Normal PDU - IEC Sockets Single Phase
IEC Single Phase Model
1
1Ph, 230V, 32A, 1U standard rack mount power distribution unit with 12 X C13, Inlet
Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2
Circuits - PDU Rating 7.3KVA/Rear feed-3Mt/ Black
PDU-H-1-IEC-F12-X4-Y2-Z0
2
1Ph, 230V, 32A, 1U standard rack mount power distribution unit with 8 X C19, Inlet
Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E),16A MCB X 2
Circuits - PDU Rating 7.3KVA/Rear feed-3Mt/ Black
PDU-H-1-IEC-G8-X4-Y2-Z0
3
1Ph, 230V, 32A, 1U standard rack mount power distribution unit with 4 X C13 & 4
XC19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A
MCB X 2 Circuits - PDU Rating 7.3KVA/Rear feed-3Mt/ Black
PDU-H-1-IEC-F4-G4-X4-Y2-Z0
4
1Ph, 230V, 32A, 2U standard rack mount power distribution unit with 20 X C13 & 4
XC19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A
MCB X 2 Circuits - - PDU Rating 7.3KVA/Rear feed-3Mt/ Black
PDU-H-1-IEC-F20-G4-X4-Y2-Z0
Note : Other Socket configuration available on request
Version - 2016 - 001
Rack Power & Electronics
Normal PDU - IEC Sockets Single Phase
Rack Power & Electronics
Normal PDU - IEC Sockets Single & Three Phase
IEC Sockets Single & Three Phase
1
1Ph, 230V, 32A, Zero U standard rack mount power
distribution unit with 12 X C13, Inlet Plug (Not
Installed, Recommended IEC30932A 2P+E), 16A
MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed3Mt/ Black
PDU-V-1-IEC-F12-X4-Y4-Z0
2
1Ph, 230V, 32A, Zero U standard rack mount power
distribution unit with 12 X C19, Inlet Plug (Not
Installed, Recommended IEC30932A 2P +E), 16A
MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed3Mt/ Black
PDU-V-1-IEC-G12-X4-Y4-Z0
3
1Ph, 230V, 32A, Zero U standard rack mount power
distribution unit with 12X C13 & 4 X C19, Inlet Plug
(Not Installed, Recommended IEC30932A 2P+E),
16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom
feed-3Mt/ Black
PDU-V-1-IEC-F12-G4-X4-Y4-Z0
4
1Ph, 230V, 32A, Zero U standard rack mount power
distribution unit with 20 X C13 & 4 X C 19, Inlet Plug
(Inlet Plug Not Installed, Recommended IEC30932A
2P+E), 16A MCB X 2 Circuits - PDU Rating
7.3KVA/Bottom feed-3Mt/ Black
PDU-V-1-IEC-F20-G4-X4-Y4-Z0
IEC Three Phase Model
1
3Ph, 400V, 16A/Ph, Zero U standard rack mount
power distribution unit with 24 X C13, Inlet Plug
IEC30916A 4P +E, 16A MCB X 3 Circuits - PDU
Rating 11KVA/Bottom feed-3Mt/ Black
PDU-V-3-IEC-F24-X6-Y4-Z0
2
3Ph, 400V, 16A/Ph, Zero U standard rack mount
power distribution unit with 12 X C13 & 12 XC19,
Inlet Plug IEC30916A 4P +E, 16A MCB X 3 Circuits
- PDU Rating 11KVA/Bottom feed-3Mt/ Black
PDU-V-3-IEC-F12-G12-X6-Y4-Z0
3
3Ph, 400V, 32A/Ph, Zero U standard rack mount
power distribution unit with 18 X C13 & 18 XIEC 19,
Inlet Plug IEC30916A 4P +E, 16A MCB X 6 Circuits
-PDU Rating 22KVA/Bottom feed-3Mt/ Black
PDU-V-3-IEC-F18-G18-X7-Y4-Z0
4
3Ph, 400V, 32A/Ph, Zero U standard rack mount
power distribution unit with 30 X C13 & 6 XIEC 19,
Inlet Plug IEC30932A 4P +E, 16A MCB X 6 Circuits
- PDU Rating 22KVA/Bottom feed-3Mt/ Black
PDU-V-3-IEC-F30-G6-X7-Y4-Z0
Note : Other Socket configuration available on request