TS®100 PRO with PowerBT® Bridge Tap Detect

TS®100 PRO with PowerBT® Bridge Tap Detect
TS ®100 PRO with PowerBT ® Bridge Tap Detect
Cable Fault Finder, Toner, AC/DC Voltage & Bridge Tap Locator
As new services like IPTV, streaming
ThenewTS®100PROCableFaultFinder with
video, and high-speed FTTx become more
PowerBT™BridgeTapDetectnotonly provides
prevalent, so does customer demand for
open/shortcircuitdetection–to 8,000feet
network reliability, service and higher
(2.4kilometres)–butisalsoa telecomtech-
quality. However, reliability of these
nician’sfirstlineofdefense againstbridge
network services can be significantly af-
taps.Becausebridgetapsarea significant
fected by bridge taps.
sourceofDSLnetwork performanceproblems,
theyneedtobe identified andfixedquickly
Bridge taps are extra lengths of cable that
beforecausing customer attrition.TheTS100
can negatively affect the signal. Detecting
PROcan accurately locatemultiplebridge
bridge taps can be complicated and costly
tapsin secondsonup to3,200feet(975
but the TS100 PRO with PowerBT Bridge
metres)of cablewiththe touchofabutton.
Tap Detect allows users to locate multiple
bridge taps on up to 3,200 feet
Anessentialfive-in-onetool,theTS100PRO
(975 metres) of cable with simply the
alsogivesusersabuilt-intonerwithfive
touch of a button.
differenttonesandpatentedSmartTone®for
Open/short circuit detection – up to
8,000 feet (2,400 metres)
exactpairidentificationandreportsAC/DC
Key Customers:
voltagefromjustoneendofanytwo con-
• TelecommunicationsServiceProviders
ductorwires,telephonewires,security wires
• CableTelevisionOperators/MSOs
orcoaxcables.Thistime-saving multi-toolis
• Independent,Regional&RuralTelcos
soaffordableeverytechnician canhaveone.
• NetworkTechnicians
• Contractors
• NetworkInstallers
• MetropolitanNetworks
TS100 PRO Highlights:
• Characterizesyourcableinseconds
withthepushofonebutton
• Notrainingrequiredorconfusing
graphstointerpret
• Handheldandruggedlybuiltforthe
outdoorenvironment
• Idealforalllevelsoftechnicians
Features:
• BridgetapdetectionforxDSL
pre-qualification
» Reportslengthofmultiplebridgetaps–
upto3,200feet(975metres)
» Seespastbridgetapstotheend
ofthecable
• Long-distancetester–testsopensand
shortsupto8,000feet(2.4kilometres)
• PatentedSmartTone®tonegeneratorwith
fivedifferenttonesforexactpair
identification
• Built-inTDR(TimeDomainReflectometer)
• AC/DCvoltagedetection
• One-buttontesting
• Built-intoner
Bridge tap found at 945 feet /288 metres
Benefits:
• Affordablebridgetapdetection
• ImprovedDSLnetworkperformance
• Five-in-onetool;bridgetapdetector,
openandshortdetector,voltagedetector,
SmartTonewithfivedifferenttones
• Nocomplicatedsetuporexpertiserequired
• Nointerpretationoranalysesof
complexgraphs
Tolearnmorevisit,
www.flukenetworks.com/ts100pro
First Response TDR with Bridge Tap Detection
Technical Data
Specifications
Maximum Length
Representative Maximum
Cable Length
Minimum Length
Length Accuracy
8,000feet(2,438meters)oncertaincable
types,4,000feet(1,220meters)onmost
cabletypes,and500feet(152meters)on
cableswithhighloss.Thetestershows
-Errifthecableistoolongtobecorrectly
measured.
Toner Range
52,800feet(16,093meters)
SmartTone® Range
7,000feet(2,134meters)
Tone Injection
8,000feet(2,438meters):CAT-3TwistedPair
8,000feet(2,438meters):CAT-5TwistedPair
6,000feet(1,830meters):12/2ACWire
3,000feet(900meters):RG-6/UTVCoax
1,500feet(457meters):RG-174/UCoax
Approximately1kHzatanamplitudeof80%
ofbatteryvoltage.Variablefrequencyand
cadence.Tonecharacteristicschangeascable
conditionchangesto“normal-open”fromany
othercondition.
Voltage Measurements
Nominimumlength(canreadabridgetapat
0feet/meters).Minimumnon-zeroreadingis
2feetor1meter.
Range:0voltsACto115voltsAC;0voltsDC
to±150voltsDC
Accuracy:AC:±1%or±1voltAC(45Hzto65
Hz);DC:±1%or±1voltDC
High Voltage Detection
ACvoltagedetectedto115volts;DCvoltage
detectedto±150volts.
ACvoltage≥90voltsorDCvoltage≥100volts
causeshighvoltagewarningstoshowonthe
display.
Impedance Range
35Ωto330Ωwithauto-compensation
withinthisrange.Cableswithimpedances
outsidethisrangewillnotbeproperlytested
andmayproduceerraticorincorrectreadings.
±2feet(±0.6m)forcableslessthan10feet
(3m)
±5feet(±2m)forcableslongerthan10feet
(3m)andshorterthan200feet(60m)
±3%,±5feet(±2m)forcableslongerthan
200feet(60m)
Distance to Bridge Tap
0feetto3,200feet(975meters)
Minimum Length of
Bridge Tap
10%ofthedistancetothebridgetap–
dependentonthecablecharacteristics.
Temperature Range
Operating:32°Fto104°F(0°Cto40°C)
Storage:32°Fto131°F(0°Cto55°C)
Measurement Rate
Maximumof4completemeasurementsper
second,decreasingto2secondspermeasurementbasedoncablesizeanduniformity.
Humidity
Operating:20%to80%relativehumidity
Storage:0%to100%relativehumidity
VOP
Adjustablefrom20to99,savedinflash
memory.
Operating
Relative Humidity
80%maximumat86°F(30°C)
50%maximumat104°F(40°C)
Operating Altitude
9,843ftmax(3,000mmax)
Test Technology
TimeDomainReflectometry(TDR)with100Ω
driveimpedance,6vmaximumpulseheight.
Weight
1lb(454grams)
Cable Type
Virtuallyalltwoormoreconductorcables
Power
4AAalkalinebatteries
Reverse Battery Protection
Nodamagetothetesterwilloccurifthe
batteriesareinstalledbackwards.
Battery Life
35hours(typical)
Low Battery Indication
LEDdisplayalternatesbetweenLOandbAtt
whenthebatteryvoltagefallsbelow4.5v.
Maximum Output Voltage
4voltagepeak
Maximum Isolation Voltage
250voltsRMS
Dimensions
3.6cm)
Safety
IEC61010-1:2010;N10140
EMC:IEC/EN61326-1:2006
Certifications and
Compliance
PConformitéEuropéenne.Conformsto
relevantEuropeanUniondirectives.
$IEC/EN61010-1
CAN/CSA-C22.2No.1010.1-92+CSA-
C22.2No.1010.1B-97,UL/ANSI3111-1
;ConformstorelevantAustralianstandards.
Notes:
Patents 6160405, 6285195, 6323654, and 6509740.
Specifications subject to change without notice.
TS100 PRO Ordering Information
Model
Description
TS100-PRO-BT-TDR
TS100PROCableFaultFinderTDRKitwithBridge
TapDetection
LEAD-ABNP-100
Testleadwithangled-bed-of-nailsandpiercing
pin.CompatiblewiththeTS100andTS100PRO
CASE-TS100
TS100/TS100PROpouchwithFlukeNetworks’logo
LEAD-ALIG-100
Testleadwithalligatorclips.Compatiblewith
theTS100andTS100PRO
Fluke Networksoperatesinmorethan50countries
worldwide.Tofindyourlocalofficecontactdetails,
gotowww.flukenetworks.com/contact.
LEAD-ABN-100
Testleadwithangled-bed-of-nails.Compatible
withtheTS100andTS100PRO
©2011FlukeCorporation.
Fluke Networks
P.O.Box777,Everett,WAUSA98206-0777
PrintedinU.S.A.11/20114107036B
Was this manual useful for you? yes no