ASCO Islatrol E 270, Islatrol IC+/LRIC+ 275, Islatrol IE 277 Surge Protective Device Installation & Operation Manual
Below you will find brief information for Surge Protective Device Islatrol E 270, Surge Protective Device Islatrol IC+/LRIC+ 275, Surge Protective Device Islatrol IE 277. These devices are designed to protect your equipment from damaging voltage transients and surges. They offer a variety of features, including Active Tracking™ technology for excellent noise reduction, high energy current diverters for protection against the full spectrum of voltage transients and surges, and a variety of connection types and enclosure options to meet your specific needs. The unit includes alarm contacts for remote indication of protection status. The installation is relatively simple, but it is important to follow the provided instructions to ensure proper operation and maximum system performance. Make sure the total current draw on the unit from all loads does not exceed the rated current.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Surge Protective Devices Installation & Operation Manual Model 270 Islatrol E Series - DC (DC Voltage EMI/RFI Noise Filter & SPD) Model 275 Islatrol IC+/LRIC+ Series (AC Voltage EMI/RFI Noise Filter & SPD) Model 270 Model 275 Model 277 Model 277 Islatrol IE Series (AC Voltage EMI/RFI Noise Filter & SPD) ASCO SERIES 200 power line filters offer the original Active Tracking™ technology to guard against commonly occurring, but very damaging, lower energy transients and offers excellent noise reduction. The Model 277 & Model 275 combine rugged, high energy current diverters with the Active Tracking™ Filter to provide protection against the full spectrum of voltage transients and surges. INSTALLATION DANGER! ONLY QUALIFIED PERSONNEL SHOULD INSTALL OR SERVICE THIS SYSTEM. ELECTRICAL SAFETY PRE-CAUTIONS MUST BE FOLLOWED WHEN INSTALLING OR SERVICING THIS EQUIPMENT. TO PREVENT RISK OF ELECTRICAL SHOCK, TURN OFF AND LOCK OUT ALL POWER SOURCES TO THE UNIT BEFORE MAKING ELECTRICAL CONNECTIONS OR SERVICING. DANGER! SEULEMENT LE PERSONNEL QUALIFIÉ DOIT INSTALLER OU MAINTENIR CE SYSTÈME. DES PRÉCAUTIONS DE SÉCURITÉ EN ÉLECTRICITÉ DOIVENT ÊTRE SUIVIS LORS DE L’INSTALLATION OU DE LA MAINTENANCE DE CET EQUIPEMENT. POUR EVITER TOUT RISQUE DE CHOC ÉLECTRIQUE, DÉBRANCHEZ ET VEROUILLER TOUTES LES SOURCES D’ ALIMENTATION DE CET EQUIPEMENT AVANT DE LE BRANCHER OU LE MAINTENIR. Proper installation is required for maximum system performance. Read the following information to assure a quality installation. These instructions do not replace national or local electrical codes. Environment – For use indoors, in an ambient temperature of -40°C to +50°C, with a relative humidity 0% to 95% (non-condensing). Maximum Current Capability – The total current draw for all loads that a model may continuously handle is given in the MODEL NUMBER CONFIGURATION table found on the next page. Overloading the unit can permanently damage the device. Nominal Voltage – The nominal operating voltage for each model is given in the MODEL NUMBER CONFIGURATION table found on the next page. Failure to use the unit at its rated voltage can permanently damage the unit or provide inadequate surge protection. Supplemental Enclosures - All units provided with exposed terminal blocks must be installed inside an enclosure and located so as to prevent accidental contact with terminals during maintenance or servicing. Summary Alarm Contacts (Model 277 only) – Summary alarm Form C (1 N.O. and 1 N.C.) relay contacts rated 125VAC, 5A max. are provided for remote indication of protection status. Connections may be made to these terminals on the unit using 18 AWG conductors. Grounding - Input and output ground terminals (if provided) must be connected for proper operation. This grounding is not only required for safety, but also for equipment performance. Incorrect grounding can reduce or impede the operation of the unit. Line Cord Units (Model 275 only) – Plug unit into wall outlet and turn on power switch (if provided). For best results, plug equipment to be protected directly into the unit (do not use extension cords or power strips). Keep data cables as far away from power cords as possible. OPERATION These products are designed for years of trouble-free operation and require little or no operator intervention after installation. Should the unit not appear to be functioning properly and/or the indicator LED (if provided) is extinguished, check all connections, and assure the voltage is correct and that the total current draw on the unit from all loads does not exceed the rated current. If the unit still is not functioning properly, call ASCO Surge Protection at 800-237-4567. TROUBLESHOOTING If any of the diagnostic indicators indicates a problem (i.e. red LED ON, and/or green LED OUT), check all connections and voltages to the unit. If all connections are reliable, and proper voltages are supplied to the unit, call ASCO Surge Protection, Inc at 800-237-4567. Installation, Operation and Maintenance Manual 2 IO-30100 RevO 07-17 16 DIGIT MODEL NUMBER CONFIGURATION Model Configuration & Voltage Modes of Protection Max Current Capability Connection Type Enclosure Accessories 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 7 0 D 2 5 0 F 0 0 7 A N 2 N 0 F 0 1 5 J F 0 3 0 G F 0 5 0 L F 1 0 0 2 2 7 7 5 1 2 0 N F 0 0 2 N 3 2 4 0 L F 0 0 5 L C 4 8 0 L F 0 0 7 W L F 0 1 5 F 0 3 0 N 3 7 1 2 0 N F 0 0 3 2 4 0 L F 0 0 5 F 0 1 0 F 0 2 0 A A N 0 N 0 X KEY 270 275 277 Islatrol E Series (DC) 120N F002 2.5 Amps Max F003 3 Amps Max F005 5 Amps Max F007 7.5 Amps Max 240L 220, 230, 240VAC Single Phase (L,N,G or L1,L2,G) 480L 480VAC Single Phase (L1,L2,G) D250 0-250VDC (Pos,Neg) F050 50 Amps Max F100 100 Amps Max Islatrol IC+/ LRIC+ Series Islatrol IE Series 120VAC Single Phase (L,N,G) F010 10 Amps Max F015 15 Amps Max F020 20 Amps Max F030 30 Amps Max WIRE SIZING & FUSING/CIRCUIT BREAKER AMPACITY Device Maximum Current Capability Suggested Min. Wire Size (AWG) Suggested Fusing / Circuit Breaker Size F002 = 2.5 Amps Max F003 = 3 Amps Max F005 = 5 Amps Max F007 = 7.5 Amps Max F010 = 10 Amps Max F015 = 15 Amps Max F020 = 20 Amps Max F030 = 30 Amps Max F050 = 50 Amps Max F100 = 100 Amps Max 26 AWG 24 AWG 22 AWG 18 AWG 14 AWG 14 AWG 12 AWG 10 AWG 6 AWG 2 AWG 2.5 Amp 3 Amp 5 Amp 7.5 Amp 10 Amp 15 Amp 20 Amp 30 Amp 50 Amp 100 Amp A All Modes of Protection LC NEMA Line Cord/ G Type 4 Receptacle (metal) N2 2 Position Terminal Blocks NEMA J Type 4X (plastic) N3 3 Position Terminal Blocks N WL Wire Leads 0 Standard Open Style – SPD with Exposed Terminals X additional Options/ NEMA Accessories L Type 12 (metal) WIRE DIAGRAMS DC Voltage Units (pos, neg) Single Phase (L, N, G) units Single Phase (L1,L2,G) units Continued on Back Installation, Operation and Maintenance Manual 3 IO-30100 RevO 07-17 • For units provided with a ground connection, a green (with or without one or more yellow stripes) insulated grounding conductor identical in size, insulation material, and thickness to the grounded and ungrounded conductors must be installed (ref. NEC Table 250-95) and referenced back to an acceptable building earth ground. Attachment plugs, receptacles, etc. in the vicinity of the filter must be of a grounding type, with the grounding conductors serving them connected to an acceptable building earth ground. • Terminals, lugs, and connectors used in installation must be suitable for the material of the conductors. Conductors of dissimilar metals shall not be intermixed in a terminal or splicing. Scan this QR code to learn more about ASCO Surge Protection. 14550 58th Street North Clearwater, Florida 33760 P (800) 237-4567 P (727) 535-6339 F (727) 539-8955 E [email protected] While every precaution has been taken to ensure accuracy and completeness in this literature, ASCO assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The ASCO and ASCO Power Technologies marks are owned by Emerson Electric Co. or its ailiates and utilized herein under license. ©2017 ASCO Power Technologies. All Rights Reserved. IO-30100 RevO 07-17
advertisement
Key Features
- Active Tracking™ technology
- High energy current diverters
- Summary alarm contacts
- Various connection types
- Multiple enclosure options
- Installation instructions included