Conettix D6680 Ethernet Network Adapter
Intrusion Alarm Systems | Conettix D6680 Ethernet Network Adapter
Conettix D6680 Ethernet Network Adapter
www.boschsecurity.com
The Conettix D6680 Ethernet Network Adapter is a
two-channel network adapter. The D6680 connects the
Conettix D6600 Communications Receiver/Gateway
RS-232 Data Port to an Ethernet LAN/WAN. One
adapter is required for each D6600 serial port with a
direct connection to a data network (LAN/WAN).
u
Two channel adapter
u
Network interface
u
Serial interface
Region
Certification
USA
UL
FM
Certifications and approvals
Install the Conettix D6600 Communications Receiver/
Gateway in accordance with NFPA 70, NFPA 72 and
the local Authority Having Jurisdiction (AHJ). The
Conettix D6680 Ethernet Network Adapter is suitable
for Central Station Protective Signaling when it is
installed and used in compliance with NFPA 72 and
ANSI/NFPA 70. Installation limits for Digital Alarm
Communicator Receivers (DACR) are under the
jurisdiction of the user’s local authority.
For UL Listed Fire Installations, equipment between
Ethernet Interface Modules and the D6680 is required
to be UL Listed Information Technology Equipment.
AMCX: Central Station Alarm Units
(UL1610, UL1635), UOXX: Control Unit
Accessories, System (UL864, 9th edition)
CSFM
7300-1615:0179 7300 -- FIRE ALARM
CONTROL UNIT ACCESSORIES/MISC.
DEVICES
Installation/configuration notes
Compatibility Information
Receivers:
Conettix D6600 Communications Receiver/
Gateway
Location and Enclosures
The D6680 must be installed in the same room as the
D6600 and within 15.2 m (50 ft) of the D6600.
Required for UL Central Station Protective Signaling,
the D6680 must be mounted in a separate enclosure
such as the AE1 (gray) or the AE2 (red).
2 | Conettix D6680 Ethernet Network Adapter
Parts included
Quantity
Component
1
Serial cable
Flow Control:
XON/XOFF
CTS/RTS
Management:
HTTP (internal web server)
SNMP (read only)
Serial login
Telnet login
System Software :
Flash ROM standard. Downloads from a
TCP/IP host (TFTP) or over serial port.
Diagnostic LEDs:
Network Transmit, Network Receive,
Good Link, Collisions, Channel 1 Status,
Channel 2 Status, and Diagnostic
Compatibility:
Ethernet: v2.0/IEEE 802.3
Conettix D6600 Communications
Receiver/Gateway
Technical specifications
Electrical
Power Requirements:
9 VDC to 30 VDC, or 9 VAC to 25 VAC
External adapter included.
Power Consumption:
3W
AC Current Required:
UPS Standby Current:35 mA
Power Input:
AC nominal operating range 120 VAC or
240 VAC
AC maximum operating range 100 VAC to
240 VAC ~ 50 Hz /60 Hz
0.2 A maximum
Standby Power:
An Uninterrupted Power Supply is
required for use with the D6680, when
used for UL FIRE Protective
Signaling Systems. A 60 hour minimum
UPS standby power supply is required for
UL Certification.
Mechanical
Environmental
Operating Temperature:
+5°C to +49°C (+41°F to +122°F)
Storage Temperature:
+40°C to +66°C (-40°F to +151°F)
Ordering information
Conettix D6680 Ethernet Network Adapter
Ethernet 120/240 VAC adapter for use with the
Conettix D6600 Communications Receiver/Gateway.
Order number D6680-E120
Unit Dimensions:
16.5 cm x 11.3 cm x 36 mm (6.5 in. x
4.46 in. x 1.39 in.)
Enclosure Dimensions:
31.8 cm x 36.8 cm x 76 mm (12.5 in. x
14.5 in. x 3 in.)
The enclosure is manufactured from 1.0
mm (20 Gauge), cold-rolled steel. A keyed
lock is included.
Weight:
0.48 kg (1.1 lb)
Protocols Supported:
ARP, UDP, TCP, Telnet, ICMP, SNMP,
DHCP, TFTP, HTTP, BootP and ECHO
Serial Connectors:
DB25: RS-232/RS-322/RS-485 serial
port with DCE configuration
DB9: RS232 serial port with DTE
configuration
Network Connectors:
10BASE-T or 10BASE-FL
LAN/WAN: RJ-45 Modular Jack (Ethernet)
Ethernet Cable:
Category 3 or better unshielded twisted
pair. Maximum length 100 m (328 ft).
RS-232 Cable:
Maximum length 15 m (50 ft).
Data Rates:
Serial speed ranging from 300 bps to
115.2 kbps.
Serial Line Formats:
Characters: 7 or 8 data bits
Stop bits: 1 or 2
Parity: Odd, even, none
Modem Controls:
RTS, CTS, DSR, DCD, DTR
3 | Conettix D6680 Ethernet Network Adapter
Represented by:
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
© Bosch Security Systems 2013 | Data subject to change without notice
2668390411 | en, V2, 01. Oct 2013
Asia-Pacific:
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
China:
America Latina:
Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
201 Building, No. 333 Fuquan Road
Via Anhanguera, Km 98
North IBP
CEP 13065-900
Changning District, Shanghai
Campinas, Sao Paulo, Brazil
200335 China
Phone: +55 19 2103 2860
Phone +86 21 22181111
Fax: +55 19 2103 2862
Fax: +86 21 22182398
latam.boschsecurity@bosch.com
www.boschsecurity.com.cn
www.boschsecurity.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising