29 · 4 Module overview for applications with Han-Eco

29 · 4 Module overview for applications with Han-Eco
Module overview for applications with Han-Eco®
830 V
m²
Han D ®
001
101
Han ® RJ45 module
Han ® RJ45 modules
dule
for patch cable
for IDC
for patch cable
for IDC and preLink
Male module (M)
09 14 001 4623
Male module (M)
09 14 001 4623
Female module (F)
09 14 001 4721
Adapter for patch cables:
09 14 000 9966
Patch cable cat. 6:
09 47 474 71xx
RJ Industrial IDC:
09 45 400 1560
-
-
-
Female module (F)
09 14 001 4722
RJ45 female IDC:
09 14 545 1561
RJ45 female preLink:
09 14 008 4720
Han-Quintax ®
Han ® High Density Quintax
Han D ® Coax
Han E ® Coax
2 x 4*
09 14 002 3001
09 14 002 3101
2 x 8*
09 14 002 3001
09 14 002 3101
2 x Coax*
09 14 002 3001
09 14 002 3101
2 x Coax*
09 14 002 3001
09 14 002 3101
- 8 contacts
- Cat. 6A
- 10 Gbit/s
Part numbers
module
HanEco
Han ® GigaBit – Han ® MegaBit modules
V
m²
, Han E ®
041
141
Han-Quintax ® modules
Quintax module
Number of contacts
Male module (M)
Female module (F)
Insert
(Cable Ø ≤ 9.5 mm)
Data rate
Electrical data
Cross-section
Termination type
Male insert (M)
Female insert (F)
PE shielding termination
100 Mbit/s (Cat. 5e)
≤ 500 Mhz / 50 Ω
≤ 500 Mhz / 75 Ω
100 Mbit/s (Cat. 5e)
5 A / 50 V
16 A / 50 V
10 A / 50 V
10 A / 50 V
0.09 … 0.52 mm²
0.14 … 4 mm²
0.14 … 2.5 mm²
0.14 … 2.5 mm²
Crimp termination, Han D ® Crimp termination, D-Sub Crimp termination, Han D ® Crimp termination, Han E ®
09 15 004 3013
09 15 008 3013
09 15 001 3013
09 15 001 3023
09 15 004 3113
09 15 008 3113
09 15 001 3113
09 15 001 3123
Optional shielding termination to the hinged frame with the aid of Han-Quintax ® metal adapter 09 14 000 9915
Han ® GigaBit module
Han ® MegaBit module
Han ® MegaBit module
with 1 cable entry
Han ® Shielded module
09 14 001 3011
09 14 001 3111
09 14 001 3011
09 14 001 3111
09 14 001 3011
09 14 001 3111
09 14 001 3011
09 14 001 3111
Adapter Modul
Male module (M)
Female module (F)
Insert
(Cable Ø ≤ 14 mm)
Number of contacts
Data rate
Electrical data
Cross-section
Termination type
Shielding termination
Male insert (M)
Female insert (F)
Male insert (M)
Female insert (F)
8
20
2x4
8
1 Gbit/s (Cat. 5e)
2 x 100 Mbit/s (Cat. 5e)
10 Gbit/s (Cat. 6A)
4 A / 32 V
5 A / 50 V
10 A / 50 V
10 A / 50 V
0.09 … 0.52 mm²
0.09 … 0.52 mm²
0.14 … 2.5 mm²
0.14 … 2.5 mm²
Crimp termination, D-Sub Crimp termination, Han D ® Crimp termination, Han D ® Crimp termination, D-Sub
2 x crimp flange
Crimp flange
Crimp flange
Crimp flange
09 14 008 3011
09 14 008 3016
09 14 008 3021
09 14 020 3013
09 14 008 3111
09 14 008 3116
09 14 008 3121
09 14 020 3113
with PE shielding termination with PE shielding termination with PE shielding termination
09 14 008 3012
09 14 008 3017
09 14 008 3022
09 14 008 3112
09 14 008 3117
09 14 008 3122
Serial Bus modules
Han D-Sub module
29
·
4
Number of contacts
9 + shielding
Datenrate
12 Mbit/s (Profibus)
Electrical data
5 A / 50 V
Cross-section
0.09 … 0.52 mm²
Termination type
Crimp termination, D-Sub
Male module (M)
09 14 009 3001
Female module (F)
09 14 009 3101
* Double module, requires two places in the frame
Han ® USB module
Han ® FireWire module
8
5 Gbit/s (USB 3.0)
1 A / 50 V
6
400 Mbit/s (IEEE 1394a)
1 A / 50 V
USB patch cable
FireWire patch cable
09 14 001 4601
09 14 001 4703
09 14 001 4611
09 14 001 4711
for more technical details see chapter 06
Removal tools 09 99 000 0331, 09 99 000 0828 and 09 99 000 0842 see chapter 90
* Take care of the wiring space! Choose inner positions.