and low-pass filter cutoff frequency (user filter *1) settings can also be made. When multiple
UN-14/UV-15 units are connected, the Master/Slave function simplifies operation. ※ The 2-channel charge amplifier UV-16 cannot be connected. *1 Can be set in 1/3 octave band steps within the specified frequency range.
UV-22Viewer
(supplied)
Startup screen
Measurement value/setup screen
UN-14 and UV-15 communication specifications
Settings control and check
(for UN-14 and UV-15)
For UN-14 only
For UV-15 only
Measurement values
UN-14/UV-15 interface
Number of connected units
Computer interfaces
USB
Connector
Ethernet
Temperature/humidity
range for operation
Power supply
〈Front View〉
Current consumption
Dimensions and weight
Supplied accessories
〈Rear View〉
Input selection, sensitivity, HPF, LPF, compensation
Frequency weighting, level range, time weighting
Measurement mode, range, display characteristics
Instantaneous value or max. value, every 100 ms
Up to a combined total of 16 UN-14/UV-15 units
USB 1.1 (one UV-22 per computer supported)
Mini B
10/100 Base-TX (one UV-22 per computer supported)
-10 ℃ to +50 ℃, max. 90 % RH
9 V to 15 V DC, Suitable AC adapter: NC-99, Battery Pack Unit BP-17,
automotive 12 V battery can also be used
Approx. 240 mA (12 V DC, LAN operation)
150(H) × 36(W) × 179(D) mm, approx. 500 g UV-22Viewer software x 1 (CD-ROM), USB cable
Example for multi-channel sound/vibration measurement system
UV-22 UV-15 UN-14
ETHERNET
* Specifications
ISO 14001 RION CO., LTD.
ISO 9 0 0 1 RION CO., LTD.
subject to change without notice.
Distributed by:
http://www.rion.co.jp/english/
3-20-41, Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan
Tel: +81-42-359-7888 Fax: +81-42-359-7442
This leaflet is printed with environmentally friendly soy ink on recycled paper.